Ei Electronics Smoke Alarm Ei100C User Manual

9V BATTERY POWERED  
Model Ei 100C Ionisation  
High sensitivity responds to all standard fires  
Dual Ionization chamber - quick response fast  
flaming fires  
Battery powered 9V supplied)  
Interconnect up to 12 other alarms  
Needs no wiring  
Missing battery indicator  
Low battery warning  
Built in sounder  
Test button  
Kitemarked to BS EN 14604:2005  
Product Description  
Operation  
The Ei100C is an Ionisation Smoke Alarm that runs on a  
9V alkaline battery (supplied with the alarm).  
Interconnect up to 12 other alarms (9V ionisation,  
optical or heat) when one senses smoke, all alarm.  
Helps ensure warning will be heard throughout the  
house  
The smoke detector will activate the built in sounder  
upon sensing smoke particles  
Ionisation smoke alarms operate on the principle that  
electrical current flowing between electrodes in an  
ionization chamber is reduced when smoke particles  
enter.  
The smoke detector will automatically reset itself  
and silence the sounder when smoke particles are  
no longer present in the sensing chamber  
Ionisation technology gives a rapid response to fast  
flaming fires  
The Ei100C is easily installed and comes supplied with  
all necessary screw fixings.  
The built in sounder will provide a minimum sound  
output of 85dB at 3m  
The Ei100C is fitted with a warning flag that pops up  
when the battery is removed. This prevents the cover  
from closing when there is no battery fitted to the unit.  
When the battery is being installed or changed, this flag  
must be held down while gently pushing the battery into  
the battery holder.  
The smoke detector has a built in warning flag to  
prevent installation of the detector without a battery  
fitted  
The “Test” button will perform a self test and sound  
the horn (it may take up to 10 seconds)  
When the battery is first connected, the alarm may sound  
for 2-3 seconds this is normal and means that the  
battery is connected correctly  
The smoke detector will emit a beep every 40  
seconds to indicate that the battery back up is  
depleted and needs replacing  
Shannon Free Zone, Shannon, Co. Clare, Ireland.  
Ph.+353 61 471277 Fx.+353 61 471053  
E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice.  
Ei100C DataSht RevB  
Download from Www.Somanuals.com. All Manuals Search And Download.  

EdgeStar Ice Maker IB450SS User Manual
Excalibur electronic Clock SF23 User Manual
Extron electronic Switch FOX 3G DVC User Manual
Fisher Price Baby Toy W4123 User Manual
Fisher Price Stroller FP3456 User Manual
Fluke Thermometer 189 User Manual
Frigidaire Burner Side Burner User Manual
Frigidaire Cooktop FGGC3047Q S W B User Manual
Fujitsu Network Card FMC 16FX FAMILY User Manual
Gardena Trimmer THS 42 User Manual