INTRODUCTION OVERVIEW
THERMOSTAT CONTROL
Display
Toggle Up/Down Buttons
Function Switch
Fan Auto/On Switch
PARTS DIAGRAM
Toggle Up/Down
Display
Switches
Reset
Switch
SW5
SW6
Function
Switch
Fan Auto/On
Switch
3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
ELECTRICAL SHOCK HAZARD—Turn off power at
the main service panel by removing the fuse or
switching the appropriate circuit breaker to the OFF
position before removing the existing thermostat.
PACKAGE CONTENTS/TOOLS REQUIRED
Package includes: Thermostat on base, thermostat cover,
wiring labels, screws and wall anchors.
Tools needed: Drill with 3/16″ bit, hammer, screwdriver.
TO REMOVE EXISTING THERMOSTAT
1. Turn off power to heating and cooling system by removing
the fuse or switching off the appropriate circuit breaker.
2. Remove cover of old thermostat. This should expose the wires.
3. Label the existing wires with the enclosed wire labels
before removing wires.
4. After labeling wires, remove wires from wire terminals.
5. Remove existing thermostat base from wall.
6. Refer to the following section for instructions on how
to install this thermostat.
TO INSTALL THERMOSTAT
IMPORTANT: Thermostat installation must conform to
local and national building and electrical codes and ordinances.
Note: Mount the thermostat about five feet above the floor.
Do not mount the thermostat on an outside wall, in direct
sunlight, behind a door or in an area affected by a vent or duct.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
TO INSTALL THERMOSTAT (cont.)
1. Turn off power to the heating and cooling system
by removing the fuse or switching off the appropriate
circuit breaker.
2. To remove cover, insert and twist a coin or screwdriver
in the slots on the sides of the thermostat.
3. Put thermostat base against the wall where you plan
to mount it. Make sure wires will feed through the wire
opening in the base of the thermostat.
4. Mark the placement of the mounting holes.
5. Set thermostat base and cover away from working area.
6. Using a 3/16″ drill bit, drill holes in the locations you
have marked for mounting.
7. Use a hammer to tap supplied anchors in mounting
holes.
8. Align thermostat base with mounting holes and feed
the control wires through the wire opening.
9. Use supplied screws to mount thermostat base to wall.
10. Insert stripped, labeled wires in matching wire
terminals. See “Wiring Diagrams” section of this
manual.
CAUTION!
Make sure exposed portion
of wires does not touch other wires.
11. Tighten screws on terminal block. Gently tug wire to
be sure of proper connection. Double check that each
wire is connected to the proper terminal.
12. Seal hole for wires behind thermostat with non-flammable
insulation or putty, or use a wall plate obtainable from
a local hardware or home building store.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
TO INSTALL THERMOSTAT (cont.)
13. Replace cover on thermostat by snapping it in place.
14. Turn on power to the system at the main service
panel.
15. Test thermostat operation as described in “Testing the
Thermostat”.
Wiring diagrams.
Table 1: Terminals for five wires heat/cool system
(RAK164D1 only)
Note: Connect G terminal of thermostat to Zoneline Gl
terminal for low fan speed or terminal Gh for high fan speed.
Only one can be selected.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 2: Terminals for six wires 2 heat/1 cool system
(RAK148D1 only)
Note: Connect G terminal of thermostat to Zoneline Gl
terminal for low fan speed or terminal Gh for high fan speed.
Only one can be selected.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuration mode.
The configuration mode is used to set the RAK148D1 and RAK164D1
to match your heating/cooling system. These thermostats function
with up to 2-stage heat pump systems (RAK148D1 only).
To configure the RAK148D1 and RAK164D1, perform the
following steps:
Note: Operation being set will blink in the display.
1. Slide the Function switch to the OFF position.
2. Remove the cover of the thermostat by gently pulling
on one of the corners.
3. Simultaneously hold the SW5 and SW6 buttons in
for 5 seconds while the thermostat is in OFF mode.
4. Press the
each screen.
or
button to change settings within
5. Press the SW6 button to advance to the next screen.
Note: The SW5 button will return you to the previous screen.
6. To exit configuration mode, slide the Function switch to Heat
or Cool.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
1. Temperature Scale (F or C)—
Choose Fahrenheit or Celsius.
Press the
to select.
or
button
Press the SW6 button to advance to the next screen.
2. Temperature Differential—
Stage 1—(1–9°F) (1–5°C)—
(Factory Setting is 2°F/1°C for
Each Stage)—Set the number of
degrees between your “setpoint” temperature and your
“turn on” temperature for first stage.
Press the
or
button to set differential value.
Press the SW6 button to advance to the next screen.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Temperature Differential—Stage
2—(RAK148D1 only) (1–9°F)
(1–5°C)—Set the number of
degrees between when stage 1
turns on and stage 2 turns on.
Press the
or
button to set differential value.
Press the SW6 button to advance to the next screen.
4. Minimum Cool Setpoint (60, 64,
66, 68, 70, 72, 74, 76°F) (15, 17, 19,
20, 21, 22, 23, 24°C)
Adjust to control the minimum Cool set temperature allowed.
Press the
or
button to select.
Press the SW6 button to advance to the next screen.
5. Maximum Heat Setpoint (65, 70,
72, 74, 76, 78, 80, 85°F) (18, 21, 22,
23, 24, 26, 27, 29°C)
Adjust to control the maximum Heat set temperature allowed.
Press the
or
button to select.
