User’s Manual
HSA 200S & HSA 200SE
HSA 200C & HSA 200CE
HSA 222S & HSA 222C
Hideaw ay Surface Access Products
68-695-01 Re v. H
08 08
© 2008 Extron Electronics. All rights reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Ta b le o f Co n t e n t s
Ch a p t e r 1 • In t ro d u ct io n .......................................................... 1-1
Ab o u t t h e Hid e a w a y Su rfa ce Acce ss Pro d u ct s ....... 1-2
About the Extender board line driver .................................. 1-4
Fe a t u re s ...................................................................................... 1-5
All models .............................................................................. 1-5
HSA 200CE and HSA 200SE models only .............................. 1-5
Ch a p t e r 2 • In st a lla t io n ............................................................. 2-1
In st a lla t io n Ove rvie w .......................................................... 2-2
Pre p a rin g t h e Ro u t in g Te m p la t e ................................... 2-3
Preparing the Table and Mounting the Enclosure ... 2-4
Preparing the table with a router ........................................ 2-4
Preparing the table with a hole saw
(HSA 200C, HSA 200CE, or HSA 222C—US version only) ..... 2-6
Installing the HSA enclosure (all).......................................... 2-6
Un d e rsid e Fe a t u re s a n d Ca b lin g Co n n e ct io n s ....... 2-8
All HSA 200 models only ....................................................... 2-9
HSA 200C and HSA 200S (no Extender board) only ............ 2-9
All HSA 200 and HSA 222 models ....................................... 2-10
HSA 200CE and HSA 200SE (Extender board) only ............ 2-11
Power connector wiring .................................................. 2-12
Fro n t Pa n e l Co n n e ct o rs .................................................... 2-12
Pre -in st a lla t io n Te st in g a n d Tro u b le sh o o t in g
(HSA 200CE a n d HSA 200 SE m o d e ls o n ly) ............. 2-16
If the image does not appear or there is no sound .......... 2-16
If the image is not displayed correctly ............................... 2-16
Ch a p t e r 3 • Ma in t e n a n ce a n d Mo d ifica t io n s ............ 3-1
Re m o vin g a n d Re p la cin g t h e En clo su re .................... 3-2
Re p la cin g t h e Be ze ls ............................................................ 3-3
Re p la cin g t h e Ga s Lift ......................................................... 3-8
Ad ju st in g t h e To p Pa n e l ................................................... 3-13
HSA 200/222 Series • Table of Contents
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Ta b le o f Co n t e n t s, co n t ’d
Ap p e n d ix A • Re fe re n ce In fo rm a t io n ............................ A-1
Sp e cifica t io n s ......................................................................... A-2
HSA Pa rt Nu m b e rs ................................................................ A-7
In clu d e d Pa rt s ......................................................................... A-8
Ro u t in g Te m p la t e s ............................................................... A-8
Re p la ce m e n t Pa rt s ............................................................... A-8
Acce sso rie s ............................................................................... A-8
To p Pla t e Dim e n sio n s ......................................................... A-8
HSA 200/222 Series Surface Access Products
Ap p e n d ix B • Pa cka g in g fo r Sh ip m e n t .......................... B-1
All trademarks mentioned in this manual are the properties of their respective owners.
Chapter One
68-695-01 Re v. H
08 08
1
In t ro d u ct io n
About the Hideaway Surface Access Products
Features
HSA 200/222 Series • Table of Contents
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
The Extron Hideaway HSA 200 series and HSA 222 series are
furniture-mounted, architectural solutions for inconspicuous
computer video and/ or network access and control.
The HSA 200C (figure 1-1) and HSA 200S (figure 1-2) provide:
•
One standard grounded AC receptacle
The US versions have US power receptacles
Fig u re 1-2 — HSA 200S h id e a w a y e n clo su re
The international versions have several different
types of power receptacles available, including
Universal, UK, French, Israeli, Australian, Indian,
European, and Swiss receptacles.
The HSA 222S (figure 1-3) and HSA 222C (US model only)
provide:
•
Two standard grounded AC receptacles
The Universal AC outlet is fully compatible with
Europlug, British, Indian, Danish, and Italian plug
types. See the universal AC outlet guide on the Extron
all plug types.
The US versions have US power receptacles
The international version has several different types
of power receptacles available, including UK, French,
Israeli, Australian, Indian, European, and Swiss
receptacles.
•
Two RJ-45 Category (CAT) 6 connectors (teminated in
•
Two RJ-45 CAT 6 connectors
accordance with the TIA/EIA 568 A standard)
•
•
One 15-pin female HD computer video connector
One 3.5 mm stereo female jack.
Fig u re 1-3 — HSA 222S h id e a w a y e n clo su re
The International HSA 222 is only available with a
square top plate.
For all models, cabling inside the enclosure runs the AC power
line and RJ-45 signal lines from the HSA panel connectors to
connectors on the bottom of the enclosure. For the HSA 200
model, the computer video signal is routed to 5 BNC connectors
on pigtails. On HSA 200S and HSA 200C units, the audio signal
is sent to a 3-pole, 3.5 mm captive screw connector on a pigtail.
On HSA 200SE and HSA 200CE units, the audio signal is sent to
a 5-pole, 3.5 mm captive screw connector on the back of the unit.
Fig u re 1-1 — HSA 200C h id e a w a y e n clo su re
The HSA 200CE and HSA 200SE provide all of the HSA 200C
or HSA 200S features plus:
•
An Extender board, which sends the input signal a
greater distance and converts the audio input to a
balanced signal. See “About the Extender board line
driver”, on the next page, for more details.
HSA 200/222 Series • Introduction
1-2
HSA 200/222 Series • Introduction
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
In t ro d u ct io n
The installed enclosures fit nearly flush within a table or podium
Fe a t u re s
top (figure 1-4), storing the connectors out of the way and out of
sight. To access the connectors, the user presses down on the
top of the enclosure, releasing a mechanical latch. A gas lift tips
the connectors into view.
All m o d e ls
•
•
•
•
UL/ CUL listing
CSA certification
Projector
Easy access to connectors
Durable mechanical movement and latching mechanism
Available in a variety of surface finishes
Extron HSA 200C
•
•
Includes a variety of RJ-45 connector bezel colors: black,
red, blue, orange, gray, white, ivory, yellow, and green
•
•
Compact size
Computer video and audio connections (HSA 200 models
only)
•
•
RJ-45 (CAT 6) network, data, or communications
connections (teminated in accordance with the
TIA/EIA 568 A standard)
Extron
HSA 200C
Hideaway Surface
Access Enclosure
Grounded AC receptacle(s)
HSA 200CE a n d HSA 200SE m o d e ls o n ly
HSA 200CE and 200SE models include an Extender line driver
board, which provides several features not available on the
standard models.
Mounted
Through a Table
or Podium
•
Signal boosting ability — The gain/ peaking adjustment
increases video signal voltages to compensate for signal
degradation caused by long cables. The Extender board
can send a high resolution signal up to 250 feet (76.2 m)
through Extron’s BNC-5 Mini HR cable.
Fig u re 1-4 — HSA 200C a p p lica t io n
•
•
Sync restoration — Each Extender board restores low
level sync voltages found on many laptops (as low as two
volts) to normal TTL levels.
Ab o u t t h e Ext e n d e r b o a rd lin e d rive r
Stereo audio — Unbalanced stereo audio inputs can be
output as balanced or unbalanced stereo audio.
