Desa Outdoor Fireplace VMH26TNA User Manual

®
VENT-FREE NATURAL GAS  
COMPACT CLASSIC HEARTH® FIREPLACE  
OWNER’S OPERATION AND INSTALLATION MANUAL  
VMH26TNA  
14,000 to 26,000 Btu/Hr  
with Thermostat  
Shown with Optional  
Cabinet Mantel/Hearth  
Base Accessory  
WARNING: Improper installa-  
WARNING: If the information in this manual  
tion,adjustment,alteration,ser-  
is not followed exactly, a fire or explosion  
vice,ormaintenancecancause  
may result causing property damage, per-  
sonal injury, or loss of life.  
injury or property damage. Re-  
fer to this manual for correct  
Do not store or use gasoline or other  
installationandoperationalpro-  
cedures. For assistance or ad-  
ditional information consult a  
qualified installer, service  
agency, or the gas supplier.  
flammable vapors and liquids in the vicinity  
of this or any other appliance.  
WHAT TO DO IF YOU SMELL GAS  
• Do not try to light any appliance.  
• Do not touch any electrical switch; do not  
use any phone in your building.  
• Immediately call your gas supplier from a  
neighbor’s phone. Follow the gas  
supplier’s instructions.  
WARNING:Thisisanunvented  
gas-fired heater. It uses air  
(oxygen) from the room in  
whichitisinstalled.Provisions  
for adequate combustion and  
ventilation air must be pro-  
vided.RefertoAirforCombus-  
tion and Ventilation section on  
page 5 of this manual.  
• If you cannot reach your gas supplier, call  
the fire department.  
Installation and service must be per-  
formed by a qualified installer, service  
agency, or the gas supplier.  
This appliance may be installed in an aftermarket*, permanently located, manufactured  
(mobile) home, where not prohibited by local codes.  
This appliance is only for use with the type of gas indicated on the rating plate. This  
appliance is not convertible for use with other gases.  
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer  
Save this manual for future reference.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
PRODUCT  
PRODUCT  
IDENTIFICATION  
FEATURES  
Fireplace  
Cabinet  
SAFETY PILOT  
This fireplace has a pilot with an Oxygen  
Depletion Sensor Shutoff System (ODS).  
The ODS/pilot is a required feature for vent-  
freeroomfireplaces.TheODS/pilotshutsoff  
the fireplace if there is not enough fresh air.  
PIEZO IGNITION SYSTEM  
This fireplace has a piezo ignitor. This sys-  
tem requires no matches, batteries, or other  
sources to light fireplace.  
Screen  
THERMOSTATIC HEAT  
CONTROL  
This fireplace has a thermostat sensing bulb  
and a control valve. The thermostat will  
automatically modulate the heat output to  
maintain a consistent room temperature.  
This results in greater fireplace comfort.  
This can also result in lower gas bill.  
Logs  
Control Knob  
Ignitor Button  
Figure 1 - Vent-Free Natural Gas Compact Fireplace  
LOCAL CODES  
UNPACKING  
1. Remove log box and fireplace from  
carton. The hood is not attached.  
Install and use fireplace with care. Follow all  
localcodes.Intheabsenceoflocalcodes,use  
the latest edition of The National Fuel Gas  
CodeANSZ223.1,alsoknownasNFPA54*.  
2. Remove all protective packaging ap-  
plied to fireplace for shipment.  
3. Make sure your fireplace includes one  
hardware packet.  
*Available from:  
American National Standards Institute, Inc.  
1430 Broadway  
4. Check fireplace for any shipping  
damage. If fireplace is damaged,  
promptly inform dealer where you  
bought fireplace.  
New York, NY 10018  
National Fire Protection Association, Inc.  
Batterymarch Park  
Quincy, MA 02269  
104060  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
Screen  
ASSEMBLY  
Shipping  
Back Log  
Screw  
Shoulder  
WARNING: Always have  
branch support and screen in  
place before operating fireplace.  
Thispreventsexcessivetempera-  
tures on fireplace surfaces.  
Screw  
Burner  
Support  
WARNING: Failure to position  
thepartsinaccordancewiththese  
diagrams or failure to use only  
parts specifically approved with  
this fireplace may result in prop-  
erty damage or personal injury  
Screw  
ASSEMBLING FIREPLACE  
Tools Required:  
• Phillips screwdriver  
• 5/16" hex wrench  
• slotted screwdriver  
Branch  
Support  
Installing Log  
1. Remove back log, branch, and hood from  
log box. Discard protective packaging.  
Screw  
Screen  
Branch  
2. Remove two shipping screws above  
screen (see Figure 2).  
Figure 2 - Assembling Fireplace  
3. Lift screen up and pull out to remove.  
Assembling Hood  
4. An optional blower is available. See  
Accessories, page 27. Install optional  
blower now. Follow installation in-  
structions provided with blower.  
1. Locate four #10-3/8" black phillips  
sheet metal screws from the hardware  
packet.  
5. Gently place back log on burner sup-  
port (see Figure 2). The log should fit  
flat against top of burner support. Place  
two #10 one-inch-long screws through  
burner support into the log and tighten.  
2. Slip top of hood between middle rail and  
top of firebox wrapper (see Figure 3).  
3. Attach four #10-3/8" hood screws as  
shown in Figure 3.  
Upper Louver  
Assembly  
6. Place branch on branch support (see  
Figure 2). Do not allow branch to con-  
tact flame. If flame contacts branch,  
soot will be created.  
Middle  
Rail  
Firebox  
Wrapper  
7. Reattach screen by placing the notches  
in the screen frame over the shoulder  
screws and pushing down.  
Hood  
#10-3/8"  
Screws  
Figure 3 - Assembling Hood  
104060  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
Confined and Unconfined Space  
PROVIDING ADEQUATE  
VENTILATION  
AIR FOR  
The National Fuel Gas Code (ANS Z223.1,  
1992 Section 5.3) defines a confined space  
as a space whose volume is less than 50  
cubic feet per 1,000 Btu per hour (4.8 m3 per  
kw) of the aggregate input rating of all  
appliances installed in that space and an  
unconfining space as a space whose volume  
is not less than 50 cubic feet per 1,000 Btu  
per hour (4.8 m3 per kw) of the aggregate  
inputratingofallappliancesinstalledinthat  
space. Rooms communicating directly with  
the space in which the appliances are in-  
stalled*, through openings not furnished  
with doors, are considered a part of the  
unconfined space.  
COMBUSTION AND  
VENTILATION  
The following are excerpts from National  
Fuel Gas Code. NFPA 54/ANS Z223.1, Sec-  
tion5.3, AirforCombustionandVentilation.  
WARNING: This heater shall  
notbeinstalledinaconfinedspace  
or unusually tight construction  
unless provisions are provided  
foradequatecombustionandven-  
tilation air. Read the following in-  
structions to insure proper fresh  
air for this and other fuel-burning  
appliances in your home.  
All spaces in homes fall into one of the three  
following ventilation classifications:  
1. Unusually Tight Construction  
2. Unconfined Space  
3. Confined Space  
The information on pages 5 through 7 will  
help you classify your space and provide  
adequate ventilation.  
Today’s homes are built more energy effi-  
cient than ever. New materials, increased  
insulation, and new construction methods  
helpreduceheatlossinhomes.Homeowners  
weather strip and caulk around windows and  
doorstokeepthecoldairoutandthewarmair  
in. During heating months, home owners  
want their homes as airtight as possible.  
Unusually Tight Construction  
This heater shall not be installed in a con-  
fined space or unusually tight construction  
unless provisions are provided for adequate  
combustion and ventilation air.  
The air that leaks around doors and win-  
dows may provide enough fresh air for  
combustion and ventilation. However, in  
buildings of unusually tight construction,  
you must provide additional fresh air.  
* Adjoining rooms are communicating only  
iftherearedoorlesspassagewaysorventila-  
tion grills between them.  
Unusually tight construction is de-  
fined as construction where:  
While it is good to make your home energy  
efficient, your home needs to breathe. Fresh  
air must enter your home. All fuel-burning  
appliances need fresh air for proper com-  
bustion and ventilation.  
a. walls and ceilings exposed to the  
outside atmosphere have a con-  
tinuous water vapor retarder with  
a rating of one perm (6 x 10-11 kg  
per pa-sec-m2) or less with open-  
ings gasketed or sealed and  
Exhaustfans, fireplaces, clothesdryers, and  
fuel burning appliances draw air from the  
house to operate. You must provide ad-  
equate fresh air for these appliances. This  
will insure proper venting of vented fuel-  
burning appliances.  
b. weather stripping has been  
added on openable windows and  
doors and  
c. caulking or sealants are applied  
to areas such as joints around  
window and door frames, be-  
tween sole plates and floors, be-  
tween wall-ceiling joints, be-  
tween wall panels, at penetra-  
tions for plumbing, electrical, and  
gas lines, and at other openings.  
