Elation Professional Work Light 72MKII User Manual

Design LED 72MKII  
Elation Professional™  
6122 S. Eastern Ave.  
Los Angeles, Ca 90040  
Rev. 09/15/2008 - visage  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
1. GENERAL INFORMATION  
INTRODUCTION: Congratulations, you have just purchased one of the most innovative and  
reliable LED fixtures on the market today! The Design LED 72MKII™ has been designed to  
perform reliably for years when the guidelines in this booklet are followed. Please read and  
understand the instructions in this manual carefully and thoroughly before attempting to  
operate this unit. These instructions contain important information regarding safety during  
use and maintenance.  
UNPACKING: Thank you for purchasing the Design LED 72MKII™ by Elation Professional®.  
Every Design LED 72MKII™ has been thoroughly tested and has been shipped in perfect  
operating condition. Carefully check the shipping carton for damage that may have occurred  
during shipping. If the carton appears to be damaged, carefully inspect your fixture for  
damage and be sure all accessories necessary to operate the fixture have arrived intact. In  
the event damage has been found or parts are missing, please contact our customer support  
team for further instructions. Inside the box you should find: the fixture, a DMX XLR cable, a  
safety cable, and this manual. Please do not return this unit to your dealer without first  
contacting customer support at the number listed below.  
CUSTOMER SUPPORT: Elation Professional® provides a customer support line, to provide  
set up help and to answer any question should you encounter problems during your set up  
comments or suggestions. For service related issue please contact Elation Professional®.  
Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m. Pacific Standard Time.  
Voice:  
Fax:  
(323) 582-3322  
(323) 832-9142  
E-mail:  
Forum:  
Warning! To prevent the risk of fire and reduce the risk electrical shock do not attempt to  
operate this fixture with the lens cover removed.  
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs  
©Elation Professional, Los Angeles Ca.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
yourself. Doing so will void your manufactures warranty.  
Please do not discard the shipping carton in the trash. Please recycle whenever possible.  
WARRANTY REGISTRATION: The Design LED 72MKII™ carries a two year (730 days)  
limited warranty. Please fill out the enclosed warranty card to validate your purchase. All  
returned service items whether under warranty or not, must be freight pre-paid and  
accompany a return authorization (R.A.) number. The R.A. number must be clearly written  
on the outside of the return package. A brief description of the problem as well as the R.A.  
number must also be written down on a piece of paper and included in the shipping  
container. If the unit is under warranty, you must provide a copy of your proof of purchase  
invoice. Items returned without a R.A. number clearly marked on the outside of the package  
will be refused and returned at customer’s expense. You may obtain a R.A. number by  
contacting customer support at (323) 582-3322.  
©Elation Professional, Los Angeles Ca.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
2. SAFETY INSTRUCTIONS  
To guarantee proper and consistent operation, it is important to  
follow the guidelines in this manual. Elation Professional will not  
accept responsibility for damages resulting from the misuse of  
this fixture due to the disregard of the information printed in this  
manual.  
1. This fixture has been specially designed for use outdoors. Altering or tampering  
with the fixture housing in any way will neglect the IP rating and subsequently  
release Elation Professional from any liability resulting from misuse of this  
fixture.  
2. Allow about 6” (15cm) between this fixture and other devices or a wall to allow  
for proper cooling. See page 8.  
3. Never touch the fixture during normal operation.  
4. Never look directly into the light source. You risk injury to your retina, which may  
induce blindness.  
5. For safe operation, follow the Installation guide described in chapter six of this  
manual. Operating the Design LED 72MKII™ without suited safety aids such as  
safety cables or clamps can increase the risk of damage and/or personal injury.  
6. Qualified and certified personnel should only perform installation.  
7. When mounting this fixture, use only the original rigging points included with this  
fixture. Any structural modification will void the original manufactures warranty  
and may increase the risk of damage and/or personal injury.  
8. Do not attempt to operate this fixture if the power cord has become damaged or  
frayed.  
9. Never open this fixture while in use.  
10.This device falls under protection-class I. Therefore it is essential that the device  
be grounded properly.  
11.Qualified personnel should perform all electrical connections.  
©Elation Professional, Los Angeles Ca.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
12.Be sure the power cord is never crimped or damaged. If the power cord is  
damaged, replace it immediately with a new one of similar power rating.  
