www.GEAppliances.ca
Safety Instructions . . . . . . . . . 2, 3
Owner’s Manual and
Installation Instructions
Operating Instructions
Light Controls . . . . . . . . . . . . . . . .4
Vent Controls . . . . . . . . . . . . . . . .4
PVWS930
PVWS936
PVWT936
PVWG936
PVIG940
Care and Cleaning
Grease Filters . . . . . . . . . . . . . . . .5
Hood Lights . . . . . . . . . . . . . . . . .6
Hood Surfaces . . . . . . . . . . . . . . . .5
Stainless Steel Surfaces . . . . . . . . .5
Installation Instructions . . .7–16
Troubleshooting Tips . . . . . . . .18
Consumer Support
Consumer Support . . . Back Cover
Product Registration . . . . . .19, 20
Warranty . . . . . . . . . . . . . . . . . . . 21
Write the model and serial
numbers here:
Model # ________________
Serial # ________________
You can find them on a label
on the inside of the hood.
350A4502P595 03-07 ATS
LI3FQA Ed. 01/08
Download from Www.Somanuals.com. All Manuals Search And Download.
S
a
f
e
t
y
I
n
s
t
r
u
SAFETY PRECAUTIONS
c
t
D. Ducted fans must always be vented to the
WARNING –TO REDUCE THE RISK OF
i
o
outdoors.
A RANGE TOP GREASE FIRE:
n
s
A. Never leave surface units unattended at
high settings. Boilovers cause smoking and
greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
B. Always turn hood ON when cooking at
high heat or when cooking flaming foods.
( i.e. Crepes Suzette, Cherries Jubilee, Pepper
corn Beef Flambé).
WARNING –TO REDUCE THE RISK OF
FIRE, USE ONLY METAL DUCTWORK.
O
Do not attempt to repair or replace any
part of your hood unless it is specifically
recommended in this guide. All other
servicing should be referred to a qualified
technician.
p
e
r
a
t
i
n
g
I
n
C. Clean ventilating fans frequently. Grease
should not be allowed to accumulate on
fan or filter.
s
t
r
u
c
t
i
o
D. Use proper pan size. Always use cookware
appropriate for the size of the surface
element.
n
s
C
a
WARNING –TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
r
e
a
n
A. Installation work and electrical wiring
must be done by qualified person(s) in
accordance with all applicable codes and
standards, including fire-rated
d
C
l
e
a
n
construction.
i
n
B. Sufficient air is needed for proper
combustion and exhausting of gases
through the flue (chimney) of fuel
burning equipment to prevent back
drafting. Follow the heating equipment
manufacturer’s guideline and safety
standards such as those published by the
National Fire Protection Association
(NFPA), and the American Society for
Heating, Refrigeration and Air
g
T
r
o
u
b
l
e
s
h
o
o
t
i
n
Conditioning Engineers (ASHRAE), and
the local code authorities.
g
T
i
p
C. When cutting or drilling into wall or
ceiling, do not damage electrical wiring
and other hidden utilities.
s
C
o
n
READ ANDFOLLOW THIS SAFETY INFORMATION CAREFULLY.
s
u
READ AND SAVE THESE INSTRUCTIONS
m
e
r
S
u
p
p
o
r
t
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the hood controls.
Throughout this manual, features and appearance may vary from your model.
SafeyIructions
I
A
B
D
F
C
E
G
H
A - MOTORSTOP
H - LED TIMED INTENSIVE SPEED
B - SPEED DECREASE
D - LED:SPEED 1
F - LED: SPEED 2 AND METAL FILTER SATURATION
(WHEN FLASHING)
C - LED: SPEED 3 AND COAL FILTER SATURATION
(WHEN FLASHING)
E - MOTOR START AND SPEED INCREASE
G - TIMED INTENSIVE SPEED
I - “ON-OFF’ LIGHT
- MOTOR OPERATING PERFORMANCE CHECK-
UP. WHEN ANY OF THE BUTTONS ARE
PRESSED, ALL FOUR LEDS TURN ON TO
INDICATE THAT THE FOUR FAN SPEEDS
OPERATE PROPERLY. IF ONE OF THE LIGHTS
DOES NOT COME ON, IT MEANS THAT THE
SPEED CORRESPONDING TO THAT LIGHT
DOES NOT WORK.
