Extron electronic Network Card HSA 200S User Manual

Users Manual  
HSA 200S & HSA 200SE  
HSA 200C & HSA 200CE  
HSA 222S & HSA 222C  
Hideaw ay Surface Access Products  
68-695-01 Re v. H  
08 08  
© 2008 Extron Electronics. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ta b le o f Co n t e n t s  
Ch a p t e r 1 • In t ro d u ct io n .......................................................... 1-1  
Ab o u t t h e Hid e a w a y Su rfa ce Acce ss Pro d u ct s ....... 1-2  
About the Extender board line driver .................................. 1-4  
Fe a t u re s ...................................................................................... 1-5  
All models .............................................................................. 1-5  
HSA 200CE and HSA 200SE models only .............................. 1-5  
Ch a p t e r 2 • In st a lla t io n ............................................................. 2-1  
In st a lla t io n Ove rvie w .......................................................... 2-2  
Pre p a rin g t h e Ro u t in g Te m p la t e ................................... 2-3  
Preparing the Table and Mounting the Enclosure ... 2-4  
Preparing the table with a router ........................................ 2-4  
Preparing the table with a hole saw  
(HSA 200C, HSA 200CE, or HSA 222C—US version only) ..... 2-6  
Installing the HSA enclosure (all).......................................... 2-6  
Un d e rsid e Fe a t u re s a n d Ca b lin g Co n n e ct io n s ....... 2-8  
All HSA 200 models only ....................................................... 2-9  
HSA 200C and HSA 200S (no Extender board) only ............ 2-9  
All HSA 200 and HSA 222 models ....................................... 2-10  
HSA 200CE and HSA 200SE (Extender board) only ............ 2-11  
Power connector wiring .................................................. 2-12  
Fro n t Pa n e l Co n n e ct o rs .................................................... 2-12  
Pre -in st a lla t io n Te st in g a n d Tro u b le sh o o t in g  
(HSA 200CE a n d HSA 200 SE m o d e ls o n ly) ............. 2-16  
If the image does not appear or there is no sound .......... 2-16  
If the image is not displayed correctly ............................... 2-16  
Ch a p t e r 3 • Ma in t e n a n ce a n d Mo d ifica t io n s ............ 3-1  
Re m o vin g a n d Re p la cin g t h e En clo su re .................... 3-2  
Re p la cin g t h e Be ze ls ............................................................ 3-3  
Re p la cin g t h e Ga s Lift ......................................................... 3-8  
Ad ju st in g t h e To p Pa n e l ................................................... 3-13  
HSA 200/222 Series • Table of Contents  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ta b le o f Co n t e n t s, co n t ’d  
Ap p e n d ix A • Re fe re n ce In fo rm a t io n ............................ A-1  
Sp e cifica t io n s ......................................................................... A-2  
HSA Pa rt Nu m b e rs ................................................................ A-7  
In clu d e d Pa rt s ......................................................................... A-8  
Ro u t in g Te m p la t e s ............................................................... A-8  
Re p la ce m e n t Pa rt s ............................................................... A-8  
Acce sso rie s ............................................................................... A-8  
To p Pla t e Dim e n sio n s ......................................................... A-8  
HSA 200/222 Series Surface Access Products  
Ap p e n d ix B • Pa cka g in g fo r Sh ip m e n t .......................... B-1  
All trademarks mentioned in this manual are the properties of their respective owners.  
Chapter One  
68-695-01 Re v. H  
08 08  
1
In t ro d u ct io n  
About the Hideaway Surface Access Products  
Features  
HSA 200/222 Series • Table of Contents  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ab o u t t h e Hid e a w a y Su rfa ce Acce ss Pro d u ct s  
The Extron Hideaway HSA 200 series and HSA 222 series are  
furniture-mounted, architectural solutions for inconspicuous  
computer video and/ or network access and control.  
The HSA 200C (figure 1-1) and HSA 200S (figure 1-2) provide:  
One standard grounded AC receptacle  


The US versions have US power receptacles  
Fig u re 1-2 — HSA 200S h id e a w a y e n clo su re  
The international versions have several different  
types of power receptacles available, including  
Universal, UK, French, Israeli, Australian, Indian,  
European, and Swiss receptacles.  
The HSA 222S (figure 1-3) and HSA 222C (US model only)  
provide:  
Two standard grounded AC receptacles  
The Universal AC outlet is fully compatible with  
Europlug, British, Indian, Danish, and Italian plug  
types. See the universal AC outlet guide on the Extron  
Web site, www.extron.com, for compatibility details on  
all plug types.  


The US versions have US power receptacles  
The international version has several different types  
of power receptacles available, including UK, French,  
Israeli, Australian, Indian, European, and Swiss  
receptacles.  
Two RJ-45 Category (CAT) 6 connectors (teminated in  
Two RJ-45 CAT 6 connectors  
accordance with the TIA/EIA 568 A standard)  
One 15-pin female HD computer video connector  
One 3.5 mm stereo female jack.  
Fig u re 1-3 — HSA 222S h id e a w a y e n clo su re  
The International HSA 222 is only available with a  
square top plate.  
For all models, cabling inside the enclosure runs the AC power  
line and RJ-45 signal lines from the HSA panel connectors to  
connectors on the bottom of the enclosure. For the HSA 200  
model, the computer video signal is routed to 5 BNC connectors  
on pigtails. On HSA 200S and HSA 200C units, the audio signal  
is sent to a 3-pole, 3.5 mm captive screw connector on a pigtail.  
On HSA 200SE and HSA 200CE units, the audio signal is sent to  
a 5-pole, 3.5 mm captive screw connector on the back of the unit.  
Fig u re 1-1 — HSA 200C h id e a w a y e n clo su re  
The HSA 200CE and HSA 200SE provide all of the HSA 200C  
or HSA 200S features plus:  
An Extender board, which sends the input signal a  
greater distance and converts the audio input to a  
balanced signal. See “About the Extender board line  
driver”, on the next page, for more details.  
HSA 200/222 Series • Introduction  
1-2  
HSA 200/222 Series • Introduction  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In t ro d u ct io n  
The installed enclosures fit nearly flush within a table or podium  
Fe a t u re s  
top (figure 1-4), storing the connectors out of the way and out of  
sight. To access the connectors, the user presses down on the  
top of the enclosure, releasing a mechanical latch. A gas lift tips  
the connectors into view.  
All m o d e ls  
UL/ CUL listing  
CSA certification  
Projector  
Easy access to connectors  
Durable mechanical movement and latching mechanism  
Available in a variety of surface finishes  
Extron HSA 200C  
Includes a variety of RJ-45 connector bezel colors: black,  
red, blue, orange, gray, white, ivory, yellow, and green  
Compact size  
Computer video and audio connections (HSA 200 models  
only)  
RJ-45 (CAT 6) network, data, or communications  
connections (teminated in accordance with the  
TIA/EIA 568 A standard)  
Extron  
HSA 200C  
Hideaway Surface  
Access Enclosure  
Grounded AC receptacle(s)  
HSA 200CE a n d HSA 200SE m o d e ls o n ly  
HSA 200CE and 200SE models include an Extender line driver  
board, which provides several features not available on the  
standard models.  
Mounted  
Through a Table  
or Podium  
Signal boosting ability — The gain/ peaking adjustment  
increases video signal voltages to compensate for signal  
degradation caused by long cables. The Extender board  
can send a high resolution signal up to 250 feet (76.2 m)  
through Extrons BNC-5 Mini HR cable.  
Fig u re 1-4 — HSA 200C a p p lica t io n  
Sync restoration — Each Extender board restores low  
level sync voltages found on many laptops (as low as two  
volts) to normal TTL levels.  
Ab o u t t h e Ext e n d e r b o a rd lin e d rive r  
Stereo audio — Unbalanced stereo audio inputs can be  
output as balanced or unbalanced stereo audio.  
The Extron Extender board in the HSA 200CE and 200SE is a  
one-input VGA – UXGA/ VESA line driver with audio. It boosts  
the video signal between a laptop or desktop computer and a  
monitor or projector. It has a 300 MHz (-3 dB) video bandwidth.  
