1080P
16x16 3GSDI Matrix
GEF-3GSDI-16416
User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
1
Introduction
Operation Notes
Features
2
3
4
Panel Layout
Front Panel
4
5
Front Panel Descriptions
6
Panel Layout
Back Panel
6
7
Back Panel Descriptions
8
Connecting And Operating The 16x16 3GSDI Matrix
Wiring Diagram
8
9
The Standby Screen
9
Displaying the Firmware Version
Displaying the Boot Loader Version
Switching between RS-232 and RS-485 Protocols
Displaying the Routing Status
Routing Sources
9
10
12
12
13 IR Remote Description
14 IR Remote Installation
15 IR Code Configuration
16 RS-232 Serial Control
16
17
18
21
22
Settings
Reference Signal Functions
IP Configuration Functions
General Functions
Commands
25 IP Control
25
26
27
28
View Matrix Status
Masking
IP Configuration
Backup / Restore
29 Firmware Update
31 Warning Messages
32 Rack Mount Safety Information
33 Specifications
34 Warranty
35 Licensing
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
Congratulations on your purchase of the 16x16 3GSDI Matrix. Your complete
satisfaction is very important to us.
Gefen
Gefen delivers innovative, progressive computer and electronics add-on solutions
that harness integration, extension, distribution and conversion technologies.
Gefen’s reliable, plug-and-play products supplement cross-platform computer
systems, professional audio/video environments and HDTV systems of all sizes
with hard-working solutions that are easy to implement and simple to operate.
The Gefen 16x16 3GSDI Matrix
Now you can easily combine sixteen cross-platform computers and sixteen digital
displays using the 16x16 3GSDI Matrix. The Matrix provides a simple, reliable
and highly effective method of routing multiple computer workstations. Each
3GSDI source is capable of displaying video on any one of 16 3GSDI displays.
The Matrix can be controlled by using either the buttons on the front panel, the
built-in RS-232 interface, or the included IR remote.
How It Works
The 16x16 3GSDI Matrix has sixteen (16) inputs and sixteen (16) outputs.
Connect up to sixteen (16) 3GSDI sources to the 3GSDI input ports. Connect up
to sixteen (16) 3GSDI outputs to the displays. Plug in the power cord and power
on the Matrix. The connected displays will show video according to the selection.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION NOTES
READ THESE NOTES BEFORE INSTALLING OR
OPERATING THE 16X16 3GSDI MATRIX
•
There is no internal scaling in the 16x16 3GSDI Matrix. All of the attached
monitors must be able to display the resolutions output by the source
devices. For maximum compatibility it is recommended that only one
compatible/common resolution be used by all of the source devices.
•
Routing features can be accessed using RS-232 or using IP control.
•
IMPORTANT: If the unit is installed in a closed or multi-rack assembly, do
not block the ventilation holes of the enclosure.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
FEATURES
Features
•
•
Increases productivity
Supports resolutions up to 1080p, 1920x1200, and 2K.
•
•
•
Front panel control buttons for local switching.
Status LCD (shows routing status)
Serial interface for remote control via a computer or control automation
devices supports RS-232 and RS-485 protocols.
•
•
•
•
•
•
•
•
•
•
•
IP Control
Discrete IR remote control
Output masking command
Seamless switching using external Genlock
Standby mode
Grounding pin
IR Sensor
IR Extender
Power On/Off switch
Redundant Internal AC power supply
Rack mountable
Package Includes
(1) GefenPRO 16x16 3GSDI Matrix
(1) IR Remote Control unit
(1) AC Power Cord
(1) Set of Rack Ears
(1) User Manual
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PANEL LAYOUT
Front Panel
4
Download from Www.Somanuals.com. All Manuals Search And Download.
PANEL DESCRIPTIONS
Front Panel
1
LCD Display
Displays the current routing status of the Matrix and is also used to manage
source routing.
2
3
Power Switch
Turn the power ON or OFF using this switch.
Control Buttons
These buttons are used to navigate the LCD menu system. See pages 9 - 12
for more information.
◄
- Left
►
Select
- Right
- Select
4
Cancel Button
This button is used to return the user to the main status screen once a routing
change has been initiated and the user decides to not continue with the change.
5
6
IR Window
Receives signals from the IR Remote Control unit.
