DYMO Five-Pound USB Postal Scale  
The DYMO Five-Pound USB Postal Scale weighs  
items up to five pounds (2.2 kg) in 0.1 ounce  
(3 g) increments. This document provides  
instructions for using the scale.  
Thumb slot to  
lift platform  
Installing the Scale  
The scale is powered through a USB port on  
your computer. When not connected to your  
computer, the scale can be powered by an  
optional 9-volt battery.  
Tare  
To install the scale  
1. Unpack the scale.  
Kg/Lb  
Hold  
Power LCD  
Display  
2. Set the scale on a firm, flat surface.  
3. Plug the USB cable into an available USB port.  
The scale is automatically recognized by your computer.  
When connecting the scale through a USB hub, always use a powered hub.  
!
Inserting the Battery  
The scale uses one 9-volt alkaline battery. The scale  
automatically turns off after two minutes of inactivity.  
To insert the battery  
1. Disconnect the USB cable from the computer or  
USB hub.  
2. Turn the scale over.  
3. Remove the battery compartment cover by sliding  
the cover toward the back of the scale.  
4. Attach a 9-volt battery to the battery terminals.  
5. Insert the battery into the compartment and replace the cover.  
Remove the battery if the scale will not be used for a long period of time.  
!
Turning on the Power  
When the scale is powered through the USB port, the Power button has no effect. The power is  
on when your computer is running.  
To turn the scale on  
Press the Power button on the front of the scale to turn the scale on and off.  
When the scale is first plugged in or turned on, wait a few seconds for the scale to stabilize  
before weighing items. The display shows 88.8.8.8.8 for a few seconds and then 0.0 when  
ready.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Scale  
Always wait for 0.0 to display before placing an item on the scale  
platform.  
After placing an item on the scale, wait for several seconds for the  
OZ  
LB  
°
weight to appear. When the scale is ready, a  
the weight.  
{
appears to the left of  
To weigh an item  
Place an item on the scale platform.  
Lift the top of the scale platform to a 90-degree position  
and place large envelopes in an upright position on the  
platform  
Using the Tare Button  
You can weigh small items or items that cannot be easily  
placed on the scale platform by placing the items in a  
container and using the Tare button to eliminate the weight  
of the container.  
Pressing the Tare button always returns the scale to zero.  
To use the Tare button  
!
1. Place an empty container on the platform.  
2. When the scale is ready, press the Tare button. The display is set to zero.  
3. Place the items to be weighed in the container.  
The display shows the weight of the items, without the weight of the container.  
4. After removing the container, press Tare to reset the scale to zero.  
Using the Hold Button  
When an item being weighed extends over the front of the scale and you cannot see the  
display, you can freeze the display using the Hold button.  
To use the Hold button  
1. Place the item on the scale.  
2. After a few seconds, press the Hold button and remove the item from the scale.  
The weight continues to be displayed for about six seconds.  
Changing the Units of Measure  
Your scale can display weight in English (pounds) or metric (kilograms) units. The default unit  
of measure is English.  
To change the units of measure  
Press the Kg/Lb button to toggle between English and metric units.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Caring for the Scale  
With proper care and handling, your scale will give you years of service. Keep the following in  
mind when using your scale:  
Your scale works best when operated and stored at normal room temperature. Avoid  
lengthy exposure to extreme heat or cold.  
Only operate the scale on a stable, vibration free surface.  
Exposure to dust, dirt, moisture, vibration, and air currents; and proximity to other  
electronic equipment can affect the reliability and accuracy of your scale.  
Using the scale in proximity to wireless devices, such as mobile phones, can cause the scale  
display to fluctuate when the device is in use.  
Although this scale is designed to be quite durable, gently place items to be weighted on to  
the platform. Avoid rough treatment as this may permanently damage the internal sensor  
and void your warranty.  
You can permanently damage the scale by placing significantly overweight items on the  
scale platform.  
Avoid shaking, dropping, or otherwise shocking the scale. This is a precision instrument and  
MUST BE HANDLED WITH EXTREME CARE.  
The scale has been calibrated at the factory and will not need to be calibrated again.  