13.Always disconnect from main power before performing any type of service or  
any cleaning procedure.  
14.Only handle the power cord by the plug. Never pull out the plug by tugging the  
wire portion of the cord.  
15.Please be aware that damages caused by modifications to the device are  
not subject to warranty.  
Important Notice: Damages resulting from the disregard of safety and general user  
instructions found in this user manual are not subject to any warranty claims.  
©Elation Professional, Los Angeles Ca.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
3. FEATURES  
Low power consumption  
Minimal heat emission  
Maintenance free operation  
Equipped with 72 Luxeon K2 3-Watt (24 x red, 24 x green, 24 x blue)  
IP65 Rated for outdoor wet conditions  
Silent Operation, convection cooled, no fans  
100,000 hours rated LED life  
Linear RGB Color Mixing, infinite color possibilities  
53˚ Standard Beam Angle  
USITT DMX-512 Complaint  
Preprogrammed colored macros  
Strobe-effect with a maximum flash rate of 18fps  
DMX-controlled operation or stand-alone operation with Master/Slave-function  
8 built-in programs can be called up via DMX-controller  
~ 48 preprogrammed scenes per program  
Sound-controlled via built-in microphone  
Four DMX Modes:  
15 DMX channels  
6 DMX channels  
4 DMX channels  
3 DMX channels  
DMX-control via standard DMX-controller  
IP65 rated Connectors for power and DMX  
Switching Electronic Power Supply 100v~240v  
Flicker-free operation for television and film  
Compact case design  
0%~100% Dimming (two dimming options; linear & standard)  
©Elation Professional, Los Angeles Ca.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
4. GENERAL GUIDELINES  
This fixture is a professional lighting effect designed for outdoor architectural installations.  
Do not attempt operation or installation without a proper knowledge on how to do so.  
Consistent operational breaks will ensure that the fixture will function properly for many  
years to come.  
Do not shake the fixture around. Avoid brute force when installing or operating the fixture.  
While choosing an installation location, please be sure that the fixture will not be exposed to  
extreme heat. The minimum distance between the fixture and a wall or flat surface should be  
at least 0.5 meter (about 1.5ft). See page 11.  
Always install the fixture with an appropriately rated safety cable. When installing the fixture  
in a suspended environment always be sure to use mounting hardware no less than M10 x  
25 mm, also be sure the hardware is only inserted in the yoke’s mounting holes.  
Do not attempt to operate this fixture until you have familiarized yourself with all of its  
functions.  
Do not permit operation by persons not qualified for operating this type of architectural  
fixture. Most damages are the result of improper operation.  
Please use the original packaging to transport the fixture in for service.  
For your own safety, please read this user manual carefully before installing the device.  
©Elation Professional, Los Angeles Ca.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
5. FIXTURE OVERVIEW  
©Elation Professional, Los Angeles Ca.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
1. Yoke Assembly – This yoke is designed to perform two functions; 1) When split it  
can be used as a floor stand bracket. 2) Used to secure a mounting clamp for truss  
mounting.  
2. LED Lens Assembly – The lens assembly may be user replaced in the event repair  
is needed or a different beam angle is required.  
3. DMX In Lead – This lead is the main DMX input lead. When the unit is the first in a  
chain or the only fixture to be used with a DMX controller, be sure to use the DMX  
starter cable that converts a standard 3-pin XLR DMX connector to the IP rated twist  
lock connector that is used on the fixture. When jumping from fixture to fixture be  
sure to only use Elation IP rated DMX cables to maintain the IP rating.  
4. DMX Out Lead – This lead is used to send an incoming DMX signal to the next  
fixture in the DMX chain. To maintain the integrity of the IP rating, only use proper  
Elation IP rated DMX cables.  
5. Menu Button – This button is used to access the fixtures menu functions.  
6. Up Button – The up button is used to toggle forward through the menu functions and  
settings.  
7. LED Display – 4-segment menu display. Used to display the DMX address as well  
as all other menu functions.  
8. Down Button – The down button is used to toggle backwards through the menu  
functions and settings.  
9. Enter Button – The enter button is used to enter in to a certain menu function or to  
lock a menu setting in to memory.  
©Elation Professional, Los Angeles Ca.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
10. Power Output Lead – This lead is used to jump power to another Design LED  
72MKII™. Please do not daisy-chain power for more than 16 fixtures. To maintain  
the integrity of the IP rating, only use proper Elation IP rated power cables.  