Power Indicator
This LED indicator will glow red when the power is turned on.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
PANEL LAYOUT
Back Panel
6
Download from Www.Somanuals.com. All Manuals Search And Download.
PANEL DESCRIPTIONS
Back Panel
1
Reference In Connector
Connect an external reference to this connector. Bi-level (black burst) and tri-
level sync are supported.
2
3
3G-SDI Output Ports (1 - 16)
Connect 3G-SDI monitors to these ports.
Grounding Terminal
Provides a discharge path to ground in case a short circuit occurs between the
“hot” lead of the power supply and the enclosure of the Matrix. The grounding
wire should be attached from the grounding terminal to an approved ground
path.
4
RS-232 Serial Port
Connects to the RS-232 control device. The 16x16 3GSDI Matrix may be
switched remotely using this port. See page 16 for more information.
5
6
IP Control Interface
Connect the 16x16 3GSDI Matrix to a network in order to use IP control.
110/220 AC Power Receptacles
Connect one power cord to both power receptacles. The redundant (secondary)
power cable should be connected to an electrical outlet on a different circuit.
7
Fuse Drawer
Each power receptacle houses a fuse drawer. Within each fuse drawer are two
(2) 250 V fuses. One fuse is active and the other is a spare.
8
9
3G-SDI Input Ports (1 - 16)
Connect 3G-SDI source devices to these ports.
Reference Loop Connector
Reference Loop connector.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTING AND OPERATING THE 16X16 3GSDI MATRIX
How to Connect the 16x16 3GSDI Matrix
1. Connect up to 16 3G-SDI source devices to the 3G-SDI inputs on the rear
panel of the 16x16 3GSDI Matrix using SDI cables.
2. Connect up to 16 3G-SDI displays to the 3G-SDI outputs on the rear panel
of the 16x16 3GSDI Matrix.
3. Connect the included power cord to the power input receptacle on the rear
panel of the 16x16 3GSDI Matrix. Connect the opposite end of the cable into
a open wall power socket.
How to Operate the 16x16 3GSDI Matrix
The 16x16 3GSDI Matrix offers a number of control options. The following
options can be used to control basic routing functions of the 16x16 3GSDI Matrix:
1. Front Panel Control Buttons - Pages 9 - 12.
2. IR Remote Control - Pages 13 - 15.
3. RS-232 Serial Control - Pages 16 -23.
4. IP Control - Pages 24 - 27.
Wiring Diagram for the GefenPRO 16x16 3GSDI Matrix
SDI CABLE
16x
3G-SDI Sources
Matrix
16x
3G-SDI Displays
GEF-3GSDI-16416
Attention: This product should always be connected to a grounded
electrical socket.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTING AND OPERATING THE 16X16 3GSDI MATRIX
The Standby Screen
The front panel of the 16x16 3GSDI Matrix has a 16 character 2 line LCD display.
This display will shows the current routing status of the Matrix and will be used to
perform routing commands and other operations. After the unit is powered on,
the Standby Screen will be displayed:
Displaying the Firmware Version
Press the ◄ button to display the firmware version:
Displaying the Boot Loader Version
Press the ◄ button again to display the boot loader version:
Press the ◄ button once more to return to the Standby Screen.
NOTE: The Cancel button can be pressed at any time to return to the Standby
Screen.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTING AND OPERATING THE 16X16 3GSDI MATRIX
Switching between RS-232 and RS-485 Protocols
Press the ► button to display the serial interface selection screen:
Use the ◄ or ► buttons to switch between RS-232 and RS-485 serial protocols.
The current selection is indicated by the cursor. In the example above, RS-232 is
the currently selected protocol.
Once the protocol has been selected, press the Select button to save the
changes.
RS-232
If the RS-232 protocol is selected, the LCD will show the following:
Press the Cancel button to return to the Standby Screen.
RS-485
If the RS-485 protocol is selected, another screen will be displayed asking to
specify whether or not the cable is terminated:
Use the ◄ or ► buttons to switch between TERMINATION Off and
TERMINATION On, then press the Select button to save the changes.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTING AND OPERATING THE 16X16 3GSDI MATRIX
In the example below, TERMINATION Off has been selected. The LCD will now
show that the RS-485 protocol has been selected, along with the termination-
type:
Press the Cancel button to return to the Standby Screen.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTING AND OPERATING THE 16X16 3GSDI MATRIX
Displaying the Routing Status
From the main screen, press the Select button. When the arrow cursor is next
to OUTPUT, pressing the ◄ or ► buttons on the front panel will show the current
routing state of each input and output. The example below shows that Input 1 is
routed to Output 1.