OpeagIructions
Control Device Reset
The coal filter saturation is also indicated when the hood
is used in vented version.
Grease Filters:
After cleaning the grease filters, press buttons (A)-(E) for
2 seconds until you hear the beep and the LED stops
flashing.
The hood is provided with a storage device which counts
the number of hours of operation and which regulates
the lighting up of the coal filter saturation LEDS.
Coal Filter:
For the correct operation of this device, it is important
that the hood be switched off by pressing button (A)
before unplugging it for any maintenance work.
After replacing the cartridge, press both buttons (A)-(B)
for 2 seconds until you hear the beep. The LED will stop
flashing.
rdCleaing
Hood Operation
Use the low speed settings for normal use and the high
speed settings for strong odours or thick smoke.
Turn the fan on for approximately 5 minutes before you
start cooking in order to create some upwards drafts
through the hood.
The presence of drafts in the kitchen or in the hood
reduces the efficiency of the hood. These drafts
should be avoided wherever possible.
ips
This causes the heat, smoke, steam, grease and odours
produced during cooking to be pushed outwards, thereby
preventing them from drifting into other rooms.
Filters
The metal grease filters are manufactured using anodised aluminium and have an unlimited duration.
To remove the metal grease filter/s:
To replace the metal grease filter/s:
rubleshotingT
■ Unplug the hood from the mains
■ Follow the same procedure, but
T
socket.
backwards.
FOR MODELS PVIG940, PVWG936
■ Press the clips towards the centre and
remove the filters. Fig. 1.
Fig. 1
FOR MODELS PVWS930, PVWS936,
PVWT936
■ Press the handles and remove the
filters. Fig. 2.
Fig. 2
CnsmeSuport
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SafeyIructions
Care and cleaning of the vent hood.
www.GEAppliances.ca
Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of the vent hood.
Make sure lamps are cold before cleaning the hood.
To clean the filter/s
We recommend you wash the filters at least once a
month, by hand or in the dishwasher. Let the water drip
out of the holes on the edges and leave the filters to dry
completely before reinstalling them.
OpeagIructions
To clean the hood surface
For general cleaning operations, rub the external part of
the hood made of glass, using soapy water or household
cleaning products, rinsing it thoroughly and drying it
with a soft dry cloth to avoid marks being left by the
water.
Stainless Steel Surfaces
Do not use a steel-wool pad; it will scratch the surface.
Clean a small area (approximately 8” x 8” or
20.3 x 20.3 cm), rubbing with the grain of the
stainless steel if applicable.
Shake bottle well.
Place a small amount of CERAMA BRYTE® Stainless
Steel Cleaning Polish and Conditioner on a dry cloth
or dry paper towel.
Dry and buff with a clean, dry paper towel or soft
cloth.
rdCleaing
Repeat as necessary.
T
rubleshotingT
ips
CnsmeSuport
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Care and cleaning of the vent hood.
Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of the vent hood.
Replacement of lamps (Models PVWS930, PVWS936, PVWT936, PVWG936, PVIG940)
Unscrew the lamp diffusers.
Remove the blown lamp and replace
it with a new 20 Watt (max) 12 Volt
halogen lamp with a G-4 cap. Follow
the instructions given on the lamp
box. Do not touch the lamp with your
bare hands.
SafeyIructions
Fig. 3
Place the lamp diffuser back in place.
OpeagIructions
rdCleaing
ips
rubleshotingT
T
CnsmeSuport
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Instructions
Range Hood
Questions? Call 1-800-561-3344 or Visit our Website at: www. GEAppliances.ca
CAUTION:
BEFORE YOU BEGIN
Due to the weight and size of these vent hoods and to
Read these instructions completely and carefully.
reduce the risk of personal injury or damage to the
product, TWO PEOPLE ARE REQUIRED FOR
PROPER INSTALLATION
•
•
IMPORTANT –
Save these
instructions for local inspector’s use.
IMPORTANT –
Observe all
governing codes and ordinances.
• Note to Installer – Be sure to leave these
FOR YOUR SAFETY:
instructions with the Consumer.