The Extron Extender board in the HSA 200CE and 200SE is a
one-input VGA – UXGA/ VESA line driver with audio. It boosts
the video signal between a laptop or desktop computer and a
monitor or projector. It has a 300 MHz (-3 dB) video bandwidth.
The Extender accepts one computer-video input and one stereo
audio input, and features one buffered VGA-type RGB output
and one stereo audio output. With an optional Mac/ VGA
adapter, the Extender board can also buffer Macintosh signals.
HSA 200/222 Series • Introduction
1-4
HSA 200/222 Series • Introduction
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
In t ro d u ct io n
HSA 200/222 Series Surface Access Products
Chapter Tw o
2
In st a lla t io n
Installation Overview
Preparing the Routing Template
Preparing the Table and Mounting the Enclosure
Underside Features and Cabling Connections
Front Panel Connectors
Pre-installation Testing and Troubleshooting
(HSA 200CE and HSA 200SE Models Only)
HSA 200/222 Series • Introduction
1-6
Download from Www.Somanuals.com. All Manuals Search And Download.
In st a lla t io n
In st a lla t io n Ove rvie w
Pre p a rin g t h e Ro u t in g Te m p la t e
Extron provides a metal template for each HSA model at no
charge. Appendix A lists the HSA 200 and HSA 222 template
part numbers. Extron recommends using this template as a
guide to cut the hole in the table where the HSA will be
installed.
this chapter.
1
Conversion Kit manual, for either the HSA 200 models or
the HSA 222 models.
2
The metal routing template is reusable. Do not discard
this template when the installation is complete. Save it
for installing future HSA enclosures of the same size.
1.
Cut 1/ 2" x 4" strips of soft, finished lumber long enough to
span the distance between the desired installation location
on the mounting surface and the edges of the mounting
surface (figure 2-1).
If desired, install the optional flexible conduit kit to
replace the removable AC power cord. Refer to the
Flexible Conduit Kit manual.
3
4
Width of Mounting Surf
ace
Cut a hole in the surface where the enclosure will be
installed and install the enclosure. The screw clamps
secure the enclosure to the tabletop. See “Preparing the
Table and Mounting the Enclosure” in this chapter.
Mounting
Surface
Edge
Minimum
4 Screws
Run all cables necessary to support the AC power,
RJ-45, and (for HSA 200 model only) video and audio
connectors. Leave enough slack in the cables to connect
them to the underside of the enclosure.
5
6
Wood
Strips
Turn off all of the equipment to be connected. Ensure that
the equipment connected to the RJ-45, video, and audio
connectors are all turned off and disconnected from the
power source.
Wood Strip
Height
4" / 10.2 cm
Connect the power, video, audio, and RJ-45 cables to the
underside of the enclosure. See “Underside Features and
Cabling Connections” in this chapter.
7
8
Routing Template
Mounting
Surface
Edge
On HSA 200SE and HSA 200CE models, set the gain
Wood Thickness
0.5" / 1.3 cm
switch.
Connect and turn on the input and output devices.
9
Fig u re 2-1 — Pre p a re d m o u n t in g t e m p la t e a sse m b ly
For HSA 200SE and HSA 200CE model installations, the
picture should now appear and sound should be audible.
If not, ensure that all devices are plugged in and receiving
power. Check the cabling and gain setting, and make
adjustments as needed.
10
These strips raise the routing template above the mounting
surface to provide room for the router’s collar, protect the
mounting surface, and extend the reach of the routing
template so that it can be clamped to the edge of the surface.
Peel the protective coating from the top surface.
11
2.
Using four or more short wood screws, secure the
mounting template to the lumber strips.
Do not allow the wood screws to protrude through
the bottom of the wooden strips. Protruding screws
will mar the table when the template is used.
CAUTION
HSA 200/222 Series • Installation
2-2
HSA 200/222 Series • Installation
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
In st a lla t io n , co n t ’d
Preparing the Ta b le and Mounting the Enclosure
The preferred and recommended method for preparing the
table is to use the appropriate Extron routing template and a
router. The templates are available at no cost; see the part
numbers for the templates in appendix A, “Reference
Information”.
For an HSA 200C, HSA 200CE, or HSA 222C unit (US version
only), another preferred method is to use a 6" hole saw.
Alternatively, for any model, you can use a paper cut-out
template (see a ppendix A, “Reference Information”) and a
sabre saw or keyhole saw, but this method is not recommended.
The opening in the table for the HSA enclosure
should be cut only by licensed and bonded
craftspeople. Exercise care to prevent scarring or
damaging the furniture.
CAUTION
The routing templates for the various HSA models
are not interchangeable. If you use the wrong
template, you will cut an improperly-sized hole. If
you use a larger template than required, the cut will
result in gaps in the table surface on either side of
the enclosure.
Fig u re 2-2 — Cu t t in g t h e o p e n in g w it h a ro u t e r
(e xa m p le )
4.
Using a router with a 5/ 8" (or 16 mm) outside diameter
guide bushing and a 1/ 2" (or 12 mm or 12.7 mm)
diameter straight router bit, carefully cut the opening in
the table surface (figure 2-2).
The surfaces of the HSA enclosure have screws and
other protruding hardware that could damage fine
furniture. Do not rest the enclosure on unprotected
furniture.
Wear safety glasses when operating the router.
Failure to comply can result in eye injury.
Pre p a rin g t h e t a b le w it h a ro u t e r
5.
Remove the clamps and the routing template.
1.
Locate the desired mounting location on the tabletop or
The routing template is reusable. Do not discard the
template when the installation is complete. Save it to
install other HSA products of the same size.
other installation surface. Mark the location.
2.
Place the mounting template assembly on the table,
centered on the mounting location. Angle the template for
the optimum positioning. If necessary, use a square to
ensure that the template is properly positioned. Extron is
not responsible for improperly-positioned HSA products.
Ensure that only the wooden strips contact the
furniture. Failure to do so may mar the furniture.
CAUTION
3.
Once the template assembly is positioned properly, secure
the assembly to the table with clamps (figure 2-2).
HSA 200/222 Series • Installation
2-4
HSA 200/222 Series • Installation
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
In st a lla t io n , co n t ’d
2.
Remove the plastic strips that protect the corners of the
enclosure. If a sticky residue remains, remove it with an
appropriate metal cleaning product.
Pre p a rin g t h e t a b le w it h a h o le sa w (HSA 200C,
HSA 200CE, o r HSA 222C—US ve rsio n o n ly)
1.
Locate the desired mounting location on the tabletop or
other installation surface. Mark the 6" circle, then find the
center and mark it as well.
Do not use isopropyl alcohol or other solvents to clean
the HSA. Strong solvents will ruin some finishes.
CAUTION
3.
4.
Carefully lower the HSA enclosure into the hole to test the
fit. If necessary, remove the enclosure and use a file or
rasp to enlarge or smooth the edges of the opening.
Wear safety glasses when operating the hole saw.
Failure to comply can result in eye injury.
2.
Using a 6" hole saw on a portable drill, cut the mounting
hole at the desired location (figure 2-3). Extron is not
responsible for improperly positioned HSA products.
From the underside of the table, reinstall the screw clamps
on the enclosure at a height at which the clamp will reach
the underside of the tabletop (figure 2-4).
Use a portable drill with sufficient power for the 6"
hole saw. Exercise caution when handling the drill
and hole saw. Care should be taken to protect the
surface of the tabletop, podium, or other mounting
surface from damage.
CAUTION
Figure 2-4 shows an HSA 200 installation. Except for
the video and audio connectors, the HSA 222 installation
is identical.
