YELLOW FLAME DESIGN
UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
(Manually-Controlled Models Also Designed Certified as Vented Decorative Appliance)
This appliance may be installed in an aftermarket* manufactured (mobile) home, where
not prohibited by state or local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
OWNER’S OPERATION AND INSTALLATION MANUAL
24"
18", 24", and
30" Variable
Manually-
Controlled
Models
Thermostatically-
Controlled Model
CGD3924PT
CGD3018P
CGD3924P
CGD3930P
®
WARNING:Improperinstallation,adjust-
ment,alteration,service,ormaintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For
assistance or additional information
consult a qualified installer, service
agency, or the gas supplier.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your build-
ing.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
WARNING: This gas log set is for instal-
lation in a masonry solid fuel burning
fireplace or a U.L. listed manufactured
solid fuel burning fireplace.
WARNING: This is an unvented gas-
fired heater. It uses air (oxygen) from
the room in which it is installed. Provi-
sionsforadequatecombustionandven-
tilation air must be provided. Refer to
Air for Combustion and Ventilation sec-
tion in this manual.
• If you cannot reach your gas sup-
plier, call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
Save this manual for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNINGS Continued
WARNING: Any change to this heater or its controls can be dangerous.
1. This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
2. Donotplacepropane(LP)supplytank(s)insideanystructure.Locatepropane(LP)supply
tank(s) outdoors.
SAFETY
INFORMATION
Continued
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your building
• immediatelycallyourgassupplierfromaneighbor’sphone. Followthegassupplier’s
instructions
• if you cannot reach your gas supplier, call the fire department
4. This heater shall not be installed in a bedroom or bathroom.
5. Never install the heater
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 36 inches
from the front, top, or sides of the heater
• in high traffic areas
• in windy or drafty areas
6. Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be
cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote
will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater
with flue damper closed.
7. Iffireplacehasglassdoors,neveroperatethisheaterwithglassdoorsclosed.Ifyouoperate
heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if
fireplaceopeninghasventsatthebottom,youmustopentheventsbeforeoperatingheater.
8. You must operate this heater with a fireplace screen in place. Make sure fireplace screen
is closed before running heater.
9. This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater
and call a qualified service person. Note: During initial operation, slight smoking could
occur due to log curing and heater burning manufacturing residues.
10. Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner
flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered
burner patterns can cause sooting.
11. Do not use a blower insert, heat exchanger insert or other accessory not approved for use
with this heater.
12. This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen
depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not
enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 8.
If heater keeps shutting off, see Troubleshooting, pages 25 through 28.
13. Do not run heater
• where flammable liquids or vapors are used or stored
• under dusty conditions
14. Do not use this heater to cook food or burn paper or other objects.
15. Never place any objects on the heater.
16. Heater base assembly becomes very hot when running heater. Keep children and adults
awayfromhotsurfacetoavoidburnsorclothingignition. Heaterwillremainhotforatime
after shut-down. Allow surface to cool before touching.
17. Carefully supervise young children when they are in the room with heater.
18. Do not use heater if any part has been exposed to or under water. Immediately call a
qualifiedservicetechniciantoinspecttheroomheaterandtoreplaceanypartofthecontrol
system and any gas control which has been under water.
19. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-
sized or larger).
20. Turn heater off and let cool before servicing. Only a qualified service person should
service and repair heater.
21. Operating heater above elevations of 4,500 feet could cause pilot outage.
3
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT
Crossover Log
Back Log
IDENTIFICATION
Front Log
Burner
Middle Log
Piezo
Ignitor
Control Knob
Base Grate
Figure 1 - Vent-Free Gas Log Heater
Install and use heater with care. Follow all local codes. In the absence of local
codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also
known as NFPA 54*.
LOCAL CODES
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note: Where listed vented decorative logs are required, thermostat operation is not
permitted.
1. Remove logs and heater base assembly from carton. Note: Do not pick up heater
base assembly by burners. This could damage heater. Always handle base
assembly by grate.
UNPACKING
2. Remove all protective packaging applied to logs and heater for shipment.
3. Check all items for any shipping damage. If damaged, promptly inform dealer
where you bought heater.
Operation
PRODUCT
FEATURES
This heater is clean burning. It requires no outside venting. There is no heat loss out a
ventorupachimney. Heatisgeneratedbyrealisticdancing, yellowflames. Thisheater
is designed for vent-free operation with flue damper closed. State and local codes in
some areas prohibit the use of vent-free heaters. You can operate heater as a vented
product by opening flue damper.
Safety Device
This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS).
The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts
off the heater if there is not enough fresh air.
Piezo Ignition System
This heater has a piezo ignitor. This system requires no matches, batteries, or other
4
sources to light heater.
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR FOR
COMBUSTION
AND
WARNING
WARNING ICON
G
001
This heater shall not be installed in a confined space unless
provisions are provided for adequate combustion and ventilation
air. Read the following instructions to insure proper fresh air for
this and other fuel-burning appliances in your home.
VENTILATION
Today’s homes are built more energy efficient than ever. New materials, increased
insulation, and new construction methods help reduce heat loss in homes. Home
owners weather strip and caulk around windows and doors to keep the cold air out
and the warm air in. During heating months, home owners want their homes as
airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe.
Fresh air must enter your home. All fuel-burning appliances need fresh air for
proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from
the house to operate. You must provide adequate fresh air for these appliances.
This will insure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1,
Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications:
1. Unusually Tight Contruction; 2. Unconfined Space; 3. Confined Space.
The information on pages 5 through 7 will help you classify your space and provide
adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for
combustion and ventilation. However, in buildings of unusually tight construction,
you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the outside atmosphere have a continu-
ous water vapor retarder with a rating of one perm or less with open-
ings gasketed or sealed and
b. weather stripping has been added on openable windows and doors and
c. caulking or sealants are applied to areas such as joints around window
and door frames, between sole plates and floors, between wall-ceiling
joints, between wall panels, at penetrations for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide addi-
tional fresh air. See Ventilation Air From Outdoors, page 7.
If your home does not meet all of the three criteria above, proceed to page 6.
Unconfined Space
The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines uncon-
fined space as having a minimum air volume of 50 cubic feet (127 cubic cm) for
each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals
length x width x height of space). Include adjoining rooms only if there are
doorless passageways or ventilation grills between the rooms.
Confined Space
The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines confined
space as having an air volume of less than 50 cubic feet (127 cubic cm) for each
1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length
x width x height of space). Include adjoining rooms only if there are doorless
passageways or ventilation grills between the rooms.
Continued
5
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
DETERMINING AIR FLOW FOR HEATER LOCATION
AIR FOR
COMBUSTION
AND
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with
doorless passageways or ventilation grills between the rooms.
