EXFO Photonic Solutions Div Network Card IQS 12001B User Manual

CABLE ASSEMBLY AND COMPONENT  
TEST SYSTEM  
IQS-12001B  
R&D AND MANUFACTURING—OPTICAL  
Provides the most accurate insertion loss  
and reflectance measurements on the market  
for components and cable assemblies  
High-sensitivity, mandrel-free reflectance measurements down to  
–75 dB, meeting requirements for the most demanding FTTH applications  
Simultaneous measurement on four wavelength (1310, 1490, 1550  
and 1625 nm)  
Open architecture allows for customizable controls and remote  
configuration  
Compatible with simplex, duplex, multifiber, bundle, hybrid and fanout  
cable assemblies, as well as PLC splitters and planar arrays  
Platform compatibility  
IQS-600 Integrated Qualification System  
IQS-500 Intelligent Test System  
Telecom Test and Measurement  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IQS-12001B  
Cable Assembly and Component Test System  
System overview  
The IQS-12001B system features a loss test module (IQS-3250/3250B), optional optical switches and a software package that  
integrates and manages test sequences, the database and its results, as well as the peripherals such as bar code reader, label printers  
and foot switches used in production environments.  
1
2
Loss and reflectance measurements  
1
2
The IQS-3250/3250B Loss Test Module is based on advanced time-domain technology with a wide-aperture integrating cavity  
detector. The module’s internal monitoring channel ensures IL measurement accuracy while its internal reflectance reference  
significantly improves multimode and singlemode reflectance measurement performance; in singlemode assembly, it also accounts  
for the effects of Rayleigh backscattering in each measurement. Combined with EXFO’s advanced detection electronics and  
algorithms, the IQS-3250/3250B provides highly accurate mandrel-free reflectance measurements for even the most difficult-to-  
test APC connectors.  
Customizable modular architecture  
The IQS-12001B’s unique architecture allows you to add and remove modules to meet your testing needs. Mix and match  
different wavelength combinations, test singlemode and multimode cable assemblies, and add switches to convert your simplex  
configuration into a multifiber test system—thanks to the system’s unified software and powerful database, which protect your  
valuable production data.  
Supported accessories  
Label printer  
Bar code reader  
Foot switch  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IQS-12001B  
Cable Assembly and Component Test System  
User-Friendly Turnkey Software  
Comprehensive software  
On-screen instructions with graphical display of the  
connections  
IL and reflectance live monitoring in the main window  
Display of the last 100 results in a real-time chart  
Post-processing made easy  
Integrated, centralized database to save and manage  
results, and to generate reports and statistics  
Direct integration with bar code reader, foot switch  
and label printers  
Label printing utility, allowing users to design their  
own labels  
Customize it to fit your needs  
The IQS-12001B comes with DLL interfaces that enable you  
to create your own applications and remotely control your  
system. These system-level commands ensure smooth,  
efficient application creation without compromising the  
system’s measurement accuracy and speed. A simple Visual  
Basic demo is provided to help you get started with your own  
EXFO GUI  
application.  
Your SW application  
EXFO DLL control  
IQS-12001B Cable  
Assembly and  
Component Test System  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IQS-12001B  
Cable Assembly and Component Test System  
Best Performance in the Industry  
Test faster, increase your productivity  
Cable assembly testing  
Insertion loss and reflectance measurements on four wavelengths in  
ten seconds flat  
Mandrel-free reflectance measurement  
Capability to measure singlemode reflectance (discreet reflection)  
down to –75 dB, meeting the requirements of even the most  
demanding FTTH applications  
Component testing (singlemode only, through DLL interfaces)  
One sequence for insertion loss, reflectance, optical return loss and  
fiber length measurements for all wavelengths  
Mandrel-free measurement with one-meter resolution  
Accurate, repeatable and flexible  
EXFO has developed an innovative detector assembly for the IQS-12001B.  
Using wide-aperture integrating cavity packaging, the detector has many  
properties that make it ideal for interconnect testing. The wide aperture allows  
it to be used for simplex and multifiber connectors. Because it uses integrating  
cavity technology, connector alignment is less critical and polarization  
dependence is negligible. The end result is increased accuracy, repeatability  
and flexibility.  
Combining an integrating cavity with a detector and the right diameter input  
port provides a major advantage: power measurements are independent of the  
fiber’s numerical aperture, ferrule polish (PC or APC) and alignment, since the  
cavity scatters all incident light, with the same average power reaching the  
detector. Integrating cavity technology is a built-in feature of the two detectors  
used with the IQS-12001B Cable Assembly and Component Test System,  
the IQS-3250/3250B Loss Test Module and the IQS-9403 Loss Meter.  
Integrating cavity diagram.  
