Dimplex Humidifier WFC 3NB User Manual

Installation and Operating Instructions  
Dimplex Wall-mounted Fan Convector  
08/18724/2 Issue 2  
Models : WFC 3NB and WFC 3NS  
575mm  
120mm  
Dimensions  
Model(s)  
WFC 3NB  
WFC 3NS  
Specification  
3kW, Switch, Thermostat & Neon - Black  
3kW, Switch, Thermostat & Neon - Silver  
350mm  
Fig. 1  
350mm min  
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.  
Installation  
IMPORTANT SAFETY ADVICE  
Before undertaking installation work, ensure the electricity  
supply is disconnected from any relevant fixed wiring.  
WARNING – THIS APPLIANCE MUST NOT BE USED IN  
A BATHROOM.  
Supply cable is not provided with this appliance, and a  
competent electrician should therefore install it.  
The appliance must be fitted horizontally with the cable or  
conduit entry at bottom right. It should be mounted such that the  
underside is at least 350mm above the floor and the top of the  
heater is 150mm below any overhanging shelf or obstruction.  
WARNING – DO NOT USE THIS HEATER IN THE  
IMMEDIATE SURROUNDINGS OF A BATH, A SHOWER  
OR A SWIMMING POOL.  
WARNING – THIS HEATER MUST NOT BE LOCATED  
IMMEDIATELY BELOW A FIXED SOCKET OUTLET.  
DO NOT USE THE HEATER UNTIL IT IS WALL  
MOUNTED CORRECTLY.  
This heater must be used on an A.C.~ supply only and the  
voltage marked on the heater must correspond to the  
supply voltage.  
The heater carries a warning 'Do Not Cover' to alert  
the user to the risk of overheating that exists if the  
heater is accidentally covered.  
To comply with the I.E.E. Wiring Regulations, the appliance  
must be earthed; the supply circuit must be adequate for the  
input of the appliance, and the circuit protected by a suitable  
13A fuse. A suitable termination to the fixed wiring of the  
premises must be provided adjacent to the final position of the  
appliance. In this instance, such a termination can be a double-  
pole switch with a contact separation of at least 3mm in all  
poles.  
NEVER cover or obstruct in any way the air inlet slots  
at the front of the heater or the heat outlet slots in the  
base of the heater.  
Keep combustible materials such as drapes and other  
furnishings clear from the front of the heater. Do not  
use heater to dry your laundry.  
This appliance is not intended for use by children or  
other persons without assistance or supervision if  
their physical, sensory or mental capabilities prevent  
them from using it safely. Children should be  
supervised to ensure that they do not play with the  
appliance.  
The heater must not be located immediately below a fixed  
socket-outlet.  
Electrical  
If young children, the aged, or infirm are likely to be  
left in the vicinity of the heater, we advise that  
adequate precautions should be taken. We  
recommend that a guard be fitted to ensure contact  
with the heater is avoided and objects cannot be  
inserted into the product.  
WARNING : THIS APPLIANCE MUST BE EARTHED.  
After ensuring the electricity supply is not live, electrical  
connections can be made, either to an adjacent double-pole  
switch having a contact separation of at least 3mm in all poles  
or to a plug-top for use in a standard 13A socket.  
WARNING: In order to avoid  
a
hazard due to  
inadvertent resetting of the thermal cut-out, this  
appliance must not be supplied through an external  
switching device, such as a timer, or connected to a  
circuit that is regularly switched on and off by the  
utility.Do not use where excessive dust or moisture is  
present.  
If the latter: Connect Green and Yellow wire to plug terminal  
marked E or  
Green or Green and Yellow. Connect Blue  
wire to plug terminal marked N or Black. Connect Brown wire  
to plug terminal marked L or Red.  
Refit cover, first hooking top over the back of the unit and then  
securing the bottom by refitting the two screws under the  
bottom edge. The appliance is now ready for use and the  
electricity supply can be reinstated.  
