AIll nabosuttthae llation
of your
Split Type Room Air Conditioner
Model(indoor/outdoor):
FRS09PYW1/FRS09PYC1
FRS12PYW1/FRS12PYC1
FRS184YW2/FRS184YC2
FRS18PYW2/FRS18PYC2
FRS224YW2/FRS224YC2
FRS22PYW2/FRS22PYC2
Download from Www.Somanuals.com. All Manuals Search And Download.
To prevent injury to the user or other people and property damage, the
following instructions must be followed.
Incorrect operation due to ignoring of instructions may cause harm or
damage. The seriousness is classified by the following indications.
1. Connect with the power properly.
Otherwise, it may cause electric
shock or fire due to excess heat
generation.
2. Always ensure effective grounding.
No grounding may cause electric
shock.
3. Disconnect the power if strange
sounds, smell, or smoke comes
from it. It may cause fire and
electric shock.
4. Do not operate or stop the unit by
switching on or off the power. It
may cause electric shock or fire due
to heat generation.
5. Do not operate with wet hands or in
damp environment. It may cause
electric shock.
6. Do not allow water to run into
electric parts. It may cause failure of
machine, electric shock or fire.
7. Do not use the power cord near
flammable gas or combustibles,
such as gasoline, benzene, thinner,
etc. It may cause an explosion or fire.
9.Do not damage or use an
unspecified power cord. It may
cause electric shock or fire.
10.Do not place heavy object on the
power cord and ensure that the
cord will not be compressed. There
is danger of fire or electric shock.
8. Do not use the power cord close to
heating appliances. It may cause
fire and electric shock.
Safety precautions
Download from Www.Somanuals.com. All Manuals Search And Download.
05
11.Do not open the unit during
operation. It may cause electric
shock or injury.
12.Do not drink water drained
from air conditioner. It contains
contaminants and could make
you sick.
13.Do not disassemble or modify unit.
It may cause failure of appliance
and electric shock.
14.When the air filter is to be
removed, do not touch the metal
parts of the unit. It may cause an
injury.
15.When the unit is to be cleaned,
switch off, and turn off the circuit
breaker. Do not clean unit when
power is on as it may cause fire,
electric shock or injury.
16.Avoid direct exposure of occupants
to air flow.
17.Turn off the main power switch when
not using the unit for a long time.
18.The air conditioner may be dusted
with an oil free cloth, or washed
with a cloth dampened in a solution
of warm water and mild dishwashing
detergent. Rinse thoroughly and wipe
dry. Wring excess water from cloth
before wiping around controls.
20.Always insert the filters securely.
Clean filter once every two weeks.
Operation without filters may
cause failure.
21.Always install circuit breaker and a
dedicated power circuit. No
installation may cause fire and
electric shock.
19.Ensure that the installation bracket of
the outdoor unit will not damage
due to prolonged exposure. If
bracket damages, there will be
concern of damage due to falling
of unit.
22.Do not place obstacles around air-
inlets or inside of air-outlet. It may
cause failure of appliance or
accident.
Safety precautions
Download from Www.Somanuals.com. All Manuals Search And Download.
06
Choosing the installation site
Installation Warnings
1. Carefully read the installation manual before beginning.
2. Follow each step as shown.
3. Observe all local, state and national electric codes. This appliance must be
installed by a qualified licensed HVAC technician in accordance with all
applicable codes. All electrical connections should be performed by a licensed
electrician.
4. Pay attention to danger and safety notices
Precautions for Installation
Installation at the following sites may cause problems. If you must inevitably install
the unit at one of these sites, please consult your local distributor beforehand:
1. Sites with machine oil.
2. Sites with a high concentration of salinity, such as coastal areas.
3. Sites with sulfuric gas, such as hot water springs.
4. Sites with high frequency equipment, such as wireless equipment, welding
machines and medical installations.
5. Sites with flammable gases or volatile material.
6. Sites with special environmental conditions.
7. Laundry rooms.
06
Choosing the installation site
Download from Www.Somanuals.com. All Manuals Search And Download.
07
Indoor Unit
inside wall, always leaving a space of
at least 6" between the top of the
indoor unit and the ceiling.
1. The unit must be installed at a site
that does not obstruct the flow of
air.
2. The site must support the weight of
the indoor unit.
