OWNER’S MANUAL
PS220
SEQUENCING, 2-CHANNEL
REMOTE-CONTROL FLUSH-MOUNT WALL OUTLET
PS220 SPECIAL FEATURES:
• Power 120 VAC 50/60Hz, 20 amps total current available,
and 2400 watts total power.
Air Vents
PS220
• Sequences 2 outlets - CH 1 and CH 2
TWO CHANNEL
CH 1
SEQUENCER
• Programmable delay between CH 1 and CH 2 turn off of
1, 5, 10 and 30 seconds
• Remotely turn “ON” or “OFF” the outlets. A remote LED
indicator can be used to show the PS220 activity
ETA SYSTEMS
LED Indicators
A Creative Light And Sound Company
120 VAC
50/60 HZ
20 AMPS
TOTAL
RESET
PROTECTION ON
• Daisy chain capabilities using a communications port
POWER
SEQUENCING
• Manual reset of the microprocessor
• Spike and surge protection on all three legs of incoming
120V 50/60Hz, single-phase electrical power
CH 1
CH 2
Fan
CH 2
• Surge protection is active when the green
(PROTECTION ON) LED is lit.
• Certified to UL1472 and CSA C22.2 No.184.1 standards
PS220: 3-gang outlet box, 67.3 cu.in.
New construction outlet box
SEQUENCING: When activated, the PS220 CH1 outlet turns “ON”, then CH2 outlet turns “ON”. When deactivated the
PS220 CH2 turns “OFF”, then CH1 turns “OFF.”
DELAY: A 1, 5, 10 or 30 second time-delay is available between CH1 and CH 2, when turning “ON” or “OFF.” To adjust
time delays, place the jumper on J100 to the appropriate location. See diagram below.
RESET: Use the push button switch for resetting the unit’s microprocessor. The Green “POWER ON” LED goes off for
1 second during a manual rest. Use the recommended screwdriver to depress the reset button.
UNIT OPERATION: A Green “POWER ON” LED will indicate when power is present to the unit. (The Green “POWER ON”
LED will go off for 1 second during power up, to indicate the microprocessor is ready.) Green “POWER ON” LED
will flash while the unit is sequencing on or off, or when another sequencer that is daisy chained in line is
sequencing on or off. The two Red CH 1 and CH 2 LED indicators will light when CH1 or CH2 of the receptacle
is turned on.
DAISY CHAIN: The PS220 is daisy chained to any other PS220 or 4-channel ETA sequencing unit.
Master Unit: connection to the outputs only (terminals 6 & 7). This output connection is then connected to an
input of another ETA sequencing unit.
Slave Unit: connection to the inputs only (terminals 4 & 5). This input connection comes from the output of
another ETA sequencing unit.
In-line Unit: this unit has connections to both input and output.
Note: the above-mentioned input and output connections can be connected without regard to polarity.
REMOTE
WALL
PLATE
PS220
2 CH SEQ
2 OR 4 CHANNEL
SEQUENCER
2 OR 4 CHANNEL
SEQUENCER
PS220
SEQUENCER
BASE RELAY
INSTALLATION
OPTION
2 or 3
WIRES
PS220
TWO CHANNEL
SEQUENCER
CH
1
2 WIRES
IN
PS220
PD11SP
PD420VS
2 WIRES
OUT
PS220
PD11SP
PD420VS
ETA SYSTEMS
Creative Light And Sound Company
A
120 VAC
50/60 HZ
20 AMPS
TOTAL
RESET
PROTECTION ON
POWER
SEQUENCING
CH
CH
1
2
CH
2
OUT
IN
L.E.D. AND
SWITCH
*NOTE: Internal terminal block for
hook-up of 3-wire remote and
comunications, linking ports
This is the PC board located inside insulating barrier
1PCB-086
You can change the delay by moving the jumper at J100.
TERMINAL BLOCK
CONNECTION
J100
30 SEC
1. Switch (+)
2. Switch & LED (-) Common
3. LED (+) Indicator
4. Input
10 SEC
5 SEC
1 SEC
Using the recommended wire, connect to the terminal
block using one of the following two options.
Recommended Wire: Size 24-22 GA
Max. Wire Length 1000 FT.
1
2
3
4
5
6
7
5. Input
Screw Torque: .5-.6 Nm
6. Output
Screwdriver: Flatblade .6 x 3.5 x 100mm
7. Output
Download from Www.Somanuals.com. All Manuals Search And Download.
|