Elation Professional Indoor Furnishings ELAR 108 PAR RGBW User Manual |
ELAR 108PAR RGBW
Elation Professional™
6122 S. Eastern Ave.
Los Angeles, Ca 90040
Rev. 01/08/2010 – visage
Version 1.1
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
TABLE OF CONTENS
1. General Information……………………………………………………………………… 3
a. Introduction………………………………………………………………………. 3
b. Unpacking………………………………………………………..…………..… 3
c. Customer Support…………………………………………….………………… 3
d. Warranty Registration……………………………………………………..…… 3
2. Safety Instructions………………………………………………………........…………. 5
3. Features……………………………………………………………………………………7
4. General Guidelines………………………………………………………………………. 8
5. Fixture Overview…………………………………………………………………………. 9
6. Mounting and Installation………………………………………………………….……. 12
7. Understanding DMX……………………………………………………………………... 15
a. DMX Cables……..………………………………………………………………. 15
b. DMX Terminator………………………………………………………………….16
c. 3-Pin to 5-Pin Conversion……………………………………………………….17
d. Fixture DMX Addressing.………………………..………………………………16
8. Display Indicators….……………………………………………………..……………… 19
9. Display Menu….……………………………………………………..……………………20
10. DMX Addressing…………………………………………………….…………………… 25
a. Remote DMX Addressing (RDMX)……………………………………………. 25
11. DMX Traits…………………………………………………………………………………27
12. Working with Built-In programs………………………………………………………….35
13. Lens Replacement………………………………………………………………….…….38
14. Cleaning and Maintenance………………………………………………………………39
15. Warranty…………………………………………………………………………………...40
16. Photometric Data………………………………………………………………………… 42
17. Dimensional Drawings………………………………………………….……………….. 43
18. Circuit Schematic………...……………………………………………………………….44
19. Technical Specifications…………………………………………...………….………… 45
©Elation Professional, Los Angeles Ca.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
1. GENERAL INFORMATION
INTRODUCTION: Congratulations, you have just purchased one of the most innovative and
reliable LED fixtures on the market today! The ELAR 108PAR RGBW™ has been designed
to perform reliably for years when the guidelines in this booklet are followed. Please read
and understand the instructions in this manual carefully and thoroughly before attempting to
operate this unit. These instructions contain important information regarding safety during
use and maintenance.
UNPACKING: Thank you for purchasing the ELAR 108PAR RGBW™ by Elation
Professional®. Every ELAR 108PAR RGBW™ has been thoroughly tested and has been
shipped in perfect operating condition. Carefully check the shipping carton for damage that
may have occurred during shipping. If the carton appears to be damaged, carefully inspect
your fixture for damage and be sure all accessories necessary to operate the fixture have
arrived intact. In the event damage has been found or parts are missing, please contact our
customer support team for further instructions. Inside the box you should find: the fixture, a
DMX XLR cable, a safety cable, and this manual. Please do not return this unit to your
dealer without first contacting customer support at the number listed below.
CUSTOMER SUPPORT: Elation Professional® provides a customer support line, to provide
set up help and to answer any question should you encounter problems during your set up
comments or suggestions. For service related issue please contact Elation Professional®.
Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m. Pacific Standard Time.
Voice:
Fax:
(323) 582-3322
(323) 832-9142
E-mail:
Forum:
Warning! To prevent the risk of fire and reduce the risk electrical shock, do not attempt to
operate this fixture with the lens cover removed.
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs
©Elation Professional, Los Angeles Ca.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
yourself. Doing so will void your manufactures warranty.
Please do not discard the shipping carton in the trash. Please recycle whenever possible.
WARRANTY REGISTRATION: The ELAR 108PAR RGBW™ carries a two-year (730 days)
limited warranty. Please fill out the enclosed warranty card to validate your purchase. All
returned service items whether under warranty or not, must be freight pre-paid and
accompany a return authorization (R.A.) number. The R.A. number must be clearly written
on the outside of the return package. A brief description of the problem as well as the R.A.
number must also be written down on a piece of paper and included in the shipping
container. If the unit is under warranty, you must provide a copy of your proof of purchase
invoice. Items returned without a R.A. number clearly marked on the outside of the package
will be refused and returned at customer’s expense. You may obtain a R.A. number by
contacting customer support at (323) 582-3322.
©Elation Professional, Los Angeles Ca.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
2. SAFETY INSTRUCTIONS
To guarantee proper and consistent operation, it is important to
follow the guidelines in this manual. Elation Professional will not
accept responsibility for damages resulting from the misuse of
this fixture due to the disregard of the information printed in this
manual.
1. Always be sure that the fan and the air inlets remain clean and are never
blocked. Allow about 6” (15cm) between this fixture and other devices or a wall
to allow for proper cooling. See page 12.
2. Never touch the fixture during normal operation.
3. Never look directly into the light source. You risk injury to your retina, which may
induce blindness.
4. For safe operation, follow the Installation guide described in chapter six of this
manual. Operating the ELAR 108PAR RGBW™ without suited safety aids such
as safety cables or clamps can increase the risk of damage and/or personal
injury.
5. Qualified and certified personnel should only perform installation.
6. When mounting this fixture, use only the original rigging points included with this
fixture. Any structural modification will void the original manufactures warranty
and may increase the risk of damage and/or personal injury.
7. Do not attempt to operate this fixture if the power cord has become damaged or
frayed.
8. Never open this fixture while in use.
9. This device falls under protection-class I. Therefore it is essential that the device
be grounded properly.
10.Qualified personnel should perform all electrical connections.
