Power-Tech .1 Series
Power-Tech 1.1
Power-Tech 2.1
Power-Tech 3.1
Operation Manual
Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your
local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000.
This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible
situation which may arise during installation, operation or maintenance.
The information provided in this manual was deemed accurate as of the publication date. However, updates to this information may have
occurred. To obtain the latest version of this manual, please visit the Crown website at www.crownaudio.com.
Trademark Notice: Crown, Amcron and ODEP are registered trademarks of Crown International. Grounded Bridge is a trademark of
Crown International. Other trademarks are the property of their respective owners.
Some models may be exported under the name Amcron.®
©2002 by Crown Audio, Inc. P.O. Box 1000, Elkhart, Indiana 46515-1000 U.S.A. Telephone: 574-294-8000
132800-2
2/02
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
Table of Contents
5 Advanced Features and Options ......................................... 13
5.1 Protection Systems .................................................... 13
5.1.1. ODEP ................................................................. 13
5.1.2 Ultrasonic and Radio Frequency Protection. 13
5.1.3 Drive Protection................................................ 13
5.1.4 Transformer Thermal Protection.................... 13
5.1.5 Fuses and Circuit Breakers.............................. 13
5.2 Option ........................................................................... 14
5.2.1 MT-BB................................................................. 14
6 Troubleshooting ...................................................................... 15
7 Specifications ......................................................................... 16
8 Service ..................................................................................... 17
8.1 Worldwide Service ...................................................... 18
8.2 US and Canada Service .............................................. 18
8.2.1 Service at a US or Canada Service Center............. 18
8.2.2 Factory Service ..................................................... 18
8.2.3 Factory Service Shipping Instructions................... 18
9 Warranty .................................................................................. 19
Factory Service Information Form ........................................... 21
Important Safety Instructions .............................................. 2
Table of Contents ................................................................. 3
1 Welcome ................................................................................... 4
1.1 Features.......................................................................... 4
2 How to Use This Manual ....................................................... 4
3 Setup.......................................................................................... 5
3.1 Unpack Your Amplifier ............................................... 5
3.2 Install Your Amplifier .................................................. 5
3.3 Ensure Proper Cooling ............................................... 5
3.4 Choose Input Wire and Connectors ......................... 6
3.5 Choose Output Wire and Connectors ...................... 7
3.6 Wire Your System ....................................................... 8
3.6.1 Stereo Mode...................................................... 8
3.6.2 Bridge-Mono Mode .......................................... 8
3.6.3 Parallel-Mono Mode......................................... 8
3.7 Set Input Sensitivity .................................................. 9
3.8 Connect to AC Mains .................................................. 9
3.9 Startup Procedure ....................................................... 9
4 Operation ................................................................................. 9
4.1 Precautions .................................................................. 9
4.2 Front Panel Controls and Indicators ......................... 10
4.3 Back Panel Controls and Connectors............................. 11
Operation Manual
page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
2 How to Use This
Manual
1 Welcome
•
•
Safe with any load. Bridge-Mono and
Parallel-Mono modes make it easy to opti-
mize the amplifier’s performance for a wide
range of loads.
Congratulations on purchasing a Crown
Power-Tech™.1 Series amplifier. Power-Tech .1
Series amplifiers are compact, professional
power amplifiers engineered to meet the most
demanding sound reinforcement needs. They
compare very favorably to more expensive
amplifiers, providing uncolored sound and sig-
nal-to-noise ratios commonly associated with
recording studios.
This manual provides you with the necessary
information to safely and correctly set up and
operate your amplifier. It does not cover every
aspect of installation, setup or operation that
might occur under every condition. For addi-
tional information, please consult Crown’s
Amplifier Application Guide (available online at
Support, your system installer or retailer.
Complete protection against shorted out-
puts, mismatched loads, overheating,
input/output DC and high-frequency over-
load; full internal fault protection.
•
•
Balanced phone jack inputs in parallel with
XLR input connectors. Barrier block input
connectors are optional.
Modern power amplifiers are sophisticated
pieces of engineering capable of producing
extremely high power levels. They must be
treated with respect and correctly installed if
they are to provide the many years of reliable
service for which they were designed.
Backed by the industry’s ONLY three-year,
no-fault, fully transferable and extendable
warranty.
We strongly recommend you read all instruc-
tions, warnings and cautions contained in this
manual. Also, for your protection, please send
in your warranty registration card today. And
save your bill of sale—it’s your official proof of
purchase.