Extron
HSA 200
C
A
T
6
Hideaway Surface
Access Enclosure
Output BNC
Connectors
(HSA 200 models only)
Mounting
Surface
Fig u re 2-3 — Cu t t in g t h e o p e n in g w it h a h o le sa w
Screw Clamp
In st a llin g t h e HSA e n clo su re (a ll)
Power Cord
1. Remove the screw clamps (2) on the sides of the enclosure.
Display BNC
Connectors
(HSA 200 models only)
2 RJ-45 Connectors
Audio Cable
(HSA 200 models only)
The flanged edges of the top of the surface enclosure
are bevelled to an ultra-fine thickness of less than
0.04 (4/100)" (approximately 1 mm), and are
therefore very sharp. These edges are also soft and
may be easily nicked or bent. Exercise caution
when handling and mounting the enclosure.
Mishandling may result in injury to the installer or
damage the appearance of the enclosure.
CAUTION
Fig u re 2-4 — Mo u n t in g t h e HSA 200 o r HSA 222
e n clo su re
HSA 200/222 Series • Installation
2-6
HSA 200/222 Series • Installation
2-7
Download from Www.Somanuals.com. All Manuals Search And Download.
In st a lla t io n , co n t ’d
5.
Snugly tighten the Philips head screws on the screw
clamps to secure the enclosure to the surface.
All HSA 200 m o d e ls o n ly
AC power outlet — Use this AC connector to:
1
Overtightening the Philips head screws on the screw
clamps can bend the clamp’s horizontal flange.
CAUTION
•
•
•
Plug in an external power supply to power the Extender
board on the HSA 200CE or HSA 200SE.
6.
7.
Tighten the locking thumbscrews on the screw clamps to
lock the clamp in position.
Provide AC power (5 amps max.) for loop through to one
additional HSA 200 unit.
Peel any remaining protective coating from the enclosure.
Plug in a projector or other display device.
This outlet is a US-style power outlet on both the US/
domestic and international HSA 200 models. The power
output is the same voltage and frequency as the power
input.
Un d e rsid e Fe a t u re s a n d Ca b lin g Co n n e ct io n s
Figure 2-5 shows the under-table connectors and other features
that present on HSA 200CE models. Other HSA 200 and
HSA 222 models have a subset of the same or similar features.
RGBHV video output — Connect the BNC cable from the
projector, plasma screen, or other display device to these female
BNC connectors.
2
HSA 200C and HSA 200S (no Extender board) — The output
from these connectors is an unbuffered pass-through from the
front panel VGA input.
HSA 200CE and HSA 200SE (Extender board) — The output on
MEDIUM
NORMAL
unity gain
MAXIMUM
peaking
gain POWER
9-18 VDC
peaking
&
gain
&
AUDIO
R
R
L
L
these connectors is buffered by the Extender board.
4
1
HSA 200C a n d HSA 200S (n o Ext e n d e r b o a rd ) o n ly
*
On HSA 200 models with no Extender board, the audio
connection is part of the pigtail (figure 2-6).
Back View
8
*
2
11●
* HSA 200 Models Only
*
13●
●
HSA 200CE/HSA 200SE
9
Units Only
✝
✝
HSA 200S/HSA 200C
✝
10●
7
12●
3
(no Extender board) units only
Fig u re 2-6 — HSA 200S a n d HSA 200C a u d io co n n e ct o r
Audio output connection — This 3-pole direct insertion
terminal outputs unbalanced audio, passed through from the
front panel. Figure 2-7 shows how to wire the connector.
3
5
Unbalanced Output
Tip (L)
Sleeve/Ground
Tip (R)
Bottom View
Fig u re 2-7 — Un b u ffe re d , u n b a la n ce d a u d io
co n n e ct o r w irin g
6A 6B
Fig u re 2-5 — HSA 200CE u n d e r-t a b le fe a t u re s
HSA 200/222 Series • Installation
2-8
HSA 200/222 Series • Installation
2-9
Download from Www.Somanuals.com. All Manuals Search And Download.
In st a lla t io n , co n t ’d
All HSA 200 a n d HSA 222 m o d e ls
Latch locking screws — These screws secure the latching
mechanism to the enclosure. They must be loosened in order to
adjust the top surface (see “Adjusting the Top Panel” in
8
7
Screw clamp bracket/screw clamp — These two brackets/
4
clamps hold the enclosure firmly in place in the mounting hole.
chapter 3) with the top surface adjustment screw
.
AC power input connection — Connect this cord to the power
source.
5
Top surface adjustment screw — After loosening the latch
8
7
locking screws
, adjust the top surface of the tilt up panel with
this screw. Tighten the latch locking screws after adjustment.
For US-domestic versions, this power cord is
permanently connected to the HSA.
Connect the power cord to a 125VAC, 60 Hz,
5A power source.
Gas lift mounting plate — The lower end of the gas lift is
attached to this plate. The plate must be detached from the
enclosure in order to remove the gas lift.
9
For international versions, this power cord is a
removable IEC power cord. Connect the cord
to a 220-240V, 50/60 Hz, 5A power source.
HSA 200CE a n d HSA 200SE (Ext e n d e r b o a rd ) o n ly
Audio output connection — This 5-pole direct insertion
terminal outputs unbalanced or balanced audio. Figure 2-9
shows how to wire the connector.
10
You can replace this connector with an optional Extron HSA 200/
HSA 222 Flexible Conduit Adapter kit (part #70-229-01).
Unbalanced Output
Tip
See Caution
Sleeve (s)
Tip
Balanced Output
Tip
Ring
Sleeve (s)
RJ-45 connectors — Plug one end of a CAT 5 or CAT 6 twisted
pair (TP) cable into each of these RJ-45 female connectors.
Connect the other end to an appropriate telecommunications or
data network or to an Extron TP product.
6
Tip
Ring
See Caution
All RJ-45 connectors are teminated in accordance with
the TIA/EIA 568 A standard.
Fig u re 2-9 — Ext e n d e r b o a rd a u d io
co n n e ct o r w irin g
MEDIUM
Peaking and Gain
An RJ-11 plug can be connected to the RJ-45 jack.
Connect the sleeve to
ground (Gnd).
Connecting the sleeve to a
negative (-) terminal will
CAUTION
NORMAL
Unity Gain
MAXIMUM
Peaking and
Gain
When cabling the front panel and the underside of the enclosure
(figure 2-8), ensure that the bottom RJ-45 connections match up
with the front panel RJ-45 connector locations. For example,
match the front panel RJ-45 (CAT 6) network, data, or
damage the audio output circuits.
communications connection
with the underside RJ-45
and so forth.
5A
Gain switch — To compensate for cable resistance and
capacitance, use a Tweeker to slide this switch to select the level
of video gain that yields the sharpest, smear-free picture.
11
connector 6A , match
with
6B
5B
Normal — unity gain (no signal boost)
Medium — mid-level peaking and gain
5A
5B Front View
Maximum — maximum amount of peaking and gain. Select
this setting for use with longer cables.
Adjust the gain before installing the HSA unit, as the
gain switch may be inaccessible after installation.
6A 6B
Power supply connection — Plug the external power supply
(included) output wires into this 2-pole direct insertion
terminal. See “Power connector wiring” to wire the connector.
12
Bottom View
Power LED — Indicates when the Extender board is receiving
13
power.
Fig u re 2-8 — Co n fig u ra t io n o f RJ-45 co n n e ct o rs
HSA 200/222 Series • Installation
2-10
HSA 200/222 Series • Installation
2-11
Download from Www.Somanuals.com. All Manuals Search And Download.