Technical Specifications  
Capacity  
5.0 pounds (2.2 kg)  
Resolution  
Accuracy  
0.1 oz. (1 g)  
0.1 oz. ( 3 g)  
Units  
lb./oz. (kg/g)  
Auto-off  
After two minutes of inactivity  
50° - 86° F (10° - 30° C)  
USB 2.0 Low Speed HID Scale Device  
USB or 9-volt alkaline battery  
Operating Temperature  
Interface  
Power  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
Problem/Error Message  
Solution  
No display  
Ensure the scale is connected to the computer using the USB  
cable, or replace the battery.  
If not connected to the computer, press the Power button.  
Lo or low battery indicator is displayed Replace the 9-volt battery.  
CAL is displayed  
Scale is in calibration mode. Press the Power button to return to  
normal mode.  
Negative number is displayed  
ErrE is displayed  
A Tare value is displayed as a negative number when the items  
are removed from the scale. Press Tare to reset the scale to zero.  
The item on the scale platform exceeds the maximum capacity  
of the scale. Remove the item immediately to prevent damage  
to the scale.  
Display reads 0.0 with an item on the  
platform  
This can happen because:  
The Tare button was pressed while an item was on the scale.  
Your computer went into Sleep or Standby mode with an  
item on the scale.  
Power to the scale was disconnected or turned off and then  
on again with an item on the scale.  
In all of these cases, remove the item from the platform and  
press the Tare button to return the display to 0.0  
.
Warranty  
Your DYMO® USB Scale comes with a warranty against defects in materials, design, or workmanship, for one year from the  
original date of purchase, when used in accordance with all operating instructions. Normal wear and tear is not covered,  
nor is excessive use, abuse or damage caused by a user either intentionally or accidentally.  
EXCEPT AS PROVIDED HEREIN, DYMO MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, AND DYMO SPECIFICALLY  
EXCLUDES WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DYMO’S LIABILITY UNDER  
THIS WARRANTY SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE SCALE. DYMO SHALL NOT BE RESPONSIBLE FOR  
ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, WHETHER OR NOT FORESEEABLE.  
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE  
TO STATE AND COUNTRY TO COUNTRY.  
Material Return Authorization number and further instructions to return your product.  
Certification  
This device has been tested and complies with the requirements of:  
Model #40149  
UL 1950  
FCC Part 15 Class B  
EN60950: Low Voltage Directive Product Safety  
EN55022: Radiated and Conducted Emissions B  
EN55024: ITE Products Immunity Requirements  
RoHS 2002/95/EC  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC Compliance  
This equipment has been tested and found to comply with the limits for a Class B computer peripheral, pursuant to part  
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a  
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and  
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to  
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to  
try to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device  
may not cause harmful interference, and (2) this device must accept any interference received, including interference that  
may cause undesired operation.  
Electrostatic Discharge Precautions  
Electrostatic discharge (Static Electricity or ESD) can cause damage to any electronic device, including the scale. To avoid  
damage, follow these simple steps:  
Always disconnect the scale from your computer or USB hub when changing the battery.  
Always discharge any accumulated static electricity from yourself before connecting the scale to your computer or  
USB hub. If your computer uses a three-pin, grounded connector, you can do this by touching the metal case of your  
computer. As an alternative, try touching a cold water faucet.  
Environmental Information  
The equipment that you bought has required the extraction and use of natural resources for its production. It may  
content hazardous substances for the health and the environment.  
In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural  
resources, we encourage you to use the appropriate take-back systems. Those systems will reuse or recycle most of the  
materials of your end life equipment in a sound way.  
The crossed-bin symbol marked in your device invites you to use those systems.  
If you need more information on the collection, reuse and recycling systems, please contact your local or regional waste  
administration. You can also contact us for more information on the environmental performances of our products.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
©2006 DYMO  
A Newell Rubbermaid Company  
DYMO Corporation  
44 Commerce Road  
Stamford, CT 06902  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cooper Lighting Landscape Lighting GMA25SWWAR User Manual
Cooper Lighting Landscape Lighting STL StairLite User Manual
Curtis Flat Panel Television LCD3718A User Manual
Desa Stove FSVYD18N User Manual
Dynacord Telephone DTI 2000 User Manual
Elation Professional Landscape Lighting LED 36 User Manual
Extron electronic Network Card IPL T SFI244 User Manual
Fender Guitar 193560 User Manual
GE Air Conditioner AZ29E12EAC User Manual
GE Dishwasher GHD3500 series GSD3400 series User Manual