User’s Manual
FOX HD-SDI
Multi-Rate SDI Fiber Optic Transceiver
Extron Electronics, USA
1230 South Lewis Street
Anaheim, CA 92805
800.633.9876 714.491.1500
FAX 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C
3821 AH Amersfoort, The Netherlands
+800.3987.6673 +31.33.453.4040
FAX +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Rd. #04-01
PM Industrial Bldg., Singapore 368363
+800.7339.8766 +65.6383.4400
FAX +65.6383.4664
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
68-1384-01 Rev. A
11 07
+81.3.3511.7655 FAX +81.3.3511.7656
© 2007 Extron Electronics. All rights reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
警告
安全须知 • 中文
这个符号提示用户该设备用户手册中
电源 • 该 设 备 只 能 使 用 产 品 上 标 明 的 电 源 。 设 备
必 须 使 用 有 地 线 的 供 电 系 统 供 电 。 第 三 条 线
( 地 线 ) 是 安 全 设 施 , 不 能 不 用 或 跳 过 。
拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后
或桌面电源的电源线,或任何接到市电系统的电源线。
电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。
维护 • 所有维修必须由认证的维修人员进行。 设备内部没
有用户可以更换的零件。为避免出现触电危险不要自己
试图打开设备盖子维修该设备。
有重要的操作和维护说明。
这个符号警告用户该设备机壳内有暴
露的危险电压,有触电危险。
注意
阅读说明书 • 用 户 使 用 该 设 备 前 必 须 阅 读 并 理
解 所 有 安 全 和 使 用 说 明 。
通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止
机内敏感元件过热。 不要用任何东西挡住通风孔。
锂电池 • 不正确的更换电池会有爆炸的危险。 必须使用与
厂家推荐的相同或相近型号的电池。 按照生产厂的建
议处理废弃电池。
保存说明书 • 用户应保存安全说明书以备将来使
用。
遵守警告 • 用户应遵守产品和用户指南上的所有安
全和操作说明。
避免追加 • 不要使用该产品厂商没有推荐的工具或
追加设备,以避免危险。
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. The Class A limits are designed to
provide reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference, in which case the user will be required to correct the interference at his
own expense.
This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used
with the unit to ensure compliance with FCC emissions limits.
N
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Start Guide — FOX HD-SDI
The FOX HD-SDI is a transceiver that can function as a
transmitter and/or a receiver. At least two units are required
for a transmitter-receiver system with at least one fiber optic
cable linking each two units. The FOX HD-SDI is available in
single mode or multimode versions.
N
Connect and operate two or more FOX HD-SDI units as follows:
Step 1
Power off all equipment. If desired, mount the units in racks.
Step 2
MODE
MODE
MODE
Use the rear panel
1 down
2 down
1 down
2 up
1 up
2 down
Mode DIP switches
to configure each
unit to be installed
in the system as
a bidirectional
1
2
1
2
1
2
Bidirectional
Transceiver
Transmitter
Receiver with
Loop-through
transceiver, a transmitter, or a receiver as shown above right.
The drawings below and on QS-2 show the signal flow for
the three different FOX HD-SDI configurations. For more
information on the various modes and their capabilities, see
"Transceiver configurations" in chapter 1, "Introduction".
N
Step 3
Transmitting unit — Connect an HD-SDI, SDI, or 3G-SDI
video source to the unit's HD/SDI In BNC connector.
HD/SDI IN
Step 4
Video
Source
Transmitting unit —
If the FOX HD-SDI
Video from
Source
To Receiver
is configured as a
FOX HDSDI
OPTICAL
POWER
12V
0.3A MAX
transmitter, and if desired,
connect one or two local
monitors to the unit's
Buffered Outputs BNC
connectors. These two
BNCs output the same
MODE
1
2
HD/SDI IN
BUFFERED OUTPUTS
Tx
Rx
Transmitter
HD-SDI, SDI, or 3G-SDI video that was input in step 3.
Step 5
Both units — Connect
a fiber cable between
the transmitting unit's
Optical Tx connector
and the receiving unit's Optical Rx connector.
FOX HD-SDI • Quick Start Guide
QS-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Start Guide — FOX HD-SDI, cont’d
Table of Contents
Step 6
Receiving unit — Connect one or two monitors to the unit's Buffered
Outputs BNC connectors.
To/from 2nd Video from 2nd
Video
Unit configured as
bidirectional transceiver —
Both BNCs output
the HD-SDI, SDI, or
3G-SDI video that was
transmitted across the
fiber cable.