In st a lla t io n , co n t ’d
Do not tin the stripped power supply leads. Tinned
wires are not as secure in the captive screw terminals
and could pull out.
Po w e r co n n e ct o r w irin g
1.
See figure 2-10. Plug the input connector of the included
100-240 VAC, 50/ 60Hz, 12 VDC power supply into the AC
1
power outlet on the underside of the enclosure ( on
figure 2-5).
The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before continuing.
To verify the polarity before connection, plug in the
power supply with no load and check the output with a
voltmeter.
Fro n t Pa n e l Co n n e ct o rs
MEDIUM
peaking gain
NORMAL
unity gain
MAXIMUM
peaking
gain POWER
Figure 2-12 shows the front panel of the HSA 200 models.
Figure 2-13 shows the front panel of the HSA 222.
&
&
9-18 VDC
AUDIO
R
R
L
L
2
3
HSA 200
●
4
Power Supply
Back View
Fig u re 2-10 — Po w e rin g t h e Ext e n d e r b o a rd
This outlet is a US-style power outlet on both the US/
domestic and international HSA 200 models. The power
output is the same voltage and frequency as the power
input and is an acceptable power input to the power
supply included with the HSA.
●
HSA 200CE and
HSA 200SE Models Only
1
5A
5B
Fig u re 2-12 — HSA 200 fro n t p a n e l co n n e ct o rs
2.
Insert the external power supply (included) output wires
into the 2-pole direct insertion captive screw terminal on
the Extender board (figure 2-11) and secure the wires.
HSA 222
125V
50/60 Hz 5A
125V
50/60 Hz 5A
CAUTION
When connecting the power supply wires, voltage
polarity is extremely important. Applying power
with incorrect voltage polarity could damage the
power supply and the Extender board in the HSA.
Black Wire
White Wire
12V
+
-
1
5A
5B
1
Fig u re 2-13 — HSA 222 fro n t p a n e l co n n e ct o rs
Captive Screw
Terminal
AC power outlet(s) — Plug a standard power cord into this
connector to provide AC power (5 amps max.) for a laptop or
other device. The power output will be the same voltage and
frequency as power input. The power outlet(s) will be
appropriate to the model.
1
Fig u re 2-11 — Po w e r co n n e ct o r w irin g
HSA 200/222 Series • Installation
2-12
HSA 200/222 Series • Installation
2-13
Download from Www.Somanuals.com. All Manuals Search And Download.
In st a lla t io n , co n t ’d
The Universal AC outlet is fully compatible with
Europlug, British, Indian, Danish, and Italian plug
types. See the universal AC outlet guide on the Extron
all plug types.
5A
5B Front View
Computer video input (HSA 200 models only) — Plug the
VGA-UXGA output from a computer into this 15-pin HD female
connector.
2
6A 6B
Audio input connector (HSA 200 models only) — Plug a
3.5 mm stereo plug into this jack for unbalanced audio input.
Figure 2-14 shows how to wire the male plug.
3
Tip (+)
Bottom View
Ring (
-)
Fig u re 2-15 — Co n fig u ra t io n o f RJ-45 co n n e ct o rs
Sleeve (
)
Fig u re 2-14 — Au d io in p u t co n n e ct o r p lu g
Icon Label
Power/Signal LED (HSA 200SE and HSA 200CE only) — This
LED lights green when power and an input signal are present.
The LED lights amber when power is present but no input
signal is present.
4
5
RJ-45 connectors — Plug a CAT 5 or CAT 6 twisted pair (TP)
cable into each of these RJ-45 female connectors for network,
data, or communication connections.
Fig u re 2-16 — Ch a n g in g t h e co n n e ct o r ico n
When cabling the front panel and the underside of the enclosure
(figure 2-15), ensure that the bottom RJ-45 connections match up
with the front panel RJ-45 connector locations. For example,
match the front panel RJ-45 (CAT 6) network, data, or
communications connection
with the underside RJ-45
5A
connector
and match
with
5B
.
6B
6A
If necessary, on the front panel, have a qualified service person
replace the connector icon by prying the old icon off of the
connector plug-in with a Tweeker (figure 2-16) and snapping a
new icon in place.
HSA 200/222 Series • Installation
2-14
HSA 200/222 Series • Installation
2-15
Download from Www.Somanuals.com. All Manuals Search And Download.
In st a lla t io n , co n t ’d
Pre -in st a lla t io n Te st in g a n d Tro u b le sh o o t in g
(HSA 200CE a n d HSA 200SE Mo d e ls On ly)
HSA 200/222 Series Surface Access Products
Before installing an HSA 200 with an Extender line driver into
furniture, test the system to make sure that the connections and
settings are correct.
1.
Apply power to the line driver. The power/ signal LED on
the line driver will light to indicate that the line driver is
receiving power.
If the LED does not light, check the wiring at both the line
driver and the power supply, and ensure that the power
supply is connected to a power source.
If t h e im a g e d o e s n o t a p p e a r o r t h e re is n o so u n d
1.
2.
Make sure that all the devices are powered on.
Ensure that the connectors are wired correctly at both ends
of the cables. Audio cables must be wired for an
unbalanced stereo input signal and for the appropriate
(unbalanced or balanced) output signal.
Chapter Three
3. If the input is from a laptop computer and no picture
appears, use a laptop breakout cable for the input
connection. Check the computer’s user’s guide or contact
Extron to determine if special commands are required to
output video to the external video port. Also, many
laptops’ screens shut off after the external video port is
activated.
3
4.
Call the Extron S3 Sales and Technical Support Hotline if
the image still does not appear or there is no sound.
Ma in t e n a n ce a n d Mo d ifica t io n s
If t h e im a g e is n o t d isp la ye d co rre ct ly
Removing and Replacing the Enclosure
Replacing the Bezels
1.
If the picture is too bright or too dark, or if the edges of the
image seem to exceed their boundaries, or if thin lines and
sharp edges look thick and fuzzy, change the gain setting.
2.
If the picture appears and is stable, but it has ghosting or
blooming, verify that the video input is properly
Replacing the Gas Lift
terminated. If the problem is not resolved by changing the
termination, try using a different input cable. Poor quality
or damaged cable can cause ghosting and blooming.
Adjusting the Top Panel
3.
If the picture still is not displayed correctly, call the Extron
S3 Sales and Technical Support Hotline.
HSA 200/222 Series • Installation
2-16
Download from Www.Somanuals.com. All Manuals Search And Download.
Ma in t e n a n ce a n d Mo d ifica t io n s
The most probable corrective maintenance procedures for your
The surfaces of the HSA enclosure have screws and other
protrusions that could damage fine furniture. Do not
rest the enclosure on unprotected furniture.
HSA 200 or HSA 222 are leveling the top surface and replacing
the gas lifts. Most of the maintenance procedures require
removing the surface mount enclosure from the table.
5.
6.
Perform the desired maintenance procedure.
If the surface is not level, adjust the top surface. See
“Adjusting the Top Panel” in this chapter.
Re m o vin g a n d Re p la cin g t h e En clo su re
•
•
•
The procedure for replacing the bezel in an HSA 222 only
requires removing the HSA from the table.
7.
8.
Carefully lower the HSA enclosure into the table opening.
From the underside of the table, reinstall the screw clamps
on the enclosure at a height at which the clamp will reach
the underside of the tabletop.
The procedure for replacing the gas lift requires removing
the HSA 200 or HSA 222.
The procedure for levelling the top surface may require
9.
Snugly tighten the Philips head screws on the screw
clamps to secure the enclosure to the surface.
removing the HSA.
