Gaggenau Ventilation Hood AW 200 790 User Manual

Operating and Assembly Instructions  
AW 200-790  
AW 201-790  
Extractor Hood  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
With your new extractor hood, working in the  
kitchen will be even more fun.  
The appliance offers you a number of  
advantages:  
– a good extraction capacity with low noise  
values,  
– a large number of control functions,  
– optimum illumination of the cooking surface by  
a dimmable halogen light.  
To ensure that you will be able to use this appli-  
ance in all its diversity, read through the operating  
and assembly instructions conscientiously before  
operating it for the first time. The instructions  
contain important notes on use, installation and  
maintenance of the appliance.  
On the following page you will find important  
notes on safety and operation. These will serve  
to ensure your personal safety and the lasting  
value of your appliance.  
You will find notes on page 4 that you ought to  
observe before operating the appliance for  
the first time.  
The chapters entitled “Structure and operating  
principle” and “Operation” will tell you all the  
things your extractor hood is capable of doing  
and how the appliance is operated.  
Tips and hints in the chapter entitled “Cleaning  
and care” will make sure that your appliance will  
stay operable and beautiful for a long time.  
And now we wish you lots of fun with your  
new extractor hood.  
Fig. 1  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety notes  
Read And Save These Instructions.  
WARNING - TO REDUCE THE RISK OF FIRE,  
ELECTRIC SHOCK, OR INJURY TO PERSONS,  
OBSERVE THE FOLLOWING:  
WARNING - TO REDUCE THE RISK OF INJURY  
TO PERSONS IN THE EVENT OF A RANGE  
TOP GREASE FIRE, OBSERVE THE  
FOLLOWING:  
a.) Use this unit only in the manner intended by the  
manufacturer. If you have questions, contact  
the manufacturer.  
a.) SMOTHER FLAMES with a close-fitting lid,  
cookie sheet, or metal tray, then turn off the  
burner. BE CAREFUL TO PREVENT BURNS. If the  
flames do not go out immediately, EVACUATE  
AND CALL THE FIRE DEPARTMENT.  
b.) Before servicing or cleaning unit, switch power  
off at service panel and lock the service  
disconnecting means to prevent power from  
being switched on accidentally. When the  
service disconnecting means cannot be locked,  
securely fasten a prominent warning device,  
such as a tag, to the service panel.  
b.) NEVER PICK UP A FLAMING PAN - You may be  
burned.  
c.) DO NOT USE WATER, including wet dishcloth or  
towels - a violent steam explosion will result.  
d.) Use an extinguisher ONLY if:  
CAUTION:  
1. You know you have Class ABC extinguisher,  
and you already know how to operate it.  
FOR GENERAL VENTILATION USE ONLY. DO NOT  
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE  
MATERIALS AND VAPORS.  
2. The fire is small and contained in the area  
where it started.  
3. The fire department is being called.  
WARNING - TO REDUCE THE RISK OF A  
RANGE TOP GREASE FIRE.  
4. You can fight the fire with your back to an exit.  
a.) Never leave surface units unattended at high  
settings. Boilovers cause smoking and greasy  
spillovers that may ignite. Heat oils slowly on low  
or medium settings.  
b.) Always turn hood ON when cooking at high heat  
or when cooking flaming foods.  
c.) Clean ventilating fans frequently. Grease should  
not be allowed to accumulate on fan or filter.  
d.) Use proper pan size. Always use cookware  
appropriate for the size of the surface element.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Important notes  
– Do not clean the appliance with a steam  
cleaning apparatus or with water pressure  
because this poses a risk of short-circuits.  
– Isolate the appliance from the mains during  
every maintenance operation. To do this, remove  
the mains plug or actuate the corresponding  
fuse.  
1.1 For your safety  
– Damaged appliances must not be operated.  
– The appliance must only be connected by an  
authorised specialist, paying attention to  
the relevant regulations of the power supply  
companies and the regional construction  
regulations.  
If the mains plug is not accessible, the appliance  
must be switched off at fuse point.  
Also observe the assembly instructions!  
– Connecting cables must not come into contact  
with hot cooking surfaces.  
– Repairs must be carried out by authorised  
specialists, thus ensuring electrical safety.  
– No warranty claims can be lodged in the event  
of damage caused by failure to observe these  
instructions.  