WARNING –
Before beginning the
• Note to Consumer – Keep these instructions
installation, switch power off at service panel and lock
the service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to
the service panel.
for future reference.
• Skill level – Installation of this vent hood requires
basic mechanical and electrical skills.
• Completion time – 1 to 3 hours
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation is not
covered under the Warranty.
WARNING: - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
WARNING: - TO REDUCE THE RISK OF FIRE, OF FIER, USE
ONLY METAL DUCTWORK.
A. Installation work and electrical wiring must be
done by
qualified person(s) in accordance with all appli-
cable codes and standards, including fire-rated
construction.
Do not attempt to repair or replace any part of your
hood unless it is specifically recommended in this
guide. All other servicing should be referred to a
qualified technician.
CAUTION: - TO REDUCE THE RISK OF FIRE AND TO PROPERLY
EXHAUST AIR.
Be sure to duct air outside- Do not vent exhaust air
into spaces within walls or ceilings or into attics, crawl
spaces, or garages.
B. Sufficient air is needed for proper combustion
and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturers guid-
line and safety standards such as those published by
the National Fire Protection Association
(NFPA), and the American Society for Heating,
refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code
authorities.
C. When cutting or drilling into wall or ceiling do
not damage electrical wiring and other hidden
utilities.
D. Ducted fans must always be vented to the
outdoors.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
PRODUCT DIMENSIONS
13.4”
12”
13.4”
12”
PVWG936
PVIG940
15.7”
24.8”
15.7”
24.8”
5.9”
10.8”
PVWS930
PVWS936
5.9”
10.8”
PVWT936
38.6” min.
53.7” max.
15.75”
36”
19.3”
MODEL
W
30” - 36”
36”
D
H
T
PVWS930/936
PVWT936
PVWG936
PVIG940
19.3
19.3
33” - 45.3”
15.75”
38.6” - 53.7” 15.75”
36” - 42” - 48” 19.7”
39.4” 27.5”
33.4”
17.7”
17.7”
33.4” - 48”
1 Ft = 0.3 m
1” = 2.5 cm
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
Total
Equivalent
Length
DUCT FITTINGS
Use this chart to compute maximum
permissable lengths for duct runs to
outdoors.
Equivalent
Length*
1 ft.
(per foot
length
Quantity
Used
Duct Piece
Dimensions
Round,
straight
Note: Do not exceed maximum permissable
equivalent lengths!
1 ft.
(per foot
length
3¼” x 12”
straight
Maximum duct length:
100 foot for vent hoods.
90° elbow
45° elbow
8 ft.
6 ft.
Flexible ducting:
If flexible metal ducting is used, all
the equivalent feet values in the table
should be doubled. The flexible
metal duct should be straight and
smooth and extended as much as
possible.
3¼” x 12” or
90° elbow
15 ft.
9 ft.
Do NOT use flexible ducting.
3¼” x 12” or
45° elbow
Note: Any home ventilation system, such as a
ventilation hood, may interrupt the proper flow of
combustion air and exhaust required by fireplaces,
gas furnaces, gas water heaters and other
naturally vented systems. To minimize the chance
of interruption of such naturally vented systems,
follow the heating equipment manufacturer’s
guidelines and safety standards such as those
published by NFPA and ASHRAE.
3¼” x 12” or
90° flat elbow
20 ft.
1 ft.
7” round to
3¼” x 12”
transition
3¼” x 12” to 7” round
transition
Using a smaller diameter duct
size will reduce performance
5 ft.
7” round to
3¼” x 12”
transition 90° elbow
5 ft.
3¼” x 12” to7” round
transition 90° elbow
15 ft.
Round
wall cap
with damper
30 ft.
30 ft.
30 ft.
24 ft.
3¼” x 12”
wall cap with
damper
7” round
roof cap
Round
roof vent
*Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are
based on actual tests conducted by GE Evaluation
Engineering and reflect requirements for good
venting performance with any ventilation hood.
