Elation Professional Network Router RMD 1220 User Manual

User Instructions  
RMD-1220  
Rack Mount Dimmer-12Channel  
It is important to read this instruction book prior to installing or using your new  
24-004-2355-00  
Rev1.0  
product for the first time.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Guide  
Important Safety Instructions  
For Your Safety  
7) SETUP  
Never open this product under any circumstances. Any repairs or internal  
adjustments should be made only by a trained technician.  
16. Use >> button to select and tap  
ENTER button to enter FAN COOLING  
menu. This menu allow you to control  
how the internal cooling fans operate.  
The menu gives you a choice of Normal,  
Full On and Silent.  
MENU  
FAN COOL[Normal]  
Normal  
Never operate this product with the cover removed.  
ESC  
ENTER  
Do not use your unit immediately after transporting it from a cold place to  
a warm place, as condensation cause the unit to malfunction.  
To prevent fire or shock hazard,keep your unit away from humid areas and  
abnormally hot places.  
17. Use >> button to scroll Normal, Full On  
or Silent. When selected Normal, the dimmer  
pack will keep temperature not higher than 70  
degree C.  
MENU  
FAN COOL[Normal]  
Normal  
The apparatus shall not be exposed to dripping or splashing and that no  
objects filled with liquids, such as vases, shall be placed on the apparatus.  
ESC  
ENTER  
The ventilation should not be impeded by covering the ventilation opening  
with items, such as newspaper, table-cloths, curtains, etc.  
MENU  
FAN COOL[Full On]  
18. When selected Full On,all the time  
the Fans keep in full speed on.  
Full On  
Do not install near any heat sources such as radiators, heat registers,  
stoves, or other apparatus that produce heat.  
ESC  
ENTER  
MENU  
FAN COOL[Silent]  
Caution  
19. When selected Silent, The Fans are running  
in lower speed and the temperature not  
higher than 90 degree C.  
Silent  
ESC  
ENTER  
This product must be grounded.  
No user serviceable parts inside, do not attempt repairs. Should you product  
fail, contact your local dealer.  
MENU  
FAN COOL[Silent]  
Improvement and changes to  
All Rights Reserved!  
20. Tap ENTER button to save your set  
or use ESC button to exit without  
record.  
This product is not for domestic use .  
specifications, design and this  
Silent  
manual, may be made at any time  
This product should be installed and serviced only by suitable qualified personnel.  
All Rights Reserved!  
ESC  
ENTER  
without prior notice.  
Provide occasional ventilation during use.  
Disconnect the power when not use for extended period.  
MENU  
Factory Default  
21. Use >> button to select and tap  
ENTER button to enter DEFAULT  
menu.  
Confirm  
Do not use the unit in places subject to excessive humidity, vibration or  
bumps.  
ESC  
ENTER  
-1-  
-20-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Guide  
General Instructions  
Thanks for you purchasing Botex RMD-1220 Rack Mount Dimmer. RMD-1220 is  
designed to build and expand your lighting control console.It is compact, portable  
and easy to operate by menus.  
7) SETUP  
12. Use >> button to select and tap  
ENTER button to enter DMX Failed menu.  
This menu contains ArtNET Failed Off,  
Hold, Off After 10min, DMX fail ArtNET  
and GoScene##.  
MENU  
DMX Failed  
Off  
Features  
ESC  
ENTER  
-19"/2U rack mount  
-12 channel modular digital dimmer pack,12 ways x 20A per channel  
- High speed Micro Processor  
- Standard USITT DMX-512 (1990)  
- Dual fan cooling  
MENU  
13. In this page, tap UP/DOWN button to  
scroll Off, Hold,  
DMX Failed  
Off  
Off After 10min, DMX  
Fail ArtNET or GoScene##.  
- Dual SCR thyristor  
ESC  
ENTER  
- 16 digital in 2 lines LCD display  
- 20A UL approved MCB x 12  
- Power Requirement:AC 120V~60Hz  
- Connector: Terminal  
MENU  
DMX Failed  
- ArtNET(Ethernet protocol) available  
14. When selected GoScene##, tap >> button  
to activate cursor.  