Calibration verification tool  
Reflectance referencing can also be achieved through the CKT-30 Singlemode Reflectance Reference module. Using the IQS-12001B’s  
reflectance verification wizard, you can perform a step-by-step verification of your system’s reflectance calibration. As long as it is within  
0.5 dB to that of the CKT-30, you know your system meets calibration specifications and don’t need to send it to EXFO for verification—  
avoiding unnecessary downtime.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IQS-12001B  
Cable Assembly and Component Test System  
Configure Your System for Optimal Performance  
The IQS-12001B Cable Assembly Test System is available in two configurations: Standard and High-Throughput. The Standard  
configuration includes only the minimal hardware necessary to get the job done. It keeps costs in check, while providing fast and  
accurate measurements in a user-friendly format.  
The High-Throughput (HT) configuration minimizes the handling required, reducing the overall testing time and increasing the  
productivity. This mode of operation is particularly well-suited to hybrid assembly and/or multiwavelength testing. The IQS-12001B can  
accommodate additional switch ports and loss meters, enabling hybrid assemblies to be tested in one sequence. External optical  
switches can be controlled by the IQS-12001B GPIB interface for test applications requiring more than 32 channels.  
The IQS-12001B lets you dedicate switch ports to specific connector types, which avoids having to disconnect the launch fiber, saving  
valuable setup time. For example, with a 1x32 switch, you can dedicate ports 1 to 24 to MTP connectors (male and female), ports 25  
to 28 to MT-RJ connectors (male and female), and still have room for FC, ST, SC and MU connectors. Depending on the device under  
test (DUT), the system uses the appropriate port.  
Standard Configuration  
High-Troughput Configuration  
Simplex  
Simplex  
MTJ1  
MTJ1  
OUT  
OUT  
FC  
FC  
SC  
MTJ2  
IN  
IN  
IN  
IQS-9100  
IQS-3250  
IQS-9403  
Loss Meter  
IQS-3250  
1X2  
Optical Switch  
Loss Test Module  
Loss Test Module  
Basic configuration for testing simplex  
and multifiber bundles.  
With an additional loss meter and a 1x2 optical switch, hybrid  
simplex assemblies can be efficiently tested. The two master test  
jumpers and detectors are configured for the different connectors  
of the hybrid assembly.  
Multifiber Connector  
Multifiber Connector  
MTJ1  
MTJ1  
OUT  
OUT  
MTRJ  
MTRJ  
Male  
IN  
IN  
MTJ2  
Female  
IQS-9100  
IQS-9100  
1X2  
Optical Switch  
IQS-3250  
IQS-3250  
Loss Test Module  
1X2  
Loss Test Module  
Optical Switch  
Basic configuration for testing multifiber  
connectors such as MTP and MT-RJ.  
By doubling the number of switch ports, the system can be  
configured to accept both male and female multifiber connectors.  
The end result is faster and simpler testing in a single sequence.  
Standard and High-Throughput configurations are also available for testing bundle, duplex and multifiber to fanout assemblies.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IQS-12001B  
Cable Assembly and Component Test System  
a
SPECIFICATIONS  
Singlemode b (1310/1550 nm)  
Singlemode b (1490/1625 nm)  
Multimode c  
Testing time d (s)  
< 6  
< 6  
< 6  
Cable assembly length (m)  
1.8 to 1500  
1.8 to 1500  
1.8 to 500  
Insertion loss measurement uncertainty  
0.03 e  
0.03 e  
0.07 f  
< 0.005  
−30 to −75  
Insertion loss measurement stability g (dB)  
< 0.005  
−30 to −75  
< 0.028  
Reflectance range (dB)  
−10 to −50  
Reflectance measurement uncertainty (dB)  
1 (−30 to −70)  
1 (−30 to −70)  
1.2 (−10 to –30)  
1.5 (−30 to –40)  
2.2/ 1.7 (−70 to −75)  
1.7 (−70 to −75)  
1.6 (−40 to –43)  
2.9 (−43 to –50)  
0.2 (−10 to –30)  
0.4 (−30 to –40)  
0.6 (−40 to –43)  
1.8 (−43 to –50)  
Reflectance measurement repeatability h (dB)  
0.1 (−30 to −65)  
0.2 (−65 to −70)  
0.4 (−70 to −75)  
0.1 (−30 to −65)  
0.2 (−65 to −70)  
0.5 (−70 to −75)  
Wavelengths (nm)  
Output channels  
Test method  
1310/1550  
Up to 32 channels  
End-to-end/bidirectional  
1490/1625  
Up to 32 channels  
End-to-end/bidirectional  
850/1300  
Up to 32 channels  
End-to-end/bidirectional  
Notes  
a. Calculated and measured with the following considerations:  
• Based on recommended procedure for ORL measurements  
• The FOA-300 series’ uncertainty is included in all uncertainty values  
• Although tests are possible with other fiber-optic adapters, these specifications are only valid with the FOA-300 series  
• Cable assemblies < 1.8 m can be tested using a non-reflective termination  
• With 15 minute warm-up time  
b. For SMF-28 fiber. At 23 ºC 1 ºC in High-Sensitivity Reflectance mode with no switch.  
c. At 850 nm and 1300 nm. For 62.5/125 µm fibers. At 23 °C 1 °C, after 30 minutes warmup. Switch module connectorized with FC/PC connectors.  