1 Ft = 0.3 m
1” = 2.5 cm
Total Duct Run
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
OPTIONAL ACCESSORIES
■
Kit 01235 Model PVIG940
Chimney + Structure 84 - 121.5 cm
(Venting)
■
■
■
Kit 01237 Model PVWG936
Chimney 51.5 cm
Kit 01238 Model PVWT936
Chimney 70 - 140 cm (Venting)
Kit 01239 Models PVWS930/ 936
Chimney 92.5 - 132 cm (Venting)
Duct tape
Pencil and
tape measure
Phillips and
Flat blade screwdrivers
Ductless Recirculating Kit
■
Kit 01378 Models PVWS930/ 936, PVWT936
Carbon Filter + Filtrating Deflector:
Changes Hood from Venting to
Filtrating
Electric drill with
1/8” and 3/8” bits
¼” pivoting hex socket
Safety glasses
■
Kit 01379 Model PVWIG940
Carbon Filter + Filtrating Deflector +
RUA: Changes Hood from Venting to
Filtrating
Spirit level
Flashlight
PARTS PROVIDED
MODELS PVWS930, PVWS936 AND PVWT936
• Hood canopy with internal blower, grease filters and
lights already installed
cUL Listed Wire nuts
• Duct covers
• Duct Cover support bracket
• Transition (may be already installed)
• Hardware Packet:
Pliers
Note: the hardware packet contains several fittings material.
For models PVWS930, PVWS936 and PVWT936, consider
what is listed below ONLY:
Hammer
Metal snips
•
• Hook with leveling screws x 2
• Template
• Use, Care and Installation Guide
• 10 x 60 drywall anchors x 2 (To attach duct cover
support bracket)
• 6 x 80 screws x 8 + washers x 8 (2 To attach duct cover
support bracket + 6 to attach the hood canopy)
• 3,5 x 9,5 screws x 6 (2 to attach the transition + 4 to
attach the duct cover)
Wire Cutter/Stripper
Saber saw or Key Hole Saw
Allen Wrench
Ladder
Additional Materials:
• 120V 60Hz. 15 or 20 Amp, 2 wire with ground.
Properly grounded branch circuit.
• Strain relief for junction box.
• 7” round metal duct or 3¼” x 12” rectangular duct, length
to suit installation.
1 Ft = 0.3 m
1” = 2.5 cm
1 0
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
Continued
PARTS PROVIDED -
DUCTING OPTIONS AND EXAMPLES
Closely follow the instructions set out in this manual.
All responsibility, for any eventual inconveniences,
damages or fires caused by not complying with the
instructions in this manual, is declined.
MODEL PVWG936
• Hood canopy with internal blower, grease filters and
lights already installed
• Glass vapour catcher
• Duct covers
Venting Methods
The hood is equipped with a transition B for discharge
of fumes to the outside (Ducting version).
• Duct Cover support bracket
• Transition (may be already installed)
• Hardware Packet:
Models PVWS930/ 936 and PVWT936: Minimum Duct
Size (Ducting/ Ductless version): 5" Round Pipe.
Note: the hardware packet contains several fittings material.
For model PVWG936, consider what is listed below ONLY:
Models PVWG936 and PVIG940: Minimum Duct Size
(Ducting/ Ductless version): 6" Round Pipe.
• Allen Wrench
• Lower support bracket x 2 (to attach the hood
canopy)
• Rubber tape (for glass vapour catcher)
• Bushes x 4 (for glass vapour catcher)
• 6 x 20 screws x 4 (for glass vapour catcher)
• Template
Model PVIG940
Models PVWS930/936, PVWT936
and PVWG936
Roof Pitch w/Flashing and Cap
Roof Pitch w/Flashing and Cap
• Use, Care and Installation Guide
• 10 x 60 drywall anchors x 2 (To attach duct cover
support bracket)
• 6 x 80 screws x 6 + washers x 6 (2 To attach duct cover
support bracket + 4 to attach the hood canopy)
• 3,5 x 9,5 screws x 14 (2 to attach the transition + 4 to
attach the duct cover + 8 to attach the lower support
brackets)
Pipe
Pipe
Pipe
Sidewall Cap
with Gravity
Damper
MODEL PVIG940
• Hood canopy with internal blower, grease filter and
lights already installed
Ducted Version
Ducted Version
• Glass vapour catcher
• Duct covers
• Chimney structure
Preparation
Do not cut a joist or stud unless absolutely necessary. If
a joist or stud must be cut, then a supporting frame
must be constructed.