11.Be sure the available voltage matches the voltage requirements of the unit. Be
sure the power cord is never crimped or damaged. If the power cord is damaged,
©Elation Professional, Los Angeles Ca.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
replace it immediately with a new one of similar power rating.
12.Always disconnect from main power before performing any type of service or
any cleaning procedure.
13.Only handle the power cord by the plug. Never pull out the plug by tugging the
wire portion of the cord.
14.Please be aware that damages caused by modifications to the device are
not subject to warranty.
Important Notice: Damages resulting from the disregard of safety and general user
instructions found in this user manual are not subject to any warranty claims.
©Elation Professional, Los Angeles Ca.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
3. FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
•
IP65 Rated Fixture
Low power consumption
Minimal heat emission
Maintenance free operation
Equipped with 36 3-Watt (12 x red, 9 x green, 9 x blue, 6 x white)
Silent Operation, convection cooled, no fans
100,000 hours rated LED life
Linear RGBW Color Mixing, infinite color possibilities
13˚ Beam Angle/25˚ Field Angle (15˚ Lens)
USITT DMX-512 Complaint
Preprogrammed colored macros
Strobe-effect with a maximum flash rate of 18fps
DMX-controlled operation or stand-alone operation with Master/Slave-function
7 built-in programs can be called up via DMX-controller
~ 48 preprogrammed scenes per program
Sound-controlled via built-in microphone
Four DMX Modes:
•
•
9 DMX channels
7 DMX channels
5 DMX channels
4 DMX channels (default)
•
•
•
•
•
•
DMX-control via standard DMX-controller
Upgradable firmware via Elation “E-Loader” Data Pack
Electronic Switching Power Supply 100v~240v
Flicker-free operation for television and film
Compact design: fits in 12” box truss
0%~100% Dimming (two dimming options; linear & standard)
©Elation Professional, Los Angeles Ca.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
4. GENERAL GUIDELINES
This fixture is a professional lighting effect designed for use on stage, in nightclubs, in
theatres, and other types of architectural installations. Do not attempt operation or
installation without a proper knowledge on how to do so.
Consistent operational breaks will ensure that the fixture will function properly for many
years to come.
Do not shake the fixture around. Avoid brute force when installing or operating the fixture.
While choosing an installation location, please be sure that the fixture will not be exposed to
extreme heat, moisture, or dust. The minimum distance between the fixture and a wall or flat
surface should be at least 0.5 meter (about 1.5ft). See page 12.
Always install the fixture with an appropriately rated safety cable. When installing the fixture
in a suspended environment always be sure to use mounting hardware no less than M10 x
25 mm, also be sure the hardware is only inserted in the yoke’s mounting holes.
Do not attempt to operate this fixture until you have familiarized yourself with all of its
functions.
Do not permit operation by persons not qualified for operating this type of architectural
fixture. Most damages are the result of improper operation.
Please use the original packaging to transport the fixture in for service.
For your own safety, please read this user manual carefully before installing the device.
©Elation Professional, Los Angeles Ca.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
5. FIXTURE OVERVIEW
©Elation Professional, Los Angeles Ca.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
1. LED Lens Assembly – The lens assembly may be user replaced in the event repair
is needed or a different beam angle is required.
2. LED Display – 4-segment menu display. Used to display the DMX address as well
as all other menu functions.
3. Power Output Lead – This lead is used to jump power to another ELAR 108PAR
RGBW™. Please do not daisy chain power for more than 16 fixtures. To maintain the
integrity of the IP rating, only use proper Elation IP rated power cables.
4. DMX Out Lead – This lead is used to send an incoming DMX signal to the next
fixture in the DMX chain. To maintain the integrity of the IP rating, only use proper
Elation IP rated DMX cables.
5. MENU Button – This button is used to access the fixtures menu functions.
6. Up Button – The up button is used to toggle forward through the menu functions and
settings.
7. Down Button – The down button is used to toggle backwards through the menu
functions and settings.
8. Enter Button – The enter button is used to enter in to a certain menu function or to
lock a menu setting in to memory.
9. Yoke Assembly – This yoke is designed to perform two functions; 1) When split it
can be used as a floor stand bracket. 2) Used to secure a mounting clamp for truss
mounting.
10. Main Power Input Lead – This lead is the main power input lead. When the unit is
the first in a chain or the only fixture to be used, be sure to use the power starter
©Elation Professional, Los Angeles Ca.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
cable that converts a standard Edison 3-prong to the IP rated twist lock connector.
When jumping from fixture to fixture be sure to only use Elation IP rated power
connectors to maintain the IP rating.
11. DMX In Lead – This lead is the main DMX input lead. When the unit is the first in a
chain or the only fixture to be used with a DMX controller, be sure to use the DMX
starter cable that converts a standard 3-pin XLR DMX connector to the IP rated twist
lock connector that is used on the fixture. When jumping from fixture to fixture be
sure to only use Elation IP rated DMX cables to maintain the IP rating.
©Elation Professional, Los Angeles Ca.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
6. MOUNTING AND INSTALLATION
Cautions:
For added protection mount the fixtures in areas outside walking paths, seating areas, and
away from areas were unauthorized personnel might reach the fixture.
Before mounting the fixture to any surface, make sure that the installation area can hold a
minimum point load of 10 times the device’s weight.
Fixture installation must always be secured with a secondary safety attachment, such as an
appropriate safety cable.
To avoid injury, never stand directly below the device when mounting, removing, or servicing
the fixture.
Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE0711-217
for proper installation in Europe To ensure proper installation, only
qualified staff should attempt installation.
