Elation Professional Home Safety Product 100WW User Manual

ELED Fresnel 100WW  
Introduction  
Unpacking: Thank you for purchasing the ELED Fresnel 100WW by  
Elation Professional®. Every ELED Fresnel 100WW has been thoroughly  
tested and has been shipped in perfect operating condition. Carefully  
check the shipping carton for damage that may have occurred during  
shipping. If the carton appears to be damaged, carefully inspect your  
fixture for any damage and be sure all accessories necessary to oper-  
ate the unit has arrived intact. In the case damage has been found or  
parts are missing, please contact our customer support number for  
further instructions. Do not return this unit to your dealer without first  
contacting customer support.  
ELED FRESNEL 100WW  
Introduction: The ELED Fresnel 100WW is part of Elation Profession-  
als® continuing pursuit for creating high quality affordable intelligent  
fixtures. The ELED Fresnel 100WW is a powerful DMX intelligent LED  
warm white spot. The unit can be controlled manually or via DMX con-  
troller.  
Customer Support: ©Elation® provides a customer support line, to  
provide set up help and to answer any question should you encounter  
problems during your set up or initial operation. You may also visit us  
tions. Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m.  
Pacific Standard Time.  
Voice:  
Fax:  
(323) 582-3322  
(323) 832-9142  
E-mail:  
Warning! To prevent or reduce the risk of electrical shock or fire, do  
not expose this unit to rain or moisture.  
Caution! There are no user serviceable parts inside this unit. Do not  
attempt any repairs yourself, doing so will void your manufactures war-  
ranty. In the unlikely event your unit may require service please contact  
©Elation customer support.  
PLEASE recycle the shipping carton when ever possible.  
User Instructions  
©Elation Professional®  
6122 S. Eastern Ave.  
Los Angeles CA. 90040  
7/10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELED Fresnel 100WW  
DMX Set Up  
ELED Fresnel 100WW  
DMX Set Up  
Power Supply: The ELED Fresnel 100WW™ contains an electronic  
ballast, which will auto sense the voltage when it is plugged into the  
power source. With the electronic ballast you do not need to worry  
about wall voltage, this unit can be plugged in anywhere. Also be sure  
to only use the included I.E.C. power cable supplied with the unit.  
Notice: Be sure to follow figures two and three when making your own  
cables. Do not use the ground lug on the XLR connector. Do not con-  
nect the cable’s shield conductor to the ground lug or allow the shield  
conductor to come in contact with the XLR’s outer casing. Grounding  
the shield could cause a short circuit and erratic behavior.  
COMMON  
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-  
tocol used as a form of communication between intelligent fixtures  
and controllers. A DMX controller sends DMX data instructions from  
the controller to the fixture. DMX data is sent as serial data that trav-  
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-  
minals located on all DMX fixtures (most controllers only have a DATA  
“OUT” terminal).  
1
2
1
2
DMX +  
DMX -  
DMX512 OUT  
3-PIN XLR  
DMX512 IN  
3-PIN XLR  
3
3
Figure 2  
XLR Female Socket  
XLR Male Socket  
XLR Pin Configuration  
Pin 1 = Ground  
1 Ground  
2 Cold  
2 Cold  
1 Ground  
Pin 2 = Data Compliment (negative)  
3 Hot  
3 Hot  
Pin 3 = Data True (positive)  
DMX Linking: DMX is a language allowing all makes and models of  
different manufactures to be linked together and operate from a single  
controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX  
fixtures try to use the shortest cable path possible. The order in which  
fixtures are connected in a DMX line does not influence the DMX ad-  
dressing. For example; a fixture assigned a DMX address of 1 may be  
placed anywhere in a DMX line, at the beginning, at the end, or any-  
where in the middle. When a fixture is assigned a DMX address of 1,  
the DMX controller knows to send DATA assigned to address 1 to that  
unit, no matter where it is located in the DMX chain.  
Figure 3  
Special Note: Line Termination. When longer runs of cable are  
used, you may need to use a terminator on the last unit to avoid erratic  
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-  
nected between pins 2 and 3 of a male XLR connector (DATA + and  
DATA -). This unit is inserted in the female XLR connector of the last  
unit in your daisy chain to terminate the line. Using a cable terminator  
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic  
behavior.  
Termination reduces signal errors and  
1
avoids signal transmission problems  
3
and interference. It is always advisable  
2
to connect a DMX terminal, (Resistance  
Data Cable (DMX Cable) Requirements (For DMX Operation):  
The ELED Fresnel 100WW™ can be controlled via DMX-512 proto-  
col. The ELED Fresnel 100WW™ can be either a 1 or 2 channel DMX  
unit. The DMX address is set on the back panel of the ELED Fresnel  
100WW™. Your unit and your DMX controller require a approved DMX-  
512 110 Ohm Data cable for data input and data output (Figure 1). We  
recommend Accu-Cable DMX cables. If you are  
120 Ohm 1/4 W) between PIN 2 (DMX-)  
and PIN 3 (DMX +) of the last fixture.  
