Dimplex Electric Heater CAL075 User Manual

Installation and Operating Instructions  
Calidou Electronic Panel Radiator  
Models:  
CAL075 / CAL100 / CAL150 / CAL200  
Dimensions and Specification  
IP24  
Issue 5 November 2004  
Model  
Loading  
(kW)  
0.75  
1.0  
1.5  
Length (A) Height  
Depth  
(mm)  
142  
142  
142  
X
Y
Z
Weight  
(kg)  
17  
24  
33  
(mm)  
455  
(mm)  
604  
(mm) (mm) (mm)  
CAL075  
CAL100  
CAL150  
140  
300  
400  
87  
87  
226  
228  
234  
242  
621  
604  
870  
604  
CAL200  
2.0  
1202  
604  
142  
700  
227  
275  
47  
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE  
General  
IMPORTANT SAFETY ADVICE  
The Calidou radiator is designed to provide exceptional levels  
of comfort with a combination of radiant and convected heat  
in both domestic and commercial applications.  
When using electrical appliances, basic precautions should always  
be followed to reduce the risk of fire, electrical shock, and injury to  
persons, including the following:  
Wall Mounting / Installation  
The heater should be positioned observing the minimum clearances  
stated around the heater.  
(see also ‘Electrical’ section)  
The wall bracket supplied with the heater must be used  
WARNING THE SURFACES OF THIS HEATER CAN BE HOT  
Momentary contact with any part of the heater should not cause  
injury. However, aged or infirm persons or young children should not  
be left unsupervised in the vicinity of the heater unless a suitable  
guard is fitted  
1. Using a screwdriver, turn the latch in a clockwise direction to  
unlatch the bracket, then remove it from the appliance (see Fig.1)  
2. Mount the bracket on the wall using a minimum of 4 screws  
(max diameter 6mm) making sure that it is the correct way up and  
at the correct height. (see Fig.2)  
IMPORTANT – If this heater is installed in a room containing a bath or  
shower, it should be so installed that switches and other controls  
cannot be touched by a person using a bath or shower – to comply  
with this requirement see ‘Lock the Control Cover’ section on page 2.  
If you use this heater in conjunction with an external thermal control,  
a programme controller, a timer or any other device which switches  
the heat on automatically, observe all safety warnings AT ALL TIMES  
since a fire risk exists when the heater is accidentally covered or  
displaced  
3. Position the appliance on the bracket.  
4. Re-latch the bracket turning the latch anti-clockwise.  
The installation of this product should be carried out by an electrician  
or competent person and be in strict accordance with the current IEE  
Wiring Regulations and relevant Building Regulations  
This heater must not be mounted within 150mm of curtains and other  
combustible materials or 100mm from a shelf or overhang  
NEVER cover or obstruct in any way the heat outlet slots at the top of  
the heater or the air inlet slots at the base of the heater  
DO NOT cover the heater – Do not place material or garments on the  
heater or obstruct the air circulation around the heater  
Before connecting the heater check that the supply voltage is the  
same as that stated on the heater  
Fig.1  
The heater must be installed in accordance with these instructions  
The heater must be mounted using the wall bracket supplied. The  
heater should only be operated in the upright position  
The heater should be positioned in accordance to the clearances  
stated in these instructions  
Fig. 2  
Model  
CAL075  
CAL100  
CAL150  
CAL200  
A (mm  
140  
B (mm)  
228  
300  
234  
DO NOT locate this heater immediately beneath a fixed socket outlet  
400  
700  
242  
27  
Electrical  
The wires in the mains lead are coloured in accordance with the following code:  
If the wall is a light partition or crumbling, then supporting legs  
are also needed  
(Part No. CAL0001). The heater MUST be fitted to the wall as  
well as having the supporting legs  
GREEN & YELLOW  
BLUE  
BROWN  
EARTH  
NEUTRAL  
LIVE  
BLACK  
PILOT WIRE  
(See also ‘Pilot Wire Connection’)  
The heater is fitted with a length of flexible cable for connection to the fixed wiring of the  
premises through a suitable connection box positioned adjacent to the heater.  
The supply circuit to each heater must incorporate a double pole isolating switch having a  
contact separation of at least 3mm  
Pilot Wire Connection  
The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex  
programmers. If, however a programmer is not being used, the pilot wire should be isolated in  
accordance with the current IEE Wiring Regulations.  
IMPORTANT - Do NOT connect the BLACK pilot wire to earth  
Care should be taken with the installation of the pilot wire(s) as when switching to background  
(set back) they become energised at 240V although only at a current of 1mA.  
In every case a suitable means of isolation must be provided for the pilot wire and marked to  
indicate that two sources of supply may be present at the heater.  
1. Place the legs under the heater  
2. Position the hinges into the grooves in the air inlet  
3. Unscrew the jacks, until they reach the floor  
Where pilot wires are installed separately from the heater final sub-circuit they should be  
protected, double insulated and carry their own integral earth continuity conductor.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cooper Lighting Marine Safety Devices ELPS502 User Manual
Craftsman Snow Blower 53688644 User Manual
Craftsman Snow Blower 486248381 User Manual
Delta Electronics Power Supply Series V48SB User Manual
Dual Stereo Amplifier XPR User Manual
EVGA Computer Hardware 122 YW E173 User Manual
Fisher Paykel Ventilation Hood HC60PCIX2 User Manual
Frigidaire Dishwasher 154768601 User Manual
Garland Oven UIR36 User Manual
GE Monogram Refrigerator Side by Side Refrigerators User Manual