EVC MH LED
General Information
Unpacking: Thank you for purchasing the EVC MH LED by Elation
Professional®. Every EVC MH LED has been thoroughly tested and
has been shipped in perfect operating condition. Carefully check the
shipping carton for damage that may have occurred during shipping.
If the carton appears to be damaged, carefully inspect your fixture for
any damage and be sure all equipment necessary to operate the unit
has arrived intact. In the event damage has been found or parts are
missing, please contact our toll free customer support number for fur-
ther instructions. Please do not return this unit to your dealer without
contacting customer support first.
EVC MH LED
Introduction: The EVC MH LED by Elation Professional® is a unique
twelve channel DMX controllable moving head video camera, designed
to spotlight almost anything and project it onto a video wall or TV. An
array of 48 total Cool and Warm White LED’s allow you to customize
to different skin tones and ambient light in a room so that the EVC MH
LED always projects the best images. The EVC MH LED is compact
and light weight so that it is very discreet and easy to transport and
mount. The EVC MH LED is ideal for use at corporate events, wedding
receptions, nightclubs, school dances, or anywhere that you wish to
put someone in the spotlight.
Customer Support: Elation Professional® provides a toll free cus-
tomer support line, to provide help and to answer any question should
you encounter problems during your set up or initial operation. You
ments or suggestions. Service Hours are Monday through Friday 8:00
a.m. to 4:30 p.m. Pacific Standard Time.
Voice:
Fax:
(323) 582-3322
(323) 832-9142
E-mail:
Warning! To prevent or reduce the risk of electrical shock or fire, do
not expose this unit to rain or moisture.
User Instructions
Warning! This may cause severe eye damage. Avoid looking directly
into the light source at all times!
3/12
Download from Www.Somanuals.com. All Manuals Search And Download.
EVC MH LED
Set Up
EVC MH LED
Set Up
Power Supply: The Elation Professional® EVC MH LED contains a
automatic voltage switch, which will auto sense the voltage when it is
plugged into a power source. With this switch there is no need to worry
about the correct power voltage, this unit can be plugged in anywhere.
Notice: Be sure to follow figures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR’s outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of
communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX
fixtures (most controllers only have a DATA “OUT” terminal).
COMMON
1
2
1
2
DMX +
DMX -
DMX512 OUT
3-PIN XLR
DMX512 IN
3-PIN XLR
3
3
Figure 2
DMX Linking: DMX is a language allowing all makes and models
of different manufactures to be linked together and operate from a
single controller, as long as all fixtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using
several DMX fixtures try to use the shortest cable path possible. The
order in which fixtures are connected in a DMX line does not influence
the DMX addressing. For example; a fixture assigned a DMX address
of 1 may be placed anywhere in a DMX line, at the beginning, at the
end, or anywhere in the middle. Therefore, the first fixture controlled
by the controller could be the last fixture in the chain. When a fixture
is assigned a DMX address of 1, the DMX controller knows to send
DATA assigned to address 1 to that unit, no matter where it is located
in the DMX chain.
XLR Female Socket
XLR Male Socket
1 Ground
XLR Pin Configuration
Pin 1 = Ground
2 Cold
2 Cold
1 Ground
Pin 2 = Data Compliment (negative)
3 Hot
3 Hot
Pin 3 = Data True (positive)
Figure 3
Special Note: Line Termination. When longer runs of cable are
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave
Operation): The EVC MH LED is a 12 channel DMX unit. The DMX
address is set electronically using the controls on the front panel of
the unit. Your unit and your DMX controller require
a approved DMX-512 110 Ohm Data cable for data
input and data output (Figure 1). We recommend
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
Figure 4
Accu-Cable DMX cables. If you are making your
own cables, be sure to use standard 110-120 Ohm
shielded cable (This cable may be purchased at
almost all professional sound and lighting stores).
Your cables should be made with a male and
female XLR connector on either end of the cable. Also remember that
Figure 1
DMX cable must be daisy chained and cannot be split.
Download from Www.Somanuals.com. All Manuals Search And Download.
EVC MH LED
Set Up
EVC MH LED
System Menu
5-Pin XLR DMX Connectors. Some manufactures use 5-pin DMX-
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX
fixtures may be implemented in a 3-pin DMX line. When inserting stan-
dard 5-pin data cables in to a 3-pin line a cable adaptor must be used,
these adaptors are readily available at most electric stores. The chart
below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor
3-Pin XLR Female (Out)
5-Pin XLR Male (In)
Ground/Shield
Pin 1
Pin 1
Data Compliment (- signal)
Data True (+ signal)
Not Used
Pin 2
Pin 3
Pin 2
Pin 3
Pin 4 - Do Not Use
Pin 5 - Do Not Use
Not Used
Download from Www.Somanuals.com. All Manuals Search And Download.
EVC MH LED
System Menu
EVC MH LED
System Menu
again. Press ENTER when you have made your desired setup.
ADDR - DMX Address Setting.
