VENT-FREE NATURAL GAS
COMPACT CLASSIC HEARTH® FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
VMH26TNA
14,000 to 26,000 Btu/Hr
with Thermostat
Shown with Optional
Cabinet Mantel/Hearth
Base Accessory
WARNING: Improper installa-
WARNING: If the information in this manual
tion,adjustment,alteration,ser-
is not followed exactly, a fire or explosion
vice,ormaintenancecancause
may result causing property damage, per-
sonal injury, or loss of life.
injury or property damage. Re-
fer to this manual for correct
—
Do not store or use gasoline or other
installationandoperationalpro-
cedures. For assistance or ad-
ditional information consult a
qualified installer, service
agency, or the gas supplier.
flammable vapors and liquids in the vicinity
of this or any other appliance.
—
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas
supplier’s instructions.
WARNING:Thisisanunvented
gas-fired heater. It uses air
(oxygen) from the room in
whichitisinstalled.Provisions
for adequate combustion and
ventilation air must be pro-
vided.RefertoAirforCombus-
tion and Ventilation section on
page 5 of this manual.
• If you cannot reach your gas supplier, call
the fire department.
—
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
PRODUCT
PRODUCT
IDENTIFICATION
FEATURES
Fireplace
Cabinet
SAFETY PILOT
This fireplace has a pilot with an Oxygen
Depletion Sensor Shutoff System (ODS).
The ODS/pilot is a required feature for vent-
freeroomfireplaces.TheODS/pilotshutsoff
the fireplace if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This sys-
tem requires no matches, batteries, or other
sources to light fireplace.
Screen
THERMOSTATIC HEAT
CONTROL
This fireplace has a thermostat sensing bulb
and a control valve. The thermostat will
automatically modulate the heat output to
maintain a consistent room temperature.
This results in greater fireplace comfort.
This can also result in lower gas bill.
Logs
Control Knob
Ignitor Button
Figure 1 - Vent-Free Natural Gas Compact Fireplace
LOCAL CODES
UNPACKING
1. Remove log box and fireplace from
carton. The hood is not attached.
Install and use fireplace with care. Follow all
localcodes.Intheabsenceoflocalcodes,use
the latest edition of The National Fuel Gas
CodeANSZ223.1,alsoknownasNFPA54*.
2. Remove all protective packaging ap-
plied to fireplace for shipment.
3. Make sure your fireplace includes one
hardware packet.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
4. Check fireplace for any shipping
damage. If fireplace is damaged,
promptly inform dealer where you
bought fireplace.
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
104060
3
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
Screen
ASSEMBLY
Shipping
Back Log
Screw
Shoulder
WARNING: Always have
branch support and screen in
place before operating fireplace.
Thispreventsexcessivetempera-
tures on fireplace surfaces.
Screw
Burner
Support
WARNING: Failure to position
thepartsinaccordancewiththese
diagrams or failure to use only
parts specifically approved with
this fireplace may result in prop-
erty damage or personal injury
Screw
ASSEMBLING FIREPLACE
Tools Required:
• Phillips screwdriver
• 5/16" hex wrench
• slotted screwdriver
Branch
Support
Installing Log
1. Remove back log, branch, and hood from
log box. Discard protective packaging.
Screw
Screen
Branch
2. Remove two shipping screws above
screen (see Figure 2).
Figure 2 - Assembling Fireplace
3. Lift screen up and pull out to remove.
Assembling Hood
4. An optional blower is available. See
Accessories, page 27. Install optional
blower now. Follow installation in-
structions provided with blower.
1. Locate four #10-3/8" black phillips
sheet metal screws from the hardware
packet.
5. Gently place back log on burner sup-
port (see Figure 2). The log should fit
flat against top of burner support. Place
two #10 one-inch-long screws through
burner support into the log and tighten.
2. Slip top of hood between middle rail and
top of firebox wrapper (see Figure 3).
3. Attach four #10-3/8" hood screws as
shown in Figure 3.
Upper Louver
Assembly
6. Place branch on branch support (see
Figure 2). Do not allow branch to con-
tact flame. If flame contacts branch,
soot will be created.
Middle
Rail
Firebox
Wrapper
7. Reattach screen by placing the notches
in the screen frame over the shoulder
screws and pushing down.
Hood
#10-3/8"
Screws
Figure 3 - Assembling Hood
104060
4
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Confined and Unconfined Space
PROVIDING ADEQUATE
VENTILATION
AIR FOR
The National Fuel Gas Code (ANS Z223.1,
1992 Section 5.3) defines a confined space
as a space whose volume is less than 50
cubic feet per 1,000 Btu per hour (4.8 m3 per
kw) of the aggregate input rating of all
appliances installed in that space and an
unconfining space as a space whose volume
is not less than 50 cubic feet per 1,000 Btu
per hour (4.8 m3 per kw) of the aggregate
inputratingofallappliancesinstalledinthat
space. Rooms communicating directly with
the space in which the appliances are in-
stalled*, through openings not furnished
with doors, are considered a part of the
unconfined space.
COMBUSTION AND
VENTILATION
The following are excerpts from National
Fuel Gas Code. NFPA 54/ANS Z223.1, Sec-
tion5.3, AirforCombustionandVentilation.
WARNING: This heater shall
notbeinstalledinaconfinedspace
or unusually tight construction
unless provisions are provided
foradequatecombustionandven-
tilation air. Read the following in-
structions to insure proper fresh
air for this and other fuel-burning
appliances in your home.
All spaces in homes fall into one of the three
following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 5 through 7 will
help you classify your space and provide
adequate ventilation.
Today’s homes are built more energy effi-
cient than ever. New materials, increased
insulation, and new construction methods
helpreduceheatlossinhomes.Homeowners
weather strip and caulk around windows and
doorstokeepthecoldairoutandthewarmair
in. During heating months, home owners
want their homes as airtight as possible.
Unusually Tight Construction
This heater shall not be installed in a con-
fined space or unusually tight construction
unless provisions are provided for adequate
combustion and ventilation air.
The air that leaks around doors and win-
dows may provide enough fresh air for
combustion and ventilation. However, in
buildings of unusually tight construction,
you must provide additional fresh air.
* Adjoining rooms are communicating only
iftherearedoorlesspassagewaysorventila-
tion grills between them.
Unusually tight construction is de-
fined as construction where:
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper com-
bustion and ventilation.
a. walls and ceilings exposed to the
outside atmosphere have a con-
tinuous water vapor retarder with
a rating of one perm (6 x 10-11 kg
per pa-sec-m2) or less with open-
ings gasketed or sealed and
Exhaustfans, fireplaces, clothesdryers, and
fuel burning appliances draw air from the
house to operate. You must provide ad-
equate fresh air for these appliances. This
will insure proper venting of vented fuel-
burning appliances.
b. weather stripping has been
added on openable windows and
doors and
c. caulking or sealants are applied
to areas such as joints around
window and door frames, be-
tween sole plates and floors, be-
tween wall-ceiling joints, be-
tween wall panels, at penetra-
tions for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three
criteria above, you must provide ad-
ditional fresh air. See Ventilation Air
From Outdoors, page 7.