11. Main Power Input Lead – This lead is the main power input lead. When the unit is  
the first in a chain or the only fixture to be used, be sure to use the power starter  
cable that converts a standard Edison 3-prong to the IP rated twist lock connector.  
When jumping from fixture to fixture be sure to only use Elation IP rated power  
connectors to maintain the IP rating.  
©Elation Professional, Los Angeles Ca.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
6. MOUNTING AND INSTALLATION  
Cautions:  
For added protection mount the fixtures in areas outside walking paths, seating areas, and  
away from areas were unauthorized personnel might reach the fixture.  
Before mounting the fixture to any surface, make sure that the installation area can hold a  
minimum point load of 10 times the device’s weight.  
Fixture installation must always be secured with a secondary safety attachment, such as an  
appropriate safety cable.  
To avoid injury, never stand directly below the device when mounting, removing, or servicing  
the fixture.  
Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE0711-217  
for proper installation in Europe To ensure proper installation, only  
qualified staff should attempt installation.  
Mounting points  
Overhead mounting requires extensive experience, including amongst others calculating  
working load limits, a fine knowledge of the installation material being used, and periodic  
safety inspection of all installation material and the fixture. If you lack these qualifications, do  
not attempt the installation yourself. Improper installation can result in bodily injury.  
CAUTION!  
Be sure a qualified electrician performs all electrical  
connections.  
Be sure to complete all rigging and installation procedures before connecting the main  
power cord to the appropriate wall outlet.  
©Elation Professional, Los Angeles Ca.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
Mounting  
The Design LED 72MKII™ is fully operational in any mounting position, hanging  
upside-down, side mounted, or set on a flat level surface, etc. Be sure this fixture is kept at  
least 0.5m (1.5 feet) away from any flammable materials (decoration etc.). When clamp  
mounting; always use and install the supplied safety cable as an added safety measure to  
prevent accidental damage in the event of a clamp failure. See the image below.  
Clamp Mounting  
The Design LED 72MKII™ provides a unique mounting bracket assembly that allows the unit  
to stand on a flat surface or to be hung on truss via a clamp in any safe position (see the  
illustration above). Regardless of the mounting option you choose please be sure to refer to  
the safety guidelines in this manual to avoid damage to the unit and/or personal injury.  
©Elation Professional, Los Angeles Ca.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
When mounting this fixture to truss be sure to secure an appropriately rated clamp to the  
hanging yoke using a M10 screw fitted through the center hole of the hanging yoke. As an  
added safety measure be sure to attach at least one properly rated safety cable to the fixture.  
See illustrations below.  
Securing the Design LED 72MKII™  
Always be sure to secure your fixture with a safety cable when  
suspending the unit from truss or other means. The fixture  
provides a built-in rigging point for a safety cable as illustrated  
above. Be sure to only use the designated rigging point for the  
safety cable and never secure a safety cable to the hanging  
bracket.  
©Elation Professional, Los Angeles Ca.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
7. UNDERSTANDING DMX  
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most  
lighting and controller manufactures as a form of communication between intelligent fixtures  
and controllers. DMX allows all makes and models of different manufactures to be linked  
together and operate from a single controller. This is possible as long as all the fixtures and  
the controller are DMX compliant. A DMX controller sends the DMX data instructions to a  
fixture allowing the user to control the different aspects of an intelligent light. DMX data is  
sent out as serial data that travels from fixture to fixture via data “IN” and “OUT” leads  
located on the fixtures (most controllers will only have output jacks).  
DMX Linking: To ensure proper DMX data transmission, always use proper DMX cables  
and a terminator. When using several DMX fixtures try to use the shortest cable path  
possible. Never split a DMX line with a “Y” style connector. The order in which the fixtures  
are connected in a DMX line does not influence the DMX addressing. For example; a fixture  
assigned a DMX address of 1 may be placed anywhere in the DMX chain, at the beginning,  
at the end, or anywhere in the middle. The DMX controller knows to send data assigned to  
address 1 to that fixture no matter where it is located in the DMX chain. The Design LED  
72MKII™ can be controlled via DMX-512 protocol. The Design LED 72MKII™ is a fixture  
that can operate in 3, 4, 6, or 15 DMX channels (see page 21 for the different DMX traits).  
The DMX address is set electronically using the controls on the LED menu.  