Source
Transceiver
Transceiver
FOX HDSDI
OPTICAL
POWER
12V
0.3A MAX
MODE
Features......................................................................................... 1-5
1
2
HD/SDI IN
BUFFERED OUTPUTS
Tx
Rx
Bidirectional
Transceiver
Video from
Transmitter
Source
Daisy-chained
Receiver Transmitter
Unit configured as
receiver — Output 2 BNC
only outputs the
FOX HDSDI
OPTICAL
POWER
12V
0.3A MAX
MODE
transmitted video.
1
2
HD/SDI IN
BUFFERED OUTPUTS
Tx
Rx
Receiver with
Loop-through
Step 7
Receiving unit — If desired, connect a fiber cable between the
receiving unit's Optical Tx connector and another unit's Optical Rx
connector.
Unit configured as bidirectional transceiver — Connect the fiber
cable to the transmitting unit.
Unit configured as a receiver — Connect the fiber cable to another
receiving unit for daisy chaining.
Up to 10 receivers can be daisy-chained in this manner.
N
Step 8
Receiving unit configured as bidirectional transceiver —
Connect a video source to the unit's HD/SDI In BNC connector.
HD/SDI IN
Step 9
Transmitting unit configured as a bidirectional
transceiver — Connect one or two local monitors to the
unit's Buffered Outputs BNC connectors. These two
BNCs output the same video that was input in step 8.
1
2
BUFFERED OUTPUTS
Step 10
68-1384-01.Rev. A
Connect power to all FOX units and to all connected video sources
and displays.
11.07
All trademarks mentioned in this manual are the properties of their respective owners.
FOX HD-SDI • Quick Start Guide
FOX HD-SDI • Table of Contents
QS-2
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
The FOX HD-SDI units output continuous,
invisible light, which may be harmful and
dangerous to the eyes; use with caution.
W
About the FOX HD-SDI
The Extron FOX HD-SDI product family consists of two models
(MM and SM) of high performance digital (HD-SDI, SDI, or
3G-SDI) video fiber optic transceivers. The transmitted signal
can include any audio or unidirectional serial data that is
embedded in the input video.
Do not look into the rear panel fiber optic
cable connectors or into the fiber optic cables,
themselves.
•
All transceivers in the system must be the same model (all
singlemode or all multimode).
N
Plug the attached dust caps into the optical
transceivers when the fiber optic cable is
unplugged.
•
Transceiver configurations
The transceiver can be configured via its rear panel Mode DIP
switches to operate in one of three ways:
About this Manual
This manual contains information about the following Extron
FOX HD-SDI fiber optic transceiver products:
•
•
•
Bidirectional transceiver
Transmitter
Receiver
•
FOX HD-SDI MM, a multimode, long distance
(up to 500 m [1,640']) transceiver
configuration.
N
•
FOX HD-SDI SM, a singlemode, very long distance
(up to 30 km [18.75 miles]) transceiver (figure 1-1)
Daisy Chain Numerous
Receivers
Bidirectional transceiver
In this manual, the term "transceiver" refers to any FOX
HD-SDI; the term "bidirectional transceiver" refers to a
FOX HD-SDI configured as described in this section.
N
HD-SDI Broadcast
Monitors
Although the description below does allow connection of
a FOX HD-SDI configured as transmitter or receiver,
the typical configuration is as shown: two bidirectional
transceivers.
N
T
U
L
P
T
D
A
IC
H
T
X
O
P
O
U
B
IG
F
N
O
C
x
R
x
T
X
I
D
S
12V MA
0.2A
/
D
H
Extron
Up to 30 km (18.75 miles)
on singlemode ꢀber using
SM Model
FOX HD-SDI
Fiber Optic
Transceiver
A FOX HD-SDI that is configured as a bidirectional transceiver
(figure 1-2) inputs digital video on its SDI/HD-SDI Input BNC.
The transceiver converts the video input to a proprietary signal
and transmits the video over a fiber link to another FOX HD-SDI
that is configured as a bidirectional transceiver or as a receiver.
HD-SDI Broadcast
Monitors
S
S
T
U
X
O
L
P
T
D
A
IC
H
T
P
O
F
U
B
IG
F
N
O
C
x
R
x
T
HD-SDI
In From
Source A
HD-SDI
In From
Source B
HD-SDI HD-SDI
Out From Out From
Source B Source B
HD-SDI HD-SDI
Out From Out From
Source A Source A
X
D
S
12V MA
0.2A
/
D
H
Extron
FOX HD-SDI
Fiber Optic
Transceiver
FOX HDSDI
OPTICAL
FOX HDSDI
OPTICAL
POWER
12V
0.3A MAX
POWER
12V
0.3A MAX
MODE
MODE
1
2
1
2
HD/SDI IN
HD/SDI IN
HD-SDI Camera
BUFFERED OUTPUTS
BUFFERED OUTPUTS
Tx
Rx
Tx
Rx
Figure 1-1 — Typical FOX HD-SDI application
FOX HD-SDI
FOX HD-SDI
The two products are physically and functionally identical,
with the exception of the effective range of transmission.