Mounting points
Overhead mounting requires extensive experience, including amongst others calculating
working load limits, a fine knowledge of the installation material being used, and periodic
safety inspection of all installation material and the fixture. If you lack these qualifications, do
not attempt the installation yourself. Improper installation can result in bodily injury.
CAUTION!
Be sure a qualified electrician performs all electrical
connections.
Be sure to complete all rigging and installation procedures before connecting the main
power cord to the appropriate wall outlet.
©Elation Professional, Los Angeles Ca.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
Mounting
The ELAR 108PAR RGBW™ is fully operational in any mounting position, hanging
upside-down, side mounted, or set on a flat level surface, etc. Be sure this fixture is kept at
least 0.5m (1.5 feet) away from any flammable materials (decoration etc.). When clamp
mounting; always use and install the supplied safety cable as an added safety measure to
prevent accidental damage in the event of a clamp failure. See the image below.
Clamp Mounting
The ELAR 108PAR RGBW™ provides a unique mounting bracket assembly that allows the
unit to stand on a flat surface or to be hung on truss via a clamp in any safe position (see the
illustration above). Regardless of the mounting option you choose please be sure to refer to
the safety guidelines in this manual to avoid damage to the unit and/or personal injury.
©Elation Professional, Los Angeles Ca.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
When mounting this fixture to truss be sure to secure an appropriately rated clamp to the
hanging yoke using a M10 screw fitted through the center hole of the hanging yoke. As an
added safety measure be sure to attach at least one properly rated safety cable to the fixture.
See illustrations below.
Securing the ELAR 108PAR RGBW™
Always be sure to secure your fixture with a safety cable when
suspending the unit from truss or other means. The fixture
provides a built-in rigging point for a safety cable as illustrated
above. Be sure to only use the designated rigging point for the
safety cable and never secure a safety cable to the hanging
bracket.
©Elation Professional, Los Angeles Ca.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
7. UNDERSTANDING DMX
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most
lighting and controller manufactures as a form of communication between intelligent fixtures
and controllers. DMX allows all makes and models of different manufactures to be linked
together and operate from a single controller. This is possible as long as all the fixtures and
the controller are DMX compliant. A DMX controller sends the DMX data instructions to a
fixture allowing the user to control the different aspects of an intelligent light. DMX data is
sent out as serial data that travels from fixture to fixture via data “IN” and “OUT” leads
located on the fixtures (most controllers will only have output jacks).
DMX Linking: To ensure proper DMX data transmission, always use proper DMX cables
and a terminator. When using several DMX fixtures try to use the shortest cable path
possible. Never split a DMX line with a “Y” style connector. The order in which the fixtures
are connected in a DMX line does not influence the DMX addressing. For example; a fixture
assigned a DMX address of 1 may be placed anywhere in the DMX chain, at the beginning,
at the end, or anywhere in the middle. The DMX controller knows to send data assigned to
address 1 to that fixture no matter where it is located in the DMX chain. The ELAR 108PAR
RGBW™ can be controlled via DMX-512 protocol. The ELAR 108PAR RGBW™ is a fixture
that can operate in 4, 5, 7, or 9 DMX channels (see pages 28-35 for the different DMX traits).
The DMX address is set electronically using the controls on the LED menu.
Cable Requirements: This fixture is designed with special cables for both DMX and power.
These cables are specifically designed to maintain the integrity of the IP rating. When using
this fixture outdoors be sure to ONLY use the Elation cables that have been manufactured to
meet the IP rating.
“First” DMX Cables - Special DMX “First” cables may be purchased from Elation to provide
a means of data communication with standard DMX fixtures for indoor use. These cables will
come with the IP rated twist lock connector on one end and either a 3-pin XLR male or
female connector on the other depending on model. Be sure to only use these cables for
intergrading this fixture in a standard DMX chain.
©Elation Professional, Los Angeles Ca.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
“First” Power Cable – A special power “First” cable is included with every fixture. This
cables is used to provide power to your fixture. This cable comes with the IP rated twist lock
connector on one end and a standard Edison 3-prong, grounded prong on the other end. Be
sure to only use this cable for power distribution and never attempt to connect this cable to
the DMX lines.
You can chain multiple fixtures together through serial linking. Using the IP rated signal
cables provided through Elation. Always be sure to daisy-chain your in and out data
connections, never split or “Y” your DMX connections unless you are using an approved
DMX splitter such as the Elation Opto Branch 4™ or DMX Branch/4™.
DMX-512 connection with DMX terminator
A DMX terminator should be used in all DMX lines especially in longer runs. The use of a
terminator may avoid erratic behavior in your DMX line. A terminator is a 120 ohm 1/4 watt
resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy
chain to terminate the line. Using a line terminator (Elation part: DMX T PACK) will decrease
the possibilities of erratic behavior.
©Elation Professional, Los Angeles Ca.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA
transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX
line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must
be used, these adaptors are readily available at most electric stores. The following chart
details a proper cable conversion.
Fixture DMX addressing;
All fixtures should be given a DMX starting address when using a DMX controller, so the
correct fixture responds to the correct control signal. This digital starting address is the
channel number from which the fixture starts to “listen” to the digital control information sent
out from the DMX controller. The allocation of this starting DMX address is achieved by
setting the correct DMX address on the digital display located on the back of the fixture.
You can set the same starting address for all fixtures or a group of fixtures, or set different
address for each individual fixture. Be advised that setting all you fixtures to the same DMX
address will subsequently control all fixtures in the same fashion, in other words, changing
the settings of one channel will affect all the fixtures simultaneously.