Uncertainty due to launching conditions not included.  
d. Calculation and storage time for simplex, dual-wavelength IL/reflectance end-to-end measurements (Standard Reflectance Sensitivity mode, 500 meter range);  
does not include referencing and connection time.  
e. For simplex measurements using FOA-322 adapter. Uncertainty for MTP to MTP, MT-RJ to MT-RJ, MTP to fanout and MT-RJ to fanout is 0.06 dB  
(reported with a level of confidence of 95 %). This does not include uncertainties due to connector, connector adapter or switch PDL.  
f. For simplex measurement using FOA-322 adapter. Uncertainty for MTP to MTP, MT-RJ to MT-RJ, MTP to fanout and MT-RJ to fanout is 0.08 dB  
(calculated for a level of confidence of 95 %). Does not include uncertainties due to connector, connector adapter or uncertainties due to mode dependence of the switch.  
g. For a stable connection, over 15 minutes, at constant temperature.  
h. For a stable connection, over 10 measurements.  
GENERAL SPECIFICATIONS  
Communication interfaces  
General-purpose interface bus (GPIB)  
Ethernet (10/100 Base-T)  
RS-232  
Temperature  
Operating  
Storage  
0 °C to 40 °C  
−40 °C to 60 °C  
(32 °F to 104 °F)  
(−40 °F to 140 °F)  
Relative humidity  
80 % maximum, non-condensing  
Laser Safety  
21 CFR 1040.10  
CLASS 1 LASER PRODUCT  
CLASS 1 LASER PRODUCT  
IEC 60825-1:2001  
Standard Accessories  
Expansion units as required, user guide, certificate of compliance, custom report, label generator, IQS-12001B software and EUI-89 FC narrow key connector.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IQS-12001B  
Cable Assembly and Component Test System  
ORDERING INFORMATION  
IQS-12001B-XX-XX-X-XX-XX-XX-XX-XX-XX-XX  
Additional Loss Meter  
Model  
00 = Without additional loss meter  
PM01 = With one additional loss meter  
IQS-12001B-05-S5-B = IQS-605P, 1310/1550 nm, IL/RL, optional switch 9/125 µm, APC connector  
IQS-12001B-05-S6-B = IQS-605P, 1490/1625 nm, IL/RL, optional switch 9/125 µm, APC connector  
IQS-12001B-05-S7-B = IQS-605P, 1490 nm, IL/RL, optional switch 9/125 µm, APC connector  
IQS-12001B-05-S8-B = IQS-605P, 1310/1550 and 1490/1625 nm, IL/RL with 1x2 optical switch,  
optional switch 9/125 µm, APC connector  
IQS-12001B-10-S5-B = IQS-610P, 1310/1550 nm, IL/RL, optional switch 9/125 µm, APC connector  
IQS-12001B-10-S6-B = IQS-610P, 1490/1625 nm, IL/RL, optional switch 9/125 µm, APC connector  
IQS-12001B-10-S7-B = IQS-610P, 1490 nm, IL/RL, optional switch 9/125 µm, APC connector  
IQS-12001B-10-S8-B = IQS-610P, 1310/1550 and 1490/1625 nm, IL/RL with 1x2 optical switch,  
optional switch 9/125 µm, APC connector  
IQS-12001B-05-S1-C = IQS-605P, 850/1300 nm, IL only, optional switch 50/125 µm, PC connector  
IQS-12001B-05-S1-D = IQS-605P, 850/1300 nm, IL only, optional switch 62.5/125 µm, PC connector  
IQS-12001B-05-S2-C = IQS-605P, 850/1300 nm, IL/RL, optional switch 50/125 µm, PC connector  
IQS-12001B-05-S2-D = IQS-605P, 850/1300 nm, IL/RL, optional switch 62.5/125 µm, PC connector  
IQS-12001B-10-S1-C = IQS-610P, 850/1300 nm, IL only, optional switch 50/125 µm, PC connector  
IQS-12001B-10-S1-D = IQS-610P, 850/1300 nm, IL only, optional switch 62.5/125 µm, PC connector  
IQS-12001B-10-S2-C = IQS-610P, 850/1300 nm, IL/RL, optional switch 50/125 µm, PC connector  
IQS-12001B-10-S2-D = IQS-610P, 850/1300 nm, IL/RL, optional switch 62.5/125 µm, PC connector  
Connector Adapter  
FOA-316 = Ultra-low reflection SMA 906  
FOA-322 = Ultra-low reflection FC  
FOA-328 = Ultra-low reflection DIN 47256  
FOA-332 = Ultra-low reflection ST  
FOA-340 = Ultra-low reflection HMS-0, HFS-3  
FOA-354 = Ultra-low reflection SC  
FOA-376 = Ultra-low reflection HMS, HFS-10/AG  
