GARDENA
6500 SP Art. 1792
8000 SP Art. 1794
13000 SP Art. 1796
D
Betriebsanleitung
Schmutzwasserpumpe
GB Operating Instructions
Dirty Water Pump
F
Mode d’emploi
Pompe d’évacuation pour eaux chargées
NL Instructies voor gebruik
Vuilwaterpomp
S
I
Bruksanvisning
Spillvattenpump
Istruzioni per l’uso
Pompa sommersa per acqua sporca
E
P
Manual de instrucciones
Bomba para aguas sucias
Instruções de utilização
Bomba para águas sujas
DK Brugsanvisning
Dykpumpe til urent vand
Download from Www.Somanuals.com. All Manuals Search And Download.
2. For Your Safety
According to DIN VDE (German Electrical Engineers’ Associa-
tion) 0100, dirty water pumps may only be used in swimming
pools, garden ponds, and fountains if the pump is operated via a
residual-current device with a residual-current rating of ≤ 30 mA.
The pump must not be operated when there are persons in the
swimming pool or garden pond.
Residual-current device
For safety reasons we recommend that you always operate
the pump via a residual-current device (DIN VDE 0100-702 and
0100-738).
v Please contact your electrician.
In Austria, according to ÖVE B/EN 60 555 part 1 to 3, pumps
which are used in swimming pools and garden ponds, and
equipped with firm power cable should be fed via an ÖVE
approved isolating transformer – rated voltage must not exceed
230 V.
In Austria
In Switzerland mobile appliances which are used outdoors,
must be connected via a residual-current device.
In Switzerland
Mains power
According to DIN VDE (German Electrical Engineers’ Associa-
tion) 0620, mains power cables must not have a smaller cross-
section than the rubber-sheathed cables of the designation
H05 RNF (model 6500 SP and 8000 SP) or H07 RNF (model
13000 SP). The cable length must be at least 10 m.
Data indicated on the type plate must match technical data of
the mains supply.
v Take care that the electrical connections are made within
dry area, protected from flooding.
Protect plug and power cable from heat, oil and sharp edges.
v Don’t use the power cable for plugging off.
The power cable or the float switch must not be used for mount-
ing or relocating the pump. For submerging or lifting/securing
the pump, fix a rope to the pump’s carrying handle.
v Before operating the pump, first make a visual check, if there
is any damage of the pump (esp. regarding power cable and
plug).
Visual check
v Observe the minimum water level and the max. delivery
height (see 8. Technical Data).
A damaged pump must not be used.
v In case of damage, please have the pump checked by our
GARDENA Service Centre.
During manual operation, the pump must be switched off as
soon as all the liquid has been pumped away.
Manual operation
v Observe the pump at all times during manual operation.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes on use
v Clear the outlet line before use.
Dry-running operation causes increased wear and is to be
avoided. Therefore, in manual operation the pump must be
immediately unplugged when water fails to flow.
Avoid running of the pump for more than 10 min. against closed
delivery side of the pump.
Take care that the pump is located where the inlet openings at
the suction base are obstructed neither completely nor partly.
Stand the pump on a brick if using in a pond.
Thermal motor protector
The pump is automatically switched off on overheating by
the built-in thermal motor protector. After having cooled down,
the motor automatically switches on again (see 6. Trouble
Shooting).
Automatic deaerating
valve
The automatic deaerating valve eliminates any air pockets in
the pump. During this process, air escapes through the vent
bores
and air bubbles appear underwater. This is not a defect
4
of your pump, but serves to deaerate the pump.
It may take several seconds for the air to escape when the
pump is immersed for the first time.
4
3. Initial Operation
13 mm (1/2”)
15 mm (5/8”)
19 mm (3/4”)
Hose diameter
25 mm (1”)
38 mm (1 1/2”)
a
b
7
Hose connection
of universal fitting
7
Hose connection
Cut off topmost
Do not cut off
any nipples.