The Extender accepts one computer-video input and one stereo  
audio input, and features one buffered VGA-type RGB output  
and one stereo audio output. With an optional Mac/ VGA  
adapter, the Extender board can also buffer Macintosh signals.  
HSA 200/222 Series • Introduction  
1-4  
HSA 200/222 Series • Introduction  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
In t ro d u ct io n  
HSA 200/222 Series Surface Access Products  
Chapter Tw o  
2
In st a lla t io n  
Installation Overview  
Preparing the Routing Template  
Preparing the Table and Mounting the Enclosure  
Underside Features and Cabling Connections  
Front Panel Connectors  
Pre-installation Testing and Troubleshooting  
(HSA 200CE and HSA 200SE Models Only)  
HSA 200/222 Series • Introduction  
1-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In st a lla t io n  
In st a lla t io n Ove rvie w  
Pre p a rin g t h e Ro u t in g Te m p la t e  
Install and set up the HSA surface access enclosures as follows:  
Extron provides a metal template for each HSA model at no  
charge. Appendix A lists the HSA 200 and HSA 222 template  
part numbers. Extron recommends using this template as a  
guide to cut the hole in the table where the HSA will be  
installed.  
If you have an unprepared mounting template, prepare  
the template. See “Preparing the Routing Template” in  
this chapter.  
1
If desired, install the optional RJ-45 to RJ-11 conversion  
kit(s) to replace one or more RJ-45 connectors with RJ-11  
connectors. Refer to the appropriate RJ-45 to RJ-11  
Conversion Kit manual, for either the HSA 200 models or  
the HSA 222 models.  
2
The metal routing template is reusable. Do not discard  
this template when the installation is complete. Save it  
for installing future HSA enclosures of the same size.  
1.  
Cut 1/ 2" x 4" strips of soft, finished lumber long enough to  
span the distance between the desired installation location  
on the mounting surface and the edges of the mounting  
surface (figure 2-1).  
If desired, install the optional flexible conduit kit to  
replace the removable AC power cord. Refer to the  
Flexible Conduit Kit manual.  
3
4
Width of Mounting Surf  
ace  
Cut a hole in the surface where the enclosure will be  
installed and install the enclosure. The screw clamps  
secure the enclosure to the tabletop. See “Preparing the  
Table and Mounting the Enclosure” in this chapter.  
Mounting  
Surface  
Edge  
Minimum  
4 Screws  
Run all cables necessary to support the AC power,  
RJ-45, and (for HSA 200 model only) video and audio  
connectors. Leave enough slack in the cables to connect  
them to the underside of the enclosure.  
5
6
Wood  
Strips  
Turn off all of the equipment to be connected. Ensure that  
the equipment connected to the RJ-45, video, and audio  
connectors are all turned off and disconnected from the  
power source.  
Wood Strip  
Height  
4" / 10.2 cm  
Connect the power, video, audio, and RJ-45 cables to the  
underside of the enclosure. See “Underside Features and  
Cabling Connections” in this chapter.  
7
8
Routing Template  
Mounting  
Surface  
Edge  
On HSA 200SE and HSA 200CE models, set the gain  
Wood Thickness  
0.5" / 1.3 cm  
switch.  
Connect and turn on the input and output devices.  
9
Fig u re 2-1 — Pre p a re d m o u n t in g t e m p la t e a sse m b ly  
For HSA 200SE and HSA 200CE model installations, the  
picture should now appear and sound should be audible.  
If not, ensure that all devices are plugged in and receiving  
power. Check the cabling and gain setting, and make  
adjustments as needed.  
10  
These strips raise the routing template above the mounting  
surface to provide room for the routers collar, protect the  
mounting surface, and extend the reach of the routing  
template so that it can be clamped to the edge of the surface.  
Peel the protective coating from the top surface.  
11  
2.  
Using four or more short wood screws, secure the  
mounting template to the lumber strips.  
Do not allow the wood screws to protrude through  
the bottom of the wooden strips. Protruding screws  
will mar the table when the template is used.  
CAUTION  
HSA 200/222 Series • Installation  
2-2  
HSA 200/222 Series • Installation  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In st a lla t io n , co n t ’d  
Preparing the Ta b le and Mounting the Enclosure  
The preferred and recommended method for preparing the  
table is to use the appropriate Extron routing template and a  
router. The templates are available at no cost; see the part  
numbers for the templates in appendix A, “Reference  
Information”.  
For an HSA 200C, HSA 200CE, or HSA 222C unit (US version  
only), another preferred method is to use a 6" hole saw.  
Alternatively, for any model, you can use a paper cut-out  
template (see a ppendix A, “Reference Information”) and a  
sabre saw or keyhole saw, but this method is not recommended.  
The opening in the table for the HSA enclosure  
should be cut only by licensed and bonded  
craftspeople. Exercise care to prevent scarring or  
damaging the furniture.  
CAUTION  
The routing templates for the various HSA models  
are not interchangeable. If you use the wrong  
template, you will cut an improperly-sized hole. If  
you use a larger template than required, the cut will  
result in gaps in the table surface on either side of  
the enclosure.  
Fig u re 2-2 — Cu t t in g t h e o p e n in g w it h a ro u t e r  
(e xa m p le )  
4.  
Using a router with a 5/ 8" (or 16 mm) outside diameter  
guide bushing and a 1/ 2" (or 12 mm or 12.7 mm)  
diameter straight router bit, carefully cut the opening in  
the table surface (figure 2-2).  
The surfaces of the HSA enclosure have screws and  
other protruding hardware that could damage fine  
furniture. Do not rest the enclosure on unprotected  
furniture.  
Wear safety glasses when operating the router.  
Failure to comply can result in eye injury.  
Pre p a rin g t h e t a b le w it h a ro u t e r  
5.  
Remove the clamps and the routing template.  
1.  
Locate the desired mounting location on the tabletop or  
The routing template is reusable. Do not discard the  
template when the installation is complete. Save it to  
install other HSA products of the same size.  
other installation surface. Mark the location.  
2.  
Place the mounting template assembly on the table,  
centered on the mounting location. Angle the template for  
the optimum positioning. If necessary, use a square to  
ensure that the template is properly positioned. Extron is  
not responsible for improperly-positioned HSA products.  
Ensure that only the wooden strips contact the  
furniture. Failure to do so may mar the furniture.  
CAUTION  
3.  
Once the template assembly is positioned properly, secure  
the assembly to the table with clamps (figure 2-2).  
HSA 200/222 Series • Installation  
2-4  
HSA 200/222 Series • Installation  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
In st a lla t io n , co n t ’d  
2.  
Remove the plastic strips that protect the corners of the  
enclosure. If a sticky residue remains, remove it with an  
appropriate metal cleaning product.  
Pre p a rin g t h e t a b le w it h a h o le sa w (HSA 200C,  
HSA 200CE, o r HSA 222C—US ve rsio n o n ly)  
1.  
Locate the desired mounting location on the tabletop or  
other installation surface. Mark the 6" circle, then find the  
center and mark it as well.  
Do not use isopropyl alcohol or other solvents to clean  
the HSA. Strong solvents will ruin some finishes.  
CAUTION  
3.  
4.  
Carefully lower the HSA enclosure into the hole to test the  
fit. If necessary, remove the enclosure and use a file or  
rasp to enlarge or smooth the edges of the opening.  
Wear safety glasses when operating the hole saw.  
Failure to comply can result in eye injury.  
2.  
Using a 6" hole saw on a portable drill, cut the mounting  
hole at the desired location (figure 2-3). Extron is not  
responsible for improperly positioned HSA products.  
From the underside of the table, reinstall the screw clamps  
on the enclosure at a height at which the clamp will reach  
the underside of the tabletop (figure 2-4).  
Use a portable drill with sufficient power for the 6"  
hole saw. Exercise caution when handling the drill  
and hole saw. Care should be taken to protect the  
surface of the tabletop, podium, or other mounting  
surface from damage.  