In this manual, the term "FOX HD-SDI" refers to either
product.
N
Configured as bidirectional transceiver
Configured as bidirectional transceiver
Figure 1-2 — Bidirectional transceiver connections
FOX HD-SDI • Introduction
FOX HD-SDI • Introduction
1-2
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction, cont’d
A bidirectional transceiver can also simultaneously receive
a proprietary signal from another transceiver (in any
Features
Extends HD-SDI, SDI, and 3G-SDI signals very long distances
configuration) on its Optical Rx port, convert the proprietary
signal to back to the original format digital video, and output
the video on its own two Buffered Outputs BNC connectors.
over a single fiber — The FOX HD-SDI supports multi-
rate SDI at rates up to 2.97 Gbps, and complies with
SMPTE 259M-C, 292M, 424M, and ITU digital video
standards.
Transmitter and receiver
Video input — When it is configured as a transmitter, the
Although the description below does allow connection of a
FOX HD-SDI configured as a bidirectional transceiver, the
typical configuration is as shown: a transmitter and one or
more receivers.
N
FOX HD-SDI inputs digital video on a BNC connector.
HD-SDI loop-through — The transceiver has two Buffered
SDI/HD-SDI BNC connectors that allows connection of
a local monitor when the transceiver is configured as a
transmitter.
A FOX HD-SDI that is configured as a transmitter (figure 1-3)
inputs digital video on its HD/SDI Input BNC. The transmitter
converts the video input to a proprietary signal and transmits
the video over a fiber link to a FOX HD-SDI that is configured as
a receiver or as a bidirectional transceiver. The transmitter also
simultaneously outputs the digital video on its two Buffered
Outputs BNCs.
Video output — The transceiver outputs digital video on one
or two Buffered SDI/HD-SDI BNC connectors when it is
configured as a bidirectional transceiver or a receiver.
Dual buffered outputs — When the FOX HD-SDI is configured
as a transmitter, the SDI/HD-SDI BNC output connectors
can be used for previewing the video on a local monitor.
FOX HD-SDI(s)
Configured as receiver(s)
Input equalization and reclocking on buffered outputs — The
FOX HD-SDI automatically equalizes incoming multi-
rate SDI signals, and reshapes and restores signals on its
buffered outputs.
HD-SDI
In From
Source A
HD-SDI HD-SDI
Out From Out From
Source A Source A
HD-SDI
Out From
Source A
Transmitted HD-SDI
from source A
FOX HDSDI
OPTICAL
FOX HDSDI
OPTICAL
POWER
12V
0.3A MAX
POWER
12V
0.3A MAX
MODE
MODE
Daisy chain capability — Up to 10 transceivers can be daisy
chained to send the video to multiple locations when one
of more units are configured as receivers.
1
2
1
2
HD/SDI IN
HD/SDI IN
BUFFERED OUTPUTS
BUFFERED OUTPUTS
Tx
Rx
Tx
Rx
Real-time status LED indicators for troubleshooting and
monitoring
FOX HD-SDI
FOX HD-SDI
Configured as transmitter
Configured as receiver
1" high, quarter rack width, metal enclosures — With low
profile enclosures, the transceiver can be discreetly
installed in a variety of locations, such as behind a plasma
or LCD flat-panel display.
Figure 1-3 — Transmitter-to-receiver connections
A FOX HD-SDI that is configured as a receiver receives a
proprietary signal on its Rx fiber optic port. The receiver
converts the proprietary signal back to original HD-SDI, SDI,
or 3G-SDI video and outputs the video on only one of its own
Buffered Output BNC connectors, Output 2.
Rack mountable — The unit is rack mountable in any
conventional 19" wide rack, using any of a variety of
Extron's rack shelves.
Power — The unit's 100 VAC to 240 VAC, external power supply
The receiver converts the second digital video signal that it
created from the optical input back into a proprietary signal
and outputs it on the Optical Rx port over a fiber link to another
FOX HD-SDI that is configured as a receiver or as a bidirectional
transceiver.
provides worldwide power compatibility.
Up to 10 receivers can be daisy-chained in this manner.
N
FOX HD-SDI • Introduction
FOX HD-SDI • Introduction
1-4
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation
Mounting instructions
Mounting the Unit
For optional rack mounting, mount the transceiver on any of the
following rack shelves:
Installation and service must be performed by
authorized personnel only.
C
•
RSF 123 3.5" deep 1U VersaTools® rack shelf kit
(part #60-190-20) (figure 2-1)
The 1" high, quarter-rack width transceiver can be placed on
a tabletop, mounted on a rack shelf, mounted under a desk or
tabletop, or mounted on a projector bracket.