If you set each fixture to a different DMX address, each unit will start to “listen” to the
channel number you have set, based on the quantity of control channels (DMX channels) of
each fixture. That means changing the settings of one channel will only affect the selected
fixture.
In the case of the ELAR 108PAR RGBW™, which is up to a nine channel fixture, you should
©Elation Professional, Los Angeles Ca.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
set the starting DMX address of the first unit to 1, the second unit to 10 (9 + 1), the third unit
to 19 (9 + 10), and so on.
Note: During start-up the ELAR 108PAR RGBW™ will automatically detect whether a DMX
data signal is being received or not. If a DMX data signal is being received, the display will
show "A.XXX" (XXX representing the actual DMX address). If the fixture is not receiving a
DMX signal the display will flash "A.XXX" (XXX representing the actual DMX address).
If your fixture is connected to a DMX controller and the display is flashing (not receiving a
DMX signal), please check the following:
-
The 3-pin or 5-pin XLR plug (cable with DMX signal from controller) may not be
connected or is not inserted completely into the DMX input jack.
The DMX controller is switched off or defective.
-
-
The DMX cable from the controller merging with included IP Rated Cable adapter is
not connected securely
-
-
The DMX cable or connector is defective.
A DMX terminator has been inserted into the last fixture in your DMX chain.
©Elation Professional, Los Angeles Ca.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
8. DISPLAY LED INDICATOR.
The ELAR 108PAR RGBW ™ has a LED indicator on the display. This indicator is designed
to give a quick visual indication of the fixtures’ DMX status. The illustration below details the
functionality of the LED indicators.
The LED indicator represents DMX signal:
• If the indicators is on, a clean DMX signal is present
• If the indicator is off, there is no DMX signal present
©Elation Professional, Los Angeles Ca.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
9. DISPLAY MENU
Default settings shaded.
VALU
A001~AXXX (AXXX) DMX address setting
<ADDR>
SLAV
ON/OFF
Set as Slave
RDMX
ON/OFF
Change address via DMX
Run Auto program
<RUN>
<DISP>
AUTO
ALON/MAST
D-XX D-00(DXXX)
ON/OFF
MODE
SET
VALU
Display DMX value
Flip display
FLIP
D ON
ON/OFF
Delay shutting off LED display
DMX channel Mode
Status while there is no DMX
Default setting
<CHAN>
<FAIL>
4CH/5CH/7CH/9CH
OFF/HOLD/AUTO
ON/OFF
<DFSE>
<VER>
V-1.0~V-9.9
Software version
<CH01>
~<CH09>
01 XX (00~FFH)
09 XX (00~FFH)
MANL
TIME
Manual adjust intensity
<LIFE>
0000~9999(hours)
CXXX
Life time of machine running
Password of clear time ”038”
Clear machine running time
Select steps of program
<CODE>
<CLFE>
<STEP>
ON/OFF
S-01~S-48
01 XX (00~FFH)
09 XX (00~FFH)
C-01~C-09
EDIT
<SC01>
~<SC48>
Edit the internal scenes
FADE
TIME
XXX
XXX.X (000.1s~999.9s)
Remarks:
1) If the fixture does not receive a DMX signal the menu display will flash
repeatedly.
2) TIME: Adjust the hold time for each scene in built-in chase programs.
3) FADE: Adjust the fade time between each scene in the built-in programs.
9.1 “MODE” - Function Mode:
9.1.1 <ADDR> - DMX address setting – This function is used to set or adjust the
fixture’s starting DMX address. Every device controlled by DMX has to have a unique
starting address. The addressing feature is what allows DMX to function properly. The
DMX address of a fixture is what allows it to communicate with a controller properly. The
DMX addressing also allows the fixture to ignore any DMX information coming from the
controller that is not meant specifically for the fixture. Because each fixture is connected
©Elation Professional, Los Angeles Ca.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
in a daisy-chain fashion it is imperative to assign a proper and unique starting DMX
address to each and every fixture. The DMX address is non-destructive and will remain
in the fixture’s memory even when the power to the unit is switched off. Memory is
backed-up and retain by an internal power source that should last about five years. For
proper DMX addressing see “DMX Addressing” on page 25 of this user manual.
“VALU” - Display the DMX 512 value of each channel
With this function you can display the DMX 512 value of each channel. The display
will automatically detail the changing DMX values as they are received from the
controller.
“SLAV” - Slave setting for Master/Slave Operation
With this function, you can define the device as slave for operation in Master/Slave
mode. Each slave setting will have a different function for a dynamic lightshow
without a controller.
“RDMX” - Address via DMX - This function allows the DMX address to remotely be
adjusted from a DMX console. This setting requires special settings for both the
controller and the fixture. RDMX is on by default. For operational instructions please
see Section 10/Page 25 of this manual “Remote DMX addressing.”
9.1.2 <RUN> - Internal Program Settings
This function allows the internal programs to run in either stand-alone or master/salve
mode. In “Master” mode the fixture will send DMX data to other fixtures connect via the
DMX chain. In “Alone” mode the fixture will operate as a single fixture. The program for
this mode is selected in the “Select program” section of the control menu. You can set
the number of steps under “Edit program”. You can edit the individual scenes under
“Edit scenes”. With this function, you can run the individual scenes either automatically,
i.e. with the adjusted Step-Time.