FOA-384 = Ultra-low reflection HMS-10/HP, HFS  
FOA-392 = Ultra-low reflection MTP  
FOA-393 = Ultra-low reflection MT-RJ  
FOA-396 = Ultra-low reflection E-2000  
FOA-397 = Ultra-low reflection LX.5  
FOA-398 = Ultra-low reflection LC  
FOA-399 = Ultra-low reflection MU  
FOA-3000 = Adapter for BFA-3000  
Hard Disk  
00 = Standard hard disk  
RHD = RAID 1 second hard drive  
Reflectance Reference  
00 = Without reflectance reference  
CKT-30 = With reflectance reference singlemode  
Channel Count  
00 = Without switch  
1-02 = 1x2 switch  
1-04 = 1x4 switch  
1-12 = 1x12 switch  
1-24 = 1x24 switch  
1-32 = 1x32 switch  
GPIB Card  
00 = Without GPIB card  
I3 = GPIB master slave/card  
Short Component  
00 = Without short component measurement option  
SCM = With short component measurement option  
- Singlemode switch with FC/APC connector  
- Multimode switch with FC/PC connector  
- Other connectors available: contact EXFO for special order  
Example: IQS-12001B-10-S5-B-RHD-FOA-322-I3-SCM  
Optional Accessories  
FIP-400-USB2-DUAL: Video fiber inspection probe with USB 2.0 converter and software.  
FOA-U12: Universal 1.25 mm ferrule  
FOA-U25: Universal 2.5 mm ferrule  
EXFO Corporate Headquarters > 400 Godin Avenue, Quebec City (Quebec) G1M 2K2 CANADA Tel.: 1 418 683-0211 Fax: 1 418 683-2170 [email protected]  
Toll-free: 1 800 663-3936 (USA and Canada) www.EXFO.com  
Fax: 1 972 836-0164  
EXFO America  
EXFO Europe  
EXFO Asia  
3701 Plano Parkway, Suite 160  
Plano, TX 75075 USA  
Chandlers Ford, Hampshire S053 4SE ENGLAND  
SINGAPORE 169876  
Tel.: 1 800 663-3936  
Tel.: +44 2380 246810  
Tel.: +65 6333 8241  
Omega Enterprise Park, Electron Way  
151 Chin Swee Road, #03-29 Manhattan House  
No. 88 Fuhua, First Road, Central Tower, Room 801  
Futian District  
Fax: +44 2380 246801  
Fax: +65 6333 8242  
Fax: +86 (755) 8203 2306  
EXFO China  
Shenzhen 518048 P. R. CHINA  
Tel.: +86 (755) 8203 2300  
Beijing New Century Hotel Office Tower, Room 1754-1755  
No. 6 Southern Capital Gym Road  
Beijing 100044 P. R. CHINA  
Tel.: +86 (10) 6849 2738  
Fax: +86 (10) 6849 2662  
EXFO is certified ISO 9001 and attests to the quality of these products. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference  
received, including interference that may cause undesired operation. EXFO has made every effort to ensure that the information contained in this specification sheet is accurate. However, we accept no responsibility for any errors or omissions, and we reserve the right to modify  
design, characteristics and products at any time without obligation. Units of measurement in this document conform to SI standards and practices. In addition, all of EXFO’s manufactured products are compliant with the European Union’s WEEE directive. For more information, please  
visit www.EXFO.com/recycle. Contact EXFO for prices and availability or to obtain the phone number of your local EXFO distributor.  
For the most recent version of this spec sheet, please go to the EXFO website at http://www.EXFO.com/specs  
In case of discrepancy, the Web version takes precedence over any printed literature.  
SPIQS12001B.7AN  
© 2008 EXFO Electro-Optical Engineering Inc. All rights reserved.  
Printed in Canada 08/02  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Tiller TC 2100 User Manual
Everpure Water Dispenser OW200L User Manual
Fender DJ Equipment PX 2208 User Manual
FMI Gas Heater FVF18PW User Manual
Focal Car Speaker 33 V2 User Manual
Frigidaire Range 316000291 9902 User Manual
Fujitsu Scanner fi 5950 User Manual
Garland Oven All Purpose Oven User Manual
GE Air Conditioner AS_05 User Manual
Gianni Industries Door EB 260 User Manual