Cable Requirements: This fixture is designed with special cables for both DMX and power.  
These cables are specifically designed to maintain the integrity of the IP rating. When using  
this fixture outdoors be sure to ONLY use the Elation cables that have been manufactured to  
meet the IP rating.  
“First” DMX Cables - Special DMX “First” cables may be purchased from Elation to provide  
a means of data communication with standard DMX fixtures for indoor use. These cables will  
come with the IP rated twist lock connector on one end and either a 3-pin XLR male or  
female connector on the other depending on model. Be sure to only use these cables for  
intergrading this fixture in a standard DMX chain.  
©Elation Professional, Los Angeles Ca.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
“First” Power Cable – A special power “First” cable is included with every fixture. This  
cables is used to provide power to your fixture. This cable comes with the IP rated twist lock  
connector on one end and a standard Edison 3-prong, grounded prong on the other end. Be  
sure to only use this cable for power distribution and never attempt to connect this cable to  
the DMX lines.  
You can chain multiple fixtures together through serial linking. Using the IP rated signal  
cables provided through Elation. Always be sure to daisy-chain your in and out data  
connections, never split or “Y” your DMX connections unless you are using an approved  
DMX splitter such as the Elation Opto Branch 4™ or DMX Branch/4™.  
DMX-512 connection with DMX terminator  
A DMX terminator should be used in all DMX lines especially in longer runs. The use of a  
terminator may avoid erratic behavior in your DMX line. A terminator is a 120 ohm 1/4 watt  
resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA  
-). This fixture is inserted in the female XLR connector of the last fixture in your daisy chain  
to terminate the line. Using a line terminator (Elation part: DMX T PACK) will decrease the  
possibilities of erratic behavior.  
©Elation Professional, Los Angeles Ca.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA  
transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX  
line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must  
be used, these adaptors are readily available at most electric stores. The following chart  
details a proper cable conversion.  
Fixture DMX addressing;  
All fixtures should be given a DMX starting address when using a DMX controller, so the  
correct fixture responds to the correct control signal. This digital starting address is the  
channel number from which the fixture starts to “listen” to the digital control information sent  
out from the DMX controller. The allocation of this starting DMX address is achieved by  
setting the correct DMX address on the digital display located on the back of the fixture.  
You can set the same starting address for all fixtures or a group of fixtures, or set different  
address for each individual fixture. Be advised that setting all you fixtures to the same DMX  
address will subsequently control all fixtures in the same fashion, in other words, changing  
the settings of one channel will affect all the fixtures simultaneously.  
If you set each fixture to a different DMX address, each unit will start to “listen” to the  
channel number you have set, based on the quantity of control channels (DMX channels) of  
each fixture. That means changing the settings of one channel will only affect the selected  
fixture.  
©Elation Professional, Los Angeles Ca.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
In the case of the Design LED 72MKII™, which is capable of controlling up to 15 DMX  
channels, you should set the starting DMX address of the first unit to 1, the second unit to 16  
(15 + 1), the third unit to 31 (15 + 16), and so on.  
Note: During start-up the Design LED 72MKII™ will automatically detect whether a DMX  
data signal is being received or not. If a DMX data signal is being received, the display will  
show "A.XXX" (XXX representing the actual DMX address). If the fixture is not receiving a  
DMX signal the display will flash "A.XXX" (XXX representing the actual DMX address).  
If your fixture is connected to a DMX controller and the display is flashing (not receiving a  
DMX signal), please check the following:  
-
The 3-pin or 5-pin XLR plug (cable with DMX signal from controller) may not be  
connected or is not inserted completely into the DMX input jack.  
The DMX IP cable adapter is fitted incorrectly.  
-
-
-
-
The DMX controller is switched off or defective.  
The DMX cable or connector is defective.  
A DMX terminator has been inserted into the last fixture in your DMX chain.  
©Elation Professional, Los Angeles Ca.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
8. DISPLAY LED INDICATORS.  
The Design LED 72MKII ™ has two LED indicators on the display. These indicators are  
designed to give a quick visual indication of the fixtures’ status. The illustration below details  
the functionality of the LED indicators.  
. .  
.
.
DMX OK  
NO DMX  
DMX OK  
Lamp off  
NO DMX  
Lamp off  
Lamp on  
Lamp on  
The first LED indicators represents DMX signal:  
• If the indicators is on a clean DMX signal is present  
• If the indicator is off there is no DMX signal present  
The second LED indicator represents lamp condition; this is only applicable to fixtures with  
traditional lamp sources.  