Remove and replace the surface mount enclosure for
maintenance as follows:
Overtightening the Philips head screws on the screw
clamps can bend the clamp’s horizontal flange.
CAUTION
Ensure that AC power is disconnected before
servicing the HSA unit.
10. Tighten the locking thumbscrews on the screw clamps to
lock the clamp in position.
1.
Disconnect:
11. Reconnect all of the connectors removed in step 1.
•
•
The IEC power cord
The RJ-45 connectors from the underside of the surface
mount enclosure
Re p la cin g t h e Be ze ls
The HSA ships with RJ-45/ RJ-11 connector bezel plug-ins in a
variety of colors and a black, blank bezel.
•
(HSA 200 models only) Any device plugged into the AC
power outlet
To change to a different color connector bezel or if a connector is
not needed, replace the connector bezel
plug-in on the front panel with a bezel of
a different color or a blank plug-in.
•
•
•
(HSA 200 models only) The BNC (video) connectors
(HSA 200 models only) The audio connector
(HSA 200CE and HSA 200SE only) The power supply
connector
If no connector is desired, snap the
interior RJ-45 connector onto the rear of
the blank bezel plug-in to hold it
conveniently out of the way. Retain the
removed connector bezel plug-in for later use.
2.
Loosen the locking
thumbscrews on the screw
clamps to unlock the clamp.
Screw
Clamp
Thumbscrew
3.
Loosen the screw clamps.
Replace a bezel as follows:
4.
Remove the screw clamps on
both sides of the enclosure.
Lift the enclosure from the table.
1.
(HSA 222 models only) Remove the surface mount
enclosure from the table. See “Removing and Replacing
the Enclosure”, steps 1 through 4.
The flanged edges of the top of the surface enclosure
are bevelled to an ultra-fine thickness of less than
0.04 (4/100)” (approximately 1 mm), and are
therefore very sharp. These edges are also soft and
may be easily nicked or bent. Exercise caution
when handling and mounting the enclosure.
Mishandling may result in injury to the installer or
damage the appearance of the enclosure.
CAUTION
HSA 200/222 Series • Maintenance and Modifications
3-2
HSA 200/222 Series • Maintenance and Modifications 3-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d
2.
(HSA 222 models only) Remove the four Philips head
screws from the front access panel (figure 3-1). Retain the
screws. Lift the panel away from the enclosure.
3.
(HSA 222 models only) Disconnect both RJ-45 connectors
from the underside of the enclosure by simultaneously
performing steps 3a and 3b:
a.
With a Tweeker in one hand, reach through the small
access hole in the front of the enclosure (figure 3-2)
and gently pry outward on the front of the RJ-45
connector detent on the bezel plug-in,
— while you —
b.
Reach your other hand through the front panel access
hole and tilt the connector back.
This disconnects the connector from the interior of the
lower enclosure without damaging the bezel plug-in.
Remove
front access
panel.
Fig u re 3-1 — Re m o vin g t h e fro n t a cce ss p a n e l
(HSA 222 m o d e ls)
Fig u re 3-2 — Re le a sin g t h e b e ze l p lu g -in d e t e n t
(HSA 222 m o d e ls)
HSA 200/222 Series • Maintenance and Modifications
3-4
HSA 200/222 Series • Maintenance and Modifications 3-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d
4.
Remove the four 1/ 16" hex head screws on the right and
left sides of the front panel (figure 3-3). Retain the screws.
Lift the panel away from the enclosure.
8.
9.
Snap the internal RJ-45 connector onto the back of the front
panel enclosure bezel plug-in.
(HSA 222 models only) Reach your hand through the
front panel access hole and snap the lower internal RJ-45
connectors onto the back of the lower enclosure bezel
plug-ins.
Figure 3-3 shows an HSA 200 model. Removing the
front panel from an HSA 222 is an identical procedure.
Remove 2 hex head
screws on each side.
10. Replace the front panel in the surface mount enclosure and
secure it in place with the hex head screws removed in
step 4.
11. (HSA 222 models only) Replace the front access panel in
the surface mount enclosure and secure it in place with the
Philips head screws removed in step 2.
HSA 200
A
12. (HSA 222 models only) Reinstall the surface mount
enclosure. See Removing and Replacing the Enclosure, steps 6
through 11.
UDIO
Lift panel out
of enclosure.
Fig u re 3-3 — Re m o vin g t h e fro n t p a n e l
5.
With a Tweeker, push down on and
gently twist on the front of each RJ-45
connector detent to disconnect the
connector from the rear of the front panel
plug-in.
6.
7.
Pinch the top and bottom bezel detents
together and push the bezel through the
front panel.
Snap a replacement bezel in place. If necessary, replace the
connector icon by prying the old icon off of the connector
plug-in with a Tweeker (figure 3-4) and snapping a new
icon in place.
Icon Label
Fig u re 3-4 — Ch a n g in g t h e co n n e ct o r ico n
HSA 200/222 Series • Maintenance and Modifications
3-6
HSA 200/222 Series • Maintenance and Modifications 3-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d
Re p la cin g t h e Ga s Lift
5.
Turn the surface mount enclosure onto its back side and
open the top panel.
The gas lift that raises the HSA surface is rated for 100,000
opening and closing cycles. Replace the gas lift as follows:
With the gas lift removed, the top panel must be
manually lifted.
Ensure that AC power is disconnected before
servicing the HSA unit.
6.
(HSA 200 models only) Remove the four 1/ 16" hex head
screws on the right and left sides of the front panel
(figure 3-6). Retain the screws. Lift the panel away from
the enclosure.
When the HSA 200 is upside-down, the latch may
be ineffective. If the latch releases in this position,
the enclosure will tip and could damage the flanged
edges. Keep a free hand on the enclosure to keep it
from tipping.
CAUTION
Figure 3-6 shows an HSA 200 model. Removing the
front panel from an HSA 222 is an identical procedure.
1.
2.
Remove the surface mount enclosure from the table. See
Removing and Replacing the Enclosure, steps 1 through 4.
Place the enclosure upside-down on a horizontal surface.
To protect the finish, place the enclosure on a soft cloth.
Remove 2 hex head
screws on each side.
Loosen the three Philips head screws that secure the gas
lift mounting plate in place (figure 3-5).
HSA 200
A
UDIO
Lift panel out
of enclosure.
Unscrew mounting plate
from gas lift.
Fig u re 3-6 — Fro n t p a n e l re m o va l (HSA 200 m o d e ls)
Loosen (3)
screws.
Fig u re 3-5 — Re m o vin g t h e g a s lift m o u n t in g p la t e
Figure 3-5 shows an HSA 200 model. Removing the gas
lift mounting plate from an HSA 222 is an identical
procedure.
3.
4.
Slide the gas lift mounting plate toward the center of the
enclosure, releasing the mounting plate (figure 3-5).
Turn the gas lift mounting plate counterclockwise until the
plate comes free from the shaft of the gas lift (figure 3-5).
HSA 200/222 Series • Maintenance and Modifications
3-8
HSA 200/222 Series • Maintenance and Modifications 3-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d
7.
(HSA 222 models only) Remove the four Philips head
screws from the front access panel (figure 3-7). Retain the
screws. Lift the panel away from the enclosure.
8.
Remove the pivot nut from the upper pivot bolt, then
remove the bolt, releasing the upper end of the gas lift
from the top panel. Pull the gas lift from the bottom of the
enclosure.
HSA 200 models — Reach through the front panel
opening (figure 3-8).