•
•
RSB 123 3.5" deep 1U VersaTools rack shelf (part #60-604-20)
RSU 126 6" deep 1U universal rack shelf kit
(part #60-190-10)
Tabletop placement
Affix the four included rubber feet to the bottom of the unit and
place it in any convenient location.
•
•
RSB 126 6" deep 1U basic rack shelf (part #60-604-10)
RSU 129 9.5" deep 1U universal rack shelf kit
(part #60-190-01) (figure 2-2 on the next page)
Rack mounting
•
RSB 129 9.5" deep 1U basic rack shelf (part #60-604-01)
UL requirements
The following Underwriters Laboratories (UL) requirements
pertain to the installation of the FOX HD-SDI transmitter or
receiver into a rack (figure 2-1).
VersaTools Rack Shelf
1.
Elevated operating ambient temperature — If installed in
a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater
than room ambient. Therefore, consider installing the
equipment in an environment compatible with the +122 °F
(50 °C) maximum ambient temperature (Tma) specified by
Extron.
1/4 Rack Width Front
False Faceplate
2.
3.
4.
Reduced air flow — Installation of the equipment in a rack
should be such that the amount of air flow required for
safe operation of the equipment is not compromised.
Mechanical loading — Mounting of the equipment in
the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
Use 2 mounting holes on
opposite corners.
(2) 4-40 x 3/16"
Screws
Circuit overloading — Consideration should be given to
the connection of the equipment to the supply circuit and
the effect that overloading of the circuits might have on
overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be
used when addressing this concern.
Figure 2-1 — Mounting the transceiver on a
VersaTools rack shelf
On the non-VersaTools rack shelves, the transceiver unit can be
mounted in the front or the rear of the rack.
5.
Reliable earthing (grounding) — Reliable earthing
of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections
other than direct connections to the branch circuit (such as
the use of power strips).
1.
2.
If installed, remove the feet from the bottom of the unit.
Mount the unit on the shelf, using two 4-40 x 3/16" screws
in opposite (diagonal) corners to secure the unit to the
shelf.
3.
4.
Install false faceplate(s) or other unit(s) to the rack shelf.
Insert the shelf into the rack, aligning the holes in the shelf
with those of the rack.
FOX HD-SDI • Installation and Operation
FOX HD-SDI • Installation and Operation
2-2
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
1U Universal Rack Shelf
1/2 Rack Width
Front False
Faceplate
1/4 Rack Width
Front False
Faceplate
Both front false faceplates
use 2 screws.
(2) 4-40 x 3/16"
Screws
Use 2 mounting holes on
opposite corners.
Figure 2-3 — Under-desk mounting
6.
Align the installed screws with the slots in the mounting
brackets, and place the transceiver against the surface,
with the screws through the bracket slots.
Figure 2-2 — Mounting the transceiver on a standard
rack shelf
5.
Secure the shelf to the rack using the supplied machine
screws.
7.
Slide the transceiver slightly forward or back, then tighten
all four screws to fasten it in place.
Furniture mounting
The transceiver can be mounted under a horizontal surface using an
optional MBU 125 under-desk mounting kit (part #70-077-01).
Mount the unit under a desk or table as follows:
1.
2.
If rubber feet were previously installed on the bottom of
the unit, remove them.
Secure the under-desk mounting brackets to the
transceiver with the four machine screws provided in the
mounting kit (figure 2-3).
3.
4.
Hold the transceiver with attached brackets against the
underside of the desk or other furniture. Mark the location
of holes for screws on the desk.
Drill 1/4" (6.4 mm) deep, 3/32" (2 mm) diameter pilot
holes in the table or desk at the marked screw locations
from the underside or inside (the concealed side) of the
furniture, where the transceiver will be located.
5.
Insert the four wood screws into the pilot holes. Fasten
each screw into the installation surface until just less than
1/4" of the screw head protrudes.
FOX HD-SDI • Installation and Operation
FOX HD-SDI • Installation and Operation
2-4
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
c. Tighten the screws.
Through-desk mounting
d. Replace the unit inside the surface (step 4).
The transceiver can be mounted through a desk or other
furniture using an optional Extron MBD 129 through-desk
mounting kit, part #70-077-02. Mount the transceiver through a
desk or table as follows (figure 2-4):
Projector mounting
The transceiver can be mounted on a projector bracket using
either of the following optional Extron projector mounting kits:
•
•
PMK 300 projector mounting kit (part #70-374-01)
PMK 350 low profile projector mounting kit
(part #70-563-02 [black] or part #70-563-03 [white])
PMK 300 mounting
Mount the transceiver to a PMK 300 bracket as follows:
1.
If necessary, remove the feet from the bottom of the
transceiver.