©Elation Professional, Los Angeles Ca.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
9.1.3 <DISP> - Menu Display Settings
This function allows the internal programs to run in either stand-alone or master/salve
DMX chain. In “Alone” mode
“VALU” - Display the DMX 512 value of each channel
This function will electronically display the current DMX value for any channel that is
currently being adjusted. The display will automatically detail the changing DMX
values as they are received from the controller. This function is “off” by default.
“FLIP” – This function will flip the display readout by a 180˚ allowing for better
visualization when the fixture is mounted in an inverted position.
“D ON” – The display is designed to turn off during normal operation to avoid
excessive light in situations that require an extremely dark environment. This
function will adjust the time delay the fixture will remain on before it turns off. This
function is disabled as default.
9.2 “SET” – Fixture Personality Settings:
These functions set specific running modes and operating parameters.
<CHAN> DMX Mode settings
This function allows the fixture to run in different DMX channel modes. Four modes are
available; 4 channel, 5 channel, 7 channel or 9 channel. See “DMX Traits” beginning on
page 28 for a detailed explanation of the different DMX modes.
<FAIL> DMX Fault Protection
This function dictates how the fixture will operate in the event DMX signal is suddenly
lost while operating in DMX mode. The three fail safe modes are; 1) “OFF” which will
blackout all light output. 2) “HOLD,” which will hold the last DMX command, or 3 “AUTO,”
which will put the fixture in sound-active mode.
©Elation Professional, Los Angeles Ca.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
<DFSE> - Restore Default
This function is used to restore the factory settings of the device. All settings will be set
back to the default values (shaded). Any edited scenes will be lost.
<VER> Software Version
This function will display the current firmware version.
9.3 “MANL” – Manual Fixture Settings:
This function allows the each of the nine DMX channels to be controlled manually. This
will allow the fixture to be preset to a specific color or built-in program without the use of
a DMX console.
9.4 “TIME” – Operating Hours
These functions will detail different time functions associated with the fixture.
<LIFE> (0000~9999 Hours)
This function tracks the running time of the fixture from the point it was last cleared.
Where “XXXX ”represents the total number of running hours. This time is none
destructive and will remain in the fixtures memory indefinitely. Use this time to track
rentals or show durations.
<CODE> Clear run time access code
This lock-out code prevents the current run time from being erased accidently. The
access code is “038”
<CLFE> Clear Fixture Run Time
This function resets the run time to zero.
9.5“Edit” Internal Program Settings:
The fixture comes equipped with a built-in DMX recorder that allows custom programs to
be installed and recalled directly from the fixture’s control board. Programs can be
created and stored using the fixture’s control board or by using an external DMX
©Elation Professional, Los Angeles Ca.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
controller. For detailed instructions on how to complete this task please see “Working
with Built-In Programs” Section 12/ Page 35.
9.5.1 Select program – This function allows the user to select one of ten of the user
defined built-in programs. This program is then accessed in “Function Mode” under
“Program Run.”
9.5.2 Edit program – This function allows the user to edit the built-in programs.
9.5.3 Edit Scenes – This function allows the user to edit or define the actual scenes that
are stored in the user defined built-in programs that are accessed in the previous
step.
©Elation Professional, Los Angeles Ca.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
10. DMX ADDRESSING
Setting the DMX address - After the fixture is turned “ON” it will immediately complete a
reset process that test all the fixture’s functions. When the reset process concludes the LCD
will display the fixture’s current DMX address. If the fixture is not receiving a DMX signal, the
display will flash continuously. To set or adjust a DMX address, please follow the procedure
below:
1. Toggle through the menu by pressing the Up and Down buttons until the display
reads “Addr=XXX.” Tap the enter button to make changes to the address.
2. While the display is flashing use the “UP” and “DOWN” buttons to select a new
address. Once the new address has been selected, lock the new address into
the fixture’s memory by pressing the “ENTER” button.
The DMX address is non-volatile and will remain in the fixture’s memory even when the
power to the unit is switched off. Memory is backed-up and retain by an internal power
source that should last about five years
Remote DMX addressing (RDMX) / Address Via DMX- This function allows the DMX
address to be changed remotely from a DMX console. This setting requires special settings
for both the controller and the fixture. This function may be turned on and off, and is “ON” be
default. Follow the procedure listed below to access the RDMX functions:
Fixture Settings:
1. Access the main menu and use the UP or DOWN to get to the
“Personality” menu, then press ENTER
2. Once in the “Personalities” menu, tap the UP or Down to get to the
“Status Settings “ menu, press ENTER.
3. Once in the “Status Settings” tap the UP or Down to get to the “Address via
DMX” function and press ENTER.
4. “Address via DMX” is the function that turn the RDMX function on and off.
Press ENTER and be sure the function is turned on.
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
©Elation Professional, Los Angeles Ca.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
Controller Settings:
1. Set the DMX value of channel 1 to a value of 7.
2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is
set to "7" you can adjust the starting address between 1 and 255. When
set to "8" you can adjust the starting address between 256 and 511.
3. Use channel 3 to set your desired DMX starting address. For example: If
you want to set the starting address to 57, set channel 1 to a value of “7,”
set channel 2 to a value of “7” and use channel 3 to set your address to
57 by selecting a channel value of 57. Example 2: If you want to set the
starting address to 420, set channel 1 to a value of “7,” channel 2 to "8"
and channel 3 to "164" (256+164=420).
4. Wait for approximately 20 seconds for the unit to complete the
address reset function.
©Elation Professional, Los Angeles Ca.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
11.DMX TRAITS
DMX Operation Notes:
The fixture will function in DMX mode whenever the unit is receiving a DMX signal. Please
note that this will override all manual settings.