VENTILATION
1. Determine the volume of the space (length x width x height).
Continued
Length x Width x Height =
___________________
cu. ft. (volume of space)
Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) =
2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the
volume of these rooms to the total volume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space
can support.
____________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr
the space can support)
Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum
Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free heater
Gas water heater*
Gas furnace
Vented gas heater
Gas fireplace logs
Other gas appliances*
Total
___________________ Btu/Hr
___________________ Btu/Hr
___________________ Btu/Hr
___________________ Btu/Hr
___________________ Btu/Hr
+ ___________________ Btu/Hr
= ___________________ Btu/Hr
Example: Gas water heater
Vent-free heater
Total
40,000
39,000
79,000
Btu/Hr
Btu/Hr
Btu/Hr
+
=
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the
outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr
used.
_________________ Btu/Hr (maximum the space can support)
_________________ Btu/Hr (actual amount of Btu/Hr used)
Example: 51,200 Btu/Hr (maximum the space can support)
79,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more
than the maximum Btu/Hr the space can support. You must provide additional fresh air.
Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides
an unconfined space, remove door to adjoining room or add ventilation grills between
rooms. See Ventilation Air From Inside Building, page 7.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7.
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space
is an unconfined space. You will need no additional fresh air ventilation.
6
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR FOR
COMBUSTION
AND
WARNING
If the area in which the heater may be operated is smaller than
that defined as an unconfined space, provide adequate combus-
tion and ventilation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3.
VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an
adjoining unconfined space, you must provide two permanent openings: one within 12" of the
ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1
and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2).
Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion
and Ventilation for required size of ventilation grills or ducts.
WARNING
Rework worksheet, adding the space of the adjoining unconfined
space. The combined spaces must have enough fresh air to supply all
appliances in both spaces.
12"
Ventilation
Ventilation Grills
Into Adjoining Room,
Option 2
Grills
Into Adjoining
Room,
Or
Remove
Door into
Adjoining
Room,
Option
3
Option 1
12"
Figure 2 - Ventilation Air from Inside Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect
these items directly to the outdoors or spaces open to the outdoors. These spaces include
attics and crawl spaces.
IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-
controlled power vent. Heated air entering the attic will activate the power vent.
Ventilated
Outlet
Attic
Air
Outlet
Air
To Attic
To
Crawl
Space
Inlet
Air
Ventilated
Inlet Air
Crawl Space
Figure 3 - Ventilation Air from Outdoors
7
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING
NOTICE
A qualified service person must install heater. Follow all local codes.
NOTICE
State or local codes may only allow operation of this appliance in a
vented configuration. Check your state or local codes.
WARNING
Before installing in a solid fuel burning fireplace, the chimney flue
and firebox must be cleaned of soot, creosote, ashes and loose paint
by a qualified chimney cleaner. Creosote will ignite if highly heated.
Inspect chimney flue for damage. If damaged, operate heater with
flue damper closed.
WARNING
Sealanyfreshairventsorashclean-outdoorslocatedonfloororwall
of fireplace. If not, drafting may cause pilot outage or sooting. Use a
heat-resistant sealant. Do not seal chimney flue damper.
WARNING
Never install the heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects
are less than 36 inches from the front, top, or sides of the heater
• in high traffic areas
• in windy or drafty areas
CAUTION
This heater creates warm air currents. These currents move heat
to wall surfaces next to heater. Installing heater next to vinyl or
cloth wall coverings or operating heater where impurities in the air
(such as tobacco smoke) exist, may discolor walls.
IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial,
installing heater in rooms without enough ventilation air may cause mildew to form
from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.
CHECK GAS TYPE
Use only propane gas. If your gas supply is not propane, do not install heater. Call
dealer where you bought heater for proper type heater.
8
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION AND CLEARANCES (Vent-Free Operation Only)
INSTALLING
Continued
WARNING
Maintain the minimum clearances. If you can, provide greater clear-
ances from floor, ceiling, and adjoining wall.
MINIMUM FIREPLACE CLEARANCE
TO COMBUSTIBLE MATERIALS
Log Size
Side Wall
Ceiling
18", 24", 30"
16"
42"
LOG SIZING REQUIREMENTS
Log
Size
18"
24"
30"
Minimum Firebox Size
Height
17"
17"
17"
Depth
14"
14"
Front Width
20"
26"
32"
14"
Carefully follow the instructions below. This will ensure safe installation into a
masonry or U.L. listed manufactured fireplace.
Minimum Wall and Ceiling Clearances (see Figure 4)
A. Clearances from the side of the fireplace opening to any combustible wall
should not be less than 16 inches.
B. Clearances from the top of the fireplace opening to the ceiling should not be
less than 42 inches.
42"
16"
Left and Right
Sides
Figure 4 - Minimum Clearance to Wall and Ceiling
Continued
9
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING
NOTICE
You may use this heater as a vented product. If so, you must
always run heater with chimney flue damper open. If running
heater with damper open, non-combustible material above fire-
place opening is not needed. Go to Installing Damper Clamp
Accessory for Vented Operation, page 13.
Continued
Minimum Non Combustible Material Clearances
If Not Using Mantel
Note: If using a mantel, go to page 11. If not using a mantel, follow the informa-
tion on this page.
You must have non combustible material(s) above the fireplace opening. Non
combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch
thick. With sheet metal, you must have non combustible material behind it. Non
combustible material must extend at least 8" up (for all models). If non combus-
tible material is less than 12", you must install the fireplace hood accessory (24"
and 30" models only). See chart below and Figure 5 for minimum clearances.
IMPORTANT: If you cannot meet these minimum clearances, you must operate
heater with chimney flue damper open. Go to Installing Damper Clamp Accessory
for Vented Operation, page 13.
Non-Combustible
Material Distance (A)
Requirements for
Safe Installation
12" or more
Non combustible material okay.
Between 8" and 12"
24" or 30" Models: Install fireplace hood acessory
(GA6050 or GA6052, see Accessories, page 33).
18" Model: Non combustible material okay.
Less than 8"
Non combustible material must be extended to at
least 8". See Between 8" and 12", above. If you
cannot extend material, you must operate heater
with flue damper open.
Heat Resistant
Material
(A)
Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace
10
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
Minimum Non Combustible Material Clearances
INSTALLING
If Using Mantel
Continued
You must have non combustible material(s) above the fireplace opening. Non
combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch
thick. With sheet metal, you must have non combustible material behind it. Non
combustible material must extend at least 8 inches up (for all models). If non
combustible material is less than 12", you must install the fireplace hood acces-
sory (24" and 30" models only). Even if non combustible material is more than
12", you may need the hood accessory to deflect heat away from your mantel
shelf. See chart below and Figures 6 and 7 for minimum clearances.