• Transition (may be already installed)
• Use, Care and Installation Guide
• Hardware Packet:
Fittings material is provided to secure the hood to most
types of walls/ ceilings.
Note: the hardware packet contains several fittings material.
For model PVIG940, consider what is listed below ONLY:
However, a qualified technician must verify suitability of
the materials in accordance with the type of
wall/ ceiling.
• Allen Wrench
• Rubber tape (for glass vapour catcher)
• Bushes x 4 (for glass vapour catcher)
• 6 x 20 screws x 4 (for glass vapour catcher)
• Template
Before making cutouts, make sure there is proper
clearance within the ceiling or wall for exhaust vent.
Hood installation height above cooktop is the users
preference. The lower the hood is above the cooktop,
the more efficient the capturing of cooking odors,
grease and smoke.
• 6 x 80 screws x 4 + washers x 4(To attach the chimney
structure to the ceiling)
• 3,5 x 9,5 screws x 16 (8 to assemble the structure + 4 to
attach the duct covers + 2 to attach the transition + 2 to
attach the junction cover (may be already intsalled))
• 8 x 16 screws x 4 (to attach the canopy to the structure).
The hood shall be installed at 30" (76,2 cm) minimum
to 36" (91,4 cm) above the countertop.
Check your ceiling height and the hood height
maximum before you select your hood.
1 Ft = 0.3 m
1” = 2.5 cm
1 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
9. Models PVWS930/936 and PVWT936:
WALL INSTALLATION
FOR MODELS PVWS930, PVWS936, PVWT936 AND
PVWG936 ONLY
(For model PVIG940 installation, please refer to the
paragraph "CEILING INSTALLATION" on the next pages).
Attach the 2 hooks with leveling screws (provided in the
assembly kit) to the points marked on the template with
2 screws and then remove the template.
Model PVWG936:
Screw 2 screws on lower fixing point but do not tighten
them completely (leave a space of ½") they will serve to
hang the hood canopy.
1. Choose the assembly height which is most convenient
for the user and mark the wall behind the hob.
Models PVWS930/936 and
PVWT936
Model PVWG936
2. Mark the centre line of the hood and trace the vertical
line from the bottom of the hood to the ceiling.
3. Fasten the template using adhesive tape, making sure
the centre line corresponds with the bottom of the
hood.
4. Mark the centre of the fixing points (6 fixing points for
models PVWS930/ 936 and PVWT936; 4 fixing points
for model PVWG936) through the template on the wall
and then remove the template.
5. Trace a horizontal line on the wall 1” above the highest
fixing point and 1” below the lowest fixing point.
Ø 6 x 80
6. Find studs behind drywall by tapping wall or using a
stud finder. Mark the center of the studs with a vertical
line to the right and left of the marked fastener
location.
Ø 6 x 80
A. Centerline
B. Mounting Hooks (screws)
C. Fastener Locations
7. Note: All fastener location must span the studs
otherwise proceed as follows:
10. Install the bracket flush with the ceiling using the
drywall anchors provided with the appliance.
• Cutout drywall along marked lines.
• Install wood blocking between studs and make sure it
is flush with existing stud front. Make sure all
mounting screws will anchor to added studs.
• Replace drywall and refinish.
Models PVWS930/936 and
PVWT936
Model PVWG936
Ø 10 x 60
Ø 10 x 60
8. Mark the centre line again and the bottom of the hood
in same position as before and fasten the template to
the wall using adhesive tape as indicate above at point 3.
Ø 6 x 80
Ø 6 x 80
Models PVWS930/936 and PVWT936
11. Determine and make all necessary cuts in the wall for
the vent system. Install the vent system before the
canopy hood. See „Venting methods“ paragraph.
A. Centerline
B. Mounting Hook
Location
12. Determine the required height for the conduit and
cut a 1¼" hole at this location. Run wires through
hole according to the National Electrical Code or
CSA Standards and local codes and ordinances.
Note: If a In-line blower installation is required/
needed, then provide an additional hole/ conduit.
C. Fastener Locations
D. Mounting Height
Reference
E. Template
Model PVWG936
There must be enough power supply cable from the
fused disconnect (Or circuit breaker) box to make the
connection in the hood’s Junction box/ es.