– Adequate incoming air must be ensured if a  
wood, coal, gas or oil heater or an open hearth is  
operated in the same room as the one in which  
the hood is installed.  
– Safe operation is possible whenever the partial  
vacuum in the place where the firing equipment  
is installed does not exceed 4 Pa (0.04 mbar).  
This can be achieved whenever the air needed  
for combustion is able to enter through openings  
that cannot be sealed, for example in doors,  
windows, incoming/exhaust air wall boxes or  
other technical means.  
– Do not operate the extractor hood without  
inserted lamps.  
– Never operate the appliance without a grease  
filter.  
– Hazardous or explosive substances and vapours  
must not be extracted!  
– The user is responsible for expert use and the  
perfect condition of the appliance.  
– Only ever operate the appliance under super-  
vision.  
Caution! Over-greased filters are a fire risk!  
Only ever deep-fry under the extractor under  
constant supervision. Be sure to clean the  
grease filter on a regular basis and change the  
activated charcoal filter.  
Fire risk! Do not flambé meals under the  
– If the appliance is to be operated only with the  
window open (to ensure adequate incoming air),  
you can use the window switch.  
extractor hood!  
– Operation of the extractor hood above a hearth  
for solid fuels, which poses a fire risk (e.g. sparks)  
is only permitted, if the hearth possesses a  
closed and fixed lid. The current local  
regulations must be obeyed. This does not apply  
to gas hobs and gas cookers.  
– Hobs may only be used under the extractor hood  
when pots and pans are placed on them!  
– When using more than 3 gas-operated rings at  
the same time, please operate the extractor  
hood at level 2 or higher. This prevents a build-  
up of heat in the appliance.  
A switch (normally open) is fitted on the window.  
On the appliance, this switch is connected to the  
window switch terminal on the main electronics.  
The appliance can now only be operated when  
the window is open.  
Important: the window switch must only be  
connected by an authorised specialist.  
Note: the light function works without restriction.  
– After a power failure, the extactor will not go on  
again automatically. You can recommence  
operation by turning a knob or by pressing any  
key.  
– For safety reasons, do not place any heavy  
objects on the top of the appliance.  
Technical modifications reserved.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.2 Operating for the first time  
1.3 About use  
Before operating the appliance for the first time,  
please pay attention to the following notes:  
– The appliance is intended solely for use in the  
household and must not be put to any other uses.  
– The appliance must be installed and connected  
by a specialist before it is operated for the first  
time.  
– In the event of malfunctions, first of all check the  
household fuses. If the problem has nothing to  
do with the power supply, please contact your  
specialist dealer or your local Gaggenau after-  
sales service.  
– Conscientiously read through the operating and  
assembly instructions before operating the  
appliance for the first time.  
– When children become old enough to operate  
the appliance, it is the legal responsibility of the  
parents or legal guardians to ensure that they  
are instructed in safe practices by qualified  
persons.  
– Remove the packaging from the appliance and  
dispose of it properly! Pay attention to the fact  
that there are accessories in the packaging!  
Keep packaging elements out of the reach of  
children!  
– Thoroughly clean the appliance before using it  
for the first time (see chapter “Cleaning and  
care”).  
– Before operating the appliance for the first time,  
check that the mains connection is in proper  
working order.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Features  
1 Ventilation duct  
2 Control panel  
3 Grease filters  
4 Lighting  
1
2
3
4
Fig. 2  
Installation accessories for exhaust air mode  
Stainless steel-design ventilation duct:  
LK 010-012 for ceiling heights of 7 4 - 8 6  
LK 010-022 for ceiling heights of 8 6 - 9 9  
Aluminium-design ventilation duct:  
LK 011-012 for ceiling heights of 7 4 - 8 6  
LK 011-022 for ceiling heights of 8 6 - 9 9  
Grease filter  
Installation accessories for circulating air mode  
saturation display  
Stainless steel-design ventilation duct:  
LK 010-112 for ceiling heights of 7 7 - 8 6  
LK 010-122 for ceiling heights of 8 6 - 9 9  
Lighting  
Delayed shut-off  
Extraction level intensive  
Extraction level 3  
Extraction level 2  
Extraction level 1  
Motor off  
Aluminium-design ventilation duct:  
LK 011-112 for ceiling heights of 7 7 - 8 6  
LK 011-122 for ceiling heights of 8 6 - 9 9  
Fig. 3  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Operation  
After they have been pressed, all functions  
selection keys except 0 (“Motor off”) are backlit in  
green.  
