INSTRUCTION MANUAL
2HP & 2.5HP
30 Litre & 40 Litre
Air Compressors
Warning!
Do not switch on
for the first time
without first
filling with oil.
• Melbourne • Perth • Auckland • Hong Kong • Shanghai
AC30G/AC40G
050812 ED5 JJ
• Taipei • New York • Verona • London • Paris
AC30G_AC40G
1
12/8/05, 4:48 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Warning labels explained
On the tank of your air compressor you will notice various
warnings about the operation of the compressor. These
warnings and the procedures associated with them are
explained fully in this manual on the following pages.
Please take note of these. They are important for your
safety and that of others in the vicinity.
Warning!
Do not switch on
for the first time
without first
filling with oil.
Warning!
Oil Level
Tank Drain
Air InletŁ
Filter
When filter becomes
dirty or oily, replace
cartridge. Refer to
instruction manual.
Unit starts
automatically.
Switch off power supply,
remove plug & relieve
air pressure prior to
commencing service
tasks.
Keep oil level as shown:
To prevent build-up of
condensation, open
drain cock daily
Use only oil grade
specified in instruction
manual.
Operating
Danger!
Warning!
Warning!
Read instruction manual
prior to starting unit.
High voltage used on
this equipment. Switch
off power supply &
remove plug from mains
before removing any
covers. Ensure mains
outlet is adequately
rated for this unit.
Air discharged from
this unit is not
suitable for human
consumption.
Test the safety relief
valve daily.
This equipment
operates from
AC mains only.
Refer the instruction
manual.
3
AC30G_AC40G
3
12/8/05, 4:48 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Description of symbols
Dear Customer
The rating plate on your tool may show symbols. These
represent important information about the product or
instructions on its use.
If you require any help with your product, whether it
is a Warranty claim, spare part or user information,
please phone our Help Line for an immediate response.
Phone 1300 880 001 in Australia or 0800 445 721 in
New Zealand.
Wear hearing protection.
Wear eye protection.
Wear breathing protection.
Introduction
Conforms to relevant standards for
electromagnetic compatibility.
Your new GMC power tool will more than satisfy your
expectations. It has been manufactured under stringent
GMC Quality Standards to meet superior performance
criteria.
You will find your new tool easy and safe to operate,
and, with proper care, it will give you many years of
dependable service.
Specifications
AC30G
AC40G
2.5HP/1.8kW
Power:
2HP/1.5kW
Voltage:
230–240Vac ~ 50Hz
CAUTION. Carefully read through this entire Instruction
Manual before using your new GMC Power Tool. Take
special care to heed the Cautions and Warnings.
Your GMC power tool has many features that will make
your job faster and easier. Safety, performance, and
dependability have been given top priority in the
development of this tool, making it easy to maintain
and operate.
No load speed:
Current:
2850min-1
7A
8A
Maximum Output:
Discharge pressure:
Tank capacity:
Air outlet size:
Dimensions:
0.1m3/min
0.8MPa (115psi)
30 litres 40 litres
6.35mm (1/4”)
680mm x 290mm 684mm x 304mm
x 635mm
x 705mm
32kg
Environmental protection
Net weight:
Cut-in pressure
(factory set):
Cut-out pressure
(factory set):
27kg
Recycle unwanted materials instead of
disposing of them as waste. All tools, hoses
and packaging should be sorted, taken to
the local recycling centre and disposed of
in an environmentally safe way.
0.6MPa (85psi)
0.8MPa (115psi)
Maximum
output pressure:
0.8MPa (115psi)
Free air delivery: 152 l/min
(5.4 CFM)
174l/min
(6.1 CFM)
Pump
displacement:
202 l/min
(7.1CFM)
228 l/min
(8CFM)
4
AC30G_AC40G
4
12/8/05, 4:48 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Dress correctly. Do not wear loose clothing or
jewellery. They can be caught in moving parts. Rubber
gloves and non-slip footwear are recommended when
working outdoors. If you have long hair, wear a
protective hair covering.
8. Use safety accessories. Safety glasses and earmuffs
should always be worn. A face or dust mask is also
required if the sanding operation creates dust.
9. Do not abuse the power cord. Never pull the cord to
disconnect the tool from the power point. Keep the
cord away from heat, oil and sharp edges.
