line from the power supply panel.  
5.Connect the black LOAD lead from the thermostat to the  
line lead on the heater.  
6.Connect the N Neutral (or L2) line to the remaining line  
of the heater.  
7.Secure the ground wire to the ground screw provided in  
the outlet box.  
8.Ensure that all connections are tight.  
9.Insert wires into the outlet box taking care not to damage  
the sensing device or wiring.  
10.Remove the thermostat cover by grasping the cover by  
the sides and pulling it away from the  
thermostat base.  
11.Mount the thermostat base into the wall box and secure  
using the two supplied screws.  
NOTE:  
NOTE:  
Clean, attractive style suits any decore  
wall-mount design sits flush against wall  
Includes both oC and oF control dials  
Do not over tighten mounting screws  
11.Replace thermostat cover.  
L1 FROM  
POWER  
SUPPLY  
SPECIFICATIONS  
Electrical Ratings:  
Electrical Ratings  
0 - 2640 watts max. at  
120 volts (22 amps)  
0 - 4576/5280 watts at  
208/240 volts (22 amps)  
0 - 4986 watts at  
L2 FROM  
POWER  
SUPPLY  
RED  
LINE  
RED  
LINE  
LOAD  
BLACK  
277 volts (18 amps)  
LOAD  
BLACK  
Sensing Element:  
Bimetal  
Do not over tighten mounting screws  
12.Replace thermostat cover.  
Temperature Operating Range:  
5o - 35oC  
WIRE  
CONNECTOR  
41o - 95oF  
NETURAL  
L1 FROM  
FROM  
Approvals:  
THERMOSTAT  
OPERATION  
HEATER  
POWER  
POWER  
Underwriters Laboratories Inc No.: E105830  
Canadian Standards Association No.: LR30410  
SUPPLY  
SUPPLY  
To adjust the temperature to your individual requirements,  
turn the thermostat control clockwise all the way to turn  
on the heater. When the room reaches the desired  
temperature, turn the thermostat knob counter clockwise  
until you hear a click. Leave in this position to maintain  
the room temperature at this setting. For additional heat,  
turn clockwise until you hear the click again and the  
heater will turn on.  
LINE RED  
Mounting:  
Mounts directly into a standard 2 x 4 inch vertical electrical  
outlet box  
LOAD  
BLACK  
WIRE  
CONNECTOR  
For single pole models:- Turning the knob fully counter  
clockwise will set the temperature rating to 5oC (41oF).  
For double pole models:-Turning the knob fully counter  
clockwise will disconnect the power to the heater.  
THERMOSTAT  
HEATER  
DOUBLE POLE THERMOSTAT INSTALLATION  
WARNING  
The installation of the thermostat must comply with the  
applicable Local and/or National Electrical Codes and  
utility requirements. This installation should be entrusted  
to duly qualified personnel where required by law.  
WARNING  
INDEX  
OUTLET  
BOX  
Ensure that all wiring connections to the thermostat are  
correct and tight to prevent electrical shorts. Use the  
appropriate wire to meet local and national electrical codes  
for rated power consumption.  
COVER  
PLATE SCREW  
BASE  
SINGLE POLE THERMOSTAT INSTALLATION  
WARNING  
The installation of the thermostat must comply with the  
applicable Local and/or National  
Electrical Codes and utility requirements. This installation  
should be entrusted to duly qualified personnel where  
required by law.  
1.Disconnect power supply to prevent electrical shock or  
product damage.  
2.Run line voltage wiring to the thermostat location.  
3.Do not remove the thermostat cover.  
4.Connect the black LOAD leads on the thermostat to the  
leads on the heater.  
INDEX PLATE REMOVAL  
Using a small flat screwdriver or other suitable tool gently  
pry up on one of the slots located on the index plate. To  
install line up the index plate pins with the holes in the  
thermostat knob and push until the index plate is flush  
with the thermostat knob.  
5.Connect the red LINE leads on the thermostat to the line  
leads from the power supply panel.  
6.Ensure that all connections are tight.  
7.Insert wires into the outlet box taking care not to damage  
the sensing device or wiring.  
8.Secure the ground wire to the ground screw provided in  
the outlet box.  
9.Remove the thermostat cover by grasping the cover by  
the sides and pulling it away from the thermostat base.  
10.Mount the thermostat into the wall box and secure  
using the two supplied screws.  
WARNING  
Ensure that all wiring connections to the thermostat are  
correct and tight to prevent electrical shorts. Use the  
appropriate wire to meet local and national electrical codes  
for rated power consumption.  
1.Disconnect power supply to prevent electrical shock or  
product damage.  
2.Run line voltage wiring to the thermostat location.  
3.Do not remove the thermostat cover.  
4.Connect the red LINE lead on the thermostat to the L1  
7207610100rev00  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Coleman Gas Grill 5400 LP User Manual
Coleman Tent 2000001592 User Manual
Cooper Lighting Landscape Lighting GAR User Manual
Danby Microwave Oven DMW111KWDB User Manual
Delkin Devices Home Security System PC585 User Manual
Earlex Heat Gun HG1200 User Manual
Edelbrock Water Pump 8805 User Manual
Fortinet Network Card FSAE User Manual
Generac Power Systems Portable Generator 09843 2 User Manual
Global Machinery Company Saw LS236LS User Manual