Light  
The lighting can be switched on or off, regardless  
of whether the wall extractor is in operation, by  
pressing the  
key (see Fig. 4).  
When you briefly press the  
key, the lighting is  
increased up to the maximum level.  
You can dim the lighting to the required level by  
keeping the  
key pressed.  
Fig. 4  
Fan levels  
Three fan speeds and one intensive speed are  
available (see Fig. 5). You set the fan level required  
for each respective cooking situation by pressing  
the function selector keys 1, 2, 3 or Int.  
or  
or  
or  
Fig. 5  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Int key for the intensive level should be  
pressed when browning and frying in an open pan  
(see Fig. 6).  
If you have switched on the hood by selecting the  
intensive level, it will be switched off again  
automatically after 5 minutes.  
Fig. 6  
If you press the Int key while the hood is running at  
fan level 1, 2 or 3, the electronic control will switch  
back automatically to the previously selected fan  
level after 5 minutes (see Fig. 7).  
Fig. 7  
If you would like to end the intensive level before  
the five minutes have elapsed, press the 0 key  
(“Motor off”) or select a different level (see Fig. 8).  
It is possible to switch off the extraction function at  
any time by pressing the 0 key (motor “off”).  
Fig. 8  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Special functions:  
Intensive time:  
You can set the intensive level running time to 3, 5  
or 10 minutes by simultaneously pressing the Int  
key and the 1, 2 or 3 key and you can store this  
setting (see Fig. 9). When delivered, the appliance  
is set to five minutes, i.e. the combination of the Int  
key and the key 2.  
or  
or  
Fig. 9  
Delayed shut-off:  
Delayed shut-off is possible at any level. First press  
the required key 1, 2, 3 or Int and then press the  
key (see Fig. 10).  
The delayed shut-off time for all levels is ten minu-  
tes. After these ten minutes, the ventilation switches  
off, but the lighting stays on.  
or  
or  
or  
Fig. 10  
Fig. 11  
Fig. 12  
Interval ventilation:  
Interval ventilation is a special feature of this  
appliance which periodically activates the fan for  
five minutes every hour. You can activate this  
function by simultaneously pressing the 0 key and,  
depending on the required extraction capacity, the  
1, 2 or 3 key (see Fig. 11).  
or  
or  
This mode of operation is indicated by alternating  
illumination of the  
key together with the  
corresponding fan level indicator.  
You can switch off interval ventilation by pressing  
the 0 key (see Fig. 12).  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Cleaning and care  
Cleaning the grease filters  
The grease filter saturation display F flashes after  
an operating time of 30 hours to you indicate to you  
that you should clean the grease filter (see Fig. 3).  
The grease filters can of course be cleaned at any  
time, even if the grease filter saturation display has  
not started to flash.  
The stainless steel grease filters can be removed  
easily for cleaning (see Fig. 13):  
Disconnect the power supply (switch off the fuse).  
Grip the grease filter handle and push the slide  
towards the rear. Then pull the grease filter  
downwards out of the holder; repeat the operation  
for the other grease filters.  
You can clean the stainless steel grease filters in a  
dishwasher at a maximum temperature of 130 °F /  
55 °C, where it should be supported vertically to  
allow food or rinsing residues to drain off.  
If possible, the inner parts of the housing should be  
wiped out in hot rinsing water when replacing the  
filters.  
Caution:  
Fig. 13  
when cleaning the inside of the housing, beware of  
protruding parts.  
After having cleaned them, re-insert the grease  
filters in the wall extractor in reverse order.  
Important:  
the handles of both grease filters must be  
visible after assembly.  
Press the F key to set the elapsed hours counter to  
zero. Flashing of the indicating lamp goes off.  
Fig. 14  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning the extractor hood  
Clean the exterior of your extractor hood with a soft  
cloth and mild detergent solution.  
Do not use any strong, caustic or abrasive cleaning  
agents. Do not use any abrasive sponges or  
brushes either.  
Clean the stainless-steel extractor hood (AW 200)  
with stainless steel cleaner.  
Do not place any objects with sharp-edged or rough  
bottoms (e.g. ceramic cups) on the hood.  