Cut off top two
nipple at
.
a
nipples at
.
b
The following connection kits are required for 13 mm to 19 mm
connections:
13 mm (1/2”): GARDENA Pump Connection Set, Art. No. 1750
15 mm (5/8”): GARDENA Tap Connector, Art. No. (2)902, and
Standard Hose Connector, Art. No. (2)916
19 mm (3/4”): GARDENA Pump Connection Set, Art. No. 1752
Best results in delivery capacity are achieved when using
38 mm (1 1/2”) hoses.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the hose:
The universal fitting
in the previous table.
allows you to connect all the hoses listed
7
1. Cut off nipples of the universal fitting , which are not needed,
7
to match the hose connection.
2. Screw the universal fitting
onto the pump.
7
3. Connect the hose to the universal fitting
.
7
We recommend that you secure 38 mm (1 1/2”) and 25 mm (1”)
hoses additionally with a GARDENA Hose Clip Art. No. 1591.
Only for 13 mm (1/2”) hose:
7
The universal fitting
can also be equipped with a GARDENA
7
Regulator Valve Art. No. 977 so that the contents of the out-
let line do not flow back through the pump after pumping. The
Regulator Valve can be ordered from your GARDENA dealer.
4. Operation
To ensure that the pump draws the water out, the water to be
drained must be at least 10 cm deep.
The float switch
turns the pump on automatically when the
Automatic operation:
5
water level exceeds the cut-in height and the water is pumped out.
The float switch turns the pump off again as soon as the water
level falls below the cut-out height.
5
1
2
1. Stand the pump on a firm surface
– or –
use a rope attached through the bore hole in the carrying
handle
to immerse the pump in a well or shaft.
2
During automatic operation, ensure that the float switch
can move freely.
5
2. Plug the power cable
into a mains socket.
1
Adjusting the Cut-in and Cut-out Height:
3
The maximum cut-in height and minimum cut-out height (see
8. Technical Data) can be adjusted.
v Push the cable of the float switch
into the float switch lock
.
3
5
5
Do not select a cable length that is too long or short to ensure
that the float switch can turn on and off properly.
• The higher the opening of the float switch lock , the higher
3
the cut-in and cut-out height.
• The shorter the length of cable between the float switch
5
and the float switch lock , the lower the cut-in height and the
3
higher the cut-out height.
The cable length between the float switch
and the float switch
5
lock
must always be at least 10 cm.
3
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Manual operation:
The pump remains in constant operation because the float switch
is bypassed.
1
2
1. Push the float switch
cable downward.
onto the float switch lock
with the
5
3
2. Stand the pump on a firm surface
– or –
use a rope attached through the bore hole in the carrying
handle to immerse the pump in a well or shaft.
2
5
3. Plug the power cable
into a mains socket.
1
The residual water height is only reached during manual opera-
tion since the float switch turns off the pump during automatic
operation before this water level is reached.
3
5. Cleaning
The pumps are virtually maintenance-free.
After having pumped chlorinated swimming pool water or other liq-
uids leaving residues, the pump should be rinsed with clear water.
Flushing the pump:
A Warning! Electric shock!
Risk of injury due to electric shock.
V Disconnect the pump from the mains before clean-
ing the suction base and feed impeller.
Cleaning the suction
base and feed impeller:
1. Unscrew the 6 Phillips screws
(model 6500 SP: 4 Phillips
8
screws) and pull the suction base
off the pump.
6
8
2. Clean the suction base
and the feed impeller
.
9
6
3. Reinstall the suction base
and screw in the Phillips screws
.
8
6
For safety reasons a damaged feed impeller
can only be
9
exchanged by the GARDENA Service Centre.
9
6
6. Trouble-Shooting
Problem
Probable cause
Remedy
v Open pressure line
Pump is running,
but doesn’t deliver.
Air cannot escape, since
pressure line is closed.
(e.g. kinked pressure pipe).
Air locks in the suction base.
v Wait for max. 3 minutes
until the pump deaerates
automatically over the vent
valve. If necessary, switch
off and start it again.
Feed impeller clogged.
v Disconnect plug and clean
feed impeller (see 5. Clean-
ing).
When starting the pump,
water height falls below the
min. water level.
v Submerge pump deeper.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Problem
Probable cause
Remedy
Pump doesn’t start or
suddenly stops during
operation.
Thermal overload switch has
switched the pump off due
to overheating.
v Disconnect plug and clean
feed impeller (see 5. Clean-
ing).
Observe max. media temper-
ature of 35°C.
No power.
v Check fuses and electric
connections.