IMPORTANT: If you cannot meet these minimum clearances, you must operate
heater with chimney flue damper open. Go to Installing Damper Clamp Acces-
sory for Vented Operation, page 13.
Non-Combustible
Material Distance (A)
Requirements for
Safe Installation
12" or more
Non combustible material okay.
Between 8" and 12"
24" or 30" Models: Install fireplace hood acessory
(GA6050 or GA6052, see Accessories, page 33).
18" Model: Non combustable material okay.
Less than 8"
Non combustible material must be extended to at
least 8". See Between 8" and 12", above. If you
cannot extend material, you must operate heater
with flue damper open.
Mantel Clearances
If you meet minimum clearance between mantel shelf and top of fireplace open-
ing, a hood is not required (see Figure 6).
Mantel Shelf
10"
Underside of
Mantel Shelf
8"
6"
2 1/2"
All minimum
distances are
in inches
Minimum Non-
Combustible
(A)
Log Set
24"/30" Models
Material
12"
8"
20"
14"
241/2"
163/4"
271/2" 30"
181/2" 20"
18" Model
Top of Fireplace
Opening
Minimum Non-
Combustible
Material Height
Distances to
Underside of
Mantel
Figure 6 - Minimum Mantel Clearances Without Using Hood
If above minimum clearances are not met, you must have a hood. Follow
minimum clearances shown in Figure 7 when using hood.
11
Continued
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
Mantel Shelf
INSTALLING
12"
10"
8"
Underside of
Mantel Shelf
Continued
6"
2 1/2"
All minimum
distances are
in inches
Minimum Non-
Combustible
Material
Log Set
8"
Min.
12"
15"
18"
20"
18", 24", 30"
Models
Top of Fireplace
Opening
Hood
(GA6050, GA6052)
Distances to
Underside of
Mantel
Figure 7 - Minimum Mantel Clearances When Using Hood
If your installation does not meet the above minimum clearances, you must:
• operate the logs only with the flue damper open, OR
• raise the mantel to an acceptable height, OR
• remove the mantel.
Floor Clearances
A. If installing appliance on the floor level, you must maintain the minimum
distance of 14" to combustibles (see Figure 8).
Combustible
Material
14"
Min.
Non-Combustible Material
Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level
B. If combustible materials are less than 14" to the fireplace, you must install
appliance at least 5" above the combustible flooring (see Figure 9).
Hearth
Combustible
Material
5"
Min.
Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring
12
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING DAMPER CLAMP ACCESSORY FOR
VENTED OPERATION
Note: When used as a vented heater, appliance must be installed only in a solid-
fuel burning fireplace with a working flue and constructed of non combustible
material.
INSTALLING
Continued
If your heater is a manually controlled model, you may use this heater as a vented
product. There are three reasons for operating your heater in the vented mode.
1. The fireplace does not meet the clearance to combustibles requirements for
vent-free operation.
2. State or local codes do not permit vent-free operation.
3. You prefer vented operation.
Ifreasonsnumber1or2aboveapplytoyou, youmustpermanentlyopenchimneyflue
damper. Youmustinstallthedamperclampaccessory(toorder, seeAccessories,page
33). This will insure vented operation (see Figure 10). The damper clamp will keep
damper open. Installation instructions are included with clamp accessory.
See chart below for minimum permanent flue opening you must provide. Attach
damperclampsotheminimumpermanentflueopeningwillbemaintainedatalltimes.
Chimney
Height (ft.)
Minimum Permanent
Flue Opening (sq. ins.)
6' to 15'
15' to 30'
39 sq. inches
29 sq. inches
Area of Various Standard Round Flues
Diameter (ins.)
Area (sq. ins.)
5"
6"
7"
8"
20 sq. inches
29 sq. inches
39 sq. inches
51 sq. inches
Damper
Clamp
Damper
Damper
Clamp
Damper
Damper
Masonry Fireplace
Manufactured Fireplace
Figure 10 - Attaching Damper Clamp
13
Continued
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING HEATER BASE ASSEMBLY
INSTALLING
Continued
WARNING
You must secure this heater to fireplace floor. If not, heater will move
when you adjust controls. Moving heater may cause a gas leak.
WARNING
If installing in a sunken fireplace, special care is needed. You
must raise the fireplace floor to allow access to heater control
panel. This will insure adequate air flow and guard against soot-
ing. Raise fireplace floor with non-combustible material. Make
sure material is secure.
CAUTION
Do not pick up heater base assembly by the burner. This could
damage heater. Only handle base assembly by grates.
IMPORTANT: Make sure the heater burners are level. If heater is not level, heater
will not work properly. For thermostat models, avoid damage to thermostat bulb.
Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in
mounting bracket.
Installation Items Needed
• hardware package (provided with heater)
• approved flexible gas hose (not provided) (if allowed by local codes)
• sealant resistant to propane (propane/LP) gas, not provided
• electric drill with 3/16" drill bit
1. Apply pipe joint sealant lightly to male threads of the fitting to be threaded into
gas regulator. Connect approved flexible gas hose to gas regulator of heater
(see Figure 11).
IMPORTANT:Hold gas regulator with wrench when connecting flexible gas hose.
2. Locate masonary screws in hardware package.
3. Position heater base assembly in fireplace.
4. Mark screw locations through holes in mounting brackets (see Figure 12, page
15). If installing in a brick-bottom fireplace, mark screw locations in mortar
joint of bricks.
5. Remove heater base from fireplace.
6. Drill holes at marked locations using 3/16" drill bit.
7. Attach base assembly to fireplace floor using two masonry screws (in hardware
package) (see Figure 12, page 15).
8. Connect to gas supply. See Connecting To Gas Supply, page 15.
Heater Gas
Regulator
Fitting
Flexible Gas Hose
(if allowed by local codes)
Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator
14
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING
Masonry Screw
Continued
Mounting
Bracket
Figure 12 - Attaching Base Assembly to Fireplace Floor
CONNECTING TO GAS SUPPLY
NOTICE
A qualified service person must connect heater to gas supply.
Follow all local codes.
CAUTION
Never connect heater directly to the propane supply. This heater
requires an external regulator (not supplied). Install the external
regulator between the heater and propane supply.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
• external regulator (supplied by
installer, see page 16)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* AnA.G.A. design-certifiedmanualshutoffvalvewith1/8"NPTtapisanacceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See Accessories, page 33.