GoScene01  
ESC  
ENTER  
Physical Dimensions  
MENU  
15. Tap UP/DOWN button to scroll  
GoScene## from 01~99  
DMX Failed  
GoScene02  
ESC  
ENTER  
MENU  
DMX Failed  
GoScene02  
16. In DMXFailed menu, you can  
tap ENTER button to save your set  
or use ESC button to exit without  
record.  
ESC  
ENTER  
-2-  
-19-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Guide  
Technical Specification  
Power Requirements  
Voltage: 120V AC  
Frequency: 60Hz  
7) SETUP  
All RMD-1220 Rack Mount Dimmers must be grounded for safety use.  
7. Use >> button to select and tap  
ENTER button to enter ArtNET Failed  
menu. This menu contains ArtNET Failed  
Off, Hold, Off After 10min, ArtNET fail DMX  
and GoScene##.  
MENU  
ArtNET Failed  
Off  
Dimming Capacity  
Each pack contains twelve dimmers each with a Maximum load of 20A(4.6kW)  
per dimmer-total 55.2kW per dimmer pack.  
ESC  
ENTER  
Dimmer output Connections  
RMD-1220 dimmer pack is available in terminal strips connector.  
MENU  
ArtNET Failed  
8. In this page, tap UP/DOWN button to  
scroll Off, Hold,  
Fail DMX or GoScene##.  
Off  
Control Inputs  
Off After 10min, ArtNET  
ESC  
ENTER  
USITT DMX512(1990) multiplexed digital control and ArtNET(Ethernet protocol)  
are available  
DMX Output  
MENU  
ArtNET Failed  
9. When selected GoScene##, tap >> button  
to activate cursor.  
Via 3Pin/5Pin XLR female XLR socket.  
GoScene01  
DMX Input  
ESC  
ENTER  
Via 3Pin/5Pin XLR male XLR socket and ArtNET(Ethernet protocol).  
Physical  
MENU  
ArtNET Failed  
Length: 482mm  
Width: 501mm  
Height: 89mm  
10. Tap UP/DOWN button to scroll the  
GoScene## from 01~99.  
GoScene99  
ESC  
ENTER  
Weight: 21.5Kg(approx.)  
Environment(Operating)  
Temperature:0 C~37 C  
MENU  
ArtNET Failed  
GoScene99  
11. In ArtNET Failed menu, you can  
tap ENTER button to save your set  
or use ESC button to exit without  
record.  
Relative humidity:60%~90%  
Condensation level: Zero  
ESC  
ENTER  
RMD-1220 is suitable only for use in a dry, internal environment.  
Improvements and changes in specifications and design to this manual and unit may  
be made at any time without prior notice.  
-3-  
-18-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
Operation Guide  
Front View  
7) SETUP  
This menu is to select what action the dimmer pack shoud follow. There are 5 modes  
available in this menu----- Protocol Assign, ArtNET Failed,DMX Failed, Fan Cooling  
and Default.  
MENU  
SETUP  
1. Tap UP/DOWN to scroll SETUP menu.  
Protocol Assign  
ESC  
ENTER  
MENU  
SETUP  
2. Tap >> button to select the mode you want  
enter in.  
ArtNET Failed  
ESC  
ENTER  
MENU  
Protocol Assign  
3. Tap ENTER button to enter the mode  
you selected, say Protocol Assign.  
ChanDDDDDDDDDDDD  
ESC  
ENTER  
MENU  
Protocol Assign  
4. Tap >> button to move cursor and select  
Channel 1~12.  
ChanDDDDDDDDDDDD  
ESC  
ENTER  
5. Tap UP/DOWM button to swap between D(DMX) and A(ArtNET),Tap ENTER  
button to save or tap ESC to exit without record. The page will back to step 1.  
MENU  
MENU  
Protocol Assign  
SETUP  
Protocol Assign  
ChanDDDADDDDDDDD  
ESC  
ENTER  
ESC  
ENTER  
6. Repeat the step from 3~5, you can complete your set for Protocol Assign mode.  
-17-  
-4-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Guide  
Overview  
Front View  
6) CURVES  
This menu is used to select a dimmer curve for any or all the dimmer in system. There  
are 3 dimmer curves available to choice from L-Linear, S-Square and N-NO-DIM.  