10. Secure the work piece. Use clamps or a vice to hold
the work piece. It is safer than using your hand and
frees both hands to operate the tool.
General safety instructions
To use this tool properly, you must observe the safety
regulations, the assembly instructions and the operating
instructions to be found in this Manual. All persons who
use and service the machine have to be acquainted with
this Manual and must be informed about its potential
hazards. Children and infirm people must not use this
tool. Children should be supervised at all times if they
are in the area in which the tool is being used. It is
also imperative that you observe the accident prevention
regulations in force in your area. The same applies for
general rules of occupational health and safety.
Warning. When using power tools, basic safety
precautions should always be taken to reduce the risk of
fire, electric shock and personal injury. Also, please read
and heed the advice given in the additional important
safety instructions.
11. Do not overreach. Keep your footing secure and
balanced at all times.
12. Look after your tools. Keep tools sharp and clean for
better and safer performance. Follow the instructions
regarding lubrication and accessory changes. Inspect
tool cords periodically and, if damaged, have them
repaired by an authorised service facility. Inspect
extension cords periodically and replace them if
damaged. Keep tool handles dry, clean and free from
oil and grease.
13. Disconnect idle tools. Switch off the power and
disconnect the plug from the power point before
servicing, when changing accessories and when the
tool is not in use.
1. Keep the work area clean and tidy. Cluttered work
areas and benches invite accidents and injury.
2. Consider the environment in which you are working.
Do not use power tools in damp or wet locations.
Keep the work area well lit. Do not expose power tools
to rain. Do not use power tools in the presence of
flammable liquids or gases.
3. Keep visitors away from the work area. All visitors
and onlookers, especially children and infirm persons,
should be kept well away from where you are working.
Do not let others in the vicinity make contact with the
tool or extension cord.
14. Remove adjusting keys and wrenches. Check to see
that keys and adjusting wrenches are removed from
the tool before switching on.
4. Store tools safely. When not in use, tools should be
locked up out of reach.
5. Do not force the tool. The tool will do the job
better and safer working at the rate for which it was
designed.
6. Use the correct tool for the job. Do not force small
tools or attachments to do the job best handled by a
heavier duty tool. Never use a tool for a purpose for
which it was not intended.
15. Avoid unintentional starting. Always check that the
switch is in the OFF position before plugging in the
tool to the power supply. Do not carry a plugged in
tool with your finger on the switch.
16. Use outdoor rated extension cords. When a tool
is used outdoors, use only extension cords that are
intended for outdoor use and are so marked.
5
AC30G_AC40G
5
12/8/05, 4:48 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
• To reduce the risk of fire or explosion, never spray
flammable liquids in a confined area. It is normal for
the compressor motor and pressure switch to produce
sparks during use. If sparks come into contact with
petrol vapours or solvents, they may ignite the vapours
and cause a fire or explosion.
• Always operate the compressor in a well ventilated area.
Do not smoke while spraying. Do not spray where sparks
or flames are present. Keep the compressor as far away
from the spray area as possible.
• The solvents trichloroethane and methylene chloride can
chemically react with the aluminium used in some paint
spray guns and form an explosion. If these solvents are
used, ensure that only stainless steel spray equipment is
connected. The compressor is not affected by the use of
these solvents.
17. Stay alert. Watch what you are doing. Use common
sense. Do not operate a power tool when you are
tired.
18. Check for damaged parts. Before using a tool,
check that there are no damaged parts. If a part is
slightly damaged, carefully determine if it will operate
properly and perform its intended function. Check for
alignment of moving parts, binding of moving parts,
breakage of parts, proper mounting and any other
conditions that may affect the operation of the tool.
A part that is damaged should be properly repaired
or replaced by an authorised service facility, unless
otherwise indicated in this Instruction Manual.
Defective switches must be replaced by an authorised
service facility. Do not use a tool if the switch does
not turn the tool on and off correctly.
19. Guard against electric shock. Prevent body contact
with grounded objects such as water pipes, radiators,
cookers and refrigerator enclosures.
• Never directly inhale the compressed air produced by
a compressor and do not use it for charging breathing
tanks.
20. Use only approved parts. When servicing, use only
identical replacement parts. Use an authorised service
facility to fit replacement parts.
• Do not use welding equipment in close proximity to the
compressor. Do not weld anything to the air tank of the
compressor: this could dangerously weaken the tank and
will void the warranty.