3. The site must be easily accessible
for maintenance and replacement
of the air filter.
4. The site must allow for the
necessary space around the indoor
unit, as shown in the sideward
figure.
5. There should be at least 3 feet (1
meter) between the unit and radio
or television devices. It is ideal
that the unit be installed at the
center.
8. The site must allow for the easy
removal of the connector pipe and
drain hose.
9. The unit must be installed at a site
protected from direct sunlight.
More
than 6"
More
than 6"
More
than 6"
6. It must be far from fire, smoke or
flammable gases.
7.
We recommend the indoor unit to be
installed as high up as possible on the
More
than 1.65'
Outdoor Unit
More
than 1'
More
than 1'
1. The outdoor unit must be
installed at a convenient site
that is not exposed to strong
winds. The site should be dry
and well ventilated.
06
2. The site must support the weight
of the outdoor unit and allow
for vertical installation.
More
than 6.6'
3. There must not be the possibility
of increased noise and vibration
at the site.
More
than 1.65'
4. The unit must be installed at a
site where the noise produced
6. The site must provide enough
space around the unit, as shown
in the figure.
by its operation and air
discharge does not disturb the
neighbors or animals.
7. Children must not be able to
access the installation site.
5. The site cannot have any
leakage of flammable gases.
Download from Www.SoCmanuhalso.como. Asll Miannuagls Seatrhch Aend Diownnlosadt. allation site
08
Download from Www.Somanuals.com. All Manuals Search And Download.
1
More than 6"
Indoor unit
3
More than 6"
6
More than 6"
Air filter
4
5
More than 1.65'
More than 1'
A
More
than 1.65'
8
7
6
B
C
Outdoor
unit
More than 6.6'
2
Attention
1. This illustration is for explanation purposes only.
2. Copper tubes must be insulated independently
Parts list
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Indoor unit installation
Installation plates and dimensions
6" or more from
the ceiling
Installation plate
Indoor unit outline
6" or more
from the wall
6" or more
from the wall
Refrigerant pipe
hole (right) Ø 2.56"
Refrigerant pipe
hole (right) Ø 2.56"
3.39"
3.39"
A
<
12000 Btu's
(A:33.31" B:10.83")
6" or more from
the ceiling
Installation plate
A
Indoor unit outline
6" or more
from the wall
6" or more
from the wall
Refrigerant pipe
hole (right) Ø 2.56"
Refrigerant pipe
hole (right) Ø 2.56"
1.58''
1.58''
7.91''
5.31''
=18000 Btu's
(A:36.97" B:11.73")
Download from Www.Somanuals.com. All Manuals Search And Download.
Indoor unit installation
11
6" or more from
the ceiling
Installation plate
A
Indoor unit outline
6" or more
from the wall
6" or more
from the wall
1.97''
1.97''
Refrigerant pipe
hole (right) Ø 2.56"
Refrigerant pipe
hole (right) Ø 2.56"
3.94''
4.88''
=21500 Btu's
(A:39.69" B:12.40")
Fixing the Installation Plate
1. Install the installation plate
horizontally over the structural
parts on the wall using the spaces
indicated on the plate, as shown
in the figures above.
Attention
Fit the Installation Plate and drill holes
in the wall according to the wall
structure and corresponding mounting
points on the installation plate
(Dimensions are in “mm” unless
otherwise stated).
2. In the case of tiled, concrete or
similar walls, create 0.2"
diameter holes. Place anchorage
supports for the appropriate
assembly screws.
Installation plate
3. Fix the installation plate to the
wall with eight A type screws.
4. At all times securing to the wall
studs is recommended.
Drilling the Hole
Wall
1. Determine the position of the
hole for the pipes using the
installation plate and drill the
pipe hole so that it is tilted slightly
downward.
Indoor unit
Outdoor unit
2. Always use a pipe cover with an
opening when drilling.
Download from Www.Somanuals.com. All Manuals Search And Download.
Indoor unit installation
12
Connective pipe and drainage installation
Connective pipe
Pipe cover
(right)
Pipe
holder
Pipe cover
(left)
1. For the left-hand and right-hand
piping, remove the pipe cover from
the side panel.