2.
Mount the transceiver to one of the bracket’s three
mounting plates using two of the supplied 4-40 x 3/16"
screws in opposite (diagonal) corners to secure the device
to the bracket. It can be vertically mounted facing either
up or down (figure 2-5).
On the side mounting plates, the device is typically
mounted on the outside of the bracket.
N
On the front mounting plate, the device is typically
mounted on the inside of the bracket.
Figure 2-4 — Through-desk mounting
Side Mounting
Plate
1.
Loosely attach the mounting brackets to the transceiver
using the four machine screws and washers supplied with
the mounting kit.
Bracket
Brace
U-Bolt
2.
Hold the transceiver against the inside of the surface
through which it will be mounted. Mark the four screw
holes on the inside of the surface to which you are
mounting the device.
Extron
FOX 500 HDSDI
Transceiver
Power Supply
3.
4.
5.
Drill four pilot holes, each 3/32" in diameter by 1/4" deep,
where you made marks.
Extron
PMK 300
Multi-product Projector Mount Kit
Using the provided four wood screws, secure the brackets
to the mounting surface.
Front Mounting
Plate
Slide the transceiver up and down in the mounting
brackets until the face of the transmitter or receiver is at
the desired height. Tighten the screws that secure the
brackets in place.
If the screws are inaccessible to a screwdriver:
a. On the transceiver, mark the location of the brackets
relative to the screws.
Figure 2-5 — PMK 300 projector mounting a transceiver
FOX HD-SDI • Installation and Operation
b. Remove the transceiver from inside the furniture.
FOX HD-SDI • Installation and Operation
2-6
2-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
3.
Use the two included tie wraps to strap the power supply
to one of the brackets.
PMK 350 mounting
Mount the transceiver to a PMK 350 bracket as follows:
The PMK 300 has a hole in the bottom plate that allows the
projector pole to be inserted through the center of the plate
(figure 2-6), rather than outside of the plate (figure 2-5).
To install the PMK 300 in this configuration, slide the
bracket up from the bottom of the pole before the projector
is installed on the pole.
N
1.
Remove the front and back plates from the PMK 350
(figure 2-7), using an Extron Tweeker or a #2 Philips
screwdriver. Retain the screws to reattach the plates when
you are finished.
Extron
Quarter-rack
Rear Plate
Sized Product
Bracket
Brace
Contoured
Base
L-shaped
Bracket
Extron
PMK 350
Multi-product Projector
Mounting Kit
U-bolt
Extron
PMK 300
U-Bolt
Multi-product Projector
Mount Kit
Extron
Power Supply
Front Plate
Cover Sheet
Figure 2-7 — PMK 350 projector mounting a
transceiver
2.
3.
If necessary, remove the feet from the bottom of the
receiver.
Secure the transceiver to one side of the mounting tray,
using two of the supplied 4-40 x 3/16" screws in opposite
(diagonal) corners.
Figure 2-6 — Projector pole on the inside
4.
5.
Use the two included tie wraps to strap the power supply
to the bracket.
4.
Place the contoured bracket brace against the pole and
opposite the back plate. The pole should fit snugly into the
depression in the center of the bracket brace.
Place the PMK 350 around the projector ceiling mounting
pole (figure 2-7, above).
5.
Place the U-bolt around the ceiling pole and insert the
two legs of the U-bolt through the round holes on the
contoured bracket brace and then through the slotted holes
on the bracket’s mounting plate.
The supplied U-bolt fits a typical (1.5" to 2.0" diameter)
ceiling pole.
N
6.
Secure the bracket to the U-bolt with the included hex
nuts, washers, and lock washers. Tighten the hex nuts just
enough that they can be loosened by hand.
FOX HD-SDI • Installation and Operation
FOX HD-SDI • Installation and Operation
2-8
2-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
6.
Assemble the U-bolt and the following parts in the
following order (figure 2-8):
Connections and Settings
All connectors are on the rear panel (figure 2-9).
Mount Plate
Flange
FOX HDSDI
OPTICAL
POWER
12V
Contoured
Base
MODE
0.3A MAX
U-bolt
1
2
1
2
HD/SDI IN
BUFFERED OUTPUTS
Tx
Rx
L-shaped
Bracket
5
1
2
3
4
Slotted Hole
in PMK Tray
L-shaped
Bracket Screws
Figure 2-9 — FOX HD-SDI transceiver’s connectors
Ceiling
Pole
HD-SDI Input connector — If the FOX HD-SDI is configured
as either a bidirectional transceiver or as a transmitter, connect
an HD-SDI, SDI, or 3G-SDI video input to this BNC connector.
a
b
Figure 2-8 — Hanging the tray on the pole
Mode switches — Set these DIP switches to the positions shown
in the table below to select the transceiver configuration. See
a. Pass the legs of the U-bolt through the slotted holes on
the mount plate flange.
b. Place the legs around the projector pole.
