VENT-FREE PROPANE/LP GAS
COMPACT CLASSIC HEARTH® FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
VMH10TPA
10,000 Btu/Hr with
Thermostat
Shown with Optional
Cabinet Mantel/Hearth
Base Accessory
WARNING: Improper installa-
tion,adjustment,alteration,ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installationandoperationalpro-
cedures. For assistance or ad-
ditional information consult a
qualified installer, service
agency, or the gas supplier.
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
•
•
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
•
•
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
fire department.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed.Provisionsforadequate
combustion and ventilation air
mustbeprovided. RefertoAirfor
Combustion and Ventilationsec-
tion on page 5 of this manual.
— Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is
not convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
PRODUCT
PRODUCT
FEATURES
IDENTIFICATION
Fireplace
Cabinet
SAFETY PILOT
This fireplace has a pilot with an Oxygen
Depletion Sensor Shutoff System (ODS).
The ODS/pilot is a required feature for vent-
freeroomfireplaces.TheODS/pilotshutsoff
the fireplace if there is not enough fresh air.
Screen
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This sys-
tem requires no matches, batteries, or other
sources to light fireplace.
THERMOSTATIC HEAT
CONTROL
Logs
This fireplace has a thermostat sensing bulb
and a control valve. The thermostat will
automatically modulate the heat output to
maintain a consistent room temperature.
This results in greater fireplace comfort.
This can also result in lower gas bills.
Control Knob
Ignitor Button
Figure 1 - Vent-Free Propane/LP Gas Compact Fireplace
LOCAL CODES
UNPACKING
1. Remove log box and fireplace from
carton. The hood is not attached.
Install and use fireplace with care. Follow all
localcodes.Intheabsenceoflocalcodes,use
the latest edition of The National Fuel Gas
CodeANSZ223.1,alsoknownasNFPA54*.
2. Remove all protective packaging ap-
plied to fireplace for shipment.
3. Make sure your fireplace includes one
hardware packet.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
4. Check fireplace for any shipping damage.
If fireplace is damaged, promptly inform
dealer where you bought fireplace.
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
104407
3
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
Screen
ASSEMBLY
Shipping
Back Log
Screw
Shoulder
Screw
WARNING: Always have
branch support and screen in
place before operating fireplace.
Thispreventsexcessivetempera-
tures on fireplace surfaces.
Burner
Support
ASSEMBLING FIREPLACE
Tools Required:
Screw
• Phillips screwdriver
• 5/16" hex wrench
• slotted screwdriver
Installing Log
1. Remove back log, branch, and hood from
log box. Discard protective packaging.
2. Remove two shipping screws above
screen (see Figure 2).
Branch
Support
3. Lift screen up and pull out to remove.
4. An optional blower is available. See Ac-
Screw
cessories, page 27. Install optional
blower now. Follow installation in-
structions provided with blower.
Screen
Branch
5. Gently place back log on burner sup-
port (see Figure 2). The log should fit
flat against top of burner support. Place
two #10 one-inch-long screws through
burner support into the log and tighten.
Figure 2 - Assembling Fireplace
Assembling Hood
1. Locate four #10-3/8" black phillips
sheet metal screws from the hardware
packet.
6. Place branch on branch support (see
Figure 2). Do not allow branch to con-
tact flame. If flame contacts branch,
soot will be created.
2. Slip top of hood between middle rail and
top of firebox wrapper (see Figure 3).
3. Attach four #10-3/8" hood screws as
shown in Figure 3.
7. Reattach screen by placing the notches
in the screen frame over the shoulder
screws and pushing down.
Upper Louver
Assembly
Middle
Rail
WARNING: Failure to position
thepartsinaccordancewiththese
diagrams or failure to use only
parts specifically approved with
this fireplace may result in prop-
erty damage or personal injury.
Firebox
Wrapper
Hood
#10-3/8"
Screws
Figure 3 - Assembling Hood
104407
4
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Confined and Unconfined Space
PROVIDING ADEQUATE
VENTILATION
AIR FOR
The National Fuel Gas Code (ANS Z223.1,
1992 Section 5.3) defines a confined space
as a space whose volume is less than 50
cubic feet per 1,000 Btu per hour (4.8 m3 per
kw) of the aggregate input rating of all
appliances installed in that space and an
unconfining space as a space whose volume
is not less than 50 cubic feet per 1,000 Btu
per hour (4.8 m3 per kw) of the aggregate
inputratingofallappliancesinstalledinthat
space. Rooms communicating directly with
the space in which the appliances are in-
stalled*, through openings not furnished
with doors, are considered a part of the
unconfined space.
COMBUSTION AND
VENTILATION
The following are excerpts from National
Fuel Gas Code. NFPA 54/ANS Z223.1, Sec-
tion5.3, AirforCombustionandVentilation.
WARNING: This heater shall
notbeinstalledinaconfinedspace
or unusually tight construction
unless provisions are provided
foradequatecombustionandven-
tilation air. Read the following in-
structions to insure proper fresh
air for this and other fuel-burning
appliances in your home.
All spaces in homes fall into one of the three
following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 5 through 7 will
help you classify your space and provide
adequate ventilation.
Unusually Tight Construction
Today’s homes are built more energy effi-
cient than ever. New materials, increased
insulation, and new construction methods
helpreduceheatlossinhomes.Homeowners
weather strip and caulk around windows and
doorstokeepthecoldairoutandthewarmair
in. During heating months, home owners
want their homes as airtight as possible.
This heater shall not be installed in a con-
fined space or unusually tight construction
unless provisions are provided for adequate
combustion and ventilation air.
The air that leaks around doors and win-
dows may provide enough fresh air for
combustion and ventilation. However, in
buildings of unusually tight construction,
you must provide additional fresh air.
* Adjoining rooms are communicating only
iftherearedoorlesspassagewaysorventila-
tion grills between them.
Unusually tight construction is de-
fined as construction where:
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper com-
bustion and ventilation.
a. walls and ceilings exposed to the
outside atmosphere have a con-
tinuous water vapor retarder with
a rating of one perm (6 x 10-11 kg
per pa-sec-m2) or less with open-
ings gasketed or sealed and
Exhaustfans, fireplaces, clothesdryers, and
fuel burning appliances draw air from the
house to operate. You must provide ad-
equate fresh air for these appliances. This
will insure proper venting of vented fuel-
burning appliances.
b. weather stripping has been
added on openable windows and
doors and
c. caulking or sealants are applied
to areas such as joints around
window and door frames, be-
tween sole plates and floors, be-
tween wall-ceiling joints, be-
tween wall panels, at penetra-
tions for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three
criteria above, you must provide ad-
ditional fresh air. See Ventilation Air
From Outdoors, page 7.
If your home does not meet all of the
three criteria above, proceed to De-
termining Fresh-Air Flow For Fire-
place Location, page 6.