The pipe cover
Left piping
must be kept as it may be used
when relocating the air
to any other place.
conditioner
Rear left
piping
Rear right
piping
Right piping
2. For the rear-right-hand and rear-left-
hand piping, install the piping as
shown in the sideward figure. Bend
the connective pipe to be laid at
a height of 1.69" or less from
Connective
pipe
Indoor unit
outline
Fix the end of the
the wall.
connective pipe.
Drainage
Do not block
water flow
by a rise.
Do not block
water flow
by a rise.
1. Run the drain hose sloping
downward. Do not install the drain
hose as illustrated sideward.
2. When connecting extension drain
hose, insulate the connecting part
of extension drain hose with a
shield pipe, do not let the drain
hose slack.
Do not put the end
of drain hose into water.
Fastening the Indoor Unit
Upper hook
1. Pass the piping through the hole in
the wall.
2. Put the upper claw at the back of
the indoor unit on the upper hook of
the installation plate, move the
indoor unit from side to side to see
that it is securely hooked.
Lower hook
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Indoor unit installation
3. Piping can easily be made by
lifting the indoor unit with a
cushioning material between the
indoor unit and the wall. Get it
out after finish piping.
4. Push the lower part of the indoor
unit up on the wall, Then move
the indoor unit from side to side,
up and down to check if it is
hooked securely.
Cushioning
material
Piping and wrapping
Ponding
box
1. Bundle the tubing, connecting
cable, and drain hose with tape
securely and evenly as shown
in the sideward figure.
Indoor unit
Cable
connection
Pipe room
2. Because the condensed water
from rear of the indoor unit is
gathered in ponding box and is
piped out of room, do not put
anything else in the box.
Connective
pipe
Wrapping
belt
Drain hose
Attention
1. Connect the indoor unit first, then the outdoor unit.
2. Do not allow the piping to let out from the back of the indoor unit.
3. Be careful not to let the drain hose slack.
4. Both of the auxiliary piping should be heat insulation.
5. Be sure that the drain hose is located at the lowest side of the bundle. Locating
at the upper side may cause drain pan to overflow inside the unit.
6. Never intercross nor intertwist the power wire with any other wiring.
7. Run the drain hose sloped downward to drain out the condensed water
smoothly.
Download from Www.Somanuals.com. All Manuals Search And Download.
Indoor unit installation
14
Outdoor unit installation
1. Install the outdoor part of the unit
on a rigid surface to avoid excess
noise and vibration.
2. Direct the air vent toward an area
without obstacles.
3. Install the unit at the site where it is
to as little wind as possible,
exposed
especially in areas where it is
frequently windy.
4. If the installation site is exposed to
heavy winds, such as in coastal
areas, place the unit along the
widest part of the wall or use
protective plates.
5. Be sure there is no obstacle which
blocks radiating air, including
schrubs or bushes.
Strong wind
Outdoor uniDtowinlnoadsfrotmaWwlwl.aSomtainuoalsn.com. All Manuals Search And Download.
15
$
Air inlet
Settlement of outdoor unit
Anchor the outdoor unit tightly and
horizontally on a concrete or rigid
mount with a bolt and nut 0.39" or
0.32" diameter (Purchased separately).
Air
inlet
ꢀ
%
Air outlet
ꢀAꢁft)
B( ft)
Outdoor unit dimension ft(WxHxD)
ꢀꢁꢊꢉꢃ[ꢆꢁꢊꢊꢃ[ꢆꢁꢅꢇꢃ
1ꢀꢊꢊ'
ꢆꢁꢉꢈꢃ
ꢀꢁꢅꢅꢃ
ꢅꢁꢂꢈꢃ
ꢆꢁꢆꢉꢃ
ꢆꢁꢀꢉ'
ꢀꢁꢂꢀꢃ[ꢀꢁꢄꢅꢃ[ꢆꢁꢄꢅꢃ
ꢄꢁꢅꢀꢃ[ꢀꢁꢇꢂꢃ[ꢆꢁꢈꢅꢃ
Condensate drainage of outdoor unit
(no for cooling only)
The condensate and defrosting water formd during heating
in the outdoor unit can be properly discharged by drainage
pipe .
Installation method:Insert the drain connection into one of the
Ø
25 holes of the chassis and then connect drainage pipe with
drain nozzle. Insert drainage plugs into the other holes
(Only for 12000Btu's).