CAUTION  
Figure 2-4 shows an HSA 200 installation. Except for  
the video and audio connectors, the HSA 222 installation  
is identical.  
Extron  
HSA 200  
C
A
T
6
Hideaway Surface  
Access Enclosure  
Output BNC  
Connectors  
(HSA 200 models only)  
Mounting  
Surface  
Fig u re 2-3 — Cu t t in g t h e o p e n in g w it h a h o le sa w  
Screw Clamp  
In st a llin g t h e HSA e n clo su re (a ll)  
Power Cord  
1. Remove the screw clamps (2) on the sides of the enclosure.  
Display BNC  
Connectors  
(HSA 200 models only)  
2 RJ-45 Connectors  
Audio Cable  
(HSA 200 models only)  
The flanged edges of the top of the surface enclosure  
are bevelled to an ultra-fine thickness of less than  
0.04 (4/100)" (approximately 1 mm), and are  
therefore very sharp. These edges are also soft and  
may be easily nicked or bent. Exercise caution  
when handling and mounting the enclosure.  
Mishandling may result in injury to the installer or  
damage the appearance of the enclosure.  
CAUTION  
Fig u re 2-4 — Mo u n t in g t h e HSA 200 o r HSA 222  
e n clo su re  
HSA 200/222 Series • Installation  
2-6  
HSA 200/222 Series • Installation  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In st a lla t io n , co n t ’d  
5.  
Snugly tighten the Philips head screws on the screw  
clamps to secure the enclosure to the surface.  
All HSA 200 m o d e ls o n ly  
AC power outlet — Use this AC connector to:  
1
Overtightening the Philips head screws on the screw  
clamps can bend the clamps horizontal flange.  
CAUTION  
Plug in an external power supply to power the Extender  
board on the HSA 200CE or HSA 200SE.  
6.  
7.  
Tighten the locking thumbscrews on the screw clamps to  
lock the clamp in position.  
Provide AC power (5 amps max.) for loop through to one  
additional HSA 200 unit.  
Peel any remaining protective coating from the enclosure.  
Plug in a projector or other display device.  
This outlet is a US-style power outlet on both the US/  
domestic and international HSA 200 models. The power  
output is the same voltage and frequency as the power  
input.  
Un d e rsid e Fe a t u re s a n d Ca b lin g Co n n e ct io n s  
Figure 2-5 shows the under-table connectors and other features  
that present on HSA 200CE models. Other HSA 200 and  
HSA 222 models have a subset of the same or similar features.  
RGBHV video output — Connect the BNC cable from the  
projector, plasma screen, or other display device to these female  
BNC connectors.  
2
HSA 200C and HSA 200S (no Extender board) — The output  
from these connectors is an unbuffered pass-through from the  
front panel VGA input.  
HSA 200CE and HSA 200SE (Extender board) — The output on  
MEDIUM  
NORMAL  
unity gain  
MAXIMUM  
peaking  
gain POWER  
9-18 VDC  
peaking  
&
gain  
&
AUDIO  
R
R
L
L
these connectors is buffered by the Extender board.  
4
1
HSA 200C a n d HSA 200S (n o Ext e n d e r b o a rd ) o n ly  
*
On HSA 200 models with no Extender board, the audio  
connection is part of the pigtail (figure 2-6).  
Back View  
8
*
2
11●  
* HSA 200 Models Only  
*
13●  
HSA 200CE/HSA 200SE  
9
Units Only  
HSA 200S/HSA 200C  
10●  
7
12●  
3
(no Extender board) units only  
Fig u re 2-6 — HSA 200S a n d HSA 200C a u d io co n n e ct o r  
Audio output connection — This 3-pole direct insertion  
terminal outputs unbalanced audio, passed through from the  
front panel. Figure 2-7 shows how to wire the connector.  
3
5
Unbalanced Output  
Tip (L)  
Sleeve/Ground  
Tip (R)  
Bottom View  
Fig u re 2-7 — Un b u ffe re d , u n b a la n ce d a u d io  
co n n e ct o r w irin g  
6A 6B  
Fig u re 2-5 — HSA 200CE u n d e r-t a b le fe a t u re s  
HSA 200/222 Series • Installation  
2-8  
HSA 200/222 Series • Installation  
2-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
In st a lla t io n , co n t ’d  
All HSA 200 a n d HSA 222 m o d e ls  
Latch locking screws — These screws secure the latching  
mechanism to the enclosure. They must be loosened in order to  
adjust the top surface (see “Adjusting the Top Panel” in  
8
7
Screw clamp bracket/screw clamp — These two brackets/  
4
clamps hold the enclosure firmly in place in the mounting hole.  
chapter 3) with the top surface adjustment screw  
.
AC power input connection — Connect this cord to the power  
source.  
5
Top surface adjustment screw — After loosening the latch  
8
7
locking screws  
, adjust the top surface of the tilt up panel with  
this screw. Tighten the latch locking screws after adjustment.  
For US-domestic versions, this power cord is  
permanently connected to the HSA.  
Connect the power cord to a 125VAC, 60 Hz,  
5A power source.  
Gas lift mounting plate — The lower end of the gas lift is  
attached to this plate. The plate must be detached from the  
enclosure in order to remove the gas lift.  
9
For international versions, this power cord is a  
removable IEC power cord. Connect the cord  
to a 220-240V, 50/60 Hz, 5A power source.  
HSA 200CE a n d HSA 200SE (Ext e n d e r b o a rd ) o n ly  
Audio output connection — This 5-pole direct insertion  
terminal outputs unbalanced or balanced audio. Figure 2-9  
shows how to wire the connector.  
10  
You can replace this connector with an optional Extron HSA 200/  
HSA 222 Flexible Conduit Adapter kit (part #70-229-01).  
Unbalanced Output  
Tip  
See Caution  
Sleeve (s)  
Tip  
Balanced Output  
Tip  
Ring  
Sleeve (s)  
RJ-45 connectors — Plug one end of a CAT 5 or CAT 6 twisted  
pair (TP) cable into each of these RJ-45 female connectors.  
Connect the other end to an appropriate telecommunications or  
data network or to an Extron TP product.  
6
Tip  
Ring  
See Caution  
All RJ-45 connectors are teminated in accordance with  
the TIA/EIA 568 A standard.  
Fig u re 2-9 — Ext e n d e r b o a rd a u d io  
co n n e ct o r w irin g  
MEDIUM  
Peaking and Gain  
An RJ-11 plug can be connected to the RJ-45 jack.  
Connect the sleeve to  
ground (Gnd).  
Connecting the sleeve to a  
negative (-) terminal will  
CAUTION  
NORMAL  
Unity Gain  
MAXIMUM  
Peaking and  
Gain  
When cabling the front panel and the underside of the enclosure  
(figure 2-8), ensure that the bottom RJ-45 connections match up  
with the front panel RJ-45 connector locations. For example,  
match the front panel RJ-45 (CAT 6) network, data, or  
damage the audio output circuits.  
communications connection  
with the underside RJ-45  
and so forth.  
5A  
Gain switch — To compensate for cable resistance and  
capacitance, use a Tweeker to slide this switch to select the level  
of video gain that yields the sharpest, smear-free picture.  
11  
connector 6A , match  
with  
6B  
5B  
Normal unity gain (no signal boost)  
Medium mid-level peaking and gain  
5A  
5B Front View  
Maximum maximum amount of peaking and gain. Select  
this setting for use with longer cables.  
Adjust the gain before installing the HSA unit, as the  
gain switch may be inaccessible after installation.  
6A 6B  
Power supply connection — Plug the external power supply  
(included) output wires into this 2-pole direct insertion  
terminal. See “Power connector wiring” to wire the connector.  
12  
Bottom View  
Power LED — Indicates when the Extender board is receiving  
13  
power.  
Fig u re 2-8 — Co n fig u ra t io n o f RJ-45 co n n e ct o rs  
HSA 200/222 Series • Installation  
2-10  
HSA 200/222 Series • Installation  
2-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In st a lla t io n , co n t ’d  
Do not tin the stripped power supply leads. Tinned  
wires are not as secure in the captive screw terminals  
and could pull out.  