Continued
104407
5
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
AIR FOR
COMBUSTION AND
VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION
Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height = _________________cu. ft. (volume of space)
Example: Space size 16 ft. (length) x 14 ft. (width) x 8 ft. (ceiling height) = 1792 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of
the space.
2. Multiply the space volume by 1000 Btu/Hr per 50 cubic feet to determine the maximum Btu/Hr the space can support.
_____________________(volume of space) x (1000 Btu/Hr ÷ 50 cu. ft.) = (Maximum Btu/Hr the space can support)
Example: 1792 cu. ft. (space volume) x (1000 Btu/Hr ÷ 50 cu. ft.) = 35,840 Btu/Hr. This is the maximum Btu/Hr the space can
support.
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free fireplace
Gas water heater*
Gas furnace
______________________ Btu/Hr
______________________ Btu/Hr
______________________ Btu/Hr
______________________ Btu/Hr
______________________ Btu/Hr
Example:
Gas water heater
Vent-free fireplace + 10,000 Btu/Hr
Total 40,000 Btu/Hr
30,000 Btu/Hr
Vented gas heater
Gas fireplace logs
=
Other gas appliances* + ______________________ Btu/Hr
Total = ______________________ Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_________________ Btu/Hr (maximum the space can support)
_________________ Btu/Hr (actual amount of Btu/Hr used)
Example: 35,840 Btu/Hr (maximum the space can support)
40,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support.
You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining
room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7.
C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space
or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the
methods described in the National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3 or applicable local codes.
104407
6
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
AIR FOR
COMBUSTION AND
VENTILATION
12"
Continued
VENTILATION AIR
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilation Air From Inside
Building
Ventilation
Grills
Or
Thisfreshairwouldcomefromanadjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must pro-
vide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 4). You can also
remove door into adjoining room (see op-
tion 3, Figure 4). Follow the National Fuel
Gas Code NFPA 54/ANS Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
into Adjoining
Room,
Option 1
Remove
Door into
Adjoining
Room,
Option 3
12"
WARNING: Rework work-
sheet, adding the space of the
adjoining unconfined space. The
combined spaces must have
enough fresh air to supply all
appliances in both spaces.
Figure 4 - Ventilation Air from Inside Building Shown with Optional Mantel
Ventilation Air From Outdoors
Ventilated
Outlet
Attic
Air
Provide extra fresh air by using ventilation
grills or ducts. You must provide two per-
manent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
orspacesopentotheoutdoors.Thesespaces
include attics and crawl spaces. Follow the
National Fuel Gas Code NFPA 54/ANS
Z223.1,Section5.3,AirforCombustionand
Ventilation for required size of ventilation
grills or ducts.
Outlet
Air
To Attic
To
Crawl
Space
IMPORTANT:Do not provide openings for
inlet or outlet air into attic if attic has a
thermostat-controlledpowervent.Heatedair
enteringtheatticwillactivatethepowervent.
Inlet
Air
Ventilated
Inlet Air
Crawl Space
Figure 5 - Ventilation Air from Outdoors Shown with Optional Mantel
104407
7
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
chase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See
Accessories, page 27.
INSTALLATION
CAUTION:Thisheatercreates
warmaircurrents.Thesecurrents
moveheattowallsurfacesnextto
heater. Installing heater next to
vinyl or cloth wall coverings or
operatingheaterwhereimpurities
(suchastobaccosmoke,aromatic
candles, cleaning fluids, oil or
kerosene lamps, etc.) in the air
exist, may discolor walls.
NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’scirculatingblowerwhile
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater as
your primary heat source.
Note:Ifdesired,purchaseafour-sidedbrass
trim kit for built-in installations. See Acces-
sories, page 27.
LOCATING FIREPLACE
WARNING:Maintainthemini-
mumclearancesshowninFigure
6 and Figure 7, page 9. If you can,
provide greater clearances from
floor, ceiling, and joining wall.
CAUTION: If you install the
fireplace in a home garage
• fireplacepilotandburnermust
be at least 18 inches above
floor.
NOTICE: If you install the fire-
place in a bedroom, some build-
ing codes require that the fire-
place/mantel system be secured
to (or within) a wall. You can po-
sitionfireplaceinanoptionalcabi-
net or corner mantel. You can
alsorecessfireplaceintothewall.
WARNING: A qualified ser-
vicepersonmustinstallfireplace.
Follow all local codes.
• locate fireplace where moving
vehicle will not hit it.
For convenience and efficiency, install fire-
place
Note: Your Vanguard fireplace is designed
to be used in zero clearance installations.
Wall or framing material can be placed
directly against any exterior surface on the
rear, sides, or top of your fireplace, except
where standoff spacers are integrally at-
tached. If standoff spacers are attached to
your fireplace, these spacers can be placed
directly against wall or framing materials.
• where there is easy access for operation,
inspection, and service
If your fireplace is to be used with an op-
tional mantel, the installation instructions
included with your mantel shows an AGA
approved method of attaching the fireplace/
mantel system to a wall. IMPORTANT:
Only use optional cabinet or corner mantels
specified in this manual. Purchase the op-
tional mantel from your dealer (see Acces-
sories, page 27).
• in coldest part of room
An optional blower kit is available from
your dealer. See Accessories, page 27. If
planning to use blower, follow instructions
provided with blower for power source.
Use the dimensions shown for rough open-
ings to create the easiest installation (see
Built-In Fireplace Installation, page 9).
IMPORTANT:Vent-freefireplacesaddmois-
ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilationairmaycausemildewtoformfrom
too much moisture. See Air for Combustion
and Ventilation, pages 5 through 7.
If your fireplace is to be recessed into the
wall, see Built-In Fireplace Installation on
page9 tosecureyourfireplaceintothewall.
CHECK GAS TYPE
Useonlypropane/LPgas.Ifyourgassupply
is not propane/LP, do not install fireplace.
Call the dealer where you bought your fire-
place for the proper type fireplace.
CEILING
WARNING: Never install the
fireplace
• in a bathroom
INSTALLATION ITEMS
36"
Minimum
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objectsarelessthan36inches
from the front, top, or sides of
the fireplace
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
Before installing fireplace, make sure you
have the items listed below.
6"
Minimum
From
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve *
• test gauge connection*
• ground joint union
Sides Of
Fireplace
Left
Side
Right
Side
• sediment trap
• tee joint
• pipe wrench
FLOOR
* AnA.G.A.design-certifiedmanualshutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
Figure 6 - Mounting Clearances As
Viewed From Front of Fireplace Shown
Built In The Wall
104407
8
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
4. If you have not assembled firebox, fol-
low instructions on page 4.
INSTALLATION
Continued
5. Carefully set fireplace in front of rough
opening with back of fireplace inside
wall opening.
