1. General Information  
INTRODUCTION: Congratulations, you have just purchased one of the most innovative and  
reliable lighting fixtures on the market today! The Design Par 575H,™ has been designed to  
perform reliably for years when the guidelines in this booklet are followed. Please read and  
understand the instructions in this manual carefully and thoroughly before attempting to  
operate this unit. These instructions contain important information regarding safety during  
use and maintenance.  
UNPACKING: Thank you for purchasing the Design Par 575H™ by Elation Professional®.  
Every Design Par 575H™ has been thoroughly tested and has been shipped in perfect  
operating condition. Carefully check the shipping carton for damage that may have  
occurred during shipping. If the carton appears to be damaged, carefully inspect your unit  
for damage and be sure all accessories necessary to operate the unit have arrived intact. In  
the event damage has been found or parts are missing, please contact our customer  
support team for further instructions. Please do not return this unit to your dealer without  
first contacting customer support at the number listed below.  
CUSTOMER SUPPORT: Elation Professional® provides a customer support line, to provide  
set up help and to answer any question should you encounter problems during your set up  
comments or suggestions. For service related issue please contact Elation Professional®.  
Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m. Pacific Standard Time.  
Voice:  
Fax:  
(323) 582-3322  
(323) 582-3108  
E-mail:  
Forum:  
Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to  
rain or moisture.  
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs  
©Elation Professional®  
3
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
yourself, doing so will void your manufactures warranty.  
Please do not discard the shipping carton in the trash. Please recycle whenever possible.  
WARRANTY REGISTRATION: The Design Par 575H™ carries a two year (730 days)  
limited warranty. Please fill out the enclosed warranty card to validate your purchase. All  
returned service items whether under warranty or not, must be freight pre-paid and  
accompany a return authorization (R.A.) number. The R.A. number must be clearly written  
on the outside of the return package. A brief description of the problem as well as the R.A.  
number must also be written down on a piece of paper and included in the shipping  
container. If the unit is under warranty, you must provide a copy of your proof of purchase  
invoice. Items returned without a R.A. number clearly marked on the outside of the package  
will be refused and returned at customer’s expense. You may obtain a R.A. number by  
contacting customer support at (323) 582-3322.  
HALOGEN LAMP WARNING: This fixture is fitted with a halogen lamp,  
which is highly susceptible to damage if improperly handled. Never  
touch the lamp with your bare hands, as the oil from your hands will  
shorten lamp life. Also, never move the fixture until the lamps have had  
ample time to cool. Remember, lamps are not covered under warranty  
conditions.  
Epileptic Warning: Those suffering from epilepsy should avoid looking directly into the  
lamp at all times.  
Avoid switching the fixture on and off repeatedly in short intervals, as this will reduce lamp  
life and intensity.  
Never open this fixture while in use!  
During the initial operation of this fixture, a light smoke or smell may emit from the interior of  
the fixture. This is a normal process and is caused by excess paint in the interior of the  
casing burning off from the heat associated with the lamp and will decrease gradually over  
time.  
©Elation Professional®  
4
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
This device falls under protection-class 1. Therefore it is essential that the device be  
grounded properly.  
All electrical connections must performed by qualified personal.  
Be sure the available voltage matches the voltage requirements of the unit.  
Be sure the power cord is never crimped or damaged. If the power cord is damaged,  
replace it immediately with a new one of similar power rating.  
Always disconnect from main power before performing any type of service or any cleaning  
procedure.  
Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion  
of the cord.  
Please be aware that damages caused by modifications to the device are not subject  
to warranty.  
©Elation Professional®  
5
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
2. SAFETY INSTRUCTIONS  
The Design Par 575H™ is an extremely sophisticated piece of  
electronic equipment. To guarantee a smooth operation, it is  
important to follow the guidelines in this manual. The  
manufacturer of this device will not accept responsibility for  
damages resulting from the misuse of this fixture due to the  
disregard of the information printed in this manual.  
1. Always be sure that the fan and the air inlets remain clean and are never blocked.  
Allow about 6” (15cm) between this fixture and other devices or a wall to allow for  
proper cooling.  
2. Never touch the fixture during normal operation. This can cause severe personal  
injuries and/or damage to the fixture.  
3. Be sure to unplug the DESIGN PAR 575H™ from the power outlet before  
performing any service related issues.  
4. Lamp Replacement; Allow at least 30 minutes after disconnecting main power  
before you open the DESIGN PAR 575H™. To prevent personal injury, never  
touch the lamp if you are not absolutely sure it has cooled.  
5. Never look directly into the lamp beam. You risk injury to your retina, which may  
induce blindness.  
6. Be sure to track and record the lamp running time. The lamp should be changed  
at the end of the specified lamp life, regardless of lamp output. You may also have  
to change the lamp if it shows any deformations or damage. The same is with all  
glass components, color filters, lenses and mirrors.  
7. For safe operation, follow the Installation guide described in chapter two of this  
manual. Operating the DESIGN PAR 575H™ without suited safety aids such as  
safety cables or clamps can increase the risk of damage and/or personal injury.  
8. Installation should only be performed by qualified and certified personal.  
9. When mounting this fixture, use only the original rigging parts included with this  
fixture. Any structural modification will void the original manufactures warranty and  
©Elation Professional®  
6
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
may increase the risk of damage and/or personal injury.  
10. To reduce the risk of fire or shock, do not expose this fixture to rain or moisture.  
11. Do not attempt to operate this fixture if the power cord has become damaged or  
frayed.  
Important Notice: Damages resulting from the disregard of safety and general user  
instructions found in this user manual are not subject to any warranty claims.  
Never touch the device during operation!  
The housing may heat up  
Never look directly into the light source,  
as sensitive persons may suffer an epileptic shock.  
©Elation Professional®  
7
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
3. FEATURES  
Pan 630° or 540˚ (User selectable) / Tilt 265°  
3 operation mode: DMX controlled, stand alone or sound activated  
Strobe effect: 0~13 flashes per second or random strobe  
Dimmer intensity from 0%~100%  
User Selectable Power Supply (Internal)  
Control board with 4-digit display and foil-keyboard  
Digital display can be turned 180° to fit different installation position  
RDMX (Remote DMX addressing from any DMX console)  
Auto test for all functions  
Automatic Pan/Tilt Correction  
Glass Dichroic Reflector for Even Lamp Output  
Anti-Reflective Coated Lenses  
Gel frame holder included  
Uses 8 DMX channels (16bit mode)  
Several lamp options:  
o GLA  
o GLC  
o HX-400  
o HX-401  
o HX-600  
o HX-601  
USITT DMX-512 Complaint  
Value of each DMX-channel can be displayed  
8 User Assignable Program Presets - Internal Program: Edit and save programs to  
the incorporated EEPROM through the front control panel or external controller; you  
can save a maximum of 48 scenes, and run the saved programs by using the “run”  
menu on the front control panel  
©Elation Professional®  
8
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
4. GENERAL GUIDELINES  
This fixture is a professional lighting effect designed for use on stage, in nightclubs, in  
theatres, etc. Do not attempt operation or installation without a proper knowledge on how to  
so.  
