Dynasty Spas Hot Tub GS500 User Manual

VS500/501 GS500/501 Control Reference Card  
Circ Operation  
Initial Start-up  
When your spa is first actuated, it will go into Priming mode, indicated by “ .” Please see the M-7 Installation Instruction Manual  
for complete instructions on Power-up and Pump Priming. The Priming mode will last for less than 5 minutes (press "Temp" or  
"Set" to skip Priming Mode) and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode.  
Your system has a 24-hour circ pump. The circ pump  
and the ozone generator run continuously with the  
exception of shutting off for 30 minutes at a time in  
hot environments.  
Mode  
Mode is changed by pressing the “Temp” or “Set” button, then  
pressing the “Light” button.  
Standard Mode is programmed to maintain the desired  
temperature. Note that the last measured spa temperature  
displayed is current only when the circ pump has been running  
for at least 2 minutes. “ ” will be displayed momentarily when  
you switch into Standard Mode.  
Temp/Set (80°F - 104°F / 26°C - 40°C)  
The start-up temperature is set at 100F°/37°C. The last  
measured temperature is constantly displayed on the LCD.  
Note that the last measured spa temperature displayed is  
current only when the circ pump has been running for at  
least 2 minutes.  
Economy Mode heats the spa to the set temperature only  
during filter cycles. “ ” will display solid when temperature  
is not current, and will alternate with temperature when  
temperature is current.  
To display the set temperature, press the “Temp” or “Set”  
pad once.  
To change the set temperature, press the pad a second time  
before the LCD stops flashing. Each press of the “Temp” or “Set”  
pad will continue to either raise or lower the set temperature.  
If the opposite direction is desired, release the pad and let the  
display revert to the current water temperature. Press the pad to  
display the set temperature, and again to make the temperature  
change in the desired direction.  
After three seconds, the LCD will stop flashing and display the  
current spa temperature.  
Note: If there is not a blower on the system, an alternate panel with  
separate "Up" and "Down" buttons in place of a "Set" or "Temp" button  
may be used. Simply press "Up" or "Down" where a "Temp" or "Set"  
button press is indicated.  
Sleep Mode heats the spa to within 20°F/10°C of the set  
temperature only during filter cycles. “ ” will display solid  
when temperature is not current, and will alternate with  
temperature when temperature is current.  
Preset Filter Cycles  
The first filter cycle begins 6 minutes after the spa is energized.  
The second filter cycle begins 12 hours later. Filter duration is  
programmable for 2, 4, 6, 8 hours or for continuous filtration  
(indicated by “ ”). The default filter time is 2 hours.  
To program, press “Temp” or “Set,” then “Jets.” Press “Temp”  
or “Set” to adjust. Press “Jets” to exit programming.  
At the beginning of each filter cycle the blower purges for 30  
seconds; the pump purges for 5 minutes. The only effect filter  
duration has is: 1) During the filter, the circ pump never turns  
off, and 2) In Economy and Sleep Modes, heating only occurs  
during the filter cycle.  
Jets  
Touch the “Jets” button once to turn pump 1 on or off, and to  
shift between low and high speeds (if equipped). If left running,  
the low speed of the pump will automatically turn off after  
4 hours, and the high speed will automatically turn off after  
15 minutes.  
Freeze Protection  
If the temperature sensors detect a drop to below 44°F/6.7°C  
within the heater, the pump and blower will automatically  
activate to provide freeze protection. The equipment stays on  
until 4 minutes after the sensors detect that the spa temperature  
has risen to 45°F/7.2°C or higher. In colder climates, an  
optional additional freeze sensor may be added to protect against  
freeze conditions that may not be sensed by the standard sensors.  
Aux freeze sensor protection acts similarly except with the  
temperature thresholds determined by the switch and without a  
4-minute delay in turnoff. See your dealer for details.  
Blower (optional on VS501 or GS501)  
This button is used to turn the blower on and off. If left on, the  
blower automatically turns off after 15 minutes.  
Jets 2 (optional on VS501 or GS501)  
If your system has a pump 2 installed instead of a blower, it  
behaves exactly like a blower would.  
Light  
Press the “Light” button to turn the light on and off. If left on,  
the light automatically turns off after 4 hours.  
(over)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Craftsman Snow Blower 247885550 247885680 User Manual
Cyclades Server TS100 V2 User Manual
D Link Printer DPR 1020 User Manual
Dyson Camera Accessories DC44 User Manual
Earthquake Sound Car Speaker DB R User Manual
Electro Voice Microphone PL80c User Manual
FEIN Power Tools Grinder Belt Grinder User Manual
Fender Guitar 19479 User Manual
Fisher Price Power Screwdriver V2760 User Manual
Gardena Water Pump T 380 User Manual