If your home meets all of the three  
criteria above, you must provide ad-  
ditional fresh air. See Ventilation Air  
From Outdoors, page 7.  
If your home does not meet all of the  
three criteria above, proceed to De-  
termining Fresh-Air Flow For Fire-  
place Location, page 6.  
Continued  
104060  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
AIR FOR  
COMBUSTION AND  
VENTILATION  
Continued  
DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION  
Determining if You Have a Confined or Unconfined Space  
Use this worksheet to determine if you have a confined or unconfined space.  
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills  
between the rooms.  
1. Determine the volume of the space (length x width x height).  
Length x Width x Height = _________________cu. ft. (volume of space)  
Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) =2560 cu. ft. (volume of space)  
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of  
the space.  
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.  
_____________________(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)  
Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft = 51.2 or 51,200 (maximum Btu/Hr the space can support)  
3. Add the Btu/Hr of all fuel burning appliances in the space.  
Vent-free fireplace  
Gas water heater*  
Gas furnace  
Vented gas heater  
Gas fireplace logs  
__________________Btu/Hr  
__________________Btu/Hr  
__________________Btu/Hr  
__________________Btu/Hr  
__________________Btu/Hr  
Example:  
30,000  
26,000  
56,000  
Gas water heater  
Vent-free fireplace +  
Btu/Hr  
Btu/Hr  
Btu/Hr  
Total  
=
Other gas appliances* + __________________Btu/Hr  
Total = __________________Btu/Hr  
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.  
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.  
_________________ Btu/Hr (maximum the space can support)  
_________________ Btu/Hr (actual amount of Btu/Hr used)  
Example: 51,200 Btu/Hr (maximum the space can support)  
56,000 Btu/Hr (actual amount of Btu/Hr used)  
The space in the above example is a confinedspace because the actual Btu/Hr used is more than the maximum Btu/Hr the space cansupport.  
You must provide additional fresh air. Your options are as follows:  
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-  
ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.  
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7.  
C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.  
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no  
additional fresh air ventilation.  
WARNING:If the area in which the heater may be operated is smaller than that defined as an unconfined space  
or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of  
the methods described in the National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3 or applicable local codes.  
104060  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
AIR FOR  
COMBUSTION AND  
VENTILATION  
12"  
Continued  
VENTILATION AIR  
Ventilation Air From Inside  
Building  
Ventilation Grills  
Into Adjoining Room,  
Option 2  
Ventilation  
Grills  
Or  
Thisfreshairwouldcomefromanadjoining  
unconfined space. When ventilating to an  
adjoining unconfined space, you must pro-  
vide two permanent openings: one within  
12" of the ceiling and one within 12" of the  
floor on the wall connecting the two spaces  
(see options 1 and 2, Figure 4). You can also  
remove door into adjoining room (see op-  
tion 3, Figure 4). Follow the National Fuel  
Gas Code NFPA 54/ANS Z223.1, Section  
5.3, Air for Combustion and Ventilation for  
required size of ventilation grills or ducts.  
into Adjoining  
Room,  
Option 1  
Remove  
Door into  
Adjoining  
Room,  
Option 3  
12"  
WARNING: Rework work-  
sheet, adding the space of the  
adjoining unconfined space. The  
combined spaces must have  
enough fresh air to supply all  
appliances in both spaces.  
Figure 4 - Ventilation Air from Inside Building Shown with Optional Mantel  
Ventilation Air From Outdoors  
Ventilated  
Provide extra fresh air by using ventilation  
grills or ducts. You must provide two per-  
manent openings: one within 12" of the  
ceiling and one within 12" of the floor.  
Connect these items directly to the outdoors  
orspacesopentotheoutdoors. Thesespaces  
include attics and crawl spaces. Follow the  
National Fuel Gas Code NFPA 54/ANS  
Z223.1, Section5.3, AirforCombustionand  
Ventilation for required size of ventilation  
grills or ducts.  
Outlet  
Attic  
Air  
Outlet  
Air  
To Attic  
To  
Crawl  
Space  
IMPORTANT: Do not provide openings for  
inlet or outlet air into attic if attic has a  
thermostat-controlledpowervent. Heatedair  
enteringtheatticwillactivatethepowervent.  
Inlet  
Air  
Ventilated  
Inlet Air  
Crawl Space  
Figure 5 - Ventilation Air from Outdoors Shown with Optional Mantel  
104060  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
Note: Your Vanguard fireplace is designed  
INSTALLATION  
CAUTION: If you install the  
to be used in zero clearance installations.  
Wall or framing material can be placed  
directly against any exterior surface on the  
rear, sides, or top of your fireplace, except  
where stand-off spacers are integrally at-  
tached. If standoff spacers are attached to  
your fireplace, these spacers can be placed  
directly against wall or framing materials.  
fireplace in a home garage  
• fireplace pilot and burner must  
beatleast18inchesabovefloor.  
• locate fireplace where moving  
vehicle will not hit it.  
NOTICE: This heater is intended  
foruseassupplementalheat.Use  
this heater along with your pri-  
mary heating system. Do not in-  
stall this heater as your primary  
heat source. If you have a central  
heating system, you may run  
system’scirculatingblowerwhile  
using heater. This will help circu-  
late the heat throughout the  
house. In the event of a power  
outage, you can use this heater  
as your primary heat source.  
For convenience and efficiency, install  
fireplace  
Use the dimensions shown for rough open-  
ings to create the easiest installation (see  
Built-In Fireplace Installation, page 9).  
• where there is easy access for operation,  
inspection, and service.  
• in coldest part of room.  
An optional blower kit is available from  
your dealer. See Accessories, page 27. If  
planningtouseblower,locatefireplacenear  
an electrical outlet.  
CHECK GAS TYPE  
Use only natural gas. If your gas supply is  
not natural gas, do not install fireplace. Call  
dealerwhereyouboughtfireplaceforproper  
type fireplace.  
WARNING: A qualified ser-  
vicepersonmustinstallfireplace.  
Follow all local codes.  
CEILING  
INSTALLATION ITEMS  
36"  
Minimum  
Before installing fireplace, make sure you  
have the items listed below.  
WARNING: Never install the  
fireplace  
6"  
• piping (check local codes)  
• sealant (resistant to propane/LP gas)  
• manual shutoff valve *  
• test gauge connection *  
• ground joint union  
• sediment trap  
Minimum  
From  
• in a bedroom or a bathroom  
• in a recreational vehicle  
• where curtains, furniture,  
clothing, or other flammable  
objectsarelessthan36inches  
from the front, top, or sides of  
the fireplace  
• as a fireplace insert  
• in high traffic areas  
• in windy or drafty areas  
Sides Of  
Fireplace  
Left  
Side  
Right  
Side  
• tee joint  
• pipe wrench  
* AnA.G.A.design-certifiedmanualshutoff  
valve with 1/8" NPT tap is an acceptable  
alternative to test gauge connection. Pur-  
chase the optional A.G.A. design-certified  
manual shutoff valve from your dealer. See  
Accessories, page 27.  
FLOOR  
Figure6-MountingClearancesAsViewed  
From Front of Fireplace Shown Built In  
The Wall  
CAUTION: This fireplace cre-  
ates warm air currents. These  
currents move heat to wall sur-  
faces next to fireplace. Installing  
fireplace next to vinyl or cloth  
wall coverings or operating fire-  
place where impurities (such as  
tobacco smoke, aromatic  
candles, cleaning fluids, oil or  
kerosene lamps, etc.) in the air  
exist, may discolor walls.  
CEILING  
Note:Ifdesired,purchaseafour-sidedbrass  
trim kit for built-in installations. See Acces-  
sories, page 27.  
Top Of  
Mantel Can  
36"  
Be Flush  
Minimum  
With Wall  
LOCATING FIREPLACE  
WARNING:Maintainthemini-  
mum clearances shown in Fig-  
ures 6 and 7. If you can, provide  
greater clearances from floor,  
ceiling, and joining wall.  
Right  
Side  
IMPORTANT:Vent-freefireplacesaddmois-  
ture to the air. Although this is beneficial,  
installing fireplace in rooms without enough  
ventilationairmaycausemildewtoformfrom  
too much moisture. See Air for Combustion  
and Ventilation, pages 5 through 7.  