This fixture was designed for indoor use only.  
Consistent operational breaks may ensure that the fixture will function properly for many  
years to come.  
Do not shake the fixture around. Avoid brute force when installing or operating the device.  
While choosing an installation location, please be sure that the fixture will not be exposed to  
extreme heat, moisture or dust. The minimum distance between the fixture and a wall or flat  
surface should be at least .5 meter (about 1.5ft).  
Always install the fixture with an appropriate safety cable. When installing the fixture in a  
suspended environment always be to use mounting hardware no less than M10 x 25 mm,  
also be sure the hardware is insert in the pre-arranged screw holes in the base of the  
fixture.  
When using the quick release “Omega” cam-lock system, be sure the four quick lock  
fasteners are locked in the quick lock holes correctly, see page 16 for more information on  
the proper mounting procedures.  
Do not attempt to operate this fixture until you have familiarized yourself with its functions.  
Do not permit operation by persons not qualified for operating this type of theatrical fixture;  
most damages are the result of operation by person unfamiliar with the operation of this  
type of fixture.  
If service is ever required, please use the original packaging to transport the fixture in for  
service.  
©Elation Professional®  
9
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
5. FIXTURE OVERVIEW  
1) HEAD ASSEMBLY – This assembly holds the lamp, gel holder, lens, and reflector.  
2) LAMP SOCKET ASSEMBLY COVER – This cover retains the lamp socket  
©Elation Professional®  
10  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
assembly. Remove this cover to access the lamp. Refer to page 13 for proper lamp  
replacement.  
3) ARM ASSEMBLY – This assembly holds the electronics, motors, and belt that  
control the unit’s tilt movement.  
4) MENU DISPLAY – Four segment LED menu display, details all menu functions. See  
page 25 for more information on the menu’s functions.  
5) MODE/ESC BUTTON – This button is used to access and exit the fixture’s on-board  
menu system.  
6) UP BUTTON – This button is used to scroll forward when navigating through the  
fixture’s menu system.  
7) DOWN BUTTON – This button is used to scroll backwards when navigating through  
the fixture’s menu system.  
8) ENTER BUTTON – This button is used to select and confirm a menu function.  
9) DATA PORT – This port is reserved for possible future updates to the fixture, but  
has no function as of yet.  
10) CARRYING HANDLE – This fixture contains a build-in carrying handle be sure to  
always transport this fixture by the handle and never by grasping the head or yoke  
assembly.  
11) POWER CORD – This cable provides main power to your fixture. Always be sure to  
use a properly grounded power cable. If this cable ever becomes frayed or damaged  
this cable should be replaced immediately by a qualified technician.  
12) FUSE HOLDER – This housing holds a 7A/250v GMA fuse and is designed to  
©Elation Professional®  
11  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
protect the electronics in the event of severer power fluctuations. Never defeat this  
fuse. In the event of fuse failure, always be sure to replace with an exact match fuse  
unless other wise specified by an authorized Elation Professional technician.  
13) DMX OUT JACK – This 3-pin XLR jack sends a DMX signal to another DMX fixture.  
For best results this jack should be terminated if it is the last fixture in a DMX daisy  
chain (see DMX termination on page 21).  
14) DMX IN JACK – This 3-pin XLR jack is receives an incoming DMX signal from a  
DMX controller.  
15) OMEGA CLAMP SOCKET – This fixture uses a cam-lock clamp system that allows  
a quick and efficient means to secure a clamp to the unit. To attach a clamp to the  
unit, attach a clamp that is rated to handle the weight of the unit to your omega  
clamp. After a clamp has been attached to the omega clamp, attach the cam locks  
to the designated position on the bottom of your unit. Lock the cam locks into  
position by turning the wing nuts 90°. See page 18 for proper clamp mounting and  
assembly.  
16) SAFETY CABLE RIGGING POINT – The fixture provides a built-in rigging point for  
a safety cable on the underside of the fixture, be sure to use this point and never  
secure a safety cable to a carrying handle.  
17) BASE COOLING FAN – This fan is used to cool the internal temperature of the  
base electronics.  
©Elation Professional®  
12  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
6. LAMP INSTALLATION INSTRUCTIONS  
Installing or replacing the lamp  
Only install the lamp with the device unplugged from the mains.  
The lamp has to be replaced when it is damaged or deformed.  
Before replacing the lamp be sure the unit has ample time to cool, to avoid injury to yourself  
never touch the lamp when it is hot.  
During the installation of halogen lamps do not touch the glass portion of the bulb bare  
handed. Always use a cloth to handle the lamps during insertion and removal.  
Do not install lamps with a higher wattage than that specified by the manufacture, they  
generate higher temperatures than which the device is designed to cool and may explode.  
Installation Procedure:  
1. Set the fixture on its’ base and remove the large retaining thumb screw.  
2. Gently pull out the lamp/socket assembly to access the lamp.  
3. Gently remove the old lamp by grasping it by the ceramic base.  
©Elation Professional®  
13  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
4. Carefully insert the new lamp into the socket (Be sure to only use an approved  
lamp). Please remember the lamp should fit completely in the lamp socket.  
5. Once the lamp has been inserted into the socket, gently slide the socket assembly  
back into place and secure with the large retaining thumbscrew.  
6. Always be sure to optimize the lamp after lamp replacement.  
Do not operate this device with open cover  
Lamp Optimization  
The lamp orientation and optimization must be adjusted after every lamp change. This  
procedure centers the lamp in the reflector. Proper optimization will increase lamp life and  
ensure a bright crisp output. Improper optimization may add a yellow tint to the lamp output  
and reduce intensity. The minimum deviation amount is 1.0mm. Running the fixture within a  
lower deviation can cause damage to the lamp and/or lens.  
The Design Par 575H™ lamp holder is aligned at the factory. However, due to slight  
imperfections in all lamps, fine adjustments will improve light performance. Please follow  
the procedure below for proper lamp optimization:  
1. Using either a DMX controller or the control panel on the unit (see “SPOT” in the  
fixture menu on page 26), strike the lamp and focus the light on a flat surface (beam  
open, white, no gobo, no effect).  
2. Center the hot-spot (the brightest part of the beam) using the 3 adjustment screws  
labeled 1, 2, and 3 as illustrated on the next page. Turn one screw at a time to drag  
the hot-spot diagonally across the projected image. If you cannot detect a hot-spot,  
adjust the lamp until the light is even.  
3. To reduce a hot-spot, pull the lamp in by turning all three screws clockwise a 1/4-turn  
©Elation Professional®  
14  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
at a time until the light is evenly distributed.  
4. If the light is brighter around the edge than it is in the center, or if light output is low,  
the lamp is too far back in the reflector. "Push” the lamp out by turning each of the  
adjustment screws ("1, 2, 3”) counterclockwise turn until the light is bright and  
evenly distributed.  
©Elation Professional®  
15  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
7. MOUNTING AND INSTALLATION  
Cautions:  
For added protection mount the fixtures in areas outside walking paths, seating areas, or in  
areas were the fixture might be reached by unauthorized personal.  