Figure 4  
5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR  
connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures  
may be implemented in a 3-pin XLR DMX line. When inserting standard  
5-pin XLR connectors in to a 3-pin line a cable adaptor must be used,  
these adaptors are readily available at most electric stores. The chart  
below details a proper cable conversion.  
making your own cables, be sure to use standard  
110-120 Ohm shielded cable (This cable may be  
3-Pin XLR to 5-Pin XLR Conversion  
purchased at almost all professional sound and  
lighting stores). Your cables should be made with  
a male and female XLR connector on either end  
of the cable. Also remember that DMX cable must  
Conductor  
Ground/Shield  
3-Pin XLR Female (Out)  
5-Pin XLR Male (In)  
Pin 1  
Pin 1  
Pin 2  
Pin 3  
Data Compliment (- signal)  
Data True (+ signal)  
Not Used  
Pin 2  
Pin 3  
Do Not Use  
Do Not Use  
Not Used  
be daisy chained and cannot be split.  
Figure 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELED Fresnel 100WW  
Operating Instructions  
ELED Fresnel 100WW  
Operating Instructions  
3. To run the 1 Channel Mode, press the MODE button until “XXX1”  
is displayed. This is the DMX addressing for the 1 Channel Mode.  
4. To run the 2 Channel Mode, press the MODE button until “XXX2”  
is displayed. This is the DMX addressing for the 2 Channel Mode.  
3. Please see pages 10-12 for DMX values and traits  
Operating Modes:  
Manual Dimmer:  
1. Plug the fixture in and press the MODE button until “XXX4” is dis-  
played.  
2. Use the UP and DOWN buttons to adjust the LED intensity.  
This onboard control mode is regulated by the max and minimun  
intenstiy settings. These settings are set in the DIM MAX SETTING  
and DIM MIN SETTING onboard control modes.  
Master-Slave Operation:  
This function will allows you to link units together to run in a Master-Slave  
mode. In Master-Slave operation one unit will act as the controlling unit  
and the others will react to the controlling units built-in programs. Any  
unit can act as a Master or as a Slave however, only one unit can be pro-  
grammed to act as the “Master.”  
Dim Max Setting:  
The Dim Max Setting will set the maximum dimness level for manual  
control and DMX mode.  
1. Plug the fixture in and press the MODE button until “XXX5” is dis-  
played.  
Master-Slave Connections and Settings:  
1. Daisy chain your units via the XLR connector on the rear of the unit.  
Use standard XLR microphone cables to link your units together.  
Remember that the Male XLR connector is the input and the Female  
XLR connector is the ouput. The first unit in the chain (master) will  
use the female XLR connector only. The last unit in the chain will use  
the male XLR connector only.  
2. Set the “Master” unit to your desired mode of operation.  
3. For the “Slave” unit(s), press the MODE button until “XXX3” is dis-  
played.  
2. Use the UP and DOWN buttons to adjust the maximum value of the  
LED dimmer. The setting can be adjusted between 50-100%.  
Dim Min Setting:  
The Dim Min Setting will set the minimum dimness level for manual con-  
trol and DMX mode.  
1. Plug the fixture in and press the MODE button until “XXX6” is dis-  
played.  
2. Use the UP and DOWN buttons to adjust the minimum value of the  
4. Use the UP and DOWN buttons to adjust the address. The slave unit  
must be set to the same address as the Master unit.  
5. Connect the “Slave” unit or units and they will automatically start to  
follow the “Master.”  
LED dimmer. The setting can be adjusted between 0-30%.  
DMX Mode:  
Operating through a DMX controller gives the user the freedom to create  
their own programs tailored to their own individual needs. This function  
also allows you to use your fixtures as spot lights. The ELED Fresnel  
100WW has 2 DMX modes: 1 Channel mode and 2 Channel mode. See  
page 9 for each modes’ DMX traits. Remember the maximum and  
minimum dimness levels are set in the Dim Max & Dim Min Settting  
menus.  
1. This function will allow you to control each individual fixture’s traits  
with a standard DMX 512 controller such as the Elation® Show  
Designer™ or the Elation® DMX Operator™.  
2. To run your fixture in DMX mode, plug in the fixture via the XLR con-  
nections to any standard DMX controller. Select your desired DMX  
mode, and then press the UP or DOWN buttons to adjust the DMX  
address. XXX = DMX Address  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELED Fresnel 100WW  
1 Channel Mode  
ELED Fresnel 100WW  
Cleaning  
Due to fog residue, smoke, and dust cleaning the internal and exter-  
nal optical lenses must be carried out periodically to optimize light  
output.  
Channel  
Value  
Function  
DIMMER 0% - 100%  
1
0 - 255  
ELED Fresnel 100WW  
2 Channel Mode  
1. Use normal glass cleaner and a soft cloth to wipe down the  
outside casing.  
2. Clean the external optics with glass cleaner and a soft cloth  
every 20 days.  
3. Always be sure to dry all parts completely before plugging  
the unit back in.  
Channel  
Value  
Function  
1
2
0 - 255  
0 - 255  
DIMMER 0% - 100%  
STROBING SLOW - FAST  
Cleaning frequency depends on the environment in which the fixture  
operates (i.e. smoke, fog residue, dust, dew).  