Po w e r co n n e ct o r w irin g  
1.  
See figure 2-10. Plug the input connector of the included  
100-240 VAC, 50/ 60Hz, 12 VDC power supply into the AC  
1
power outlet on the underside of the enclosure ( on  
figure 2-5).  
The two power cord wires must be kept separate  
while the power supply is plugged in. Remove  
power before continuing.  
To verify the polarity before connection, plug in the  
power supply with no load and check the output with a  
voltmeter.  
Fro n t Pa n e l Co n n e ct o rs  
MEDIUM  
peaking gain  
NORMAL  
unity gain  
MAXIMUM  
peaking  
gain POWER  
Figure 2-12 shows the front panel of the HSA 200 models.  
Figure 2-13 shows the front panel of the HSA 222.  
&
&
9-18 VDC  
AUDIO  
R
R
L
L
2
3
HSA 200  
4
Power Supply  
Back View  
Fig u re 2-10 — Po w e rin g t h e Ext e n d e r b o a rd  
This outlet is a US-style power outlet on both the US/  
domestic and international HSA 200 models. The power  
output is the same voltage and frequency as the power  
input and is an acceptable power input to the power  
supply included with the HSA.  
HSA 200CE and  
HSA 200SE Models Only  
1
5A  
5B  
Fig u re 2-12 — HSA 200 fro n t p a n e l co n n e ct o rs  
2.  
Insert the external power supply (included) output wires  
into the 2-pole direct insertion captive screw terminal on  
the Extender board (figure 2-11) and secure the wires.  
HSA 222  
125V  
50/60 Hz 5A  
125V  
50/60 Hz 5A  
CAUTION  
When connecting the power supply wires, voltage  
polarity is extremely important. Applying power  
with incorrect voltage polarity could damage the  
power supply and the Extender board in the HSA.  
Black Wire  
White Wire  
12V  
+
-
1
5A  
5B  
1
Fig u re 2-13 — HSA 222 fro n t p a n e l co n n e ct o rs  
Captive Screw  
Terminal  
AC power outlet(s) — Plug a standard power cord into this  
connector to provide AC power (5 amps max.) for a laptop or  
other device. The power output will be the same voltage and  
frequency as power input. The power outlet(s) will be  
appropriate to the model.  
1
Fig u re 2-11 — Po w e r co n n e ct o r w irin g  
HSA 200/222 Series • Installation  
2-12  
HSA 200/222 Series • Installation  
2-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In st a lla t io n , co n t ’d  
The Universal AC outlet is fully compatible with  
Europlug, British, Indian, Danish, and Italian plug  
types. See the universal AC outlet guide on the Extron  
Web site, www.extron.com, for compatibility details on  
all plug types.  
5A  
5B Front View  
Computer video input (HSA 200 models only) — Plug the  
VGA-UXGA output from a computer into this 15-pin HD female  
connector.  
2
6A 6B  
Audio input connector (HSA 200 models only) — Plug a  
3.5 mm stereo plug into this jack for unbalanced audio input.  
Figure 2-14 shows how to wire the male plug.  
3
Tip (+)  
Bottom View  
Ring (  
-)  
Fig u re 2-15 — Co n fig u ra t io n o f RJ-45 co n n e ct o rs  
Sleeve (  
)
Fig u re 2-14 — Au d io in p u t co n n e ct o r p lu g  
Icon Label  
Power/Signal LED (HSA 200SE and HSA 200CE only) — This  
LED lights green when power and an input signal are present.  
The LED lights amber when power is present but no input  
signal is present.  
4
5
RJ-45 connectors — Plug a CAT 5 or CAT 6 twisted pair (TP)  
cable into each of these RJ-45 female connectors for network,  
data, or communication connections.  
Fig u re 2-16 — Ch a n g in g t h e co n n e ct o r ico n  
When cabling the front panel and the underside of the enclosure  
(figure 2-15), ensure that the bottom RJ-45 connections match up  
with the front panel RJ-45 connector locations. For example,  
match the front panel RJ-45 (CAT 6) network, data, or  
communications connection  
with the underside RJ-45  
5A  
connector  
and match  
with  
5B  
.
6B  
6A  
If necessary, on the front panel, have a qualified service person  
replace the connector icon by prying the old icon off of the  
connector plug-in with a Tweeker (figure 2-16) and snapping a  
new icon in place.  
HSA 200/222 Series • Installation  
2-14  
HSA 200/222 Series • Installation  
2-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In st a lla t io n , co n t ’d  
Pre -in st a lla t io n Te st in g a n d Tro u b le sh o o t in g  
(HSA 200CE a n d HSA 200SE Mo d e ls On ly)  
HSA 200/222 Series Surface Access Products  
Before installing an HSA 200 with an Extender line driver into  
furniture, test the system to make sure that the connections and  
settings are correct.  
1.  
Apply power to the line driver. The power/ signal LED on  
the line driver will light to indicate that the line driver is  
receiving power.  
If the LED does not light, check the wiring at both the line  
driver and the power supply, and ensure that the power  
supply is connected to a power source.  
If t h e im a g e d o e s n o t a p p e a r o r t h e re is n o so u n d  
1.  
2.  
Make sure that all the devices are powered on.  
Ensure that the connectors are wired correctly at both ends  
of the cables. Audio cables must be wired for an  
unbalanced stereo input signal and for the appropriate  
(unbalanced or balanced) output signal.  
Chapter Three  
3. If the input is from a laptop computer and no picture  
appears, use a laptop breakout cable for the input  
connection. Check the computers users guide or contact  
Extron to determine if special commands are required to  
output video to the external video port. Also, many  
laptops’ screens shut off after the external video port is  
activated.  
3
4.  
Call the Extron S3 Sales and Technical Support Hotline if  
the image still does not appear or there is no sound.  
Ma in t e n a n ce a n d Mo d ifica t io n s  
If t h e im a g e is n o t d isp la ye d co rre ct ly  
Removing and Replacing the Enclosure  
Replacing the Bezels  
1.  
If the picture is too bright or too dark, or if the edges of the  
image seem to exceed their boundaries, or if thin lines and  
sharp edges look thick and fuzzy, change the gain setting.  
2.  
If the picture appears and is stable, but it has ghosting or  
blooming, verify that the video input is properly  
Replacing the Gas Lift  
terminated. If the problem is not resolved by changing the  
termination, try using a different input cable. Poor quality  
or damaged cable can cause ghosting and blooming.  
Adjusting the Top Panel  
3.  
If the picture still is not displayed correctly, call the Extron  
S3 Sales and Technical Support Hotline.  
HSA 200/222 Series • Installation  
2-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ma in t e n a n ce a n d Mo d ifica t io n s  
The most probable corrective maintenance procedures for your  
The surfaces of the HSA enclosure have screws and other  
protrusions that could damage fine furniture. Do not  
rest the enclosure on unprotected furniture.  
HSA 200 or HSA 222 are leveling the top surface and replacing  
the gas lifts. Most of the maintenance procedures require  
removing the surface mount enclosure from the table.  
5.  
6.  
Perform the desired maintenance procedure.  
If the surface is not level, adjust the top surface. See  
“Adjusting the Top Panel” in this chapter.  
Re m o vin g a n d Re p la cin g t h e En clo su re  
The procedure for replacing the bezel in an HSA 222 only  
requires removing the HSA from the table.  
7.  
8.  
Carefully lower the HSA enclosure into the table opening.  
From the underside of the table, reinstall the screw clamps  
on the enclosure at a height at which the clamp will reach  
the underside of the tabletop.  
The procedure for replacing the gas lift requires removing  
the HSA 200 or HSA 222.  
The procedure for levelling the top surface may require  
9.  
Snugly tighten the Philips head screws on the screw  
clamps to secure the enclosure to the surface.  
removing the HSA.  