This unit will keep and retain the last DMX command in the event of DMX signal failure. To
reset the fixture you must turn the power off.
DMX CHANNEL TRAITS
The charts below and on the preceding pages outline the different DMX traits for the three
different DMX modes.
4-Channel mode: In this mode channel one controls all the red LEDs, channel two controls
all the green LEDs, channels three controls all the blue LEDs, and channel four controls all
the white LEDs.
©Elation Professional, Los Angeles Ca.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
DMX channel’s functions and their values (4-Channel Mode):
Channel 1 - Red:
0-255
Red (0-Black, 255 - 100% Red)
Channel 2 - Green:
0-255
Green (0-Black, 255 - 100% Green)
Channel 3 - Blue:
0-255
Blue (0-Black, 255 - 100% Blue)
Channel 4 - White:
0-255
White (0-Black, 255 - 100% White)
5-Channel mode: In this mode channel one controls all the red LEDs, channel two controls
all the green LEDs, channels three controls all the blue LEDs, channels four controls all the
white LEDs, and channel five will control the master dimming level.
©Elation Professional, Los Angeles Ca.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
DMX channel’s functions and their values (5-Channel Mode):
Channel 1 - Red:
0-255
Red (0-Black, 255 - 100% Red)
Channel 2 - Green:
0-255
Green (0-Black, 255 - 100% Green)
Channel 3 - Blue:
0-255
Blue (0-Black, 255 - 100% Blue)
Channel 4 - White:
0-255
White (0-Black, 255 - 100% White)
Channel 5 - General dimming
0-255
Dimming (0-Black, 255- 100%)
7-Channel mode: In this mode channels 1~4 are used to control the RGBW LEDs and
channels 5~7 will control special features. 7-Channel Mode: The charts below and on the
next page detail the DMX channel layout for 7-channel assignment.
©Elation Professional, Los Angeles Ca.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
DMX channel’s functions and their values (7-Channel Mode):
Channel 1 - Red:
0-255
Red (0-Black, 255-100% Red)
Channel 2 - Green:
0-255
Green (0-Black, 255- 100% Green)
Channel 3 - Blue:
0-255
Blue (0-Black, 255- 100% Blue)
Channel 4 - White:
0-255
White (0-Black, 255- 100% White)
Channel 5 - Color Temperature:
0
No function
1~255
Color Temperature (2700K-7200K)
Channel 6 - Color macros:
0
No function
1-7
R02 Bastard Amber
R04 Medium Amber
R09 Pale Amber Gold
R316 Gallo Gold
R21 Golden Amber
R26 Light Red
8-15
16-23
24-31
32-39
40-47
48-55
56-63
64-71
72-79
80-87
88-95
96-103
R27 Medium Red
R36 Medium Pink
R339 Broadway Pink
R344 Follies Pink
R52 Light Lavender
R54 Special Lavender
R57 Lavender
104-111 R59 Indigo
112-119 R361 Hemsley Blue
120-127 R362 Tipton Blue
128-135 R64 Light Steel Blue
©Elation Professional, Los Angeles Ca.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
136-143 R67 Light Sky Blue
144-151 R68 Sky Blue
152-159 R69 Brilliant Blue
160-167 R76 Light Green Blue
168-175 R79 Bright Blue
176-183 R80 Primary Blue
184-191 R382 Congo Blue
192-199 R87 Pale Yellow Green
200-207 R89 Moss Green
208-215 R91 Primary Green
216-223 L200 Double CTB
224-231 L201 Full CTB
232-239 L202 1/2 CTB
240-247 L119 Dark Blue
248-255 White
Channel 7 - General dimming/speed:
0-255
Dimming (0-Black, 255- 100%)
Speed from slow to fast - when running internal programs
Speed from slow to fast - when running gradient effect
9-Channel mode: In this mode channels 1~4 are used to control the RGBW LEDs and
channels 5~7 will control special features. 9-Channel Mode: The charts below and on the
next page detail the DMX channel layout for 9-channel assignment.
©Elation Professional, Los Angeles Ca.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
DMX channel’s functions and their values (9-Channel Mode):
Channel 1 - Red LED:
0-255
Red (0-Black, 255-100% Red)
Channel 2 - Green LED:
0-255
Green (0-Black, 255-100% Green)
Channel 3 - Blue LED:
0-255
Blue (0-Black, 255-100% Blue)
Channel 4 - White LED:
0-255
White (0-Black, 255-100% White)
Channel 5 - Color Temperature:
0
No function
1-255
Color Temperature (2700K-7200K)
Channel 6 - Color Macros:
0
No function
1-7
R02 Bastard Amber
©Elation Professional, Los Angeles Ca.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
8-15
16-23
24-31
32-39
40-47
48-55
56-63
64-71
72-79
80-87
88-95
96-103
R04 Medium Amber
R09 Pale Amber Gold
R316 Gallo Gold
R21 Golden Amber
R26 Light Red
R27 Medium Red
R36 Medium Pink
R339 Broadway Pink
R344 Follies Pink
R52 Light Lavender
R54 Special Lavender
R57 Lavender
104-111 R59 Indigo
112-119 R361 Hemsley Blue
120-127 R362 Tipton Blue
128-135 R64 Light Steel Blue
136-143 R67 Light Sky Blue
144-151 R68 Sky Blue
152-159 R69 Brilliant Blue
160-167 R76 Light Green Blue
168-175 R79 Bright Blue
176-183 R80 Primary Blue
184-191 R382 Congo Blue
192-199 R87 Pale Yellow Green
200-207 R89 Moss Green
208-215 R91 Primary Green
216-223 L200 Double CTB
224-231 L201 Full CTB
232-239 L202 1/2 CTB
240-247 L119 Dark Blue
248-255 White
Channel 7 - Internal programs:
0-10
11-40
41-70
Without internal program
Internal program 1
Internal program 2
©Elation Professional, Los Angeles Ca.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
71-100
Internal program 3
101-130 Internal program 4
131-160 Internal program 5
161-190 Internal program 6
191-220 Internal program 7
221-255 Gradient effect
Channel 8 - Shutter, strobe:
0-31
32-63
64-95
96-127
Blackout (All LEDs Off)
Open (LEDs Active)
Strobe effect slow to fast
Open (LEDs Active)
128-159 Pulse-effect in sequences
160-191 Open (LEDs Active)
192-223 Random strobe effect slow to fast
224-255 Open (LEDs Active)
Channel 9 - General dimming/speed:
0-255
Dimming (0-Black, 255- 100%)
Speed from slow to fast - when running internal programs
Speed from slow to fast - when running gradient effect
©Elation Professional, Los Angeles Ca.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
12. WORKING WITH BUILT-IN PROGRAMS
The fixture comes equipped with a built-in DMX recorder that allows custom programs to be
installed and recalled directly from the fixture’s control board. Programs can be created and
stored using the fixture’s control board or by using an external DMX controller. The following
instructions will detail the procedures for using the on-board system menu as well as using a
DMX compliant controller.