Pressing the ► button again will display the routing state of output 2 and so on.
Note that the number displayed next to INPUT may be different than the example
above, depending upon the current routing state.
Routing Sources
Example:
Route the source device connected to In 2 to the display connected to Out 1.
1. From the Standby Screen, press the Select button on the front panel to
display the routing status screen.
2. Press the Select button again to move the cursor to INPUT.
3. Press the ► button to set the source to Input 2. The source device
connected to In 2 is now routed to the monitor connected to Out 1.
4. Press the Cancel button to return to the standby screen.
NOTE: The Cancel button can be used to return to the standby screen at
any time.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
IR REMOTE DESCRIPTION
RMT-16416IR
Remote Control Unit
1
2
1
2
Activity Indicator
This LED will be activated momentarily each time a button is pressed.
Display and Source Selection Buttons (1 - 16)
These buttons are used to select which source is routed to a monitor.
Routing sources using the Remote Control unit
Issuing a routing command is a two step process. The first step is to select the
monitor (1-16) to which the source will be routed. The second step is to select the
source (1-16).
Example:
Route the source device connected to In 6 to the monitor connected to Out 4.
1. Press button 4 (Out 4) on the IR remote control unit.
2. Press button 6 (In 6) on the IR remote control unit.
The source connected to In 6 will be routed to the monitor connected to Out 4.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
IR REMOTE INSTALLATION
Installing the RMT-16416IR Battery
1. Remove the battery cover on the back of the IR Remote Control unit.
2. Insert the included battery into the open battery slot. The positive (+) side of
the battery should be facing up.
3. Replace the battery cover.
The Remote Control unit ships with two batteries. One battery is required for
operation and the other battery is a spare.
Battery Slot
CAUTION: Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
IR REMOTE CONFIGURATION
How to Resolve IR Code Conflicts
In the event that IR commands from other remote controls interfere with the
supplied IR Remote Control unit, changing the IR channel on the IR Remote
Control unit will fix the problem. The IR Remote Control unit has a bank of DIP
switches used for setting the IR channel.
The DIP switch bank is located underneath the battery cover.
Remote Channel 0:
Default
Remote Channel 1:
1
2
1
2
Remote Channel 2:
Remote Channel 3:
1
2
1
2
Exposed DIP Switch
bank between the
battery chambers.
It is important that the IR channel on the Remote Control unit, matches the IR
channel set on the 16x16 3GSDI Matrix. For example, if both DIP switches on
the IR Remote Control unit are set to IR channel 0 (both DIP switches down),
then the 16x16 3GSDI Matrix must also be set to IR channel 0. See page 22 on
how to change the IR channel on the 16x16 3GSDI Matrix.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 SERIAL INTERFACE
What features are available via the RS-232 serial communications port?
The 16x16 3GSDI Matrix can accept commands through the RS-232 serial
communications port located on the rear panel. The current RS-232 control
features are:
•
Switching/routing of inputs to outputs without the RMT-16416IR remote
control.
How do I use these features?
These features were initially intended for utilization by custom installers in
automated setups. However, these features can be tested and used by using any
Windows-based PC with a terminal program.
What pins are used for communication with the 16x16 3GSDI Matrix?
Only pins 2 (Receive), 3 (Transmit), and 5 (Ground) are used for communication.
A null-modem adapter should not be used with this product.
5 4 3 2 1
1 2 3 4 5
9 8 7 6
6 7 8 9
Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface
What are the communication port settings?
Bits per second ............................................................................................ 19200
Data bits ............................................................................................................... 8
Parity ............................................................................................................. None
Stop bits ................................................................................................................1
Flow Control .................................................................................................. None
16
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 SERIAL CONTROL
RS-232 Features
RS-232 remote functions are used to control this product’s features. Features
include input / output routing and reference signal functions . These features are
available only through the use of the serial port.
Functions Syntax
The syntax for each function is always the same:
#Function name → Space ( _ ) as function name end flag → Parameter 1 →
Space → Parameter 2 → Parameter n → Carriage Return ( \r ) →
Sample:
#FunctionName_param1_param2_param3_param4...\r
Syntax is NOT case sensitive.