Use caulking to seal all openings.
Do Not turn on power until installation is completed.
A. Centerline
B. Mounting Hook Location
C. Fastener Locations
D. Mounting Height Reference
E. Template
1 Ft = 0.3 m
1” = 2.5 cm
1 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
Continued
WALL INSTALLATION -
Ø 3.5 x 9.5
13. Model PVWG936:
Fix the 2 supplied brackets on the rear side of the
motor housing with 4 screws each.
Models PVWS930/936 and
PVWT936
Lower Support Bracket
Ø 3.5 x 9.5
Ø 3.5 x 9.5
Model PVWG936
14. Hang hood with the 2 mounting hooks (screws).
WARNING
Excessive Weight Hazard - Use two or more people to move
and install range hood. Failure to do so can result in back or
other injury.
15. Hang hood with the 2 mounting hooks (screws).Level
the appliance, using a carpenters level across bottom
of hood and (models PVWS930/ 936 and PVWT936
only) with leveling screws in mounting hooks.
18. Connect ducting to transition. Seal with duct tape.
Do not use duct smaller than the transition.
16. Secure hood with 2 screws on top and (models
PVWS930/ 936 and PVWT936 only) 2 screws on
bottom.
19. Electrical connection
Models PVWS930/936 and PVWT936
WARNING
• Electrical Shock Hazard
• Turn off power circuit at the service panel before wiring this
unit.
• 120 VAC, 15 or 20 Amp circuit required.
A. Centerline on Wall
B. Mounting Hooks
C. Mounting Screws
D. Leveling Screws
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/ YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC
SHOCK, THE GREEN AND YELLOW WIRE MUST BE
CONNECTED TO THE GROUNDING WIRE IN YOUR
HOME ELECTRICAL SYSTEM, AND IT MUST UNDER
NO CIRCUMSTANCES BE CUT OR REMOVED.
Ø 6 x 80
Model PVWG936
Failure to do so can result in death or electrical shock.
Remove the knockout and the Junction box cover and
install the conduit connector (cUL listed) in junction box.
1 Ft = 0.3 m
1” = 2.5 cm
Ø 6 x 80
17. Install the transition at the top of the hood in case it
has been removed.
1 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
Model PVWG936
Ø 3.5 x 9.5
Continued
WALL INSTALLATION -
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and
ordinances, in ½" conduit from service panel to
junction box.
Duct Cover
Models PVWS930/936 and PVWT936
Duct Cover
Ø 3.5 x 9.5
Connect black wire from service panel to black or red
in junction box, white to white and green to green-
yellow.
Close and secure junction box cover.
20. Check all light bulbs to make sure they are secure in
their sockets.
23. Model PVWG936:
Turn power (On) in service panel.
Check lights and blower operation.
Install the glass vapoure catcher with 4 screws and
bushes, place the rubber tape between the canopy
metal edge and the glass (see drawing at last pages
of this manual).
21. Install filters.
22. Install duct covers with 4 screws.
1 Ft = 0.3 m
1” = 2.5 cm
1 4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
Note the position of the front part of the hood and
proceed with the installation.
CEILING INSTALLATION
Note: All fastener location must span the studs
otherwise proceed as described in Step 4.
FOR MODEL PVIG940 ONLY
(For models PVWS930/ 936, PVWT936 and PVWG936
installation, please refer to paragraph "WALL
INSTALLATION" on previous pages).
4. Remove the template and keep it. Cut the dry wall of
the ceiling and remove it. Install some wooden strips of
suitable length 2” x 4” between the joists to create the
assembly points of the chimney flue. Use the template
for the dimensions and to define the space required.
Make sure you fasten the wooden strips safely and level.
Consult a professional if you are having difficulty or if
this is your first installation.
1. Choose the assembly height which is most convenient
for the user.
2. Measure the height “H” between the ceiling and the
floor
• establish the desired distance “D” between the floor
and the hood
• measure the height “X” of the hood
• you will obtain “L” by applying the following formula
L = H - (D + X).
5. Install the outlet duct. The female end should be 4½”
under the finished ceiling and fastened safely to the
joists. Do not use smaller ducts than those specified.
