EZN850
User’s Manual
Copyright © EverFocus Electronics Corp,
Release: Dec. 2009 Rev.C
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
About this document
All the safety and operating instructions should be read and followed before the
unit is operated. This manual should be retained for future reference. The
information in this manual was current when published. The manufacturer reserves
the right to revise and improve its products. All specifications are therefore subject
to change without notice.
Safety Notice
-These limits are designed to provide reasonable protection. This equipment
generates, uses and can radiated radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the
following measures: -Reorient or relocate the receiving antenna.
-Increase these separations between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
The changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
To reduce risk of fire or electric shock, do not expose this appliance to rain or
moisture.
Do not attempt to disassemble the appliance. To prevent electric shock, do
not remove screws or covers. There are no user-serviceable parts inside.
Contact qualified service personnel for maintenance. Handle the appliance with
care. Do not strike or shake, as this may damage the appliance.
Do not use strong or abrasive detergents when cleaning the appliance body.
Use a dry cloth to clean the appliance when it is dirty. When the dirt is hard to
remove, use a mild detergent and wipe gently.
Do not operate the appliance beyond its specified temperature, humidity or
power source ratings. Do not use the appliance in an extreme environment where
high temperature or high humidity exists. Use the appliance at temperature within
-40℃ ~ 50℃ / -40 ~ 122 and a humidity below 90%. The input power source for
3
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
this appliance is 24VAC or 100VAC~240VAC.
Use only the recommended power supplies. Power supplies must comply
with the requirement of the latest version of IEC60950-1. Substitutions may
damage the unit or cause a fire or shock hazard.
Electrostatic-sensitive device. Use proper CMOS/MOSFET handing
precautions to avoid electrostatic discharge.
Installation should be performed by qualified service personnel only in
accordance with the National Electrical Code or applicable local codes.
Terms and Trademark
Ethernet, Internet Explorer, Linux, Microsoft, Windows, WWW are registered
trademarks of the respective holders. Other product names appearing in this User's
Guide may be trademarks or registered trademarks of their respective holders.
Java™ and all Java-related logos and trademarks are trademarks or registered
trademarks of Sun Microsystems, Inc. in the United States and other countries.
Support
If the unit ever needs repair service, the customer should contact the nearest
EverFocus Electronics Corp. Service Center for return authorization and shipping
instruction.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
TABLE OF CONTENTS
1. INTRODUCTION....................................................................................................6
2. FEATURES...............................................................................................................6
3. ACCESSING THE CAMERA MENU ...................................................................7
4. SETTING..................................................................................................................9
4.1 SYSTEM INFO ......................................................................................................11
4.1.1 Information .................................................................................................11
4.1.2 Log..............................................................................................................12
4.2 USER CONFIG......................................................................................................13
4.3 NETWORK ...........................................................................................................15
4.3.1 Network.......................................................................................................15
4.3.2 DDNS..........................................................................................................17
4.3.3 Bandwidth...................................................................................................18
4.3.4 SMTP/FTP ..................................................................................................19
4.3.5 Network Alarm (reserved for PowerCon)...................................................21
4.4 VIDEO .................................................................................................................21
4.4.1 Multi Streaming ..........................................................................................22
4.4.2 Camera ........................................................................................................23
4.4.2.1 LENS....................................................................................................24
4.4.2.2 SHUTTER............................................................................................25
4.4.2.3 WHITE BALANCE Control................................................................26
4.4.2.4 BACKLIGHT ......................................................................................27
4.4.2.5 AGC (Auto Gain Control)....................................................................28
4.4.2.6 DNR (Dynamic Noise Reduction).......................................................28
4.4.2.7 SENS-UP .............................................................................................29
4.4.2.8 SPECIAL .............................................................................................30
4.4.2.9 EXIT ....................................................................................................38
4.5 USER..................................................................................................................39
4.6 EVENT...............................................................................................................40
4.6.1 Event ...........................................................................................................41
4.6.2 Motion.........................................................................................................43
4.6.3 Alarm...........................................................................................................44
4.6.4 Time Mask ..................................................................................................46
4.7 SYSTEM............................................................................................................47
4.7.1 Date/Time....................................................................................................47
4.7.2 Daylight Saving ..........................................................................................49
4.7.3 SD Card.......................................................................................................50
4.7.4 Serial Communication ................................................................................53
4.7.5 Maintenance................................................................................................54
5. SPECIFICATIONS................................................................................................56
5
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
1. INTRODUCTION
EZN850 network camera utilizes H.264, MPEG-4 and MJPEG compression for
multiple streaming outputs. Engineered with the advanced new generation 16-bit
DSP, the EZN850 has powerful processing capability to perform 560 TVL of
horizontal resolution. With built-in DNR (Dynamic Noise Reduction), EZN850
provides crystal clear images in low light condition and substantial disk-saving.
Built-in vari-focal auto iris lens for zoom and focus control via web browser.
2. FEATURES
z
Built-in H.264, MPEG-4 and MJPEG multi stream outputs at Full D1 image
size with up to 30 FPS.
z
z
Polestar series perform Sens-up technology x128.
Support 4 independent video streams that can provide different compression
formats and resolutions for simultaneous live monitoring and high
resolution recording.
z
Built-in external adjuster control for 6~50mm auto iris lens (zoom and
focus). Control is available by web browser.
z
z
z
True Day/Night function with IR cut filter.
IR distance up to 50 meters (about 164 ft.) and Vari-Frequency IR control.
Smart Wizard settings for various event management and schedule
recording.
z
Built-in SD memory card slot for local storage and support SD High
Capacity.
z
z
z
z
Motion detection and privacy area functions.
Digital zoom function.
Built-in heater for low temperature environments.
Vandal proof and IP66 weather proof.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
3. ACCESSING THE CAMERA MENU
Step 1. Start an Internet Explorer browser.
Step 2. Enter the IP address or host name of the camera in the Location/Address
field of your browser. (Please refer to EZN850 Installation Guide for how to find
the IP address).
Step 3. Input “Username” and “Password”. Default Username is “user1” and
default password is “11111111”.
Step 4. Click “Login” button.
Step 5. You might be required to download Active X, which is required to view
camera video. Please click "Yes"
Step 6. Congratulation!! You should be able to see the live image now.
1
○ Press
button to display the "Live" page.
Double click on the image to show a full screen display, double click again or press
ESC to return normal display.
2
○ Press
button to enter Setting page. In Setting page, there
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
are 7 sections: [System Info], [User Config], [Network], [Video], [User], [Event] and
[System]. Please refer to “4. Setting” for further information.