• Do not use the compressor outdoors when it is raining
or on a wet surface; either situation could cause an
electric shock.
• Always shut off the compressor after use and before
servicing. Push the on/off knob down, wait for the
pressurised air to bleed from the tank from the release
valve and then remove the electrical plug from the
power supply.
• Check the maximum pressure rating of any tools or
accessories that you intend using with the compressor.
The output pressure of the air from the compressor must
be regulated so that it never exceeds the rated pressure
of the tool or accessory.
Additional safety rules for air compressors
Warning. Before connecting a tool to a power source
(mains switch power point receptacle, outlet, etc.) be sure
that the voltage supply is the same as that specified on
the nameplate of the tool. A power source with a voltage
greater than that specified for the tool can result in
serious injury to the user, as well as damage to the tool.
If in doubt, do not plug in the tool. Using a power source
with a voltage less than the nameplate rating is harmful
to the motor.
Always remove the plug from the mains socket before
making any adjustments or maintenance, including
renewing the lubricating oil.
6
AC30G_AC40G
6
12/8/05, 4:48 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
• To avoid the risk of burns and injury from moving parts,
do not operate the compressor with the safety shield
removed. Allow hot parts to cool before handling or
servicing.
• Be certain to read all the labels on the containers of
paint or other materials to be sprayed. Closely follow
all safety instructions. Use a respirator mask if there
is a chance that you might otherwise inhale the spray
material. Carefully check the effectiveness of any
respirator mask you intend using.
• Always wear safety goggles or glasses when using the
air compressor. Never point the nozzle of an accessory
towards any part of your body or towards another
person.
• Do not attempt to adjust the pressure switch or the
release valve located under the pressure switch cover.
• Drain the moisture from the tank daily. It will help
prevent corrosion.
• Pull the ring on the safety valve daily to ensure that
it operating properly and to clear any possible instruc-
tions.
• Keep the compressor at least 300mm from the nearest
wall to ensure adequate ventilation for cooling
purposes.
• Before transporting the compressor make sure that
the pressurised air is bled from the tank and that the
compressor is firmly secured.
• Always press the on/off button down to switch off the
compressor before switching off the power or removing
the power plug.
• Do not use the compressor without first checking the oil
level. It must be close to the red circle as viewed on the
oil gauge.
NOTE. The compressor is supplied empty of oil. It must be
filled with oil before first use.
• After using the compressor, switch off the on/off
button, disconnect the power supply and open the
outlet valve to release the pressure.
• Do not attempt to remove any part of the machine
whilst it is under pressure.
• Ensure that the lubricating oil is clean and that the oil
level is maintained at the correct level. Replace the oil
as indicated in the Maintenance section of this Manual.
• Use safety equipment including safety goggles or
shield, ear protection, breathing or respirator mask and
protective clothing.
Wear goggles.
Wear earmuffs.
Wear a breathing or respirator mask.
Never apply the outlet air of this compressor directly on to
any part of a person’s body. Do not attempt to block the
air outlet with your finger or any part of your body.
The tool must be used only for its prescribed purpose. Any
use other than those mentioned in this Manual will be
considered a case of misuse. The user and not the manu-
facturer shall be liable for any damage or injury resulting
from such cases of misuse.
• Protect the air hose and cordset from damage.
Inspect for weak or worn spots regularly and replace if
necessary.
• Do not use an extension cord with this product. Use
additional air hose instead of an extension cord to
prevent power loss and possible damage to the motor.
Use of an extension cord voids the warranty.
The manufacturer shall not be liable for any changes
made to the tool nor for any damage resulting from such
changes.
• After long working periods external metal parts could
be hot.
7
AC30G_AC40G
7
12/8/05, 4:48 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Even when the tool is used as prescribed it is not possible
to eliminate all residual risk factors. The following hazards
may arise in connection with the tool’s construction and
design:
• Damage to the lungs if an effective breathing mask is
not worn.
• Damage to hearing if effective earmuffs are not worn.
• Damage to the eyes if effective safety goggles or shield
are not worn.
Warning.
In the event that an air line is cut or broken, the air
supply must be turned off at the compressor. A broken air
line which is not supported is extremely dangerous and
can whip around very quickly, both with the capability of
striking people, and blowing foreign particles into the air.