Continued
15
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
The installer must supply an external regulator. The external regulator will reduce
incoming gas pressure. You must reduce incoming gas pressure to between 11 and
14 inches of water. If you do not reduce incoming gas pressure, heater regulator
damage could occur. Install external regulator with the vent pointing down as
shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.
INSTALLING
Continued
Propane
Supply Tank
External
Regulator
Vent Pointing
Down
Figure 13 - External Regulator With Vent Pointing Down
CAUTION
Use only new, black iron or steel pipe. Internally-tinned copper
tubing may be used in certain areas. Check your local codes. Use
pipe of 1/2" diameter or greater to allow proper gas volume to
heater. If pipe is too small, undue loss of pressure will occur.
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream
from heater (see Figure 14, page 17).
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION
Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
Install sediment trap in supply line as shown in Figure 14, page 17. Locate sedi-
ment trap where it is within reach for cleaning. Locate sediment trap where trapped
matter is not likely to freeze. A sediment trap traps moisture and contaminants.
This keeps them from going into heater controls. If sediment trap is not installed or
is installed wrong, heater may not run properly.
16
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING
CAUTION
Continued
Avoid damage to regulator. Hold gas regulator with wrench when
connecting it to gas piping and/or fittings.
A.G.A. Design-Certified
Manual Shutoff Valve
With 1/8" NPT Tap*
From
Approved Flexible
Gas Hose (if allowed
by local codes)
Gas Meter
(5" W.C.** to
10.5" W.C.
Pressure)
Gas
Regulator
Tee Joint
Pipe
Nipple
3" Minimum
Cap
Sediment
Trap
Figure 14 - Gas Connection
*PurchasetheoptionalA.G.A.design-certifiedmanualshutoffvalvefromyourdealer.
See Accessories, page 33.
** Minimum inlet pressure for purpose of input adjustment.
CHECKING GAS CONNECTIONS
WARNING
Test all gas piping and connections for leaks after installing or
servicing. Correct all leaks at once.
WARNING
Never use an open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming show a leak.
Correct all leaks at once.
CAUTION
Make sure external regulator has been installed between propane
supply and heater. See guidelines under Connecting to Gas Sup-
ply, page 15.
Pressure Testing gas Supply Piping system
Test Pressures In Excess Of 1/2 PSIG
1. Disconnect heater and its individual manual shutoff valve from gas supply
piping system. Pressures in excess of 1/2 psig will damage heater regulator.
2. Cap off open end of gas pipe where manual shutoff valve was connected.
Continued
17
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Pressurize supply piping system by either using compressed air or
opening propane supply tank valve.
INSTALLING
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and
water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
Continued
6. Re-connect heater and manual shutoff valve to gas supply. Check re-connected
fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG
1. Close manual shutoff valve (see Figure 15).
2. Pressurize supply piping system by either using compressed air or opening
propane supply tank valve.
3. Check all joints from propane supply tank to manual shutoff valve (see Figure
16). Apply mixture of liquid soap and water to gas joints. Bubbles forming
show a leak.
4. Correct all leaks at once.
Pressure Testing Heater Gas Connections
1. Open manual shutoff valve (see Figure 15).
2. Open propane supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to control valve (see Figure 16).
Apply mixture of liquid soap and water to gas joints. Bubbles forming show a
leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, pages 20 through 22 [manually-controlled
models] or pages 22 through 24 [thermostatically-controlled model]). Check all
other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appliance, page 21 [manually-con-
trolled models]) or page 24 [thermostatically-controlled model].).
O
p
e
n
Manual
Shutoff
Valve
Closed
Figure 15 - Manual Shutoff Valve
Manual
Shutoff
Valve
Thermostat Gas Valve or
Control Valve Location
Propane
Supply Tank
Figure 16 - Checking Gas Joints
18
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING LOGS
INSTALLING
Continued
WARNING
Failure to position the parts in accordance with these diagrams or failure
to use only parts specifically approved with this heater may result in
property damage or personal injury.
Each log is marked with a number. These numbers will help you identify the log
when installing. It is very important to install these logs exactly as instructed. Do
not modify logs. Only use logs supplied with heater.
1. Locate pegs on the bottom of back log (#1). Slide these pegs into the holes in
the grate base behind the burner (see Figure 17).
2. Place the base of the middle log (#2) in the U-shaped slots of the grate base in front
of the back log. The cutout on the right of the middle log should fit over the burner
(see Figure 18). Make sure the front of the middle log is resting on the tabs of the
grate base and the cutout area is centered over the burner “U” bend.
3. Locate the recesses on the back of the front log (#3). Fit these recesses between
the posts of the grate base (see Figure 19).
4. Locate the notches in the bottom of the crossover log (#4). Place the crossover
log on top of the middle log and front log. Make sure the notches of the cross-
over log lines up with rectangular knobs on top of the middle and front logs
(see Figure 20).
Back Log (#1)
Middle Log (#2)
Peg
Hole in
Grate Base
Tab
Burner
Cutout
“U” Bend
U-Shaped
Slot
Figure 17 - Installing Back Log (#1)
Figure 18 - Installing Middle Log (#2)
Front Log (#3)
Crossover
Log (#1)
Notches
3
Recess
Post
Rectangular
Knobs
Post
Figure 19 - Installing Front Log (#3)
Figure 20 - Installing Crossover Log (#4)
19
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING
FOR YOUR SAFETY READ BEFORE LIGHTING
HEATER
Manually-
Controlled Models
WARNING
If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell
next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t try to repair it, call a qualified service
technician or gas supplier. Force or attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been under water. Immediately call a
qualified service technician to inspect the appliance and to replace any part of the
control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
WARNING
• If fireplace has glass doors, never operate this heater with glass doors
closed. If you operate heater with doors closed, heat buildup inside
fireplace will cause glass to burst. Also if fireplace opening has vents at
the bottom, you must open the vents before operating heater.
• You must operate this heater with a fireplace screen in place. Make sure
fireplace screen is closed before running heater.
NOTICE
During initial operation of new heater, burning logs will give off a paper-
burning smell. Orange flame will also be present. Open damper or
window to vent smell. This will only last a few hours.
Note: Homeowners generally prefer to operate their heater with the chimney damper
closed. This will put all the heat into the room. However there may be times you will
desire the full flames of the Hi heat setting but will find the heat output excessive. You
can open the chimney damper (if you have one) fully or partially to release some of
the heat. WARNING: Damper handle will be hot if heater has been running.
1. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
Clockwise
3. Press in and turn control knob clockwise
to the OFF position.
Control Knob
Ignitor Button
HI
PILOT
OFF
LO
Figure 21 - Control Knob and Ignitor Button Location
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B” in the safety information above. If you
don’t smell gas, go to the next step.