©Elation Professional, Los Angeles Ca.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
9. MENU  
Default settings shaded.  
<DMX ADDRESS>  
DMX CHANNEL: 1-512  
3 CHANNEL MODE  
4 CHANNEL MODE  
6 CHANNEL MODE  
15 CHANNEL MODE  
ON/OFF  
SET DMX ADDRESS  
3 DMX CHANNELS (RGB)  
4 DMX CHANNELS (RGB+MASTER DIM)  
6 DMX CHANNELS  
15 DMX CHANNELS  
<DMX OPERATION MODE>  
<SET AS SLAVE>  
UNIT FUNCTIONS AS SLAVE  
UNIT FUNCTIONS AS MASTER  
UNIT FUNCTIONS IN STAND ALONE  
MASTER  
<MANUAL OPERATION MODE>  
STAND ALONE  
<BLACK OUT>  
PRESET VALUE: XXX  
RED VALUE  
GREEN VALUE  
BLUE VALUE  
STROBE  
SPEED  
SET RED VALUE  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
SET GREEN VALUE  
NEW VALUE: 0-255  
<SET STATIC COLOR>  
PRESET VALUE: XXX  
SET BLUE VALUE  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
SET STROBE VALUE  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
CHASE 1  
CHASE 2  
CHASE 3  
CHASE 4  
FADE  
STROBE  
SPEED  
FADE  
STROBE  
SPEED  
FADE  
STROBE  
SPEED  
FADE  
STROBE  
SPEED  
CHASE 5  
CHASE 6  
FADE  
STROBE  
SPEED  
FADE  
©Elation Professional, Los Angeles Ca.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
STROBE  
SPEED  
NEW VALUE: 0-256  
PRESET VALUE: XXX  
NEW VALUE: 0-256  
PRESET VALUE: XXX  
NEW VALUE: 0-256  
PRESET VALUE: XXX  
NEW VALUE: 0-256  
PRESET VALUE: XXX  
NEW VALUE: 0-256  
PRESET VALUE: XXX  
NEW VALUE: 0-256  
EDIT SCENE # XX  
FADE  
CHASE 7  
STROBE  
SPEED  
FADE  
CHASE 8  
STROBE  
SET CHANNEL  
EDIT CHANNEL # XX  
VALUE  
PROGRAM SCENE BY  
ON-BOARD CONTROLS  
DOWNLOAD SCENE  
FROM CONTROLLER  
START SCENE LOOP  
(ENTER)  
XXX  
<EDIT SCENES>  
SELECT SCENE # XX  
SAVE (ENTER)  
SCENE LOOP PLAYS FROM FIRST TO LAST  
SCENES  
PREVIOUS SCENE #  
XXX  
SET START SCENE  
SET FIRST SCENE FOR SCENE LOOP  
NEW SCENE # XXX  
PREVIOUS SCENE #  
XXX  
SET END SCENE  
SPEED  
SET LAST SCENE FOR SCENE LOOP  
SET SCENE LOOP SPEED  
<PLAY SCENES>  
<DIMMER MODE>  
NEW SCENE # XXX  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
PRESET VALUE: XXX  
NEW VALUE: 0-255  
FADE  
SET SCENE LOOP FADE  
MODE 1 (ENTER)  
MODE 2 (ENTER)  
YES (ENTER)  
STANDARD DIMMING OPTION  
LINEAR DIMMING OPTION  
<FACTORY RESET>  
RESTORE FACTORY DEFAULT SETTINGS  
<SOFTWARE VERSION>  
V X.X  
DISPLAY'S CURRENT SOFTWARE VERSION  
NOTICE:  
1) If the fixture does not receive a DMX signal the menu display will flash repeatedly.  
2) The “SPED” and “FADE” function only work when the fixture is operating via one of the  
internal chase programs.  
3) SPED: Adjust the hold time for each scene in built-in chase programs.  
4) FADE: Adjust the fade time between each scene in the built-in programs.  
5) This fixture will automatically retain the last DMX command in the event of DMX failure.  
©Elation Professional, Los Angeles Ca.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
10.DMX TRAITS  
DMX Operation Notes:  
The fixture will function in DMX mode whenever the unit is receiving a DMX signal. Please  
note that this will override all manual settings.  