CEILING
10 1/2"
26 7/8"
6. Attach flexible gas line to fireplace gas
regulator. See Connecting Fireplace to
Gas Supply, page 15.
36"
Minimum
Top Of
3/4" Off
The Floor
Minimum
Mantel Can
Be Flush
With Wall
7. If the optional blower has been installed
connect blower to electrical source.
26 7/8"
Figure8-RoughOpeningforInstallingin
Wall
Options one and two: Route blower
electrical cord through side or rear ac-
cess door of fireplace. Plug electrical
cord into electrical outlet.
Right
Side
Left
Side
36 5/8"
Option three: Have a licensed elec-
trician connect blower to electrical
source at junction box inside fireplace.
25 7/8"
26 7/8"
51 3/4"
8. Bend four nailing flanges on outer cas-
ing with pliers (see Figure 10).
Figure7-MountingClearancesAsViewed
From Front of Fireplace Shown with Op-
tional Mantel
9. Attach fireplace to wall studs using
nails or wood screws through holes in
nailing flange.
Figure9-RoughOpeningforInstallingin
Corner
BUILT-IN FIREPLACE
INSTALLATION
2. An optional blower accessory is avail-
able (see Accessories, page 27). There
are three options for connecting blower
to electrical source.
10. Check all gas connections for leaks. See
Checking Gas Connections, page 16.
Built-ininstallationofthisfireplaceinvolves
installing fireplace into a framed-in enclo-
sure. This makes the front of fireplace flush
with wall. An optional brass trim kit acces-
sory is available (see Accessories, page 27).
Brasstrimwillextendpastsidesoffireplace
approximately 1/2 inch. This will cover the
rough edges of the wall opening. If install-
ingabuilt-inmantelabovethefireplace, but
you must follow the clearances shown in
Figure 11, page 10. Follow the instructions
below to install the fireplace in this manner.
Note: Your Vanguard fireplace is designed
to be used in zero clearance installations.
Wall or framing material can be placed
directly against any exterior surface on the
rear, sides, or top of your fireplace.
11. If using optional brass trim kit, install
the trim after final finishing and/or
painting of wall. See instructions in-
cluded with brass trim accessory for at-
taching brass trim.
Option one: Install fireplace near an
electrical outlet. See blower instruc-
tions for power cord length.
Option two: Have a licensed electri-
cian install a properly grounded, three-
prong 120-volt electrical outlet at fire-
place location. Locate outlet inside the
framed enclosure. Blower power cord
will plug into this outlet.
Nails or
Wood
Screws
Option three: Have a licensed elec-
trician connect blower to electrical
source at junction box inside fireplace.
If using option one, have electrical out-
let installed at this time. If using option
two, do not connect blower to electrical
source at junction box until step 7.
Actual
26"
26 3/4"
9 1/2"
3/4"
Framing
26 7/8"
26 7/8"
10 1/2"
3/4"
3. Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the manual shutoff valve.
The flexible gas line must be the last
item installed on the gas piping.
Height
Front Width
Depth
Nailing
Flanges
Bottom
Figure 10 - Attaching Fireplace to Wall
Studs
1. Frame in rough opening. Use dimensions
shown in Figure 8 for the rough opening.
If installing in a corner, use dimensions
shown in Figure 9 for the rough open-
ing. The height is 26 7/8" which is the
same as the wall opening above.
Continued
104407
9
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
8. Place assembly next to wall at installa-
OPTIONAL MANTEL
INSTALLATION
INSTALLATION
tion location.
Continued
9. Remove brass trim kit and mantel. Be
Note: Refer to instructions provided with
Mantel Clearances for Built-In
Installation
careful not to damage wall or mantel.
the mantel for assembly instructions. Refer
to instructions below for system installa-
tion. Refer to instructions on page 4 for
firebox assembly. Blower accessory should
be installed if it is being used (see Installing
Blower Accessory GA3400T, page 11).
10. Attach wood base to floor with two 1 3/4"
black screws provided (see Figure 13). If
the floor is concrete use anchor method
(see Attaching Wood Base to Solid Floor,
page 14).
If placing mantel above built-in fireplace,
youmustmeetminimumclearancebetween
mantel shelf and top of fireplace opening.
If your installation does not meet the below
minimum clearances, you must:
11. Install gas line. See Connecting To Gas
Supply, page 14.
1. Unscrew four brass screws that attach
top louver to fireplace. Remove louver
from fireplace and set aside.
• raise the mantel to an acceptable height,
12. Check for leaks. See Checking Gas
Connections, page 16.
OR
2. Place fireplace on wood base.
• remove the mantel.
13. Place mantel around fireplace. Be care-
ful not to damage wall or mantel.
3. Place mantel around fireplace/base as-
sembly.
Mantel Shelf
14. Place brass trim kit on the shoulder
screws located on the side and top of
the fireplace. Firmly snap the brass trim
over the shoulder screws on fireplace
(see Figure 12).
4. Assemble brass trim kit. See Assem-
bling Brass Trim, page 11.
10"
Note:
5. Firmly snap brass trim kit on shoulder
screws. Shoulder screws are located on
fireplace cabinet (see Figure 12).
8"
6"
All vertical
measurements
are from top of
fireplace
15. Adjust assembly to remove any gaps.
Attach remaining two 3" wood screws
from hardware pack through openings
inside of fireplace sides into the man-
tel. The openings are located at top be-
hind the area for the brass louvers (see
Figure 13).
1
6. Align brass trim kit for flush fit around
opening.
2 /2"
opening to
bottom of
mantel shelf. All
measurements
are in inches.
7. Use two 3" wood screws provided and
attach fireplace base to wooden base
(see Figure 12).
16. Reinstall top brass louvers.
Shoulder
Screws
Hole for 3"
wood screw
for attaching
fireplace to
mantel
Side of
Firebox
Figure 11 - Minimum Mantel Clearances
for Built-In Installation
Hole for 3"
wood screw for
attaching
fireplace to
wooden base
Assembled
Brass Trim
Figure 12 - Attaching Brass Trim to Fireplace
1 3/4" Screw
Wood Base
Figure 13 - Attaching Wood Base to Floor
104407
10
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Branch
Support
INSTALLING BLOWER
ACCESSORY GA3400T
INSTALLATION
Shoulder
Screw
Continued
Assembling Brass Trim (Brass
trim shipped with mantel)
1. Remove packaging from three remain-
ing pieces of brass trim.
Removing Upper Louver
Assembly
Remove
Screw
To install the blower accessory, you must
first remove the upper louver assembly.
Valve
Cover
Shield
2. Locate two adjusting plates with set
screws, and two shims in the hard-
ware packet.
1. Lift screen off heater.
2. Remove 4 screws from louver assem-
bly (see Figure 15). Save these screws.
2
3. Align shim under adjusting plate as
shown in Figure 14.