Remove and replace the surface mount enclosure for  
maintenance as follows:  
Overtightening the Philips head screws on the screw  
clamps can bend the clamps horizontal flange.  
CAUTION  
Ensure that AC power is disconnected before  
servicing the HSA unit.  
10. Tighten the locking thumbscrews on the screw clamps to  
lock the clamp in position.  
1.  
Disconnect:  
11. Reconnect all of the connectors removed in step 1.  
The IEC power cord  
The RJ-45 connectors from the underside of the surface  
mount enclosure  
Re p la cin g t h e Be ze ls  
The HSA ships with RJ-45/ RJ-11 connector bezel plug-ins in a  
variety of colors and a black, blank bezel.  
(HSA 200 models only) Any device plugged into the AC  
power outlet  
To change to a different color connector bezel or if a connector is  
not needed, replace the connector bezel  
plug-in on the front panel with a bezel of  
a different color or a blank plug-in.  
(HSA 200 models only) The BNC (video) connectors  
(HSA 200 models only) The audio connector  
(HSA 200CE and HSA 200SE only) The power supply  
connector  
If no connector is desired, snap the  
interior RJ-45 connector onto the rear of  
the blank bezel plug-in to hold it  
conveniently out of the way. Retain the  
removed connector bezel plug-in for later use.  
2.  
Loosen the locking  
thumbscrews on the screw  
clamps to unlock the clamp.  
Screw  
Clamp  
Thumbscrew  
3.  
Loosen the screw clamps.  
Replace a bezel as follows:  
4.  
Remove the screw clamps on  
both sides of the enclosure.  
Lift the enclosure from the table.  
1.  
(HSA 222 models only) Remove the surface mount  
enclosure from the table. See “Removing and Replacing  
the Enclosure”, steps 1 through 4.  
The flanged edges of the top of the surface enclosure  
are bevelled to an ultra-fine thickness of less than  
0.04 (4/100)” (approximately 1 mm), and are  
therefore very sharp. These edges are also soft and  
may be easily nicked or bent. Exercise caution  
when handling and mounting the enclosure.  
Mishandling may result in injury to the installer or  
damage the appearance of the enclosure.  
CAUTION  
HSA 200/222 Series • Maintenance and Modifications  
3-2  
HSA 200/222 Series • Maintenance and Modifications 3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d  
2.  
(HSA 222 models only) Remove the four Philips head  
screws from the front access panel (figure 3-1). Retain the  
screws. Lift the panel away from the enclosure.  
3.  
(HSA 222 models only) Disconnect both RJ-45 connectors  
from the underside of the enclosure by simultaneously  
performing steps 3a and 3b:  
a.  
With a Tweeker in one hand, reach through the small  
access hole in the front of the enclosure (figure 3-2)  
and gently pry outward on the front of the RJ-45  
connector detent on the bezel plug-in,  
while you —  
b.  
Reach your other hand through the front panel access  
hole and tilt the connector back.  
This disconnects the connector from the interior of the  
lower enclosure without damaging the bezel plug-in.  
Remove  
front access  
panel.  
Fig u re 3-1 — Re m o vin g t h e fro n t a cce ss p a n e l  
(HSA 222 m o d e ls)  
Fig u re 3-2 — Re le a sin g t h e b e ze l p lu g -in d e t e n t  
(HSA 222 m o d e ls)  
HSA 200/222 Series • Maintenance and Modifications  
3-4  
HSA 200/222 Series • Maintenance and Modifications 3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d  
4.  
Remove the four 1/ 16" hex head screws on the right and  
left sides of the front panel (figure 3-3). Retain the screws.  
Lift the panel away from the enclosure.  
8.  
9.  
Snap the internal RJ-45 connector onto the back of the front  
panel enclosure bezel plug-in.  
(HSA 222 models only) Reach your hand through the  
front panel access hole and snap the lower internal RJ-45  
connectors onto the back of the lower enclosure bezel  
plug-ins.  
Figure 3-3 shows an HSA 200 model. Removing the  
front panel from an HSA 222 is an identical procedure.  
Remove 2 hex head  
screws on each side.  
10. Replace the front panel in the surface mount enclosure and  
secure it in place with the hex head screws removed in  
step 4.  
11. (HSA 222 models only) Replace the front access panel in  
the surface mount enclosure and secure it in place with the  
Philips head screws removed in step 2.  
HSA 200  
A
12. (HSA 222 models only) Reinstall the surface mount  
enclosure. See Removing and Replacing the Enclosure, steps 6  
through 11.  
UDIO  
Lift panel out  
of enclosure.  
Fig u re 3-3 — Re m o vin g t h e fro n t p a n e l  
5.  
With a Tweeker, push down on and  
gently twist on the front of each RJ-45  
connector detent to disconnect the  
connector from the rear of the front panel  
plug-in.  
6.  
7.  
Pinch the top and bottom bezel detents  
together and push the bezel through the  
front panel.  
Snap a replacement bezel in place. If necessary, replace the  
connector icon by prying the old icon off of the connector  
plug-in with a Tweeker (figure 3-4) and snapping a new  
icon in place.  
Icon Label  
Fig u re 3-4 — Ch a n g in g t h e co n n e ct o r ico n  
HSA 200/222 Series • Maintenance and Modifications  
3-6  
HSA 200/222 Series • Maintenance and Modifications 3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d  
Re p la cin g t h e Ga s Lift  
5.  
Turn the surface mount enclosure onto its back side and  
open the top panel.  
The gas lift that raises the HSA surface is rated for 100,000  
opening and closing cycles. Replace the gas lift as follows:  
With the gas lift removed, the top panel must be  
manually lifted.  
Ensure that AC power is disconnected before  
servicing the HSA unit.  
6.  
(HSA 200 models only) Remove the four 1/ 16" hex head  
screws on the right and left sides of the front panel  
(figure 3-6). Retain the screws. Lift the panel away from  
the enclosure.  
When the HSA 200 is upside-down, the latch may  
be ineffective. If the latch releases in this position,  
the enclosure will tip and could damage the flanged  
edges. Keep a free hand on the enclosure to keep it  
from tipping.  
CAUTION  
Figure 3-6 shows an HSA 200 model. Removing the  
front panel from an HSA 222 is an identical procedure.  
1.  
2.  
Remove the surface mount enclosure from the table. See  
Removing and Replacing the Enclosure, steps 1 through 4.  
Place the enclosure upside-down on a horizontal surface.  
To protect the finish, place the enclosure on a soft cloth.  
Remove 2 hex head  
screws on each side.  
Loosen the three Philips head screws that secure the gas  
lift mounting plate in place (figure 3-5).  
HSA 200  
A
UDIO  
Lift panel out  
of enclosure.  
Unscrew mounting plate  
from gas lift.  
Fig u re 3-6 — Fro n t p a n e l re m o va l (HSA 200 m o d e ls)  
Loosen (3)  
screws.  
Fig u re 3-5 — Re m o vin g t h e g a s lift m o u n t in g p la t e  
Figure 3-5 shows an HSA 200 model. Removing the gas  
lift mounting plate from an HSA 222 is an identical  
procedure.  
3.  
4.  
Slide the gas lift mounting plate toward the center of the  
enclosure, releasing the mounting plate (figure 3-5).  
Turn the gas lift mounting plate counterclockwise until the  
plate comes free from the shaft of the gas lift (figure 3-5).  
HSA 200/222 Series • Maintenance and Modifications  
3-8  
HSA 200/222 Series • Maintenance and Modifications 3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d  
7.  
(HSA 222 models only) Remove the four Philips head  
screws from the front access panel (figure 3-7). Retain the  
screws. Lift the panel away from the enclosure.  
8.  
Remove the pivot nut from the upper pivot bolt, then  
remove the bolt, releasing the upper end of the gas lift  
from the top panel. Pull the gas lift from the bottom of the  
enclosure.  
HSA 200 models — Reach through the front panel  
opening (figure 3-8).  
HSA 222 models — Reach through the front access panel  
(figure 3-9 on page 3-12).  