Reference Signal Functions
Function
Description
#CHECKREF
Display the Reference In signal
#PRREFTABLE Display the table data
#CHECKREF Function
The #CHECKREF function detects the Reference In signal and displays the data
according to the Reference table.
Syntax:
#CHECKREF
Parameters:
None
17
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 SERIAL CONTROL
#PRREFTABLE Function
The #PRREFTABLE function displays the Reference In data table (timings) which
are recognized by the 16x16 3GSDI Matrix.
Syntax:
#PRREFTABLE
Parameters:
None
IP Configuration Functions
Function
Description
#ISPADD
Sets the IP Address
#SNETMASK
#SGATEWAY
#SPORT
Sets the Net Mask
Sets the Gateway
Sets the Port
#PRWEBADD
#RSTIP
Displays the current IP configuration
Set IP configurations to default settings
#ISPADD Function
The #ISPADD function specifies a new IP address.
Syntax:
#ISPADD param1 param2 param3 param4
Parameters:
param1
param2
param3
param4
IP address
IP address
IP address
IP address
[0 - 255]
[0 - 255]
[0 - 255]
[0 - 255]
Notes:
A reboot is required after using this function.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 SERIAL CONTROL
#SNETMASK Function
The #SNETMASK function specifies a new net mask.
Syntax:
#SNETMASK param1 param2 param3 param4
Parameters:
param1
param2
param3
param4
Net mask
Net mask
Net mask
Net mask
[0 - 255]
[0 - 255]
[0 - 255]
[0 - 255]
Notes:
A reboot is required after using this function.
#SGATEWAY Function
Specifies the new IP gateway.
Syntax:
#SGATEWAY param1 param2 param3 param4
Parameters:
param1
param2
param3
param4
IP address
IP address
IP address
IP address
[0 - 255]
[0 - 255]
[0 - 255]
[0 - 255]
Notes:
A reboot is required after using this function.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 SERIAL CONTROL
#SPORT Function
Specifies a new port for a Web server.
Syntax:
#SPORT param1
Parameters:
param1
Port
[0 - 255]
Notes:
A reboot is required after using this function.
#PRWEBADD Function
Prints the current IP configuration on the screen.
Syntax:
#PRWEBADD
Parameters:
None
20
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 SERIAL CONTROL
General Functions
Function
Description
#ACTIVEBOLO Enables the boot loader
#FADEFAULT
#RMTIRADD
#RSTIP
Sets IP Configurations to default settings
Set the remote IR channel
Sets IP configuration to default
#ACTIVEBOLO Function
The #ACTIVEBOLO function enables the boot loader. See the boot loader
instructions on page 28.
Syntax:
#ACTIVEBOLO
Parameters:
None
Notes:
This command must be typed twice in order to activate the boot loader.
#FADEFAULT Function
The #FADEFAULT function sets all inputs and outputs to factory (default)
settings.
Syntax:
#FADEFAULT
Parameters:
None
Notes:
The #FADEFAULT function will set the default routing state: Input 1 - Output 1,
Input 2 - Output 2, Input 3 - Output 3, and so on.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 SERIAL CONTROL
#RMTIRADD Function
The #RMTIRADD function set the remote IR channel.
Syntax:
#RMTIRADD param1
Parameters:
param1
IR channel
[0 - 3]
#RSTIP Function
Sets IP configuration to default (192.168.0.70)
Syntax:
#RSTIP
Parameters:
None
Notes:
This command requires the unit to be rebooted in order to take effect.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 SERIAL CONTROL
Commands
Command
Description
M
R
S
Returns the current routing status of matrix
Routing command
Routes a single input to all outputs
M Command
The M command displays the current routing status of the matrix.
Syntax:
m
Parameters:
None
R Command
The R command allows specific routing of inputs and outputs.
Syntax:
r param1 param2
Parameters:
param1
param2
Ouput
Input
[1 - 16]
[1 - 16]
23
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 SERIAL COMMANDS
S Command
The S command routes a single input to all 16 3GSDI outputs.