3. Pull louver assembly straight out from
the cabinet. Be careful not to scratch
the paint. Set louver assembly and
screws aside.
4. Slide one end of adjusting plate/shim
in slot on mitered edge of top brass trim
(see Figure 14).
1
5. Slide other end of adjusting plate/shim
in slot on mitered edge of side brass
trim (see Figure 14).
Blower Bracket
Mounting Holes
Bottom Louver
Assembly
Snap
Bushings
6. While firmly holding edges of brass
trim together, tighten both set screws
on the adjusting plate with slotted
screwdriver.
Figure 16 - Removing Valve Cover Shield
7. Repeat steps 1 through 6 for other corner.
Installing Blower Assembly
8. Set brass assembly aside for later in-
stallation.
Note: If you are using a mantel with your
heater, use the following instructions. If
your heater is built-in, see For Built-In In-
stallation on page 13.
Upper Louver
Assembly
Top Brass Trim
Brass Screws
Set
Screws
Slot
1. Install snap bushings found in hardware
kit into both holes in rear of valve cover
shield.
Figure 15 - Removing Upper Louver As-
sembly
Mitered Edge
2. Make sure the wire harness is firmly
connected to the terminals on the blower
bracket assembly.
Shim
Removing Valve Cover Shield
Side Brass
Trim
1. Open bottom louver assembly by
swinging the assembly down (see Fig-
ure 16).
Adjusting
Plate
3. Note the wire locations on back of
AUTO/OFF/ON switch. The terminals
on back of switch are numbered 1, 2,
and 3. Carefully remove red wire from
terminal 1 and blue wire from terminal
3. Black wire can remain on middle
terminal 2 (see Figure 17, page 12).
2. Using short Phillips screwdriver, re-
move the screw under the center of the
branch support. Rotate valve cover
shield clockwise and slide out.
IMPORTANT: Do not remove shoul-
der screw on the left side of valve cover
shield. Slide the valve cover shield off
of the shoulder screw (see Figure 16).
Slot
Figure 14 - Assembling Brass Trim
Note: If you do not have a short
Phillips screwdriver, the screen, twigs,
and branch support must be removed
so a longer screwdriver may be used.
See Connecting Fireplace To Gas Sup-
ply, page 15 and follow step 2.
Continued
104407
11
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
6. Route the wire harness through the 9. Install the switch plate on the valve
INSTALLATION
hole in left side of baffle. Pull wire
harness through lower opening above
where the valve shield was removed.
(see Figure 17).
cover shield with 2 #10 screws provided
(see Figure 18). Reinstall the valve
cover shield. Route power cord out of
the cabinet by inserting it through the
bushing on the outer casing (see Fig-
ure 17). Plug fan kit into 120-Volt
grounded power supply and test opera-
tion. Note: When switch is in the
AUTO position, the fan will start after
the heater has run for a few moments.
The fan will continue to run for several
moments after the heater has been
turned off. When switch is in the ON
position, the fan will run until turned
to OFF. Reinstall upper louver assem-
bly and hood if previously removed,
(see Figure 15, page 11). Close lower
louver door.
Continued
4. Carefully disconnect green and white
wires at their insulated connectors.
7. Insert the 4 wire harness into one of the
round holes in the rear of the valve cover
shield and through the rectangular hole
in the front of shield (see Figure 17).
5. In top of the heater cabinet, locate the
four mounting holes on the outer cas-
ing. Align these four holes with those
on the blower bracket assembly. Attach
blower bracket assembly to the outer
casing with 4 #10 screws provided (see
Figure 17).
8. Reconnect red wire to switch position
3. Reconnect blue wire to switch posi-
tion 1. Reconnect green and white wires.
Wiring Routing
Hole in Baffle
Blower Bracket
Assembly
Screw
Baffle
Valve Cover
Shield
Wire
Harness
Switch
Plate
Switch
Screw
Power
Cord
Figure18-InstallingSwitchPlatetoValve
Cover Shield
3
2
1
Red
Blue
Switch
Plate
Wire
Harness
Valve Cover
Shield
Box Cover
Figure 17 - Installing Blower Bracket Assembly
104407
12
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Follow instructions Removing Valve Cover 3. Remove black plastic strain relief and
INSTALLATION
Shield (page 11), then
power cord from switch plate. The
power cord supplied will not be used in
built-in installations. Pop in the plastic
snap bushing found in hardware kit into
the hole left by supply cord/strain relief.
Continued
1. Install a snap bushing found in hard-
ware kit into one of the holes found on
rear of valve cover shield. The other
hole is for a strain relief clamp (not
For Built-In Installation
WARNING: A licensed elec-
trician must connect the wiring
harness to electrical supply fol-
lowing all local codes. Electri-
cian must provide a clamp on
the box cover to secure the wir-
ing. Wiring should be routed
through the bushing in the hole
on the outer casing of heater.
supplied) to secure incoming electrical 4. A licensed electrician must follow the
supply.
wiring diagram to connect incoming
electrical supply to fan kit wiring har-
ness (see Figure 20).
2. Follow steps 2 through 6 in Installing
Blower Assembly, pages 11 and 12.
Also remove black wire from middle 5. Plug power cord to the outlet receptacle
switch terminal 2.
(not provided) as shown in figure 19.
Wind the extra cable in power cord and
and tie it up with the plastic wire strap
(see Figure 19). Set the cable bundle
between the burner bracket and outer
casing, away from the burner.
6. Reinstall valve cover shield.
Blower Bracket
Assembly
7. Test to make sure the blower is work-
ing properly.
Screw
8. Reinstall upper louver assembly and
hood if previously removed, (see Figure
15, page 11). Close lower louver door.
Fan Switch
(Auto/Off/On)
Auto
1
2
Off
3
Thermostat
Switch
(N.O.)
Blue
On
Blue
110/115
V.A.C.
Red
Blower
Motor
Black
Red
White
Green
Switch
Wire
Harness
White
Green
Power
Cord
Figure 20 - Wiring Diagram For Blower
Accessory Built-In Installation
Outlet
Receptacle
3
2
1
Extension Cord
Red
Use extension cord if needed. The cord must
have a three-prong, grounding plug and a
three-hole receptacle. Make sure cord is in
good shape. It must be heavy enoughto carry
the current needed. An undersized cord will
cause a drop in line voltage. This will result
in loss of power and overheating. Use a No.
16 AWG cord for lengths less than 50 feet.
Blue
Switch Plate
Plastic Wire
Strap
Valve
Cover
Shield
Box Cover
Wire
Harness
Clamp Connector
(not included)
Figure 19 - Installing Blower Bracket Assembly
Continued
104407
13
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
Installation must include a manual shutoff
INSTALLATION
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
yourlocalcodes. Usepipeof1/2"
or greater diameter to allow
proper gas volume to fireplace. If
pipe is too small, undue loss of
pressure will occur.
valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
fireplace (see Figure 23).