3
○ Press
button to close EZN850 network page.
4
○ Video Stream
Select Video Stream from Stream 1, Stream 2, Stream 3 and Stream 4. Please refer to
“4.4.1 Multi Streaming” for further information.
5
○ View Size
You can select View size to either reduce or enlarge the image to the appropriate view
size.
Select the view size for live images from:
704*480/640*480/352*240/320*240/176*120
6
○ Digital Zoom
Press “+” or “-“ button to enlarge / reduce the displayed image. (max. is X10)
7
○ Record
The record button is used to record the current video stream. The location where the
image file is saved can be specified in Setting -> User’s Config. Please refer to “4.2
User Config” for further information.
Note:
Record segment is limited to 5 min. If you need to do long time recording, please set
schedule recording. For more details about schedule recording, please see “4.6
EVENT”.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
8
○ Snapshot
The Snapshot button saves a snapshot of the video image currently being displayed.
The location where the snapshot data is saved can be specified in Setting -> User’s
Config. Please refer to “4.2 User Config” for further information.
9
○ Manual Control – Trigger Event
Press “Trigger Event” button to trigger an event directly from live view page, and
event actions will be effective if they have been set in “Event” menu. (Please refer to
“4.6.1 Event”).
10
○ Manual Control – Reset Alarm
Press “Reset Alarm” button to reset alarm output remotely.
11
○ Status Display
The name of the camera whose settings currently being configured, current date/time
and current frame rate will be displayed.
12
○ Event signals
Alarm
Motion
When an alarm or motion event is triggered, a signal icon will flash to alert user.
The first icon is for alarm event and rest of the 5 icons are for motion event. The
motion event icons which differed by colors correspond to the motion trigger areas
you have set in Motion menu. Please refer to “4.6.2 Motion” for detailed information
about Motion setup.
4. Setting
Click this button to display the setup menu.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
10
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.1 System Info
System information and system log check of the setup menu can be performed on this
page. The “System Info” page has 2 tabs: [Information] tab and the [Log] tab.
4.1.1 Information
System Information: Firmware version, MAC address, Video Type, Model number.
(unchangeable, for reference only)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.1.2 Log
System Log:
Date/Time: displaying date and time of the log.
Log message: all information and event message, including login, user’s IP, reboot,
firmware upgrade, load factory default, configuration reset and event detected.
System will keep the latest 256 records.
Press
button to export system log into “.txt” file and select the
location where the exported log file will be saved to.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.2 User Config
Live view configuration is to be set by user. Each login user can make his/her own
settings for the following items:
Text Setting
Check the box for text of Machine name, Date/Time or Frame Rate to be
displayed on the screen.
Text Color
Foreground Color: Select the foreground color of text to be displayed by moving
the slide bar between Red, Green and Blue until your desire color is obtained.
Position: Select the position where the text will be displaying from Upper Left /
Lower Right / Lower Left.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
Date/Time Format Used in Text
Select Date/Time Format from the following options:
13
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Time Format: 24 Hours or 12 Hours.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
Recording/Snapshot Export Setting
Enable Event Recording to PC: Allow event video recorded to users' PC if any
events have been set to record to PC.
Export folder: Select Export folder by clicking on
folder to be exported.
button, then direct to the
File size: Able to limit the size of the single recording file in minutes. When the
single recording file size exceeds the time you set, system will create a new file to
continue recording.
Overwrite: Select “ON” for overwriting recording/snapshot file when the disk
storage capacity is full.
If the remaining hard disk capacity is less than ____ MB (enter the value you wish
to set between 50~2000), system will stop recording or start overwriting.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
Language Setting
Language: Select the language to be displayed in web page. Default language is
English. To add a new language which is not listed in the original configuration,
press the Browse button to locate the new language file (.evb) and then click the
Load button.
Note:
1. Maximum five languages can be in the language list.
2. Upload a new language file will reboot system automatically. Please
reconnect IP camera after reboot.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Press Apply to apply the setting changes or Reset to reset without saving the
change.
4.3 Network
The network settings and the settings relating to Network, DDNS, Bandwidth,
SMTP/FTP and Network Alarm can be configured on this page.
The "Network setup" page has 5 tabs: the [Network] tab, the [DDNS] tab, the
[SMTP/FTP] tab and the [Network alarm] tab.
4.3.1 Network
The following information is required to configure the network settings. Contact
the network administrator or your Internet service provider.
• IP Type
• IP address
• Subnet mask
• Gateway (when using the gateway server/router)
• Primary DNS, Secondary DNS (when using DNS)
• HTTP Port
15
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
IP Setting
IP Type
DHCP: Configure the DHCP server not to assign the same IP addresses used for
the other network cameras and PCs whose IP address is unique.
Refer to the network administrator for the settings of the server.
Default: DHCP.
Static IP: User can manually set the static IP for network connection.
PPPoE: This is a DSL connection application, ISP will ask user to input user name
and password.
Note: If PPPoE is used as IP type, IP Utility software will not be able to detect
the device.
IP address
When not using DHCP, enter the IP address of the camera. Do not enter the IP
address already used for PC or other network cameras.
Subnet Mask
This field is to set the netmask for your network so as the IP camera will be
recognized within the network. Example: 255.255.255.000. When DHCP is
selected, the DHCP server will assign this value automatically.
Gateway
This field is to set the gateway for your network so the IP camera will be
recognized within the network. When DHCP is selected, the DHCP server will
assign this value automatically.
Primary DNS
An IP address of DNS server that is provided by ISP.
Secondary DNS
If your ISP provides you an IP address secondary DNS, please set it here.
Username
Enter User name of the account (used only for PPPoE).
16
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Password
Enter Password of the account (used only for PPPoE).
Press Apply to apply the setting changes or Reset to reset without saving the
change.
Port Setting
HTTP Port
Port number for HTTP/WEB communication.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
4.3.2 DDNS
DDNS setting
When accessing the camera via the Internet from the network environment of
which the global IP address is obtained using DHCP, the DDNS function is
necessary.
To use the DDNS function, it is necessary to connect to the dedicated DDNS
17
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
server. We offer 4 DDNS server providers as follow:
Enable: Check the box to enable DDNS setting.
Service ISP: If you choose EverFocus DDNS server, you can obtain a free account
Enter an IP Cam Account Name:
.everfocusddns.com
Press button to register or update DDNS account.
If you wish to get a domain name from other DDNS provider, it is necessary to
configure Record ID, FQDN, Username and password and register in DDNS server.