Left  
Side  
You can recess firebox into the wall. You  
can also position fireplace in the optional  
cabinet or corner mantels. IMPORTANT:  
Only use optional cabinet or corner mantels  
specified in this manual. Purchase the op-  
tional mantel from your dealer (see Acces-  
sories, page 27).  
Figure7-MountingClearancesAsViewed  
From Front of Fireplace Shown with  
Optional Mantel  
104060  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
2. If installing GA3400(T) blower acces- 5. Carefully set fireplace in front of rough  
INSTALLATION  
sory, do so at this time. Follow instruc-  
opening with back of fireplace inside  
Continued  
tions included with blower accessory.  
wall opening.  
BUILT-IN FIREPLACE  
INSTALLATION  
Note: If not installing blower acces- 6. Attach flexible gas line to fireplace gas  
sory, you may wish to run electrical  
wiring to your fireplace for future  
blower installation (see Accessories,  
page 27) Use only approved three-wire  
electrical wiring.  
regulator. See Connecting Fireplace to  
Gas Supply, page 15.  
Built-ininstallationofthisfireplaceinvolves  
installing fireplace into a framed-in enclo-  
sure. This makes the front of fireplace flush  
with wall. An optional brass trim kit acces-  
sory is available (see Accessories, page 27).  
Brasstrimwillextendpastsidesoffireplace  
approximately 1/2 inch. This will cover the  
rough edges of the wall opening. If install-  
ingabuilt-inmantelabovethefireplaceyou  
must follow the clearances shown in Figure  
11, page 10. Follow the instructions below  
to install the fireplace in this manner.  
7. Bend four nailing flanges on outer cas-  
ing with pliers (see Figure 10).  
8. Attach fireplace to wall studs using  
nails or wood screws through holes in  
nailing flange.  
WARNING: If pre-wiring, do  
not connect wiring to any electri-  
cal source at this time.  
9. Check all gas connections for leaks. See  
Checking Gas Connections, page 16.  
Install fireplace electrical outlet  
and connect wiring to outlet be-  
fore connecting to electrical  
source. The fireplace electrical  
outlet is included with the  
GA3400(T) blower accessory.  
10. If using optional brass trim kit, install  
the trim after final finishing and/or  
painting of wall. See instructions in-  
cluded with brass trim accessory for at-  
taching brass trim.  
Actual Framing  
Height  
26"  
26 3/4"  
9 1/2"  
3/4"  
26 7/8"  
26 7/8"  
10 1/2"  
3/4"  
IMPORTANT: When finishing your fire-  
box, combustible materials such as wall  
board, gypsum board, sheet rock, drywall,  
plywood, etc. may be butted up next to the  
sides and top of the firebox. Combustible  
materials should never overlap the firebox  
front facing.  
Only use the fireplace electrical  
outlet supplied with the  
GA3400(T) blower accessory.  
Front Width  
Depth  
Note:Aqualified installer should make  
all electrical connections.  
Bottom  
1. Frame in rough opening. Use dimen-  
sions shown in Figure 8 for the rough  
opening.  
3. Install gas piping to fireplace location.  
This installation includes an approved  
flexible gas line (if allowed by local  
codes) after the manual shutoff valve.  
The flexible gas line must be the last  
item installed on the gas piping.  
WARNING: Do not allow any  
combustiblematerialstooverlap  
the firebox front facing.  
If installing in a corner, use dimensions  
shown in Figure 9 for the rough open-  
ing. The height is 26 7/8" which is the  
same as the wall opening above.  
IMPORTANT: Noncombustible materials  
such as brick, tile, etc. may overlap the front  
facing, but should never cover any neces-  
sary openings like louvered slots.  
4. If you have not assembled firebox, fol-  
low instructions on page 4.  
Nails or  
Wood  
Screws  
WARNING: Do not allow non-  
combustible materials to cover  
any necessary openings like lou-  
vered slots.  
10 1/2"  
26 7/8"  
3/4" Off  
The Floor  
Minimum  
WARNING: Never modify or  
cover the louvered slots on the  
front of the firebox.  
26 7/8"  
Figure8-RoughOpeningforInstallingin  
Wall  
WARNING: Use only non-  
combustiblemortaroradhesives  
when overlapping the front fac-  
ing with noncombustible facing  
material.  
Nailing  
Flanges  
36 5/8"  
25 7/8"  
26 7/8"  
51 3/4"  
Figure9-RoughOpeningforInstallingin  
Corner  
Figure 10 - Attaching Fireplace to Wall  
Studs  
Continued  
104060  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
5. Firmly snap brass trim kit on shoulder 11. Install gas line. See Connecting To Gas  
INSTALLATION  
screws. Shoulder screws are located on  
Supply, page 14.  
Continued  
fireplace cabinet (see Figure 12).  
12. Check for leaks. See Checking Gas  
Connections, page 16.  
Mantel Clearances for Built-In  
Installation  
If placing mantel above built-in fireplace,  
youmustmeetminimumclearancebetween  
mantel shelf and top of fireplace opening.  
6. Align brass trim kit for flush fit around  
opening.  
13. Place mantel around fireplace. Be care-  
ful not to damage wall or mantel.  
7. Use two 3" wood screws provided and  
attach fireplace base to wooden base  
(see Figure 12).  
14. Place brass trim kit on the shoulder  
screws located on the side and top of  
the fireplace. Firmly snap the brass trim  
over the shoulder screws on fireplace  
(see Figure 12).  
8. Remove brass trim kit and mantel. Be  
careful not to damage wall or mantel.  
If your installation does not meet the above  
minimum clearances, you must:  
9. Place wood base next to wall at instal-  
lation location.  
• raise the mantel to an acceptable height,  
15. Adjust assembly to remove any gaps.  
Attach remaining two 3" wood screws  
from hardware pack through openings  
inside of fireplace sides into the man-  
tel. The openings are located at top be-  
hind the area for the brass louvers (see  
Figure 13).  
OR  
10. Attach wood base to floor with two 1 3/4"  
black screws provided (see Figure 13). If  
the floor is concrete use anchor method  
(see AttachingWood Base to Solid Floor,  
page 14).  
• remove the mantel.  
OPTIONAL MANTEL  
INSTALLATION  
Note: Refer to instructions provided with  
the mantel for assembly instructions. Refer  
to instructions below for system installa-  
tion. Refer to instructions on page 4 for  
firebox assembly. Blower accessory should  
be installed if it is being used (see Accesso-  
ries, page 27).  
16. Reinstall top brass louvers.  
Shoulder  
Screws  
1. Unscrew four brass screws that attach  
top louver to fireplace. Remove louver  
from fireplace and set aside.  
Hole for 3"  
wood screw  
for attaching  
fireplace to  
mantel  
2. Place fireplace on wood base.  
3. Place mantel around fireplace/base  
assembly.  
4. Assemble brass trim kit. See Assem-  
bling Brass Trim, page 11.  
Mantel Shelf  
Hole for 3"  
10"  
wood screw for  
attaching  
fireplace to  
Note:  
All vertical  
measurements  
are from top of  
fireplace  
8"  
6"  
Assembled  
Brass Trim  
wooden base  
1
2
/2"  
opening to  
bottom of  
Figure 12 - Attaching Brass Trim to Fireplace  
mantel shelf. All  
measurements  
are in inches.  
Side of  
Firebox  
1 3/4" Screw  
Wood  
Base  
Figure 13 - Attaching Wood Base to Floor  
Figure 11 - Minimum Mantel Clearances  
for Built-In Installation  
104060  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
Branch  
Support  
INSTALLING BLOWER  
ACCESSORY GA3400T  
INSTALLATION  
Shoulder  
Screw  
Continued  
Removing Upper Louver  
Assembly  
Assembling Brass Trim (Brass  
trim shipped with mantel)  
Remove  
Screw  
1. Remove packaging from three remain-  
ing pieces of brass trim.  
To install the blower accessory, you must  
first remove the upper louver assembly.  
Valve  
Cover  
Shield  
2. Locate two adjusting plates with set 1. Lift screen off heater.  
screws, and two shims in the hardware  
2. Remove 4 screws from louver assem-  
2
packet.  
bly (see Figure 15). Save these screws.  
3. Align shim under adjusting plate as  
shown in Figure 14.  
3. Pull louver assembly straight out from  
the cabinet. Be careful not to scratch  
the paint. Set louver assembly and  
screws aside.  
4. Slide one end of adjusting plate/shim  
in slot on mitered edge of top brass trim  
(see Figure 14).  
1
Blower Bracket  
Mounting Holes  
5. Slide other end of adjusting plate/shim  
in slot on mitered edge of side brass  
trim (see Figure 14).  