Continued
Attaching Wood Base to Solid
Floor
IMPORTANT: Install main gas valve
(manual shutoff valve) in an accessible
location. The main gas valve is for turning
on or shutting off the gas to the appliance.
For attaching base to solid floors (concrete
or masonry)
Note: Floor anchors and mounting screws
areinhardwarepackage.Thehardwarepack-
age is provided with fireplace.
Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.
External Regulator
1. Drill holes at marked locations using
5/16" drill bit. For solid floors (concrete
or masonry), drill at least 1" deep.
Propane/LP
Supply Tank
2. Fold floor anchor as shown in Figure 21.
CAUTION:Usepipejointseal-
ant that is resistant to liquid pe-
troleum (LP) gas.
3. Insert floor anchor (wings first) into
hole. Tap anchor flush to floor.
4. Insert mounting screws through base
and into floor anchors.
We recommend that you install a sediment
trap in supply line as shown in Figure 23.
Locate sediment trap where it is within
reach for cleaning. Install in piping system
betweenfuelsupplyandheater.Locatesedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into fireplace controls. If sediment
trap is not installed or is installed wrong,
fireplace may not run properly.
5. Tighten screws until base is firmly fas-
tened to floor.
Vent Pointing Down
Figure 22 - External Regulator with Vent
Pointing Down
Figure 21 - Folding Anchor
CONNECTING TO GAS
SUPPLY
Approved Flexible
Gas Line
A.G.A. Design-Certified Manual
Shutoff Valve With 1/8" NPT Tap*
WARNING: A qualified ser-
vice person must connect fire-
place to gas supply. Follow all
local codes.
From
CAUTION:Neverconnectfire-
place directly to the propane/LP
supply. This fireplace requires
an external regulator (not sup-
plied). Install the external regula-
torbetweenthefireplaceandpro-
pane/LP supply.
External
Regulator
(11" W.C.
to 14" W.C.
Pressure)
3" Minimum
The installer must supply an external regu-
lator. The external regulator will reduce
incoming gas pressure. You must reduce
incoming gas pressure to between 11 and
14 inches of water. If you do not reduce
incoming gas pressure, fireplace regulator
damage could occur. Install external regu-
lator with the vent pointing down as shown
in Figure 22. Pointing the vent down pro-
tects it from freezing rain or sleet.
Pipe Nipple Cap Tee Joint
Sediment Trap
Figure 23 - Gas Connection
* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer.
See Accessories, page 27.
104407
14
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
INSTALLATION
Continued
Screen
Shipping
Screw
CONNECTING FIREPLACE
TO GAS SUPPLY
Branch Support
Installation Items Needed
Shoulder
Screw
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not
provided)
1. Remove fireplace screen. Remove two
screws that hold fireplace screen in
place for shipping. These screws are
located near top of screen. Discard
screws. Lift fireplace screen up and pull
out to remove.
Flexible
Gas Line
2. Remove screws that attach branch sup-
port to fireplace (see Figure 24). Care-
fully lift up branch support and remove
from fireplace (see Figure 24).
Screen
3. Route flexible gas line (provided by
installer) from manual shutoff valve
into fireplace through side or rear ac-
cess holes in outer casing. Route flex-
ible gas supply line through fireplace
access holes in outer casing.
Figure 24 - Removing Branch Support From Fireplace
To Fireplace
Gas Regulator
NOTICE: Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
fromthefireplace(seeFigure24).
The flexible gas supply line con-
nection to the manual shutoff
valve should be accessible.
Gas Connector
Manual Shutoff Valve
To
External
Regulator
Flexible Gas Line from
Flexible Gas Line from
Fireplace Gas Regulator
Provided With Fireplace
Manual Shutoff Valve
Provided By Installer
4. Apply pipe joint sealant lightly to male
threads of gas connector attached to
flexible gas line (see Figure 25). Con-
nect flexible gas line to flexible gas line
attached to gas regulator of fireplace
(see Figure 25).
Figure 25 - Attaching Flexible Gas Lines Together
5. Check all gas connections for leaks. See
Checking Gas Connections, page 16.
6. Replace branch support back into fire-
place. Feed flexible gas line into fire-
place base area while replacing branch
support. Make sure the entire flexible
gas line is in fireplace base area. Reat-
tach branch support to fireplace with
screws removed in step 2.
Continued
104407
15
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
TestPressuresEqualToorLessThan
1/2 PSIG
Pressure Testing Fireplace Gas
Connections
1. Open manual shutoff valve (see Figure
26).
INSTALLATION
Continued
1. Close manual shutoff valve (see Fig-
ure 26).
CHECKING GAS
CONNECTIONS
2. Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.
2. Open propane/LP supply tank valve.
3. Make sure control knob of fireplace is
in the OFF position.
WARNING: Test all gas pip-
ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.
3. Check all joints from propane/LP sup-
ply tank to manual shutoff valve (see
Figure 27). Apply mixture of liquid
soap and water to gas joints. Bubbles
forming show a leak.
4. Check all joints from manual shutoff
valve to thermostat gas valve (see Fig-
ure 27). Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.
WARNING:Neveruseanopen
flame to check for a leak. Apply a
mixture of liquid soap and water
toalljoints.Bubblesformingshow
a leak. Correct all leaks at once.
4. Correct all leaks at once.
5. Correct all leaks at once.
6. Light fireplace (see Operating Fire-
place, pages 17 and 18). Check all other
internal joints for leaks.
Manual
Shutoff
Open
Valve
7. Turn off fireplace (see To Turn Off Gas
to Appliance, page 18).
CAUTION: Make sure external
regulator has been installed be-
tweenpropane/LPsupplyandfire-
place. See guidelines under Con-
necting To Gas Supply, page 14.
8. Replace front panel.
Closed
Figure 26 - Manual Shutoff Valve
Pressure Testing Gas Supply
Piping System
TestPressuresInExcessOf1/2PSIG
1. Disconnect fireplace and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of 1/2
psig will damage fireplace regulator.
Propane/LP
Supply Tank
Manual
Shutoff
Valve
2. Cap off open end of gas pipe where
manual shutoff valve was connected.
3. Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.
4. Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.
5. Correct all leaks at once.
6. Reconnect fireplace and manual shutoff
valve to gas supply. Check reconnected
fittings for leaks.
Figure 27 - Checking Gas Joints Shown with Optional Mantel
104407
16
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Note: You may be running this fire-
place for the first time after hooking
up to gas supply. If so, the control
knob may need to be pressed in for
30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up
when released, contact a qualified
service person or gas supplier for
repairs.
LIGHTING
INSTRUCTIONS
OPERATING
FIREPLACE
FOR YOUR SAFETY
WARNING: You must operate
this fireplace with the fireplace
screen in place. Make sure fire-
place screen is installed before
running fireplace.