Dirt particles are jammed
in the suction base.
v Disconnect plug and clean
suction base (see 5. Clean-
ing).
Pump runs, but output
suddenly decreases.
Suction base is clogged.
v Disconnect plug and clean
suction base (see 5. Clean-
ing).
Attention!
Repairs on electrical parts should only be done by our
GARDENA Service Centres.
If you have any problems with your Pump, please contact our Service.
7. Storage
Frost-free storage
Store the pump away from frost before the first frost sets in.
Disposal:
The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations.
(in accordance with
RL2002/96/EC)
8. Technical Data
Type
6500 SP
(Art. 1792)
8000 SP
(Art. 1794)
13000 SP
(Art. 1796)
Rated power
250 W
6,500 l/h
0.5 bar
5 m
380 W
8,000 l/h
0.5 bar
5 m
680 W
13,000 l/h
0.9 bar
9 m
Max. delivery capacity
Max. pressure
Max. delivery height
Max. submersion depth
Residual water height
9 m
9 m
9 m
30 mm
35 mm
35 mm
Contaminated water
with particle size of max.
Ø 25 mm
Ø 30 mm
Ø 30 mm
Power cable
10 m H05 RNF
10 m H05 RNF
10 m H07 RNF
Pump connection
38 mm (1 1/2”) / 25 mm (1”) graduated nipple,
option GARDENA Water hose Plug-in-system
Min. water level for operation
Weight approx.
80 mm
4.3 kg
35°C
100 mm
5.4 kg
35°C
100 mm
7.0 kg
35°C
Max. media temperature
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Type
6500 SP
(Art. 1792)
8000 SP
(Art. 1794)
13000 SP
(Art. 1796)
Mains voltage /
mains frequency
230 V / 50 Hz
200 mm
230 V / 50 Hz
205 mm
230 V / 50 Hz
235 mm
Min. cut-in height approx.
Min./max. cut-out height
approx.
65 mm / 165 mm
46 dB(A)
65 mm / 195 mm
47 dB(A)
65 mm / 225 mm
50 dB(A)
1)
Noise level LWA
1) Measuring method according to EN 60335-1
Cut-in / Cut-out height
The cut-in and cut-out height varies.
The residual water height is only reached during manual operation
(see 4. Operation).
Performance characteristics
m
bar
1.0
10
8
6
4
2
0
0.8
0.6
0.4
0.2
0
5000
10000
15000
l/h
9. Service
Warranty
GARDENA guarantees this product for 2 years (from date of
purchase). This guarantee covers all serious defects of the unit
that can be proved to be material or manufacturing faults. Under
warranty we will either replace the unit or repair it free of charge
if the following conditions apply:
• The unit must have been handled properly and in keeping
with the requirements of the operating instructions.
• Neither the purchaser or a non-authorised third party have
attempted to repair the unit.
The feed impeller is a wearing part and is not covered by the
guarantee.
This manufacturer’s guarantee does not affect the user’s existing
warranty claims against the dealer/seller.
If you have any problems with your pump, please contact our
Customer Service or return the defective unit together with
a short description of the problem directly to one of the
GARDENA Service Centres listed on the back of this leaflet.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
We expressly point out that, in accordance with the product
liability law, we are not liable for any damage caused by our
units if it is due to improper repair or if parts exchanged are not
original GARDENA parts or parts approved by us, and, if the
repairs were not carried out by a GARDENA Service Centre or
an authorised specialist. The same applies to spare parts and
accessories.
Product Liability
EU Certificate of Conformity
The undersigned
GARDENA Manufacturing GmbH Hans-Lorenser-Str. 40 · D-89079 Ulm
hereby certifies that, when leaving our factory, the units indicated below are in accordance with the
harmonised EU guidelines, EU standards of safety and product specific standards.
This certificate becomes void if the units are modified without our approval.
Description of the units:
Types:
Art. No.:
Dirty-Water Pump
6500 SP / 8000 SP / 13000 SP
1792 / 1794 / 1796
EU directives:
Machinery Directive 98/37/EC : 1998
2006/42/EC : 2006
Electromagnetic Compatibility 2004/108/EC
Low Voltage Directive 2006/95/EC
Directive 93/68/EC
Harmonised
European standards:
EN 292-1
Ulm, 29.05.2001
EN 292-2
EN 60335-1
EN 60335-2-41
Year of CE marking:
2001
Thomas Heinl
Technical Dept. Manager
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Deutschland / Germany
GARDENA
Manufacturing GmbH
Service Center
Hans-Lorenser-Straße 40
D-89079 Ulm
Produktfragen:
Croatia
Italy
Singapore
KLIS d.o.o.