Circulating air mode  
The activated charcoal filter eliminates kitchen  
smells in the circulating air mode. In normal use  
(1 to 2 hours daily), the activated charcoal filter  
must be replaced approximately once a year.  
If no activated charcoal filter is installed, kitchen  
smells will not be eliminated.  
Replacing the activated charcoal filter:  
remove the stainless steel grease filters. Push in the  
clips on the side of the activated charcoal filter and  
remove the activated charcoal filter downwardly.  
Activated charcoal filters (KF 001-010) are available  
through your specialist dealer. Only use original  
filters.  
Activated charcoal filters do not contain any  
dangerous substances. They can be disposed of  
through the household refuse collection.  
Fig. 15  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Maintenance  
The appliance must be disconnected from the  
power supply during all repair work.  
If the appliance does not function correctly, check  
the fuses first.  
If the power supply is functioning correctly, but your  
appliance still does not work, please contact your  
Gaggenau dealer who will provide you with the  
address and telephone number of your nearest  
manufacturer’s authorized service agent or contact  
Gaggenau USA on (800) 828-9165. Specify the  
appliance type (see rating plate).  
Repairs may only be carried out by authorised  
technicians, in order to guarantee the safety of the  
appliance.  
Unauthorised tampering with the appliance will  
invalidate any warranty claims.  
Only ever use original spare parts.  
Lamp replacement  
Caution: disconnect the power supply before  
replacing lamps (switch off the fuse)!  
Fig. 16  
Caution: lamps may still be hot shortly after use!  
Risk of burns.  
– Detach the ring from the lamp cover. Note: make  
sure that the glass will not fall out (Fig. 16).  
– Pull out the lamp (Fig. 17).  
Defective lamps must only be replaced by lamps of  
the same type! (12 V/20 W/G4 lampholder)  
Inserting the lamp  
– Insert the lamp in the lampholder.  
Note: do not touch the halogen lamps with your  
hands. Use a cloth and touch the lamp only on its  
edges.  
– Engage the lamp cover.  
– Connect the appliance to the mains again.  
Fig. 17  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Assembly instructions  
WARNING - TO REDUCE THE RISK OF FIRE,  
ELECTRIC SHOCK, OR INJURY TO PERSONS,  
OBSERVE THE FOLLOWING:  
6.1 Technical data  
Max. weight depending on version: 28.5 kg  
Dimensions: 353/8 x 22  
a.) Installation work and electrical wiring must be  
done by qualified person(s) in accordance with  
all applicable codes and standards, including  
fire-rated construction.  
Electrical connection  
b.) Sufficient air is needed for proper combustion  
end exhausting of gases through the flue  
(chimney) of fuel burning equipment to prevent  
back drafting. Follow the heating equipment  
manufacturer’s guideline and safety standards  
such as those published by the National Fire  
Protection Association (NFPA), and the American  
Society for Heating, Refrigeration and Air  
Conditioning (ASHRAE), and the local code  
authorities.  
Pay attention to the rating plate data.  
The appliance must only be connected by an  
authorised specialist. The specialist is respon-  
sible for perfect functioning of the appliance at its  
installation location. He must explain the operating  
principle of the appliance to the user with refe-  
rence to the operating instructions. He must explain  
to the user how the appliance can be isolated from  
the mains whenever required.  
c.) When cutting or drilling into wall or ceiling, do  
not damage electrical wiring and other hidden  
utilities.  
Connection possibilities  
The plug of the connecting cable is inserted into  
the socket that is located behind the duct cover on  
the wall. If this is not possible, the disconnection of  
all the poles of the appliance from the mains must  
be achieved by way of the domestic fuse, or by  
using an accessible disconnecting device with a  
contact gap of at least 3.0 mm.  
d.) Ducted fans must always be vented to the  
outdoors.  
e.) If this unit is to be installed over a tub or shower,  
it must be marked as appropriate for the appli-  
cation and be connected to a GFCI (Ground  
Fault Circuit Interrupter) - protected branch  
circuit.  
f.) NEVER place a switch where it can be reached  
from a tub or shower.  
WARNING:  
To reduce the risk of fire, use only metal ductwork.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.2 Installation  
The applicable regulations of the energy supply  
companies and the regional construction  
regulations must be observed when installing  
the hood.  