HSA 222 models — Reach through the front access panel
(figure 3-9 on page 3-12).
Top Clevis
Pivot Bolt
Pivot Nut
Remove
front access
panel.
Piston End
Fig u re 3-7 — Fro n t a cce ss p a n e l re m o va l (HSA 222
m o d e ls)
Gas Lift
Fig u re 3-8 — Re p la cin g t h e g a s lift , HSA 200 m o d e l
HSA 200/222 Series • Maintenance and Modifications
3-10
HSA 200/222 Series • Maintenance and Modifications 3-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d
Ad ju st in g t h e To p Pa n e l
Level the top panel of the HSA 200 or HSA 222 as follows:
1.
If necessary to view the top and the underside of the
enclosure simultaneously, remove the surface mount
enclosure from the table. See Removing and Replacing the
Enclosure, steps 1 through 4.
Remove
pivot nut.
2.
3.
Close and latch the top panel.
Slightly loosen the two latch locking screws (figure 3-10)
on the underside of the surface mount enclosure. These
screws lock the latch in place once it is adjusted.
Adjustment
Screw
Remove
gas lift.
Fig u re 3-9 — Re p la cin g t h e g a s lift , HSA 222 m o d e l
9.
Insert the piston end of the replacement gas lift through
the hole in the bottom of the enclosure adjacent to the latch
and secure the lift in the clevis on the top panel with the
nut and bolt that were removed in step 8.
Latch Locking
Screws
10. (HSA 200 models only) Replace the front panel in the
surface mount enclosure and secure it in place with the
hex head screws removed in step 6.
Fig u re 3-10 — Ad ju st in g t h e t o p p a n e l
11. (HSA 222 models only) Replace the front access panel in
the surface mount enclosure and secure it in place with the
Philips head screws removed in step 7.
4.
Gently turn the adjustment screw on the rear of the surface
mount enclosure to raise or lower the top panel to level it
with the flange. Turning the screw counterclockwise raises
the panel and clockwise lowers the panel.
12. Thread the pivot nut on the gas lift mounting plate onto
the shaft of the gas lift and tighten it several turns.
5.
6.
Once the top panel is level, tighten the two latch locking
screws on the underside of the surface mount enclosure.
13. Firmly push the gas lift mounting plate into position on
the underside of the surface mount enclosure, engaging
the three mounting screws that were loosened in step 2.
Holding the plate in position with one hand, secure it to
the enclosure with the three screws.
If the surface mount enclosure was removed, reinstall it. See
Removing and Replacing the Enclosure, steps 7 through 11.
14. Reinstall the surface mount enclosure. See “Removing and
Replacing the Enclosure”, steps 6 through 11.
HSA 200/222 Series • Maintenance and Modifications
3-12
HSA 200/222 Series • Maintenance and Modifications 3-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Ma in t e n a n ce a n d Mo d ifica t io n s, co n t ’d
HSA 200/222 Series Surface Access Products
Appendix A
A
Re fe re n ce In fo rm a t io n
Specifications
HSA Part Numbers
Included Parts
Routing Templates
Replacement Parts
Accessories
Top Plate Dimensions
HSA 200/222 Series • Maintenance and Modifications
3-14
Download from Www.Somanuals.com. All Manuals Search And Download.
Re fe re n ce In fo rm a t io n
Au d io — HSA 200SE, HSA 200CE
Sp e cifica t io n s
Gain ................................. Unbalanced output: 0 dB; balanced output: +6 dB
Vid e o — HSA 200SE, HSA 200CE
Frequency response ...... 20 Hz to 20 kHz, ±0.5 dB
Gain ................................. Selectable: unity (0.7 V), (0.75 V) 50%, (0.8 V)
100%
THD + Noise .................. 0.025% @ 1 kHz, 0.020% @ 20 kHz at nominal
level
Bandwidth ..................... 300 MHz (-3 dB)
S/ N ................................. >90 dB at rated maximum output (21 dB,
balanced)
ID bits are terminated on pins 4 and 11.
Stereo channel separation >75 dB @ 20 Hz to 20 kHz
Vid e o in p u t — HSA 200S, HSA 200C
Au d io in p u t — HSA 200S, HSA 200C
Number/ signal type .... 1 stereo, unbalanced
Connectors ..................... (1) 3.5 mm stereo female jack
Number/ signal type .... 1 VGA–UXGA RGBHV, RGBS, RGsB, RsGsBs
Connectors ..................... (1) 15-pin HD female
Vid e o in p u t — HSA 200SE, HSA 200CE
Number/ signal type .... 1 VGA–UXGA RGBHV, RGBS, RGsB, RsGsBs
Connectors ..................... (1) 15-pin HD female
Au d io in p u t — HSA 200SE, HSA 200CE
Number/ signal type .... 1 stereo, unbalanced
Connectors ..................... (1) 3.5 mm stereo female jack
Impedance ...................... >10k ohms unbalanced, DC coupled
Nominal level ................ -10 dBV (316 mVrms)
Nominal level ................ 0.7 Vp-p for RGB
Min./ max. levels ........... Analog: 0.3 V to 1.5 Vp-p with no offset at unity
gain
Maximum level ............. +6 dBu, (balanced or unbalanced) at 1%THD+N
Impedance ...................... 75 ohms
Au d io o u t p u t — HSA 200S, HSA 200C
Horizontal frequency ... 15 kHz to 135 kHz
Vertical frequency ......... 30 Hz to 170 Hz
Number/ signal type .... 1 pass-through stereo, unbalanced
Connectors ..................... (1) 3.5 mm, direct insertion captive screw
connector, 3 pole
Vid e o o u t p u t — HSA 200S, HSA 200C
Number/ signal type .... 1 pass-through VGA–UXGA RGBHV, RGBS,
RGsB, RsGsBs
Au d io o u t p u t — HSA 200SE, HSA 200CE
Number/ signal type .... 1 stereo, balanced/ unbalanced
Connectors ..................... 5 BNC female on pigtails
Connectors ..................... (1) 3.5 mm direct insertion captive screw
connector, 5 pole
Vid e o o u t p u t — HSA 200SE, HSA 200CE
Number/ signal type .... 1 VGA–UXGA RGBHV, RGBS, RGsB, RsGsBs
Connectors ..................... 5 BNC female on pigtails
Nominal level ................ 0.7 Vp-p for RGB
Impedance ...................... 50 ohms unbalanced, 100 ohms balanced
Nominal level ................ Unbalanced output: -10 dBV (316 mVrms)
Balanced output: -2 dBu (632 mVrms)
Min./ max. levels ........... Analog: 0.3 V to 1.5 Vp-p
Impedance ...................... 75 ohms
Max. level (Hi-Z) ........... >+14 dBu, balanced at 1% THD+N
Max. level (600 ohm) .... >+5.5 dBm, balanced at 1% THD+N
DC offset ........................ ±5 mV with input at 0 offset
0 dBu = 0.775 Vrms. 0 dBV = 1 Vrms. 0 dBV 2 dBu.