Before mounting the fixture to any surface, make sure that the installation area can hold a  
minimum point load of 10 times the device’s weight.  
Fixture installation must always be secured with a secondary safety attachment, such as an  
appropriate safety cable.  
Never stand directly below the device when mounting, removing, or servicing the fixture.  
Before taking into operation for the first time,  
the installation has to be approved by an expert.  
When installing the device, make sure there is no highly  
inflammable material within a distance of min. 0,5m  
Mounting  
The DESIGN PAR 575H™ is fully operational in two different mounting positions, hanging  
upside-down from a ceiling, or set on a flat level surface (see illustration below). Be sure  
this fixture is kept at least 0.5m away from any flammable materials (decoration etc.).  
Always use and install the supplied safety cable as a safety measure to prevent accidental  
damage and/or injury in the event the clamp fails.  
Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE0711-217  
for proper installation in Europe To ensure proper installation, only  
qualified staff should attempt installation.  
©Elation Professional®  
16  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
Mounting points  
Overhead mounting requires extensive experience, including amongst others calculating  
working load limits, a fine knowledge of the installation material being used, and periodic  
safety inspection of all installation material and the fixture. If you lack these qualifications,  
do not attempt the installation yourself. Improper installation can result in bodily injury.  
CAUTION!  
Be sure all electrical connections are performed by a qualified  
electrician.  
©Elation Professional®  
17  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
Be sure to complete all rigging and installation procedures before connecting the main  
power cord to the appropriate wall outlet.  
Clamp Mounting  
The Design Par 575H™ provides a unique mounting bracket assembly that integrates the  
hanging yoke as well as the safety cable rigging point in one unit (see the illustration  
below). When mounting this fixture to truss be sure to secure an appropriately rated clamp  
to the hanging yoke using a M10 screw fitted through the center hole of the hanging yoke.  
As an added safety measure be sure to attached at least one properly rated safety cable to  
the fixture using on of the safety cable rigging point integrated in the bracket assembly  
3
©Elation Professional®  
18  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
Securing the DESIGN PAR 575H™  
Regardless of the rigging option you choose for your DESIGN PAR 575H™ always be sure  
to secure your fixture with a safety cable. The fixture provides a built-in rigging point for a  
safety cable on the hanging bracket as illustrated above. Be sure to only use the  
designated rigging point for the safety cable and never secure a safety cable to a carrying  
handle.  
©Elation Professional®  
19  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
8. UNDERSTANDING DMX  
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation):  
Your fixture and your DMX controller require a standard 3-pin XLR connector for data input  
and data output (see figure below). If you are constructing your own cables be sure to use  
two conductor shielded digital cable rated at a 120 ohms (this cable can be purchased at  
almost all professional sound and lighting stores). Your cables should be made with a male  
and female 3-pin XLR connector on either end of the cable.  
Be sure to follow the above figure when making your own cables. Do not use the ground lug  
on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or  
allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the  
shield could cause a short circuit and erratic behavior.  
©Elation Professional®  
20  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
DMX-512 control connection  
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the  
other side to the male 3-pin XLR input of the moving head (Please refer to the diagram  
below.). You can chain multiple moving heads together through serial linking. The cable  
needed should be two conductor, shielded cable with XLR input and output connectors that  
is specially designed for DMX data transmission. Always be sure to daisy chain your in and  
out data connections, never split or “Y” your DMX connections unless you are using an  
approved DMX splitter such as the Elation Opto Branch 4™ or DMX Branch/4™.  
DMX-512 connection with DMX terminator  
You should always use a terminator on the last fixture to avoid erratic behavior. A terminator  
is a 90-120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR  
connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of the  
last fixture in your daisy chain to terminate the line. Using a cable terminator (Elation part  
number Z-DMX/T) will decrease the possibilities of erratic behavior.  
5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA  
transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX  
line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must  
be used, these adaptors are readily available fro Elation and most professional lighting  
retail stores. The following chart details a proper cable conversion.  
©Elation Professional®  
21  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
Fixture DMX addressing;  
All fixtures should be given a DMX starting address when using a DMX controller, so the  
correct fixture responds to the correct control signal. This digital starting address is the  
channel number from which the fixture starts to “listen” to the digital control information sent  
out from the DMX controller. The allocation of this starting DMX address is achieved by  
setting the correct DMX address on the digital display located on the head of the fixture.  
You can set the same starting address for all fixtures or a group of fixtures, or set different  
address for each individual fixture. Be advised that setting all you fixtures to the same DMX  
address will subsequently control all fixtures in the same fashion, in other words, changing  
the settings of one channel will affect all the fixtures simultaneously.  
If you set each fixture to a different DMX address, each unit will start to “listen” to the  
channel number you have set, based on the quantity of control channels (DMX channels) of  
each fixture. That means changing the settings of one channel will only affect the selected  
fixture.  
In the case of the Design Par 575H™, which is a 8 channel fixture, you should set the  
starting DMX address of the first unit to 1, the second unit to 9 (8 + 1), the third unit to 17 (8  
+ 9), and so on.  
Note: During start-up the Design Par 575H™ will automatically detect whether a DMX data  
signal is being received or not. If DMX data signal is being received, the display will show  
©Elation Professional®  
22  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
"A.XXX" (XXX representing the actual DMX address). If the fixture is not receiving a DMX  
signal the display will flash "A.XXX" (XXX representing the actual DMX address).  
If your fixture is connected to a DMX controller and the display is flashing (not receiving a  
DMX signal), please check the following:  
-
The 3 PIN XLR plug (cable with DMX signal from controller) is not connected or is  
not inserted completely into the DMX input jack.  
-
-
-
The DMX controller is switched off or defective.  
The DMX cable or connector is defective.  
A DMX terminator has been inserted into the last fixture in your DMX chain.  
©Elation Professional®  
23  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
9. DISPLAY LED INDICATORS.  
The Design Par 575H™ has two LED indicators on the display. These indicators are  
designed to give a quick visual indication of the fixtures’ status. The illustration below  
details the functionality of the LED indicators.  
. .  
.
.
DMX OK  
NO DMX  
DMX OK  
Lamp off  
NO DMX  
Lamp off  
Lamp on  
Lamp on  
The first LED indicators represents DMX signal:  
• If the indicators is on a clean DMX signal is present  
• If the indicator is off there is no DMX signal present  
The second LED indicator represents lamp condition:  
• If the indicator is on the lamp is struck and in working condition  
• If the LED indicator is off the lamp has not struck, has been turned off, or is bad.  
©Elation Professional®  
24  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
10. FIXTURE MENU  
On-Board System Menu: The DESIGN PAR 575H™ comes with an easy to navigate  
system menu. This next section will detail the functions of each command in the system  
menu.  
LED Control Panel: The control panel located on the top, front of the fixture allows you to  
access the main menu and make all necessary adjustments to the Design Par 575H™.  