ELED Fresnel 100WW  
Trouble Shooting  
Listed below are a few common problems the user may encounter,  
with solutions.  
Unit not responding to DMX:  
1. Check that the DMX cables are connected properly and are  
wired correctly (pin 3 is “hot”; on some other DMX devices  
pin 2 may be ‘hot’). Also, check that all cables are connected  
to the right connectors; it does matter which way the inputs  
and outputs are connected.  
Unit does not respond to sound:  
1. Quiet or high pitched sounds will not activate the unit.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELED Fresnel 100WW  
Warranty  
ELED Fresnel 100WW  
Specifications  
2-YEAR LIMITED WARRANTY  
ELED Fresnel 100WW  
SPECIFICATIONS:  
Model:  
A. Elation Professionals® hereby warrants, to the original purchaser, Elation Profes-  
sionals® products to be free of manufacturing defects in material and workmanship  
for a period of two years (730 days) from the date of purchase. This warranty shall be  
valid only if the product is purchased within the United States of America, including  
possessions and territories. It is the owner’s responsibility to establish the date and  
place of purchase by acceptable evidence, at the time service is sought.  
Working Position:  
Voltage:  
Any safe working position  
100V ~ 240V/47~63Hz  
1 x 100W LED  
LED’s:  
B. For warranty service, send the product only to the Elation Professionals® factory.  
All shipping charges must be pre-paid. If the requested repairs or service (including  
parts replacement) are within the terms of this warranty, Elation Professionals® will  
pay return shipping charges only to a designated point within the United States. If the  
entire instrument is sent, it must be shipped in its original package. No accessories  
should be shipped with the product. If any accessories are shipped with the product,  
Elation Professionals® shall have no liability whatsoever for loss of or damage to any  
such accessories, nor for the safe return thereof.  
Power Consumption:  
Fuse:  
140W  
4 Amp  
Weight:  
11.6lbs./ 5.3Kgs.  
14.5” (L) x 9.84” (W) x 14.5” (H)  
White  
Dimensions:  
Colors:  
DMX Channels:  
2 DMX Modes: 1 Channel Mode &  
2 Channel Mode  
2 Year (730 days)  
C. This warranty is void if the serial number has been altered or removed; if the prod-  
uct is modified in any manner which Elation Professionals® concludes, after inspec-  
tion, affects the reliability of the product; if the product has been repaired or serviced  
by anyone other than the Elation Professionals® factory unless prior written authori-  
zation was issued to purchaser by Elation Professionals®; if the product is damaged  
because not properly maintained as set forth in the User Manual.  
Warranty:  
Please Note: Specifications and improvements in the design of  
this unit and this manual are subject to change without any prior  
written notice.  
D. This is not a service contract, and this warranty does not include maintenance,  
cleaning or periodic check-up. During the period specified above, Elation Profession-  
als® will replace defective parts at its expense, and will absorb all expenses for war-  
ranty service and repair labor by reason of defects in material or workmanship. The  
sole responsibility of Elation Professionals® under this warranty shall be limited to the  
repair of the product, or replacement thereof, including parts, at the sole discretion  
of Elation Professionals®. All products covered by this warranty were manufactured  
after January 1, 1990, and bear identifying marks to that effect.  
E. Elation Professionals® reserves the right to make changes in design and/or  
improvements upon its products without any obligation to include these changes in  
any products theretofore manufactured.  
F. No warranty, whether expressed or implied, is given or made with respect to any  
accessory supplied with products described above. Except to the extent prohibited  
by applicable law, all implied warranties made by Elation Professionals® in connec-  
tion with this product, including warranties of merchantability or fitness, are limited in  
duration to the warranty period set forth above. And no warranties, whether expressed  
or implied, including warranties of merchantability or fitness, shall apply to this prod-  
uct after said period has expired. The consumer’s and or Dealer’s sole remedy shall  
be such repair or replacement as is expressly provided above; and under no circum-  
stances shall Elation Professionals® be liable for any loss or damage, direct or conse-  
quential, arising out of the use of, or inability to use, this product.  
©Elation Professionals®  
A Division of the AmericanDJ® Group of Companies  
World Headquarters:  
G. This warranty is the only written warranty applicable to Elation Professionals®  
Products and supersedes all prior warranties and written descriptions of warranty  
terms and conditions heretofore published.  
6122 S. Eastern Ave. Los Angeles, CA 90040 USA  
Tel: 323-582-3322 Fax: 323-832-9142  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Brush Cutter PAS 2100 TYPE 1E User Manual
Eicon Networks Network Card DIVA T A ISDN Modem User Manual
Euro Pro Pressure Washer VPW38H User Manual
Exmark Lawn Mower Lazer Z AS User Manual
Fellowes Paper Shredder H 5C User Manual
FMI Indoor Fireplace ES401 User Manual
Frigidaire Microwave Oven FFMV152CLB User Manual
Generac Power Systems Portable Generator 009600 4 User Manual
GE Range 164D3333P185 1 User Manual
Glen Dimplex Home Appliances Ltd Cooktop 121R User Manual