Syn c — HSA 200SE, HSA 200CE
Input type ....................... RGBHV, RGBS, RGsB, RsGsBs
Output type ................... RGBHV, RGBS, RGsB, RsGsBs
Input level ...................... 2.0 V to 5.0 Vp-p
Output level ................... TTL: 5.0 Vp-p, unterminated
Input impedance ........... 510 ohms
Output impedance ........ 75 ohms
Max. propagation delay 18.8 ns
Max. rise/ fall time ........ 4 ns
Polarity ........................... Positive or negative (follows input)
HSA 200/222 Series • Reference Information
A-2
HSA 200/222 Series • Reference Information
A-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Re fe re n ce In fo rm a t io n , co n t ’d
HSA 200C, HSA 200CE — USA models
Top plate (outer rim)................... 6.500" diameter circle
(16.51 cm diameter) circle
Ge n e ra l
The Universal AC outlet is fully compatible with Europlug,
Surface cutout (inside rim)......... 6.000 ±0.0325" diameter circle
(15.24 ±0.083 cm diameter) circle
Top plate (inside tilt plate) ......... 4.344" W x 3.000" D
(11.03 cm W x 7.62 cm D)
British, Indian, Danish, and Italian plug types. See the
Universal AC outlet guide on the Extron Web site,
www.extron.com, for compatibility details on all plug types
Power (HSA 200SE/ CE) Supplied by an external power supply
HSA 222C — USA model
Top plate (outer rim)................... 6.500" diameter circle
(16.51 cm diameter) circle
Surface cutout (inside rim)......... 6.000 ±0.0325" diameter circle
(15.24 ±0.083 cm diameter) circle
Top plate (inside tilt plate) ......... 4.660" W x 2.875" D
(11.84 cm W x 7.30 cm D)
External power supply (HSA 200SE/ CE)
100 VAC to 240 VAC, 50/ 60 Hz, external,
autoswitchable; to 12 VDC, 0.42 A, regulated
Power input requirements (HSA 200SE/ CE)
12 VDC, 0.2 A
Temperature/ humidity — HSA 200SE/ CE
Storage: -40 to +158°F (-40 to +70°C) / 10% to
90%, noncondensing
HSA 200S, HSA 200SE, HSA 200C, HSA 200CE — USA models
Box (under surface) ..................... 4.0" H x 4.6" W (front of unit) x 4.4" D
(10.2 cm H x 11.7 cm W x 11.2 cm D)
without clamps
Operating: +32 to +122°F (0 to +50°C) / 10% to
90%, noncondensing
Rack mount .................... No, but furniture mountable
Enclosure type ............... Metal
4.0" H x 8.0" W (front of unit) x 4.4" D
(10.2 cm H x 20.3 cm W x 11.2 cm D)
with clamps
Enclosure dimensions
HSA 222S, HSA 222C — USA models
Use the appropriate metal Extron routing template or refer to
the surface cutout dimensions here before cutting a hole in the
furniture or other surface. Pay special attention to the direction
the unit will face; the unit’s connector access side is underlined.
Extron is not responsible for miscut mounting holes.
CAUTION
Box (under surface) ..................... 5.6" H x 5.3" W (front of unit) x 3.6" D
(14.2 cm H x 13.5 cm W x 9.1 cm D)
without clamps
5.6" H x 8.6" W (front of unit) x 3.6" D
(14.2 cm H x 21.8 cm W x 9.1 cm D)
with clamps
HSA 200S, HSA 200SE — USA models
Top plate (outer rim)................... 6.470" W x 5.125" D
(16.43 cm W x 13.02 cm D)
Surface cutout (inside rim)......... 5.970 ±0.0325" W x 4.625 ±0.0325" D
(15.16±0.083cm W x 11.75±0.083cm D)
HSA 200S/HSA 200SE — international square models
Top plate (outer rim)................... 8.183" W x 6.375" D
(20.79 cm W x 16.19 cm D)
Surface cutout (inside rim)
7.683 ±0.0325" W x 5.875 ±0.0325" D
(19.51±0.083cm W x 14.92±0.083cm D)
Top plate (inside tilt plate) ......... 4.344" W x 3.000" D
(11.03 cm W x 7.62 cm D)
Top plate (inside tilt plate)
5.90" W x 4.10" D
HSA 222S — USA model
Top plate (outer rim)................... 6.470" W x 5.125" D
(16.43 cm W x 13.02 cm D)
(14.99 cm W x 10.41 cm D)
HSA 222S — international square models
Top plate (outer rim)................... 8.183" W x 6.375" D
(20.78 cm W x 16.19 cm D)
Surface cutout (inside rim)......... 7.683 ±0.0325" W x 5.875 ±0.0325" D
(19.51±0.083cm W x 14.92±0.083cm D)
Surface cutout (inside rim)......... 5.970 ±0.0325" W x 4.625 ±0.0325" D
(15.16±0.083cm W x 11.75±0.083cm D)
Top plate (inside tilt plate) ......... 4.660" W x 2.875" D
(11.84 cm W x 7.30 cm D)
Top plate (inside tilt plate) ......... 6.183" W x 3.75" D
(15.70 cm W x 9.53 cm D)
HSA 200/222 Series • Reference Information
A-4
HSA 200/222 Series • Reference Information
A-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Re fe re n ce In fo rm a t io n , co n t ’d
HSA 200C/HSA 200CE — international circular models
Top plate (outer rim)................... 8.5" diameter circle
(21.6 cm diameter) circle
HSA Pa rt Nu m b e rs
HSA 200S
Pa rt n u m b e r
HSA 200S US/ domestic (black anodized finish)
60-510-01
Surface cutout (inside rim)......... 8.0" diameter (20.3 cm diameter) circle
HSA 200S International
60-705-nn
Top plate (inside tilt plate) ......... 5.9" W x 4.1" D
(15.1 cm W x 10.4 cm D)
HSA 200 — international, all models
HSA 200SE
Pa rt n u m b e r
60-511-01
Box (under surface) ..................... 4.0" H x 6.3" W (front of unit) x 5.0" D
(10.2 cm H x 15.9 cm W x 12.7 cm D)
without clamps
HSA 200SE US (black anodized finish)
HSA 200SE International
60-706-nn
4.0" H x 10.0" W (front of unit) x 5.0" D
(10.2 cm H x 25.3 cm W x 12.7 cm D)
with clamps
HSA 200C
Pa rt n u m b e r
HSA 222 — international, all models
HSA 200C US/ domestic (black anodized finish)
60-512-01
Box (under surface) ..................... 4.5" H x 6.6" W (front of unit) x 4.9" D
(11.4 cm H x 16.8 cm W x 12.4 cm D)
without clamps
HSA 200C International
60-703-nn
4.5" H x 10.3" W (front of unit) x 4.9" D
(11.4 cm H x 26.2 cm W x 12.4 cm D)
with clamps
HSA 200CE
Pa rt n u m b e r
60-513-01
HSA 200CE US/ domestic (black anodized finish)
HSA 200CE International
60-704-nn
Product weight
HSA 200S, HSA 200C ................. 4.0 lbs (1.8 kg)
HSA 222S, HSA 222C ................. 3.5 lbs (1.6 kg)
HSA 200SE, HSA 200CE .............. 5.0 lbs (2.3 kg)
HSA 222
Pa rt n u m b e r
60-630-01
HSA 222S US/ domestic (black anodized finish)
HSA 222C US/ domestic (black anodized finish)
HSA 222S International
Shipping weight
60-631-01
HSA 200S, HSA 200C, HSA 222S, HSA 222C
7 lbs (4 kg)
60-701-nn
HSA 200SE, HSA 200CE ............. 8 lbs (4 kg)
For the international versions, the nn in the part number
identifies the AC power connector and finish (black
anodized, brushed aluminum, polished aluminum, and
brushed brass). Specify the desired power connector and
finish when ordering.