20
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
C-clockwise
5. Slightly depress and turn control knob counterclockwise
position. Press in control knob for five (5) seconds (see Page 20).
to the PILOT
OPERATING
HEATER
Manually-
Note: You may be running this heater for the first time after hooking up to gas
supply. If so, the control knob may need to be pressed in for 30 seconds. This
will allow air to bleed from the gas system.
Controlled Models
Continued
6. With control knob pressed in, press and release ignitor button. This will light
pilot. The pilot is attached to the burner. If needed, keep pressing ignitor button
until pilot lights.
Note: If pilot does not stay lit, contact a qualified service person or gas supplier
for repairs. Until repairs are made, light pilot with match. To light pilot with
match, see Manual Lighting Procedure, page 22.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3 through 7.
Ignitor Electrode
Pilot Burner
Thermocouple
Figure 22 - Pilot
• If control knob does not pop out when released, contact a qualified service
person or gas supplier for repairs.
8. Slightly depress and turn control knob counterclockwise
to desired
C-clockwise
heating level. The burner should light. Set control knob to any heat level between
HI and LO.
WARNING
Do not operate heater between PILOT and HIGH positions.
VARIABLE CONTROL OPERATION
The variable control valve can be set to any heat setting and flame height desired, by
simply turning the control knob until that setting is attained. Even the lowest setting
provides realistic, dancing yellow flames. Selecting higher settings produces greater
heat output. This results in increased heating comfort.
CAUTION
Do not try to adjust heating levels by using the manual shutoff valve.
TO TURN OFF GAS TOAPPLIANCE
Shutting Off Heater
1. Press in and turn control knob clockwise
to the HIGH position.
Clockwise
2. Turn control knob clockwise to the pilot position.
Clockwise
3. Press in control knob and turn clockwise
to the OFF position.
Clockwise
Shutting Off Burners Only (pilot stays lit)
1. Turn control knob clockwise
to the HIGH position.
to the pilot position.
Clockwise
2. Press in and turn control knob clockwise
Clockwise
Continued
21
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions, pages 20 and 21.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8 on page 21.
HEATER
Continued
OPERATING
FOR YOUR SAFETY READ BEFORE LIGHTING
HEATER
Thermostatically-
Controlled Model
WARNING
If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell
next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t try to repair it, call a qualified service
technician or gas supplier. Force or attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been under water. Immediately call a
qualified service technician to inspect the appliance and to replace any part of the
control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
WARNING
• If fireplace has glass doors, never operate this heater with glass doors
closed. If you operate heater with doors closed, heat buildup inside
fireplacewillcauseglasstoburst. Alsoiffireplaceopeninghasventsatthe
bottom, you must open the vents before operating heater.
• You must operate this heater with a fireplace screen in place. Make sure
fireplace screen is closed before running heater.
NOTICE
During initial operation of new heater, burning logs will give off a paper-
burning smell. Orange flame will also be present. Open damper or window
to vent smell. This will only last a few hours.
Note: Homeowners generally prefer to operate their heater with the chimney damper
closed. This will put all the heat into the room. However there may be times you will
desire the full flames of the Hi heat setting but will find the heat output excessive. You
can open the chimney damper (if you have one) fully or partially to release some of
the heat. WARNING: Damper handle will be hot if heater has been running.
22
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
1. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
OPERATING
HEATER
Thermostatically-
Controlled Model
Continued
Clockwise
3. Turn control knob clockwise
to the OFF position.
Control Knob
Ignitor Button
Figure 23 - Control Knob and Ignitor Button Location
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B” in the safety information above. If you
don’t smell gas, go to the next step.
C-clockwise
5. Turn control knob counterclockwise
to the PILOT position. Press in
control knob for five (5) seconds (see above).
Note: You may be running this heater for the first time after hooking up to gas
supply. If so, the control knob may need to be pressed in for 30 seconds or less.
This will allow air to bleed from the gas system.
• If control knob does not pop out when released, contact a qualified service
person or gas supplier for repairs.
6. With control knob pressed in, press and release ignitor button. This will light
pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor
button until pilot lights.
Note: If pilot does not stay lit, contact a qualified service person or gas supplier
for repairs. Until repairs are made, light pilot with match. To light pilot with
match, see Manual Lighting Procedure on page 24.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety
interlock system. Wait one (1) minute for system to reset before lighting pilot
again.
Ignitor Electrode
Pilot Burner
Thermocouple
Figure 24 - Pilot
8. Turn control knob counterclockwise
to desired heating level. The
C-clockwise
burners should light. Set control knob to any heat level between HI and LO.
CAUTION
Do not try to adjust heating levels by using the manual shutoff valve.
Continued
23
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
TO TURN OFF GAS TO APPLIANCE
OPERATING
Shutting Off Heater
1. Turn control knob clockwise
Shutting Off Burners Only (pilot stays lit)
1. Turn control knob clockwise to the PILOT position.
HEATER
Thermostatically-
Controlled Model
Continued
to the OFF position.
Clockwise
Clockwise
THERMOSTAT CONTROL OPERATION
(Thermostat-Controlled Models Only)
The thermostat control knob can be set to any comfort level between Hi and Lo. The
thermostat will gradually modulate the heat output and flame height from higher to
lower settings, or pilot, in order to maintain the comfort level you select. The ideal
comfort setting will vary by household depending upon the amount of space to be
heated, the output of the central heating system, etc.
Note: Selecting the Hi setting with the control knob will cause the burner to remain
fully on, without modulating down in most cases.
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions, page 23.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8, page 23.
Check pilot flame pattern and burner flame patterns often.
INSPECTING
BURNERS
PILOT FLAME PATTERN
Figure 25 shows a correct pilot flame pattern. Figure 26 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the
thermocouple to cool. When the thermocouple cools, the heater will shut down.
Thermocouple
Thermocouple
Pilot Burner
Pilot Burner
Figure 25 - Correct Pilot
Flame Pattern
Figure 26 - Incorrect Pilot
Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 24
• turn heater off (see To Turn Off Gas to Appliance, page 21 [manually-con-
trolled models] or above [thermostat-controlled model])
• see Troubleshooting, pages 25 through 28
24
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING
AND
WARNING
Turn off heater and let cool before cleaning.
MAINTENANCE
CAUTION
You must keep control areas, burner, and circulating air passage-
ways of heater clean. Inspect these areas of heater before each
use. Have heater inspected yearly by a qualified service person.
Heater may need more frequent cleaning due to excessive lint
from carpeting, bedding material, etc.
ODS/PILOT AND BURNER
• Use a vacuum cleaner or small, soft bristled brush to clean.