If your home does not meet all of the
three criteria above, proceed to De-
termining Fresh-Air Flow For Fire-
place Location, page 6.
Continued
104060
5
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
AIR FOR
COMBUSTION AND
VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION
Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height = _________________cu. ft. (volume of space)
Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) =2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of
the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
_____________________(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft = 51.2 or 51,200 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free fireplace
Gas water heater*
Gas furnace
Vented gas heater
Gas fireplace logs
__________________Btu/Hr
__________________Btu/Hr
__________________Btu/Hr
__________________Btu/Hr
__________________Btu/Hr
Example:
30,000
26,000
56,000
Gas water heater
Vent-free fireplace +
Btu/Hr
Btu/Hr
Btu/Hr
Total
=
Other gas appliances* + __________________Btu/Hr
Total = __________________Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_________________ Btu/Hr (maximum the space can support)
_________________ Btu/Hr (actual amount of Btu/Hr used)
Example: 51,200 Btu/Hr (maximum the space can support)
56,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confinedspace because the actual Btu/Hr used is more than the maximum Btu/Hr the space cansupport.
You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-
ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7.
C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
WARNING:If the area in which the heater may be operated is smaller than that defined as an unconfined space
or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of
the methods described in the National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3 or applicable local codes.
104060
6
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
AIR FOR
COMBUSTION AND
VENTILATION
12"
Continued
VENTILATION AIR
Ventilation Air From Inside
Building
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilation
Grills
Or
Thisfreshairwouldcomefromanadjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must pro-
vide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 4). You can also
remove door into adjoining room (see op-
tion 3, Figure 4). Follow the National Fuel
Gas Code NFPA 54/ANS Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
into Adjoining
Room,
Option 1
Remove
Door into
Adjoining
Room,
Option 3
12"
WARNING: Rework work-
sheet, adding the space of the
adjoining unconfined space. The
combined spaces must have
enough fresh air to supply all
appliances in both spaces.
Figure 4 - Ventilation Air from Inside Building Shown with Optional Mantel
Ventilation Air From Outdoors
Ventilated
Provide extra fresh air by using ventilation
grills or ducts. You must provide two per-
manent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
orspacesopentotheoutdoors. Thesespaces
include attics and crawl spaces. Follow the
National Fuel Gas Code NFPA 54/ANS
Z223.1, Section5.3, AirforCombustionand
Ventilation for required size of ventilation
grills or ducts.
Outlet
Attic
Air
Outlet
Air
To Attic
To
Crawl
Space
IMPORTANT: Do not provide openings for
inlet or outlet air into attic if attic has a
thermostat-controlledpowervent. Heatedair
enteringtheatticwillactivatethepowervent.
Inlet
Air
Ventilated
Inlet Air
Crawl Space
Figure 5 - Ventilation Air from Outdoors Shown with Optional Mantel
104060
7
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
Note: Your Vanguard fireplace is designed
INSTALLATION
CAUTION: If you install the
to be used in zero clearance installations.
Wall or framing material can be placed
directly against any exterior surface on the
rear, sides, or top of your fireplace, except
where stand-off spacers are integrally at-
tached. If standoff spacers are attached to
your fireplace, these spacers can be placed
directly against wall or framing materials.
fireplace in a home garage
• fireplace pilot and burner must
beatleast18inchesabovefloor.
• locate fireplace where moving
vehicle will not hit it.
NOTICE: This heater is intended
foruseassupplementalheat.Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’scirculatingblowerwhile
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
For convenience and efficiency, install
fireplace
Use the dimensions shown for rough open-
ings to create the easiest installation (see
Built-In Fireplace Installation, page 9).
• where there is easy access for operation,
inspection, and service.
• in coldest part of room.
An optional blower kit is available from
your dealer. See Accessories, page 27. If
planningtouseblower,locatefireplacenear
an electrical outlet.
CHECK GAS TYPE
Use only natural gas. If your gas supply is
not natural gas, do not install fireplace. Call
dealerwhereyouboughtfireplaceforproper
type fireplace.
WARNING: A qualified ser-
vicepersonmustinstallfireplace.
Follow all local codes.
CEILING
INSTALLATION ITEMS
36"
Minimum
Before installing fireplace, make sure you
have the items listed below.
WARNING: Never install the
fireplace
6"
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve *
• test gauge connection *
• ground joint union
• sediment trap
Minimum
From
• in a bedroom or a bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objectsarelessthan36inches
from the front, top, or sides of
the fireplace
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
Sides Of
Fireplace
Left
Side
Right
Side
• tee joint
• pipe wrench
* AnA.G.A.design-certifiedmanualshutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See
Accessories, page 27.
FLOOR
Figure6-MountingClearancesAsViewed
From Front of Fireplace Shown Built In
The Wall
CAUTION: This fireplace cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to fireplace. Installing
fireplace next to vinyl or cloth
wall coverings or operating fire-
place where impurities (such as
tobacco smoke, aromatic
candles, cleaning fluids, oil or
kerosene lamps, etc.) in the air
exist, may discolor walls.
CEILING
Note:Ifdesired,purchaseafour-sidedbrass
trim kit for built-in installations. See Acces-
sories, page 27.
Top Of
Mantel Can
36"
Be Flush
Minimum
With Wall
LOCATING FIREPLACE
WARNING:Maintainthemini-
mum clearances shown in Fig-
ures 6 and 7. If you can, provide
greater clearances from floor,
ceiling, and joining wall.
Right
Side
IMPORTANT:Vent-freefireplacesaddmois-
ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilationairmaycausemildewtoformfrom
too much moisture. See Air for Combustion
and Ventilation, pages 5 through 7.
Left
Side
You can recess firebox into the wall. You
can also position fireplace in the optional
cabinet or corner mantels. IMPORTANT:
Only use optional cabinet or corner mantels
specified in this manual. Purchase the op-
tional mantel from your dealer (see Acces-
sories, page 27).
Figure7-MountingClearancesAsViewed
From Front of Fireplace Shown with
Optional Mantel
104060
8
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
2. If installing GA3400(T) blower acces- 5. Carefully set fireplace in front of rough
INSTALLATION
sory, do so at this time. Follow instruc-
opening with back of fireplace inside
Continued
tions included with blower accessory.
wall opening.
BUILT-IN FIREPLACE
INSTALLATION
Note: If not installing blower acces- 6. Attach flexible gas line to fireplace gas
sory, you may wish to run electrical
wiring to your fireplace for future
blower installation (see Accessories,
page 27) Use only approved three-wire
electrical wiring.
regulator. See Connecting Fireplace to
Gas Supply, page 15.