During normal operation, tapping the “MODE/ESC” key once will access the fixture’s main  
menu. Once in the main menu you can navigate through the different functions and access  
the sub-menus with the Up and Down buttons. Once you reach a field that requires  
adjusting, tap the ENTER button to activate that field and use the UP and Down button to  
adjust the field. Tapping the Enter button once more will confirm your setting. Once a  
setting is saved the LED will briefly readout PASS to confirm a new setting has been made  
and locked into memory. You may exit the main menu at any time without making any  
adjustments by tapping the MODE/ESC button.  
MODE/ESC Button - To access the main menu locate the MODE/ESC button on the front  
of the unit. Press this button to activate the system menu. Tap the UP button until you reach  
the function you wish to change. When you reach the function you wish to change tap the  
ENTER button once to select that menu function. When a function is selected the menu will  
begin to flash, use the UP or DOWN button to change the function. Once your changes are  
made tap the ENTER button yet again to lock the change in the system menu. To exit  
without making any changes tap the MODE/ESC button.  
Default settings shaded.  
Indicate the staring DMX address  
0
1
ADDR  
TEST  
AXXX A001  
T-01~T-XX  
RUN  
A001 also is the setting for slave  
Automatically test the function  
Runs fixture as “master” or “alone”  
for auto  
MSTR/ALON  
Runs fixture as “master” or “alone”  
for audio  
2
PLAY  
AUDI  
MSTR/ALON  
AUTO  
OFF / RUN /AUDI  
Runs fixture for no DMX  
©Elation Professional®  
25  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
Manually switches lamp “on” and  
“off”  
Reset all motors and returns fixture  
to home  
3
4
LAMP  
RESE  
ON/OFF  
ALL  
SCAN  
LIFE  
Reset only motors for pan/tilt  
Displays the total fixture running  
time  
0000~9999  
0000~9999  
5
TIME  
LAMP  
Displays a lamps running time  
CLMP  
Clear lamp running time  
Reverses the pan movements  
Reverses the tilt movements  
Switch between 16 bit/8 bit  
Pan degree select  
6
7
8
9
RPAN  
RTLT  
FINE  
ON/OFF  
ON/OFF  
ON/OFF  
630/540  
M-XX M-70  
DEGR  
10 MIC  
Mic sensitivity  
Display the DMX512 value of each  
channel  
Display turn off after 2mins  
This function will reverse the display  
180  
VALU  
D ON  
FLIP  
D–XX D-00 (DXXX)  
ON/OFF  
11 DISP  
ON/OFF  
LAAU  
RDMX  
ON/OFF  
Automatic lamp start with power  
Change DMX address via external  
controller  
ON/OFF  
DLOF  
DLAY  
SPOT  
ON/OFF  
D–XX D-05  
ON/OFF  
Switch lamp via DMX  
Lamp on delay time  
Lamp optimization  
Resets all the fixture functions to  
default  
Pan/tilt feedback (error correction)  
on/off  
DFSE  
FEED  
ON/OFF  
ON/OFF  
12 SPEC  
FANS  
VER  
N.A  
V1.0~V9.9  
No Apply  
Software version  
Fixture code *code is  
“C050”  
CH01~CH30 XXXX(-128~127) Motor Calibration  
CODE  
CXXX  
ADJU  
STEP  
Set the amount of your  
program  
0 1 XX(00~FFH) Edit the channels of each  
3 0 XX(00~FFH) scene  
T XXX(001~999) Time for each scene  
S–01 ~S–48  
C–01~C–30  
13 EDIT  
SCXX  
TIME  
CEDT  
RE.XX  
ON/OFF  
ON/OFF  
Edit program via controller  
Auto Save  
Program test  
REC.  
RUN  
©Elation Professional®  
26  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
Main Menu Functions  
1. ADDRESS MENU  
- AOO1 - A511 (Value) - This is where you set the fixtures DMX address.  
Setting/Changing the DMX Address  
After applying power to the DESIGN PAR 575H™ the LED will display the fixture’s  
current DMX address immediately after the reset sequence. If the fixture is not  
receiving a DMX signal the display will flash continuously. To set or adjust a DMX  
address, please follow the procedure below:  
1. Switch on the DESIGN PAR 575H™ and wait for the fixture reset process to  
finished.  
2. Press the Mode/Esc button to access the main menu. Toggle through the menu by  
pressing the Up and Down buttons until the display shows A001. Tap the enter  
button to make changes to the address, the current three digit address will  
immediately begin to flash.  
3. While the current three-digit address is flashing, use the Up and Down buttons to  
select adjust the address. Lock your new address into the unit’s memory by  
pressing the Enter button. After the new address has been successfully stored into  
the fixture’s memory the LED will briefly readout PASS.  
The DMX address is non-destructible and will remain in the fixture’s memory even when  
power to the fixture has been switched off. Memory is backed-up and retained by an  
internal power source with a five year shelf life.  
2. TEST MENU  
- T-01 - T-XX (Test) - Tests the functions of each channel. There are 16 DMX  
channels, and all except channels 7, 11, and 15 can be tested. To enter the test menu  
follow the procedure below:  
1. Access the main menu.  
2. Tap the UP button until “TEST” is displayed, press ENTER.  
3. The display will show T-01. You can now press the up button and test the different  
channels. For example: If you press the up button until “T-03” is displayed, the unit  
©Elation Professional®  
27  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
will test the color channel, changing the color one by one and show the rainbow  
effect with different speeds. Again please remember, there are 8 DMX channels,  
and all can be tested  
4. Press MODE/ENTER or EXIT to exit.  
3. PLAY MENU -  
RUN  
This feature is used to run the internal preset programs in either a Master/Slave  
or a stand-alone operating mode. Follow the procedure below to enter the run menu:  
1. Access the main menu.  
2. Tap the UP or DOWN button until “PLAY” is displayed, press ENTER.  
3. Tap the UP or DOWN button until “RUN” is displayed, press ENTER.  
4. Tap the UP or DOWN button to select either “Master” or “Alone” and press ENTER.  
5. Press MODE/ESC to return to the main menu.  
AUDI  
- This feature is used to run the internal preset programs in AUDIO mode in either  
a Master/Slave or a stand-alone operating mode Follow the procedure below to enter the  
audio menu:  
1. Access the main menu.  
2. Tap the UP or DOWN button until “PLAY” is displayed, press ENTER.  
3. Tap the UP or DOWN button until “AUDI” is displayed, press ENTER.  
4. Tap the UP or DOWN button to select either “Master” or “Alone” and press ENTER.  
5. Press MODE/ESC to return to the main menu.  
AUTO  
– Runs the unit without any DMX signal in stand-alone mode. Follow the procedure  
below to enter the auto menu:  
1. Access the main menu.  
2. Tap the UP or DOWN button until “PLAY” is displayed, press ENTER.  
3. Tap the UP or DOWN button until “AUTO” is displayed, press ENTER.  
4. Tap the UP or DOWN button to select “OFF”, “RUN” or “AUDI” and press ENTER to  
©Elation Professional®  
28  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
confirm.  
