Electric Dryer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
EED4300V
EED4400V
22³⁄₄"
(57.8cm)
15¹⁄₄"
(38.74cm)
43³⁄₈"
Electrical: A four-wire or three-wire, single
phase, 120-volt, 60 Hz, AC-only, electrical supply
is required on a separate 15 or 20 amp circuit,
fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do Not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
43³⁄₈"
(110cm)
A. Small Opening
Side-Swing Door
(110cm)
B. Large Opening
Side-Swing Door
*27³⁄₄"
*26"
(66cm)
(70.5cm)
29"
29"
(73.66cm)
(73.66cm)
B
A
22³⁄₄"
(57.8cm)
C. Wide Opening
Side-Swing Door
43³⁄₈"
43³⁄₈"
(110cm)
(110cm)
13³⁄₄"
D. Wide Opening
Hamper Door
(34.9cm)
*27³⁄₄"
*27³⁄₄"
(70.5cm)
(70.5cm)
29"
29"
(73.66cm)
(73.66cm)
C
D
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for exhaust
vent with elbow.
RECESSED AREA AND CLOSET INSTALLATION
For closet installation
3"
(7.6 cm)
with a door, minimum
ventilation openings in
the top and bottom of
the door are required.
Louvered doors with
equivalent air openings
are acceptable.
14" max.
(35.6cm)
48 in. 2
(310 cm2 )
18"
(45.7 cm)
24 in.2
3"
(7.6 cm)
(155 cm2 )
1"
(2.5 cm)
29"
(73.66 cm)
5¹⁄₂"
(14 cm)
1"
1" 27³⁄₄"
(2.5 cm)(2.5 cm)(70.5 cm)
EXHAUST VENTING
B
C
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
4"
(10.2 cm)
Box hood style
4"
(10.2 cm)
2.5"
1. Select the route that will provide the straightest and most direct path outdoors. Plan
the installation to use the fewest number of elbows and turns. When using elbows or
making turns, allow as much room as possible. Bend vent gradually to avoid kinking.
Avoid 90° turns.
(6.4 cm)
4"
(10.2 cm)
Angled style
Louvered style
Vent Length Chart
2. Determine vent length.
Number of
90° turns
or elbows
Type of
vent
Box or
Louvered
hoods
Angled
hoods
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent
lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
0
1
2
3
4
Rigid metal
Flexible metal 36 ft (11 m)
64 ft (20 m)
58 ft (17.7 m)
28 ft (8.5 m)
Rigid metal
Flexible metal
54 ft (16.5 m)
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
Rigid metal
Flexible metal 27 ft (8.2 m)
44 ft (13.4 m) 38 ft (11.6 m)
19 ft (5.8 m)
Rigid metal
Flexible metal 25 ft (7.6 m)
35 ft (10.7 m) 29 ft (8.8 m)
17 ft (5.2 m)
In the column listing the type of metal vent you are using (rigid metal or flexible metal),
find the maximum length of metal vent on the same line as the number of elbows.
Rigid metal
Flexible metal 23 ft (7 m)
27 ft (8.2 m)
21 ft (6.4 m)
15 ft (4.6 m)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10150612
04-18-08