This unit will keep and retain the last DMX command in the event of DMX signal failure. To  
reset the fixture you must turn the power off.  
DMX CHANNEL TRAITS  
The charts below and on the preceding pages outline the different DMX traits for the three  
different DMX modes.  
3-Channel mode: In this mode channel one controls all the red LEDs, channel two controls  
all the green LEDs, and channels three controls all the blue LEDs.  
CHANNEL 1:Red  
CHANNEL 2:Green  
CHANNEL 3:Blue  
3-Channel Mode: The chart below details the DMX channel layout for 3-channel assignment.  
DMX channel’s functions and their values (3-Channel Mode):  
Channel 1 - Red:  
0-255  
Red (0-Black, 255 - 100% Red)  
Channel 2 - Green:  
0-255  
Green (0-Black, 255 - 100% Green)  
Channel 3 - Blue:  
0-255  
Blue (0-Black, 255 - 100% Blue)  
©Elation Professional, Los Angeles Ca.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
4-Channel mode: In this mode channel one controls all the red LEDs, channel two controls  
all the green LEDs, channels three controls all the blue LEDs, and channel four-- will control  
the master dimming level.  
CHANNEL 1:Red  
CHANNEL 2:Green  
CHANNEL 3:Blue  
CHANNEL 4:Dimmer/Speed  
4-Channel Mode: The chart below details the DMX channel layout for 4-channel assignment.  
DMX channel’s functions and their values (4-Channel Mode):  
Channel 1 - Red:  
0-255  
Red (0-Black, 255 - 100% Red)  
Channel 2 - Green:  
0-255  
Green (0-Black, 255 - 100% Green)  
Channel 3 - Blue:  
0-255  
Blue (0-Black, 255 - 100% Blue)  
Channel 4 - Dimming / Program Speed Control  
This channel has two functions depending on the operating mode. When running the built-in  
programs this channel will control the program speed.  
0-255  
0-255  
Dimming (0%-100%) ~ Normal Operation  
Speed (min to max) ~ When running built-in programs on channel 4  
©Elation Professional, Los Angeles Ca.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
6-Channel mode: In this mode channels 1~3 are used to control the RGB LEDs and  
channels 4~6 will control special features.  
CHANNEL 1:Red  
CHANNEL 2:Green  
CHANNEL 3:Blue  
CHANNEL 4:Auto Programs (Built-in Programs)  
CHANNEL 5:Strobe  
CHANNEL 6:Dimmer/Speed  
6-Channel Mode: The charts below and on the next page detail the DMX channel layout for  
6-channel assignment.  
DMX channel’s functions and their values (6-Channel Mode):  
Channel 1 - Red:  
0-255  
Red (0-Black, 255-100% Red)  
©Elation Professional, Los Angeles Ca.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
Channel 2 - Green:  
0-255  
Green (0-Black, 255- 100% Green)  
Channel 3 - Blue:  
0-255  
Blue (0-Black, 255- 100% Blue)  
Channel 4 - Internal programs:  
0-10  
No function  
11-40  
Internal program 1  
Internal program 2  
Internal program 3  
Internal program 4  
Internal program 5  
Internal program 6  
Internal program 7  
Internal program 8  
41-70  
71-100  
101-130  
131-160  
161-190  
191-220  
221-255  
Channel 5 - Strobe:  
0
No function  
1~95  
Strobe effect slow to fast  
No function  
96-127  
128-159  
160-191  
192-223  
224-255  
Pulse effect in sequences  
No function  
Random strobe effect slow to fast  
No function  
Channel 6 - General dimming / Program Speed Control  
This channel has two functions depending on the operating mode. When running the built-in  
programs this channel will control the program speed, when not running the built-in programs  
this channel will control master dimming.  
0-255  
0-255  
Dimming (0%-100%) ~ Normal Operation  
Speed (min to max) ~ When running built-in programs on channel 4  
©Elation Professional, Los Angeles Ca.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
15-Channel mode: In this mode channels 1~12 are used to control the RGB LEDs and  
channels 13~15 will control special features.  
