power factor pro manual
harmonics, and clarity you’ve been missing!
shock, do not expose this equipment to rain
or moisture. dangerous high voltages are
present inside the enclosure. do not remove
the covers. Refer servicing to qualified
personnel only. The lightning flash with an
arrowhead symbol, is intended to alert the user
to the presence of un-insulated dangerous
voltage within the product’s enclosure that may
be of sufficient magnitude to constitute a risk of
electric shock.
additionally, the Power factor Pro is the most
comprehensive power conditioner ever created
for the serious musician. furman’s series
Multi-stage Protection Plus (sMP+) guards
your equipment from voltage spikes that can
damage your amplifier or other connected
equipment.
furman’s sMP+ features unparalleled
clamping voltage. While other designs offer
clamping voltages that are well above 330Vpk,
furman’s sMP+ clamps at 188Vpk (133 VaC
rMs) even when tested with multiple 6000Vpk
- 3000 amp surges! and, our pro level over-
voltage auto shutdown circuit assures you will
never see your prized amplifier go up in flames
due to a sustained voltage overload.
i M P o r ta n t s a f e t Y
i n s t r u C t i o n s
(Please read prior to installation)
1. Please read and observe all safety and
operating instructions before installing
your Power factor Pro unit. retain these
instructions for future reference.
the Pf-Pro has a generous 12 amp r.M.s.
capacity, a convenient 20 segment aC
voltmeter, a detachable-locking aC cord,
and (4) aC outlets, all contained in a small
convenient, floor standing package. The PF-
Pro r has the same features except its cord
is not detachable and it has (8) rear outlets
and (1) front panel outlet. it also features
a BnC connector on the rear panel to allow
attachment of any standard gooseneck lamp
(such as furman’s model Gn-i or Gn-led) to
illuminate the rear of your rack.
2. Your Power factor Pro unit should not be
used near water – for example, near a bathtub,
washbowl, kitchen sink, laundry tub, in a wet
basement, near a swimming pool, etc.
3. do not place your Power factor Pro unit
near heat sources such as radiators, heat
registers, stoves, or other appliances that
produce heat.
4. the Power factor Pro should only be
connected to a 120 VaC, 60Hz, 15 amp (“e”
version - 220 VaC, 10 amp) grounded electrical
outlet. do not defeat the ground or change
polarization of the power plug.
5. Pay particular attention to the condition of
the cords and cables at the plugs. to prevent
risk of fire or injury, damaged cords and cables
should be replaced immediately.
s a f e t Y i n f o r M at i o n
to obtain best results from your furman Power
factor Pro Power Conditioner, please be sure
to read this manual carefully before using.
WARNING: to reduce the risk of electrical
2
Download from Www.Somanuals.com. All Manuals Search And Download.
power factor pro manual
6. Clean your Power factor Pro unit with
a damp cloth only. do not use solvents or
abrasive cleaners. never pour liquid on or into
the unit.
the Power factor Pro, offers a 20 segment
led bar-graph meter that displays incoming
voltage between 90 and 128 volts in 2-volt
increments. the normal range voltages are
indicated in green, with moderately and
extremely high or low voltages in yellow and
red respectively. the voltmeter’s accuracy
is ±2 volts. it can easily be recalibrated, if
necessary.
7. Your Power factor Pro unit should be
serviced by qualified service personnel when:
• the power supply cord or the plug has been
frayed or cut.
• Objects have fallen or liquid has spilled into
the unit.
• the unit has been exposed to rain or other
moisture.
• the unit does not appear to operate normally.
• the “Protection oK” indicator is not lit.
• the unit has been dropped, or the enclosure
has been seriously damaged.
the Pf-Pro r features a rear rack BnC
socket which will accept any 12 VaC (0.5a)
gooseneck lamp assembly, (such as the
furman Gn-led or Gn-i). simply slide the
BnC plug over the socket and rotate clockwise
until the connector snaps into the locked
position. the rear rack lamp can be powered
on or off with the rear light power switch
located on the far left of the front panel.
8. Your Power factor Pro unit requires that a
safety ground be present for proper operation.
Any attempt to operate the unit without
a safety ground is considered improper
operation and could invalidate the warranty.
o P e r at i o n
multi-Segment leD Voltmeter:
this three-color, 20-led bargraph is an
accurate, self checking aC voltmeter that
continually measures input voltages. the
meter reads from 90 to 128 volts in 2 volt
steps (Power factor Pro e: 180 to 256 volts,
in 4 volt steps). the normal range voltages
are indicated in green, with moderate and
extremely high or low voltages in yellow and
red respectively. the voltmeter provides three
special flashing patterns to indicate abnormal
conditions.