Do not attempt to catch the air line but immediately keep
bystanders well clear and turn off the air supply to the
hose, turn off the compressor at the On / Off button, and
then remove the hose from the compressor.
Contents of carton
• 400ml of oil in a sealed container
• 2 Wheel assemblies
( 2 each of axle pins, flat washers,
split washers, nuts, wheel caps)
• Air filter
• Rubber feet assemblies
(30L - 1, 40L - 2)
Additional contents for the 40L
• Handle with attaching screws
(grub screws in plastic bag)
• Allen key
8
AC30G_AC40G
8
12/8/05, 4:48 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Know your product
1.Handle
15
13
2.Pressure switch cover
3.On/off switch
4.Tank pressure gauge
5.Regulating knob
6.Regulated outlet valve
7.Regulated outlet
pressure gauge
3
2
5
18
8.Safety valve
4
6
9. Non-return valve
10. Drain cock
11. Air tank
16
7
9
12. Wheel (x 2)
13. Safety shield
14. Oil filling cap
15. Air filter assembly
16. Oil level glass
17. Oil drain plug
(not shown)
18. Air tap
11
12
10
1
14
8
AC40G
9
AC30G_AC40G
9
12/8/05, 4:49 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Rubber feet
Unpacking
Fit the rubber feet on the
bracket on the front underside
of the tank using the screws,
washers and nuts supplied.
Due to modern mass production techniques, it is unlikely
that your GMC Power Tool is faulty or that a part is
missing. If you find anything wrong, do not operate the
tool until the parts have been replaced or the fault has
been rectified. Failure to do so could result in serious
personal injury.
2
Assembly
Oil
Handle
WARNING. The air compressor must be filled with oil
before first use.
To prevent possible spillage of oil during transport, the
compressor oil is supplied in a separate container. It must
be added to the compressor before turning the compressor
on. Failure to add the oil will cause non-repairable
damage to the compressor and will void the warranty.
The handle of the AC40G model must be fitted in the
following manner:
1. Remove the two grub screws from the plastic bag and
fit into the screw holes in the handle locating tubes.
1.Remove the plastic oil filling cap (14) located on the
top of the crank case of the compressor housing.
2
3
2. Insert the two ends of the handle into the fixing holes.
3. Tighten the screws to secure the handle in place.
1
2
Wheels
1.To fit the wheels (12) first insert an axle pin through
the wheel and then insert the spacer on the underside
of the wheel.
2.Use the oil supplied to fill the crank case until the oil
level as seen in the oil level glass (16) is up to the mid
point of the red circle.
2.Fit the wheel assembly
through the hole in the
bracket under the tank.
3.Replace the oil filling cap (14). Ensure the cap is fully
fitted and firmly in position.
3.Fit the flat washer, split
washer and nut. Tighten the
nut from the underside of
the wheel, and tap on the
wheel cover.
3
4.Repeat for the second wheel.
10
AC30G_AC40G
10
12/8/05, 4:49 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Open the valve by rotating
the air tap (18) so it is in
line with the air outlet
Air filter
OPEN
WARNING. The air filter must be added before first use.
Failure to fit the air filter will damage the compressor and
will void the warranty.
(refer to the OPEN picture).
To close the valve, rotate the
air tap so it is facing to the
right or the left side of the
air valve (refer to the CLOSED
picture).
4. Start the compressor by
following the procedure in
the section “To start and
stop the compressor”. For
the first time of operation,
run the compressor for 10
minutes with no load and
with the outlet valve open
to ensure all parts are well
lubricated.
1.Remove the plastic air
filter plug from the head of
the compressor.
2.To fit the air filter you
need to take it apart first.
Undo the wing nut, and
remove it along with the
washer from the air filter.
3.Remove the cover and the
air filter.
2
CLOSED
4.Push out the centre mounting piece and screw this into
the air inlet as firmly as possible with your fingers.
4
5
WARNING. Be aware that pressurised air will be
discharged from the outlet and care should be taken that
this discharge is not directed towards you the operator, or
other persons within the area.
To start & stop the compressor
1. Check the rating label on the compressor indicates
230V–240V.
2. Plug in the mains cable of the compressor to a
standard 240V household power point and turn on.
5.Replace the air filter holder, then the air filter, cover
and washer and wing nut.