Refer to the web site for further information about the DDNS.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
4.3.3 Bandwidth
18
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Bandwidth Setting
Max. Bandwidth: Specify, Unlimited / 64 K/ 128 K/ 256 K / 512 K / 1M / 2M / 4M
/ 8M bps. the maximum bandwidth that the camera is allowed to use on the
network. This is a useful function when connecting the camera to busy or heavily
loaded networks. The default setting is Unlimited.
Max. Client Limit: enter a value here to restrict the number of clients accessing the
camera. This is useful if you need to save on bandwidth. Up to 32 clients is
allowed to see live video simultaneously. Subsequent viewers will see a blank
image.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
4.3.4 SMTP/FTP
Set SMTP
The settings relating to the mail server used to send the e-mail notification from the
camera to predefined addresses via SMTP can be configured.
SMTP Server: Enter the IP address or the host name of the SMTP server used to
19
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
send e-mails.
SMTP Port: Enter the port number for SMTP. Default is 25.
Authentication: Check the box, if the SMTP server requires Authentication (user/
password).
User name: Input the login user ID if the SMTP server requires Authentication.
Password: Input the password if the SMTP server requires Authentication.
Receiver Address: Input the e-mail address for receiving e-mail message when the
EVENT is enabled and triggered. Please use “;” to separate address.
Sender Address: Input sender’s e-mail address, so that receiver can recognize the
sender when an event message is sent out.
Send Test Mail: Press
address.
button to send a testing mail to the assigned
Set FTP
The settings relating to the FTP server used to transmit the alarm images can be
configured.
FTP Server: Enter the IP address or the host name of the FTP server.
FTP Port: Enter the port number for FTP server. Default is 21.
Recording Path: Assign the recording path.
User Name: Set FTP User’s name.
Password: Set FTP password.
PASV mode: Check to enable Passive mode, enable Passive mode in normal
situation. When it failed to establish the connection, uncheck "PASV" mode.
Test FTP Server: Press
FTP server.
button to send a testing file to the assigned
Press Apply to apply the setting changes or Reset to reset without saving the
change.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.3.5 Network Alarm (reserved for PowerCon)
Set Network Alarm
This function is reserved for PowerCon software, for the detail setting please refer
to PowerCon network alarm protocol.
4.4 Video
The settings relating video such as streaming, camera OSD can be configured on
this page.
The "Video" page has 2 tabs: the [Multi-streaming] tab and the [Camera] tab.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.4.1 Multi Streaming
Stream Setting
The system can output 4 video streams simultaneously. For each of them, user can
set compression format, resolution, quality and frame rate individually. Stream 1 is
always enabled for live view.
Check “Enable” box to enable other streams.
Format: Select encode format from H.264, MPEG4 and MJPEG..
Resolution: NTSC: 4CIF (704*480) / VGA (640*480) / CIF (352*240) / QVGA
(320*240) / QCIF (176*120)
PAL: 4CIF (704*576) / VGA (640*480) / CIF (352*288) / QVGA 320*240) /
QCIF (176*144).
Quality: there are 8 types of quality, please choose from Highest / Higher / High /
Middle / Normal / Low / Lower / Lowest.
Frame Rate: select from NTSC: 1 / 3 / 5 / 15 / 30 fps, PAL: 1/ 2.5/5/12.5/25 fps.
Note:
1. Total frame rate cannot exceed 60 fps.
2. System performance may be influenced if user enables 4 video streams simultaneously.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Press Apply to apply the setting changes or Reset to reset without saving the
change.
Video Recording Setting
User can set video recording by selecting one of the enabled video streams. This
will allow user to view live images as well as to record video of the other video
streaming.
Video Stream: Select video recording stream from any enabled stream.
Video File format: Recording file will be saved as AVI or ARV, select which file
format to be used.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
4.4.2 Camera
Lens Control:
23
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
To adjust the viewing range, press “++” , “+” sign of Zoom to zoom out, and “-“ ,
“--“ sign of Zoom to zoom in.
Press “++”, “+“, “-“ or “--“ sign to set Focus manually.
OSD setting:
Use the following buttons on the operation panel to operate the "Camera OSD
setting" through a PC. (Please refer to 4.4.2.1 for detail guide of Camera OSD
Setting)
[SET] button:
Click this button to move to the submenu.
[Left] button/ [Right] button:
Click these buttons to select the parameters.
[Down] button/ [Up] button:
Click these buttons to move the cursor.
ICR Switch Setting:
AUTO: ICR switches automatically according to the illumination.
B/W: Select to keep B/W image.
COLOR: Select to keep color image.
4.4.2.1 LENS
1. When the SETUP menu is displayed on the screen, please direct the arrow to
point to “LENS” by clicking the UP (c) or DOWN (d) key. Click Left (e) or Right
(f) key to adjust IRIS level (the higher is brighter). In most cases, you don’t need to
adjust this, since Lens is Auto Iris supported.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
SETUP
LENS
> LENS
SHUTTER
DC <┘
___
> LEVEL
|+++++++++| 20
WHITE BAL.
BACKLIGHT
AGC
ATW
OFF
MIDDLE
LOW
DNR
SENS-UP
SPECIAL <┘
EXIT
AUTO <┘
Note:
Since DC lens is a built-in lens for EZN850 camera, it does not support Manual lens,
please do not select lens as Manual mode, it disables sens-up and may cause
malfunction of lens.
2. Please click SET key for saving setting and return to the previous menu.
4.4.2.2 SHUTTER
1. When the SETUP menu is displayed on the screen, please direct the arrow to
point to “SHUTTER” by clicking the DOWN (d) key.
2. Select the shutter mode by clicking the LEFT (e) or RIGHT (f) key.
Three modes are available. FLK, ESC and Manual.
Note:
Since DC lens is a built-in lens for EZN850 camera, shutter does not support ESC
and Manual functions. ESC and Manual are reserved functions, please do not select
these two options in normal situation.
Ö FLK: Please select “FLK” mode when flickering occurs on the screen, which
is caused by an irregular balance between illumination and frequency. NTSC
model: 1/100, PAL model: 1/120.
SETUP
LENS
MANUAL
FLK
ATW
OFF
MIDDLE
LOW
> SHUTTER
WHITE BAL.
BACKLIGHT
AGC
DNR
SENS-UP
SPECIAL <┘
EXIT
___
25
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Ö ESC: (Reserved).
SETUP
BRIGHTNESS
BRIGHTNESS |+++++++++| 25
LENS
MANUAL
ESC <┘
ATW
OFF
MIDDLE
LOW
> SHUTTER
WHITE BAL.