READ BEFORE
LIGHTING
WARNING: If you do not fol-
low these instructions exactly, a
fireorexplosionmayresultcaus-
ing property damage, personal
injury or loss of life.
NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell.Openwindowtoventsmell.
Operate fireplace on HI position
to burn off odor. This will only
last a few hours.
6. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the front of burner. If needed, keep
pressing ignitor button until pilot
lights.
A. This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly.
Note: If pilot does not stay lit, refer
to Troubleshooting, pages 20 through
22. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure, page 18.
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.
1. STOP! Read the safety information,
column 1.
2. Make sure manual shutoff valve is
fully open.
3. Turn control knob clockwise
to the OFF position.
WHAT TO DO IF YOU SMELL
GAS
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
4. Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation. If you don’t smell gas, go
to the next step.
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
seconds, release control knob.
Note: If pilot goes out, repeat steps
3 through 7. This fireplace has a
safety interlock system. Wait one (1)
minute before lighting pilot again.
5. Turn control knob counterclockwise
to the PILOT position. Press
in control knob for five (5) seconds
(see Figure 28).
8. Turn control knob counterclockwise
to desired heating level. The
main burner should light. Set control
knob to any heat level between HI
and LO.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.
Ignitor Button
Control Knob
CAUTION:Donottrytoadjust
heating levels by using the
manual shutoff valve.
D. Do not use this appliance if any part
has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.
Ignitor Electrode
Thermocouple
Pilot Burner
Figure 28 - Control Knob In The OFF
Position
Figure 29 - Pilot
(Actual Pilot May Vary From Illustration)
Continued
104407
17
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under Light-
OPERATING
FIREPLACE
Continued
ing Instructions, page 17.
2. With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1. Turn control knob clockwise
to the OFF position.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, page 17.
2. Turn off all electric power to the ap-
pliance if service is to be performed.
OPERATING BLOWER
Shutting Off Burner Only (pilot
stays lit)
This blower has three settings: ON, OFF,
andAUTO.IntheONposition,theblower
will operate constantly. In the OFF posi-
tion, the blower will not operate. In the
AUTOposition,theblowerwillstartwhen
thethermostatsensesasufficientincrease
in firebox temperature.
Turn control knob clockwise
the PILOT position.
to
THERMOSTAT
CONTROL
OPERATION
Note: Your fireplace and thermostat
blower will not turn on and off at the
same time. The fireplace may run for
several minutes before the blower turns
on.Aftertheheatermodulatestothepilot
position, the blower will continue to run.
The blower will shut off after the firebox
temperature decreases.
The thermostat used on this fireplace
senses the room temperature. At times
the room may exceed the set tempera-
ture. If so, the burner will shut off. The
burner will cycle back on when room
temperature drops below the set tem-
perature.
The control knob can be set to any heat
level between HI and LO.
Note: It is safe to operate fireplace with
blower turned off. However, the blower
helps distribute heated air from the
fireplace.
Note: The thermostat sensing bulb mea-
sures the temperature of air near the
fireplace cabinet. This may not always
agree with room temperature (depend-
ing on housing construction, installation
location, room size, open air tempera-
tures, etc.). Frequent use of your fire-
place will let you determine your own
comfort levels.
Auto/Off/On Switch
Figure 30 - Auto/Off/On Switch
104407
18
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
BURNER FLAME PATTERN
INSPECTING
BURNER
Figure 33 shows a correct burner flame
pattern. Figure34showsanincorrectburner
Check pilot flame pattern and burner flame flame pattern. The incorrect burner flame
pattern often.
pattern shows the flame consistently higher
than one inch above the log.
PILOT FLAME PATTERN
Ifburnerflamepatternisincorrect,asshown
in Figure 34
Figure 31 shows a correct pilot flame pat-
tern. Figure 32 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the fireplace will shut
down.
• turn fireplace off (see To Turn Off Gas to
Appliance, page 18)
• see Troubleshooting, pages 20 through 22
Top of Flame About
One Inch Below Logs
If pilot flame pattern is incorrect, as shown
in Figure 32
• turn fireplace off (see To Turn Off Gas to
Appliance, page 18)
• see Troubleshooting, pages 20 through 22
Thermocouple
Pilot Burner
Figure 33 - Correct Burner Flame Pattern
Top of Flame Consistently About
One Inch Higher Than Logs
Figure 31 - Correct Pilot Flame Pattern
(Actual Pilot May Vary From Illustration)
Figure 34 - Incorrect Burner Flame Pattern
Pilot Burner
Thermocouple
Figure 32 - Incorrect Pilot Flame Pattern
(Actual Pilot May Vary From Illustration)
104407
19
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
TROUBLESHOOTING
Note: For additional help, visit DESA
International’stechnicalservicewebsite
WARNING: Turn off and un-
plug fireplace and let cool before
servicing. Only a qualified ser-
vice person should service and
repair fireplace.
CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot.ThiscandamageODS/
pilot unit.