3. To start the compressor, lift the On/Off switch (3) on
the pressure switch cover (2).
Pre-start routine
1. Ensure that the location for the compressor is clean,
dry and well ventilated.
2. Ensure the crank case has been filled with oil and is at
the correct level, and the air filter has been fitted.
3. Open the regulated output valve (6).
OFF
ON
11
AC30G_AC40G
11
12/8/05, 4:49 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
regulated outlet gauge will be incorrect. This gauge ONLY
indicates the correct pressure while air is being discharged
from the outlet.
4. To stop the compressor, push the On/Off switch down.
Operation
1.The pressure in the tank is controlled by the action
of the pressure switch located under the pressure
switch cover (2). When the set maximum pressure is
reached the pressure switch activates and the motor
is switched off. The pressure then decreases as the air
is used by the connected tool until the set minimum
pressure is reached after which the pressure switch
causes the motor to switch on again. The operator of
the compressor should be well aware that during use of
the compressor the motor will start and stop under the
influence of the rising or falling pressure in the tank.
The motor will start without any warning.
2.The maximum and minimum pressures are factory set
and the operator should not try to change them.
3.All accessories are
connected to the regulated
outlet valve (6).
5. On completion of the task, i.e. when you have finished
using the compressor, or when you are leaving the
compressor unattended, turn off the compressor in the
following way:
• Press down the on/off switch (3).
• Wait for the pressurised air to bleed from the release
valve under the pressure switch cover (2).
NOTE. When you press the button down you should hear
a short air discharge (Approx 1/2 second).
• Switch off the electrical
power supply and remove
the electrical plug.
• Pull the ring on the safety
valve (8) to ensure all the
pressurised air is released
from the tank, or open the
drain cock to release the
pressure from the tank.
4.The pressure of the
regulated outlet, as shown
on the regulated outlet
pressure gauge (7), can
be changed by turning the
regulating knob (5).
WARNINGS.
1. Never attempt to remove any part of the compressor
whilst the tank is under pressure.
2. Never attempt to remove any electrical component
whilst the compressor is connected to the power
supply. Switch off the power and remove the electrical
plug.
NOTE. To obtain the correct output reading on the
regulated output gauge, the air must be flowing through
the outlet.
The regulating valve should be adjusted and the gauge
read with the outlet valve open and the air being
discharged from the regulated outlet through the
accessory being used.
To increase the air pressure, rotate the regulating valve
clockwise. To decrease the pressure, rotate the regulating
valve anti-clockwise.
3. Do not adjust the safety valve.
4. Do not use an electrical extension cable.
5. If the release valve under the pressure switch cover
(2) fails to operate when the on/off button is pressed
down, switch the power supply off and determine the
nature of the fault.
6. Ensure that the lubricating oil is clean and that the oil
level is maintained at the mid point of the red circle in
the oil level glass (17).
NOTE. If you do not allow the air to discharge while you
are setting the regulator, the pressure as indicated on the
12
AC30G_AC40G
12
12/8/05, 4:49 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Take care when discharging air from the tank, i.e.
from the safety valve, the drain cock or the air outlet.
Compressed air can be extremely dangerous. Take care
the discharge air does not cause dust, stones or any
other foreign particles to be blown through the air and
that the air is discharged in a safe manner.
Troubleshooting
Trouble
Possible cause
Possible remedy
Power fault or supply voltage too low
Power cord too long or too thin
Check the power supply
Motor will not run, running too
slow or becoming excessively hot
Use authorised service centre
to replace the power cord
Faulty pressure switch
Faulty motor
Use authorised service centre
to repair or replace the switch
Use authorised service centre
to repair or replace the motor
Main compressor sticking/tight
Use authorised service centre
to repair or replace faulty parts
Moving parts damaged by heat
due to insufficient lubrication
Use authorised service centre to
check crankshaft, bearings, con rod,
piston rings, etc and replace
where necessary
Main compressor sticking/tight
Vibration or abnormal noise
Moving parts damaged or blocked
by foreign particle
Loose part
Use authorised service centre
to check and repair if necessary
Foreign body in main compressor
Piston connecting with the valve seat
Moving parts excessively worn
Use authorised service centre
to check and clean if necessary
Use authorised service centre
to increase size of gasket
Use authorised service centre
to repair or replace
13
AC30G_AC40G
13
12/8/05, 4:49 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting continued
Possible cause
Trouble
Suggested Remedy
Motor running too slow
Use authorised service centre to check
and repair if necessary
Insufficient pressure or decreased
outlet capacity
Dirty air filter cartridge
Leaking safety valve
Clean or replace the filter cartridge
Use authorised service centre to repair
or replace the switch
Leaking pipe
Use authorised service centre to check
and repair if necessary
Damaged gasket
Use authorised service centre to check
and repair if necessary
Damaged or carbon coated valve seat
Damaged piston ring or cylinder
Oil level too high
Use authorised service centre to check
and repair if necessary
Use authorised service centre to check
and repair if necessary
Maintain the oil at the correct level
Excessive oil consumption
Check and clean
Hole in oil filling cap (14) blocked
Use authorised service centre to check
and repair if necessary
Piston ring and/or cylinder worn or
damaged
3. After each day of
Maintenance
operation, use the drain
cock (11) under the
tank to drain off any
condensate.