Built-ininstallationofthisfireplaceinvolves
installing fireplace into a framed-in enclo-
sure. This makes the front of fireplace flush
with wall. An optional brass trim kit acces-
sory is available (see Accessories, page 27).
Brasstrimwillextendpastsidesoffireplace
approximately 1/2 inch. This will cover the
rough edges of the wall opening. If install-
ingabuilt-inmantelabovethefireplaceyou
must follow the clearances shown in Figure
11, page 10. Follow the instructions below
to install the fireplace in this manner.
7. Bend four nailing flanges on outer cas-
ing with pliers (see Figure 10).
8. Attach fireplace to wall studs using
nails or wood screws through holes in
nailing flange.
WARNING: If pre-wiring, do
not connect wiring to any electri-
cal source at this time.
9. Check all gas connections for leaks. See
Checking Gas Connections, page 16.
Install fireplace electrical outlet
and connect wiring to outlet be-
fore connecting to electrical
source. The fireplace electrical
outlet is included with the
GA3400(T) blower accessory.
10. If using optional brass trim kit, install
the trim after final finishing and/or
painting of wall. See instructions in-
cluded with brass trim accessory for at-
taching brass trim.
Actual Framing
Height
26"
26 3/4"
9 1/2"
3/4"
26 7/8"
26 7/8"
10 1/2"
3/4"
IMPORTANT: When finishing your fire-
box, combustible materials such as wall
board, gypsum board, sheet rock, drywall,
plywood, etc. may be butted up next to the
sides and top of the firebox. Combustible
materials should never overlap the firebox
front facing.
Only use the fireplace electrical
outlet supplied with the
GA3400(T) blower accessory.
Front Width
Depth
Note:Aqualified installer should make
all electrical connections.
Bottom
1. Frame in rough opening. Use dimen-
sions shown in Figure 8 for the rough
opening.
3. Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the manual shutoff valve.
The flexible gas line must be the last
item installed on the gas piping.
WARNING: Do not allow any
combustiblematerialstooverlap
the firebox front facing.
If installing in a corner, use dimensions
shown in Figure 9 for the rough open-
ing. The height is 26 7/8" which is the
same as the wall opening above.
IMPORTANT: Noncombustible materials
such as brick, tile, etc. may overlap the front
facing, but should never cover any neces-
sary openings like louvered slots.
4. If you have not assembled firebox, fol-
low instructions on page 4.
Nails or
Wood
Screws
WARNING: Do not allow non-
combustible materials to cover
any necessary openings like lou-
vered slots.
10 1/2"
26 7/8"
3/4" Off
The Floor
Minimum
WARNING: Never modify or
cover the louvered slots on the
front of the firebox.
26 7/8"
Figure8-RoughOpeningforInstallingin
Wall
WARNING: Use only non-
combustiblemortaroradhesives
when overlapping the front fac-
ing with noncombustible facing
material.
Nailing
Flanges
36 5/8"
25 7/8"
26 7/8"
51 3/4"
Figure9-RoughOpeningforInstallingin
Corner
Figure 10 - Attaching Fireplace to Wall
Studs
Continued
104060
9
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
5. Firmly snap brass trim kit on shoulder 11. Install gas line. See Connecting To Gas
INSTALLATION
screws. Shoulder screws are located on
Supply, page 14.
Continued
fireplace cabinet (see Figure 12).
12. Check for leaks. See Checking Gas
Connections, page 16.
Mantel Clearances for Built-In
Installation
If placing mantel above built-in fireplace,
youmustmeetminimumclearancebetween
mantel shelf and top of fireplace opening.
6. Align brass trim kit for flush fit around
opening.
13. Place mantel around fireplace. Be care-
ful not to damage wall or mantel.
7. Use two 3" wood screws provided and
attach fireplace base to wooden base
(see Figure 12).
14. Place brass trim kit on the shoulder
screws located on the side and top of
the fireplace. Firmly snap the brass trim
over the shoulder screws on fireplace
(see Figure 12).
8. Remove brass trim kit and mantel. Be
careful not to damage wall or mantel.
If your installation does not meet the above
minimum clearances, you must:
9. Place wood base next to wall at instal-
lation location.
• raise the mantel to an acceptable height,
15. Adjust assembly to remove any gaps.
Attach remaining two 3" wood screws
from hardware pack through openings
inside of fireplace sides into the man-
tel. The openings are located at top be-
hind the area for the brass louvers (see
Figure 13).
OR
10. Attach wood base to floor with two 1 3/4"
black screws provided (see Figure 13). If
the floor is concrete use anchor method
(see AttachingWood Base to Solid Floor,
page 14).
• remove the mantel.
OPTIONAL MANTEL
INSTALLATION
Note: Refer to instructions provided with
the mantel for assembly instructions. Refer
to instructions below for system installa-
tion. Refer to instructions on page 4 for
firebox assembly. Blower accessory should
be installed if it is being used (see Accesso-
ries, page 27).
16. Reinstall top brass louvers.
Shoulder
Screws
1. Unscrew four brass screws that attach
top louver to fireplace. Remove louver
from fireplace and set aside.
Hole for 3"
wood screw
for attaching
fireplace to
mantel
2. Place fireplace on wood base.
3. Place mantel around fireplace/base
assembly.
4. Assemble brass trim kit. See Assem-
bling Brass Trim, page 11.
Mantel Shelf
Hole for 3"
10"
wood screw for
attaching
fireplace to
Note:
All vertical
measurements
are from top of
fireplace
8"
6"
Assembled
Brass Trim
wooden base
1
2
/2"
opening to
bottom of
Figure 12 - Attaching Brass Trim to Fireplace
mantel shelf. All
measurements
are in inches.
Side of
Firebox
1 3/4" Screw
Wood
Base
Figure 13 - Attaching Wood Base to Floor
Figure 11 - Minimum Mantel Clearances
for Built-In Installation
104060
10
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Branch
Support
INSTALLING BLOWER
ACCESSORY GA3400T
INSTALLATION
Shoulder
Screw
Continued
Removing Upper Louver
Assembly
Assembling Brass Trim (Brass
trim shipped with mantel)
Remove
Screw
1. Remove packaging from three remain-
ing pieces of brass trim.
To install the blower accessory, you must
first remove the upper louver assembly.
Valve
Cover
Shield
2. Locate two adjusting plates with set 1. Lift screen off heater.
screws, and two shims in the hardware
2. Remove 4 screws from louver assem-
2
packet.
bly (see Figure 15). Save these screws.
3. Align shim under adjusting plate as
shown in Figure 14.
3. Pull louver assembly straight out from
the cabinet. Be careful not to scratch
the paint. Set louver assembly and
screws aside.
4. Slide one end of adjusting plate/shim
in slot on mitered edge of top brass trim
(see Figure 14).
1
Blower Bracket
Mounting Holes
5. Slide other end of adjusting plate/shim
in slot on mitered edge of side brass
trim (see Figure 14).