1. 2x16 LCD Display  
Shows the current activities or adjustments of menus.  
2. DMX LED Indicator  
MENU  
CURVES  
This LED blinks when DMX signal is present.  
1. Tap UP/DOWN button to scroll to CURVES  
CH:  
menu.  
3. POWER LED Indicator  
ESC  
ENTER  
This LED will light when power source is connected.  
MENU  
CURVES(Linear)  
CH:  
4. ArtNET LED Indicator  
2. Tap ENTER button to enter CURVES  
menu. The cursor is blinking on bar 1.  
This LED will blink when an available Ethernet network is connected.  
ESC  
ENTER  
5. MENU Button  
This button is used to access set-up menus.  
MENU  
CURVES(Linear)  
CH:  
6. >> Button  
3. You can tap >> button to move cursor from  
bar 1 to bar 12.  
This button is used to scroll the sub-menus or move the cursor to right.  
ESC  
ENTER  
7. UP( )/DOWN( ) Button  
Tap UP/DOWN button to scroll through or adjust desired levels, menu  
options during operation.  
4. Tap UP/DOWN button to select Linear, Square or NO-DIM, and tap ENTER button  
to save your setup. The LCD page will back to step 1.  
8. ESC Button  
Tap this button to go back the previous menu level or escape without record.  
MENU  
MENU  
CURVES  
CH:  
CURVES(Square)  
CH:  
S
9. ENTER Button  
All functions must press ENTER button to activate.  
ESC  
ENTER  
ESC  
ENTER  
10. ArtNET Port  
With RJ 45 standard network port, use to connect your PC.  
MENU  
CURVES(NO-DIM)  
CH:  
11. Channel Dimmer Module(x12)  
5. Repeat the step 2~4,you can complete  
your setup for Dimmer Curve.  
S
N
N
The channel dimmer module is incorporated with a 20A UL approval MCB  
(Circuit Breaker) and SCRs (Silicon Controlled Rectifier) .  
Tap ESC button to jump to previous page and  
the current page will not be recorded.  
ESC  
ENTER  
-16-  
-5-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
Operation Guide  
Rear View  
5) PLAY SCENE  
6. Tap UP/DOWN button to scroll the  
scene display mode(Once or Loop),  
Fade time(Fad1s,from 1s~10s) and  
the last scene(E01~E99).  
MENU  
<Once>Fad1s E99  
Sc01  
2
ESC  
ENTER  
OUT  
12  
11  
10  
9
8
6
5
4
3
2
1
7
-5-  
7.Tap ENTER button to Pause  
" " or Play " " the Scene.  
MENU  
<Once>Fad1s E99  
Sc01  
IN  
PIN 1: Ground  
PIN 2: Data  
-
PIN 3: Data  
PIN 4,5: NC  
+
When one scene completed, Scene  
number will increase 1 and the bar  
1~12 will display the output.  
ESC  
ENTER  
4
1
3
MENU  
PLAY SCENE  
Scene  
8. Tap ESC button to back to step 1 and use  
UP/DOWN button select sub-menu Scene.  
ESC  
ENTER  
1. DMX Input  
The XLR connector is used to receive an incoming DMX signal  
MENU  
Single Sc01  
Live  
2. DMX Output  
9.Tap ENTER button to enter Scene menu.  
Used to connect to DMX Input socket of next RMD-1220 for parallel control  
ESC  
ENTER  
3. Power Input  
Single phase input:AC 120V~60Hz,total 75A  
MENU  
10. Tap UP/DOWN button to scroll the Scene  
number. And then tap ENTER button to  
play the Scene you selected,the bar 1~12  
will display the output.  
Three~phase input:AC 120V ~60Hz, total 75A per chase  
Single Sc01  
Live  
4. Output wiring port  
Use to connect to 12 channels output  
ESC  
ENTER  
MENU  
Single Sc01  
Live  
11.Tap ESC button to exit .  
ESC  
ENTER  
-15-  
-6-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Guide  
Overview  
5) PLAY SCENE  
Main power & Output Termination  
MENU  
1. Tap UP/DOWN button scroll to  
PLAY SCENE menu to perform  
scene out.  