GARDENA Italia S.p.A.
Via Donizetti 22
Hy - Ray PRIVATE LIMITED
40 Jalan Pemimpin
#02-08 Tat Ann Building
Singapore 577185
Stanciceva 79
10419 Vukovina
Phone: (+385) 1 6227770
20020 Lainate (Mi)
Phone: (+39) 02.93.94.79.1
gardena klis-trgovina.hr
info gardenaitalia.it
Phone: (+65) 6253 2277
@
@
hyray singnet.com.sg
@
Cyprus
FARMOKIPIKI LTD
P.O. Box 7098
74, Digeni Akrita Ave.
1641 Nicosia
Phone: (+357) 22754762
condam spidernet.com.cy
Japan
(+49) 731 490-123
Reparaturen:
KAKUICHI Co. Ltd.
Sumitomo Realty &
Development Kojimachi
BLDG., 8F
Slovak Republic
GARDENA Slovensko, s.r.o.
Panónska cesta 17
(+49) 731 490-290
service gardena.com
@
85104 Bratislava
5-1 Nibanncyo, Chiyoda-ku
Tokyo 102-0084
Phone: (+81) 33 264 4721
m_ishihara kaku-ichi.co.jp
Argentina
Phone: (+421) 263453722
Argensem® S.A.
@
info gardena.sk
@
Calle Colonia Japonesa s/n
(1625) Loma Verde
Czech Republic
Slovenia
@
GARDENA spol. s r.o.
Шнpskб 20a, и.p. 1153
627 00 Brno
GARDENA d.o.o.
Brodiљиe 15
Escobar, Buenos Aires
Phone: (+54) 3488494040
Luxembourg
Magasins Jules Neuberg
39, rue Jacques Stas
Luxembourg-Gasperich 2549
Case Postale No. 12
Luxembourg 2010
1236 Trzin
info argensem.com.ar
@
Phone: (+420) 800 100 425
gardena gardenabrno.cz
Phone: (+386) 1 580 93 32
@
Australia
servis gardena.si
@
Nylex Consumer Products
50-70 Stanley Drive
Somerton, Victoria, 3062
Phone: (+61) 1800 658 276
Denmark
South Africa
GARDENA
South Africa (Pty.) Ltd.
P.O. Box 11534
GARDENA Norden AB
Salgsafdeling Danmark
Box 9003
Phone: (+352) 401401
api neuberg.lu
@
spare.parts nylex.com.au
@
S-200 39 Malmö
Netherlands
GARDENA Nederland B.V.
Postbus 50176
Vorna Valley 1686
Phone: (+27) 11 315 02 23
info gardena.dk
@
Austria / Österreich
GARDENA
sales gardena.co.za
@
Finland
Habitec Oy
Martinkyläntie 52
01720 Vantaa
1305 AD ALMERE
Phone: (+31) 36 5210000
Österreich Ges.m.b.H.
Stettnerweg 11-15
2100 Korneuburg
Spain
GARDENA IBÉRICA S.L.U.
C/ Basauri, nº 6
La Florida
info gardena.nl
@
Tel.: (+43) 2262 7454536
Neth. Antilles
France
GARDENA
PARIS NORD 2
69, rue de la Belle Etoile
BP 57080
ROISSY EN FRANCE
95948 ROISSY CDG CEDEX New Zealand
Tél. (+33) 0826101455
service.consommateurs
gardena.fr
kundendienst gardena.at
@
Jonka Enterprises N.V.
Sta. Rosa Weg 196
28023 Madrid
Belgium
Phone: (+34) 91 7080500
P.O. Box 8200, Curaçao
GARDENA Belgium NV/SA
Sterrebeekstraat 163
1930 Zaventem
atencioncliente gardena.es
@
Phone: (+599) 9 7676655
Sweden
pgm jonka.com
@
GARDENA Norden AB
Försäljningskontor Sverige
Box 9003
Phone: (+32) 2 7209212
Mail: info gardena.be
@
NYLEX New Zealand Limited
Building 2, 118 Savill Drive
Mangere, Auckland
Phone: (+64) 0800 22 00 88
spare.parts nylex.com.au
@
Brazil
Palash Comércio e
Importação Ltda.