1. Press the MENU, UP, or DOWN buttons until “ADDR” is dis-
MANU - In this mode you are able to manually test the
various functions; Pan and Tilt and Pan/Tilt Speed, color
temperature, LED intensity, zoom and focus.
played, press ENTER.
2. The current address will now be displayed and flashing. Use
the UP and DOWN buttons to find your desired address. Once
you have found your desired DMX address press ENTER then
press and hold the MODE button for at least 3 seconds to set
the address.
1. Press the MENU button until “MANU” is displayed, press
ENTER. One of the submenus listed below will be displayed.
2. Use the UP and DOWN buttons to find the function that you
would like to test. When you have found it press ENTER.
TLTN - Tilt Inversion
3. Once you have entered the submenu, use the UP and DOWN
buttons to adjust the values and test the function.
1. Press the MENU button until “TLTN” is displayed, press
ENTER. Either NO or 1 will be displayed.
4. Once you are finished, press the MENU button to exit.
2. To activate the Tilt inversion press the UP or DOWN buttons
until I is displayed, press ENTER to confim. To deactivate Tilt
inversion, select No and press Enter.
SUBMENUS:
PAn - Test the Pan function.
PAnF - Test the Fine Pan.
tiL - Test the Tilt function.
LED - With this function you can have the LED display
tiLF - Test the Fine Tilt.
turn off after 10 seconds.
SPed - Test the Pan and Tilt Speed.
CoLt - Test the Color Temperature.
UdIn - Test the Warm White intensity.
Cdln - Test the Cool White intensity.
Zon - Test the Zoom.
1. Press the MENU button until “LED” is displayed, press
ENTER.
2. The display will show either “ON” or “OFF”. Press the UP or
DOWN buttons to select “ON” to keep the LED display on at
all times, or “OFF” to have the LED display switch off after 10
seconds.
3. Press ENTER to confirm.
Foc - Test the Focus.
DISP - This function will reverse the display 180º.
VER - With this function you can display the version soft-
ware of the unit.
1. Press the MENU button until “DISP” is displayed, press
ENTER.
1. Press the MENU button until “VER” is displayed, press
ENTER.
2. Press ENTER to “flip” the display. Press ENTER to “flip” it
Download from Www.Somanuals.com. All Manuals Search And Download.
EVC MH LED
System Menu
EVC MH LED
Operation
Universal DMX Control: This function allows you to use a Elation®
universal DMX-512 controller to control the chases and patterns,
dimmer and strobe. A DMX controller allows you to create unique
programs tailored to your individual needs.
2. The software version will now be displayed. Press MENU to
exit
1. The EVC MH LED is a 12 channel DMX fixture. See page 13 for
detailed description of the DMX values and traits.
2. To control your fixture in DMX mode, follow the set-up procedures
on pages 5-7 as well as the set-up specifications that are includ-
ed with your DMX controller.
3. Use the controller’s faders to control the various DMX fixture traits.
4. This will allow you to create your own programs.
5. Follow the instruction on page 9 to set the DMX address.
6. For longer cable runs (more than a 100 feet) use a terminator on
the last fixture.
RSET - Use this function to reset the unit.
1. Press the MENU button until “RSET” is displayed, press
ENTER.
2. The fixture will now reset.
7. For help operating in DMX mode consult the manual included
with your DMX controller.
Master-Slave Operation This function will allow you to link up to 16
units together and operate without a controller. In Master-Slave opera-
tion one unit will act as the controlling unit and the others will react to
the controlling units programs. Any unit can act as a Master or as a
Slave.
1. Using approved DMX data cables, daisy chain your units togeth-
er via the XLR connector on the rear of the units. Remember the
Male XLR connector is the input and the Female XLR connector
is the output. The first unit in the chain (master) will use the female
XLR connector only - The last unit in the chain will use the male
XLR connector only. For longer cable runs we suggest a termina-
tor at the last fixture.
2. The slave units will now follow the Master unit.
Download from Www.Somanuals.com. All Manuals Search And Download.
EVC MH LED
DMX Traits
EVC MH LED
Connections
Use a BNC video cable or RCA video cable, with RCA/BNC
adaptor, to connect to a video converter or source such as Ela-
tions’ EPV Image VSC.
Download from Www.Somanuals.com. All Manuals Search And Download.
EVC MH LED
Fuse Replacement
EVC MH LED
Warranty
2-YEAR LIMITED WARRANTY
Locate and remove the unit’s power cord. Once the cord has been
removed located the fuse holder located inside the power socket.
Insert a flat-head screw driver into the power socket and gently pry
out the fuse holder. Remove the bad fuse and replace with a new one.
The fuse holder has a built-in socket for a spare fuse be sure not to
confuse the spare fuse with active fuse.
A. Elation® Architectural hereby warrants, to the original purchaser, Elation®
Professionals® products to be free of manufacturing defects in material and
workmanship for a period of two years (730 days) from the date of purchase. This
warranty shall be valid only if the product is purchased within the United States
of America, including possessions and territories. It is the owner’s responsibility
to establish the date and place of purchase by acceptable evidence, at the time
service is sought.