Bottom Louver  
Assembly  
Snap  
Bushings  
6. While firmly holding edges of brass  
trim together, tighten both set screws  
on the adjusting plate with slotted  
screwdriver.  
Figure 16 - Removing Valve Cover Shield  
Installing Blower Assembly  
7. Repeat steps 1 through 6 for other corner.  
8. Set brass assembly aside for later in-  
stallation.  
Note: If you are using a mantel with your  
heater, use the following instructions. If  
your heater is built-in, see For Built-In In-  
stallation on page 13.  
Upper Louver  
Assembly  
Brass Screws  
Top Brass  
Trim  
Set  
1. Install snap bushings found in hardware  
kit into both holes in rear of valve cover  
shield.  
Figure 15 - Removing Upper Louver  
Assembly  
Screws  
Slot  
2. Make sure the wire harness is firmly  
connected to the terminals on the blower  
bracket assembly.  
Removing Valve Cover Shield  
Mitered  
Edge  
1. Open bottom louver assembly by  
swinging the assembly down (see Fig-  
ure 16).  
Shim  
3. Note the wire locations on back of  
AUTO/OFF/ON switch. The terminals  
on back of switch are numbered 1, 2,  
and 3. Carefully remove red wire from  
terminal 1 and blue wire from terminal  
3. Black wire can remain on middle  
terminal 2 (see Figure 17, page 12).  
Side Brass  
Trim  
2. Using short Phillips screwdriver, re-  
move the screw under the center of the  
branch support. Rotate valve cover  
shield clockwise and slide out.  
IMPORTANT: Do not remove shoul-  
der screw on the left side of valve cover  
shield. Slide the valve cover shield off  
of the shoulder screw (see Figure 16).  
Adjusting  
Plate  
Slot  
Figure 14 - Assembling Brass Trim  
Note: If you do not have a short  
Phillips screwdriver, the screen, twigs,  
and branch support must be removed  
so a longer screwdriver may be used.  
See Connecting Fireplace To Gas Sup-  
ply, page 15 and follow step 2.  
Continued  
104060  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
6. Route the wire harness through the 9. Install the switch plate on the valve  
INSTALLATION  
hole in left side of baffle. Pull wire  
harness through lower opening above  
where the valve shield was removed.  
(see Figure 17).  
cover shield with 2 #10 screws provided  
(see Figure 18). Reinstall the valve  
cover shield. Route power cord out of  
the cabinet by inserting it through the  
bushing on the outer casing (see Fig-  
ure 17). Plug fan kit into 120-Volt  
grounded power supply and test opera-  
tion. Note: When switch is in the  
AUTO position, the fan will start after  
the heater has run for a few moments.  
The fan will continue to run for several  
moments after the heater has been  
turned off. When switch is in the ON  
position, the fan will run until turned  
to OFF. Reinstall upper louver assem-  
bly and hood if previously removed,  
(see Figure 15, page 11). Close lower  
louver door.  
Continued  
4. Carefully disconnect green and white  
wires at their insulated connectors.  
7. Insert the 4 wire harness into one of the  
round holes in the rear of the valve cover  
shield and through the rectangular hole  
in the front of shield (see Figure 17).  
5. In top of the heater cabinet, locate the  
four mounting holes on the outer cas-  
ing. Align these four holes with those  
on the blower bracket assembly. Attach  
blower bracket assembly to the outer  
casing with 4 #10 screws provided (see  
Figure 17).  
8. Reconnect red wire to switch position  
3. Reconnect blue wire to switch posi-  
tion 1. Reconnect green and white wires.  
Wiring Routing  
Hole in Baffle  
Blower Bracket  
Assembly  
Screw  
Baffle  
Valve Cover  
Shield  
Wire  
Harness  
Switch  
Plate  
Switch  
Screw  
Power  
Cord  
Figure18-InstallingSwitchPlatetoValve  
Cover Shield  
3
2
1
Red  
Blue  
Switch  
Plate  
Wire  
Harness  
Valve Cover  
Shield  
Box Cover  
Figure 17 - Installing Blower Bracket Assembly  
104060  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
Follow instructions Removing Valve Cover 3. Remove black plastic strain relief and  
INSTALLATION  
Shield (page 11), then  
power cord from switch plate. The  
power cord supplied will not be used in  
built-in installations. Pop in the plastic  
snap bushing found in hardware kit into  
the hole left by supply cord/strain relief.  
Continued  
1. Install a snap bushing found in hard-  
ware kit into one of the holes found on  
rear of valve cover shield. The other  
hole is for a strain relief clamp (not  
For Built-In Installation  
WARNING: A licensed elec-  
trician must connect the wiring  
harness to electrical supply fol-  
lowing all local codes. Electri-  
cian must provide a clamp on  
the box cover to secure the wir-  
ing. Wiring should be routed  
through the bushing in the hole  
on the outer casing of heater.  
supplied) to secure incoming electrical 4. A licensed electrician must follow the  
supply.  
wiring diagram to connect incoming  
electrical supply to fan kit wiring har-  
ness (see Figure 20).  
2. Follow steps 2 through 6 in Installing  
Blower Assembly, pages 11 and 12.  
Also remove black wire from middle 5. Plug power cord to the outlet receptacle  
switch terminal 2.  
(not provided) as shown in figure 19.  
Wind the extra cable in power cord and  
and tie it up with the plastic wire strap  
(see Figure 19). Set the cable bundle  
between the burner bracket and outer  
casing, away from the burner.  
6. Reinstall valve cover shield.  
Blower Bracket  
Assembly  
7. Test to make sure the blower is work-  
ing properly.  
Screw  
8. Reinstall upper louver assembly and  
hood if previously removed, (see Figure  
15, page 11). Close lower louver door.  
Fan Switch  
(Auto/Off/On)  
Auto  
1
2
Off  
3
Thermostat  
Switch  
(N.O.)  
Blue  
On  
Blue  
110/115  
V.A.C.  
Red  
Blower  
Motor  
Black  
Red  
White  
Green  
Switch  
Wire  
Harness  
White  
Green  
Power  
Cord  
Figure 20 - Wiring Diagram For Blower  
Accessory Built-In Installation  
Outlet  
Receptacle  
3
2
1
Extension Cord  
Red  
Use extension cord if needed. The cord must  
have a three-prong, grounding plug and a  
three-hole receptacle. Make sure cord is in  
good shape. It must be heavy enoughto carry  
the current needed. An undersized cord will  
cause a drop in line voltage. This will result  
in loss of power and overheating. Use a No.  
16 AWG cord for lengths less than 50 feet.  
Blue  
Switch Plate  
Plastic Wire  
Strap  
Valve  
Cover  
Shield  
Box Cover  
Wire  
Harness  
Clamp Connector  
(not included)  
Figure 19 - Installing Blower Bracket Assembly  
Continued  
104060  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
Apply pipe joint sealant lightly to male  
INSTALLATION  
CAUTION:Use only new,  
black iron or steel pipe. Inter-  
nally-tinned copper tubing may  
be used in certain areas. Check  
your local codes. Use pipe of  
1/2" or greater diameter to al-  
low proper gas volume to fire-  
place. If pipe is too small, un-  
due loss of pressure will occur.  
threads. This will prevent excess sealant  
from going into pipe. Excess sealant in pipe  
could result in clogged fireplace valves.  
Continued  
Attaching Wood Base to Solid  
Floor  
CAUTION:Usepipejointseal-  
ant that is resistant to liquid pe-  
troleum (LP) gas.  
For attaching base to solid floors (concrete  
or masonry)  
Note: Floor anchors and mounting screws  
are in hardware package. The hardware  
package is provided with fireplace.  
We recommend that you install a sediment  
trap in supply line as shown in Figure 22.  
Locate sediment trap where it is within  
reach for cleaning. Install in piping system  
betweenfuelsupplyandheater.Locatesedi-  
ment trap where trapped matter is not likely  
to freeze. A sediment trap traps moisture  
and contaminants. This keeps them from  
going into fireplace controls. If sediment  
trap is not installed or is installed wrong,  
fireplace may not run properly.  
Installation must include a manual shutoff  
valve, union, and plugged 1/8" NPT tap.  
Locate NPT tap within reach for test gauge  
hook up. NPT tap must be upstream from  
fireplace (see Figure 22).  
1. Drill holes at marked locations using  
5/16" drill bit. For solid floors (con-  
crete or masonry), drill at least 1" deep.  
2. Fold floor anchor as shown in Figure 21.  
3. Insert floor anchor (wings first) into  
hole. Tap anchor flush to floor.  
IMPORTANT: Install main gas valve  
(manual shutoff valve) in an accessible  
location. The main gas valve is for turning  
on or shutting off the gas to the appliance.  