LOGS
• If you remove logs for cleaning, refer to Installing Logs, page 19, to properly
replace logs.
• Replace log(s) if broken or chipped (dime-sized or larger).
TROUBLE-
SHOOTING
WARNING
Turn off and unplug heater and let cool before servicing. Only a
qualified service person should service and repair heater.
Note: All trouble-
shooting items are
listed in order of
operation.
CAUTION
Never use a wire, needle, or similar object to clean ODS/pilot. This
can damage ODS/pilot unit.
OBSERVED
PROBLEM
POSSIBLE
CAUSE
REMEDY
When ignitor button 1. Ignitor electrode not con- 1. Reconnect ignitor cable
is pressed, there is no
spark at ODS/pilot
nected to ignitor cable
2. Ignitor cable pinched or
wet
2. Free ignitor cable if
pinched by any metal or
tubing. Keep ignitor
cable dry
3. Piezo ignitor nut is loose 3. Tighten nut holding
piezo ignitor to base
panel of log set. Nut is
located behind base
panel.
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode posi-
tioned wrong
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace piezo ignitor
7. Replace piezo ignitor
Continued
25
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
OBSERVED
PROBLEM
POSSIBLE
CAUSE
TROUBLE-
REMEDY
SHOOTING
When ignitor button
is pressed, there is
spark at ODS/pilot
but no ignition
1. Gas supply turned off or 1. Turn on gas supply or
Continued
manual shutoff valve
closed
open manual shutoff
valve
2. Control knob not in
PILOT position
2. Turn control knob to
PILOT position
3. Control knob not
pressed in while in
PILOT position
3. Press in control knob
while in PILOT position
4. Air in gas lines when
installed
4. Continue holding down
control knob. Repeat
igniting operation until
air is removed
5. Depleted gas supply
6. ODS/pilot is clogged
5. Contact local propane
gas company
6. Clean ODS/pilot (see
Cleaning and Mainte-
nance, page 25) or
replace ODS/pilot
assembly
7. Gas regulator setting is
not correct
7. Replace gas regulator
ODS/pilot lights but
flame goes out when
control knob is
released
1. Control knob not fully
pressed in
2. Control knob not
pressed in long enough
1. Press in control knob
fully
2. After ODS/pilot lights,
keep control knob
pressed in 30 seconds
3. Fully open manual shut-
off valve
3. Manual shutoff valve
not fully open
4. Pilot flame not touching
thermocouple, which
allows thermocouple to
cool, causing pilot flame
to go out. This problem
could be caused by one
or both of the following:
A) Low gas pressure
B) Dirty or partially
clogged ODS/pilot
4. A) Contact local pro-
pane gas company
B) Clean ODS/pilot (see
Cleaning and Mainte-
nance, page 25) or
replace ODS/pilot
assembly
5. Thermocouple connec-
tion loose at control
valve
5. Hand tighten until snug,
then tighten 1/4 turn
more
6. Thermocouple damaged 6. Replace thermocouple
7. Control valve damaged 7. Replace control valve
26
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
OBSERVED
PROBLEM
POSSIBLE
CAUSE
TROUBLE-
REMEDY
SHOOTING
Burner does light
after ODS/pilot is lit
1. Burner orifice clogged
1. Clean burner (see
Cleaning and Mainte-
nance, page 25) or
Continued
replace burner orifice
2. Contact local propane
gas company
2. Inlet gas pressure is
too low
3. Burner orifice diameter 3. Replace burner orifice
is too small
Delayed ignition of
burner
1. Manifold pressure is
too low
2. Burner orifice clogged
1. Contact local natural gas
company
2. Clean burner (see
Cleaning and Mainte-
nance, page 25) or
replace burner orifice
Burner backfiring
during combustion
1. Burner orifice is
clogged or damaged
1. Clean burner (see
Cleaning and Mainte-
nance, page 25) or
replace burner orifice
2. Replace damaged burner
3. Replace gas regulator
2. Damaged burner
3. Gas regulator defective
Slight smoke or
odor during initial
operation
1. Not enough air
1. Check burner for dirt
and debris. If found,
clean burner (see
Cleaning and Mainte-
nance, page 25)
2. Gas regulator defective
3. Residues from manu-
facturing processes
2. Replace gas regulator
3. Problem will stop after a
few hours of operation
and logs curing
Moisture/condensa-
tion noticed on
windows
1. Not enough combus-
tion/ventilation air
1. Refer to Air for Com-
bustion and Ventilation
requirements (page 5)
Heater produces a
whistling noise
when burner is lit
1. Turning control knob
to HI position when
burner is cold
1. Turn control knob to LO
position and let warm up
for a minute
2. Air in gas line
2. Operate burner until air
is removed from line.
Have gas line checked
by local natural gas
company
3. Air passageways on
heater blocked
3. Observe minimum
installation clearances
(see pages 9-12)
4. Dirty or partially
4. Clean burner (see
Cleaning and Maintenance,
page 25) or replace
burner orifice
clogged burner orifice
27
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLE-
WARNING
If you smell gas
• Shut off gas supply.
SHOOTING
Continued
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors.
Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new
carpet or textiles, etc., create fumes. These fumes may mix with combustion air
and create odors. These odors will disappear over time.
POSSIBLE
CAUSE
OBSERVED
PROBLEM
REMEDY
1. Metal expanding while
heating or contracting
while cooling
Heater produces a
clicking/ticking noise
just after burner is lit
or shut off
1. This is common with
most heaters. If noise is
excessive, contact
qualified service person
1. Heater burning vapors
from paint, hair spray,
glues, cleaners, chemi-
cals, new carpet, etc.
(See IMPORTANT
Heater produces
unwanted odors
1. Open window and
ventilate room. Stop using
odor causing products
while heater is running
statement above)
2. Gas leak. See Warning
statement at top of
page
2. Locate and correct all
leaks (see Checking Gas
Connections, page 17)
1. Not enough fresh air is
available
Heater shuts off in use
(ODS operates)
1. Open window and/or door
for ventilation
2. Low line pressure
2. Contact local natural gas
company
3. ODS/pilot is partially
clogged
3. Clean ODS/pilot (see
Cleaning and Mainte-
nance, page 25)
1. Gas leak. See Warning
statement at top of
page
Gas odor even when
control knob is in OFF
position
1. Locate and correct all
leaks (see Checking Gas
Connections, page 17)
2. Replace control valve
2. Control valve defective
1. Foreign matter between
control valve and burner
2. Gas leak. See Warning
statement at top of
page
Gas odor during
combustion
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all
leaks (see Checking Gas
Connections, page 17)
1. Thermostat sensing bulb
needs to be repositioned.
