Digital Media Switch 900TL User Manual

DECmau 900TL  
INSTALLATION  
LKG–8137-93I  
DECmau 900TL  
DEChub ONE MAU 900TL  
PK–02580–IL  
The DECmau 900TL is a Token Ring Multistation Access Unit (MAU). As a member  
of Digital’s Token Ring product family, it operates in a DEChub 900 MultiSwitch, or a  
single-slot hub (DEChub ONE MAU 900TL). The MAU connects up to eight stations  
using 100-ohm shielded or unshielded cable with RJ45 connectors, and 150-ohm  
IBMType1datacableusinganimpedencematchingtransformercable. Itoperates  
at 4 or 16 Mb/s and incorporates speed detection. The MAU can also be managed  
by optional HUBwatch management software.  
EK–DTMAU–IN. A01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Front Panel  
1 ) Power LED. Lights when the MAU has power.  
1
2
2 ) Module OK LED. Lights when the MAU passes its  
self-test. If the MAU fails its self-test, the OK LED is  
off.  
3
4
3 ) Ring A/B LEDs. In a hub, either the A LED or the B  
LED is on to show the ring. In a standalone MAU,  
both Ring LEDs are always off.  
5
4 ) Speed LEDs. Either the 16 LED or the 4 LED is on  
to show the ring speed.  
5 ) Eight Lobe LEDs. Lights when a station has access  
to the network.  
6 ) Eight Lobe Connectors. Connects a station to the  
network. The MAU connects up to eight stations with  
shielded or unshielded 100-ohm cable, and 150-ohm  
IBM Type 1 data cable using an impedence matching  
transformer cable (Digital part number BN26T-03).  
7 ) Reset Switch. Resets the MAU to factory defaults.  
To reset: while turning on the power, press the reset  
switch with a pen or screwdriver.  
6
Notes:  
The DECmau 900TL has speed detect, which  
ensures the integrity of the network. At startup, a  
MAU determines the ring speed based on the  
speed settings of the majority of the stations on the  
ring and the Ring Out port. In a hub, the MAU then  
connects to the appropriate ring in the hub. After  
startup, speed detect prevents stations with the  
wrong speed setting from connecting to the net-  
work.  
K–02586–IL  
7
Network management can override any of the  
MAU’s factory default settings.  
LKG-8145-93I  
DECmau 900TL  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rear Panel of DEChub ONE MAU 900TL  
Note:  
The rear panel shown here is used only when the MAU  
is in a single-slot hub configuration.  
1
2
1 ) Ring In LED. Lights with a Ring In connection.  
2 ) Ring Out LED. Lights with a Ring Out connection.  
3) PowerConnector. Provides power connection for the  
MAU.  
3
4 ) Ring In Connector. Connects Ring In to the Ring  
Out connector of a MAU or repeater.  
5 ) Ring In Autowrap Switch. Determines whether the  
MAU automatically loops back when it detects a  
disconnected link on Ring In. If the Ring In port  
connects to a device with Digital’s Autowrap, set the  
switch to 1 to enable Autowrap. If the Ring In port  
connects to a device without Digital’s Autowrap, set  
the switch to 0 to disable Autowrap.  
4
5
6
7
6 ) Ring Out Connector. Connects Ring Out to the Ring  
In connector of a MAU or repeater.  
7 ) Ring Out Autowrap Switch. Determines whether the  
MAU automatically loops back when it detects a  
disconnected link on Ring Out. If the Ring Out port  
connects to a device with Digital’s Autowrap, set the  
switch to 1 to enable Autowrap. If the Ring Out port  
connects to a device without Digital’s Autowrap, set  
the switch to 0 to disable Autowrap.  
8
8 ) Not used. Reserved for out-of-band network  
management.  
LKG-8146-93I  
4
DECmau 900TL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a MAU in a DEChub 900 MultiSwitch  
WhenyouinstallaMAUinaDEChub900MultiSwitch, youdonothavetoturnoffthehubpower.  
1
Remove the single-slot hub (if necessary).  
If you want to install a DEChub ONE MAU 900TL in a hub,  
you need to remove the single-slot hub.  
a. Loosen the screw on the single-slot  
hub until it disengages.  
b. With one hand holding the front of  
the MAU, and your other hand  
holding the single-slot hub,  
carefully pull the two units apart.  
a. Align the MAU’s 48-pin connector  
2
Install the MAU in the hub.  
with any available 48-pin slot on the  
The release lever is  
lifted and clicks  
back into place  
as the module  
is seated.  
hub.  
b. Place the MAU’s bottom mounting  
tab into the mounting slot on the hub.  
c. RocktheMAUintoplace. Youheara  
‘‘click” when the MAU is seated.  
Mounting  
tab  
LKG–8139-93I  
DECmau 900TL  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a MAU in a DEChub 900 MultiSwitch (continued)  
Verify power.  