1. After the first 10 hours of working, empty the crank
case of oil and refill with clean oil by removing the
crank case oil plug (left hand side of the crank case at
the bottom)
4. Regularly check the air
filter cartridge inside the
air filter assembly (17)
and replace the cartridge
when necessary.
NOTE. Use good quality compressor lubricating oil.
• SAE30 or L-DAB 100 over 10°C
• SAE10 or L-DAB 68 under 10°C
2. After each subsequent 500 hours of operation, again
drain the oil and refill the crank case with clean oil.
14
AC30G_AC40G
14
12/8/05, 4:49 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Check daily the operation of the safety valve. This
check should be performed when the tank contains
close to max pressure in the tank.
To check the valve, pressurise the tank, and pull the ring
OUTWARDS on the safety valve.
Air should discharge from the valve.
Release the ring of the safety valve. When the ring is
released the air discharge must stop.
Cleaning
1.Keep the tool’s air vents unclogged and clean at all
times.
2.Remove dust and dirt regularly. Cleaning is best done
with a soft brush or a rag.
3.Re-lubricate all moving parts at regular intervals.
4.If the body of the compressor needs cleaning, wipe it
with a soft damp cloth. A mild detergent can be used
but nothing like alcohol, petrol or other cleaning agent.
WARNINGS.
Safety glasses must be worn when performing this test.
5.Never use caustic agents to clean plastic parts.
Do not have your face close to the safety valve when
performing this test as air will discharge from the valve at
a high force.
If the safety valve does not operate correctly in any way
as described above, turn off the compressor immediately
and have the compressor and safety valve checked and
tested at an authorised Service centre.
Caution. Water must never come into contact with
the tool
Power cord maintenance
Only an authorised service centre should replace the
cordset or carry out other repairs. If the cordset is
damaged or worn, have it repaired or replaced by an
authorised service centre.
DO NOT CONTINUE TO USE THE COMPRESSOR IN ANY
WAY IF THE SAFETY VALVE DOES NOT WORK AS ABOVE.
General inspection
1. Regularly check that all the fixing screws are tight.
2. The supply cord of the tool should be checked
frequently for damage. If damaged, have the cordset
replaced by an authorised service facility to avoid
a hazard.
15
AC30G_AC40G
15
12/8/05, 4:49 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Carefully read the entire Instruction Manual
before using this product.
With continuing product development changes may
have occurred which render the product received
slightly different to that shown in this instruction
manual. The manufacturer reserves the right to
Before returning this product for a
Warranty Claim or any other reason
Please Call 1300 880 001 (Australia)
or 0800 445 721 (New Zealand)
change specifications without notice. Note:
Specifications may differ from country to country.
When you make your call, please have
the following information at hand:
• GMC Product Type • GMC Product Code
A GMC Service Engineer will take your call and, in
most cases, will be able to solve your problem over
the phone.
The GMC 777 Helpline operates from 7am to
7pm, 7 days a week (EST). This allows you
to contact GMC directly with any queries and
technical questions you have regarding
our products.
You are welcome to use this phone-in service to
make suggestions or give comments about any
GMC product.
45–55 South Centre Road
Melbourne Airport
Victoria, Australia 3045
Tel: (03) 8346 1100 Fax: (03) 8346 1200
Save this Manual for future reference.
AC30G_AC40G
16
12/8/05, 4:49 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
|