<
ꢆꢉꢅꢅꢅꢋ%WXꢃV
12000 Btu's
Drain
connection
Chassis
Drain
connection
Chassis
Drainage
Plug
Outdoor unit installation
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Refrigerant piping connection
Unit comes with 16.4' tubing bundle. It is not recommended to cut. If too long,
loop for excess.
Note: Keep original bend so not kinking of the tube occurs.
Flaring work
Main cause for refrigerant leakage is
due to defect in the flaring work.
Pipe
Carry out correct flaring work using the
following procedure:
1. Cut the pipes and the cable.
A) Use the piping kit accessory or
pipes purchased locally.
Wrong
Correct
Oblique Roughness Burr
B) Measure the distance between the
indoor and the outdoor unit.
C) Cut the pipes a little longer than the
measured distance.
D) Cut the cable 4.9ft longer than the
pipe length.
2. Burr removal
Pipe
A) Completely remove all burrs from
the cut cross section of pipe/tube.
Reamer
Point
down
B) Put the end of the copper
tube/pipe in a downward direction
as you remove burrs in order to
avoid dropping burrs into the
tubing.
Flare nut
3. Put nut on.
Remove flare nuts attached to
indoor and outdoor unit, then put
them on pipe/tube having
completed burr removal.(It is not
possible to put them on after flaring
work)
Cooper tube
17
Refrigerant piping connection
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Flaring work.
Firmly hold copper pipe in a
die in the dimension shown in
the table below.
Bar
Copper
pipe
Handle
A (inch)
OUTER
Yoke
Red arrow mark
DIAMETER (inch)
Min.
Max.
0.051
0.063
0.071
0.095
0.028
0.039
0.039
0.087
1/4
3/8
1/2
5/8
Clamp
handle
Connection Adjustment
1. Align the pipes to be connected.
Caution: Excessive twisting may
break the nut, depending on the
installation conditions.
2. Screw the flare nut with your
fingers, and then tighten it with
a spanner and torque wrench,
as shown in the following figure.
Pipings
Indoor unit
tubing
Flare
nut
OUTER
DIAMETER (inch)
TIGHTENING
.
TORQUE (lbf in)
ADDITIONAL TIGHTENING
.
TORQUE (lbf in)
1/4
3/8
1/2
5/8
139
260
434
651
174
304
477
694
18
Refrigerant piping connection
Download from Www.Somanuals.com. All Manuals Search And Download.
Power voltage should meet the
requirements in the following
table.
3. Over current protection and circuit
disconnect should meet the
requirements in the following table
and the applicable local and national
electrical codes.
Electrical Data Table
Outdoor Fan
System
Voltage
Volts-Ph.-
Freq
Operating
Voltage
Compressor
Indoor Fan
FLA HP
Max. Fuse/Circuit
Breaker
MIN. Circuit
Ampacity
(MCA)
Capacity
(BTU)
Output
Watts
Output
Watts
Amps(MOCP)
(Min/Max) RLA
LRA
FLA
HP
Volts
ǂ
9K
115-1-60 103/127 16.03
ǂ
26
26
41
41
0.17
0.17
0.62
0.9
0.04
0.04
0.08
0.12
30
30
60
90
115V-AC
115V-AC
0.38
0.38
0.03
0.03
0.03
0.05
20
20
20
35
22
23
16
16
35
40
25
25
12K
18K
115-1-60 103/127 17.53
ǂ
208/230-1-60 187/253 11.54
ǂ
208/230V-AC 0.25
208/230V-AC 0.45
21.5K 208/230-1-60
11.71
187/253
Connecting (Power and Control Cable)
The main power is supplied to the outdoor unit. The field supplied connecting cable from the outdoor unit to indoor unit consists of four
wires and provides the power for the indoor unit as well as the communication signal and ground between the outdoor and indoor unit.
Two wires are high voltage AC power, one is low voltage DC signal and one is a ground wire.
Consult local building codes, NEC (National Electrical Code) or CEC (Canadian Electrical Code) for special requirements.
Download from Www.Somanuals.com. All Manuals Search And Download.
Connect the cable to the indoor unit
Electrical box
cover
1. The inside and outside connecting
cable can be connected without
removing the front grille.
2. Connecting cable between indoor
unit and outdoor unit shall be
approved polychloroprene
sheathed flexible cord, type
designation 16AWG or heavier
cord.