4. Insert mounting screws through base  
and into floor anchors.  
5. Tighten screws until base is firmly fas-  
tened to floor.  
Approved Flexible  
Gas Line  
A.G.A. Design-Certified Manual  
Shutoff Valve With 1/8" NPT Tap*  
Figure 21 - Folding Anchor  
CONNECTING TO GAS  
SUPPLY  
From Gas  
Meter (5"  
W.C. to  
10.5" W.C.  
Pressure)  
WARNING: A qualified ser-  
vice person must connect fire-  
place to gas supply. Follow all  
local codes.  
3" Minimum  
WARNING: Never connect  
fireplace to private (non-utility)  
gas wells. This gas is commonly  
known as wellhead gas.  
Pipe Nipple Cap Tee Joint  
Sediment Trap  
IMPORTANT:Check gas line pressure be-  
fore connecting fireplace to gas line. Gas  
line pressure must be no greater than 14  
inchesofwater.Ifgaslinepressureishigher,  
fireplace regulator damage could occur.  
Figure 22 - Gas Connection  
* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer.  
See Accessories, page 27.  
104060  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
Branch  
Support  
INSTALLATION  
Continued  
Screen  
Shipping  
Screw  
CONNECTING FIREPLACE  
TO GAS SUPPLY  
Installation Items Needed  
• Phillips screwdriver  
Shoulder  
Screw  
• sealant (resistant to propane/LP gas, not  
provided)  
1. Remove fireplace screen. Remove two  
screws that hold fireplace screen in  
place for shipping. These screws are  
located near top of screen. Discard  
screws. Lift fireplace screen up and pull  
out to remove.  
Flexible  
Gas Line  
2. Remove screws that attach branch sup-  
port to fireplace (see Figure 23). Care-  
fully lift up branch support and remove  
from fireplace (see Figure 23).  
Screen  
3. Route flexible gas line (provided by  
installer) from manual shutoff valve  
into fireplace through side or rear ac-  
cess holes in outer casing. Route flex-  
ible gas supply line through fireplace  
access holes in outer casing.  
Figure 23 - Removing Branch Support From Fireplace  
To Fireplace  
Gas  
Regulator  
Gas Connector  
Manual Shutoff Valve  
NOTICE: Most building codes do  
not permit concealed gas con-  
nections. A flexible gas line is  
provided to allow accessibility  
fromthefireplace(seeFigure23).  
The flexible gas supply line con-  
nection to the manual shutoff  
valve should be accessible.  
To Gas  
Supply  
Flexible Gas Line from  
Flexible Gas Line from  
Fireplace Gas Regulator  
Manual Shutoff Valve  
Provided With Fireplace  
Provided By Installer  
4. Apply pipe joint sealant lightly to male  
threads of gas connector attached to  
flexible gas line (see Figure 24). Con-  
nect flexible gas line to flexible gas line  
attached to gas regulator of fireplace  
(see Figure 24).  
Figure 24 - Attaching Flexible Gas Lines Together  
5. Check all gas connections for leaks. See  
Checking Gas Connections, page 16.  
6. Replace branch support back into fire-  
place. Feed flexible gas line into fire-  
place base area while replacing branch  
support. Make sure the entire flexible  
gas line is in fireplace base area. Reat-  
tach branch support to fireplace with  
screws removed in step 2.  
Continued  
104060  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
TestPressuresEqualToorLessThan  
1/2 PSIG  
Pressure Testing Fireplace Gas  
Connections  
1. Open manual shutoff valve (see Figure  
25).  
INSTALLATION  
Continued  
1. Close manual shutoff valve (see Fig-  
ure 25).  
CHECKING GAS  
CONNECTIONS  
2. Pressurize supply piping system by either  
using compressed air or opening main gas  
valve located on or near gas meter.  
2. Open main gas valve located on or near  
gas meter.  
3. Make sure control knob of fireplace is  
in the OFF position.  
WARNING: Test all gas pip-  
ing and connections for leaks  
after installing or servicing. Cor-  
rect all leaks at once.  
3. Check all joints from gas meter to manual  
shutoff valve (see Figure 26).Apply mix-  
ture of liquid soap and water to gas joints.  
Bubbles forming show a leak.  
4. Check all joints from manual shutoff  
valve to thermostat gas valve (see Fig-  
ure 26). Apply mixture of liquid soap  
and water to gas joints. Bubbles form-  
ing show a leak.  
4. Correct all leaks at once.  
WARNING:Neveruseanopen  
flame to check for a leak. Apply a  
mixture of liquid soap and water  
toalljoints.Bubblesformingshow  
a leak. Correct all leaks at once.  
5. Correct all leaks at once.  
Open  
Manual  
Shutoff  
Valve  
6. Light fireplace (see Operating Fire-  
place, pages 17 and 18). Check all other  
internal joints for leaks.  
7. Turn off fireplace (see To Turn Off Gas  
to Appliance, page 18).  
Pressure Testing Gas Supply  
Piping System  
O
Closed  
8. Replace front panel.  
TestPressuresInExcessOf1/2PSIG  
Figure 25 - Manual Shutoff Valve  
1. Disconnect fireplace and its individual  
manual shutoff valve from gas supply  
piping system. Pressures in excess of 1/2  
psig will damage fireplace regulator.  
2. Cap off open end of gas pipe where  
manual shutoff valve was connected.  
Manual  
Shutoff  
Valve  
3. Pressurize supply piping system by either  
using compressed air or opening main gas  
valve located on or near gas meter.  
Gas Meter  
4. Check all joints of gas supply piping  
system. Apply mixture of liquid soap  
and water to gas joints. Bubbles form-  
ing show a leak.  
5. Correct all leaks at once.  
6. Reconnect heater and manual shutoff  
valve to gas supply. Check reconnected  
fittings for leaks.  
Figure 26 - Checking Gas Joints  
104060  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
Note: You may be running this fire-  
place for the first time after hooking  
up to gas supply. If so, the control  
knob may need to be pressed in for  
30 seconds. This will allow air to  
bleed from the gas system.  
• If control knob does not pop up  
when released, contact a qualified  
service person or gas supplier for  
repairs.  
LIGHTING  
INSTRUCTIONS  
OPERATING  
FIREPLACE  
WARNING: You must operate  
this fireplace with the fireplace  
screen in place. Make sure fire-  
place screen is installed before  
running fireplace.  
FOR YOUR SAFETY  
READ BEFORE  
LIGHTING  
WARNING: If you do not fol-  
low these instructions exactly, a  
fireorexplosionmayresultcaus-  
ing property damage, personal  
injury or loss of life.  
NOTICE: During initial operation  
of new fireplace, burning logs  
will give off a paper-burning  
smell. Orange flame will also be  
present. Open window to vent  
smell. Operate fireplace on HI  
position to burn off odor. This  
will only last a few hours.  
6. With control knob pressed in, push  
down and release ignitor button.  
This will light pilot. The pilot is at-  
tached to the front of burner. If  
needed, keep pressing ignitor but-  
ton until pilot lights.  
A. This appliance has a pilot which must  
be lighted by hand. When lighting the  
pilot, follow these instructions exactly.  
Note: If pilot does not stay lit, refer  
to Troubleshooting, pages 20 through  
22. Also contact a qualified service  
person or gas supplier for repairs.  
Until repairs are made, light pilot with  
match. To light pilot with match, see  
Manual Lighting Procedure, page 18.  
B. BEFORE LIGHTING smell all  
around the appliance area for gas. Be  
sure to smell next to the floor because  
some gas is heavier than air and will  
settle on the floor.  
1. STOP! Read the safety information,  
column 1.  
2. Make sure manual shutoff valve is  
fully open.  
3. Turn control knob clockwise  
to the OFF position.  
WHAT TO DO IF YOU SMELL  
GAS  
7. Keep control knob pressed in for 30  
seconds after lighting pilot. After 30  
seconds, release control knob.  
• Do not try to light any appliance.  
• Do not touch any electric switch; do  
not use any phone in your building.  
• Immediately call your gas supplier  
from a neighbor’s phone. Follow  
the gas supplier’s instructions.  
• If you cannot reach your gas sup-  
plier, call the fire department.  
4. Wait five (5) minutes to clear out any  
gas.Then smell for gas, including near  
the floor. If you smell gas, STOP! Fol-  
low “B” in the safety information,  
column 1. If you don’t smell gas, go  
to the next step.  
Note: If pilot goes out, repeat steps  
3 through 7. This fireplace has a  
safety interlock system. Wait one (1)  
minute before lighting pilot again.  