Once you have regulated the length of the telescopic
structure, fasten the two items using the 8 screws.
6. Install the conduit in the position marked in the hood
and measure out the length “L” from the ceiling (see
installation Step 2).
7. Install the dry wall around the duct and conduit then
proceed with the ceiling finish.
Ø 3.5 x 9.5
Template
8. Fasten the outlet duct to the female end situated 4”
underneath the ceiling.
9. Position the telescopic structure adjusted previously.
Fasten it to the ceiling using the 4 screws. The outlet
duct and the conduit pass along inside it.
3. Mark the centre lines of the hob or the distance on the
overlying ceiling. Use the centre lines marked on the
ceiling to position the assembly template.
10. Insert the chimney with the grid facing the ceiling and
fasten it on the sides to the telescopic structure using
2 screws.
1 Ft = 0.3 m
1” = 2.5 cm
1 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
Continued
CEILING INSTALLATION -
Ø 6 x 80
Ø 3.5 x 9.5
11. Insert the other chimney and keep it raised. Fix the
low connector to the connection box. Then fasten the
outlet duct onto the transition.
12. Bring the canopy together with the telescopic
structure, and fasten them together using 4 screws
(M8 x 16).
Then you can carry out the electrical connection
(consult Step 19 of “WALL INSTALLATION” instructions
on previous page).
13. Lower the chimney and fasten it on the sides to the
hood.
M8 x 16
14. Install the glass vapour catcher with 4 screws and
bushes, place the rubber tape between the canopy
metal edge and the glass (see drawing at last pages of
this manual)
1 6
Download from Www.Somanuals.com. All Manuals Search And Download.
SafeyIructions
Notes.
www.GEAppliances.ca
OpeagIructions
rdCleaing
T
rubleshotingT
ips
CnsmeSuport
17
Download from Www.Somanuals.com. All Manuals Search And Download.
s
n
Before you call for service…
o
i
t
c
u
r
t
Troubleshooting Tips
s
Save time and money! Review the charts on the following
pages ꢀrst and you may not need to call for service.
n
I
y
t
e
f
a
S
P r o b l e m
P o s s i b l e Causes
What To Do
Fan does not operate
when the switch is on
A fuse may be blown or a
circuit breaker tripped.
• Replace fuse or reset circuit breaker.
s
n
o
i
Fan fails to circulate air Excessively soiled ꢀlters.
or moves air slower than
normal
• Remove the ꢀlters, clean if necessary and replace
them. If cleaning and replacing the ꢀlters does not
correct the problem, call for service.
t
c
u
r
t
s
n
I
g
n
i
t
a
r
e
p
O
g
n
i
n
a
e
l
C
d
n
a
e
r
a
C
s
p
i
T
g
n
i
t
o
o
h
s
e
l
b
u
o
r
T
t
r
o
p
p
u
S
r
e
m
u
s
n
o
C
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Please place in envelope and mail to:
Veuillez mettre dans une enveloppe et envoyez à :
OWNERSHIP REGISTRATION
P.O. BOX 1780
MISSISSAUGA, ONTARIO
L4Y 4G1
(FOR CANADIAN CONSUMERS ONLY -
POUR RÉSIDENTS CANADIENS SEULEMENT)
19
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNERSHIP REGISTRATION CERTIFICATE – FICHE D’INSCRIPTION DU PROPRIÉTAIRE
Please register your product to enable us to contact you in Veuillez enregistrer votre produit afin de nous permettre de
the remote event a safety notice is issued for this product communiquer avec vous si jamais un avis de sécurité concernant
and to allow for efficient communication under the terms of ce produit était émis et de communiquer facilement avec vous en
our warranty, should the need arise.
REGISTER ON-LINE:
ENREGISTREMENT SUR INTERNET À :
vertu de votre garantie, si le besoin s’en fait sentir.
MAIL TO:
P.O. BOX 1780, MISSISSAUGA
POSTEZ À :
ONTARIO, L4Y 4G1
FIRST NAME / PRÉNOM
LAST NAME / NOM
MR. / M.
MRS. / MME
MS.