BACKLIGHT
AGC
DNR
SENS-UP
SPECIAL <┘
EXIT
AUTO <┘
Ö Manual: (Reserved).
SETUP
SHUTTER
> MANUAL 1/50
LENS
MANUAL
MANUAL <┘
ATW
OFF
MIDDLE
LOW
> SHUTTER
WHITE BAL.
BACKLIGHT
AGC
DNR
SENS-UP
SPECIAL <┘
EXIT
___
3. Click the SET key when you finish all the settings.
Note:
With DC lens, the shutter speed is fixed as 1/60 for NTSC and 1/50 for PAL.
4.4.2.3 WHITE BALANCE Control
The screen color can be adjusted by using the WHITE BALANCE function.
1. Please direct the arrow to point to “WHITE BAL” on the SETUP menu by
clicking UP (c) or DOWN (d) key.
2. Please select the mode you would like to operate by clicking LEFT (e) or RIGHT
(f) key.
Please select one of the 3 modes below:
Ö ATW (Auto Tracking White Balance): This mode can be used within the color
temperature range from 2,500°K to 8,300°K (eg, fluorescent light, outdoor,
sodium vapor lamp or inside tunnels).
Ö AWC (Auto White Balance Control): Click the SET key while the camera is
directed at a piece of white paper to get the optimum state under the present
illumination. If the environment and the light source are changed, you need to
26
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
adjust the white balance again.
Ö MANUAL: The manual adjustment mode enables a more precise adjustment.
Please select ATW or AWC first. Then change to manual adjustment mode and
click SET key. Set the suitable color temperature, and increase or decrease the
red and blue color values at the same time while checking the color changes of
the object.
SETUP
LENS
DC <┘
___
MANUAL <┘
OFF
MIDDLE
LOW
WHITE BAL.
SHUTTER
> WHITE BAL.
BACKLIGHT
AGC
RED
BLUE
|+++++++++| 32
|+++++++++| 39
DNR
SENS-UP
SPECIAL <┘
EXIT
AUTO <┘
Note:
Under the following conditions, the WHITE BALANCE function may not operate well. In
such cases, please select the AWC mode.
1. When the object’s surroundings have a high color temperature.
2. When the object’s surroundings are dark.
3. If the camera faces a fluorescent light directly or is installed in a place where the
illumination changes constantly, the WHITE BALANCE function may become unstable.
4.4.2.4 BACKLIGHT
Even there is a massive backlight behind the object, bright images of the background
and the object can still be obtained by using the BACKLIGHT function.
1. Please direct the arrow to point to “BACKLIGHT” on the SETUP menu by
clicking UP (c) or DOWN (d) key.
2. Select the mode you would like to operate by clicking LEFT (e) or RIGHT (f)
key.
SETUP
LENS
DC <┘
___
ATW
OFF
MIDDLE
LOW
SHUTTER
WHITE BAL.
> BACKLIGHT
AGC
DNR
SENS-UP
SPECIAL <┘
EXIT
AUTO <┘
27
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Ö HIGH: The gain increases from 0dB up to 42dB.
Ö MIDDLE: The gain increases from 0dB up to 30dB.
Ö LOW: The gain increases from 0dB up to 18dB.
Ö OFF: BACKLIGHT function does not operate.
4.4.2.5 AGC (Auto Gain Control)
1. Please direct the arrow to point to “AGC” on the SETUP menu by clicking UP (c)
or DOWN (d) key.
2. Select the mode you would like to operate by clicking LEFT (e) or RIGHT (f)
key. The more the level of gain increases, the brighter the screen and the level of
noise increases as well.
Ö HIGH: The gain increases from 6dB up to 42dB.
Ö MIDDLE: The gain increases from 6dB up to 30dB.
Ö LOW: The gain increases from 6dB up to 18dB.
Ö OFF: The gain is fixed at 6dB.
SETUP
LENS
DC <┘
___
ATW
SHUTTER
WHITE BAL.
BACKLIGHT
OFF
> AGC
DNR
MIDDLE
LOW
SENS-UP
SPECIAL <┘
EXIT
AUTO <┘
4.4.2.6 DNR (Dynamic Noise Reduction)
Dynamic Noise Reduction in video images has the following effects.
1. Images are brighter and sharper.
2. When the level of noise is reduced, the performance of a camera can apparently be
improved.
3. When it is recorded digitally, reduced noise can reduce image file size.
As the level of gain changes, the background noise in the low light level automatically
decreases.
1. Please direct the arrow to point to “DNR” on the SETUP menu by clicking UP (c)
or DOWN (d) key.
2. Select the mode you would like to operate by clicking LEFT (e) or RIGHT (f)
key.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
SETUP
LENS
DC <┘
___
ATW
OFF
MIDDLE
LOW
SHUTTER
WHITE BAL.
BACKLIGHT
AGC
> DNR
SENS-UP
SPECIAL <┘
EXIT
AUTO <┘
Ö OFF: No reduction in noise level.
Ö LOW: Little reduction in noise level with nearly no ghost image. Default
value is LOW.
Ö MIDDLE: Just enough reduction in noise levels without causing much ghost
imaging.
Ö HIGH: Huge reduction in noise level, which may cause much ghost imaging.
Note:
When AGC is turned off, DNR will be disabled.
4.4.2.7 SENS-UP
SENS UP is used to keep a brilliant, vivid screen image by automatically detecting
changes in the level of light under low light level conditions. The value is from x2
~x128.
1. Please direct the arrow to point to “SENS UP” on the SETUP menu by clicking
UP (c) or DOWN (d) key.
2. Select the mode you would like to operate by clicking LEFT (e) or RIGHT (f)
key.
Ö AUTO: Low light level auto mode. Default value is AUTO (Up to X 10).
SETUP
LIMIT
LENS
DC <┘
___
ATW
OFF
MIDDLE
LOW
SHUTTER
WHITE BAL.
BACKLIGHT
AGC
> AUTO
X 10
DNR
> SENS-UP
SPECIAL <┘
EXIT
AUTO <┘
Ö OFF: The function is disabled.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
3. Click the SET key when you finish all the settings.
Note:
1. The maximum storage magnification in low light level movement situations can be
adjusted by clicking the SET key in “AUTO” mode.
2. The screen becomes brighter when the magnification increases; yet the after image
increases as well.
3. Please note that spots and noise may appear if storage magnification increases when
SENS-UP is operating. This is a normal phenomenon.
4.4.2.8 SPECIAL
1. Please direct the arrow to point to “SPECIAL” on the SETUP menu by clicking
UP (c) or DOWN (d) key.