20039 Malmö
info gardena.se
@
Great Britain
Switzerland / Schweiz
GARDENA (Schweiz) AG
Bitziberg 1
@
Rua Américo Brasiliense,
2414 - Chácara Sto Antonio
São Paulo - SP - Brasil -
CEP 04715-005
GARDENA UK Ltd.
27-28 Brenkley Way
Blezard Business Park
Seaton Burn
Norway
GARDENA Norden AB
Salgskontor Norge
Karihaugveien 89
1086 Oslo
8184 Bachenbülach
Phone: (+41) 848 800 464
Phone: (+55) 11 5181-0909
Newcastle upon Tyne
info gardena.ch
@
eduardo palash.com.br
@
NE13 6DS
Turkey
info gardena.co.uk
info gardena.no
@
@
Bulgaria
DENEX LTD.
GARDENA / Dost Diþ Ticaret
Mümessillik A.Þ. Sanayi
Çad. Adil Sokak No.1
Kartal - Ýstanbul
Greece
Agrokip
Psomadopoulos S.A.
Ifaistou 33A
Poland
2 Luis Ahalier Str. - 7th floor
Sofia 1404
GARDENA Polska Sp. z o.o.
Szymanów 9 d
Phone: (+359) 2 9581821
05-532 Baniocha
Phone: (+90) 216 3893939
office denex-bg.com
@
Industrial Area Koropi
194 00 Athens Greece
V.A.T. EL093474846
Phone: (+48) 2272756 90
info gardena-dost.com.tr
@
gardena gardena.pl
@
Canada
Ukraine / Украина
ALTSEST JSC
4 Petropavlivska Street
Petropavlivska
GARDENA Canada Ltd.
100 Summerlea Road
Brampton, Ontario L6T 4X3
Phone: (+1) 9057929330
Portugal
Phone: (+30) 210 6620225
GARDENA Portugal Lda.
Recta da Granja do Marquês
Edif. GARDENA Algueirão
2725-596 Mem Martins
Phone: (+351) 21 922 85 30
service agrokip.gr
@
Hungary
GARDENA
Borschahivka Town
Kyivo Svyatoshyn Region
08130, Ukraine
info gardenacanada.com
@
Magyarország Kft.
Késmárk utca 22
1158 Budapest
Phone: (+36) 80204033
Chile
info gardena.pt
@
Antonio Martinic y Cia Ltda.
Cassillas 272
Phone: (+380) 44 4595703
upyr altsest.kiev.ua
Romania
@
Centro de Cassillas
Santiago de Chile
Phone: (+56) 2 2010708
MADEX INTERNATIONAL SRL
Soseaua Odaii 117-123,
Sector 1,
USA
Melnor Inc.
gardena gardena.hu
@
Iceland
3085 Shawnee Drive
Winchester, VA 22604
Phone: (+1) 540 722-9080
garfar_cl yahoo.com
@
Ó. Johnson & Kaaber
Tunguhalsi 1
Bucureєti, RO 013603
Phone: (+40) 21 352 76 03
madex ines.ro
Costa Rica
Compania Exim
Euroiberoamericana S.A.
Los Colegios, Moravia,
200 metros al Sur del Colegio Michael McLoughlin & Sons
110 Reykjavik
@
service_us melnor.com
@
ooj ojk.is
@
Russia / Россия
ООО ГАРДЕНА РУС
123007, г. Москва
1792-20.960.09/0507
Ireland
GARDENA
©
Manufacturing GmbH
D-89070 Ulm
Saint Francis - San José
Phone: (+506) 297 6883
Hardware Limited
Long Mile Road
Dublin 12
Хорошевское шоссе, д. 32А
Тел.: (+7) 495 647 25 10
http://www.gardena.com
exim_euro racsa.co.cr
info gardena-rus.ru
@
@
Download from Www.Somanuals.com. All Manuals Search And Download.
|