This hood has been approved for installations as  
low as 30 and as high as 36 above the cooktop.  
101/4”  
167/8”  
The hood can be used in the exhaust or circulating  
air mode. The exhaust air can be routed into a  
separate exhaust air shaft or directly into the open  
through the outside wall.  
315/16”  
It is not allowed to pass the exhaust air into a flue  
or exhaust air chimney that is in operation or into a  
shaft that is linked to the heating basement. Consult  
the chimney sweep responsible for your district  
whenever you wish to pass the exhaust air into a  
chimney that is not in operation.  
22”  
min. 30”  
During the course of planning, a chimney sweep  
must be consulted if a room air-dependent hearth  
is operated in the same room as the one in which a  
hood is operated in the exhaust air mode. Adequate  
incoming air must be ensured. The applicable  
construction and safety regulations must be  
observed.  
Adequate incoming air must be ensured if a wood,  
coal, gas or oil heater or an open hearth is operated  
in the same room as the one in which the hood is  
installed.  
Fig. 18  
Safe operation is possible whenever the partial  
vacuum in the place where the firing equipment  
is installed does not exceed 4 Pa (0.04 mbar).  
This can be achieved whenever the air needed for  
combustion is able to enter through openings that  
cannot be sealed, for example in doors, windows,  
incoming/exhaust air wall boxes or other technical  
means.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flexible aluminium pipes, corrosion-protected  
sheet metal pipes and exhaust air pipes whose  
material conforms to fire B1 in accordance with  
DIN 4102 can be used. Exhaust air pipes should  
have a nominal diameter of 6 / 150 mm.  
The duct units listed below are available  
depending on the height of the ceiling:  
Installation accessories for exhaust air mode  
Pay particular attention to ensuring that  
Stainless steel-design ventilation duct:  
LK 010-012 for ceiling heights of 7 4 - 8 6  
LK 010-022 for ceiling heights of 8 6 - 9 9  
– the exhaust air ducts and pipes are kept as short  
as possible  
Aluminium-design ventilation duct:  
LK 011-012 for ceiling heights of 7 4 - 8 6  
LK 011-022 for ceiling heights of 8 6 - 9 9  
– the pipes are not laid at an acute angle, but as  
bends and that they are inserted into the shaft at  
an inclined upward angle and  
– there are no cross-sectional constrictions in the  
upward direction (this reduces the volume flow).  
Installation accessories for circulating air mode  
If long, rough exhaust-air pipes, many pipe  
bends or smaller pipe diameters are used, the  
air extraction rate will no longer be at an  
optimum level and there will be an increase in  
noise.  
Stainless steel-design ventilation duct:  
LK 010-112 for ceiling heights of 7 7 - 8 6  
LK 010-122 for ceiling heights of 8 6 - 9 9  
Aluminium-design ventilation duct:  
LK 011-112 for ceiling heights of 7 7 - 8 6  
LK 011-122 for ceiling heights of 8 6 - 9 9  
The manufacturer of the extractor hood  
accepts no liability for complaints which can  
be attributed to the design and layout of the  
pipework.  
The dimensions above refer to a distance of 5 3  
from the floor to the bottom edge of the hood.  
If required, custom made duct units are available at  
an extra charge.  
As standard, the blow-out opening of the extractor  
hood is in the upward direction.  
The socket must be placed behind the duct cover  
on the wall.  
To pass exhaust air through the outer wall, we  
recommend the use of our telescopic wall box  
TM 150-045 (Ø 6 / 150 mm).  
To use above gas cooker / gas hob  
Note:  
To prevent the ingress of water, e.g. condensate or  
rain water from an uncovered exhaust air shaft, our  
condensate separator RV 060-150 must be installed  
in the exhaust air line. The condensate separator  
must still be accessible after installation.  
Important: do not use all burners on the highest  
setting simultaneously over a longer period of time  
(max. 15 minutes). This will pose a risk of burns  
when touching the hot appliance exterior or parts of  
the extractor hood may become damaged.  
Switch the extractor hood to the highest setting  
when three or more burners of a gas cooker are  
used simultaneously.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important: before marking the securing holes,  
make sure that no electricity or water lines or  
other lines are laid at the drilling points in the wall.  
19/32"  
11 13/16"  
Proceed as follows:  
– From the bottom edge of the hood, mark a center  
line on the wall.  