5. Press MODE/ESC to return to the main menu.  
4. LAMP MENU -  
– This menu function will manually turn the lamp on and off. Follow the procedure  
below to enter the lamp menu:  
1. Access the main menu.  
2. Tap the UP button until “LAMP” is displayed, press ENTER.  
3. The display will show “ON/OFF”.  
4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate  
this function.  
5. Press ENTER to confirm.  
6. Press MODE/ESC to return to the main menu.  
5. RESE (RESET) MENU -  
ALL - Resets all the motors in the unit.  
SCAN - Resets the Pan and Tilt motors.  
ALL  
- When you activate this reset function, the fixture will begin to reset all motors.  
1. Access the main menu.  
2. Tap the UP button until “RESE” is displayed, press ENTER.  
3. Tap the UP button until “ALL” is displayed, press ENTER.  
4. The display will show “ON/OFF”. Press the UP button to select “ON” to reset the  
color motor.  
5. Press ENTER to confirm  
6. Press MODE/ESC to return to the main menu.  
SCAN  
- When you activate this reset function, the fixture will only reset the Pan and  
Tilt mirror motor.  
©Elation Professional®  
29  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
1. Access the main menu.  
2. Tap the UP button until “RESE” is displayed, press ENTER.  
3. Tap the UP button until “SCAN” is displayed, then press ENTER to confirm.  
4. The display will show “ON/OFF”. Press the UP button to select “ON” to reset the  
color motor. Press ENTER to confirm.  
5. Press MODE/ESC to return to the main menu.  
6. TIME MENU -  
LIFE - Displays the fixtures total running time.  
LAMP - Displays the lamp running time.  
CLMP - Clears the lamp running time.  
LIFE  
- With this function you can display the total running time of the fixture.  
1. Access the main menu.  
2. Tap the UP button until ”TIME” is displayed, press ENTER.  
3. Tap the UP button until “LIFE” is displayed, press ENTER.  
4. Press MODE/ESC to return to the main menu.  
LAMP  
- With this function you can display the running time of the lamp.  
1. Access the main menu.  
2. Tap the UP button until ”TIME” is displayed, press ENTER.  
3. Tap the UP button until “LAMP” is displayed, press ENTER.  
4. Press MODE/ESC to return to the main menu.  
CLMP  
- With this function you can clear the running time of the lamp. Note: Please  
clear the lamp time every time you replace the lamp.  
1. Access the main menu.  
©Elation Professional®  
30  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
2. Tap the UP button until “TIME” is displayed, press ENTER.  
3. Tap the UP button until “CLMP” is displayed, press ENTER.  
4. Press MODE/ ENTER, the display will show “ON/OFF”.  
5. Press the UP button to select “ON” to activate this function, or “OFF” to  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
7. RPAN MENU  
- This menu function will reverse the mirror PAN movements.  
1. Access the main menu.  
2. Tap the UP button until “RPAN” is displayed, press ENTER.  
3. The display will show “ON/OFF”.  
4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate  
this function.  
5. Press ENTER to confirm.  
6. Press MODE/ESC to return to the main menu.  
8. RTLT MENU  
- This menu function will reverse the mirror TILT movements.  
1. Access the main menu.  
2. Tap the UP button until “RTLT” is displayed, press ENTER.  
3. The display will show “ON/OFF”.  
4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate  
this function.  
5. Press ENTER to confirm.  
6. Press MODE/ESC to return to the main menu.  
9. FINE MENU  
- This menu item switches between 16 bit (fine) and 8 bit (coarse) modes. When  
this function is turned on the fixture will operate in 16 bit (fine) mode. When functioning in  
16 bit mode the fixture will use 8 DMX channels, when the 16bit function is turned off the  
©Elation Professional®  
31  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
fixture will use 6 DMX channels. To access the Fine menu follow the procedure below:  
1. Access the main menu.  
2. Tap the UP button until “FINE” is displayed, press ENTER.  
3. The display will show “ON/OFF”.  
4. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate  
this function.  
5. Press ENTER to confirm.  
6. Press MODE/ESC to return to the main menu.  
10. DEGR MENU -  
- This menu function will toggle between the 630°and 540°for pan movement  
When this function is turned on, the fixture will operate with a pan movement of 630˚.  
1. Access the main menu.  
2. Tap the UP button until “DEGR” is displayed, press ENTER.  
3. The display will display “630/540”.  
4. Press the UP button to select 630˚ or 540˚ for the pan movement angle  
5. Press ENTER to confirm.  
6. Press MODE/ESC to return to the main menu.  
11. MIC MENU  
- This function allows for electronic control of the internal microphone’s sound  
sensitivity.  
1. Access the main menu.  
2. Tap the UP button until “MIC” is displayed and press ENTER.  
3. The display will show “M-XX” (Where XX represents a value between 00 & 99).  
4. Use the UP and DOWN button to adjust the mic sensitivity, 99 being the highest.  
5. Press ENTER to confirm and lock your new setting in place.  
6. Press MODE/ESC to return to the main menu.  
12. DISPLAY MENU  
- This menu function will control the various on-board display features.  
©Elation Professional®  
32  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
VALU – This function will display the DMX value of each channel as it is  
adjusted through the use of a DMX console.  
1. Access the main menu.  
2. Tap the UP button until “DISP” is displayed.  
3. Press ENTER, the display will show “VALU”.  
4. Press ENTER, once again “d-00” will be displayed.  
5. Press ENTER to confirm.  
6. Press MODE/ESC to return to the main menu.  
D ON – This function will turn the display off after the has gone two seconds  
without any menu activity.  
1. Access the main menu.  
2. Tap the UP button until “DISP” is displayed.  
3. Press ENTER, the display will show “VALU”.  
4. Tap the UP button until ”D-ON” is displayed and tap the ENTER button.  
5. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate  
this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
FLIP – This function will reverse the display readout buy 180˚.  
1. Access the main menu.  
2. Tap the UP button until “DISP” is displayed.  
3. Press ENTER, the display will show “VALU”.  
4. Tap the UP button until ”FLIP” is displayed and tap the ENTER button.  
5. Press the UP button to select “ON” to activate this function, or “OFF” to deactivate  
this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
13. SPEC MENU – This menu option access all the special functions listed below.  
LAAU - Automatic lamp start with power.  
©Elation Professional®  
33  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
RDMX - Allows DMX address to be changed via and external DMX controller.  
DLOF - Switch lamp off via DMX controller.  
DLAY - Lamp-on delay time.  
SPOT - This provides a spot beam for better lamp optimization.  
DFSE (Default) - Resets the unit to all default settings.  
FEED - This function turn the DMX correction feature “ON” (default) or “OFF.”  
FANS- Changes the functionality of the built-in fans.  
VER (Version) - Displays the software version.  
ADJU – Calibration functions  
LAAU  
– This function controls the automatic lamp start feature. By default the unit will  
automatically ignite the lamp when unit is turned on. Use this function to turn this  
feature on and off.  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “LAAU” is displayed, press ENTER.  
4. The display will show “ON/OFF.”  
5. Press  
the buUttPon  
to  
display  
“ON”  
toor actiOvaFtFe thtios  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
RDMX  
– This function allows the DMX address to remotely be adjusted from a DMX  
console. This setting requires special settings for both the controller and the fixture.  