SETUP
LENS
DC <┘
___
ATW
OFF
MIDDLE
LOW
SHUTTER
WHITE BAL.
BACKLIGHT
AGC
DNR
SENS-UP
> SPECIAL <┘
EXIT
AUTO <┘
2. Select the mode you would like to operate by clicking LEFT (e) or RIGHT (f)
key.
SPECIAL
> CAMERA ID
COLOR ADJ. <┘
SYNC.
OFF
INT
MOTIION DET
PRIVACY
MIRROR
SHARPNESS
RESET
OFF
OFF
OFF
ON <┘
RETURN <┘
4.4.2.8.1 CAMERA ID
Input the camera ID, and it will be appeared on the monitor.
1) Please direct the arrow to point to “CAMERA” by clicking UP (c) or DOWN (d)
key.
2) Select “ON” by clicking LEFT (e) or RIGHT (f) key.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
3) Click the SET key.
4) Maximum 15 letters can be used for the ID.
¾ Clicking UP (c), DOWN (d), LEFT (e) or RIGHT (f) key to select the
letters.
¾ Click the SET key to lock in the letters.
5) Once a name has been selected, please choose a position where you would like to
display the name.
¾ Move the cursor onto “POS” and click the SET key.
¾ The name will appear at the top left hand corner.
¾ Please use the 4 directional buttons to find the desired position to display the
name.
6) If you would like to cancel the ID inputted, please move the cursor to “CLR”, and
all the letters inputted will be deleted.
7) Select “END” and click the SET key to complete ID input.
SPECIAL
> CAMERA ID
COLOR ADJ. <┘
SYNC.
ON
INT
MOTIION DET
PRIVACY
MIRROR
SHARPNESS
RESET
OFF
OFF
OFF
ON <┘
RETURN <┘
C
B
A M E R A
I
I
D
J
A
C D
E
F
G H
K
L
Y
l
M
Z
m
z
N O P Q R S
T
g
t
U
h
u
4
V W X
a
n
b
o
·
c
d
q
0
e
r
f
i
j
k
x
7
p
s
2
v
5
w
6
y
8
─
1
3
9
C
-
L
-
R
-
P O S
E N D
←
→
-
-
-
-
-
-
-
-
-
-
-
-
31
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.4.2.8.2 COLOR ADJ
Adjust the Color Gain from 0 ~ 15
SPECIAL
CAMERA ID
> COLOR ADJ. <┘
SYNC.
MOTIION DET
PRIVACY
MIRROR
SHARPNESS
RESET
OFF
COLOR GAIN.
|++++++++| 8
INT
> LEVEL
OFF
OFF
OFF
ON <┘
RETURN <┘
4.4.2.8.3 SYNC
There are two SYNCHRONIZATION modes: INTERNAL and EXTERNAL
LINE-LOCK. In LINE-LOCK mode, without a synchronous generator, it
synchronizes the video signal between cameras. The Line-Lock synchronization is
only used in the places of 60Hz (NTSC models) or 50Hz (PAL models).
-INT: Internal synchronization
-LL: External line-lock synchronization
=> If you choose “LL”, you can adjust the phase your wish to set. Then click the
SET key. You can adjust the phase you wish to set from 0 to 359.
SPECIAL
CAMERA ID
COLOR ADJ. <┘
> SYNC.
MOTIION DET
PRIVACY
OFF
SYNC
LL <┘
OFF
OFF
> PHASE
|++++++++| 0
MIRROR
OFF
SHARPNESS
RESET
ON <┘
RETURN <┘
4.4.2.8.4 MOTION DETECTION
EZN850 enables you to observe movements of objects in 4 different places on the
screen, the message “MOTION DETECTED” appears on the screen when movement
is detected; therefore this helps to improve supervision efficiency. The camera detects
an object’s movement by sensing discrepancy of outline.
1) Please direct the arrow to point to “MOTION DET” by clicking UP (c) or
DOWN (d) key.
2) Select “ON” by clicking LEFT (e) or RIGHT (f) key.
3) Click the SET key.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
SPECIAL
CAMERA ID
MOTION DETECTION
OFF
COLOR ADJ. <┘
> AEREA SEL
AREA STATE
TOP
DOWN
LEFT
AREA1
ON
|+++++++++| 10
|+++++++++| 25
|+++++++++| 20
|+++++++++| 40
SYNC.
INT
ON <┘
OFF
OFF
ON <┘
> MOTIION DET
PRIVACY
MIRROR
SHARPNESS
RESET
RIGHT
RETURN <┘
Press SET to return
z Please select the area you would like to detect from the 4 areas in AREA SEL
mode.
z Please select ON mode for the chosen area.
z Please click UP (c) or DOWN (d) key to move between TOP, DOWN, LEFT
and RIGHT for adjusting the size of the area.
z Please click LEFT (e) or RIGHT (f) key to adjust the value for size of the
area.
AREA1
AREA3
AREA2
AREA4
z Additionally, it is possible to change the position of the area. Please refer to
the following example for detailed steps on moving AREA1 to center.
1. The original position of AREA1 was TOP: 10, DOWN: 25, LEFT: 20 and RIGHT:
40.
AREA1
33
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
2. Increase DOWN scale value by 20. AREA1 position after change is: TOP: 10,
DOWN: 45, LEFT: 20 and RIGHT: 40.
AREA1
3. Increase TOP scale value by 20. AREA1 position after change is: TOP: 30,
DOWN: 45, LEFT: 20 and RIGHT: 40.
AREA1
4. Increase RIGHT scale value by 20. AREA1 position after change is: TOP: 30,
DOWN: 45, LEFT: 20 and RIGHT: 60.
AREA1
5. Increase LEFT scale value by 20. AREA1 position after change is: TOP: 30,
DOWN: 45, LEFT: 40 and RIGHT: 60.
AREA1
In order to save the changes and complete the setting, click the SET key. This
allows you to return to the previous menu.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.4.2.8.5 PRIVACY
This mode covers the areas you do not want to see on the screen.
1) Please direct the arrow to point to “PRIVACY” by clicking UP (c) or
DOWN (d) key.
2) Select “ON” by clicking LEFT (e) or RIGHT (f) key.
3) Click the SET key.
SPECIAL
PRIVACY
CAMERA ID
COLOR ADJ. <┘
SYNC.
MOTIION DET
> PRIVACY
MIRROR
SHARPNESS
RESET
RETURN <┘
OFF
> AEREA SEL
AREA STATE.
