JKP35SP
GE® 27" Built-In Double Wall Oven
Dimensions and Installation Information (in inches)
Locate
junction box
for 24"models
56" MIN. above
cutout floor
KW Rating
2" x 4" or
equivalent
runners
C
L
6.8
5.1
240V
208V
Locate
10
junction box
for 27"models
either 5" MIN.
below cutout
floor or 44"
MIN. above
cutout floor
Allow 3/4"
A
for overlap
over all edges
of cutout
Breaker Size
30 Amps
30 Amps
240V
208V
C
B
Note: Cabinets installed adjacent to wall ovens
must have an adhesion spec of at least a 194°F
temperature rating. For 27” built-in single
ovens, if marks, blemishes or the cutout opening
is visible above the installed oven, it may be
necessary to add wood shims under the runners
and front trim until the marks or openings
are covered.
Suitable
bracing
Access
from
to support
runners
adjacent
18"
D
cabinet
required
Over centerline
of cabinet
G
(must support 300 lbs.)
Cabinet
27"
27" min.
23-5/8"
25" min. - 25-1/4" max
50-1/8" max
E
21
Conduit
(48-1/2" Long)
A – Cabinet width required
B – Minimum cabinet depth
C – Opening width
D – Opening height
E – Recommended minimum cutout location from floor
Oven
2" X 4" or
equiv. runners
(cutout floor)
F
Minimum
cutout location
from floor
21" MIN.
door opening
allowance
Note: Door handle protrudes 3" from door face.
Cabinets and drawers on adjacent 45° and 90°
walls should be placed to avoid interference with
the handle.
13-1/4"
F – Overall depth*
23-5/8"
51-7/8" - 52-3/4"
51"
G – Overall height with trim
Overall height without trim
H – Overall width
Electric wall ovens are not approved for
installation with a plug and receptacle.
They must be hard wired in accordance with
installation instructions.
26-5/8"
*Depth including door handle is approximately 26-7/10" min. to 26-8/10" max.
Installation Information: Before installing,
consult installation instructions packed with
product for current dimensional data.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
All GE ranges are equipped with
an Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.
Listed by
Underwriters
Laboratories
Specification Created 5/09
320375
Download from Www.Somanuals.com. All Manuals Search And Download.
|