Memory Statistics:
Quick Access Programs (Program Part): 3
Total Number of Programs: 10
Maximum Number of Steps (Scenes) per a Program: 64
Total Number of Scenes (Steps): 250
Step 1 – Building Scenes.
The control will store a maximum of 250 scenes. These scenes are then used to create the
programs. A program can store one or a maximum of 64 scenes. Keep in mind that a scene
can only be access when it is stored in a “Program.” If you wish to build a static scene (a
scene consisting of no movement) for a logo or gobo projection, the scene must be stored
inside a program. To build a scene follow the instructions below:
•
•
•
Access the main menu and toggle to “Edit Programs” which is menu function 8.
Then tap the “ENTER” button and toggle to “Edit Scenes,” menu function 8-3.
When you get to the “Edit Scenes” function tap the “ENTER” button. The screen will
then change to Edit Scene 001, this will be menu function 8-3-1. You can then press
the “ENTER” button to begin to edit scene 1 or use the “UP” and “DOWN” buttons to
toggle to access scenes 2-250.
•
Once in the scene edit screen you have access to the functions listed below.
Tapping the “ENTER” button will instantly allow you to change the values of the
selected function in real time. The values can be adjusted from 0~250. Once you
achieved your desired value tap the “ENTER” button once again to automatically
©Elation Professional, Los Angeles Ca.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
lock the value into the scenes memory. You can repeat the procedure for all
functions listed below:
-
-
-
-
-
-
-
-
-
“Auto Program” – Allows access to all of the fixture’s DMX traits.
“Red” – adjust all of the red LED values
“Green” – adjust all of the green LED values
“Blue” – adjust all of the blue LED values
“White” – adjust all of the white LED values
“Strobe” – adjust the strobe
“Dimmer” – adjust the dimmer intensity
“Scene Time” – set the hold time for the scene
“Input By Out” – this function will store a scene from an external DMX
console. See the next section for scene editing via an external DMX
controller.
Step 1B – Building Scenes from an External DMX Controller
The fixture includes a simple built-in DMX recorder. This recorder allows you to build a
scene using your own DMX console. That scene can then be sent to the fixture and be
stored inside one of the fixture’s scene storage banks. Many people may find this procedure
easier and quicker than using the on board menu functions as in “Step 1.” To store a scene
from an external DMX controller follow the procedures below:
-
-
Using your DMX control build and store scenes as you normally would.
Once you have built all your required scenes, enter the fixtures main menu
and toggle to
Step 2 – Editing Programs.
The control will store a maximum of 10 programs. A program can store one or a maximum of
64 scenes. Keep in mind that a scene can only be access when it is stored inside one of the
10 available programs. Follow the procedure below to build an internal program:
•
•
•
Access the main menu and toggle to “Edit Programs” which is menu function 8.
Then tap the “ENTER” button and toggle to “Program 1” menu function 8-2-1.
When you get to the “Program 1” function tap the “ENTER” button. The screen will
then change to Edit Steps 01, this will be menu function 8-2-1-1. Use the “UP” and
©Elation Professional, Los Angeles Ca.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
“DOWN” buttons to toggle through the scenes created in “Step 1.” Press the
“ENTER” button to add a scene to the program. Tapping the “Enter” button will
automatically lock the selected scene into the programs’ memory. Repeat the
process until all the desired scenes have been added to the program. Each program
can store a maximum of 64 scenes.
•
To test the program access “Program Test” in the “Program Edit” menu function.
Step 3 – Playing a Program
To initiate a program follow the procedure below:
•
Access the main menu and use the “Up” and “Down” to toggle to “Function Mode”
and tap the “Enter” button.
•
•
In the next screen select “Auto Program” and tap the “Enter” button.
There are now two selections, “Master” and “Alone.” Select “Master” when running
multiple fixtures in a master/slave configuration. See section 10.2 “Master/ Slave
Operation” on page 33 for proper set-up instructions. Select “Alone” when running a
single fixture or when multiple fixtures in stand-alone mode. See section 10.1
“Stand-Alone Operation” on page 32 for proper set-up instructions.