Top Clevis  
Pivot Bolt  
Pivot Nut  
Remove  
front access  
panel.  
Piston End  
Fig u re 3-7 — Fro n t a cce ss p a n e l re m o va l (HSA 222  
m o d e ls)  
Gas Lift  
Fig u re 3-8 — Re p la cin g t h e g a s lift , HSA 200 m o d e l  
HSA 200/222 Series • Maintenance and Modifications  
3-10  
HSA 200/222 Series • Maintenance and Modifications 3-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d  
Ad ju st in g t h e To p Pa n e l  
Level the top panel of the HSA 200 or HSA 222 as follows:  
1.  
If necessary to view the top and the underside of the  
enclosure simultaneously, remove the surface mount  
enclosure from the table. See Removing and Replacing the  
Enclosure, steps 1 through 4.  
Remove  
pivot nut.  
2.  
3.  
Close and latch the top panel.  
Slightly loosen the two latch locking screws (figure 3-10)  
on the underside of the surface mount enclosure. These  
screws lock the latch in place once it is adjusted.  
Adjustment  
Screw  
Remove  
gas lift.  
Fig u re 3-9 — Re p la cin g t h e g a s lift , HSA 222 m o d e l  
9.  
Insert the piston end of the replacement gas lift through  
the hole in the bottom of the enclosure adjacent to the latch  
and secure the lift in the clevis on the top panel with the  
nut and bolt that were removed in step 8.  
Latch Locking  
Screws  
10. (HSA 200 models only) Replace the front panel in the  
surface mount enclosure and secure it in place with the  
hex head screws removed in step 6.  
Fig u re 3-10 — Ad ju st in g t h e t o p p a n e l  
11. (HSA 222 models only) Replace the front access panel in  
the surface mount enclosure and secure it in place with the  
Philips head screws removed in step 7.  
4.  
Gently turn the adjustment screw on the rear of the surface  
mount enclosure to raise or lower the top panel to level it  
with the flange. Turning the screw counterclockwise raises  
the panel and clockwise lowers the panel.  
12. Thread the pivot nut on the gas lift mounting plate onto  
the shaft of the gas lift and tighten it several turns.  
5.  
6.  
Once the top panel is level, tighten the two latch locking  
screws on the underside of the surface mount enclosure.  
13. Firmly push the gas lift mounting plate into position on  
the underside of the surface mount enclosure, engaging  
the three mounting screws that were loosened in step 2.  
Holding the plate in position with one hand, secure it to  
the enclosure with the three screws.  
If the surface mount enclosure was removed, reinstall it. See  
Removing and Replacing the Enclosure, steps 7 through 11.  
14. Reinstall the surface mount enclosure. See “Removing and  
Replacing the Enclosure”, steps 6 through 11.  
HSA 200/222 Series • Maintenance and Modifications  
3-12  
HSA 200/222 Series • Maintenance and Modifications 3-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d  
HSA 200/222 Series Surface Access Products  
Appendix A  
A
Re fe re n ce In fo rm a t io n  
Specifications  
HSA Part Numbers  
Included Parts  
Routing Templates  
Replacement Parts  
Accessories  
Top Plate Dimensions  
HSA 200/222 Series • Maintenance and Modifications  
3-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Re fe re n ce In fo rm a t io n  
Au d io — HSA 200SE, HSA 200CE  
Sp e cifica t io n s  
Gain ................................. Unbalanced output: 0 dB; balanced output: +6 dB  
Vid e o — HSA 200SE, HSA 200CE  
Frequency response ...... 20 Hz to 20 kHz, ±0.5 dB  
Gain ................................. Selectable: unity (0.7 V), (0.75 V) 50%, (0.8 V)  
100%  
THD + Noise .................. 0.025% @ 1 kHz, 0.020% @ 20 kHz at nominal  
level  
Bandwidth ..................... 300 MHz (-3 dB)  
S/ N ................................. >90 dB at rated maximum output (21 dB,  
balanced)  
ID bits are terminated on pins 4 and 11.  
Stereo channel separation >75 dB @ 20 Hz to 20 kHz  
Vid e o in p u t — HSA 200S, HSA 200C  
Au d io in p u t — HSA 200S, HSA 200C  
Number/ signal type .... 1 stereo, unbalanced  
Connectors ..................... (1) 3.5 mm stereo female jack  
Number/ signal type .... 1 VGA–UXGA RGBHV, RGBS, RGsB, RsGsBs  
Connectors ..................... (1) 15-pin HD female  
Vid e o in p u t — HSA 200SE, HSA 200CE  
Number/ signal type .... 1 VGA–UXGA RGBHV, RGBS, RGsB, RsGsBs  
Connectors ..................... (1) 15-pin HD female  
Au d io in p u t — HSA 200SE, HSA 200CE  
Number/ signal type .... 1 stereo, unbalanced  
Connectors ..................... (1) 3.5 mm stereo female jack  
Impedance ...................... >10k ohms unbalanced, DC coupled  
Nominal level ................ -10 dBV (316 mVrms)  
Nominal level ................ 0.7 Vp-p for RGB  
Min./ max. levels ........... Analog: 0.3 V to 1.5 Vp-p with no offset at unity  
gain  
Maximum level ............. +6 dBu, (balanced or unbalanced) at 1%THD+N  
Impedance ...................... 75 ohms  
Au d io o u t p u t — HSA 200S, HSA 200C  
Horizontal frequency ... 15 kHz to 135 kHz  
Vertical frequency ......... 30 Hz to 170 Hz  
Number/ signal type .... 1 pass-through stereo, unbalanced  
Connectors ..................... (1) 3.5 mm, direct insertion captive screw  
connector, 3 pole  
Vid e o o u t p u t — HSA 200S, HSA 200C  
Number/ signal type .... 1 pass-through VGA–UXGA RGBHV, RGBS,  
RGsB, RsGsBs  
Au d io o u t p u t — HSA 200SE, HSA 200CE  
Number/ signal type .... 1 stereo, balanced/ unbalanced  
Connectors ..................... 5 BNC female on pigtails  
Connectors ..................... (1) 3.5 mm direct insertion captive screw  
connector, 5 pole  
Vid e o o u t p u t — HSA 200SE, HSA 200CE  
Number/ signal type .... 1 VGA–UXGA RGBHV, RGBS, RGsB, RsGsBs  
Connectors ..................... 5 BNC female on pigtails  
Nominal level ................ 0.7 Vp-p for RGB  
Impedance ...................... 50 ohms unbalanced, 100 ohms balanced  
Nominal level ................ Unbalanced output: -10 dBV (316 mVrms)  
Balanced output: -2 dBu (632 mVrms)  
Min./ max. levels ........... Analog: 0.3 V to 1.5 Vp-p  
Impedance ...................... 75 ohms  
Max. level (Hi-Z) ........... >+14 dBu, balanced at 1% THD+N  
Max. level (600 ohm) .... >+5.5 dBm, balanced at 1% THD+N  
DC offset ........................ ±5 mV with input at 0 offset  
0 dBu = 0.775 Vrms. 0 dBV = 1 Vrms. 0 dBV 2 dBu.  