3. Lift the indoor unit panel up,
remove the electrical box cover by
loosening the screw.
4. Ensure the colour of wires of
outdoor unit and the terminal Nos.
are the same to the indoors
respectively.
5. Wrap those cables not connected
with terminals with insulation
tapes, so that they will not touch
any electrical components. Secure
the cable onto the control board
with the cord clamp.
Terminal block of indoor unit
Cable
Code wire
N(1) 2
3
1.57"
0.39"
To Outdoor Unit
20
Download from Www.Somanuals.com. All Manuals Search And DoEwnlloaed. ctrical work
1.
Download from Www.Somanuals.com. All Manuals Search And Download.
Caution
After the confirmation of the above conditions, prepare the wiring as follows:
1. Never fail to have an individual power circuit specifically for the air
conditioner. As for the method of wiring, be guided by the circuit diagram
posted on the inside of control cover.
2. The screws which fasten the wiring in the casing of electrical fittings are
liable to come loose from vibrations to which the unit is subjected during
the course of transportation. Check them and make sure that they are all
tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3. Specification of power source.
4. Confirm that electrical capacity is sufficient.
5. See to that the starting voltage is maintained at more than 90 percent of
the rated voltage marked on the name plate.
6. Confirm that the cable thickness is as specified in the power source
specification.
7. Always install an earth leakage circuit breaker in a wet or moist area.
8. The following would be caused by voltage drop: vibration of a magnetic
switch, which will damage the contact point, fuse breaking, disturbance of
the normal function of the overload protector.
9. The means for disconnection from a power supply shall be incorporated
in the fixed wiring and have an air gap contact separation of at least 1/8 inch
in each active (phase) conductors.
Air purging
Air and moisture in the refrigeration system have undesirable effects as indicated
below:
1. Pressure in the system rises.
2. Operating current rises.
5. Water may lead to corrosion of
parts in the refrigeration system.
Therefore, the indoor unit and tubing
between the indoor and outdoor unit
must apply leakage test and be evacuated
to remove any noncondensables and
moisture from the system.
3. Cooling or heating(only for
models with heating function)
efficiency drops.
4. Moisture in the refrigerant circuit
may freeze and block capillary
tubing.
Electrical work and air purging
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Air purging with vacuum pump
1. Check that each tube(both liquid and gas side tubes) between the indoor and
outdoor units have been properly connected and all wiring for the test run has
been completed. Remove the service valve caps from both the gas and the
liquid side on the outdoor unit. Note that both the liquid and the gas side
service valves on the outdoor unit are kept closed at this stage.
2. When relocating the unit to another place, perform evacuation using vacuum
pump.
3. Pipe length and refrigerant amount:
Air
purging
Additional amount of
refrigerant to be charged
Connective
pipe length
Less than 25'
Use vacuum pump.
Use vacuum pump.
R410a: 0.32ozs/ft (Pipe length-25')
'
25'~65.6
<
( 12000Btu's)
R410a: 0.22ozs/ft (Pipe length-25')
(=18000Btu's)
Use vacuum pump.
25'~98.4'
R410a: 0.32ozs/ft (Pipe length-25')
(=21500Btu's)
Caution in handling the packed valve integrated in the outlets of
outdoor unit.
1. Operation of opening packed valve: Open the valve stem until it hits against
the stopper. Do not try to open it further.
2. Operation of closing packed valve: Securely tighten the valve stem with a special
tool. Then securely tighten the valve stem cap with a spanner or the like. Refer to
tightening torque table in page 17 for valve stem cap tightening torque
Note: There is a charging port integrated in the low side outlet, but not in the
high side outlet. The low side outlet is shown in the sketch map below.
Flare nut
Refrigerant
Valve body
Outdoor unit
Indoor unit
Gas
A
C
Cap
D
Charge port
B
Packed valve
Valve stem
Stopper
Half union
23
Air purging
Download from Www.Somanuals.com. All Manuals Search And Download.
When using the vacuum pump
For method of using a manifold valve, refer to its operation manual.
Indoor unit
1. Completely tighten the flare nuts at
connection point A, B, C and D.
Connect valve core removal tool to
the charging port, then connect
vacuum hose to valve core tool.
Open the schrader valve.
Outdoor unit
Note: The schrader valve is inside
the charging port.