MISS/MLLE
For Canadian
Customers
STREET NO / NO RUE
STREET NAME / RUE
APT.NO/APP./RR#
POSTAL CODE/CODE POSTAL
CITY / VILLE
PROVINCE
AREA CODE/ IND. RÉG.
TELEPHONE/TÉLÉPHONE
E-MAIL/COURRIEL
IF YES/SI OUI : EXPIRATION
D/J
YES/OUI
DID YOU PURCHASE A SERVICE CONTRACT FOR THIS APPLIANCE?
AVEZ-VOUS ACHETÉ UN CONTRAT DE SERVICE POUR CET APPAREIL ?
NAME OF SELLING DEALER / NOM DU MARCHAND
Y/A
M
NO/NON
Pour les
MODEL / MODÈLE
consommateurs
canadiens
INSTALLATION DATE / DATE D’INSTALLATION
CORRESPONDENCE
ENGLISH
FRANÇAIS
Y/A
M
D/J
CORRESPONDANCE
SERIAL / SÉRIE
I do not wish to receive any promotional offers regarding this product.
Je ne désire pas recevoir d’offres promotionnelles concernant ce produit
.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
SafeyIructions
Range Hood Warranty.
All warranty service provided by our Factory Service Centers, or
Staple your receipt here.
Proof of the original purchase
date is needed to obtain service
under the warranty.
an authorized Customer Care® technician. To schedule service,
on-line, 24 hours a day, visit us at www.GEAppliances.ca, or call
1.800.561.3344.
For The Period Of: Mabe Will Replace:
One Year
From the date of the
original purchase
Any part of the range hood which fails due to a defect in materials or workmanship.
During this full one-year warranty, Mabe will also provide, free of charge, all labor and
in-home service to replace the defective part.
OpeagIructions
What Mabe Will Not Cover:
■Service trips to your home to teach you how to use
■Damage to the product caused by accident, fire, floods
the product.
or acts of God.
■Improper installation, delivery or maintenance.
■Incidental or consequential damage caused by possible
defects with this appliance.
■Failure of the product if it is abused, misused, or
used for other than the intended purpose or used
commercially.
■Damage caused after delivery.
rdCleaing
■Replacement of house fuses or resetting of circuit
breakers.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product repair as provided in this
Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a
particular purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home
use within Canada. If the product is located in an area where service by a Mabe Authorized Servicer is not available,
you may be responsible for a trip charge or you may be required to bring the product to an Authorized Mabe Service
Location for service.
T
rubleshotingT
Some provinces do not allow the exclusion or limitation of incidental or consequential damages. This warranty
gives you specific legal rights, and you may also have other rights which vary from province to province. To know
what your legal rights are, consult your local or provincial consumer affairs office.
ips
CnsmeSuport
Warrantor: Mabe Canada Inc. Burlington, Ontario
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Consumer Support.
GE Appliances Website
GEAppliances.ca
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day,
any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals,
order parts or even schedule service on-line.
Schedule Service
GEAppliances.ca
Expert Mabe repair service is only one step away from your door. Get on-line and schedule your service at
your convenience 24 hours any day of the year! Or call 1-800-461-3636 during normal business hours.
Extended Warranties
GEAppliances.ca
Purchase a GE extended warranty and learn about special discounts that are available while your warranty
is still in effect. You can purchase it on-line anytime, or call 1-888-261-2133 during normal business hours.
Mabe Consumer Home Services will still be there after your warranty expires.
Parts and Accessories
GEAppliances.ca
Individuals qualified to service their own appliances can have parts or accessories sent directly to their
homes (VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or
by phone at 1-800-661-1616 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally
should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause
unsafe operation.
Contact Us
GEAppliances.ca
If you are not satisfied with the service you receive from Mabe, contact us on our Website with all the details
including your phone number, or write to: General Manager, Customer Relations, Mabe Canada Inc.
Suite 310, 1 Factory Lane
Moncton, N.B. E1C 9M3
Register Your Appliance
GEAppliances.ca
Register your new appliance on-line—at your convenience! Timely product registration will allow for
enhanced communication and prompt service under the terms of your warranty, should the need arise.
You may also mail in the pre-printed registration card included in the packing material.
Download from Www.Somanuals.com. All Manuals Search And Download.
|