Syn c — HSA 200SE, HSA 200CE  
Input type ....................... RGBHV, RGBS, RGsB, RsGsBs  
Output type ................... RGBHV, RGBS, RGsB, RsGsBs  
Input level ...................... 2.0 V to 5.0 Vp-p  
Output level ................... TTL: 5.0 Vp-p, unterminated  
Input impedance ........... 510 ohms  
Output impedance ........ 75 ohms  
Max. propagation delay 18.8 ns  
Max. rise/ fall time ........ 4 ns  
Polarity ........................... Positive or negative (follows input)  
HSA 200/222 Series • Reference Information  
A-2  
HSA 200/222 Series • Reference Information  
A-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Re fe re n ce In fo rm a t io n , co n t ’d  
HSA 200C, HSA 200CE — USA models  
Top plate (outer rim)................... 6.500" diameter circle  
(16.51 cm diameter) circle  
Ge n e ra l  
The Universal AC outlet is fully compatible with Europlug,  
Surface cutout (inside rim)......... 6.000 ±0.0325" diameter circle  
(15.24 ±0.083 cm diameter) circle  
Top plate (inside tilt plate) ......... 4.344" W x 3.000" D  
(11.03 cm W x 7.62 cm D)  
British, Indian, Danish, and Italian plug types. See the  
Universal AC outlet guide on the Extron Web site,  
www.extron.com, for compatibility details on all plug types  
Power (HSA 200SE/ CE) Supplied by an external power supply  
HSA 222C — USA model  
Top plate (outer rim)................... 6.500" diameter circle  
(16.51 cm diameter) circle  
Surface cutout (inside rim)......... 6.000 ±0.0325" diameter circle  
(15.24 ±0.083 cm diameter) circle  
Top plate (inside tilt plate) ......... 4.660" W x 2.875" D  
(11.84 cm W x 7.30 cm D)  
External power supply (HSA 200SE/ CE)  
100 VAC to 240 VAC, 50/ 60 Hz, external,  
autoswitchable; to 12 VDC, 0.42 A, regulated  
Power input requirements (HSA 200SE/ CE)  
12 VDC, 0.2 A  
Temperature/ humidity — HSA 200SE/ CE  
Storage: -40 to +158°F (-40 to +70°C) / 10% to  
90%, noncondensing  
HSA 200S, HSA 200SE, HSA 200C, HSA 200CE — USA models  
Box (under surface) ..................... 4.0" H x 4.6" W (front of unit) x 4.4" D  
(10.2 cm H x 11.7 cm W x 11.2 cm D)  
without clamps  
Operating: +32 to +122°F (0 to +50°C) / 10% to  
90%, noncondensing  
Rack mount .................... No, but furniture mountable  
Enclosure type ............... Metal  
4.0" H x 8.0" W (front of unit) x 4.4" D  
(10.2 cm H x 20.3 cm W x 11.2 cm D)  
with clamps  
Enclosure dimensions  
HSA 222S, HSA 222C — USA models  
Use the appropriate metal Extron routing template or refer to  
the surface cutout dimensions here before cutting a hole in the  
furniture or other surface. Pay special attention to the direction  
the unit will face; the units connector access side is underlined.  
Extron is not responsible for miscut mounting holes.  
CAUTION  
Box (under surface) ..................... 5.6" H x 5.3" W (front of unit) x 3.6" D  
(14.2 cm H x 13.5 cm W x 9.1 cm D)  
without clamps  
5.6" H x 8.6" W (front of unit) x 3.6" D  
(14.2 cm H x 21.8 cm W x 9.1 cm D)  
with clamps  
HSA 200S, HSA 200SE — USA models  
Top plate (outer rim)................... 6.470" W x 5.125" D  
(16.43 cm W x 13.02 cm D)  
Surface cutout (inside rim)......... 5.970 ±0.0325" W x 4.625 ±0.0325" D  
(15.16±0.083cm W x 11.75±0.083cm D)  
HSA 200S/HSA 200SE — international square models  
Top plate (outer rim)................... 8.183" W x 6.375" D  
(20.79 cm W x 16.19 cm D)  
Surface cutout (inside rim)  
7.683 ±0.0325" W x 5.875 ±0.0325" D  
(19.51±0.083cm W x 14.92±0.083cm D)  
Top plate (inside tilt plate) ......... 4.344" W x 3.000" D  
(11.03 cm W x 7.62 cm D)  
Top plate (inside tilt plate)  
5.90" W x 4.10" D  
HSA 222S — USA model  
Top plate (outer rim)................... 6.470" W x 5.125" D  
(16.43 cm W x 13.02 cm D)  
(14.99 cm W x 10.41 cm D)  
HSA 222S — international square models  
Top plate (outer rim)................... 8.183" W x 6.375" D  
(20.78 cm W x 16.19 cm D)  
Surface cutout (inside rim)......... 7.683 ±0.0325" W x 5.875 ±0.0325" D  
(19.51±0.083cm W x 14.92±0.083cm D)  
Surface cutout (inside rim)......... 5.970 ±0.0325" W x 4.625 ±0.0325" D  
(15.16±0.083cm W x 11.75±0.083cm D)  
Top plate (inside tilt plate) ......... 4.660" W x 2.875" D  
(11.84 cm W x 7.30 cm D)  
Top plate (inside tilt plate) ......... 6.183" W x 3.75" D  
(15.70 cm W x 9.53 cm D)  
HSA 200/222 Series • Reference Information  
A-4  
HSA 200/222 Series • Reference Information  
A-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Re fe re n ce In fo rm a t io n , co n t ’d  
HSA 200C/HSA 200CE — international circular models  
Top plate (outer rim)................... 8.5" diameter circle  
(21.6 cm diameter) circle  
HSA Pa rt Nu m b e rs  
HSA 200S  
Pa rt n u m b e r  
HSA 200S US/ domestic (black anodized finish)  
60-510-01  
Surface cutout (inside rim)......... 8.0" diameter (20.3 cm diameter) circle  
HSA 200S International  
60-705-nn  
Top plate (inside tilt plate) ......... 5.9" W x 4.1" D  
(15.1 cm W x 10.4 cm D)  
HSA 200 — international, all models  
HSA 200SE  
Pa rt n u m b e r  
60-511-01  
Box (under surface) ..................... 4.0" H x 6.3" W (front of unit) x 5.0" D  
(10.2 cm H x 15.9 cm W x 12.7 cm D)  
without clamps  
HSA 200SE US (black anodized finish)  
HSA 200SE International  
60-706-nn  
4.0" H x 10.0" W (front of unit) x 5.0" D  
(10.2 cm H x 25.3 cm W x 12.7 cm D)  
with clamps  
HSA 200C  
Pa rt n u m b e r  
HSA 222 — international, all models  
HSA 200C US/ domestic (black anodized finish)  
60-512-01  
Box (under surface) ..................... 4.5" H x 6.6" W (front of unit) x 4.9" D  
(11.4 cm H x 16.8 cm W x 12.4 cm D)  
without clamps  
HSA 200C International  
60-703-nn  
4.5" H x 10.3" W (front of unit) x 4.9" D  
(11.4 cm H x 26.2 cm W x 12.4 cm D)  
with clamps  
HSA 200CE  
Pa rt n u m b e r  
60-513-01  
HSA 200CE US/ domestic (black anodized finish)  
HSA 200CE International  
60-704-nn  
Product weight  
HSA 200S, HSA 200C ................. 4.0 lbs (1.8 kg)  
HSA 222S, HSA 222C ................. 3.5 lbs (1.6 kg)  
HSA 200SE, HSA 200CE .............. 5.0 lbs (2.3 kg)  
HSA 222  
Pa rt n u m b e r  
60-630-01  
HSA 222S US/ domestic (black anodized finish)  
HSA 222C US/ domestic (black anodized finish)  
HSA 222S International  
Shipping weight  
60-631-01  
HSA 200S, HSA 200C, HSA 222S, HSA 222C  
7 lbs (4 kg)  
60-701-nn  
HSA 200SE, HSA 200CE ............. 8 lbs (4 kg)  
For the international versions, the nn in the part number  
identifies the AC power connector and finish (black  
anodized, brushed aluminum, polished aluminum, and  
brushed brass). Specify the desired power connector and  
finish when ordering.  
Vibration ............................................. ISTA 1A in carton  
(International Safe Transit Association)  
Listings, certifications ....................... UL, CUL  
Compliances  
HSA 200SE, HSA 200CE ............. CE, FCC Class A, VCCI, AS/ NZS, ICES  
MTBF ................................................... 30,000 hours  
Warranty ............................................. 3 years parts and labor  
The USA versions of the HSA 200 and HSA 222 are also  
available in brushed aluminum, polished aluminum, and  
brushed brass finishes. Visit the Extron Web site,  
All nominal levels are at ±10%  
Specifications are subject to change without notice.  