RDMX is on by default. Follow the procedure listed below to access the RDMX  
functions:  
Fixture Settings:  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “RDMX” is displayed, press ENTER.  
©Elation Professional®  
34  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
4. The display will show “ON/OFF.”  
5. Press the UP button to display “ON” to activate this function, or “OFF” to  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
Controller Settings:  
1. Set the DMX value of channel 1 to a value of 7.  
2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7"  
you can adjust the starting address between 1 and 255. When set to "8" you can  
adjust the starting address between 256 and 511.  
3. Use channel 3 to set your desired DMX starting address. For example: If you  
want to set the starting address to 57, set channel 1 to a value of “7,” set channel  
2 to a value of “7” and use channel 3 to set your address to 57 by selecting a  
channel value of 57. Example 2: If you want to set the starting address to 420,  
set channel 1 to a value of “7,” channel 2 to "8" and channel 3 to "164"  
(256+164=420).  
4. Wait for approximately 20 seconds for the unit to complete the address  
reset function.  
DLOF  
– This feature allow you to control the lamp via DMX.  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “DLOF” is displayed, press ENTER.  
4. The display will show “ON/OFF.”  
5. Press the UP button to display “ON” to activate this function, or “OFF” to  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
DLAY  
©Elation Professional®  
35  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
– This function allows the user to set a lamp “strike” delay time.  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “DLAY” is displayed, press ENTER.  
4. The display will show “D-XX.”  
5. Press the UP and DOWN buttons to adjust the delay time.  
6. When completed press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
SPOT  
– This function allows you to optimize the lamp without the use of an external  
DMX controller. In this mode, the device will not react to any control signal.  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “DFSE” is displayed, press ENTER.  
4. The display will show “ON/OFF.”  
5. Press  
the buUttPon  
to  
display  
“ON”  
toor actiOvaFtFe” thtois  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
DFSE  
- With this function you can restore the factory default settings of the fixture. All  
settings will be set back to the default values. Any edited scenes will be lost. When  
restoring the factory settings the unit must be set to the address that the unit was in  
when you started editing. When you confirm this function, the fixture will begin to  
reload the original factory settings.  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “DFSE” is displayed, press ENTER.  
4. The display will show “ON/OFF.”  
©Elation Professional®  
36  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
5. Press the UP button to display “ON” to activate this function, or “OFF” to  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
FEED  
- Use this function to activate the pan/tilt error correction.  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “FEED” is displayed, press ENTER.  
4. The display will show “ON/OFF.”  
5. Press the UP button to display “ON” to activate this function, or “OFF” to  
deactivate this function.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
FANS  
- This function is used to change the functionality of the internal cooling fans.  
Follow the procedure below to access the fan menu:  
1. Access the main menu.  
2. Tap the UP or DOWN button until “SPEC” is displayed, press ENTER.  
3. Tap the UP or DOWN button until “FANS” is displayed, press ENTER.  
4. The display will show “HIGH/AUTO”.  
5. Press UP or DOWN button to select “HIGH” or “AUTO”.  
6. Press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
VER  
- Use this function to display the Software version of the unit.  
1. Access the main menu.  
2. Tap the UP button until “SPEC” is displayed, press ENTER.  
3. Tap the UP button until “VER” is displayed, press ENTER.  
©Elation Professional®  
37  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
4. The display will show “V-1.0,” the display may also show, “V-2.0,” “V-9.9” etc.  
5. Press ENTER or MODE/ESC to exit.  
ADJU  
- This function is used to calibrate the various internal motors in the event the  
internal homing mechanism become slightly out of adjustment. This function is  
protected with a password to prevent unauthorized personal from tampering with the  
fixture. To enter the calibration menu follow the steps below:  
1. Access the main menu.  
2. Tap the UP or DOWN buttons until “ADJU” is displayed, then press ENTER.  
3. Tap the UP or DOWN buttons until “CODE” is displayed, then press ENTER.  
4. The display will show “CXXX”, were as XXX represents the calibration  
password. The calibration password is “C050.” Use the UP or DOWN buttons to  
enter the proper password.  
5. Once the proper password is entered the display will read “CHXX”, were as  
“XX” represents the fixture channel number, in the case of the Design Par  
575H™ 1 ~ 16.  
6. Select the desired channel to be calibrated by pressing the UP or DOWN  
buttons and then ENTER to confirm.  
7. The display will then read “xxxx”, were “xxxx” stands for the calibrate values.  
8. Adjust the desired calibration value between –128 and 127 by pressing the UP  
and DOWN. As you scroll up and down through the calibration values you will  
notice slight changes in the wheel or motor you are attempting to calibrate.  
9. Once you reach your desired calibration press ENTER to confirm and lock in  
your calibration.  
14. EDIT MENU  
- This menu item allows you to write a program into the fixture’s internal memory  
(EEPROM) via the control panel or via an external DMX controller.  
STEP (S-01 - S-48) - These are the steps slots that you write your programs into. There  
are at total of 48 steps.  
©Elation Professional®  
38  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
STXX (SC01 – SC48) - These are the scenes that are stored in your program. There are a  
total of 48 scenes. C-01 - C-11 (Channel 1 - Channel 11) – Represents the total fixture  
channels for each scene that can be edited.  
TIME (Time) - Running time of the entire program.  
CEDT - Edit program using a external controller.  
REC – Auto save function.  
RUN – Program test mode.  
REC  
- Records scenes automatically from any external DMX controller and stores them  
inside the fixtures built-in memory. These scenes can then be recalled without the use  
of an external controller.  
1. Access the main menu.  
2. Tap the UP or DOWN buttons until “EDIT” is displayed, then press ENTER.  
3. Tap the UP or DOWN buttons until “REC” is displayed, then press ENTER.  
4. After entering the REC function the display will read “RE.XX,” where as “XX”  
represents the scene number in the internal memory to which the scene will be  
stored.  
5. Press the UP or DOWN buttons to select the desired scene number.  
6. When you reach the scene number you wish to store the scene to, press  
ENTER to confirm and lock the scene into the fixture’s memory.  
7. Press MODE/ESC to return to the main menu.  
STEP  
- With this function you can program the number of steps in your individual  
Program.  
1. Access the main menu.  
2. Tap the UP button until “EDIT” is displayed, press ENTER.  
3. Tap the UP button until “STEP” is displayed, press ENTER.  
4. The display shows “S-01,” this indicates the first step of your program. You can  
call up to 48 scenes in “Run.” For example; if “S-05” is displayed, it means that  
the scene will “RUN” the first 5 scenes you saved in “Edit.”  
©Elation Professional®  
39  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
5. Press ENTER to save and MODE/ESC to exit.  
SC01  
- This function allows you to choose the total number of scenes in your internal  
program.  
1. Access the main menu.  
2. Tap the UP button until “EDIT” is displayed, press ENTER.  
3. Tap the UP button until “SC01” is displayed.  
4. The display indicates “SC01,” this stands for the first scene of your program.  
You may recall up to 48 scenes. For example, if you choose “SC05,” and then  
select the “Run” function, the first 5 scenes you saved in “Edit” mode will run.  
