Excell Precision Scale wwwexcellcomtw excell_en uploads product 200712 User Manual

EXCELL PRECISION CO., LTD.  
Weighing  
Scale  
User Manual  
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXCELL PRECISION CO., LTD.  
Preparation before Operation  
1. Avoid operating the scale in the locations where there is too much temperature changes  
and air flow, for example, the place under sunlight or air condition.  
2. Use the independent power socket to avoid the interrupt of other electronic product.  
3. When turning on the scale, do not place any object on the platter.  
4. When operating the scale, place the object on the center of the platter. For the accuracy  
of weighing, do not place the object over the range of the platter.  
5. When the low power indication (  
) lights up, the scale needs to be recharged.  
Display Description  
2
1
3
HIGH :  
OK  
LOW :  
Upper limit. To warn the object is over the setting upper limit value. And it  
means the weight excessively is high  
Value between upper and lower limit. To warn the weight of object is in the  
normal setting range.  
Lower limit. To warn the object is under the set upper limit. And it means the  
weight is not enough.  
:
kg  
:
Unit kilogram”  
lb  
:
Unit pound”  
à0ß  
Net  
:
Zeroindication  
Net Weightindication  
Low Powerindication  
(STABLE) Stableindication  
(PT) Pre Taremode  
:
:
:
:
:
61  
62  
63  
(M+) Accumulationmode  
1
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXCELL PRECISION CO., LTD.  
Keyboard Description  
UNITS  
ESC  
UNITSÞ Press the key to select the weighing unit kgor lb.”  
ESCÞ Return function.  
1.  
2.  
3.  
PRESET : Preset function for weight.  
M+ : Accumulation function for weight.  
4.  
TARE/: TAREÞ tare function; Þ to move the cursor leftward.  
5.  
6.  
7.  
PRETARE : Pre-tare function.  
RECALL : To recall the value of accumulation, tare, and pre-tare.  
CE : To clear the value of accumulation, tare, and pre-tare.  
8.  
9.  
ZERO/: ZEROÞ to re-zero weight value; Þ to move the cursor rightward.  
PRINT  
PRINTÞ printing.  
ENTER  
ENTERÞ confirmation key.  
10. BL/: BLÞ backlight setting; Þ to add number or move the menu upward.  
HOLD  
SAMPLE  
HOLDÞ printing summation  
SAMPLEÞ sampling function.  
11.  
12. G/N/: G/NÞ net and gross weight switch function; Þ to deduct number  
or move the cursor downward.  
13. ON : To turn on the scale.  
14. OFF : To turn off the scale.  
2
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXCELL PRECISION CO., LTD.  
Function & Operation  
Backlight Function  
Press BL/to select 3 backlight modes in cycle:  
.
,
.
,
.
.
Þ Auto backlight mode. When the weight is more than 10d, or  
pressing keys, the backlight will light up. After re-zeroing (the  
weight less than 10d) for 5 seconds, the backlight will be off.  
.
.
Þ Backlight always lights up.  
Þ Backlight off.  
Weighing Function  
(1). Unit Selection  
1. After turning on the scale, press  
display indications kgor lb.  
Key to select the unit kgor lb.The screen will  
UNITS  
ESC  
2. After turning off the scale, the scale will memorize the weighing unit. When turning  
on the scale next time, the weighing unit used previously will be recalled directly.  
(2). Check-weighing Function  
1. Lower limit, Upper limit, and BuzzerPresetting.  
PRINT  
ENTER  
UNITS  
ESC  
Press BL/, G/N/, TARE/,  
ZERO/,  
to input the pre-set value. Description as below:  
TARE/: To move leftward.  
ZERO/: To move rightward.  
BL/: To deduct the number by 1.  
G/N/: To add the number by 1.  
ENTER : Confirmation key.  
ESC : Return key.  
3
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXCELL PRECISION CO., LTD.  
Example:  
Lower LimitPresetting (lower limit >10d, d=division) ex.: lower limit = 20kg.  
Press PRESET key, the screen displaysï  
Press ZERO/once, the screen displays  
.
.
ï
Press BL/twice, the screen displays  
ï
.
Meanwhile, if pressing ENTER key, the screen will display 0instead of ” ”.  