CHANNEL 1:Red  
CHANNEL 2:Green  
CHANNEL 3:Blue  
CHANNEL 4:Red  
CHANNEL 5:Green  
CHANNEL 6:Blue  
CHANNEL 7:Red  
CHANNEL 8:Green  
CHANNEL 9:Blue  
CHANNEL 10:Red  
CHANNEL 11:Green  
CHANNEL 12:Blue  
CHANNEL 13:Auto Programs (Built-in Programs)  
CHANNEL 14:Strobe  
CHANNEL 15:Dimmer/Speed  
15-Channel Mode: The charts below and on the next page detail the DMX channel layout for  
15-channel assignment.  
CH14 CH15  
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13  
Reset  
Dimming  
Strobe  
and  
R
G
B
R
G
B
R
G
B
R
G
B
program  
speed  
DMX channel’s functions and their values (6-Channel Mode):  
Channel 1 - Red:  
0-255  
Channel 2 - Green:  
0-255 Green (0-Black, 255- 100% Green)  
Red (0-Black, 255-100% Red)  
©Elation Professional, Los Angeles Ca.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
Channel 3 - Blue:  
0-255  
Blue (0-Black, 255- 100% Blue)  
Channel 4 - Red:  
0-255  
Red (0-Black, 255-100% Red)  
Channel 5 - Green:  
0-255  
Green (0-Black, 255- 100% Green)  
Channel 6 - Blue:  
0-255  
Blue (0-Black, 255- 100% Blue)  
Channel 7 - Red:  
0-255  
Red (0-Black, 255-100% Red)  
Channel 8 - Green:  
0-255  
Green (0-Black, 255- 100% Green)  
Channel 9 - Blue:  
0-255  
Blue (0-Black, 255- 100% Blue)  
Channel 10 - Red:  
0-255  
Red (0-Black, 255-100% Red)  
Channel 11 - Green:  
0-255  
Green (0-Black, 255- 100% Green)  
Channel 12 - Blue:  
0-255  
Blue (0-Black, 255- 100% Blue)  
Channel 13 - Internal programs:  
0-10  
No function  
11-40  
41-70  
71-100  
Internal program 1  
Internal program 2  
Internal program 3  
©Elation Professional, Los Angeles Ca.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
101-130  
131-160  
161-190  
191-220  
221-255  
Internal program 4  
Internal program 5  
Internal program 6  
Internal program 7  
Internal program 8  
Channel 14 - Strobe:  
0
No function  
1~95  
Strobe effect slow to fast  
No function  
96-127  
128-159  
160-191  
192-223  
224-255  
Pulse effect in sequences  
No function  
Random strobe effect slow to fast  
No function  
Channel 15 - General dimming / Program Speed Control  
This channel has two functions depending on the operating mode. When running the built-in  
programs this channel will control the program speed, when not running the built-in programs  
this channel will control master dimming.  
0-255  
0-255  
Dimming (0%-100%) ~ Normal Operation  
Speed (min to max) ~ When running built-in programs on channel 13  
©Elation Professional, Los Angeles Ca.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
11. CLEANING AND MAINTENANCE  
Consider the following points during normal service and inspection:  
1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may  
fall out during normal operation resulting in damage or injury as larger parts could fall.  
2. Electric power supply cables must not show any damage, material fatigue or  
sediments. Never remove the ground prong from the power cable.  
Further instructions depending on the installation spot and usage have to be adhered by a  
skilled installer and any safety problems have to be removed.  
Disconnect from mains before starting maintenance operation.  
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never  
use alcohol or solvents.  
There are no user serviceable parts inside this fixture, please refer all other service issues to  
an authorized Elation service technician.  
Should you need any spare parts, please order genuine parts from your local dealer.  
©Elation Professional, Los Angeles Ca.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
12.  
2-YEAR LIMITED WARRANTY  
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional®  
products to be free of manufacturing defects in material and workmanship for a period of two  
years, (730 days) from the date of purchase. This warranty shall be valid only if the product  
is purchased within the United States of America, including possessions and territories. It is  
the owner’s responsibility to establish the date and place of purchase by acceptable  
evidence, at the time service is sought.  
B. For warranty service, send the product only to the Elation Professional® factory. All  
shipping charges must be pre-paid. If the requested repairs or service (including parts  
replacement) are within the terms of this warranty, Elation Professional® will pay return  
shipping charges only to a designated point within the United States. If the entire instrument  
is sent, it must be shipped in its original package. No accessories should be shipped with the  
product. If any accessories are shipped with the product, Elation Professional® shall have no  
liability what so ever for loss of or damage to any such accessories, nor for the safe return  
thereof.  