Bottom Louver
Assembly
Snap
Bushings
6. While firmly holding edges of brass
trim together, tighten both set screws
on the adjusting plate with slotted
screwdriver.
Figure 16 - Removing Valve Cover Shield
Installing Blower Assembly
7. Repeat steps 1 through 6 for other corner.
8. Set brass assembly aside for later in-
stallation.
Note: If you are using a mantel with your
heater, use the following instructions. If
your heater is built-in, see For Built-In In-
stallation on page 13.
Upper Louver
Assembly
Brass Screws
Top Brass
Trim
Set
1. Install snap bushings found in hardware
kit into both holes in rear of valve cover
shield.
Figure 15 - Removing Upper Louver
Assembly
Screws
Slot
2. Make sure the wire harness is firmly
connected to the terminals on the blower
bracket assembly.
Removing Valve Cover Shield
Mitered
Edge
1. Open bottom louver assembly by
swinging the assembly down (see Fig-
ure 16).
Shim
3. Note the wire locations on back of
AUTO/OFF/ON switch. The terminals
on back of switch are numbered 1, 2,
and 3. Carefully remove red wire from
terminal 1 and blue wire from terminal
3. Black wire can remain on middle
terminal 2 (see Figure 17, page 12).
Side Brass
Trim
2. Using short Phillips screwdriver, re-
move the screw under the center of the
branch support. Rotate valve cover
shield clockwise and slide out.
IMPORTANT: Do not remove shoul-
der screw on the left side of valve cover
shield. Slide the valve cover shield off
of the shoulder screw (see Figure 16).
Adjusting
Plate
Slot
Figure 14 - Assembling Brass Trim
Note: If you do not have a short
Phillips screwdriver, the screen, twigs,
and branch support must be removed
so a longer screwdriver may be used.
See Connecting Fireplace To Gas Sup-
ply, page 15 and follow step 2.
Continued
104060
11
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
6. Route the wire harness through the 9. Install the switch plate on the valve
INSTALLATION
hole in left side of baffle. Pull wire
harness through lower opening above
where the valve shield was removed.
(see Figure 17).
cover shield with 2 #10 screws provided
(see Figure 18). Reinstall the valve
cover shield. Route power cord out of
the cabinet by inserting it through the
bushing on the outer casing (see Fig-
ure 17). Plug fan kit into 120-Volt
grounded power supply and test opera-
tion. Note: When switch is in the
AUTO position, the fan will start after
the heater has run for a few moments.
The fan will continue to run for several
moments after the heater has been
turned off. When switch is in the ON
position, the fan will run until turned
to OFF. Reinstall upper louver assem-
bly and hood if previously removed,
(see Figure 15, page 11). Close lower
louver door.
Continued
4. Carefully disconnect green and white
wires at their insulated connectors.
7. Insert the 4 wire harness into one of the
round holes in the rear of the valve cover
shield and through the rectangular hole
in the front of shield (see Figure 17).
5. In top of the heater cabinet, locate the
four mounting holes on the outer cas-
ing. Align these four holes with those
on the blower bracket assembly. Attach
blower bracket assembly to the outer
casing with 4 #10 screws provided (see
Figure 17).
8. Reconnect red wire to switch position
3. Reconnect blue wire to switch posi-
tion 1. Reconnect green and white wires.
Wiring Routing
Hole in Baffle
Blower Bracket
Assembly
Screw
Baffle
Valve Cover
Shield
Wire
Harness
Switch
Plate
Switch
Screw
Power
Cord
Figure18-InstallingSwitchPlatetoValve
Cover Shield
3
2
1
Red
Blue
Switch
Plate
Wire
Harness
Valve Cover
Shield
Box Cover
Figure 17 - Installing Blower Bracket Assembly
104060
12
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Follow instructions Removing Valve Cover 3. Remove black plastic strain relief and
INSTALLATION
Shield (page 11), then
power cord from switch plate. The
power cord supplied will not be used in
built-in installations. Pop in the plastic
snap bushing found in hardware kit into
the hole left by supply cord/strain relief.
Continued
1. Install a snap bushing found in hard-
ware kit into one of the holes found on
rear of valve cover shield. The other
hole is for a strain relief clamp (not
For Built-In Installation
WARNING: A licensed elec-
trician must connect the wiring
harness to electrical supply fol-
lowing all local codes. Electri-
cian must provide a clamp on
the box cover to secure the wir-
ing. Wiring should be routed
through the bushing in the hole
on the outer casing of heater.
supplied) to secure incoming electrical 4. A licensed electrician must follow the
supply.
wiring diagram to connect incoming
electrical supply to fan kit wiring har-
ness (see Figure 20).
2. Follow steps 2 through 6 in Installing
Blower Assembly, pages 11 and 12.
Also remove black wire from middle 5. Plug power cord to the outlet receptacle
switch terminal 2.
(not provided) as shown in figure 19.
Wind the extra cable in power cord and
and tie it up with the plastic wire strap
(see Figure 19). Set the cable bundle
between the burner bracket and outer
casing, away from the burner.
6. Reinstall valve cover shield.
Blower Bracket
Assembly
7. Test to make sure the blower is work-
ing properly.
Screw
8. Reinstall upper louver assembly and
hood if previously removed, (see Figure
15, page 11). Close lower louver door.
Fan Switch
(Auto/Off/On)
Auto
1
2
Off
3
Thermostat
Switch
(N.O.)
Blue
On
Blue
110/115
V.A.C.
Red
Blower
Motor
Black
Red
White
Green
Switch
Wire
Harness
White
Green
Power
Cord
Figure 20 - Wiring Diagram For Blower
Accessory Built-In Installation
Outlet
Receptacle
3
2
1
Extension Cord
Red
Use extension cord if needed. The cord must
have a three-prong, grounding plug and a
three-hole receptacle. Make sure cord is in
good shape. It must be heavy enoughto carry
the current needed. An undersized cord will
cause a drop in line voltage. This will result
in loss of power and overheating. Use a No.
16 AWG cord for lengths less than 50 feet.
Blue
Switch Plate
Plastic Wire
Strap
Valve
Cover
Shield
Box Cover
Wire
Harness
Clamp Connector
(not included)
Figure 19 - Installing Blower Bracket Assembly
Continued
104060
13
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
Apply pipe joint sealant lightly to male
INSTALLATION
CAUTION:Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" or greater diameter to al-
low proper gas volume to fire-
place. If pipe is too small, un-
due loss of pressure will occur.
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.
Continued
Attaching Wood Base to Solid
Floor
CAUTION:Usepipejointseal-
ant that is resistant to liquid pe-
troleum (LP) gas.
For attaching base to solid floors (concrete
or masonry)
Note: Floor anchors and mounting screws
are in hardware package. The hardware
package is provided with fireplace.
We recommend that you install a sediment
trap in supply line as shown in Figure 22.