12 3/16"  
9 1/16"  
– With the aid of the drilling template, mark the  
positions of the screws on the wall (Fig. 19).  
3"  
10 5/8  
"
16"  
Note: this hood has been approved for installations  
as low as 30 and as high as 36 above the cooktop.  
4"  
6 1/4"  
– Using the drilling template, drill the 6 holes for  
the hood (area I of the drilling template) and the  
two holes for suspending the chimney (area II of  
the drilling template). In the top two securing  
holes for the hood, fix the two hooks d with the  
countersunk screws c. Make sure that the hooks  
lie flatly on the wall. In certain circumstances you  
may have to countersink the drill holes. Fit the  
included dowels a in the other drill holes.  
min. 30”  
Fig. 19  
Note: at least one screw must be installed  
through a stud.  
Note: pay attention to any special accessories that  
you may have to fit.  
– Screw on the retaining bracket for the chimney  
paneling.  
– Detach the grease filters.  
– Hang the hood on the two hooks. Adjust the  
suspended element with the recessed head  
screw and align the hood using a spirit level  
(Fig. 20).  
Fig. 20  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
– Secure the hood on the wall with the four screws b  
(Fig. 21 and 22).  
For exhaust air mode proceed as follows:  
– Establish the pipe connection.  
– Establish the electrical connection.  
– Stainless steel chimney only (LK 010-012/022):  
pull the protective film off the chimney’s trims.  
Note: avoid damaging the sensitive metal surfaces.  
– Fit the top chimney duct unit into the base. Make  
sure that the fastening holes on the side are at the  
top.  
Fig. 21  
– Put both chimney duct units onto the hood.  
– Pull the top chimney duct unit up into its final  
position and secure it with 2 screws on the ceiling  
holder (Fig. 23).  
Note: avoid scratches when pulling the elements  
apart by placing the assembly template, for  
example, over the edge of the bottom chimney  
paneling to protect it.  
– Insert the grease filters.  
Fig. 22  
Fig. 23  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For circulating air mode use the installation set  
included with the ventilation ducts LK 010-112/122  
und LK 011-112/122. You also need an activated  
charcoal filter (KF 001-010).  
Proceed as follows:  
– Slightly loosen the screws of the retaining bracket  
for the chimney paneling. Hang the angle pieces  
onto the screws and tighten the screws.  
– Screw the circulating air switch module to the  
angle pieces (4 screws).  
– Shorten the flexible air pipe accordingly. Fix the  
flexible air pipe with hose clamps (Fig. 24).  
– Establish the electrical connection.  
– Stainless steel chimney only (LK 010-112/122):  
pull the protective film off the chimney’s trims.  
Note: avoid damaging the sensitive metal surfaces.  
– Fit the top chimney duct unit into the base. Make  
sure that the fastening holes on the side are at the  
top.  
– Put both chimney duct units onto the hood.  
– Pull the top chimney duct unit up into its final  
position and secure it with 2 screws on the ceiling  
holder (Fig. 25).  
Fig. 24  
Note: avoid scratches when pulling the elements  
apart by placing the assembly template, for  
example, over the edge of the bottom chimney  
paneling to protect it.  
– Insert the activated charcoal filters.  
– Insert the grease filters.  
Fig. 25  
18  
Download from Www.Somanuals.com. All Manuals Search And Download. 9000032538 en 06.05 EB  
GAGGENAU HAUSGERÄTE GMBH  
CARL-WERY-STR. 34 · 81739 MÜNCHEN  
GERMANY  
780 DEDHAM STREET  
CANTON, MA 02021  
USA  
Y (089) 45 90-03  
Y 800.828.9165  
FAX (089) 45 90-23 47  
EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Crate Amplifiers Stereo Amplifier CA125D User Manual
Crate Amplifiers Stereo Amplifier SM5 HP User Manual
Cub Cadet Snow Blower 850 SWE User Manual
Cub Cadet Trimmer CCBT User Manual
Curtis Flat Panel Television LCD1922 User Manual
Cypress Clock FS781 User Manual
Dyson Vacuum Cleaner DC14 User Manual
Everpure Water System 255349 User Manual
FieldServer Computer Drive FS 8700 16 User Manual
Flymo Trimmer 600 HD User Manual