PLAY SCENE  
Chase  
ESC  
ENTER  
MENU  
PLAY SCENE  
Scene  
2. In this menu, there are 2 sub-menus,  
Chase and Scene.  
You can tap >> button to select the  
sub-menu you want to enter in.  
ESC  
ENTER  
MENU  
<Once>Fad1s E99  
Sc01  
3. Tap ENTER button to enter Chase.  
ESC  
ENTER  
MENU  
<Once>Fad1s E99  
Sc01  
4. Tap UP/DOWN to scroll Scene number.  
ESC  
ENTER  
MENU  
<Once>Fad1s E99  
Sc01  
5. Tap >> button to move cursor.  
ESC  
ENTER  
-14-  
-7-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Guide  
Operation Guide  
Menus  
4) Scenes REC  
There are 8 menus for RMD-1220:  
1)Home(Live Display)  
2)LOCAL CONTROL  
3)ADDRESS,  
6.Tap ESC BACK Step 1 and use >> button to select Assign sub-menu, tap ENTER  
button enter in.  
MENU  
MENU  
SCENE: [Copy]  
Scene07:ENTER  
SCENE[Assign]00%  
S01:123456789012  
4)SCENE REC  
5)PLAY SCENE  
6)CURVES  
ESC  
ENTER  
ESC  
ENTER  
7)SETUP  
8) INFORMATION.  
MENU  
SCENE[Assign]00%  
S01:123456789012  
7. Tap >> button to move cursor to next  
channel.  
1)Home (Live Display)  
ESC  
ENTER  
Power on this unit, the POWER led will be lit and the LCD shows "Initialize...", then  
enter Home(Live Display) mode automatically. Home as the ROOT position, except  
LOCAL CONTROL and PLAY SCENE, all menu pages will jump to Home page after  
free hand for 5 seconds.  
MENU  
8. Tap UP/DOWN button to scroll Scene  
number and increase/decrease channel  
level.  
SCENE[Assign]00%  
S01:123456789012  
1 2 3 4 5 6 7 8 9 0 1 2  
LIVE  
Initialize...  
ESC  
ENTER  
In Home mode, tap MENU button to enter set-up menus. Then you can tap UP/DOWN  
button to scroll the menu pages.  
MENU  
SCENE[Assign]05%  
S02:123456789012  
9. Tap ENTER button to hold or release  
the selected channel.  
MENU  
LOCAL COTROL00%  
LIVE 123456789012  
MENU  
ADDRESS  
DMX-512A  
ESC  
ENTER  
ESC  
ENTER  
ESC  
ENTER  
MENU  
SCENE[Assign]05%  
S02:123456789012  
ESC  
ENTER  
1 2 3 4 5 6 7 8 9 0 1 2  
LIVE  
10. Tap ESC button to escape last page  
without record.  
ESC  
ENTER  
Tap ESC button to exit and back to Home page.  
-8-  
-13-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Guide  
Operation Guide  
4) Scenes REC  
2) LOCAL CONTROL  
1. Tap UP/DOWN button to scroll to  
SCENES REC menu.  
MENU  
SCENE REC  
Copy  
Local Control menu is to set the output level for the selected dimmers.  
ESC  
ENTER  
MENU  
LOCAL COTROL00%  
1. Use MENU button to enter set-up menus.  
LIVE 123456789012  
MENU  
SCENE REC  
Tap UP/DOWN button to scroll to LOCAL  
2. Tap >> button to swap sub-menu between  
Copy and Assign.  
Assign  
CONTROL menu.  
ESC  
ENTER  
ESC  
ENTER  
MENU  
LOCAL COTROL00%  
LIVE 123456789012  
2. Tap ENTER button to enter LOCAL CONTROL  
menu. The selected channel will keep blinking.  
3. Tap ENTER button to enter the Sub-menu you selected, and tap UP/DOWN  
button to scroll scene number. In this mode, there are total 99 scenes, scene71~  
scene 99 are build in patterns which can be covered with new scene, you can set  
default to resume them.  
ESC  
ENTER  
MENU  
MENU  
SCENE: [Copy]  
Scene06:ENTER  
SCENE: [Copy]  
Scene01:ENTER  
MENU  
LOCAL COTROL00%  
3. You can use >> button move cursor to  
to select the channel you want to adjust.  