SW1 SW2 Mode
c. Pass the legs through the holes in the contour base.
Down Down Bidirectional transceiver (default position)
MODE
The pole fits snugly into the depression in the center
of the contoured base.
N
Down Up
Transmitter with local monitor outputs
Down Receiver with daisy chaining
Up
Up
d. Pass the U-bolt legs through the holes in the L-shaped
1
2
Up
Spare (functions as receiver with daisy chaining)
bracket.
The supplied U-bolt fits a typical (1.5" to 2.0"
diameter) ceiling pole.
Fiber optic connectors —
N
c
This unit outputs continuous invisible light, which
may be harmful and dangerous to the eyes; use with
caution. For additional safety, plug the attached
W
7.
Align the two slotted holes in the bottom of the L-shaped
bracket with the two slotted holes in the base of the tray.
Secure the L-shaped bracket to the base by inserting two
provided 6-32 x 5/16" screws through the aligned slots.
dust caps into the optical transceivers
when the fiber optic cable is unplugged.
OPTICAL
8.
9.
Move the PMK 350 up to the desired location on the ceiling
pole, as close to the ceiling as desired.
Ensure that you use the proper fiber cable for
your transceivers. Typically, singlemode fiber
cable has a yellow jacket and multimode fiber
determine the transceiver's compatibility.
N
Tx
Rx
Secure the L-shaped bracket to the U-bolt using the
included hex nuts, washers, and lock washers. Tighten the
hex nuts securely.
Be sure to tighten the hex nuts securely enough that the
PMK 350 does not slide down the ceiling pole. A socket
wrench is recommended to tighten the hex nuts.
N
Tx — In any FOX HD-SDI configuration, for all one-
way HD-SDI, SDI, or 3G-SDI transmission, connect a
fiber optic cable to the Optical Tx LC connector.
10. Secure the front panel to the mounting tray with four of
the included #6 screws.
Connect the free end of this fiber optic cable
to the Optical Rx connector on another
FOX HD-SDI transceiver that is configured as a
bidirectional transceiver or as a receiver.
OPTICAL
11. If desired, choose one of the provided four sizes of self-
adhesive cover sheets, and apply it to the underside of the
mounting tray.
Tx
Rx
FOX HD-SDI • Installation and Operation
FOX HD-SDI • Installation and Operation
2-10
2-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
Rx — If the FOX HD-SDI is configured as a bidirectional
Power supply wiring
transceiver or as a receiver, for one-way communications
from the transmitting unit, connect a fiber optic cable to the
Optical Rx connector.
Figure 2-10 shows how to wire the power connector.
If the FOX HD-SDI is configured as a bidirectional transceiver,
connect the free end of this fiber optic cable to the Optical Tx
connector on the transmitting FOX HD-SDI.
Smooth
Ridges
A
A
SECTION A–A
If the FOX HD-SDI is configured as a receiver, connect the
free end of this fiber optic cable to the Optical Tx connector
on the next FOX HD-SDI in the daisy chain.
Power Supply
Output Cord
Tie Wrap
Buffered Outputs connectors — In any FOX HD-SDI
configuration, connect a digital display to these BNC
more details.
3
5
d
e
Captive Screw
Connector
If the FOX HD-SDI is configured as a bidirectional transceiver,
the video is output on both connectors 1 and 2 and is the video
signal sent from the other transceiver.
Figure 2-10 — Power connector wiring
Power supply voltage polarity is critical. Incorrect
voltage polarity can damage the power supply
and the FOX HD-SDI. Identify the power cord
negative lead by the ridges on the side of the cord
(figure 2-10).
C
If the FOX HD-SDI is configured as a receiver, the video
is output on connector 2 only and is the video sent by the
transmitting unit.
If the FOX HD-SDI is configured as a transmitter, the video is
output on both connectors 1 and 2 and is looped through from
To verify the polarity before connection, plug in the power
supply with no load and check the output with a voltmeter.
the same transceiver's HD/SDI Input connector, item
.
a
Power connector — Plug the included external 12 VDC
power supply into this 2-pole captive screw connector.
See “Power supply wiring”, on the next page, to wire the
connector.
The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before wiring.
W
The length of the exposed (stripped) copper wires
is important. The ideal length is 3/16" (5 mm).
Longer bare wires can short together. Shorter wires
are not as secure in the connectors and could be
pulled out.
C
Do not tin the power supply leads before installing them
in the connector. Tinned wires are not as secure in the
connectors and could be pulled out.
N
Use the supplied tie-wrap to strap the power cord to the
extended tail of the connector.