Logs set cycles to
pilot, but room
temperature drops to a
lower than ideal level
before log set comes
back on
1. Reposition thermostat
sensing bulb (see instruc-
tions for Optional
Positioning of Thermostat
Sensing Bulb, page 29.
28
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
If your log set cycles to pilot, but the room temperature drops to a lower than
ideal comfort level before the log set comes back on, you may want to
reposition the thermostat sensing bulb.
OPTIONAL
POSITIONING
OF
The thermostat sensing bulb is located near the gas valve assembly on the mounting
bracket. This location allows the thermostat to keep the room temperature at an ideal
comfort level for most fireplace applications. For positioning the thermostat sensing bulb
elsewhere, an adhesive-backed mounting clip has been provided.
THERMOSTAT
SENSING BULB
Tools needed: 1/4" hex driver or socket
For Masonry and
Factory-built
1. Remove logs. Locate the gas valve assembly and thermostat sensing blub (see Figure 27).
Gas Valve
Assembly
Metal Fireplace
Mounting
Thermostat
Bracket
Sensing Bulb
Figure 27 - Location of Gas Valve Assembly and Thermostat Sensing Bulb
2. The adhesive-backed mounting clip (see Figure 28) is attached to the thermostat sensing
bulb. Remove the adhesive-backed mounting clip.
Figure 28 - Adhesive-backed Mounting Clip
3. With 1/4" hex driver or socket, loosen the thermostat screw. Carefully slide the thermo-
stat sensing bulb out of the retaining clamp (see Figure 29).
Note: Do not remove the screw. Make sure you tighten the screw after removing the
thermostat sensing bulb.
IMPORTANT: Do not force or bend the thermostat sensing bulb or capillary.
Capillary
Thermostat Screw
Retaining Clamp
Thermostat
Sensing Bulb
Figure 29 - Removing Thermostat Sensing Bulb
4. The thermostat sensing bulb may be located to the lower right front side of fireplace.
Determine location of sensing bulb, but do not mount sensing bulb until step 5. If you
have a masonry fireplace, see Figure 30 on page 30 for location.
Continued
29
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
Thermostat
Sensing Bulb
OPTIONAL
POSITIONING
OF
Adhesive-backed
Mounting Clip
THERMOSTAT
SENSING BULB
Figure 30 - Locating Thermostat Sensing Bulb on Masonry Fireplace
For Masonry and
Factory-built
Metal Fireplace
Continued
If you have a factory-built metal fireplace, see Figure 31 for location.
Thermostat
Sensing Bulb
Adhesive-backed
Mounting Clip
Figure 31 - Locating Thermostat Sensing Bulb on Factory-built Metal Fireplace
If your fireplace has glass doors, position sensing bulb directly behind door gap on right
bottom side (see Figure 32).
Thermostat
Sensing Bulb
Adhesive-backed
Mounting Clip
Glass
Doors
Figure 32 - Installing Thermostat Sensing Bulb behind Glass Doors
5. The mounting clip must be a minimum of 3" from bottom of fireplace to
prevent crimping of capillary. Once you have decided on a location, clean the
area thoroughly. Remove the paper backing from the adhesive on back of
mounting clip. Press the clip into the new location so that the thermostat
sensing bulb will be positioned vertically with the capillary at the bottom (see
Figure 33). Slide the thermostat sensing bulb into the clip.
IMPORTANT: Do not crimp capillary.
Thermostat
Sensing Bulb
Adhesive-backed
Mounting Clip
Capillary
Do Not Crimp Capillary
Figure 33 - Positioning the Thermostat Sensing Bulb in the Vertical
Position with the Capillary at the Bottom
30
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at
1-800-DESA LOG (1-800-337-2564).
TECHNICAL
SERVICE
18" Model
24" Models
30" Model
SPECIFICATIONS
Btu (Variable)
Type Gas
16,000/30,000
20,000/39,000
20,000/39,000
Propane Only
Piezo
Propane Only
Piezo
Propane Only
Piezo
Ignition
Manifold Pressure
8.0" W.C.
8.0" W.C.
8.0" W.C.
Inlet Gas
Pressure (in. of water)
Maximum
14"
11"
14"
11"
14"
11"
Minimum*
Shipping Weight
28 lbs.
30 lbs.
32 lbs.
* For the purpose of input adjustment
When gas pressure is too low
• pilot will not stay lit
SERVICE
HINTS
• burners will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.
31
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: Use only original replacement parts. This will protect your warranty cover-
age for parts replaced under warranty.
REPLACEMENT
PARTS
Parts Under Warranty
Contact authorized dealers of this product. If they can’t supply original replace-
ment part(s), call DESA International’s Technical Service Department at
1-800-DESA LOG (1-800-337-2564).
When calling DESA International, have ready
• your name
• your address
• model number of your heater
• how heater was malfunctioning
• type of gas used (propane or natural gas)
• purchase date
Usually, we will ask you to return the defective part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product. If they can’t supply original replace-
ment part(s), call DESA International’s Parts Department at 1-800-972-7879 for
referral information.
When calling DESA International, have ready
• model number of your heater
• the replacement part number
These Parts Centrals are privately owned businesses. They have agreed to support
our customer’s needs by providing original replacement parts and accessories.
PARTS
CENTRAL
Baltimore Electric
1348 Dixwell Avenue
Hamden, CT 06514
1-800-397-7553
Washer Equipment Co.
1715 Main Street
Kansas City, MO 64108
KS, MO, AR
Dayton Hardware
P.O. Box 275
North Dayton Station
Dayton, OH 45404
All States
203-248-7553
816-842-3911
Parts Department
513-258-3721
East Coast Energy
Products
833 Broadway
W. Long Branch, NJ
07764
OH 1-800-762-3426
Portable Heater Parts
342 N. County Rd. 400 East
Valparaiso, IN 46383
All States
219-462-7441
1-800-362-6951
Halco Enterprises
208 Carter Drive, Unit 21
West Chester, PA 19382
215-696-2670
908-870-8809
1-800-755-8809
1-800-368-0803
FBD
Tarantin Tank Co.
P.O. Box 6129
Freehold, NJ 07728
908-780-9340
LA Porte’s Parts &
Service
2444 N. 5th Street
Hartsville, SC 29550
803-332-0191
601 Hope Street
Bowling Green, KY 42101
502-796-8406
1-800-654-8534
1-800-922-0724
Parts Department
Four Flags Power Products
1115 Stateline Road
Niles, MI 49120
616-684-2697
Parts Only
Albany Ladder
1586-90 Central Avenue
Albany, NY 12205
NY, MA, VT
Cans Unlimited, Inc.