8. Turn control knob counterclockwise  
to desired heating level. The  
main burner should light. Set control  
knob to any heat level between HI  
and LO.  
5. Turn control knob counterclockwise  
the PILOT position. Press  
in control knob for five (5) seconds  
(see Figure 27).  
C. Use only your hand to push in or turn  
the gas control knob. Never use tools.  
If the knob will not push in or turn  
by hand, don’t try to repair it, call a  
qualified service technician or gas  
supplier. Force or attempted repair  
may result in a fire or explosion.  
Control Knob  
CAUTION:Donottrytoadjust  
heating levels by using the  
manual shutoff valve.  
Ignitor Button  
Ignitor Electrode  
D. Do not use this appliance if any part  
has been under water. Immediately call  
a qualified service technician to inspect  
the appliance and to replace any part  
of the control system and any gas con-  
trol which has been under water.  
Thermocouple  
Pilot Burner  
Figure 27 - Control Knob In The OFF  
Position  
Figure 28 - Pilot  
(Actual Pilot May Vary From Illustration)  
Continued  
104060  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
MANUAL LIGHTING  
PROCEDURE  
1. Follow steps 1 through 5 under Light-  
OPERATING  
FIREPLACE  
Continued  
ing Instructions, page 17.  
2. With control knob pressed in, strike  
TO TURN OFF GAS  
TO APPLIANCE  
Shutting Off Fireplace  
match. Hold match to pilot until pi-  
lot lights.  
3. Keep control knob pressed in for 30  
1. Turn control knob clockwise  
seconds after lighting pilot. After 30  
to the OFF position.  
seconds, release control knob. Now  
follow step 8, page 17.  
2. Turn off all electric power to the ap-  
pliance if service is to be performed.  
Shutting Off Burner Only (pilot  
stays lit)  
OPERATING BLOWER  
Turn control knob clockwise  
the PILOT position.  
to  
This blower has three settings: ON, OFF,  
andAUTO.IntheONposition,theblower  
will operate constantly. In the OFF posi-  
tion, the blower will not operate. In the  
AUTOposition,theblowerwillstartwhen  
thethermostatsensesasufficientincrease  
in firebox temperature.  
THERMOSTAT CONTROL  
OPERATION  
The thermostatic control used on this fire-  
place differs from standard thermostats.  
Standard thermostats simply turn on and  
off the burner. The thermostat used on  
this fireplace senses the room tempera-  
ture. The thermostat adjusts the amount  
of gas flow to the burner. This increases or  
decreasestheburnerflameheight.Attimes  
the room may exceed the set temperature.  
If so, the burner will shut off. The burner  
willcyclebackonwhenroomtemperature  
drops below the set temperature.  
Note: Your fireplace and thermostat  
blower will not turn on and off at the  
same time. The fireplace may run for  
several minutes before the blower turns  
on.Aftertheheatermodulatestothepilot  
position, the blower will continue to run.  
The blower will shut off after the firebox  
temperature decreases.  
Note: It is safe to operate fireplace with  
blower turned off. However, the blower  
helps distribute heated air from the  
fireplace.  
The control knob can be set to any heat  
level between HI and LO.  
Auto/Off/On Switch  
Note: The thermostat sensing bulb mea-  
sures the temperature of air near the  
fireplace cabinet. This may not always  
agree with room temperature (depend-  
ing on housing construction, installation  
location, room size, open air tempera-  
tures, etc.). Frequent use of your fire-  
place will let you determine your own  
comfort levels.  
Figure 29 - Auto/Off/On Switch  
104060  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
BURNER FLAME PATTERN  
INSPECTING  
BURNER  
Figure 32 shows a correct burner flame  
pattern.Figure33showsanincorrectburner  
flame pattern. The incorrect burner flame  
patternshowsyellowtippingoftheflame. It  
also shows the flame higher than one inch  
above the log.  
Check pilot flame pattern and burner flame  
pattern often.  
PILOT FLAME PATTERN  
Figure30showsacorrectpilotflamepattern.  
Figure 31 shows an incorrect pilot flame  
pattern.Theincorrectpilotflameisnottouch-  
ing the thermocouple. This will cause the  
thermocouple to cool. When the thermo-  
couple cools, the fireplace will shut down.  
Note: When using the fireplace the first  
time, the flame will be yellow for approxi-  
mately one hour until the log cures.  
WARNING: If yellow tipping  
occurs, your fireplace could pro-  
duce increased levels of carbon  
monoxide. If burner flame pattern  
shows yellow tipping, follow in-  
structions at bottom of this page.  
If pilot flame pattern is incorrect, as shown  
in Figure 31  
• turn fireplace off (see To Turn Off Gas to  
Appliance, page 18)  
• see Troubleshooting, pages 20 through 22  
NOTICE: Do not mistake orange  
flames with yellow tipping. Dirt  
or other fine particles enter the  
fireplace and burn causing brief  
patches of orange flame.  
Thermocouple  
Pilot Burner  
Ifburnerflamepatternisincorrect,asshown  
in Figure 33  
• turn fireplace off (see To Turn Off Gas to  
Appliance, page 18)  
• see Troubleshooting, pages 20 through 22  
Top of Flame About  
One Inch Above Logs  
Figure 30 - Correct Pilot Flame Pattern  
(Actual Pilot May Vary From Illustration)  
Thermocouple  
Pilot Burner  
Figure 32 - Correct Burner Flame Pattern  
Yellow Tipping  
Figure 31 - Incorrect Pilot Flame Pattern  
(Actual Pilot May Vary From Illustration)  
Figure33-IncorrectBurnerFlamePattern  
104060  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
TROUBLESHOOTING  
Note: For additional help, visit DESA  
International’stechnicalservicewebsite  
WARNING: Turn off and un-  
plug fireplace and let cool before  
servicing. Only a qualified ser-  
vice person should service and  
repair fireplace.  
CAUTION: Never use a wire,  
needle, or similar object to clean  
ODS/pilot.ThiscandamageODS/  
pilot unit.  
Note:Alltroubleshootingitemsarelistedin  
order of operation.  
OBSERVED PROBLEM  
POSSIBLE CAUSE  
REMEDY  
When ignitor button is pressed, there is no 1. Ignitor cable pinched or wet  
spark at ODS/pilot  
1. Free ignitor cable if pinched by any  
metal or tubing. Keep ignitor cable dry  
2. Ignitor electrode not connected to igni- 2. Reconnect ignitor cable  
tor cable  
3. Broken ignitor cable  
4. Bad piezo ignitor  
5. Ignitor electrode broken  
6. Ignitor electrode positioned wrong  
3. Replace ignitor cable  
4. Replace piezo ignitor  
5. Replace ignitor  
6. Replace ignitor  
When ignitor button is pressed, there is 1. Gas supply turned off or manual shutoff 1. Turn on gas supply or open manual  
spark at ODS/pilot but no ignition  
valve closed  
shutoff valve  
2. Control knob not in PILOT position  
2. Turn control knob to PILOT position  
3. Control knob not pressed in while in 3. Press in control knob while in PILOT  
PILOT position  
position  
4. Air in gas lines when installed  
4. Continue holding down control knob. Re-  
peat igniting operation until air is removed  
5. Clean ODS/pilot (see Cleaning and  
Maintenance, page 23) or replace ODS/  
pilot assembly  
5. ODS/pilot is clogged  
6. Gas regulator setting is not correct  
6. Replace gas regulator  
ODS/pilot lights but flame goes out when 1. Control knob not fully pressed in  
1. Press in control knob fully  
control knob is released  
2. Control knob not pressed in long enough 2. After ODS/pilot lights, keep control  
knob pressed in 30 seconds  
3. Safety interlock system has been triggered 3. Wait one minute for safety interlock sys-  
tem to reset. Repeat ignition operation  
4. Manual shutoff valve not fully open  
5. Thermocouple connection loose at con- 5. Hand tighten until snug, then tighten 1/4  
trol valve turn more  
4. Fully open manual shut-off valve  
6. Pilot flame not touching thermocouple, 6. A) Contact local natural gas company  
which allows thermocouple to cool,  
causing pilot flame to go out. This prob-  
lem could be caused by one or both of  
the following:  
B) Clean ODS/pilot (see Cleaning and  
Maintenance, page 23) or replace ODS/  
pilot assembly  
A) Low gas pressure  
B) Dirty or partially clogged ODS/pilot  
7. Thermocouple damaged  
8. Control valve damaged  
7. Replace thermocouple  
8. Replace control valve  
104060  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
TROUBLESHOOTING  
Continued  
OBSERVED PROBLEM  
POSSIBLE CAUSE  
REMEDY  
Burner does not light after ODS/pilot is lit  
1. Burner orifice is clogged  
1. Clean burner (see Cleaning and Mainte-  
nance, page 23) or replace burner orifice  
2. Burner orifice diameter is too small  
3. Inlet gas pressure is too low  
2. Replace burner orifice  
3. Contact local natural gas company  
Delayed ignition of burner  
1. Manifold pressure is too low  
2. Burner orifice is clogged  
1. Contact local natural gas company  
2. Clean burner (see Cleaning and Mainte-  
nance, page 23) or replace burner orifice  
Burner backfiring during combustion  
1. Burner orifice is clogged or damaged  
1. Clean burner (see Cleaning and Mainte-  
nance, page 23) or replace burner orifice  
2. Replace burner pressure  
2. Burner damaged  
3. Low inlet gas pressure  
4. Gas regulator defective  
3. Contact local natural gas company  
4. Replace gas regulator  
Yellow flame during burner combustion  
1. Not enough air  
1. Check burner for dirt and debris. If  
found, clean burner (see Cleaning and  
Maintenance, page 23)  
2. Gas regulator defective  
2. Replace gas regulator  
Slight smoke or odor during initial operation 1. Residues from manufacturing processes 1. Problem will stop after a few hours of  
operation  
Fireplace produces a whistling noise when 1. Turning control knob to HI position 1. Turn control knob to LO position and  
burner is lit  
when burner is cold  
2. Air in gas line  
let warm up for a minute  
2. Operate burner until air is removed from  
line. Have gas line checked by local  
natural gas company  
3. Air passageways on fireplace blocked  
3. Observe minimum installation clear-  
ances (see pages 8 through 10)  
4. Dirty or partially clogged burner orifice 4. Clean burner (see Cleaning and Mainte-  
nance, page 23) or replace burner orifice  
Whitepowderresidueformingwithinburner 1. When heated, vapors from furniture pol- 1. Turn heater off when using furniture  
box or on adjacent walls or furniture  
ish, wax, carpet cleaners, etc. turn into  
white powder residue  
polish, wax, carpet cleaners, or similar  
products  
Continued  
104060  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
TROUBLESHOOTING  
Continued  
WARNING: If you smell gas  
• Shut off gas supply.  