5. Press ENTER to save and MODE/ESC to exit.  
Editing procedure 1: Using the control board only.  
1. Access the main menu.  
2. Tap the UP button until “EDIT” is displayed and press ENTER.  
3. The display will show “SC-01”, this stands for the scene number. For example,  
“SC-01” is displayed, it means you will be editing scene 1, press ENTER. You  
can change the scene number by tapping the UP button.  
4. Press ENTER, the display will show “C-01,” this represents the channel number.  
If “C-01is displayed, you will be editing the fixture’s channel 1 value of the  
selected scene, press ENTER. You can change the channel number by tapping  
the UP button.  
5. The display will show the DMX value for the channel that is being edited. It will  
be displayed as “11XX,” it stands for Channel 11 of the editing scene, the DMX  
value is “XX.”  
6. Adjust the DMX value by tapping the UP button, until you get the expected effect  
for this channel.  
7. Press ENTER to enter the editing of the other channels of the scene.  
8. Repeat steps 5-8, until you finish setting all the DMX values for all the channels  
of this scene, each scene can have 16 channels maximum.  
9. Once all the channels are completed, the display will begin to flash “TIME,” this  
©Elation Professional®  
40  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
indicates the time needed to run this scene.  
10.Press ENTER to edit the time needed, the display shows TXXX, XXX”  
represents the time needed to run this scene. For example, T002means  
scene 1 needs 0.4 seconds to run, T-15means this scene needs 3.0  
seconds to run. Note: “XXis always 0.2 seconds not one second.  
11.Adjust the time needed by tapping the UP button.  
12.Press ENTER to save the settings for the scene you are editing, the display will  
change to the next scene automatically.  
13.Repeat steps 3-12 to edit other scenes, you can edit and save 48 scenes  
maximum.  
14.Press MODE/ESC to exit and save your edited scene into the fixtures internal  
memory. The number of steps can be defined under “EDIT” and the scenes can  
be called up under “Run.” To run the scenes see page 30.  
Editing procedure 2: Using an external controller.  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
Call up the first scene in your controller now.  
Select “SC01” by pressing the UP or DOWN buttons.  
Press MODE/ESC, the display shows “SC01”.  
Press MODE/ESC, the display shows “C-01”.  
Select "CEDT" by pressing the UP or DOWN buttons.  
Press MODE/ESC, the display shows "OFF".  
Press UP, the display will read "ON".  
Press MODE/ESC, the display shows "SC02". You successfully downloaded  
the first scene.  
9.  
Adjust the Step-time as described above.  
10. Call up the second scene in your controller now.  
11. Repeat steps 5-11 until all desired scenes are downloaded.  
12. Press MODE/ESC to exit. The number of steps can be defined under “STEP”  
and the scenes can be called up under “RUN.”  
RUN  
- This function allows you to “RUN” the user-installed program. You can set the  
©Elation Professional®  
41  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
number of steps under Step (S-01- S-48). You can edit the individual scenes under Edit.  
1. Access the main menu.  
2. Tap the UP button until “EDIT” is displayed, press ENTER.  
3. Tap the UP button until “RUN” is displayed, press ENTER.  
4. “AUTO” is displayed. If you press the UP button it will show “SOUN”. Select  
which one you want to activate, and press ENTER.  
5. Press UP, to select “ALON” or “NAST”. Which mean stand alone, and  
master/slave mode.  
6. Select a mode, and press ENTER to confirm.  
7. Press MODE/ESC to return to the main menu.  
©Elation Professional®  
42  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
11. DMX CHANNEL TRAITS:  
The chart below details the channel layout for 8 DMX channels (default).  
In 8bit mode the “Pan Fine” and “Tilt Fine” channels are not used, thus converting the  
fixture into a 6-channel DMX fixture.  
CHANNEL 1: Pan Movement (max. 630° or 540˚ User Selectable)  
CHANNEL 2: 16bit Pan Movement (pan fine)  
CHANNEL 3: Tilt Movement (max. 265°)  
CHANNEL 4: 16bit Tilt Movement (tilt fine)  
CHANNEL 5: Speed Control (Pan/Tilt movement, blackout selection)  
CHANNEL 6: Dimmer Control  
CHANNEL 7: Strobe (0-13Hz), and Shutter close/open function + random strobe  
CHANNEL 8: Special (Auto program control + lamp on, motor reset, lamp switch off)  
©Elation Professional®  
43  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
DMX channel function and values:  
Channel 1 – Pan movement 8bit:  
Channel 2 – Pan fine (16bit only):  
Channel 3 – Tilt movement 8bit:  
Channel 4 – Tilt fine (16bit only):  
Channel 5 – Speed pan/tilt movement:  
0~255  
Max to min speed  
Channel 6 – Dimmer intensity:  
0~255  
Intensity 0% ~ 100%  
Channel 7 – Strobe:  
0~4  
Dimmer  
5~255  
Strobe effect from slow to fast  
Channel 8 – Lamp on/off, reset, internal programs:  
Normal control  
No function  
Lamp on  
0~19  
20~39  
40~59  
60~79  
Lamp switch off  
80~84  
85~87  
88~99  
All motor reset  
Scan motor reset  
No function  
100~119  
120~139  
140~159  
160~179  
180~199  
200~219  
220~239  
240~255  
Internal program 1  
Internal program 2  
Internal program 3  
Internal program 4  
Internal program 5  
Internal program 6  
Internal program 7  
Auto program by music  
©Elation Professional®  
44  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
12.ERROR CODES:  
When power is applied, the unit will automatically enter a “reset/test” mode. This mode  
brings all the internal motors to a home position. If there is an internal problem with one or  
more of the motors an error code will flash in the display in the form of “XXer” were as XX  
will represent a function number. For example, when the display shows “03Er,” there is  
some type of error with the tilt motor. If there are multiple errors during the start-up process  
they will all flash in the display. For example: if the fixtures has errors on channel 1, and  
channel 2, at the same time, you will see the error message “01Er”, and “03Er,” flash  
repeated 5 times.  
If an error does occur during the initial start-up procedure the fixture will self-generate a  
second reset signal and attempt to realign all the motors and correct the errors, if the error  
persist after a second attempt a third attempt will be made.  
If after a third attempt all the errors have not been corrected the fixture will make the  
following determinations: 1) 3 or more errors - The fixture cannot function properly with  
three or more errors therefore the fixture will place itself in a stand-by mode until  
subsequent repairs can be made. 2) Less than 3 errors - The fixture has less than 3 errors,  
therefore most other functions will work properly. The fixture will attempt to operate normally  
until the errors can be correct by a technician. The errors in question will remain flashing in  
the display as a reminder of internal errors.  
01Er – PAN movement error:  
The yoke is not located in the default position after start-up or after a reset command. This  
message will appear after a fixture reset if the pan-yoke’s magnetic-indexing circuit  
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure  
(defective motor or a defective motor IC drive on the main PCB).  