C.  
This warranty is void if the serial number has been altered or removed; if the product is  
modified in any manner which Elation Professional® concludes, after inspection, affects the  
reliability of the product; if the product has been repaired or serviced by anyone other than  
the Elation Professional® factory unless prior written authorization was issued to purchaser  
by Elation Professional®; if the product is damaged because not properly maintained as set  
forth in the instruction manual.  
D. This is not a service contract, and this warranty does not include maintenance, cleaning  
or periodic check-up. During the period specified above, Elation Professional® will replace  
defective parts at its expense, and will absorb all expenses for warranty service and repair  
labor by reason of defects in material or workmanship. The sole responsibility of Elation  
Professional® under this warranty shall be limited to the repair of the product, or replacement  
thereof, including parts, at the sole discretion of Elation Professional®. All products covered  
by this warranty were manufactured after January 1, 1990, and bare identifying marks to that  
©Elation Professional, Los Angeles Ca.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
effect.  
E. Elation Professional® reserves the right to make changes in design and/or improvements  
upon its products without any obligation to include these changes in any products  
theretofore manufactured.  
F. No warranty, whether expressed or implied, is given or made with respect to any  
accessory supplied with products described above. Except to the extent prohibited by  
applicable law, all implied warranties made by Elation Professional® in connection with this  
product, including warranties of merchantability or fitness, are limited in duration to the  
warranty period set forth above. And no warranties, whether expressed or implied, including  
warranties of merchantability or fitness, shall apply to this product after said period has  
expired. The consumer’s and or Dealer’s sole remedy shall be such repair or replacement as  
is expressly provided above; and under no circumstances shall Elation Professional® be  
liable for any loss or damage, direct or consequential, arising out of the use of, or inability to  
use, this product.  
G. This warranty is the only written warranty applicable to Elation Professional® Products  
and supersedes all prior warranties and written descriptions of warranty terms and  
conditions heretofore published.  
©Elation Professional, Los Angeles Ca.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
13.  
PHOTOMETRIC DATA  
©Elation Professional, Los Angeles Ca.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
14.  
DIMENSIONAL DRAWINGS  
©Elation Professional, Los Angeles Ca.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
15.  
CIRCUIT SCHEMATIC  
©Elation Professional, Los Angeles Ca.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGN LED 72MKII™  
16.  
TECHNICAL SPECIFICATIONS  
Power supply:  
100v~240v / 50Hz~60Hz AC  
Maximum 150w  
Power consumption:  
LED Configuration:  
72 Luxeon K2, 3 Watts Each  
(24 x Red, 24 x Green 24 x Blue)  
IP65  
IP Rating:  
Weight:  
12 Kgs  
DMX Channels:  
DMX Drive:  
15, 6, 4, or 3 Channel mode  
Standard DMX-512,  
3 pole IP Rated Locking Connector; [+] = Pin 3 [-] = Pin 2  
[Ground] = Pin 1.  
Color Mixing:  
Beam Angle:  
Fuse:  
RGB Color Additive Mixing  
53˚  
GMA 220v~4A (Internal)  
Dimmer:  
Continuous Dimming 0~100%  
Electronic Strobe 0~18 Fps  
100,000 Hours Rated Life  
(377 x 341 x 198) mm, bracket up  
Strobe:  
LED Life:  
Dimensions:  
Please Note: Specifications and improvements in the design of this unit and this manual are  
subject to change without any prior written notice.  
©Elation Professional, Los Angeles Ca.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Elation Professional  
6122 S. Eastern Ave.  
Los Angeles, CA. 90040  
323-582-3322 / 323-832-9142 fax  
Rev. 09/15/2008 - visage  
Download from Www.Somanuals.com. All Manuals Search And Download.  

EAW Speaker System Weather Protected Loudspeaker System User Manual
Eiki Home Safety Product A 3 User Manual
Fujitsu Flat Panel Television P42HCA10 User Manual
Fundex Games Games Timber Tumble User Manual
Gateway Laptop p 79 User Manual
GE Clothes Dryer WBVH5200J User Manual
Geemarc Telephone CL400 User Manual
GE Intercom System 25413 User Manual
GE Microwave Oven Over the Range Microwave Oven User Manual
GE Washer GBSR1080 User Manual