• Do not try to light any appliance.  
• Do not touch any electrical switch; do not use any phone in your  
building.  
• Immediatelycallyourgassupplierfromaneighbor’sphone. Followthe  
gas supplier’s instructions.  
• If you cannot reach your gas supplier, call the fire department.  
IMPORTANT:Operatingfireplacewhereimpuritiesinairexistmaycreateodors.Cleaning  
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,  
etc., create fumes. These fumes may mix with combustion air and create odors.  
OBSERVED PROBLEM  
POSSIBLE CAUSE  
REMEDY  
Fireplace produces a clicking/ticking noise 1. Metal expanding while heating or con- 1. This is common with most fireplaces. If  
just after burner is lit or shut off  
tracting while cooling  
noise is excessive, contact qualified ser-  
vice person  
Fireplace produces unwanted odors  
1. Fireplace burning vapors from paint, hair 1. Ventilate room. Stop using odor caus-  
spray, glues, etc. (See IMPORTANT  
ing products while fireplace is running  
statement above)  
2. Gas leak. SeeWarning statement at 2. Locate and correct all leaks (see Check-  
top of page  
ing Gas Connections, page 16)  
Fireplace shuts off in use (ODS operates)  
1. Not enough fresh air is available  
2. Low line pressure  
3. ODS/pilot is partially clogged  
1. Open window and/or door for ventilation  
2. Contact local natural gas company  
3. Clean ODS/pilot (see Cleaning and  
Maintenance, page 23)  
Gas odor even when control knob is in OFF 1. Gas leak. SeeWarning statement at 1. Locate and correct all leaks (see Check-  
position  
top of page  
ing Gas Connections, page 16)  
2. Control valve defective  
2. Replace control valve  
Gas odor during combustion  
1. Foreign matter between control valve 1. Take apart gas tubing and remove for-  
and burner eign matter  
2. Gas leak. SeeWarning statement at 2. Locate and correct all leaks (see Check-  
top of page  
ing Gas Connections, page 16)  
Moisture/condensationnoticedonwindows 1. Not enough combustion/ventilation air  
1. Refer to Air for Combustion and Venti-  
lation requirements (page 5)  
104060  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
3. Blow air through the ports/slots and  
CABINET  
CLEANING AND  
MAINTENANCE  
holes in the burner.  
Air Passageways  
4. Check the injector holder located at the  
end of the burner tube again. Remove • Use a vacuum cleaner or pressurized air  
any large particles of dust, dirt, lint, or  
pet hairs with a soft cloth or vacuum  
cleaner nozzle.  
to clean.  
WARNING: Turn off fireplace  
and let cool before cleaning.  
Exterior  
• Use a soft cloth dampened with a mild  
soap and water mixture. Wipe the cabi-  
net to remove dust.  
5. Blow air into the primary air holes on  
the injector holder.  
CAUTION:Youmustkeepcon-  
trol areas, burner, and circulating  
air passageways of fireplace  
clean. Inspect these areas of fire-  
place before each use. Have fire-  
place inspected yearly by a quali-  
fiedserviceperson.Fireplacemay  
need more frequent cleaning due  
to excessive lint from carpeting,  
pet hair, etc.  
6. In case any large clumps of dust have  
now been pushed into the burner repeat  
steps 3 and 4.  
Clean the pilot assembly also. A yellow tip  
on the pilot flame indicates dust and dirt in  
the pilot assembly. There is a small pilot air  
inlet hole about two inches from where the  
pilot flame comes out of the pilot assembly  
(see Figure 35). With the unit off, lightly  
blow air through the air inlet hole. You may  
blowthroughadrinkingstrawifcompressed  
air is not available.  
CLEANING BURNER  
INJECTOR HOLDER AND  
PILOT AIR INLET HOLE  
Injector Holder  
The primary air inlet holes allow the proper  
amount of air to mix with the gas. This  
provides a clean burning flame. Keep these  
holesclearofdust, dirt, andlint. Cleanthese  
air inlet holes prior to each heating season.  
Blocked air holes will create soot. We rec-  
ommend that you clean the unit every 2,500  
hours of operation or every three months.  
Ports/Slots  
Burner  
Tube  
Primary Air Inlet  
Holes  
Wealsorecommendthatyoukeeptheburner  
tube and pilot assembly clean and free of  
dustanddirt.Tocleanthesepartswerecom-  
mend using compressed air no greater than  
30 PSI. Your local computer store, hard-  
ware store, or home center may carry com-  
pressed air in a can. You can use a vacuum  
cleaner in the blow position. If using com-  
pressed air in a can, please follow the direc-  
tions on the can. If you don't follow direc-  
tions on the can, you coulddamage the pilot  
assembly.  
Figure 34 - Injector Holder On Outlet  
Burner Tube  
Pilot Air Inlet  
Hole  
1. Shut off the unit, including the pilot.  
Allow the unit to cool for at least thirty  
minutes.  
Pilot Assembly  
Figure 35 - Pilot Inlet Air Hole  
2. Inspect burner, pilot, and primary air  
inlet holes on injector holder for dust  
and dirt (see Figure 34).  
104060  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
ILLUSTRATED  
3
PARTS  
17  
1
BREAKDOWN  
9
VMH26TNA  
30  
7
4
8
27  
43  
3
10  
35-1  
7
43  
4
2
33  
11  
14  
25  
24  
29  
20  
12-1  
23  
43  
13  
35-2  
37  
14  
32  
40  
34  
19  
5
38  
25  
6
12  
28  
24  
15  
18  
26  
39  
36  
22  
42  
12-1  
12-2  
21  
41  
16  
31  
104060  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
PARTS LIST  
VMH26TNA  
KEY NO.  
PART NO.  
DESCRIPTION  
QTY.  
1
2
3
4
5
6
7
8
102633-02CK  
102624-02  
099230-02  
098304-01  
103447-02  
103209-03  
102635-02CK  
101629-02  
103209-01  
101712-04  
102638-01  
103042-01  
098514-01  
098594-01  
102460-01CJ  
099211-01  
103963-01  
102834-01  
100587-01  
098303-02  
104335-01CK  
102649-01CJ  
099415-10  
102875-01  
101381-01  
099387-11  
098271-06  
103845-12  
102458-01CK  
098249-01  
098522-14  
102639-01  
101628-01  
102869-01  
102731-01  
103295-01CJ  
103058-01  
104058-01  
104058-02  
104313-01  
104313-02  
M10908-2  
Outer Casing Top  
Outer Casing  
Shoulder Screw  
Screw, #10 x 3/8"  
Burner  
Louvered Door  
Left and Right Side Front  
Bushing  
Brass Top Louver  
Firebox Hood  
Firebox Top  
ODS/Pilot Assembly  
Thermocouple  
Ignitor Electrode  
Firebox Wrapper  
Control Bracket Screw  
Inlet Tube  
1
1
12  
14  
1
1
2
1
1
1
1
1
1
1
1
2
1
1
4
2
1
1
1
1
1
1
1
1
1
6
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
28  
This list contains replaceable parts used in  
your fireplace. When ordering parts, follow  
the instructions listed under Replacement  
Parts on page 26 of this manual.  