Alternatively, an optional Extron PS 123 Universal 12 VDC
Power Supply, part #60-814-01, can power multiple Extron
12 VDC devices using only one AC power connector.
FOX HD-SDI • Installation and Operation
FOX HD-SDI • Installation and Operation
2-12
2-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation, cont’d
Operation
System operation
After the transmitting and receiving units and all of their
Front panel indicators
connected devices are powered up, the system is fully
operational. If any problems are encountered, ensure all
traditional and fiber cables are routed and connected properly.
All indicators are on the front panel (figure 2-13).
RATE
270
Mbps
1.485
Gbps
2.97
Gbps
UNKNOWN
FOX HDSDI
1
2
Figure 2-13 — FOX HD-SDI's transceiver’s indicators
Power indicator — When lit, this light emitting diode (LED)
a
b
indicates that the FOX HD-SDI transceiver is receiving power.
Rate indicators — These LEDs light to indicate the detected
input video rate, either on the HD/SDI input BNC (if configured
as a transmitter) or on the Optical Rx connector (if configured as
a receiver or bidirectional transceiver). The recognized rates are
270 Mbps, 1.485 Gbps, or 2.97 Gbps.
When the Rate Unknown LED lights, this indicates that an input
is detected, either on the HD/SDI input BNC (if configured as
a transmitter) or on the Optical Rx connector (if configured as a
receiver or bidirectional transceiver), but that the FOX HD-SDI
does not recognize the rate.
All four Rate LEDs blink repeatedly if a fiber optic
connector module on the rear of the unit is unseated.
N
The FOX HD-SDI equalizes and distributes the input
whether it recognizes the rate or not.
N
Fiber Compatibility Indications
You must use the proper fiber cable for your transceivers.
Each transceiver indicates its fiber compatibility, singlemode or
multimode, at power-up by blinking the four Rate indicators.
• Multimode — The Rate LEDs blink once.
• Singlemode — The Rate LEDs blink twice.
To determine the fiber cable type, observe the cable jacket.
Typically, singlemode fiber cable has a yellow jacket and
multimode fiber cable has an orange jacket.
N
All transceivers in the system must be the same model (all
singlemode or all multimode). Mixed transmission mode
units will not work together.
N
FOX HD-SDI • Installation and Operation
FOX HD-SDI • Installation and Operation
2-14
2-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference Information
Video
Specifications
Signal type...................................... HD-SDI, SDI, and 3G-SDI digital video
The FOX HD-SDI is a transceiver that can function as a
N
signals
transmitter and/or as a receiver. Two units are required for a
transmitter-receiver system with one fiber optic cable linking
the two units. The FOX HD-SDI is available in single mode or
multimode versions.
Gain ................................................ Unity
Resolution....................................... 8 or 10 bits, automatic
Data rates........................................ 270 Mbps, 1.485 Gbps, 2.970 Gbps
Operation standards..................... SMPTE 259M-C, SMPTE 292M,
SMPTE 424M, ITU-R BT.601,
These transceivers are class 1 laser products. They meet the
safety regulations of IEC-60825, FDA 21, CFR 1040.10, and
FDA 21 CFR 1040.11.
N
ITU-R BT.1120, DVB-ASI
Auto data rate lock........................ Yes
Video input— transmitter
Number/signal type..................... 1 single link SDI, HD-SDI, or 3G-SDI
digital component video
Optical fiber interconnection between transmitter and
receiver
Number/type ................................ 1 fiber optic
Connectors .................................... 1 female BNC
Data rates........................................ 19 Mbps to 2.97 Gbps
Nominal level ................................ 0.8 Vp-p
Minimum/maximum levels........ 0.5 V to 1 Vp-p with no offset
Impedance ..................................... 75 ohms
Return loss ..................................... <-15 dB @ 5 MHz to 2.97 GHz
DC offset (max. allowable)........... 5 V
Input coupling............................... AC
Only one fiber is required to transmit video and embedded audio
and unidirectional data.
N
Connectors ..................................... 1 LC connector
Operating distance........................ 30 km (18.75 miles) with singlemode (SM)
cables with a FOX HD-SDI SM
500 m (1640’) with multimode (MM)
cables with a FOX HD-SDI MM
Input cable equalization............... Automatic for up to -30 dB of cable loss
Operating distance is approximate. These are typical
distances. The maximum distance may be greater than these
typical numbers depending on factors such as fiber type, fiber
bandwidth, connector splicing, losses, modal or chromatic
dispersion, environmental factors, and kinks.
N
HD-SDI ............................... 120 m (400’) using Extron RG6 cable
90 m (300’) using Extron RG59 cable
SDI....................................... 150 m (500’) using Extron RG6 cable
120 m (400’) using Extron RG59 cable
The transmission distance varies depending on the signal
resolution and on the type of cable, graphic card, and display
used in the system.