3
With power on in the hub, verify that the  
Power and Module OK LEDs are on.  
LKG–8141-93I  
Connect station cables.  
4
Connect station cables to any  
available lobe connector on the  
MAU. For 150-ohm applications,  
you also need an impedence  
matching transformer cable  
(Digital part number BN26T-03).  
Module installation for  
a
DEChub 900 MultiSwitch  
is complete.  
PK–02570–IL  
LKG–8140-93I  
6
DECmau 900TL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a DEChub ONE MAU 900TL  
Mount MAU (optional).  
1
You can place the MAU on a table, mount it on a wall, or mount it in a standard 19-inch rack  
using a shelf assembly, Digital part number H9544-MS.  
For a wall mounting, position two screws 19.7 centimeters (7.75 inches) apart on the wall. Turn  
screws until tight and then back off two turns. Hang the MAU using the keyholes.  
2
Set Autowrap switches.  
a. Set the Ring In and the Ring Out Autowrap  
switches to 1 or 0.  
b. Set the switch to 1 to enable Autowrap  
when the Ring In or Ring Out port  
connects to a device with Digital’s Auto  
wrap, there is only one MAU in the  
network, or the port is not connected to  
the network. Otherwise, set the switch to  
0 to disable Autowrap.  
To  
power  
LKG–8142-93I  
supply  
3
Connect power supply.  
a. Connect the power supply cable to  
the power connector.  
b. Plug the power supply into a wall  
outlet.  
DECmau 900TL  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a DEChub ONE MAU 900TL (continued)  
Connect station cables.  
4
Connect station cables to any available  
lobe connector on the MAU. For  
150-ohm applications, you also need an  
impedence matching transformer cable  
(Digital part number BN26T-03).  
5
Install a MAU to adjacent MAUs or repeaters.  
If a MAU is being added to an existing  
network, connect Ring In  
Out connector of a MAU or repeater, and  
connect Ring Out to the Ring In  
to the Ring  
connector of a MAU or repeater.  
Check LEDs.  
6
With power on, verify that the Power and  
Module OK LEDs are on.  
Module installation for  
DEChub ONE MAU 900TL  
is complete.  
a
LKG–8143-93I  
8
DECmau 900TL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing a MAU from a DEChub 900 MultiSwitch  
1
Disconnect the station connector cables from the MAU.  
Remove the MAU from the hub.  
2
a. Lift up the Release lever on the  
hub.  
Note:  
When you remove a MAU from the  
hub, do not turn off the hub power.  
b. Pivot the MAU back on its  
bottom mounting tab until it  
disengages from the hub.  
The release lever is  
lifted and clicks  
back into place  
as the module  
is removed.  
Mounting  
tab  
LKG–8144-93I  
DECmau 900TL  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
LED Summary  
The LEDs indicate status by being on, off, and flashing. Flashing LEDs indicate special situations.  
There are two flashing patterns and a scroll pattern. When an LED indicates a continuous single-flash  
pattern, network management has disabled the port. A continuous double-flash pattern indicates the  
wrong speed. In a scroll pattern, the LEDs turn on and off in a set order.  
1
LED  
Off  
On  
Flashing  
Power  
No Power  
Power OK  
Self-test OK  
Module OK Self-test failed  
or not operating  
4/16 Mb/s  
No activity  
Valid speed or  
management set  
speed  
Lobe  
Inactive  
Connected to network Continuous single flash: network  
management disabled port.  
Continuous double flash: wrong speed.  
Hub MAU ONLY:  
Ring A/B  
Not connected  
Connected to Ring A  
or Ring B  
Continuous single flash: network  
management disabled port.  
A and B alternately flash: MAU needs an  
upgrade or an upgrade is in progress.  
DEChub ONE ONLY:  
Ring In/  
Ring Out  
Inactive or  
wire fault  
Connected to network Continuous single flash: network  
management disabled port.  
Continuous double flash: wrong speed.  
1
Scroll: During power-up self-tests, all LEDs, except the Power LED, indicate a scrolling  
pattern.  
10  
DECmau 900TL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cabling  
Table 1 lists the Token Ring industry guideline for the maximum lobe length of shielded twisted-pair  
(STP) and unshielded twisted-pair (UTP) cable.  
Table 1 Industry Lobe Length Guideline  
UTP  
STP  
Speed  
4 Mb/s  
16 Mb/s  
Level 3  
Level 5  
100 m (327 ft)  
65 m (213 ft)  
100 m (327 ft)  
100 m (327 ft)  
100 m (327 ft)  
100 m (327 ft)  
Lobe lengths for Digital’s MAUs exceed the industry guideline. Specifically, lobe lengths can be longer  
than the industry guideline for STP cable and UTP level 5 cable at 4 Mb/s. See Table 2, Digital Lobe  
Length Guideline, for the maximum lobe lengths for Digital’s MAUs. Also refer to either “DEChub 900  
MultiSwitch Configuration or DEChub ONE Configurations” below for more configuration information.  