Press the SW6 button to advance to the next screen.
6. Room temperature offset (+9°F to
–9°F) (+5°C to –5°C)
Adjust to calibrate displayed room
temperature to match actual room temperature.
Press the
or
button to select.
Press the SW6 button to advance to the next screen.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Terminal designator descriptions.
R
C
— 24 VAC hot
— 24 VAC common
G
B
— Fan
— Heat active reversing
valve (RAK148D1 only)
W — Aux. heat
— Compressor
Y
Starting the thermostat.
CAUTION!
Do not use air conditioning when
the outdoor temperature is below 50 degrees. This can damage
your air conditioning system and cause personal injuries.
1. Move the Fan Auto/On switch
ROOM
to the Auto position.
2. Move the Function switch to
Cool or Heat, depending
on the season.
Testing the thermostat.
Once the thermostat is installed, it should be thoroughly tested.
CAUTION!
Do not use air conditioning when
the outdoor temperature is below 50 degrees. This can damage
your air conditioning system and cause personal injuries.
Cool Test
1. Slide Function switch to Cool mode.
2. Adjust set temperature so it is 5
degrees below room temperature.
3. Air conditioning should come on within a few seconds.
4. Adjust the set temperature so it is 2 degrees above the room
temperature and the A/C should turn off. Note: There is a 3
minute time delay and a 3 minute minimum run time for the
compressor when it turns on/off. (On some models, the fan
may also have a 3 minute minimum run time/off time delay).
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Heat Test
1. Slide Function switch to Heat mode.
2. Adjust set temperature so it is 5
degrees above room temperature.
3. Heat should come on within a few seconds.
4. Adjust the set temperature so it is 2 degrees below the room
temperature and the heat should turn off. Note: There is a 3
minute time delay and a 3 minute minimum run time for the
compressor when it turns on/off. (On some models, the fan
may also have a 3 minute minimum run time/off time delay).
Note: “Quick Heat Recovery” is activated each time the thermostat
is switched from Off or Cool modes to Heat mode. Electric heaters
are energized until the thermostat set point is reached. Heat pump
operation will resume at next call for heat (Heat pump only).
Fan Test
1. Slide Fan Auto/On switch to On position.
2. Indoor fan turns on.
3. Slide Fan Auto/On switch to Auto position.
4. Indoor fan turns off.
Operating functions.
Off
• In this mode, the thermostat will not turn on the heating or
cooling devices (manual fan can operate).
• Off is also used to access Setup mode.
Cool
Standby
• In this mode, the thermostat
controls the cooling system.
• Press the
or
buttons to set
Set
the desired temperature.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating functions.
Heat
Standby
Set
• In this mode, the thermostat
controls the heating system.
• Press the
or
buttons to set
the desired temperature.
Troubleshooting tips.
Problem
Solution
No display
Check for 24 VAC at thermostat;
display is blank when 24 VAC is
not present.
System fan does not
come on properly
Verify that wiring is correct.
Thermostat turns on and
off too frequently
Adjust temperature differential
(see Temperature Differential,
Stage 1).
Fan runs continuously
Check Fan Auto/On switch. If set to
ON position, fan will run continuously.
Room temperature is
not correct
Verify that wall hole is plugged
with putty or insulation; calibrate
thermostat (see Configuration mode).
Auxiliary heat not on
soon enough
Adjust differential for 2nd stage
(RAK148D1 only) heating, if required
(see Configuration mode).
Compressor doesn’t run
or turn off immediately
when changing function
or setting
There is a 3 minute time delay and
a 3 minute minimum run time for
the compressor when it turns on/off.
Fan doesn’t run or turn off
This is normal. On some models, the
immediately when changing fan may have a 3 minute minimum
function or setting
run time/off time delay.
Problem not listed above
Press the Reset button once;
display will be refreshed.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Thermostat Warranty.
Staple your receipt here.
Proof of the original purchase date is
needed to validate the warranty.
For The Period Of:
GE Will Replace:
One Year
From the date of the
original purchase
Full Replacement of the thermostat which fails
due to a defect in materials or workmanship.
What GE Will Not Cover:
■ Service trips to your location.
■ Improper installation. If you have an installation problem, contact your
installer. You are responsible for providing adequate electrical connections
to the product.
■ Failure of the product resulting from modifications to the product or due to
unreasonable use, including failure to provide reasonable and necessary
maintenance.
■ In commercial locations, labor necessary to move the unit, after it has been
initially installed, to a location where it is accessible for service by an individual
technician; or, if the instructions included in this manual have been disregarded.
■ Replacement of location fuses or the resetting of circuit breakers.
■ Damage to the product caused by improper power supply voltage, accident,
fire, floods or acts of God.
■ Incidental or consequential damage caused by possible defects with this
thermostat.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is
product exchange as provided in this Limited Warranty. Any implied warranties,
including the implied warranties of merchantability or fitness for a particular
purpose, are limited to one year or the shortest period allowed by law.
This warranty is extended to the original purchaser and any succeeding owner for
products purchased for use within the USA and Canada. In Alaska, the warranty
excludes the cost of shipping or service calls to your site.
Some states or provinces do not allow the exclusion or limitation of incidental or
consequential damages. This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state or province to province. To know
what your legal rights are, consult your local, state or provincial consumer affairs office
or your state’s Attorney General.
Warrantor: General Electric Company. Louisville, KY 40225
16
Download from Www.Somanuals.com. All Manuals Search And Download.
|