AREA TONE
TOP
AREA1
OFF
INT
OFF
ON <┘
OFF
|+++++++++| 80
|++++++++| 10
|+++++++++| 25
|+++++++++| 20
|+++++++++| 40
DOWN
LEFT
RIGHT
ON <┘
z
Please select the area you would like to cover from the 4 areas in AREA
SEL mode.
z
z
Please select ON mode for the chosen area.
Please select AREA TONE for cover area color. The smaller the number,
the darker the color.
z
z
Please click UP (c) or DOWN (d) key to move between TOP, DOWN,
LEFT and RIGHT for adjusting the size of the area to be covered.
Please click LEFT (e) or RIGHT (f) key to adjust the value for size of the
area to be covered.
AREA1
AREA3
AREA2
AREA4
z
Additionally, it is possible to change the position of the area to be covered.
Please refer to the following example for detailed steps on moving AREA1
to center.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
1. The original position of AREA1 was TOP: 10, DOWN: 25, LEFT: 20 and RIGHT:
40.
AREA1
2. Increase DOWN scale value by 20. AREA1 position after change is: TOP: 10,
DOWN: 45, LEFT: 20 and RIGHT: 40.
AREA1
3. Increase TOP scale value by 20. AREA1 position after change is: TOP: 30,
DOWN: 45, LEFT: 20 and RIGHT: 40.
AREA1
4. Increase RIGHT scale value by 20. AREA1 position after change is: TOP: 30,
DOWN: 45, LEFT: 20 and RIGHT: 60.
AREA1
36
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
5. Increase LEFT scale value by 20. AREA1 position after change is: TOP: 30,
DOWN: 45, LEFT: 40 and RIGHT: 60.
AREA1
z
In order to save the changes and complete the setting, click the SET key. This
allows you to return to the previous menu.
4.4.2.8.6 MIRROR
-ON: Sets a horizontal image 180 angle inversion.
-OFF: Disable the inversion.
SPECIAL
CAMERA ID
COLOR ADJ. <┘
SYNC.
OFF
INT
MOTIION DET
PRIVACY
> MIRROR
SHARPNESS
RESET
OFF
OFF
OFF
ON <┘
RETURN <┘
4.4.2.8.7 SHARPNESS
The contour of the video image becomes cleaner and more distinguishing as the level
of SHARPNESS increases. If the level goes up extremely, it may affect the video
image and cause noise.
-ON: Enable the SHARPNESS mode.
-OFF: Disable the SHARPNESS mode.
z
z
Please click the SET key.
The available range of level is 0~31.
SPECIAL
CAMERA ID
COLOR ADJ. <┘
SYNC.
MOTIION DET
PRIVACY
MIRROR
> SHARPNESS
RESET
OFF
SHARPNESS
|+++++++++| 8
INT
> LEVEL
OFF
OFF
OFF
ON <┘
RETURN <┘
37
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.4.2.8.8 RESET
Click SET key on “RESET” for 3 seconds until it restarts. It will go to factory
default value.
SPECIAL
CAMERA ID
COLOR ADJ. <┘
SYNC.
OFF
INT
MOTIION DET
PRIVACY
MIRROR
SHARPNESS
> RESET
OFF
OFF
OFF
ON <┘
RETURN <┘
4.4.2.8.9 RETURN
Click SET key on “RETURN”. It saves all settings in SPECIAL menu and returns to
the Setup menu.
SPECIAL
CAMERA ID
COLOR ADJ. <┘
SYNC.
OFF
INT
MOTIION DET
PRIVACY
MIRROR
SHARPNESS
RESET
OFF
OFF
OFF
ON <┘
> RETURN <┘
4.4.2.9 EXIT
Click SET key on “EXIT” after you finish all the settings. It will return to live image.
Note: If you quit the Menu without clicking EXIT, all the settings you previously
did will NOT be saved.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.5 USER
User Information
Maximum 10 users can be set for using the IP camera. The user information
displays the authorized users and access levels:
• Supervisor/Administrator –a supervisor/administrator has unrestricted access to
the Setting menu and can determine the registration of all other users. However,
administrator is not allowed to change supervisor’s account and password.
• User- a user can view the Live View page, system info, network, video and
adjust user config settings. The user does not have access to the “user”, “event”
and “system pages”.
• Guest- the lowest level of access, which only allows the user access to the Live
View page.
Note: Please select Active in Status section to activate user account.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.6 EVENT
An event in the camera is when an Event Type is activated and causes certain actions
to be performed. The event type is the set of conditions that specifies how and when
which actions will be performed.
This table describes how to setup action types and event type.
Event Type
Action Type
Manual
Trigger
Motion
Schedule
Alarm Input
Detection
Recording Pre/Post-Alarm
Trigger Alarm
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Send Mail notification
Upload to FTP**
Record to SD Card
Record to PC*
x
x
x
x
x
Network Alarm
Re-trigger
Note: 1. * Record to PC only works when PC and IP camera are connected.
2. **Either Upload to FTP or Record to Network Storage can be selected to
record event video to remote site.
3. Up to 10 event types can be configured in the camera, and up to 3 of these
can be configured to upload images.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.6.1 Event
The settings relating to event occurrences such as settings for the event occurrence,
motion, alarm and time mask can be configured on this page.
The "Event" page has 4 tabs: the [Event] tab, the [Motion] tab, the [Alarm] tab and
the [Time Mask] tab.
Press
button to add an event condition.
To modify the event list, click on the event and it will be highlighted. Press
button to modify the setting.
To remove an event from event list, click on the event and it will be highlighted.
Press
button to remove the event.
Check Enable checkbox to activate event actions when the event occurs in the
specified time zone.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
To change the priority of events, click on the event and it will be highlighted. Press
or
button to move between events. The event that has
highest priority will be activated first.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
This example describes how to set the camera to upload images to FTP when
someone press Manual trigger button:
1. Click
button in Event page.
2. Enter an event name for the event, e.g. Event 1
3. Select “Manual Trigger” as event type.
4. Select “Upload to FTP” as action type.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
5. Check “Enable Pre-alarm Buffer” and “Enable Post-alarm Buffer”. For pre-and
post alarm buffer setting, please refer to “4.6.3 Alarm”.
6. Check “Enable This Event”.
7. Select “Always” for time mask. For detail about Time Mask, please refer to
“4.6.4 Time Mask”.
8. Click
to save this event in event list.
4.6.2 Motion
Motion Detection
User can define the motion area to be detected by left clicking the mouse to draw
lines. Every click is an end point of the line. When the detection area is formed,
double click the mouse to have all the lines connected. To remove the selection,
simply right click the mouse, the selected polygon will be deleted.