Locate sediment trap where it is within
reach for cleaning. Install in piping system
betweenfuelsupplyandheater.Locatesedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into fireplace controls. If sediment
trap is not installed or is installed wrong,
fireplace may not run properly.
Installation must include a manual shutoff
valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
fireplace (see Figure 22).
1. Drill holes at marked locations using
5/16" drill bit. For solid floors (con-
crete or masonry), drill at least 1" deep.
2. Fold floor anchor as shown in Figure 21.
3. Insert floor anchor (wings first) into
hole. Tap anchor flush to floor.
IMPORTANT: Install main gas valve
(manual shutoff valve) in an accessible
location. The main gas valve is for turning
on or shutting off the gas to the appliance.
4. Insert mounting screws through base
and into floor anchors.
5. Tighten screws until base is firmly fas-
tened to floor.
Approved Flexible
Gas Line
A.G.A. Design-Certified Manual
Shutoff Valve With 1/8" NPT Tap*
Figure 21 - Folding Anchor
CONNECTING TO GAS
SUPPLY
From Gas
Meter (5"
W.C. to
10.5" W.C.
Pressure)
WARNING: A qualified ser-
vice person must connect fire-
place to gas supply. Follow all
local codes.
3" Minimum
WARNING: Never connect
fireplace to private (non-utility)
gas wells. This gas is commonly
known as wellhead gas.
Pipe Nipple Cap Tee Joint
Sediment Trap
IMPORTANT:Check gas line pressure be-
fore connecting fireplace to gas line. Gas
line pressure must be no greater than 14
inchesofwater.Ifgaslinepressureishigher,
fireplace regulator damage could occur.
Figure 22 - Gas Connection
* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer.
See Accessories, page 27.
104060
14
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Branch
Support
INSTALLATION
Continued
Screen
Shipping
Screw
CONNECTING FIREPLACE
TO GAS SUPPLY
Installation Items Needed
• Phillips screwdriver
Shoulder
Screw
• sealant (resistant to propane/LP gas, not
provided)
1. Remove fireplace screen. Remove two
screws that hold fireplace screen in
place for shipping. These screws are
located near top of screen. Discard
screws. Lift fireplace screen up and pull
out to remove.
Flexible
Gas Line
2. Remove screws that attach branch sup-
port to fireplace (see Figure 23). Care-
fully lift up branch support and remove
from fireplace (see Figure 23).
Screen
3. Route flexible gas line (provided by
installer) from manual shutoff valve
into fireplace through side or rear ac-
cess holes in outer casing. Route flex-
ible gas supply line through fireplace
access holes in outer casing.
Figure 23 - Removing Branch Support From Fireplace
To Fireplace
Gas
Regulator
Gas Connector
Manual Shutoff Valve
NOTICE: Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
fromthefireplace(seeFigure23).
The flexible gas supply line con-
nection to the manual shutoff
valve should be accessible.
To Gas
Supply
Flexible Gas Line from
Flexible Gas Line from
Fireplace Gas Regulator
Manual Shutoff Valve
Provided With Fireplace
Provided By Installer
4. Apply pipe joint sealant lightly to male
threads of gas connector attached to
flexible gas line (see Figure 24). Con-
nect flexible gas line to flexible gas line
attached to gas regulator of fireplace
(see Figure 24).
Figure 24 - Attaching Flexible Gas Lines Together
5. Check all gas connections for leaks. See
Checking Gas Connections, page 16.
6. Replace branch support back into fire-
place. Feed flexible gas line into fire-
place base area while replacing branch
support. Make sure the entire flexible
gas line is in fireplace base area. Reat-
tach branch support to fireplace with
screws removed in step 2.
Continued
104060
15
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
TestPressuresEqualToorLessThan
1/2 PSIG
Pressure Testing Fireplace Gas
Connections
1. Open manual shutoff valve (see Figure
25).
INSTALLATION
Continued
1. Close manual shutoff valve (see Fig-
ure 25).
CHECKING GAS
CONNECTIONS
2. Pressurize supply piping system by either
using compressed air or opening main gas
valve located on or near gas meter.
2. Open main gas valve located on or near
gas meter.
3. Make sure control knob of fireplace is
in the OFF position.
WARNING: Test all gas pip-
ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.
3. Check all joints from gas meter to manual
shutoff valve (see Figure 26).Apply mix-
ture of liquid soap and water to gas joints.
Bubbles forming show a leak.
4. Check all joints from manual shutoff
valve to thermostat gas valve (see Fig-
ure 26). Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.
4. Correct all leaks at once.
WARNING:Neveruseanopen
flame to check for a leak. Apply a
mixture of liquid soap and water
toalljoints.Bubblesformingshow
a leak. Correct all leaks at once.
5. Correct all leaks at once.
Open
Manual
Shutoff
Valve
6. Light fireplace (see Operating Fire-
place, pages 17 and 18). Check all other
internal joints for leaks.
7. Turn off fireplace (see To Turn Off Gas
to Appliance, page 18).
Pressure Testing Gas Supply
Piping System
O
Closed
8. Replace front panel.
TestPressuresInExcessOf1/2PSIG
Figure 25 - Manual Shutoff Valve
1. Disconnect fireplace and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of 1/2
psig will damage fireplace regulator.
2. Cap off open end of gas pipe where
manual shutoff valve was connected.
Manual
Shutoff
Valve
3. Pressurize supply piping system by either
using compressed air or opening main gas
valve located on or near gas meter.
Gas Meter
4. Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.
5. Correct all leaks at once.
6. Reconnect heater and manual shutoff
valve to gas supply. Check reconnected
fittings for leaks.
Figure 26 - Checking Gas Joints
104060
16
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Note: You may be running this fire-
place for the first time after hooking
up to gas supply. If so, the control
knob may need to be pressed in for
30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up
when released, contact a qualified
service person or gas supplier for
repairs.
LIGHTING
INSTRUCTIONS
OPERATING
FIREPLACE
WARNING: You must operate
this fireplace with the fireplace
screen in place. Make sure fire-
place screen is installed before
running fireplace.
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: If you do not fol-
low these instructions exactly, a
fireorexplosionmayresultcaus-
ing property damage, personal
injury or loss of life.
NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Orange flame will also be
present. Open window to vent
smell. Operate fireplace on HI
position to burn off odor. This
will only last a few hours.
6. With control knob pressed in, push
down and release ignitor button.
This will light pilot. The pilot is at-
tached to the front of burner. If
needed, keep pressing ignitor but-
ton until pilot lights.
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly.
Note: If pilot does not stay lit, refer
to Troubleshooting, pages 20 through
22. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure, page 18.
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.
1. STOP! Read the safety information,
column 1.
2. Make sure manual shutoff valve is
fully open.
3. Turn control knob clockwise
to the OFF position.
WHAT TO DO IF YOU SMELL
GAS
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
4. Wait five (5) minutes to clear out any
gas.Then smell for gas, including near
the floor. If you smell gas, STOP! Fol-
low “B” in the safety information,
column 1. If you don’t smell gas, go
to the next step.