For further information, please contact our guard  
supplier direct on Tel. No. 01603 667957, or in the  
case of difficulty or for further advice contact the  
Customer Helpline.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Cleaning  
WARNING :  
BEFORE UNDERTAKING ANY MAINTENANCE OR  
CLEANING WORK ON THE APPLIANCE, IMMEDIATELY  
DISCONNECT THE ELECTRICITY SUPPLY EITHER BY  
SWITCHING OFF AT THE ADJACENT DOUBLE POLE  
SWITCH OR BY REMOVING THE PLUG FROM THE  
SOCKET.  
Filter  
Retaining  
Wires  
The outside of the appliance should be wiped over with a soft  
damp cloth and then dried. Do not use detergents or abrasives.  
The filter should be cleaned by gently passing the soft brush  
attachment of a vacuum cleaner over the front grille.  
Mesh  
Filter  
Service and Repair  
Air Inlet  
Grille  
THE INTERNAL CLEANING AND MAINTENANCE WORK  
SHOULD ONLY BE UNDERTAKEN BY COMPETENT  
PERSONS WITH EXPERIENCE OF REPAIRING DOMESTIC  
ELECTRICAL APPLIANCES AND IN FULL KNOWLEDGE OF  
THE POSSIBLE HAZARDS INVOLVED.  
To ensure the appliance operates efficiently, the following  
maintenance should be undertaken periodically. The cover  
should be removed and refitted as detailed under ‘Procedure’.  
Fig. 5  
Fan Blades : These should be cleaned by using the soft  
brush attachment of a vacuum cleaner. Care should be  
taken not to damage the blades.  
Filter : The filter can be removed completely for cleaning,  
but generally provided this is cleaned frequently as  
detailed above, this should not be necessary. Where  
removal of filter is required for cleaning, the filter retaining  
wires can be removed, allowing the mesh and the filter to  
be taken out (see Fig. 5).  
General : With the cover removed, opportunity should be  
taken to remove any accumulations of dust from within the  
unit.  
Bearings : Fan and motor bearings should be given one  
or two (not more) drops of low viscosity oil (e.g. sewing  
machine oil) approximately every 12 months.  
Recycling  
For electrical products sold within the European Community.  
At the end of the electrical products useful life  
it should not be disposed of with household  
waste. Please recycle where facilities exist.  
Check with your Local Authority or retailer for  
recycling advice in your country.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
After Sales Service  
Your product is guaranteed for one year from the date of  
purchase.  
Within this period, we undertake to repair or exchange this  
product free of charge (excluding element  
&
subject to  
availability) provided it has been installed and operated in  
accordance with these instructions.  
Your rights under this guarantee are additional to your statutory  
rights, which in turn are not affected by this guarantee.  
Should you require after sales service you should contact our  
customer services help desk on 0845 600 5111. It would assist  
us if you can quote the model number, series, date of purchase,  
and nature of the fault at the time of your call. The customer  
services help desk will also be able to advise you should you  
need to purchase any spares.  
Please do not return a faulty product to us in the first instance  
as this may result in loss or damage and delay in providing you  
with a satisfactory service.  
Please retain your receipt as proof of purchase.  
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility  
(EMC) EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336  
Glen Dimplex UK Limited  
Millbrook House  
Grange Drive  
Hedge End  
Southampton  
UK customer help line 8.00AM – 5.00PM Mon-Fri; 8.30AM-1.00PM Sat (Autumn-Winter only)  
Customer Services:  
Republic of Ireland  
Tel.  
Fax.  
0845 600 5111  
01489 773053  
Tel. 01 8424833  
Hampshire. SO30 2DF  
[c] Glen Dimplex UK Limited  
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cisco Systems Network Router 5 User Manual
Continental Outdoor Fireplace CBI 360 P User Manual
Continental Platinum Microwave Oven CP41119 User Manual
Delta Electronics Power Supply SILM418 User Manual
Dynex Flat Panel Television DX LCD22 09 User Manual
Electro Voice Microphone 633 User Manual
Electro Voice Speaker DL12X User Manual
Everpure Water System EV939000 User Manual
Extron electronic Stereo Amplifier MPA 152 PLUS User Manual
Fellowes Paper Shredder 380 2 User Manual