Steps for setting motion detection areas:
1. Motion Detection video is not a moving video. For getting the most update
picture, press
to update the current image.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
2. Press
to have the entire screen selected for motion detection. Press
to clear all selections. Press
and click on the polygon, to
erase that polygon.
3. You can select 5 individual motion area, which can be distinguished by 5
different colors.
4. Select color to choose the area you want to enable.
5. Check Enable checkbox to enable event action.
6. You can set the Sensitivity level for motion triggered by selecting from 1 (low),
2, 3, 4, 5, 6, 7, 8, 9 to 10 (high).
7. For each of them, you can set the event action to be activated. Event action can
be set in “Event” section.
4.6.3 Alarm
44
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Alarm Output Setting
Contact Type: Normal Close, Normal Open
Duration Time: Select duration time of alarm output from 5 sec, 10 sec, 20 sec, 30
sec, 60 sec, 2 min, 3 min and 5 min.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
Pre/Post Alarm Setting
This function is used to check what happened immediately before and after a
trigger, e.g. 5 seconds before or after a motion has been detected.
Pre-Alarm Buffer: Image saved internally in the server from the time immediately
preceding the trigger. Input the desired length of pre-trigger buffer time. It can be
set up to 120 seconds.
Post-Alarm Buffer: Image saved internally in the server from the time immediately
after the trigger. Input the desired length of post-trigger buffer time. It can be set
up to 120 seconds.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
Re-trigger Filter Setting
Re-trigger Filter: Set a re-trigger filter time, if another event is triggered during
this time, this triggered event will be ignored.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.6.4 Time Mask
Time Mask Setting
Time mask setting allows you to schedule event actions.
Select Always for event action to be taken continuously.
Press
button to add new time period.
Mask name: Input a mask name for the new time period.
Check the check box for the day to be scheduled: Sun, Mon, Tue, Wed, Thu, Fri &
Sat.
Set the Start time and End time for time mask by clicking Up arrow or Down
arrow. Or simply press
for a full day of event action.
Press
An example on how to set weekend as time mask is as follows:
1. Click from time mask setting.
button to remove a scheduled time period.
2. Enter Mask name, e.g. Weekend.
3. Check “Sun” & “Sat” boxes.
4. Select “Start time” and “End time” or “Full day”.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.7 SYSTEM
Date/Time, Daylight Saving, SD card and Maintenance settings can be performed
on this page.
The "System" page has 4 tabs: the [Date/Time] tab, the [Daylight Saving] tab, the
[SD card] tab and the [Maintenance] tab.
4.7.1 Date/Time
Machine Name Setting
Machine Name: Enter the name of the camera. The entered name will be displayed
in the status display area.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
Set Date/Time Manually
Date: Click the calendar and pick the date. Press << to go previous year, < to go
previous month, > to go next month and >> to go next year.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Time: Click on Hour, Minute, Seconds, am/pm; then use up arrow to increase
value and down arrow to decrease value.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
Set Date/Time Sync.
Check Enable NTP checkbox to enable NTP server.
NTP server: Time automatically adjusted by synchronizing with NTP server will
be used as the standard time of the camera.
Sync. Internal: Select an interval (1 - 24 hours: in 1 hour intervals) of
synchronization with the NTP server.
Time Zone: Select a time zone according to the location where the camera is in use.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.7.2 Daylight Saving
Set Daylight Saving
Check Enable Daylight Saving checkbox to enable daylight saving.
Set the start time to daylight saving time.
Set the start week of daylight saving time: 1st / 2nd / 3rd / 4th / Last
Set the start date of daylight saving time: Sunday / Monday / Tuesday / Wednesday
/ Thursday / Friday / Saturday
Set the start month of daylight saving time: January / February / March / April /
May / June / July / August / September / October / November / December.
Set the starting time change of daylight saving time: Choose the “From” time and
“End” time when daylight saving starts.
Set the end time of daylight saving time.
Set the end week of daylight saving time: 1st / 2nd / 3rd / 4th / Last
Set the end date of daylight saving time: Sunday / Monday / Tuesday / Wednesday
/ Thursday / Friday / Saturday
Set the end month of daylight saving time: January / February / March / April /
May / June / July / August / September / October / November / December.
Set the ending time change of daylight saving time: Choose the “From” time and
49
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
“End” time when daylight saving ends.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
4.7.3 SD Card
Setup SD Card
Notification: Notification will be made via e-mail when the remaining space of the
SD memory card reached the value selected from the following.
50%, 20%, 10%, 5%, 2%, 0%
Note:
1. When "50%" is selected, e-mail notification will be made each time the
remaining space reaches 50%, 20%, 10%, 5%, 2% and 0%.
2. E-mail notification may not always be made at a very moment when the
remaining space of the SD memory card reached the selected value.
Event Recording:
-FTP backup only: Event video will record to SD card when network is
disconnected.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
-Normal: Follow the event actions settings you have made in “Event” menu to
record event video to SD card.
-Overwrite: Select ON for overwriting data when SD card memory is full. Select
OFF for not overwriting SD card data.
Press Apply to apply the setting changes or Reset to reset without saving the
change.
SD Card Utility
The total size and available size of the SD memory card will be displayed.
Depending on the state of the SD memory card, the size indications will differ as
follows.
Indication Description:
Capacity ___ MB, available ___MB, used ___ %
Before formatting the SD memory card, it is necessary to press
button.
Once
button is pressed,
button will be shown for user to
insert the SD card back.
Press
Note:
button to format SD card.
1. It is impossible to access the SD memory card in the process of formatting.
2. All data saved on the SD memory card will be deleted when the SD memory card is
formatted.
3. Do not turn the power of the camera off in the process of formatting.
Obtain images on the SD memory card
1. Go to IE Browser or Windows Command.
password.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
3. Enter administrator user name and password. (user1, 11111111)
4. Then you can download video or image file from SD card. The file name will show
the time of video.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
4.7.4 Serial Communication
RS485 Setting
Camera ID: This entry is used to assign camera own ID code.
Baud Rate: This field is to set the speed at which is used to transmit instruction or
information through the RS485 port on the camera. There are six different speeds,
2400/4800/9600/19200/38400/57600. The default setting from the factory is 9600.
Protocol: Select protocol from EverFocus and Pelco-D. The default setting from the
factory is Pelco-D.
Data Bit: This field is the data bit at which you will be transferring. There are two
settings for this option: 8 or 7. The default is set to 8.