ESC  
ENTER  
LIVE 123456789012  
ESC  
ENTER  
ESC  
ENTER  
MENU  
MENU  
SCENE: [Copy]  
Scene06:ENTER  
LOCAL COTROL03%  
LIVE 123456789012  
4. You can use UP/DOWN button to adjust the  
parameter(xx%) for the channel you last  
selected.  
4. Tap >> button move cursor to blinking  
"ENTER" and ready to record.  
ESC  
ENTER  
ESC  
ENTER  
MENU  
MENU  
SCENE: [Copy]  
Scene07:ENTER  
LOCAL COTROL03%  
LIVE 123456789012  
5.Tap ESC button to exit.  
5.Tap ENTER button to record input DMX signal  
to current Scene. This page Scene number  
will increase 1 after signal record. For example,  
the Scene06 increased to Scene07 once Scene06  
was recorded the input singal..  
ESC  
ENTER  
ESC  
ENTER  
-12-  
-9-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Guide  
Operation Guide  
3) Address  
3) Address  
This menu is used to set either the DMX512 start address or ArtNET address(SubNET  
and Universe are available).  
MENU  
7. Tap ENTER button to save your set in memory. Then tap ESC button back  
to step 2, use >> button select ArtNET sub-menu,tap ENTER button to  
enter in.  
ADDRESS  
DMX-512A  
1. Tap UP/DOWN button to scroll to  
ADDRESS menu.  
MENU  
MENU  
ESC  
ENTER  
ADDRESS[ArtNET]  
SubNET:001  
ADDRESS  
ArtNET  
MENU  
ADDRESS  
ESC  
ENTER  
ESC  
ENTER  
2. Tap >> button to select sub-menu  
DMX-512A or ArtNET.  
ArtNET  
ESC  
ENTER  
MENU  
ADDRESS[DMX]  
Start:001  
MENU  
ADDRESS[ArtNET]  
Universe:001  
8. Similarly, in this menu, you can tap  
>> button to swap between SubNET  
and Universe.  
3. Tap ENTER button to enter  
DMX-512A sub-menu.  
ESC  
ENTER  
ESC  
ENTER  
MENU  
ADDRESS[DMX]  
Start:001  
4.Tap ENTER button to activate cursor,  
then tap UP/DOWN button to scroll  
Start address of 12 channels from  
001 to 512.  
MENU  
9. Tap ENTER button to enter the menu  
you selected, secondly tap ENTER  
button to activate cursor.  
ADDRESS[ArtNET]  
SubNET:001  
ESC  
ENTER  
ESC  
ENTER  
5.Tap ENTER button to save your set or use ESC button to exit without record. The  
page will back to the previous step, use >> button to select Patch mode.  
MENU  
ADDRESS[ArtNET]  
10. Tap UP/DOWN button to select from  
000~255.  
SubNET:001  
MENU  
MENU  
ADDRESS[DMX]  
Start:001  
ADDRESS[DMX]  
Patch:CC>>001  
ESC  
ENTER  
ESC  
ENTER  
ESC  
ENTER  
CC is channel from 1~12,  
001 is address from 1~512  
ADDRESS  
ArtNET  
MENU  
11. Tap ENTER button to save in memory  
and tap ESC back to step7.  
6.  
Tap ENTER button to activate cursor,  
then tap UP/DOWN button to scroll  
address and channels, use >> button  
to swap between channels and address.  
MENU  
ADDRESS[DMX]  
Patch:01>>001  
ESC  
ENTER  
ESC  
ENTER  
-10-  
-11-  
Download from Www.Somanuals.com. All Manuals Search And Download.  

EAW Speaker System MQV1394 User Manual
Euro Pro Mixer KM550E User Manual
Fisher Paykel Ventilation Hood RH900CQ User Manual
Fisher Price Fitness Equipment 72408 User Manual
GarrettCom Switch 84 00136 User Manual
GE Door 19230 User Manual
GE Frozen Dessert Maker 681131067652 User Manual
GE Headphones 98991 User Manual
Gemini Music Mixer CS 02 User Manual
Gemini Stereo Amplifier PS 727 User Manual