The 3 Slave groups run the Auto Program in certain time segments, as shown in the
following diagram:
©Elation Professional, Los Angeles Ca.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
13. LENS REPLACEMENT
The ELAR 108PAR RGBW comes with a removable front cover that allows the lens
assembly to be changed out to achieve different beam angles.
Lens cover is held in place by two ¼ turn locking fasteners. To remove the cover; 1) Turn the
locking fasteners in a counter-clockwise direction. 2) Once the fasteners are loose lift the
cover straight up to expose the inner lens (see illustration below). 3) Locate the 8 securing
screws on the inner cover and remove them. 4) Remove the inner cover to access the lens
kit (see second illustration below). Once the lenses are changed reassemble in reverse
order.
©Elation Professional, Los Angeles Ca.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
14. CLEANING AND MAINTENANCE
Consider the following points during normal service and inspection:
1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may
fall out during normal operation resulting in damage or injury as larger parts could fall.
2. Electric power supply cables must not show any damage, material fatigue or
sediments. Never remove the ground prong from the power cable.
Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never
use alcohol or solvents.
There are no user serviceable parts inside this fixture, please refer all other service issues to
an authorized Elation service technician.
Should you need any spare parts, please order genuine parts from your local dealer.
©Elation Professional, Los Angeles Ca.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
15.
2-YEAR LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional®
products to be free of manufacturing defects in material and workmanship for a period of two
years, (730 days) from the date of purchase. This warranty shall be valid only if the product
is purchased within the United States of America, including possessions and territories. It is
the owner’s responsibility to establish the date and place of purchase by acceptable
evidence, at the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All
shipping charges must be pre-paid. If the requested repairs or service (including parts
replacement) are within the terms of this warranty, Elation Professional® will pay return
shipping charges only to a designated point within the United States. If the entire instrument
is sent, it must be shipped in its original package. No accessories should be shipped with the
product. If any accessories are shipped with the product, Elation Professional® shall have no
liability what so ever for loss of or damage to any such accessories, nor for the safe return
thereof.
C.
This warranty is void if the serial number has been altered or removed; if the product is
modified in any manner which Elation Professional® concludes, after inspection, affects the
reliability of the product; if the product has been repaired or serviced by anyone other than
the Elation Professional® factory unless prior written authorization was issued to purchaser
by Elation Professional®; if the product is damaged because not properly maintained as set
forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintenance, cleaning
or periodic check-up. During the period specified above, Elation Professional® will replace
defective parts at its expense, and will absorb all expenses for warranty service and repair
labor by reason of defects in material or workmanship. The sole responsibility of Elation
Professional® under this warranty shall be limited to the repair of the product, or replacement
thereof, including parts, at the sole discretion of Elation Professional®. All products covered
by this warranty were manufactured after January 1, 1990, and bare identifying marks to that
©Elation Professional, Los Angeles Ca.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
effect.
E. Elation Professional® reserves the right to make changes in design and/or improvements
upon its products without any obligation to include these changes in any products
theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any
accessory supplied with products described above. Except to the extent prohibited by
applicable law, all implied warranties made by Elation Professional® in connection with this
product, including warranties of merchantability or fitness, are limited in duration to the
warranty period set forth above. And no warranties, whether expressed or implied, including
warranties of merchantability or fitness, shall apply to this product after said period has
expired. The consumer’s and or Dealer’s sole remedy shall be such repair or replacement as
is expressly provided above; and under no circumstances shall Elation Professional® be
liable for any loss or damage, direct or consequential, arising out of the use of, or inability to
use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® Products
and supersedes all prior warranties and written descriptions of warranty terms and
conditions heretofore published.
©Elation Professional, Los Angeles Ca.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
16.
PHOTOMETRIC DATA
©Elation Professional, Los Angeles Ca.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
17.
DIMENSIONAL DRAWINGS
©Elation Professional, Los Angeles Ca.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
18.
CIRCUIT SCHEMATIC
©Elation Professional, Los Angeles Ca.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
19.
TECHNICAL SPECIFICATIONS
Power supply:
100v~240v / 50Hz~60Hz AC
Maximum 120w
IP65
Power consumption:
IP Grade:
LED Configuration:
36 x 3 Watt
(12 x Red, 9 x Green, 9 x Blue, 6 x White)
IP65
IP Rating:
Weight:
6 Kgs / 15.2Lbs
DMX Channels:
DMX Drive:
9, 7, 5, or 4 (default) Channel mode
Standard DMX-512,
3 pole IP Rated Locking Connector; [+] = Pin 3 [-] = Pin 2
[Ground] = Pin 1.
Color Mixing:
Beam Angle:
Fuse:
RGBW Color Additive Mixing
13˚Beam Angle/25˚ Field Angle (15˚ Lens)
GMA 220v~2A (Internal)
Dimmer:
Continuous Dimming 0~100%
Electronic Strobe 0~18 Fps
100,000 Hours Rated Life
(232 x 220 x 260) mm
Strobe:
Lamp Life:
Dimensions:
9.13” x 8.66” 10.24”
Please Note: Specifications and improvements in the design of this unit and this manual are
subject to change without any prior written notice.
©Elation Professional, Los Angeles Ca.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
ELAR 108PAR RGBW™
©Elation Professional, Los Angeles Ca.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Elation Professional
6122 S. Eastern Ave.
Los Angeles, CA. 90040
323-582-3322 / 323-832-9142 fax
Rev. 01/08/2010 – visage
Version 1.1
Download from Www.Somanuals.com. All Manuals Search And Download.
|