03Er – TILT movement error:  
The head is not located in the default tilt position after start-up or after a reset command.  
This message will appear after a fixture reset if the tilt magnetic-indexing circuit  
©Elation Professional®  
45  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure  
(defective motor or a defective motor IC drive on the main PCB).  
©Elation Professional®  
46  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
13. CLEANING AND MAINTENANCE  
The following points have to be considered during the inspection:  
1. Be sure all screws and fasteners are securely tightened at all times. Lose screws  
may fall out during normal operation resulting in damage or injury as larger parts  
could fall.  
2. There must not be any deformations on the housing, rigging hardware and rigging  
points (ceiling, suspension, trussing). Damaged rigging points or unsecured rigging  
could cause the unit to fall and serious injure a person.  
3. All mechanical parts and motors should not show any traces of serious wear and  
should rotate freely.  
4. Electric power supply cables must not show any damage, material fatigue or  
sediments. Never remove the ground prong from the power cable.  
Further instructions depending on installation and usage have to be adhered by a skilled  
installer and any safety problems should be addressed before attempting operation.  
Disconnect from mains before starting maintenance operation.  
We recommend frequent cleaning of the device. This will ensure operational longevity and  
crisp light output. When cleaning, please use a moist, lint-free cloth. Never use alcohol or  
solvents.  
There are no user serviceable parts inside this fixture with the exception of the lamp.  
Please refer all other service related issues to an authorized Elation service technician.  
Should you decide to service the fixture yourself please order genuine Elation parts directly  
from Elation.  
©Elation Professional®  
47  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
14. 2-YEAR LIMITED WARRANTY  
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional®  
products to be free of manufacturing defects in material and workmanship for a period of  
two years, (730 days) from the date of purchase. This warranty shall be valid only if the  
product is purchased within the United States of America, including possessions and  
territories. It is the owner’s responsibility to establish the date and place of purchase by  
acceptable evidence, at the time service is sought.  
B. For warranty service, send the product only to the Elation Professional® factory. All  
shipping charges must be pre-paid. If the requested repairs or service (including parts  
replacement) are within the terms of this warranty, Elation Professional® will pay return  
shipping charges only to a designated point within the United States. If the entire instrument  
is sent, it must be shipped in its original package. No accessories should be shipped with  
the product. If any accessories are shipped with the product, Elation Professional® shall  
have no liability what so ever for loss of or damage to any such accessories, nor for the  
safe return thereof.  
C. This warranty is void if the serial number has been altered or removed; if the product is  
modified in any manner which Elation Professional® concludes, after inspection, affects the  
reliability of the product; if the product has been repaired or serviced by anyone other than  
the Elation Professional® factory unless prior written authorization was issued to purchaser  
by Elation Professional®; if the product is damaged because not properly maintained as set  
forth in the instruction manual.  
D. This is not a service contract, and this warranty does not include maintenance, cleaning  
or periodic check-up. During the period specified above, Elation Professional® will replace  
defective parts at its expense, and will absorb all expenses for warranty service and repair  
labor by reason of defects in material or workmanship. The sole responsibility of Elation  
Professional® under this warranty shall be limited to the repair of the product, or  
replacement thereof, including parts, at the sole discretion of Elation Professional®. All  
products covered by this warranty were manufactured after January 1, 1990, and bare  
©Elation Professional®  
48  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
identifying marks to that effect.  
E. Elation Professional® reserves the right to make changes in design and/or improvements  
upon its products without any obligation to include these changes in any products  
theretofore manufactured.  
F. No warranty, whether expressed or implied, is given or made with respect to any  
accessory supplied with products described above. Except to the extent prohibited by  
applicable law, all implied warranties made by Elation Professional® in connection with this  
product, including warranties of merchantability or fitness, are limited in duration to the  
warranty period set forth above. And no warranties, whether expressed or implied, including  
warranties of merchantability or fitness, shall apply to this product after said period has  
expired. The consumer’s and or Dealer’s sole remedy shall be such repair or replacement  
as is expressly provided above; and under no circumstances shall Elation Professional® be  
liable for any loss or damage, direct or consequential, arising out of the use of, or inability to  
use, this product.  
G. This warranty is the only written warranty applicable to Elation Professional® Products  
and supersedes all prior warranties and written descriptions of warranty terms and  
conditions heretofore published.  
©Elation Professional®  
49  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
15. PHOTOMETRIC DATA:  
©Elation Professional®  
50  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
16. DIMENSIONAL DRAWINGS:  
©Elation Professional®  
51  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
17. Circuit Schematic  
©Elation Professional®  
52  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
18. TECHNICAL SPECIFICATIONS  
Power supply  
_98VAC, 50Hz;_120VAC, 50Hz;_208VAC, 50Hz;  
Power consumption  
_220VAC, 50Hz;_230VAC, 50Hz;_240VAC, 50Hz; or  
_98VAC,60Hz;_120VAC,60Hz;_208VAC,60Hz;  
_220VAC,60Hz;_230VAC,60Hz;_240VAC,60Hz;  
Fuse protection  
120V = 7A/250V, GMA (5x20mm fine-wire fuse)  
220V = 4A/250V, GMA (5x20mm fine-wire fuse)  
Lamp  
Options  
GLA, GLC, HX-601, HX-600, HX-401, HX-400  
Optical system  
Parabolic glass reflector  
Includes Medium Lens  
Lens Options: Very Narrow, Narrow, Medium, Wide  
Color  
Gel Frame Included  
Strobe / Dimmer  
Strobe-effect with variable speed 1 - 13 flashes per second  
Continuously electronic dimmer 0 - 100%  
DMX Channels  
8 (16bit – default) or 6 (8bit – user selectable)  
Drive  
Standard DMX-512, 3 pole XLR; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.  
Starting DMX [001].  
Pan / Tilt  
Pan- movement  
Tilt- movement  
Weights and measures  
Dimensions  
630° in max. 2.0 seconds, 16 bit resolution  
265° in max. 1.5 seconds, 16 bit resolution  
43cm (W) x 36.2cm (L) x 49.2cm (H) ~ Head vertical  
23Kgs / 51Lbs  
Weight (net)  
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.  
©Elation Professional®  
53  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
©Elation Professional®  
54  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
©Elation Professional®  
55  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Par 575H™  
Elation Professional  
4295 Charter Street  
Los Angeles, CA. 90058  
323-582-3322 / 323-582-3108 fax  
©Elation Professional®  
56  
Design Par 575H™  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Blower LEAF BLOWER User Manual
Electro Voice Microphone RE92TX User Manual
EVGA Computer Hardware 112 CK NF70 User Manual
Fedders Heat Pump CH18ABD1VF User Manual
Fisher Paykel Oven 447443 User Manual
Garland Convection Oven MCO GD 10E User Manual
Geemarc Conference Phone Jupiter 4 User Manual
Gefen Cable Box EXT DVI 2 MDP User Manual
GE GPS Receiver PSC23SHT User Manual
Gitzo Camcorder Accessories GT3530LSV User Manual