Note:Alltroubleshootingitemsarelistedin
order of operation.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no 1. Ignitor cable pinched or wet
spark at ODS/pilot
1. Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry
2. Reconnect ignitor cable
2. Ignitor electrode not connected to igni-
tor cable
3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode broken
6. Ignitor electrode positioned wrong
3. Replace ignitor cable
4. Replace piezo ignitor
5. Replace ignitor
6. Replace ignitor
When ignitor button is pressed, there is 1. Gas supply turned off or manual shutoff
1. Turn on gas supply or open manual
shutoff valve
spark at ODS/pilot but no ignition
valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in
PILOT position
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT
position
4. Air in gas lines when installed
4. Continue holding down control knob. Re-
peat igniting operation until air is removed
5. Contact local propane/LP gas company
6. Clean ODS/pilot (see Cleaning and
Maintenance, page 23) or replace ODS/
pilot assembly
5. Depleted gas supply
6. ODS/pilot is clogged
7. Gas regulator setting is not correct
7. Replace gas regulator
ODS/pilot lights but flame goes out when 1. Control knob not fully pressed in
1. Press in control knob fully
control knob is released
2. Control knob not pressed in long enough
2. After ODS/pilot lights, keep control
knob pressed in 30 seconds
3. Safety interlock system has been triggered
3. Wait one minute for safety interlock sys-
tem to reset. Repeat ignition operation
4. Fully open manual shut-off valve
5. Hand tighten until snug, then tighten 1/4
turn more
4. Manual shutoff valve not fully open
5. Thermocouple connection loose at con-
trol valve
6. Pilot flame not touching thermocouple,
which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
6. A) Contact local propane/LPgas company
B) Clean ODS/pilot (see Cleaning and
Maintenance, page 23) or replace ODS/
pilot assembly
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot
7. Thermocouple damaged
8. Control valve damaged
7. Replace thermocouple
8. Replace control valve
104407
20
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
1. Burner orifice is clogged
1. Clean burner (see Cleaning and Mainte-
nance, page 23) or replace burner orifice
2. Replace burner orifice
2. Burner orifice diameter is too small
3. Inlet gas pressure is too low
3. Contact local propane/LP gas company
Delayed ignition of burner
1. Manifold pressure is too low
2. Burner orifice is clogged
1. Contact local propane/LP gas company
2. Clean burner (see Cleaning and Mainte-
nance, page 23) or replace burner orifice
Burner backfiring during combustion
1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Mainte-
nance, page 23) or replace burner orifice
2. Replace burner pressure
2. Burner damaged
3. Low inlet gas pressure
4. Gas regulator defective
3. Contact local propane/LP gas company
4. Replace gas regulator
Slight smoke or odor during initial operation 1. Residues from manufacturing processes 1. Problem will stop after a few hours of
operation
Fireplace produces a whistling noise when 1. Air in gas line
burner is lit
1. Operate burner until air is removed from
line. Have gas line checked by local pro-
pane/LP gas company
2. Air passageways on fireplace blocked
2. Observe minimum installation clearances
(see pages 8 through 10)
3. Dirty or partially clogged burner orifice 3. Clean burner (see Cleaning and Mainte-
nance, page 23) or replace burner orifice
Whitepowderresidueformingwithinburner 1. When heated, vapors from furniture pol- 1. Turn heater off when using furniture
box or on adjacent walls or furniture
ish, wax, carpet cleaners, etc. turn into
white powder residue
polish, wax, carpet cleaners, or similar
products
Continued
104407
21
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediatelycallyourgassupplierfromaneighbor’sphone. Followthe
gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT:Operatingfireplacewhereimpuritiesinairexistmaycreateodors.Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Fireplace produces a clicking/ticking noise 1. Metal expanding while heating or con- 1. This is common with most fireplaces. If
just after burner is lit or shut off
tracting while cooling
noise is excessive, contact qualified ser-
vice person
Fireplace produces unwanted odors
1. Fireplace burning vapors from paint, hair 1. Ventilate room. Stop using odor caus-
spray, glues, etc. (See IMPORTANT
statement above)
ing products while fireplace is running
2. Low fuel supply
2. Refill supply tank
3. Gas leak. SeeWarning statement at 3. Locate and correct all leaks (see Check-
top of page
ing Gas Connections, page 16)
Fireplace shuts off in use (ODS operates)
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Open window and/or door for ventilation
2. Contact local propane/LP gas company
3. Clean ODS/pilot (see Cleaning and
Maintenance, page 23)
Gas odor even when control knob is in OFF 1. Gas leak. SeeWarning statement at 1. Locate and correct all leaks (see Check-
position
top of page
ing Gas Connections, page 16)
2. Control valve defective
2. Replace control valve
Gas odor during combustion
1. Foreign matter between control valve 1. Take apart gas tubing and remove for-
and burner eign matter
2. Gas leak. SeeWarning statement at 2. Locate and correct all leaks (see Check-
top of page
ing Gas Connections, page 16)
Moisture/condensationnoticedonwindows 1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Venti-
lation requirements (page 5)
104407
22
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
4. Check the injector holder located at the
end of the burner tube again. Remove
any large particles of dust, dirt, lint, or
pet hairs with a soft cloth or vacuum
cleaner nozzle.
CLEANING AND
MAINTENANCE
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
WARNING: Turn off fireplace
and let cool before cleaning.
• burner will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply may be low
5. Blow air into the primary air holes on
the injector holder.
6. In case any large clumps of dust have
now been pushed into the burner repeat
steps 3 and 4.
CAUTION:Youmustkeepcon-
trol areas, burner, and circulating
air passageways of fireplace
clean. Inspect these areas of fire-
place before each use. Have fire-
place inspected yearly by a quali-
fiedserviceperson.Fireplacemay
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.
When Gas Quality Is Bad
• pilot will not stay lit
Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air • fireplace will backfire when lit
• burner will produce flames and soot
inlet hole about two inches from where the
Youmayfeelyourgaspressureistoolowor
pilot flame comes out of the pilot assembly
gas quality is bad. If so, contact your local
(see Figure 36). With the unit off, lightly
propane/LP gas supplier.
blow air through the air inlet hole. You may
blowthroughadrinkingstrawifcompressed
air is not available.
TECHNICAL
Injector Holder
SERVICE
CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE
You may have further questions about in-
stallation, operation, or troubleshooting.
Ports/Slots
The primary air inlet holes allow the proper
amount of air to mix with the gas. This
provides a clean burning flame. Keep these
holesclearofdust, dirt, andlint. Cleanthese
air inlet holes prior to each heating season.
Blocked air holes will create soot. We rec-
ommend that you clean the unit every 2,500
hours of operation or every three months.
If so, contact DESA International’s Techni-
cal Service Department at 1-800-323-5190.
You can also visit DESA International’s
technical services web site at
Burner
Tube
Primary Air Inlet
Holes
Figure 35 - Injector Holder On Outlet
Burner Tube
Wealsorecommendthatyoukeeptheburner
tube and pilot assembly clean and free of
dustanddirt.Tocleanthesepartswerecom-
mend using compressed air no greater than
30 PSI. Your local computer store, hard-
ware store, or home center may carry com-
pressed air in a can. You can use a vacuum
cleaner in the blow position. If using com-
pressed air in a can, please follow the direc-
tions on the can. If you don't follow direc-
tions on the can, you coulddamage the pilot
assembly.
Pilot Air Inlet
Hole
Pilot Assembly
Figure 36 - Pilot Inlet Air Hole
CABINET
1. Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.
Air Passageways
2. Inspect burner, pilot, and primary air
inlet holes on injector holder for dust • Use a vacuum cleaner or pressurized air
to clean.
and dirt (see Figure 35).
3. Blow air through the ports/slots and
holes in the burner.
Exterior
• Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabi-
net to remove dust.
104407
23
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
ILLUSTRATED
3
PARTS
1
17
BREAKDOWN
9
VMH10TPA
29
7
44
4
43
10
43
8
3
3
2
11
4
32
42
4
14
25
24
28
20
12-1
23
43
31
13
36
14
34
38
33
19
39
37
41
25
5
12
6
24
18
38
35
15
12-1
12-2
27
22
40
26
21
16
30
104407
24
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
KEY
NO.
VMH10TPA
PART NO.
PARTS LIST
DESCRIPTION
QTY.