Syntax:
s param1
Parameters:
param1
Input
[1 - 16]
Notes:
Setting param1 to a value of 0 will place the matrix in one-to-one mode. This
means that Input 1 will be routed to Output 1, Input 2 will be routed to Output 2,
and so on.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
IP CONTROL
The GefenPRO 16x16 3GSDI Matrix supports IP-based control using an
integrated Web interface. To access this feature, an IP address, subnet, gateway,
and port number need to be set on the 16x16 3GSDI Matrix (Default IP:
192.168.0.70 Subnet: 255.255.255.0 Gateway: 192.168.0.1 Port: 80). Consult
the network administrator to obtain the proper IP address and settings for this
product to properly communicate on the network.
The IP control setting can be configured via the RS-232 control interface. Once
this has been accomplished, access to the Web Interface is possible. Simply type
the IP address that was assigned to the product in a web browser to access the
View Matrix Status page.
View Matrix Status
The Main Page will display the current status and can also be used to create
routes.
To create a new route, follow the steps below:
1. Select which outputs will display the source by clicking on each check box.
2. Select the radio button of the input that will be routed to each output.
3. Click the SWITCH button to update the new routing configuration.
This page will automatically refresh every minute. However, at anytime the
“Refresh” button can be pressed to refresh the status of the Matrix.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
IP CONTROL
Masking
The Masking page is used to hide an output from displaying any video. From
this page, all outputs can be set to “Active” or “Mask”. When an output is set to
“Active”, it will function normally. When an output is set to “Mask”, it will not output
any video. To set the “Active” or “Mask” mode, follow the steps below.
1. Select either “Active” or “Mask” for any number of desired outputs.
2. Press the “Submit” button to initiate the change(s).
After this command is complete the user will be returned to the Main Page.
This page will automatically refresh every minute, however, at anytime the
“Refresh” button can be pressed to refresh the status of the matrix.
NOTE: All masked outputs will become active if the unit is power-cycled.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
IP CONTROL
IP Configuration
The IP Configuration page is used to set the IP settings that will be used to
access the Web interface. The following items can be configured from this menu.
•
•
•
•
•
IP Address (Default: 192.168.0.70)
Subnet (Default: 255.255.255.0)
Gateway (192.168.0.1)
Port (Default: 80)
To change these settings follow the steps below.
1. Enter the desired network information into the fields provided.
2. Press the “Save” button to initiate the change(s).
Note: After this command is complete the user will be returned to the View
Matrix Status page. Settings made on this page will not take effect until the
unit is restarted. Disconnect the power from the unit and reconnect power for
changes to take effect.
At anytime, the “Reset” button can be pressed to return the IP settings to their
defaults.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
IP CONTROL
Backup / Restore
The Backup/Restore page is used to backup and restore complete setup
configurations.
Note: This feature will be implemented in a future release.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
FIRMWARE UPDATE
Firmware Update Procedure
To Begin the update procedure the unit’s Boot Loader must be activated. To
activate the Boot Loader please follow the procedure below:
If the unit is already powered on, the following RS-232 command can be
used to activate the Boot Loader:
1. Connect RS-232 cable to PC and activate a terminal program.
2. Type the command: #ACTIVEBOLO followed by the ENTER key.
3. Re-type the command: #ACTIVEBOLO and press the ENTER key.
If the unit is not powered on, follow the instructions below to activate the
Boot Loader:
1. Connect RS-232 cable to PC and activate a terminal program.
2. Make sure the terminal program is set to the following:
a. Baud rate = 19200
b. Stop bits = 1
c. Data bits = 8
d. Flow control = None
3. Press the following three buttons on the front panel of the 16x16
simultaneously, while powering-on the unit:
a. select
b. < (left cursor)
c. > (right cursor)
Once the Boot Loader is activated the following message should appear:
16x16 Boot Loading
================== Main Menu ============================
Download new program -------- 1
Cancel ---------------------- 2
=========================================================
29
Download from Www.Somanuals.com. All Manuals Search And Download.
FIRMWARE UPDATE
Follow the on-screen instructions to complete the firmware update
process:
1. Press [1] on the computer keyboard to begin downloading program to the
temporary memory.
2. A message will appear in Hyperterminal:
Waiting for the file to be sent ... (press ‘a’ to abort)
3. In Hyperterminal, click Transfer > Send File...
4. Click Browse... and select the .BIN file you wish to upload.
5. Select Ymodem for the protocol.
6. Press Send on the Send File dialog box.
7. Wait until the download process is finished. The next text will appear on the
screen:
Download Completed Successfully!