Stop Bit: This field is to set the stop bit for the RS485 connection. There are two
different stop bits, 1 or 2. The default is set to 1.
Parity: This field is to select the parity level at which you will be connected. You can
choose between None, Odd, or Even parity levels. Default is set to none.
53
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Press Apply to apply the setting changes or Reset to reset without saving the change.
4.7.5 Maintenance
Maintenance Server
Reboot: The unit is rebooted without changing any of the settings. Use this method
by pressing Reboot button if the unit is not behaving as expected.
Restore: The unit is restarted and most current settings are reset to the factory
default values by pressing Restore button. The only settings saved are:
•
•
IP setting
DDNS setting
Default: The Default button should be used with caution. Pressing this button will
return all of the camera's settings, including the IP address, to the factory default
values. The camera will then have to be re-installed.
54
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Save/Load Configuration Server
To take a backup of all of the configurations, press Save to save all configurations
to a config. file. If necessary, it is then possible to return to the previous settings if
the settings are changed and there is unexpected behavior.
Press the Browse button to locate the saved config. file (see above) and then click
the Load button. The settings will be restored to the previous configuration.
Upgrade Firmware
Upgrade the EZN850 with the latest firmware.
Press Browse button to search firmware file. Press Upgrade button to upgrade the
firmware.
Note
1. Do not disconnect power to the unit during the upgrade. The unit reboots
automatically after the upgrade has completed. (1-5 minutes.)
2. During upgrading process, all event recording actions will be stopped. It
will continue to record after the camera is rebooted.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
5. SPECIFICATIONS
CAMERA
Pickup Device
Pixel Effective
1/3"Sony super HAD CCD
NTSC: 768 (H) x 494 (V); PAL: 752 (H) x 582 (V)
0.002 Lux / F=1.2 (IR Off, SENS-UP 128x)
Sensitivity
0 Lux (IR On)
Day & Night
Lens
True Day/Night with IR cut filter
Vari-focal 6~50mm, 9x optical zoom
BNC socket, composite 1 V p-p / 75Ω
560 TVL
Video Output
Video Output Resolution
IR Distance
50M / 164 feet
IR Wavelength
IR LED Lifespan
850mm
20,000 hours
VIDEO STREAMING
Video Compression
Video Resolution
Video Quality
H.264/MPEG-4/M-JPEG
D1, VGA, CIF, QVGA, QCIF
8 levels adjustable
Frame Rate
Up to 30fps
NETWORK
10Base-T/100Base-TX auto-negotiation, RJ-45 socket
Support MDI/MDI-X auto crossover function
HTTP, TCP / IP, UDP, RTP, RTSP, FTP, SMTP, DHCP, DNS, DDNS,
NTP
Interface
Supported Protocols
Bandwidth Control
Max. Client Limit
Min. 64 kbps adjustable
32 simultaneous clients
TERMINAL I/O
RS-485
RS-485 interface half-duplex
Alarm I/O
Power Output
1 x input, 1 x output, Normal Open / Normal Closed adjustable
12VDC for external IR illuminator ; Max. load = 1A
EVENT MANAGEMENT
Event Triggered by
Alarm input, Manual trigger, Motion detection and Schedule recording
Trigger alarm output, Send mail notification, Upload video to FTP,
Record video to SD card, Record video to PC and Network alarm
Notification Over
Pre- and Post- alarm Buffer 48MB RAM reserved for pre-alarm record up to 120 sec.
LOCAL STROAGE
Secure Disk physical layer specification version 2.0
Supports SDHC Host Specification
SD Card
POWER
Power Supply
24VAC ; 100VAC~240VAC
24VAC: 28W max. (Heater/ON & IR LED/ON) ;
100VAC~240VAC: 8W max. (Heater/ON & IR LED/ON)
Power Consumption
PHYSICAL
Dimensions
295 mm (W) x 115 mm (H) ; 11.8” (W) x 4.5” (H)
56
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
Weight
2.5kg ; 5.5lbs (3.0kg ; 6.6LBS with bracket)
ENVIRONMENTAL
Operating Temp.
Humidity
-40°C ~ 50°C ; -40°F ~ 122°F
20~80%
Yes
Heater
Weatherproof Ratings
Vandal Proof
IP66
Yes
57
Download from Www.Somanuals.com. All Manuals Search And Download.
EZN850
EverFocus Electronics Corp.
Head Office:
Europe Office:
12F, No.79 Sec. 1 Shin-Tai Wu Road,
Hsi-Chih, Taipei, Taiwan
TEL: +886-2-26982334
FAX: +886-2-26982380
Albert-Einstein-Strasse 1
D-46446 Emmerich, Germany
TEL: +49(0)-2822-9394-0
FAX: +49(0)-2822-9394-95
USA L.A. Office:
1801 Highland Ave. Unit A
Duarte, CA 91010, U.S.A.
TEL: +1-626-844-8888
FAX: +1-626-844-8838
China Office:
Room B-05D-1, KESHI PLAZA, Shangdi
Information Industry Base,
Haidian District, Beijing China
100085
TEL: +86-10-62973336/37/38/39
FAX: +86-10-62971423
USA N.Y. Office:
415 Oser Avenue Unit S
Hauppauge, NY 11788
TEL: +1-631-436-5070
FAX: +1-631-436-5027
Japan Office:
1809 WBG MARIBU East 18F,
2-6 Nakase.Mihama-ku.
Chiba city 261-7118, Japan
TEL: +81-43-212-8188
FAX: +81-43-297-0081
Your EverFocus product is designed and
manufactured with high quality materials and
components which can be recycled and reused.
This symbol means that electrical and electronic
equipment, at their end-of-life, should be
disposed of separately from your household
waste.
Please, dispose of this equipment at your local
community waste collection/recycling centre.
In the European Union there are separate
collection systems for used electrical and
electronic product.
Please, help us to conserve the environment we
live in!
Ihr EverFocus Produkt wurde entwickelt und
hergestellt mit qualitativ hochwertigen Materialien
und Komponenten, die recycelt und wieder
verwendet werden können.
Dieses Symbol bedeutet, dass elektrische und
elektronische Geräte am Ende ihrer Nutzungsdauer
vom Hausmüll getrennt entsorgt werden sollen.
Bitte entsorgen Sie dieses Gerät bei Ihrer örtlichen
kommunalen Sammelstelle oder im Recycling
Centre.
Helfen Sie uns bitte, die Umwelt zu erhalten, in der
wir leben!
Download from Www.Somanuals.com. All Manuals Search And Download.
|