1
Table 2 Digital Lobe Length Guideline  
UTP  
STP  
Speed  
4 Mb/s  
16 Mb/s  
Level 3  
Level 5  
100 m (327 ft)  
65 m (213 ft)  
200 m (655 ft)  
100 m (327 ft)  
376 m (1235 ft)  
173 m (569 ft)  
1
All distances include patch cables and hub connections.  
Digital recommends that you keep lobe lengths within the maximums found in the industry guideline  
whenever possible. This allows for future network expansion and upgrade. When current needs  
dictate the longer lobe lengths, you can increase lobe lengths up to the maximums in Digital’sguideline  
without any negative effect on the network.  
DEChub 900 MultiSwitch Configuration  
Multiple Hubs  
A repeater is needed in each hub to connect hubs in a multiple hub network. Refer to the  
appropriate Token Ring repeater manual for specific information.  
DEChub ONE Configurations  
Unshielded Twisted-Pair Cable Configurations:  
Multiple MAUs in One Wiring Closet at 16 Mb/s  
At 16 Mb/s, a maximum of five MAUs can be in one wiring closet without affecting maximum lobe  
length. Subtract 10 meters from the lobe lengths in Table 2 for each additional MAU above five in a  
wiring closet.  
Multiple Wiring Closets  
Digital recommends that you use repeaters to segment the ring in a network with multiple wiring  
closets. In some situations, only one, or no repeaters, are required. Refer to the appropriate  
Token Ring repeater manual for specific information.  
DECmau 900TL  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cabling (continued)  
Digital recommends that you use repeaters to segment the ring in a network with multiple wiring  
closets. In some situations, only one, or no repeaters, are required. Refer to the appropriate Token  
Ring repeater manual for specific information.  
When distances exceed the lobe lengths in Table 2, or if the MAU does not have Digital’s Autowrap  
functionality, two repeaters are required.  
When a MAU has Autowrap enabled, only one repeater is required per wiring closet if the distance  
between the wiring closets does not exceed the distances shown in Table 2.  
With UTP level 5 cable at 4 Mb/s, no repeaters are required with multiple wiring closets if the total cable  
budget is within the distances shown in Table 3.  
For UTP level 3 cable at 4 Mb/s, divide all distances in Table 3 by 1.3.  
1
Table 3 Total Cable Budget for UTP Level 5 Cable at 4 Mb/s  
W i r i n g C l o s e t s  
MAUs  
0
1
2
3
4
5
6
1
2
3
4
5
210 m (689 ft) 206 m (675 ft)  
192 m (630 ft) 189 m (620 ft) 185 m (607 ft)  
175 m (574 ft) 171 m (561 ft) 168 m (551 ft) 164 m (538 ft)  
157 m (515 ft) 154 m (505 ft) 150 m (492 ft) 147 m (482 ft) 143 m (469 ft)  
140 m (459 ft) 136 m (446 ft) 133 m (436 ft) 129 m (423 ft) 126 m (413 ft) 122 m (400 ft)  
122 m (400 ft) 119 m (390 ft) 115. m (377 ft) 112 m (367 ft) 108 m (354 ft) 105 m (344 ft) 101 m (331 ft)  
6
1
All distances include patch cables.  
Total cable budget = maximum lobe length + adjusted ring length  
Adjusted ring length = total trunk length – shortest trunk length  
Shielded Twisted-Pair Cable Configuration:  
Digital supports industry standards for shielded twisted-pair (STP) cable. Refer to theIBM Token Ring  
Network Introduction and Planning Guide for specific information on STP cable.  
Cable Connector Specifications  
Table 4 lists the signal names of each pin associated with the Ring In, Ring Out, and Lobe connectors.  
The shaded area in the table indicates signals used only by Token Ring.  
Table 4 MAU Connector Signal Names  
Connector  
Name  
Pins  
4
1
2
3
5
6
7
8
Ring In  
RS422 RX+ RS422 RX– Transmit– Receive+  
Receive–  
Transmit–  
Transmit–  
Transmit+  
Receive+  
Receive+  
RS422 TX– RS422 TX+  
Ring Out  
not used  
not used  
not used  
not used  
Receive–  
Receive–  
Transmit+  
Transmit+  
not used  
not used  
not used  
Lobe  
not used  
12  
DECmau 900TL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem Solving  
If ...  
Then ...  
Do This ...  
DEChub 900 MultiSwitch and DEChub ONE  
Power LED is off.  
MAU does not have power.  
MAU failed self-test.  
Verify that outlet has power.  
Check power connection to MAU.  
Replace power supply.  
Replace MAU.  
Module OK LED is off.  