Note: If pilot goes out, repeat steps
3 through 7. This fireplace has a
safety interlock system. Wait one (1)
minute before lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The
main burner should light. Set control
knob to any heat level between HI
and LO.
5. Turn control knob counterclockwise
the PILOT position. Press
in control knob for five (5) seconds
(see Figure 27).
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.
Control Knob
CAUTION:Donottrytoadjust
heating levels by using the
manual shutoff valve.
Ignitor Button
Ignitor Electrode
D. Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part
of the control system and any gas con-
trol which has been under water.
Thermocouple
Pilot Burner
Figure 27 - Control Knob In The OFF
Position
Figure 28 - Pilot
(Actual Pilot May Vary From Illustration)
Continued
104060
17
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under Light-
OPERATING
FIREPLACE
Continued
ing Instructions, page 17.
2. With control knob pressed in, strike
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
match. Hold match to pilot until pi-
lot lights.
3. Keep control knob pressed in for 30
1. Turn control knob clockwise
seconds after lighting pilot. After 30
to the OFF position.
seconds, release control knob. Now
follow step 8, page 17.
2. Turn off all electric power to the ap-
pliance if service is to be performed.
Shutting Off Burner Only (pilot
stays lit)
OPERATING BLOWER
Turn control knob clockwise
the PILOT position.
to
This blower has three settings: ON, OFF,
andAUTO.IntheONposition,theblower
will operate constantly. In the OFF posi-
tion, the blower will not operate. In the
AUTOposition,theblowerwillstartwhen
thethermostatsensesasufficientincrease
in firebox temperature.
THERMOSTAT CONTROL
OPERATION
The thermostatic control used on this fire-
place differs from standard thermostats.
Standard thermostats simply turn on and
off the burner. The thermostat used on
this fireplace senses the room tempera-
ture. The thermostat adjusts the amount
of gas flow to the burner. This increases or
decreasestheburnerflameheight.Attimes
the room may exceed the set temperature.
If so, the burner will shut off. The burner
willcyclebackonwhenroomtemperature
drops below the set temperature.
Note: Your fireplace and thermostat
blower will not turn on and off at the
same time. The fireplace may run for
several minutes before the blower turns
on.Aftertheheatermodulatestothepilot
position, the blower will continue to run.
The blower will shut off after the firebox
temperature decreases.
Note: It is safe to operate fireplace with
blower turned off. However, the blower
helps distribute heated air from the
fireplace.
The control knob can be set to any heat
level between HI and LO.
Auto/Off/On Switch
Note: The thermostat sensing bulb mea-
sures the temperature of air near the
fireplace cabinet. This may not always
agree with room temperature (depend-
ing on housing construction, installation
location, room size, open air tempera-
tures, etc.). Frequent use of your fire-
place will let you determine your own
comfort levels.
Figure 29 - Auto/Off/On Switch
104060
18
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
BURNER FLAME PATTERN
INSPECTING
BURNER
Figure 32 shows a correct burner flame
pattern.Figure33showsanincorrectburner
flame pattern. The incorrect burner flame
patternshowsyellowtippingoftheflame. It
also shows the flame higher than one inch
above the log.
Check pilot flame pattern and burner flame
pattern often.
PILOT FLAME PATTERN
Figure30showsacorrectpilotflamepattern.
Figure 31 shows an incorrect pilot flame
pattern.Theincorrectpilotflameisnottouch-
ing the thermocouple. This will cause the
thermocouple to cool. When the thermo-
couple cools, the fireplace will shut down.
Note: When using the fireplace the first
time, the flame will be yellow for approxi-
mately one hour until the log cures.
WARNING: If yellow tipping
occurs, your fireplace could pro-
duce increased levels of carbon
monoxide. If burner flame pattern
shows yellow tipping, follow in-
structions at bottom of this page.
If pilot flame pattern is incorrect, as shown
in Figure 31
• turn fireplace off (see To Turn Off Gas to
Appliance, page 18)
• see Troubleshooting, pages 20 through 22
NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles enter the
fireplace and burn causing brief
patches of orange flame.
Thermocouple
Pilot Burner
Ifburnerflamepatternisincorrect,asshown
in Figure 33
• turn fireplace off (see To Turn Off Gas to
Appliance, page 18)
• see Troubleshooting, pages 20 through 22
Top of Flame About
One Inch Above Logs
Figure 30 - Correct Pilot Flame Pattern
(Actual Pilot May Vary From Illustration)
Thermocouple
Pilot Burner
Figure 32 - Correct Burner Flame Pattern
Yellow Tipping
Figure 31 - Incorrect Pilot Flame Pattern
(Actual Pilot May Vary From Illustration)
Figure33-IncorrectBurnerFlamePattern
104060
19
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
TROUBLESHOOTING
Note: For additional help, visit DESA
International’stechnicalservicewebsite
WARNING: Turn off and un-
plug fireplace and let cool before
servicing. Only a qualified ser-
vice person should service and
repair fireplace.
CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot.ThiscandamageODS/
pilot unit.