Upper LimitPresetting (upper limit ³ lower limit) ex.: upper limit = 25 kg.  
Press ENTER once, the screen displaysï  
Press ZERO/once, the screen displays  
.
.
ï
.
.
Press BL/twice, the screen displays  
ï
.
.
Press ZERO/once, the screen displays  
ï
.
.
Press  
BL/5 times, the screen displays  
ï
.
.
Meanwhile, if pressing ENTER key, the screen will display 0instead of ” ”.  
BuzzerPresetting (refer to Note 1) ex.: buzzer = 22.  
Press ENTER once, the screen displaysï  
Press BL/twice, the screen displaysï  
Press ZERO/once, the screen displays  
.
.
ï
.
Press BL/twice, the screen displays  
Press ENTER once, the screen displays  
ï
.
.
.
4
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXCELL PRECISION CO., LTD.  
4 Single Point Presetting  
Lower limit only  
Method (I)  
After finished presetting lower limit, the screen displaysï  
.
. Press  
PRESET once again. If the screen displays  
.
, the single point  
presettingis completed.  
Method (II)  
After finished presetting lower limit, upper limit and buzzer, press PRESET once.  
When the screen displaysï  
.
, press RECALL twice again. At  
this time the screen displays presetting upper limit, press CE once. If the screen  
displays  
.
, the single point presettingis completed.  
Upper limit only  
After finished presetting, press PRESET once. When the screen displays  
ï
.
, press RECALL once. At this time the screen displays  
presetting lower limit, press CE once. Then the screen displays presetting upper  
limit, press ESC or RECALL to exit. If the screen displays  
single point presettingis completed.  
.
, the  
5
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXCELL PRECISION CO., LTD.  
Note 1  
C
C
A B  
A Þ 0 = Buzzer beeps when being stable; LCD indication lights up.  
1 = Buzzer beeps when being stable; LCD indication lights up without stable  
determination.  
2 = Buzzer beeps and LCD indication lights up without stable determination.  
B Þ 0 = No buzzer beep.  
1 = When its OK (the value higher than lower limit and lower than upper limit,)  
the buzzer beeps.  
2 = When the value is lower than or equal with lower limit, or higher than upper  
limit, the buzzer beeps.  
4
Single Point Presetting (lower limit only), the buzzer is fixed as:  
When the value is higher than lower limit, the buzzer beeps and  
LOW indication will be off.  
Buzzer beeps and LCD indication lights up without stable determination.  
Single Point Presetting (upper limit only), the buzzer is fixed as:  
4
When the value is higher than upper limit, the buzzer beeps  
and HIGH indication will be on.  
Buzzer beeps and LCD indication lights up without stable determination.  
6
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXCELL PRECISION CO., LTD.  
4
LCD Indication:  
ïLOW ïOK  
½ïïï½ïïï  
ïHIGH  
½
10d Lower Limit Upper Limit  
UNITS  
ESC  
¨
After entering into the presetting mode, if intended to abort, press  
key.  
2. Setting Value Recall  
Press PRESET and then RECALL Þ to recall lower limit”  
Press RECALL Þ to recall upper limit”  
Press RECALL Þ to recall buzzer”  
Press RECALL again Þ to recover the original mode.  
3. Setting Value Clear  
Press PRESET , RECALL and then CE Þ to clear lower limit”  
Press CE again Þ to clear upper limit & buzzer”  
7
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXCELL PRECISION CO., LTD.  
(3). Accumulation Function  
1. Weight Accumulation  
Place the object on the platter, after the weight display is stable, press M+ key  
to save the present weight value into memory. Meanwhile, the screen displays  
total count accumulationand then total weight accumulation, and the  
accumulation (M+) indication 6will be flashing. After 3 seconds, the screen will  
display the weight on platter, and the accumulation (M+) indication 6lights up.  
If the weight is unstable after pressing M+ key, the screen will display “ ”.  
4
4
The scale can be continuous to accumulate the next weight without re-zeroing.  
When the changes of weight on the platter is higher than ±10d, press M+  
key, after being stable, its capable to save the weight into memory.  
Accumulation count is up to 9999, but display digit is up to 6.  
2. Accumulation Clearing  
¨ Press RECALL and then CE to clear all the accumulation.  