2. Connect the other charge hose of
manifold valve to the vacuum pump.
3. Fully open the handle Lo of the
manifold valve.
Manifold valve
-76cm/Hg
Charge
hose
4. Operate the vacuum pump to
evacuate. After starting evacuation,
slightly loose the flare nut of the
Lo valve on the gas pipe side and
check if the air is entering (Operation
noise of the vacuum pump changes
and a compound meter indicates
0 instead of minus), then tighten
the flare nut. The procedure verifies
if there are blocks inside the tubes.
Handle Hi
Handle Lo
Charge hose
Vacuum pump
5. Make evacuation for 15 minutes
or more and check that the
compound meter indicates
display in the pressure indicator is
a little higher than the atmosphere
pressure. This procedure verifies if
the refrigerant goes through the
tubes correctly.
5
-7.6 x 10 MicronsHg (-1x10 Pa).
After the evacuation is completed,
fully close the handle Lo of the
manifold valve and stop the
7. Close the schrader valve, then
remove the valve core tool.
operation of the vacuum pump.
Replace the charging port cap.
6. Turn the stem of the packed
8. Fully open the packed valve
valve B about 45o
stems B and A.
9. Securely tighten the cap of the
packed valve.
counterclockwise for 6~7
seconds after the gas comes
out, then tighten the flare nut
again. Make sure the pressure
Air purging
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical safety
Perform the electric safety check after completing installation:
1. Insulated resistance: The insulated resistance must be more than 2M .
2. Grounding work: After finishing grounding work, measure the grounding
resistance by visual detection and grounding resistance tester. Make sure the
grounding resistance is less than 4 .
3. Electrical leakage check (performing during test running): During test operation
after finishing installation, the serviceman can use the electric probe and
multimeter to perform the electrical leakage check. Turn off the unit
immediately if electrical leakage happens. Check and find out the solution
ways till the unit operates properly.
Gas leak check
Soap water method
indoor unit
Apply a soap water or a liquid neutral
check point
detergent on the indoor unit
connection or outdoor unit connections
by a soft brush to check for leakage of
the connecting points of the piping. If
bubbles come out, the pipes have
leakage point.
Cover
Outdoor unit
check point
Leak detector
Use the leak detector to check for
leakage.
Caution
A: Lo packed valve, B: Hi packed valve
C and D are ends of indoor unit
connection.
25
Electrical safDeowtnyload afromnWwdw.Sogmaanuasls.colme. AllaMaknualscSeharceh AcndkDownload.
Test running
Perform test operation after completing gas leak check at the flare nut
connections and electrical safety check.
1. Connect the power, press the ON/OFF button on the remote controller to
turn the unit on.
2. Use the MODE button to select COOL, HEAT(Only for models with heating
function), AUTO and FAN to check if all the functions work well.
3. When the ambient temperature is too low(lower than 63 F), the unit
o
cannot be controlled by the remote controller to run in cooling mode,
manual operation can be taken. Manual operation is used only when the
remote controller is disable or maintenance necessary.
Auto/OFF
Manual control button
26
Test running
Download from Www.Somanuals.com. All Manuals Search And Download.
Preparing the device for operation
1. Contact a specialist to install the device.
2. Guarantee that the unit is appropriately fastened and complies with all of
the aforementioned safety norms.
3. Before operating the air conditioner, ensure that the air filter is installed
correctly.
4. If the unit has been out of use for a long period of time, it is recommended
that the air filter be cleaned before use. During continuous use, clean the air
filter every two weeks.
5. This air conditioner was designed for use under the following conditions:
MODE
*
Cool
Heat
Temperature
Indoor Outdoor
41°F~115°F 61°F~86°F 5°F~75°F
Dehumidifier
Temperature
Temperature
Indoor
Outdoor
Indoor
Outdoor
61°F~86°F
61°F~86°F 41°F~115°F
only for models with heating function
*
Attention
If air conditioner is used outside of the above conditions, certain safety protection
features may come into operation and cause the unit to function abnormally.
Room relative humidity should be less than 80%. If the air conditioner operates in
excess of this figure, the surface of the air conditioner may attract condensation.
Please set the horizontal louver to its maximum angle (vertically to the floor), and
set HIGH fan mode.
Optimum performance will be achieved within these operating temperature.
27
Preparing the device for operation