Vibration ............................................. ISTA 1A in carton
(International Safe Transit Association)
Listings, certifications ....................... UL, CUL
Compliances
HSA 200SE, HSA 200CE ............. CE, FCC Class A, VCCI, AS/ NZS, ICES
MTBF ................................................... 30,000 hours
Warranty ............................................. 3 years parts and labor
The USA versions of the HSA 200 and HSA 222 are also
available in brushed aluminum, polished aluminum, and
brushed brass finishes. Visit the Extron Web site,
All nominal levels are at ±10%
Specifications are subject to change without notice.
HSA 200/222 Series • Reference Information
A-6
HSA 200/222 Series • Reference Information
A-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Re fe re n ce In fo rm a t io n , co n t ’d
In clu d e d Pa rt s
Pa rt
HSA 200S/HSA 200SE/HSA 222S US Models
6.470" (16.43 cm)
Pa rt n u m b e r
HSA 200 and HSA 222 User’s Manual
+
+
5.970 0.0325" (15.16 0.083 cm)
RJ-45 connector bezel plug-in inserts (assorted colors) 70-201-01
Power supply, 100-240VAC, 50/ 60Hz, 12VDC
(HSA 200SE and HSA 200 CE only)
28-104-01
SURFACE CUT-OUT
AREA = 5.970 0.0325"
+
Tweeker
+
+
(15.16 0.083 cm) x 4.625 0.0325"
5.125"
(13.02 cm)
+
(11.75 0.083 cm)
+
+
4.625 0.0325"
Ro u t in g Te m p la t e s
(11.75 0.083 cm)
Te m p la t e
Pa rt n u m b e r
70-237-01
HSA 200/ HSA 222 US routing template
HSA 200/ HSA 222 International routing template
70-237-02
0.5"
(1.3 cm)
Re p la ce m e n t Pa rt s
Cut surface material
out along this line.
Tilting Plate
Cut-Out Radius:
0.25" (0.6 cm)
Top Panel
Pa rt
Pa rt n u m b e r
70-281-01
HSA 200 gas lift
HSA 222 gas lift
User Access (Connectors and AAP Openings)
70-281-02
TEMPLATE IS NOT FULL SIZE.
Acce sso rie s
Pa rt
Pa rt n u m b e r
70-231-01
HSA 200S/HSA 200SE International Models
8.183" (20.78 cm)
HSA 200 RJ-45 to RJ-11 Conversion Kit
HSA 222 RJ-45 to RJ-11 Conversion Kit
HSA 200/ HSA 222 Flexible Conduit Adapter Kit
70-231-02
+
+
7.683 0.0325" (19.51 0.083 cm)
70-229-01
To p Pla t e Dim e n sio n s
SURFACE CUT-OUT
AREA = 7.683 0.0325"
+
The cutout dimension illustrations (figures A-1 and A-2) are not
to scale and are for reference only. If you choose not to use
Extron’s metal routing template (chapter 2, Installation), the
dimensions on the illustrations will help you properly prepare
the mounting surface. The surface cutout area is the shaded area
on the diagrams. The cutout dimensions are provided.
+
+
(19.51 0.083 cm) x 5.875 0.0325"
6.375"
(16.19 cm)
+
(14.92 0.083 cm)
+
5.875 0.0325"
+
(14.92 0.083 cm)
For full size paper templates, visit the Extron Web site
Support Hotline.
0.5"
(1.3 cm)
Cut surface material
out along this line.
Tilting Plate
Cut-Out Radius:
0.25" (0.6 cm)
Top Panel
User Access (Connectors and AAP Openings)
TEMPLATE IS NOT FULL SIZE.
Fig u re A-1 — HSA 200S/HSA 200SE/ HSA 222S cu t o u t d im e n sio n s
HSA 200/222 Series • Reference Information
A-8
HSA 200/222 Series • Reference Information
A-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Re fe re n ce In fo rm a t io n , co n t ’d
HSA 200C/HSA200CE/HSA222C US Models
HSA 200/222 Series Surface Access Products
6.5" (16.5 cm)
+
+
6.000 0.0325" (15.24 0.083 cm)
SURFACE CUT-OUT
+
AREA = 6.000 0.0325"
+
(15.24 0.083 cm) diameter
Cut surface material
out along this line.
Tilting Plate
Top Panel
Appendix B
User Access (Connectors and AAP Openings)
TEMPLATE IS NOT FULL SIZE.
B
HSA 200C/HSA 200CE International Models
8.5" (21.6 cm)
8.0" (20.3 cm)
Pa cka g in g fo r Sh ip m e n t
SURFACE CUT-OUT
AREA = 8.0"
(20.3 cm) diameter
Cut surface material
out along this line.
Tilting Plate
Top Panel
User Access (Connectors and AAP Openings)
TEMPLATE IS NOT FULL SIZE.
Fig u re A-2 — HSA 200C/HSA 200CE/HSA 222C cu t o u t d im e n sio n s
HSA 200/222 Series • Reference Information
A-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Pa cka g in g fo r Sh ip m e n t
The HSA 200’s and HSA 222’s ultra-fine machined surfaces and
2.
Disconnect all cables and remove the HSA 200 or HSA 222
from the table or desk. See Removing and Replacing the
Enclosure, steps 1 through 4, in chapter 3, Maintenance and
Modifications.
moving parts make them vulnerable to damage caused by
mishandling during shipment, if they are improperly packaged.
If, for any reason, you need to return an HSA to Extron, first
contact Extron to obtain a return kit. The return kit, which
reduces the chances of damage during shipment, includes a
sturdy shipping carton and foam shells custom cut to fit the
HSA (figure B-1).
3.
4.
Place the enclosure on a flat, horizontal surface. To protect
the finish, place it on a soft cloth or rubber mat.
Install the plastic strip (part of the return kit) to protect the
flanged edges of the top of the enclosure (figure B-2).
Fig u re B-2 — In st a llin g p ro t e ct ive st rip s
5.
Open the top panel and insert the HSA 200 or HSA 222
into the custom cutout portion of one of the foam shells
(figure B-3).
Fig u re B-1 — HSA 200/HSA 222 re t u rn kit
Package an HSA for shipment as follows:
1.
Contact the Extron S3 Sales & Technical Support Hotline to
obtain a return kit. Extron will send the return kit to the
location you specify.
The flanged edges of the top of the surface
enclosure are sharp when the HSA is removed from
the table. Exercise caution when handling to
prevent personal injury.
The flanged edges of the top of the surface
enclosure are bevelled to an ultra-fine thickness of
less than 0.04 (4/100)” (approximately 1 mm).
These edges are soft and can be easily nicked or
bent. Exercise caution when handling and
mounting the enclosure. Mishandling can damage
the appearance of the enclosure.
CAUTION
Fig u re B-3 — In st a llin g t h e HSA in t o t h e fo a m
sh e ll
HSA 200/222 Series • Packaging for Shipment
B-2
HSA 200/222 Series • Packaging for Shipment
B-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Pa cka g in g fo r Sh ip m e n t , co n t ’d
6.
Place the remaining foam shell on the other side of the
HSA (figure B-4). Firmly push the foam shells together as
far as they will go to completely suspend the HSA unit.
Fig u re B-4 — HSA u n it su sp e n d e d in t h e fo a m
7.
Place the foam-protected HSA 200 or HSA 222 into the
shipping carton (figure B-5).
Fig u re B-5 — HSA in t h e sh ip p in g ca rt o n
8.
9.
Close the shipping carton and seal it with high quality
shipping tape.
Ship the HSA to Extron using a reputable shipping
company.
B-4
HSA 200/222 Series • Packaging for Shipment
Download from Www.Somanuals.com. All Manuals Search And Download.
|