Note:Alltroubleshootingitemsarelistedin
order of operation.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no 1. Ignitor cable pinched or wet
spark at ODS/pilot
1. Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry
2. Ignitor electrode not connected to igni- 2. Reconnect ignitor cable
tor cable
3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode broken
6. Ignitor electrode positioned wrong
3. Replace ignitor cable
4. Replace piezo ignitor
5. Replace ignitor
6. Replace ignitor
When ignitor button is pressed, there is 1. Gas supply turned off or manual shutoff 1. Turn on gas supply or open manual
spark at ODS/pilot but no ignition
valve closed
shutoff valve
2. Control knob not in PILOT position
2. Turn control knob to PILOT position
3. Control knob not pressed in while in 3. Press in control knob while in PILOT
PILOT position
position
4. Air in gas lines when installed
4. Continue holding down control knob. Re-
peat igniting operation until air is removed
5. Clean ODS/pilot (see Cleaning and
Maintenance, page 23) or replace ODS/
pilot assembly
5. ODS/pilot is clogged
6. Gas regulator setting is not correct
6. Replace gas regulator
ODS/pilot lights but flame goes out when 1. Control knob not fully pressed in
1. Press in control knob fully
control knob is released
2. Control knob not pressed in long enough 2. After ODS/pilot lights, keep control
knob pressed in 30 seconds
3. Safety interlock system has been triggered 3. Wait one minute for safety interlock sys-
tem to reset. Repeat ignition operation
4. Manual shutoff valve not fully open
5. Thermocouple connection loose at con- 5. Hand tighten until snug, then tighten 1/4
trol valve turn more
4. Fully open manual shut-off valve
6. Pilot flame not touching thermocouple, 6. A) Contact local natural gas company
which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
B) Clean ODS/pilot (see Cleaning and
Maintenance, page 23) or replace ODS/
pilot assembly
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot
7. Thermocouple damaged
8. Control valve damaged
7. Replace thermocouple
8. Replace control valve
104060
20
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
1. Burner orifice is clogged
1. Clean burner (see Cleaning and Mainte-
nance, page 23) or replace burner orifice
2. Burner orifice diameter is too small
3. Inlet gas pressure is too low
2. Replace burner orifice
3. Contact local natural gas company
Delayed ignition of burner
1. Manifold pressure is too low
2. Burner orifice is clogged
1. Contact local natural gas company
2. Clean burner (see Cleaning and Mainte-
nance, page 23) or replace burner orifice
Burner backfiring during combustion
1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Mainte-
nance, page 23) or replace burner orifice
2. Replace burner pressure
2. Burner damaged
3. Low inlet gas pressure
4. Gas regulator defective
3. Contact local natural gas company
4. Replace gas regulator
Yellow flame during burner combustion
1. Not enough air
1. Check burner for dirt and debris. If
found, clean burner (see Cleaning and
Maintenance, page 23)
2. Gas regulator defective
2. Replace gas regulator
Slight smoke or odor during initial operation 1. Residues from manufacturing processes 1. Problem will stop after a few hours of
operation
Fireplace produces a whistling noise when 1. Turning control knob to HI position 1. Turn control knob to LO position and
burner is lit
when burner is cold
2. Air in gas line
let warm up for a minute
2. Operate burner until air is removed from
line. Have gas line checked by local
natural gas company
3. Air passageways on fireplace blocked
3. Observe minimum installation clear-
ances (see pages 8 through 10)
4. Dirty or partially clogged burner orifice 4. Clean burner (see Cleaning and Mainte-
nance, page 23) or replace burner orifice
Whitepowderresidueformingwithinburner 1. When heated, vapors from furniture pol- 1. Turn heater off when using furniture
box or on adjacent walls or furniture
ish, wax, carpet cleaners, etc. turn into
white powder residue
polish, wax, carpet cleaners, or similar
products
Continued
104060
21
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediatelycallyourgassupplierfromaneighbor’sphone. Followthe
gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT:Operatingfireplacewhereimpuritiesinairexistmaycreateodors.Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Fireplace produces a clicking/ticking noise 1. Metal expanding while heating or con- 1. This is common with most fireplaces. If
just after burner is lit or shut off
tracting while cooling
noise is excessive, contact qualified ser-
vice person
Fireplace produces unwanted odors
1. Fireplace burning vapors from paint, hair 1. Ventilate room. Stop using odor caus-
spray, glues, etc. (See IMPORTANT
ing products while fireplace is running
statement above)
2. Gas leak. SeeWarning statement at 2. Locate and correct all leaks (see Check-
top of page
ing Gas Connections, page 16)
Fireplace shuts off in use (ODS operates)
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Open window and/or door for ventilation
2. Contact local natural gas company
3. Clean ODS/pilot (see Cleaning and
Maintenance, page 23)
Gas odor even when control knob is in OFF 1. Gas leak. SeeWarning statement at 1. Locate and correct all leaks (see Check-
position
top of page
ing Gas Connections, page 16)
2. Control valve defective
2. Replace control valve
Gas odor during combustion
1. Foreign matter between control valve 1. Take apart gas tubing and remove for-
and burner eign matter
2. Gas leak. SeeWarning statement at 2. Locate and correct all leaks (see Check-
top of page
ing Gas Connections, page 16)
Moisture/condensationnoticedonwindows 1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Venti-
lation requirements (page 5)
104060
22
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
3. Blow air through the ports/slots and
CABINET
CLEANING AND
MAINTENANCE
holes in the burner.
Air Passageways
4. Check the injector holder located at the
end of the burner tube again. Remove • Use a vacuum cleaner or pressurized air
any large particles of dust, dirt, lint, or
pet hairs with a soft cloth or vacuum
cleaner nozzle.
to clean.
WARNING: Turn off fireplace
and let cool before cleaning.
Exterior
• Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabi-
net to remove dust.
5. Blow air into the primary air holes on
the injector holder.
CAUTION:Youmustkeepcon-
trol areas, burner, and circulating
air passageways of fireplace
clean. Inspect these areas of fire-
place before each use. Have fire-
place inspected yearly by a quali-
fiedserviceperson.Fireplacemay
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, etc.
6. In case any large clumps of dust have
now been pushed into the burner repeat
steps 3 and 4.
Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 35). With the unit off, lightly
blow air through the air inlet hole. You may
blowthroughadrinkingstrawifcompressed
air is not available.
CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE
Injector Holder
The primary air inlet holes allow the proper
amount of air to mix with the gas. This
provides a clean burning flame. Keep these
holesclearofdust, dirt, andlint. Cleanthese
air inlet holes prior to each heating season.
Blocked air holes will create soot. We rec-
ommend that you clean the unit every 2,500
hours of operation or every three months.
Ports/Slots
Burner
Tube
Primary Air Inlet
Holes
Wealsorecommendthatyoukeeptheburner
tube and pilot assembly clean and free of
dustanddirt.Tocleanthesepartswerecom-
mend using compressed air no greater than
30 PSI. Your local computer store, hard-
ware store, or home center may carry com-
pressed air in a can. You can use a vacuum
cleaner in the blow position. If using com-
pressed air in a can, please follow the direc-
tions on the can. If you don't follow direc-
tions on the can, you coulddamage the pilot
assembly.
Figure 34 - Injector Holder On Outlet
Burner Tube
Pilot Air Inlet
Hole
1. Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.
Pilot Assembly
Figure 35 - Pilot Inlet Air Hole
2. Inspect burner, pilot, and primary air
inlet holes on injector holder for dust
and dirt (see Figure 34).
104060
23
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
ILLUSTRATED
3
PARTS
17
1
BREAKDOWN
9
VMH26TNA
30
7
4
8
27
43
3
10
35-1
7
43
4
2
33
11
14
25
24
29
20
12-1
23
43
13
35-2
37
14
32
40
34
19
5
38
25
6
12
28
24
15
18
26
39
36
22
42
12-1
12-2
21
41
16
31
104060
24
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
PARTS LIST
VMH26TNA
KEY NO.
PART NO.
DESCRIPTION
QTY.
1
2
3
4
5
6
7
8
102633-02CK
102624-02
099230-02
098304-01
103447-02
103209-03
102635-02CK
101629-02
103209-01
101712-04
102638-01
103042-01
098514-01
098594-01
102460-01CJ
099211-01
103963-01
102834-01
100587-01
098303-02
104335-01CK
102649-01CJ
099415-10
102875-01
101381-01
099387-11
098271-06
103845-12
102458-01CK
098249-01
098522-14
102639-01
101628-01
102869-01
102731-01
103295-01CJ
103058-01
104058-01
104058-02
104313-01
104313-02
M10908-2
Outer Casing Top
Outer Casing
Shoulder Screw
Screw, #10 x 3/8"
Burner
Louvered Door
Left and Right Side Front
Bushing
Brass Top Louver
Firebox Hood
Firebox Top
ODS/Pilot Assembly
Thermocouple
Ignitor Electrode
Firebox Wrapper
Control Bracket Screw
Inlet Tube
1
1
12
14
1
1
2
1
1
1
1
1
1
1
1
2
1
1
4
2
1
1
1
1
1
1
1
1
1
6
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
28
This list contains replaceable parts used in
your fireplace. When ordering parts, follow
the instructions listed under Replacement
Parts on page 26 of this manual.