9. do not attempt to service your Power factor
Pro unit beyond what is described in this
manual. all other servicing should be referred
to qualified service personnel.
f e a t u r e s
the Power factor Pro has a master switch for
the rear outlets that glows red when the power
is on. The circuit breaker is located adjacent to
the power switch for the Pf-Pro and on the rear
panel for the Pf-Pro r. it can be quickly and
easily reset should the unit be overloaded. the
Pf-Pro also features a detachable 10 foot, 14
gauge heavy-duty power cable.
(1) on initial turn on, the voltmeter will
scan for smart chip integrity.
(2) if only the single leftmost (beneath
the 90V mark) LED flashes, the input
voltage is marginally low.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
power factor pro manual
(3) if all of the leds on the voltmeter
flash, the input voltage is marginally
high. Power to the Power factor
Pro’s outlets will remain on unless the
incoming voltage rises above the
extreme Voltage shutdown (eVs)
cut-off voltage (135 - 140 volts).
to the “on” position.
extreme Voltage Shutdown (eVS) Indicator:
this led is normally off. it monitors a hazard
unfortunately common in the entertainment
industry: wiring faults – for example, accidental
connection to 220VaC where 120VaC is
expected, or an open neutral from a 208 or
240VaC feed. the Power factor Pro’s sMP+
circuit senses voltages that are so high that
operation would be impossible and shuts the
power down before damage can occur. upon
initially applying power to these units, the
extreme Voltage indicator led will be lit if the
input voltage is above the extreme voltage
cutoff, and power will not be applied to the
unit’s outlets. if the unit has been operating
with an acceptable input voltage and then that
voltage goes above 135V, it will shut off power
to the outlet and the extreme Voltage led will
light.
the Power factor Pro’s voltmeter has a basic
accuracy of plus or minus two volts, and
extreme cold or heat may cause an additional
one volt of error (four volts and two volts for
Power factor Pro e).
NOTE: although the Power factor correction
will more than compensate for peak current
demands, the Power factor Pro does not
compensate for sustained high or low line
voltage. if you derive power from generators,
travel internationally, or are in an area prone
to extreme brownouts, you may benefit from
the use of one of furman’s aC line Voltage
regulators.
note: if the mains power is above the high
cutoff voltage and has caused the unit to
remove power from its outlets, it cannot restore
power without the operator manually turning
the unit off, then on again. avoid turning the
unit back on without checking the source of the
on/off rocker Switch:
this 15 amp capacity power switch is
specifically designed to stand up to the
enormous high inrush current demands placed
by many instrument amplifiers. Additionally, the problem first, and perhaps changing the AC
semi-transparent rocker lights when switched source.
Mains Vltg. Voltage Status
Voltmeter Reading
Outlets
80-90
Low Marginal
low
Medium low
normal
Medium High
High
High Marginal
The 90V LED mark flashes
Meter reads in low red
Meter reads in low Yellow
Meter reads in Green
Meter reads in High Yellow
Meter reads in High red
all Meter leds flash
ON
on
on
on
on
on
on
90-104
106-108
110-120
122-124
126-128
130-140
above 140
extreme (shutdown)
Meter off—extreme Voltage led illuminates off
4
Download from Www.Somanuals.com. All Manuals Search And Download.
power factor pro manual
trouBle-sHootinG Guide tHree Year liMited
WarrantY
1.) Symptom: no power to the aC outlets.
furman sound, llC., having its principal place
of business at 1997 south Mcdowell Blvd.,
Petaluma, Ca 94954 (“Manufacturer”) warrants
its Pf-Pro and Pf-Pro r (the “Product”) as
follows:
possible cause: Circuit breaker has
tripped due to excessive load.
action needed: remove one piece of
equipment from the Power factor Pro unit,
and push the square re-set tab into the circuit
breaker bezel.
Manufacturer warrants to the original
Purchaser of the Product that the Product sold
hereunder will be free from defects in material
and workmanship for a period of three years
from the date of purchase. the Purchaser
of the product is allowed fifteen days from
the date of purchase to complete warranty
registration by mail or on-line at the furman
website. if the Product does not conform to this
limited Warranty during the warranty period
(as herein above specified), Purchaser shall
notify Manufacturer in writing of the claimed
defects. if the defects are of such type and
nature as to be covered by this warranty,
Manufacturer shall authorize Purchaser to
return the Product to the furman factory
or to an authorized furman repair location.
Warranty claims should be accompanied by a
copy of the original purchase invoice showing
the purchase date; this is not necessary if the
Warranty registration was completed either via
the mailed in warranty card or on-line website
registration. shipping charges to the furman
factory or to an authorized repair location must
be prepaid by the Purchaser of the product.
Manufacturer shall, at its own expense, furnish
a replacement Product or, at Manufacturer’s
option, repair the defective Product. return
shipping charges back to Purchaser will be
paid by Manufacturer.