9
10  
11  
12  
12-1  
12-2  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
35-1  
35-2  
36  
37  
38  
39  
40  
41  
42  
43  
Burner Tube  
Brass Screw, #6 x 3/8  
Regulator Screw  
Outer Shell Base  
Branch Support  
Gas Regulator  
Regulator Bracket  
Valve Cover and Piezo  
Pilot Tube  
Ignitor Cable  
Injector  
Front, Top Middle  
Nut, M5  
Gas Valve  
Baffle  
Flexible Connector  
Control Bracket  
Control Shield  
Screen Assembly  
Log Set Assembly  
Branch Service Kit  
Back Log Service Kit  
Right Hinge  
Left Hinge  
Hinge Screws  
Burner Support, Right  
Burner Support, Left  
3/8" NPT x 3/8" Flare Brass Fitting  
Bushing  
102645-02  
102645-03  
097809-03  
101629-01  
M11084-26  
Hex Head Screw, #10 x 3/8"  
PARTS AVAILABLE — NOT SHOWN  
104319-02  
Information Video  
Lighting Instructions Plate  
Warning Plate  
1
1
1
1
101054-01  
100563-01  
103470-01  
Hardware Package  
104060  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
VMH26TNA  
COMPACT CLASSIC HEARTH FIREPLACE  
SPECIFICATIONS  
REPLACEMENT  
PARTS  
Btu (Variable)  
Type Gas  
14,000/26,000  
Natural Only  
Piezo  
Note: Use only original replacement parts.  
Thiswillprotectyourwarrantycoveragefor  
parts replaced under warranty.  
Ignition  
Pressure Regulator Setting  
3" W.C.  
Inlet Gas Pressure (in. of water) *  
Maximum  
PARTS UNDER WARRANTY  
10.5"  
5"  
Contact authorized dealers of this product.  
If they can’t supply original replacement  
part(s) call DESA International’s Technical  
Service Department at 1-800-323-5190 for  
referral information.  
Minimum  
Dimensions, Inches (H x W x D)  
Fireplace (including hood and screws)  
Carton  
25 7/8 x 26 13/16 x 9 3/8  
32 5/8 x 27 3/16 x 11 5/8  
Weight, pounds  
Fireplace  
When calling DESA International, have  
ready  
44 1/2 lbs.  
48 lbs.  
Shipping  
• your name  
* For purposes of input adjustment  
• your address  
• model and serial numbers of your fireplace  
• how fireplace was malfunctioning  
TECHNICAL  
SERVICE  
SERVICE HINTS  
• type of gas used (propane/LP or natural  
gas)  
When Gas Pressure Is Too Low  
• purchase date  
You may have further questions about in-  
stallation, operation, or troubleshooting.  
• pilot will not stay lit  
• burner will have delayed ignition  
• fireplace will not produce specified heat  
Usually, we will ask you to return the defec-  
tive part to the factory.  
If so, contact DESA International’s Techni-  
cal Service Department at 1-800-323-5190.  
PARTS NOT UNDER  
WARRANTY  
When Gas Quality Is Bad  
• pilot will not stay lit  
You can also visit DESA International’s  
technical services web site at  
• burner will produce flames and soot  
• fireplace will backfire when lit  
Contact authorized dealers of this product.  
If they can’t supply original replacement  
part(s) call DESA International’s Parts De-  
partment at 1-800-972-7879 for referral in-  
formation.  
Youmayfeelyourgaspressureistoolowor  
gas quality is bad. If so, contact your local  
natural gas supplier.  
When calling DESA International, have  
ready  
• model number of your fireplace  
• the replacement part number  
104060  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER’S MANUAL  
ACCESSORIES  
CABINET MANTEL WITH  
BUILT-IN HEARTH BASE  
Unfinished - GM921U  
Purchase these fireplace accessories from  
your local dealer. If they cannot supply these  
accessories call DESA International’s Sales  
Department at 1-800-458-2472 for referral  
information. You can also write to the ad-  
dress listed on the back page of this manual.  
Finished - GM920F  
For use with fireplace. A hardwood mantel  
and hearth base offers compact styling and  
completes the fireplace look. Available in a  
walnut finished or an unfinished hardwood,  
ready to stain or paint. Complete assembly  
instructionsincluded.Three-sidedbrasstrim  
kit included.  
MANUAL SHUTOFF VALVE  
GA5010  
Manual shutoff valve with 1/8" NPT tap.  
CABINET MANTEL WITH  
BUILT-IN HEARTH BASE  
Unfinished - GM923U  
Finished - GM922F  
For use with fireplace. A hardwood mantel  
and hearth base offers compact styling and  
completes the fireplace look. Available in a  
stained or an unfinished (ready to stain or  
paint) Oak Veneer over hardwood. Com-  
pleteassemblyinstructionsincluded.Three-  
sided brass trim kit included.  
BRASS TRIM KIT - GA6094  
Optional three-sided brass trim kit for cus-  
tom and recessed installations (when unit is  
on the floor). Provides a finished appear-  
ance by covering rough edges of wall open-  
ing. Included with all mantels.  
BRASS TRIM KIT - GA6095  
Optional four-sided brasstrim kit forrecessed  
built-ininstallations(whenunitisraisedoffof  
the floor. Provides a finished appearance by  
covering rough edges of wall opening.  
CORNER MANTEL WITH  
BUILT-IN HEARTH BASE  
Unfinished - GM721U  
Finished - GM720F  
Forusewithfireplace. Space-savingmantel  
andhearthbasecornerdesignfeaturesclean,  
classic lines. Available in a walnut finish or  
an unfinished hardwood, ready to stain or  
paint. Complete assembly instructions in-  
cluded. Three-sided brass trim kit included.  
THERMOSTATICALLY -  
CONTROLLED BLOWER KIT  
GA3400T  
Providesbetterheatdistribution.Makesfire-  
place more efficient. Automatically turns  
off and on as needed.  
104060  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY INFORMATION  
KEEP THIS WARRANTY  
Model  
Serial No.  
Date Purchased  
Always specify model and serial numbers when communicating with the factory.  
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written  
warranty. We make no other warranty, expressed or implied.  
LIMITED WARRANTY  
VENT-FREE NATURAL GAS COMPACT CLASSIC HEARTH® FIREPLACE  
DESA International warrants this product to be free from defects in materials and components for four (4) years and five (5) years  
on stainless steel burners from the date of first purchase, provided that the product has been properly installed, operated and  
maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check  
must be presented.  
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this  
fireplace to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty  
part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory  
replacement parts. Failure to use original factory replacement parts voids this warranty. The fireplace MUST be installed by a  
qualified installer in accordance with all local codes and instructions furnished with the unit.  
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become  
damagedasaresultofmisuse, accidents, lackofpropermaintenanceordefectscausedbyimproperinstallation. Travel, diagnosticcost,  
labor, transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner.  
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE  
PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND  
LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTA-  
BILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS AND FIVE (5)  
YEARS ON STAINLESS STEEL BURNERS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S  
LIABILITYISHEREBYLIMITEDTOTHEPURCHASEPRICEOFTHEPRODUCTANDDESAINTERNATIONALSHALL  
NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSE-  
QUENTIAL DAMAGES.  
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential  
damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.  
For information about this warranty write:  
INTERNATIONAL  
2701 Industrial Drive  
P.O. Box 90004  
Bowling Green, KY 42102-9004  
104060-01  
104060 01  
REV. D  
01/00  
NOT A UPC  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Compaq Personal Computer AP230 User Manual
Crosley Clothes Dryer W10151585B User Manual
Dell Server C5220 User Manual
Delta Electronics Power Supply SIL104R User Manual
Dual Stereo System MXDMA65 User Manual
Ducane Air Conditioner 2SA13B User Manual
Earthquake Sound Speaker F40 User Manual
EVGA Computer Hardware 50081 14 User Manual
Furman Sound Power Supply PL PRO E II User Manual
Gefen Switch Gefen User Manual