----------------------------------------------
Name:
Size:
3GSDI16x16_e_1_6.bin
200416 Bytes
------------------------------------
Memory copy, please wait...............Finished to copy
Execute the new version
GEFEN
16x16 3GSDI MATRIX
8. The updated process is now complete.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING MESSAGES
System Failure
In the case of a critical malfunction, the following warning message will be
displayed on the Main Display:
If the 16x16 3GSDI Matrix is connected to a PC using a terminal program, the
following message will appear on the display:
System failure !!!
Power-down the Matrix immediately and contact Gefen Technical Support. See
Asking for Assistance at the beginning of this manual.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
RACK MOUNT SAFETY INFORMATION
a. Maximum recommended ambient temperature: 45 ˚C
b. Increase the air flow to maintain the temperature inside the rack.
c. Install the product evenly to avoid mechanical overload.
d. Connect an earthing wire between the an earthing stud and the
grounding pin on the chassis.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
Input / Output
•
•
•
SDI (SMPTE 259MI up to 360 Mbps)
HD-SDI (SMPTE 292M up to 1.485 Gbps)
3G-SDI (SMPTE 424M/425M up to 3.0 Gbps)
Supported Formats......................................................All SD, HD, and 3G formats
Maximum Resolution...........................................................1080p, 1920x1200, 2K
Input / Output Connector-type..........................................................................BNC
Input / Output Impedance.................................................................................75 Ω
Reference (Sync)............................................................NTSC, PAL, and Tri-Level
RS-232 Interface.................................................................................DB-9, female
Power Supply..................................................100 ~ 240 V AC (x2 for redundancy)
Power Consumption........................................................................................30 W
Operating Temperature...............................................0 ˚C ~ 45 ˚C / 32 ˚F ~ 104 ˚F
Storage Temperature...............................................-20 ˚C ~ 60 ˚C / -4 ˚F ~ 140 ˚F
Relative Humidity...............................................20% ~ 90% RH (no condensation)
Rack mountable................................................ 2U rack space, rack ears included
Dimensions............................................................................. 19” W x 2U H x 7” D
Shipping Weight........................................................................................... 29 lbs.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY
Gefen warrants the equipment it manufactures to be free from defects in material
and workmanship.
If equipment fails because of such defects and Gefen is notified within two (2)
years from the date of shipment, Gefen will, at its option, repair or replace the
equipment, provided that the equipment has not been subjected to mechanical,
electrical, or other abuse or modifications. Equipment that fails under conditions
other than those covered will be repaired at the current price of parts and labor in
effect at the time of repair. Such repairs are warranted for ninety (90) days from
the day of reshipment to the Buyer.
This warranty is in lieu of all other warranties expressed or implied, including
without limitation, any implied warranty or merchantability or fitness for any
particular purpose, all of which are expressly disclaimed.
1. Proof of sale may be required in order to claim warranty.
2. Customers outside the US are responsible for shipping charges to and from
Gefen.
3. Copper cables are limited to a 30 day warranty and cables must be in their
original condition.
The information in this manual has been carefully checked and is believed to
be accurate. However, Gefen assumes no responsibility for any inaccuracies
that may be contained in this manual. In no event will Gefen be liable for
direct, indirect, special, incidental, or consequential damages resulting from
any defect or omission in this manual, even if advised of the possibility of such
damages. The technical information contained herein regarding the features and
specifications is subject to change without notice.
For the latest warranty coverage information, refer to the Warranty and Return
PRODUCT REGISTRATION
Please register your product online by visiting the Register Product page
under the Support section of the Gefen Web site.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
LICENSING
lwIP is licenced under the BSD licence:
Copyright (c) 2001-2004 Swedish Institute of Computer Science.
All rights reserved.
Redistribution and use in source and binary forms, with or without modification,
are permitted provided that the following conditions are met:
1. Redistributions of source code must retain the above copyright notice, this
list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice,
this list of conditions and the following disclaimer in the documentation and/
or other materials provided with the distribution.
3. The name of the author may not be used to endorse or promote products
derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS’’ AND ANY
EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE,
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Rev A3
20600 Nordhoff St., Chatsworth CA 91311
1-800-545-6900 818-772-9100 fax: 818-772-9120
Pb
Download from Www.Somanuals.com. All Manuals Search And Download.
|