¨ Accumulation will be cleared automatically after turning off.  
3. Accumulation Recall  
While pressing RECALL key, the screen will display total count accumulation,  
and then total weight accumulation. It will be back to the original mode after  
accumulation (M+) light 6flashing for 3 seconds. If no accumulation, it will be back  
to the original mode after the screen displays total count accumulation.  
(4). Zero Function  
If zero drift happens during operating the scale, which means no objects on platter,  
but the screen displays tiny weight value, press ZERO/to re-zero. Meanwhile,  
the screen will display the zero (à0ß ) indication.  
(5). Net / Gross Switch  
If it has tare or pre-tare at present, press G/N/and the screen displays the gross  
value. Meanwhile, all the keys are no function, and press G/N/to return displaying  
net weight value.  
8
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXCELL PRECISION CO., LTD.  
(6). Low Voltage Auto Power off Function  
Œ When the voltage of batteries is lower than 5.6v±0.1 v, it turns off backlight and  
the screen displays the battery symbol to intimate it needs to be recharged.  
When the voltage of batteries is lower than 5.4v±0.1 v, it would auto power off;  
meanwhile, if turning on again, the screen would not be countdown and only  
displays the battery symbol. It would auto power off after 5 seconds, and it  
needs to recharge immediately.  
When the voltage of batteries is lower than 5.2v±0.1 v, it cant be turned on and  
please recharge immediately.  
(7). Tare Function  
1. Weight of Unknown Container ( TARE/)  
Œ Place the container on platter. After being stable, press TARE/key to  
re-zero. The screen will display net weight (Net) indication.  
Place the object into the container, and the scale will display the net weight of it.  
Tare valueclearing  
Remove both the container and the object on the platter; the scale displays the  
negative value of the container. Meanwhile, press TARE/again to clear  
tare value,and the net weight (Net) indication disappears.  
Tare valuerecall  
Press RECALL and then TARE/←  
Þ The screen displays tare value.  
4
4
Capable of continuously taring until the summation of tare and pre-tare value  
equals the capacity of the scale.  
Continuously tare function Þ both continuously increasing or decreasing  
weight on platter are acceptable by pressing TARE/key.  
9
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXCELL PRECISION CO., LTD.  
2. Weight of Known Container ( PRETARE )  
Œ Press PRETARE key, and the screen displays ï  
.
. Use  
BL/, G/N/, TARE/, ZERO/, ENTER , ESC keys to input  
the presetting value. The functions are described as below:  
Input the weight of container. After finished, the screen displays the negative  
value of the container, and the net weight (Net) and pre-tare (PT) indications light  
up.  
Place both the object and container on platter, and the scale displays the net  
weight of it.  
Pre-tare valueclearing  
Press RECALL , PRETARE and then CE Þ to clear pre-tarevalue.  
The scale will be re-zeroed and net weight (Net) and pre-tare (PT) indications  
disappear.  
Pre-tarerecall  
Press RECALL and then PRETARE Þ the screen displays pre-tare”  
value.  
4
4
Pre-tare function is not available under tare mode.  
If it has segments, pre-tarevalue cant be larger than the segment value.  
10  
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXCELL PRECISION CO., LTD.  
Appendix: 7 Segment Display Characters  
7 segments  
letter  
7 segments  
letter  
7 segments  
letter  
Digit  
0
Alphabet  
Alphabet  
N
A
1
2
3
4
5
6
7
8
9
B
C
D
E
F
G
H
I
O
P
Q
R
S
T
U
V
W
X
Y
Z
J
K
L
M
11  
Weighing  
ZSME300000036  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cooper Lighting Indoor Furnishings BA SERIES User Manual
Cornelius Beverage Dispenser FlavorFusion Series User Manual
Craftsman Lawn Mower 917385123 User Manual
Cuisinart Blender WOK 703C User Manual
Danby Dehumidifier DDR3008EE User Manual
DVS DVD Player VXM 2000 User Manual
Electro Voice Portable Speaker DMC 1152B User Manual
EverFocus Security Camera EPD200 User Manual
Faber Ventilation Hood Dama Isola User Manual
Frigidaire Convection Oven FGB24T3EB User Manual