EVC MH LED
Cleaning
B. For warranty service, send the product only to the Elation® Professionals®
factory. All shipping charges must be pre-paid. If the requested repairs or ser-
vice (including parts replacement) are within the terms of this warranty, Ela-
tion® Professionals® will pay return shipping charges only to a designated point
within the United States. If the entire instrument is sent, it must be shipped in
its original package. No accessories should be shipped with the product. If any
accessories are shipped with the product, Elation® Professionals® shall have no
liability whatsoever for loss of or damage to any such accessories, nor for the
safe return thereof.
Fixture Cleaning: Due to fog residue, smoke, and dust cleaning
the internal and external optical lenses and mirror should be carried
out periodically to optimize light output. Cleaning frequency depends
on the environment in which the fixture operates (I.e. smoke, fog
residue, dust, dew). In heavy club use we recommend cleaning on a
monthly basis. Periodic cleaning will ensure longevity, and crisp out-
put.
C. This warranty is void if the serial number has been altered or removed; if the
product is modified in any manner which Elation® Professionals® concludes,
after inspection, affects the reliability of the product; if the product has been
repaired or serviced by anyone other than the Elation® Professionals® factory
unless prior written authorization was issued to purchaser by Elation® Profes-
sionals®; if the product is damaged because not properly maintained as set forth
in the instruction manual.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Use a brush to wipe down the cooling vents and fan grill.
3. Clean the external optics with glass cleaner and a soft cloth every
D. This is not a service contract, and this warranty does not include mainte-
nance, cleaning or periodic check-up. During the period specified above, Ela-
tion® Professionals® will replace defective parts at its expense, and will absorb
all expenses for warranty service and repair labor by reason of defects in mate-
rial or workmanship. The sole responsibility of Elation® Professionals® under
this warranty shall be limited to the repair of the product, or replacement thereof,
including parts, at the sole discretion of Elation® Professionals®. All products
covered by this warranty were manufactured after January 1, 1990, and bear
identifying marks to that effect.
20 days.
4. Clean the internal optics with glass cleaner and a soft cloth every
30-60 days.
5. Always be sure to dry all parts completely before plugging the unit
back in.
EVC MH LED
Trouble Shooting
E. Elation® Professionals® reserves the right to make changes in design and/or
improvements upon its products without any obligation to include these changes
in any products theretofore manufactured.
Trouble Shooting: Listed below are a few common problems that
you may encounter, with solutions.
F. No warranty, whether expressed or implied, is given or made with respect to
any accessory supplied with products described above. Except to the extent
prohibited by applicable law, all implied warranties made by Elation® Profession-
als® in connection with this product, including warranties of merchantability or
fitness, are limited in duration to the warranty period set forth above. And no war-
ranties, whether expressed or implied, including warranties of merchantability or
fitness, shall apply to this product after said period has expired. The consumer’s
and or Dealer’s sole remedy shall be such repair or replacement as is expressly
provided above; and under no circumstances shall Elation® Professionals® be
liable for any loss or damage, direct or consequential, arising out of the use of,
or inability to use, this product.
No light output from the unit;
1. Be sure you have connected your unit into a standard wall outlet.
2. Be sure the external fuse has not blown. The fuse is located on
the rear panel of the unit.
3. Be sure the fuse holder is completely and properly seated.
G. This warranty is the only written warranty applicable to Elation® Profession-
als® Products and supersedes all prior warranties and written descriptions of
warranty terms and conditions heretofore published.
Download from Www.Somanuals.com. All Manuals Search And Download.
EVC MH LED
Notes
EVC MH LED
Notes
Download from Www.Somanuals.com. All Manuals Search And Download.
EVC MH LED
Specifications
Model:
Voltage:
LED:
EVC MH LED
100V ~ 240V 50~60Hz
48 LEDs (24 Cool White & 24 Warm
White)
Power Consumption:
Beam Angle:
36W
60 Degrees
Dimensions:
8.14”(L) x 8.22”(W) x 9.6”(H)
207mm x 209mm x 246mm
8.3 Lbs. / 3.8 kgs.
1 Amp
Weight:
Fuse:
Duty Cycle:
DMX:
Working Position:
Warranty:
None
12 DMX Channels
Any Safe, Secure Position
2 Year (730 days)
Auto Sensing Voltage: This fixture contains a automatic voltage
switch, which will auto sense the voltage when it is plugged into
the power source.
Please Note: Specifications and improvements in the design of
this unit and this manual are subject to change without any prior
written notice.
©Elation Professionals®
A Division of the AmericanDJ® Group of Companies
World Headquarters:
6122 S. Eastern Ave. Los Angeles, CA 90040 USA
Tel: 323-582-3322 Fax: 323-832-9142
American DJ Europe
Junostraat 2
6468 EW Kerkrade
Netherlands
Tel: +31 45 546 85 00 / Fax: +31 45 546 85 99
Download from Www.Somanuals.com. All Manuals Search And Download.
|