N
Nominal peak wavelength........... 850 nm for FOX HD-SDI MM,
1310 nm for FOX HD-SDI SM
Transmission power
Singlemode......................... -5 dBm, typical
Multimode.......................... -5 dBm, typical
Maximum receiver sensitivity
Singlemode......................... -18 dBm, typical
Multimode.......................... -12 dBm, typical
Optical loss budget
Video output — receiver
Number/signal type..................... 2 single link SDI, HD-SDI, or 3G-SDI
digital component video
Connectors .................................... 2 female BNC
Reclocking...................................... Automatic for 270 Mbps, 1.485 Gbps,
2.97 Gbps, or bypassed for unrecognized
rates
Singlemode......................... 13 dB, maximum
Multimode.......................... 7 dB, maximum
Nominal level ................................ 0.8 Vp-p
Minimum/maximum levels........ 0.5 V to 1.0 Vp-p
Impedance ..................................... 75 ohms
FOX HD-SDI • Reference Information
FOX HD-SDI • Reference Information
A-2
A-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference Information, cont’d
Return loss ..................................... <-25 dB @ 100 MHz
DC offset ........................................ 5 mV with input at 0 offset
Part Numbers
FOX HD-SDI part numbers
General
The FOX HD-SDI is a transceiver that can function as
N
External power supply ................ 100 VAC to 240 VAC, 50/60 Hz, 6 watts,
external; to 12 VDC, 2 A, regulated
Power input requirements........... 12 VDC, 0.3 A
Temperature/humidity................ Storage: -40 to +158 °F (-40 to +70 °C) /
10% to 90%, noncondensing
a transmitter and/or as a receiver. At least two units are
required for a transmitter-receiver system with one fiber
optic cable linking the two units.
Additional transceivers configured as receivers can be
added to the system for daisy-chaining.
Operating: +32 to +122 °F (0 to +50 °C) /
10% to 90%, noncondensing
The FOX HD-SDI is available in singlemode (SM) and
multimode (MM) models:
Cooling ........................................... Convection, unvented
Rack mount.................................... Yes, with optional 1U, 9.5” deep rack shelf,
part #60-190-01 or 60-604-01;
FOX HD-SDI Models
FOX HD-SDI SM
Part number
60-901-01
60-900-01
1U, 6” deep rack shelf, part #60-190-10,
60-604-10;
FOX HD-SDI MM
or VersaTools® 1U, 3” deep rack shelf, part
#60-190-20 or 60-604-20.
Included parts
These items are included in each order for a FOX HD-SDI:
Also furniture mountable with optional
Through-Desk Mounting Kit, #70-077-02,
or Under-Desk Mounting Kit, #70-077-01;
or attachable to a projector mount using
optional kit #70-526-02 or 70-077-04.
Included parts
Replacement
part number
12 VDC power supply
70-055-01
Tweeker (small screwdriver)
User’s guide
Enclosure type .............................. Metal
Enclosure dimensions................... 1.0” H x 4.3” W x 3.0” D
(quarter rack wide)
(1) 10' LC-LC duplex patch cables
(SM or MM, depending on the model)
2.5 cm H x 10.9 cm W x 7.6 cm D
(Depth excludes connectors.)
Product weight .............................. 0.5 lb (0.3 kg) per each unit
Shipping weight ........................... 3 lbs (2 kg) per each unit
Vibration ........................................ ISTA 1A in carton
(International Safe Transit Association)
Listings............................................ UL, CUL
Compliances................................... CE, FCC Class A, VCCI, AS/NZS, ICES,
FDA Class 1
MTBF............................................... 30,000 hours
Warranty ........................................ 3 years parts and labor
All nominal levels are at 10%.
N
N
Specifications are subject to change without notice.
FOX HD-SDI • Reference Information
FOX HD-SDI • Reference Information
A-4
A-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference Information, cont’d
Optional accessories
Accessories
Part number
60-190-01
RSU 129 9.5" 1U universal rack shelf kit
RSB 129 9.5" 1U basic rack shelf
60-604-01
RSU 126 6" deep 1U universal rack shelf kit
RSU 126 6" deep 1U universal rack shelf
60-190-10
60-604-10
60-190-20
RSF 123 3.5" deep 1U VersaTools®
rack shelf kit
RSB 123 3.5" deep 1U VersaTools
rack shelf
60-604-20
MBD 129 through desk mounting kit
PMK 300 projector mounting kit
70-077-02
70-374-01
PMK 350 low profile projector mounting kit,
black (white)
70-563-02 (03)
FOX HD-SDI • Reference Information
A-6
Download from Www.Somanuals.com. All Manuals Search And Download.
|