VMH10TPA
1
2
3
4
5
6
7
8
102633-02CK
102624-02
099230-02
098304-01
103591-02
103209-03
102635-02CK
104058-01
103209-01
101712-04
102638-01
099059-02
098514-01
098594-01
102460-01CJ
099211-01
103963-01
103671-01
100587-01
098303-02
104335-01CK
102649-02CJ
099415-04
102875-01
101381-01
099387-03
098271-06
M11084-38
101004-13
098522-15
102639-01
101628-01
102869-01
102731-01
103295-01CJ
104078-01
104313-01
104313-02
M10908-2
Outer Casing Top
Outer Casing
Shoulder Screw
Screw, #10 x 3/8"
Burner
Louvered Door
Left and Right Side Front
Branch
Brass Top Louver
Firebox Hood
1
1
14
12
1
1
2
1
1
1
1
1
1
1
1
2
1
1
4
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
2
1
1
2
1
31
1
This list contains replaceable parts used in
your fireplace. When ordering parts, follow
the instructions listed under Replacement
Parts on page 26 of this manual.
9
10
11
12
12-1
12-2
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Firebox Top
ODS/Pilot Assembly
Thermocouple
Ignitor Electrode
Firebox Wrapper
Control Bracket Screw
Inlet Tube
Burner Tube
Brass Screw, #6 x 3/8
Regulator Screw
Outer Shell Base
Branch Support
Gas Regulator
Regulator Bracket
Valve Cover and Piezo
Pilot Tube
Ignitor Cable
Screw #8 x 3/8"
Injector
Gas Valve
Baffle
Flexible Connector
Control Bracket
Control Shield
Screen Assembly
Main Log
Pin Hinge (Right)
Pin Hinge (Left)
Hinge Screws
Burner Support
Pilot Bracket
3/8 NPT x 3/8" Flare Brass Fitting
Nut, M5
Bushing
Hex Head Screw, #10 x 3/8"
Middle Rail
103734-01
101006-01
097809-03
098249-01
101629-02
M11084-26
102458-01CK
PARTS AVAILABLE — NOT SHOWN
104319-02
101054-01
100563-01
103470-01
Instructional Video
Lighting Instructions Plate
Warning Plate
1
1
1
1
Hardware Package
104407
25
Download from Www.Somanuals.com. All Manuals Search And Download.
®
VMH10TPA
VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
SPECIFICATIONS
Type Gas
Input Rate
10,000 Btu/Hr
Propane/LP Only
Piezo
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (in. of water)*
Maximum
8.5" W.C.
14"
11"
Minimum
Dimensions, Inches (H x W x D)
Fireplace (including hood and screws)
Carton
25 7/8 x 26 13/16 x 9 3/8
32 5/8 x 27 3/16 x 11 5/8
Weight, pounds
Fireplace
Shipping
44 1/2 lbs.
48 lbs.
* For purposes of input adjustment
REPLACEMENT
PARTS
Note: Use only original replacement parts.
Thiswillprotectyourwarrantycoveragefor
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) call DESA International’s Technical
Service Department at 1-800-323-5190 for
referral information.
WhencallingDESAInternational,haveready
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LPor natural gas)
• purchase date
Usually, we will ask you to return the defec-
tive part to the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s) call DESA International’s Parts De-
partment at 1-800-972-7879 for referral in-
formation.
WhencallingDESAInternational,haveready
• model number of your fireplace
• the replacement part number
104407
26
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
ACCESSORIES
CABINET MANTEL WITH
BUILT-IN HEARTH BASE AND
ROUNDED LEG STYLING
Unfinished - GM921U
Purchase these fireplace accessories from
your local dealer. If they cannot supply these
accessories call DESA International’s Sales
Department at 1-800-458-2472 for referral
information. You can also write to the ad-
dress listed on the back page of this manual.
Finished - GM920F
For use with fireplace. A hardwood mantel
and hearth base offers compact styling and
completes the fireplace look. Available in a
walnut finished or an unfinished hardwood,
ready to stain or paint. Complete assembly
instructionsincluded.Three-sidedbrasstrim
kit included.
MANUAL SHUTOFF VALVE
GA5010
Manual shutoff valve with 1/8" NPT tap.
CABINET MANTEL WITH
BUILT-IN HEARTH BASE
AND TRADITIONAL SQUARE
LEG STYLING
Unfinished - GM923U
Finished - GM922F
For use with fireplace. A hardwood mantel
and hearth base offers compact styling and
completes the fireplace look. Available in a
stained or an unfinished (ready to stain or
paint) Oak Veneer over hardwood. Com-
pleteassemblyinstructionsincluded.Three-
sided brass trim kit included.
BRASS TRIM KIT - GA6095
Optional four-sided brasstrim kit forrecessed
built-ininstallations(whenunitisraisedoffof
the floor. Provides a finished appearance by
covering rough edges of wall opening.
BRASS TRIM KIT - GA6094
Optional three-sided brass trim kit for cus-
tom and recessed installations (when unit is
on the floor). Provides a finished appear-
ance by covering rough edges of wall open-
ing. Included with all mantels.
CORNER MANTEL WITH
BUILT-IN HEARTH BASE
Unfinished - GM721U
Finished - GM720F
Forusewithfireplace. Space-savingmantel
andhearthbasecornerdesignfeaturesclean,
classic lines. Available in a walnut finish or
an unfinished hardwood, ready to stain or
paint. Complete assembly instructions in-
cluded. Three-sided brass trim kit included.
THERMOSTATICALLY -
CONTROLLED BLOWER KIT
GA3400T
Providesbetterheatdistribution.Makesfire-
place more efficient. Automatically turns
off and on as needed.
104407
27
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written
warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
VENT-FREE PROPANE/LP GAS COMPACT CLASSIC HEARTH® FIREPLACE
DESA International warrants this product to be free from defects in materials and components for four (4) years and five (5) years
on stainless steel burners from the date of first purchase, provided that the product has been properly installed, operated and
maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check
must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this
fireplacetoproperoperatingconditionandanallowanceforlaborwhenprovidedbyaDESAAuthorizedServiceCenter.Warranty
part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory
replacement parts. Failure to use original factory replacement parts voids this warranty. The fireplace MUST be installed by a
qualified installer in accordance with all local codes and instructions furnished with the unit.
Thiswarrantydoesnotapplytopartsthatarenotinoriginalconditionbecauseofnormalwearandtear,orpartsthatfailorbecomedamaged
as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor,
transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE
PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND
LIMITSTHEDURATIONOFANYANDALLIMPLIEDWARRANTIES,INCLUDINGWARRANTIESOFMERCHANTA-
BILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS AND FIVE (5)
YEARS ON STAINLESS STEEL BURNERS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S
LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL
SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or
consequentialdamages, sotheabovelimitationonimpliedwarranties, orexclusionorlimitationondamagesmaynotapplytoyou.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
INTERNATIONAL
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
104407-01
REV. D
01/00
104407 01
NOT A UPC