9
10
11
12
12-1
12-2
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
35-1
35-2
36
37
38
39
40
41
42
43
Burner Tube
Brass Screw, #6 x 3/8
Regulator Screw
Outer Shell Base
Branch Support
Gas Regulator
Regulator Bracket
Valve Cover and Piezo
Pilot Tube
Ignitor Cable
Injector
Front, Top Middle
Nut, M5
Gas Valve
Baffle
Flexible Connector
Control Bracket
Control Shield
Screen Assembly
Log Set Assembly
Branch Service Kit
Back Log Service Kit
Right Hinge
Left Hinge
Hinge Screws
Burner Support, Right
Burner Support, Left
3/8" NPT x 3/8" Flare Brass Fitting
Bushing
102645-02
102645-03
097809-03
101629-01
M11084-26
Hex Head Screw, #10 x 3/8"
PARTS AVAILABLE — NOT SHOWN
104319-02
Information Video
Lighting Instructions Plate
Warning Plate
1
1
1
1
101054-01
100563-01
103470-01
Hardware Package
104060
25
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH26TNA
COMPACT CLASSIC HEARTH FIREPLACE
SPECIFICATIONS
REPLACEMENT
PARTS
Btu (Variable)
Type Gas
14,000/26,000
Natural Only
Piezo
Note: Use only original replacement parts.
Thiswillprotectyourwarrantycoveragefor
parts replaced under warranty.
Ignition
Pressure Regulator Setting
3" W.C.
Inlet Gas Pressure (in. of water) *
Maximum
PARTS UNDER WARRANTY
10.5"
5"
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) call DESA International’s Technical
Service Department at 1-800-323-5190 for
referral information.
Minimum
Dimensions, Inches (H x W x D)
Fireplace (including hood and screws)
Carton
25 7/8 x 26 13/16 x 9 3/8
32 5/8 x 27 3/16 x 11 5/8
Weight, pounds
Fireplace
When calling DESA International, have
ready
44 1/2 lbs.
48 lbs.
Shipping
• your name
* For purposes of input adjustment
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
TECHNICAL
SERVICE
SERVICE HINTS
• type of gas used (propane/LP or natural
gas)
When Gas Pressure Is Too Low
• purchase date
You may have further questions about in-
stallation, operation, or troubleshooting.
• pilot will not stay lit
• burner will have delayed ignition
• fireplace will not produce specified heat
Usually, we will ask you to return the defec-
tive part to the factory.
If so, contact DESA International’s Techni-
cal Service Department at 1-800-323-5190.
PARTS NOT UNDER
WARRANTY
When Gas Quality Is Bad
• pilot will not stay lit
You can also visit DESA International’s
technical services web site at
• burner will produce flames and soot
• fireplace will backfire when lit
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) call DESA International’s Parts De-
partment at 1-800-972-7879 for referral in-
formation.
Youmayfeelyourgaspressureistoolowor
gas quality is bad. If so, contact your local
natural gas supplier.
When calling DESA International, have
ready
• model number of your fireplace
• the replacement part number
104060
26
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
ACCESSORIES
CABINET MANTEL WITH
BUILT-IN HEARTH BASE
Unfinished - GM921U
Purchase these fireplace accessories from
your local dealer. If they cannot supply these
accessories call DESA International’s Sales
Department at 1-800-458-2472 for referral
information. You can also write to the ad-
dress listed on the back page of this manual.
Finished - GM920F
For use with fireplace. A hardwood mantel
and hearth base offers compact styling and
completes the fireplace look. Available in a
walnut finished or an unfinished hardwood,
ready to stain or paint. Complete assembly
instructionsincluded.Three-sidedbrasstrim
kit included.
MANUAL SHUTOFF VALVE
GA5010
Manual shutoff valve with 1/8" NPT tap.
CABINET MANTEL WITH
BUILT-IN HEARTH BASE
Unfinished - GM923U
Finished - GM922F
For use with fireplace. A hardwood mantel
and hearth base offers compact styling and
completes the fireplace look. Available in a
stained or an unfinished (ready to stain or
paint) Oak Veneer over hardwood. Com-
pleteassemblyinstructionsincluded.Three-
sided brass trim kit included.
BRASS TRIM KIT - GA6094
Optional three-sided brass trim kit for cus-
tom and recessed installations (when unit is
on the floor). Provides a finished appear-
ance by covering rough edges of wall open-
ing. Included with all mantels.
BRASS TRIM KIT - GA6095
Optional four-sided brasstrim kit forrecessed
built-ininstallations(whenunitisraisedoffof
the floor. Provides a finished appearance by
covering rough edges of wall opening.
CORNER MANTEL WITH
BUILT-IN HEARTH BASE
Unfinished - GM721U
Finished - GM720F
Forusewithfireplace. Space-savingmantel
andhearthbasecornerdesignfeaturesclean,
classic lines. Available in a walnut finish or
an unfinished hardwood, ready to stain or
paint. Complete assembly instructions in-
cluded. Three-sided brass trim kit included.
THERMOSTATICALLY -
CONTROLLED BLOWER KIT
GA3400T
Providesbetterheatdistribution.Makesfire-
place more efficient. Automatically turns
off and on as needed.
104060
27
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written
warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
VENT-FREE NATURAL GAS COMPACT CLASSIC HEARTH® FIREPLACE
DESA International warrants this product to be free from defects in materials and components for four (4) years and five (5) years
on stainless steel burners from the date of first purchase, provided that the product has been properly installed, operated and
maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check
must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this
fireplace to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty
part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory
replacement parts. Failure to use original factory replacement parts voids this warranty. The fireplace MUST be installed by a
qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become
damagedasaresultofmisuse, accidents, lackofpropermaintenanceordefectscausedbyimproperinstallation. Travel, diagnosticcost,
labor, transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE
PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND
LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTA-
BILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS AND FIVE (5)
YEARS ON STAINLESS STEEL BURNERS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S
LIABILITYISHEREBYLIMITEDTOTHEPURCHASEPRICEOFTHEPRODUCTANDDESAINTERNATIONALSHALL
NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSE-
QUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential
damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
INTERNATIONAL
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
104060-01
104060 01
REV. D
01/00
NOT A UPC
Download from Www.Somanuals.com. All Manuals Search And Download.
|