2.) Symptom: no power to the aC outlets,
“Protection oK” indicator is not lit.
possible cause: either the aC outlet that
your Power factor Pro device is connected
to has no aC voltage present, or the unit has
been subjected to a sustained voltage in
excess of 400 volts.
action needed: Plug the Power factor
Pro unit into an aC receptacle where aC
voltage is present. if the problem persists, the
protection circuit may be damaged factory
service may be required.
3.) Symptom: extreme Voltage indicator lit.
possible cause: input voltage is above
135 - 140 volts, causing power to the unit’s
outlets to be shut down. additionally, if the
voltage is below 85-90 volts at turn on, the unit
will not allow aC voltage to reach the outlets.
action needed: Correct the line voltage.
then turn the unit on. Consider installing a
furman voltage regulator.
tHe foreGoinG is in lieu of all
otHer Warranties, eXPress or
iMPlied, inCludinG But not liMited
5
Download from Www.Somanuals.com. All Manuals Search And Download.
power factor pro manual
to tHe iMPlied Warranties of
s e r V i C e
MerCHantaBilitY and fitness for
a PartiCular PurPose. Manufacturer
does not warrant against damages or defects
arising out of improper or abnormal use of
handling of the Product; against defects or
damages arising from improper installation,
against defects in products or components
not manufactured by Manufacturer, or against
damages resulting from such non-Manufacturer
made products or components. this warranty
shall be cancelable by Manufacturer at its
sole discretion if the product is modified in
any way without written authorization from
furman sound. this warranty also does not
apply to Products upon which repairs have
been affected or attempted by persons other
than pursuant to written authorization by
Manufacturer.
Before returning any equipment for repair,
please be sure that it is adequately packed and
cushioned against damage in shipment, and
that it is insured. We suggest that you save
the original packaging and use it to ship the
product for servicing. also, please enclose a
note giving your name, address, phone number
and a description of the problem.
note: all equipment being returned for
repair must have a return authorization (ra)
number. to get an ra number, please call the
furman service department: (707) 763-1010,
ext. 121. Please display your ra number
prominently on the front of all packages.
tHis WarrantY is eXClusiVe. the sole
and exclusive obligation of Manufacturer shall
be to repair or replace the defective Product
in the manner and for the period provided
above. Manufacturer shall not have any other
obligation with respect to the Products or
any part thereof, whether based on contract,
tort, strict liability or otherwise. under no
circumstances, whether based on this limited
Warranty or otherwise, shall Manufacturer be
liable for incidental, special, or consequential
damages. Manufacturer’s employees or
representatives’ oral or otHer Written
stateMents do not Constitute
Warranties, shall not be relied upon by
Purchaser, and are not a part of the contract
for sale or this limited warranty. this limited
Warranty states the entire obligation of
Manufacturer with respect to the Product. if
any part of this limited Warranty is determined
to be void or illegal, the remainder shall remain
in full force and effect.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Importantnote:
The Power Factor Pro must be the first AC power component connected to the AC mains!
regulators such as the furman ar-1215 or uPs systems such as the sB-1000 must be
connected to the Power factor Pro’s output. this is due to the fact that the Pf-Pro’s current
reservoir may hinder the performance of a regulator, and worst case may cause damage in
extreme power environments.
as long as the Power factor Pro is connected prior to the regulator or uPs both components
may be used.
SpecIfIcatIonS
Current rating:
noise attenuation:
12 amps (“e” versions 7 amps)
40 dB @ 10 kHz
40 dB @ 100 kHz
100 dB @ 10 MHz
linear attenuation curve from 0.05 - 100 ohms line
impedance
operating Voltage:
90 to 140 VaC (“e” versions 180 to 280 VaC)
over Voltage shutdown:
140 VaC typically (“e” versions 280 VaC typically)
transient Current reservoir:
45 amps peak
Voltmeter accuracy:
±2 VAC, calibrated with internal trimpot adjustments
Mechanical:
spike Protection Modes:
dimensions:
line to neutral, zero ground leakage
Pf-Pro: 5.25” H (with feet) x 8.125” W x 12.5” d.
Pf-Pro r: 19 “ W x 11.63” d x 1.75” H
Weight: Pf-Pro: 11 lbs (5 kg). Pf-Pro r: 9.7 lbs (4.39 kg)
spike Clamping Voltage:
188 Vpk @ 3,000 amps (133 VaC rMs) (tested to
ul-1449 6,000 Vpk @ 3,000 amps)
Power Consumption:
6 watts (resistive)
response time:
1 nanosecond
420 watts (reactive)
safety agency listings:
Maximum surge current:
6,500 amps
Ce, etl-C (pending)
furman sound, llC.
1997 south Mcdowell Blvd.
Petaluma, California 94954-6919 usa
Phone: 707-763-1010
fax: 707-763-1310
Web: www.furmansound.com
e-mail: info@furmansound.com
121304-E