Replace MAU.  
Ring A and B LEDs alternately MAU needs an upgrade  
If you have network management,  
do a downline load;  
flash.  
or an upgrade is in progress.  
otherwise, replace MAU.  
Wait for upgrade to complete.  
Start up at least one station.  
Both Speed LEDs are off.  
No activity is on the network.  
Lobe LED is off after station  
completes self-test  
Station cannot access  
network.  
Check lobe cabling for crossover  
between transmit and receive  
wires. All cables, including patch  
cables, must be straight through.  
Lobe LED indicates a  
continuous single flash  
pattern.  
Network management  
disconnected station from the network management commands  
network. or the MAU’s Reset switch.  
To change setting, you can use  
Lobe LED indicates a  
continuous double flash  
pattern.  
MAU and station have different Change the speed setting of the  
speed settings. station.  
DECmau 900TL  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem Solving (continued)  
If ...  
Then ...  
Do This ...  
DEChub 900 MultiSwitch ONLY  
Lobe, Ring In, Ring Out,  
Ring A/B LEDs flash together. disabled MAU.  
Network management has  
To change settings, you can use  
network management commands  
or the MAU’s Reset switch.  
MAU does not connect to  
hub.  
Network management will not Check speed and hub  
connect MAU to hub.  
settings for incorrect network  
management overrides.  
MAU does not work  
in DEChub 90.  
DEChub 90 only supports  
Ethernet networks.  
A DEChub 900 MultiSwitch  
supports Token Ring networks.  
DEChub ONE ONLY  
Ring In or Ring Out LED  
indicates a continuous  
single flash pattern.  
Network management  
disconnected the MAU’s  
RI or RO port.  
To change setting, you can use  
network management commands  
or the MAU’s Reset switch.  
Ring In or Ring Out LED  
indicates a continuous  
double flash pattern.  
MAU and ring have different  
speed settings.  
Change the speed setting of the  
stations or the ring.  
Lobe, Ring In and Ring Out  
LEDs flash together.  
Network management has  
disabled MAU.  
To change settings, you can use  
network management commands  
or the MAU’s Reset switch.  
Vendor’s MAU or repeater  
causes loopback on ring.  
Vendor’s unit is incompatible  
with Digital’s Autowrap.  
Set Autowrap switches on the  
DECmau or DECrepeater adjacent  
to the vendor’s unit to 0.  
Network crashes when a MAU Vendor’s unit does not have  
Set Autowrap switches on the  
DECmau or DECrepeater adjacent  
to the failed unit to 1.  
or repeater fails.  
Digital’s Autowrap.  
14  
DECmau 900TL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Specifications  
Product Specification  
In a Hub  
DEChub ONE  
Size  
27.3 x 11.2 x 3.2 cm  
(10.8 x 4.4 x 1.2 inches)  
27.3 x 17.0 x 3.2 cm  
(10.75 x 6.7 x 1.25 inches)  
Weight  
.82kg (1.5 lb)  
1.09kg (2.0 lb)  
Operating temperature  
Relative humidity  
Altitude  
5° C to 50° C (41° F to 122° F)  
10% to 95% non-condensing  
Sea level to 4800 m (16,000 ft)  
Hub provides  
5° C to 50° C (41° F to 122° F)  
10% to 95% non-condensing  
Sea level to 4800 m (16,000 ft)  
Power Supply  
Provided by:  
H7082–AB  
Input Power  
1.0 A @ +5.1 Vdc  
RJ-45  
1.0 A @ +5.1 Vdc  
RJ-45  
Connectors  
Agency certification  
UL, TÜV, CSA, FCC, VDE  
No acoustic noise  
UL, TÜV, CSA, FCC, VDE  
No acoustic noise  
Acoustics: Preliminary  
declared values per ISO  
9296 and ISO 7779  
Schallemissionswerte:  
Vorläuge Werteangaben  
nach ISO 9296 und ISO  
7779/DIN EN27779  
keine meßbaren Schallemissionen keine meßbaren Schallemissionen  
Associated Document  
DEChub 900 MultiSwitch  
Owner’s Manual  
This manual provides overview, installation, and problem-  
solving information for the DEChub 900 MultiSwitch.  
DECmau 900TL  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Conair Crib Toy BE52LED User Manual
Conair Hair Clippers IB 9 344 User Manual
Cooper Lighting Landscape Lighting MEM17MWW2SXSNBK User Manual
Cortelco Cordless Telephone CP4400 User Manual
Delta Electronics Power Supply S24SA User Manual
Earthquake Sound Stereo Amplifier PH1000W 2 User Manual
Eaton Electrical Marine Radio IB 29C892B User Manual
Elation Professional Indoor Furnishings Rayzor Q7 User Manual
Fisher Price Riding Toy K6670 User Manual
Fusion Car Stereo System CA ML600 User Manual