P.O. Box 645
Taylor, SC 29687
All States
518-869-5335
1-800-354-7368
803-879-3009
1-800-845-5301
Master Service Center
1184 Wilson NW
Walker, MI 49504
616-791-4760
1-800-446-1446
32
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
Purchase these fireplace accessories from your local dealer. If they can not supply
these accessories, call DESA International’s Sales Department at 1-800-472-7879
for referral information. You can also write to the address listed on the back page
of this manual.
ACCESSORIES
MANUAL SHUTOFF
VALVE - GA5010
For all models. Manual shutoff valve
with 1/8" NPT tap. Fits 1/2" NPT
pipe.
BLACK FIREPLACE
HOOD - GA6050
For all models. Helps
deflect heat away from
mantel or wall above
fireplace.
BRASS FIREPLACE
HOOD - GA6052
For all models. Helps
deflect heat away from
mantel or wall above
fireplace.
DAMPER CLAMP - GA6080
For variably controlled models.
Permanently opens chimney flue
damper for vented operation.
LAVA ROCK - GA6060
For all models. Order when additional
rock is desired. (3 lb. bag)
33
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
ILLUSTRATED
PARTS
BREAKDOWN
Variable Manually-
Controlled Models
1
4
3
2
CGD3018P
CGD3924P
CGD3930P
20-2
24
20-1
20
18
12
19
25
11
10
13
7
8
6
22
9
21
5
14
18
23
22
19
17
15
16
22
34
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
This list contains replaceable parts used in your heater. When ordering parts, follow
the instructions listed under Replacement Parts on page 33 of this manual.
PARTS LIST
KEY
NO.
CGD3018P
PART NUMBER
CGD3924P
PART NUMBER
CGD3930P
PART NUMBER
DESCRIPTION
QTY.
1
2
3
4
5
6
7
8
103008-02
103009-02
103010-02
103011-02
102774-04BR
102844-02
102966-02
098867-10
102798-01
102779-04
099056-19
102843-01
102980-01
102568-08
098508-01
098354-01
102445-01
099387-08
098271-07
099059-02
103008-01
103009-01
103010-01
103011-01
102774-01BR
102844-01
102966-01
098867-10
102798-01
102779-02
099056-17
102843-01
102772-01
102568-06
098508-01
098354-01
102445-01
099387-08
098271-07
099059-02
099594-01
098593-01
M11084-38
098304-03
098276-01
098249-01
099553-01
103008-03
103009-03
103010-03
103011-03
102774-03BR
102844-01
102966-01
098867-10
102798-01
102779-02
099056-17
102843-01
102772-01
102568-06
098508-01
098354-01
102445-01
099387-08
098271-07
099059-02
099594-01
098593-01
M11084-38
098304-03
098276-01
098249-01
099553-01
Back Log (#1)
Middle Log (#2)
Front Log (#3)
Crossover Log (#4)
Painted Base Assembly
Lower Bracket
Upper Bracket
Gas Regulator
Inlet Tube
Outlet Burner Tube
Burner Orifice Injector
Burner Clip
Burner
Control Valve
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
9
1
2
1
9
10
11
12
13
14
15
16
17
18
19
20
Valve Retainer Nut
Control Knob
Piezo Ignitor
Pilot Tube
Ignitor Cable
ODS Pilot
20-1 099594-01
20-2 098593-01
21
22
23
24
25
Ignitor Electrode
Thermocouple
Regulator Screw
Black Screw, PPH #8-18
Hex Head Plug, 1/8 NPT
Nut, M5
M11084-38
098304-03
098276-01
098249-01
099553-01
Pilot Shield
PARTS AVAILABLE — NOT SHOWN
100563-01
101055-02
100565-01
100639-01
101449-04
101137-02
101416-18
GA6060
100563-01
100563-01
101055-02
100565-01
100639-01
101449-04
101137-02
101416-18
GA6060
Warning Plate
1
1
1
1
1
1
1
1
101055-02
100565-01
100639-01
101449-04
101137-02
101416-18
GA6060
Lighting Instructions Plate
Warning Plate Fastener
Caution Decal
Control Position Decal
Hardware Kit
Information Video
Lava Rock
35
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
ILLUSTRATED
PARTS
BREAKDOWN
Thermostatically-
Controlled Manuals
1
4
3
2
CGD3924PT
20-2
20-1
20
18
12
24
19
23
11
10
13
7
25
9
14
8
6
21
15
22
22
16
5
22
19
17
22
36
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
This list contains replaceable parts used in your heater. When ordering parts, follow
the instructions listed under Replacement Parts on page 33 of this manual.
PARTS LIST
KEY
NO.
CGD3924PT
PART NUMBER
DESCRIPTION
QTY.
1
2
3
4
5
6
7
8
103008-01
103009-01
103010-01
103011-01
102774-05BR
102844-01
102966-01
098867-10
102981-01
102983-02
099056-17
102843-01
102772-01
101329-19
102979-01
098544-01
102445-01
099387-09
098271-07
099059-02
Back Log (#1)
Middle Log (#2)
Front Log (#3)
Crossover Log (#4)
Painted Base Assembly
Lower Bracket
Upper Bracket
Gas Regulator
Inlet Tube
Outlet Burner Tube
Burner Orifice Injector
Burner Clip
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
13
1
2
2
9
10
11
12
13
14
15
16
17
18
19
20
Burner
Thermostat Gas Valve Assembly
Thermostat Bracket
Thermobulb Clip
Piezo Ignitor
Pilot Tube
Ignitor Cable
ODS Pilot
Ignitor Electrode
Thermocouple
Regulator Screw
Black Screw, PPH #8-18
Pilot Shield
20-1 099594-01
20-2 098593-01
21
22
23
24
25
M11084-38
098304-03
099553-01
098249-01
099211-01
Nut, M5
Hex Screw, 10-16 x 2.50
PARTS AVAILABLE — NOT SHOWN
100563-01
101054-01
100565-01
100639-01
101137-02
101416-18
GA6060
Warning Plate
1
1
1
1
1
1
1
Lighting Instructions Plate
Warning Plate Fastener
Caution Decal
Hardware Kit
Information Video
Lava Rock
37
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
NOTES
38
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
________________________________________________________________
NOTES
39
102991
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard
written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
COMFORT GLOW VENT-FREE PROPANE GAS LOG HEATERS
DESA International warrants this product to be free from defects in materials and components for one (1) year from the date
of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all
applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this
heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center.
Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide
original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST
be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or
become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation.
Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be
the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE
PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND
LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR ON ALL COMPONENTS
FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO
THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY
OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or
consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply
to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
102991-01
Rev. A
06/96
Download from Www.Somanuals.com. All Manuals Search And Download.
|