HSA 200/222 Series • Reference Information  
A-6  
HSA 200/222 Series • Reference Information  
A-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Re fe re n ce In fo rm a t io n , co n t ’d  
In clu d e d Pa rt s  
Pa rt  
HSA 200S/HSA 200SE/HSA 222S US Models  
6.470" (16.43 cm)  
Pa rt n u m b e r  
HSA 200 and HSA 222 Users Manual  
+
+
5.970 0.0325" (15.16 0.083 cm)  
RJ-45 connector bezel plug-in inserts (assorted colors) 70-201-01  
Power supply, 100-240VAC, 50/ 60Hz, 12VDC  
(HSA 200SE and HSA 200 CE only)  
28-104-01  
SURFACE CUT-OUT  
AREA = 5.970 0.0325"  
+
Tweeker  
+
+
(15.16 0.083 cm) x 4.625 0.0325"  
5.125"  
(13.02 cm)  
+
(11.75 0.083 cm)  
+
+
4.625 0.0325"  
Ro u t in g Te m p la t e s  
(11.75 0.083 cm)  
Te m p la t e  
Pa rt n u m b e r  
70-237-01  
HSA 200/ HSA 222 US routing template  
HSA 200/ HSA 222 International routing template  
70-237-02  
0.5"  
(1.3 cm)  
Re p la ce m e n t Pa rt s  
Cut surface material  
out along this line.  
Tilting Plate  
Cut-Out Radius:  
0.25" (0.6 cm)  
Top Panel  
Pa rt  
Pa rt n u m b e r  
70-281-01  
HSA 200 gas lift  
HSA 222 gas lift  
User Access (Connectors and AAP Openings)  
70-281-02  
TEMPLATE IS NOT FULL SIZE.  
Acce sso rie s  
Pa rt  
Pa rt n u m b e r  
70-231-01  
HSA 200S/HSA 200SE International Models  
8.183" (20.78 cm)  
HSA 200 RJ-45 to RJ-11 Conversion Kit  
HSA 222 RJ-45 to RJ-11 Conversion Kit  
HSA 200/ HSA 222 Flexible Conduit Adapter Kit  
70-231-02  
+
+
7.683 0.0325" (19.51 0.083 cm)  
70-229-01  
To p Pla t e Dim e n sio n s  
SURFACE CUT-OUT  
AREA = 7.683 0.0325"  
+
The cutout dimension illustrations (figures A-1 and A-2) are not  
to scale and are for reference only. If you choose not to use  
Extrons metal routing template (chapter 2, Installation), the  
dimensions on the illustrations will help you properly prepare  
the mounting surface. The surface cutout area is the shaded area  
on the diagrams. The cutout dimensions are provided.  
+
+
(19.51 0.083 cm) x 5.875 0.0325"  
6.375"  
(16.19 cm)  
+
(14.92 0.083 cm)  
+
5.875 0.0325"  
+
(14.92 0.083 cm)  
For full size paper templates, visit the Extron Web site  
Support Hotline.  
0.5"  
(1.3 cm)  
Cut surface material  
out along this line.  
Tilting Plate  
Cut-Out Radius:  
0.25" (0.6 cm)  
Top Panel  
User Access (Connectors and AAP Openings)  
TEMPLATE IS NOT FULL SIZE.  
Fig u re A-1 — HSA 200S/HSA 200SE/ HSA 222S cu t o u t d im e n sio n s  
HSA 200/222 Series • Reference Information  
A-8  
HSA 200/222 Series • Reference Information  
A-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Re fe re n ce In fo rm a t io n , co n t ’d  
HSA 200C/HSA200CE/HSA222C US Models  
HSA 200/222 Series Surface Access Products  
6.5" (16.5 cm)  
+
+
6.000 0.0325" (15.24 0.083 cm)  
SURFACE CUT-OUT  
+
AREA = 6.000 0.0325"  
+
(15.24 0.083 cm) diameter  
Cut surface material  
out along this line.  
Tilting Plate  
Top Panel  
Appendix B  
User Access (Connectors and AAP Openings)  
TEMPLATE IS NOT FULL SIZE.  
B
HSA 200C/HSA 200CE International Models  
8.5" (21.6 cm)  
8.0" (20.3 cm)  
Pa cka g in g fo r Sh ip m e n t  
SURFACE CUT-OUT  
AREA = 8.0"  
(20.3 cm) diameter  
Cut surface material  
out along this line.  
Tilting Plate  
Top Panel  
User Access (Connectors and AAP Openings)  
TEMPLATE IS NOT FULL SIZE.  
Fig u re A-2 — HSA 200C/HSA 200CE/HSA 222C cu t o u t d im e n sio n s  
HSA 200/222 Series • Reference Information  
A-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pa cka g in g fo r Sh ip m e n t  
The HSA 200’s and HSA 222’s ultra-fine machined surfaces and  
2.  
Disconnect all cables and remove the HSA 200 or HSA 222  
from the table or desk. See Removing and Replacing the  
Enclosure, steps 1 through 4, in chapter 3, Maintenance and  
Modifications.  
moving parts make them vulnerable to damage caused by  
mishandling during shipment, if they are improperly packaged.  
If, for any reason, you need to return an HSA to Extron, first  
contact Extron to obtain a return kit. The return kit, which  
reduces the chances of damage during shipment, includes a  
sturdy shipping carton and foam shells custom cut to fit the  
HSA (figure B-1).  
3.  
4.  
Place the enclosure on a flat, horizontal surface. To protect  
the finish, place it on a soft cloth or rubber mat.  
Install the plastic strip (part of the return kit) to protect the  
flanged edges of the top of the enclosure (figure B-2).  
Fig u re B-2 — In st a llin g p ro t e ct ive st rip s  
5.  
Open the top panel and insert the HSA 200 or HSA 222  
into the custom cutout portion of one of the foam shells  
(figure B-3).  
Fig u re B-1 — HSA 200/HSA 222 re t u rn kit  
Package an HSA for shipment as follows:  
1.  
Contact the Extron S3 Sales & Technical Support Hotline to  
obtain a return kit. Extron will send the return kit to the  
location you specify.  
The flanged edges of the top of the surface  
enclosure are sharp when the HSA is removed from  
the table. Exercise caution when handling to  
prevent personal injury.  
The flanged edges of the top of the surface  
enclosure are bevelled to an ultra-fine thickness of  
less than 0.04 (4/100)” (approximately 1 mm).  
These edges are soft and can be easily nicked or  
bent. Exercise caution when handling and  
mounting the enclosure. Mishandling can damage  
the appearance of the enclosure.  
CAUTION  
Fig u re B-3 — In st a llin g t h e HSA in t o t h e fo a m  
sh e ll  
HSA 200/222 Series • Packaging for Shipment  
B-2  
HSA 200/222 Series • Packaging for Shipment  
B-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pa cka g in g fo r Sh ip m e n t , co n t ’d  
6.  
Place the remaining foam shell on the other side of the  
HSA (figure B-4). Firmly push the foam shells together as  
far as they will go to completely suspend the HSA unit.  
Fig u re B-4 — HSA u n it su sp e n d e d in t h e fo a m  
7.  
Place the foam-protected HSA 200 or HSA 222 into the  
shipping carton (figure B-5).  
Fig u re B-5 — HSA in t h e sh ip p in g ca rt o n  
8.  
9.  
Close the shipping carton and seal it with high quality  
shipping tape.  
Ship the HSA to Extron using a reputable shipping  
company.  
B-4  
HSA 200/222 Series • Packaging for Shipment  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Edelbrock Automobile Parts Ford 351 SC 1 V8 User Manual
Electro Voice Speaker ND6x 16 User Manual
Electro Voice Speaker System Sx300 User Manual
Euro Pro Microwave Oven K5345 User Manual
Euro Pro Mixer KM550E User Manual
Extron electronic Car Satellite TV System 330 D User Manual
Extron electronic Telephone XTP SR HDMI User Manual
Fluke Carbon Monoxide Alarm CO 220 User Manual
GE Washer 113D5497P183 User Manual
Go Video DVD VCR Combo VR3845 User Manual