In addition, the Power-Tech .1 Series amplifiers
include a number of features which require
some explanation before they can be used to
their maximum advantage.
Please take the time to study this manual so
that you can obtain the best possible service
from your amplifier.
1.1 Features
•
The patented ODEP circuitry and
Grounded Bridgedesign combine to pro-
vide performance and reliability that sur-
pass all traditional designs.
page 4
Operation Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
3 Setup
3.3 Ensure Proper Cooling
3.2 Install Your Amplifier
3.1 Unpack Your Amplifier
When using an equipment rack, mount units
directly on top of each other. Close any open
spaces in rack with blank panels. DO NOT
block front or rear air vents. The side walls of
the rack should be a minimum of 2 inches (5.1
cm) away from the amplifier sides, and the back
of the rack should be a minimum of 4 inches
(10.2 cm) from the amplifier back panel.
CAUTION: Before you begin, make sure
your amplifier is disconnected from the
power source, with power switch in the
“off” position and all level controls
turned completely down (counterclock-
wise).
Please unpack and inspect your amplifier for
any damage that may have occurred during
transit. If damage is found, notify the transpor-
tation company immediately. Only you can ini-
tiate a claim for shipping damage. Crown will
be happy to help. Save the shipping carton as
evidence of damage for the shipper’s inspec-
tion.
Use a standard 19-inch (48.3-cm) equipment
rack. See Figure 3.1 for amplifier dimensions.
Figure 3.2 illustrates standard amplifier airflow.
We also recommend that you save all packing
materials so you will have them if you ever
need to transport the unit. Never ship the
unit without the factory pack.
You may also stack amps without using a cabi-
net.
NOTE: When transporting, amplifiers should be
supported at both front and back.
YOU WILL NEED (not supplied):
•
•
Input wiring cables
Output wiring cables
Rack for mounting amplifier (or a stable surface
for stacking)
WARNING: Before you start to set up
your amplifier, make sure you read and
observe the Important Safety Instruc-
tions found at the beginning of this man-
ual.
Figure 3.1 Dimensions
Figure 3.2 Airflow
Operation Manual
page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
3 Setup
3.4 Choose Input Wire
and Connectors
Crown recommends using pre-built or profes-
sionally wired, balanced line (two-conductor
plus shield), 22-24 gauge cables and connec-
tors. If you chose the MT-BB input barrier strip
option, use bare wire or spade lugs at the ampli-
fier inputs. Otherwise use either 3-pin male XLR
connectors or TRS ¼-inch phone connectors.
Figure 3.3 shows connector pin assignments for
balanced wiring, and Figure 3.4 shows connec-
tor pin assignments for unbalanced wiring.
NOTE: Custom wiring should only be per-
formed by qualified personnel.
Figure 3.3 Balanced Input
Connector Wiring
Figure 3.4 Unbalanced Input
Connector Wiring
page 6
Operation Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
3 Setup
3.5 Choose Output Wire and Con-
nectors
Crown recommends using pre-built or profes-
sionally wired, high-quality, two-conductor,
heavy gauge speaker wire. Use bare wire, a dual
banana plug or spade lugs on the amplifier end
of each speaker cable (Figure 3.5). To prevent
the possibility of short-circuits, wrap or other-
wise insulate exposed loudspeaker cable con-
nectors.
Using the guidelines below, select the appropri-
ate size of wire based on the distance from
amplifier to speaker.
Distance
up to 25 ft.
26-40 ft.
Wire Size
16 gauge
14 gauge
12 gauge
10 gauge
8 gauge
41-60 ft.
Figure 3.5 Output Connector Wiring
61-100 ft.
101-150 ft.
151-250 ft.
6 gauge
CAUTION: Never use shielded cable for
output wiring.
Operation Manual
page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
3 Setup
3.6 Wire Your System
3.6.3 Parallel-Mono Mode
Turn down the Level controls (fully counter-
clockwise) and turn off the amplifier before wir-
ing it as described below. Refer to Figure 3.6.
CAUTION: Parallel-Mono wiring requires
installation of a jumper wire. Do not
switch to Stereo or Bridge-Mono mode
until this output jumper wire is removed.
3.6.1 Stereo Mode
IMPORTANT: The Channel 2 IOC indicator
will remain lit when operating in Paral-
lel-Mono mode.
Set the back panel stereo/mono switch to Stereo.
INPUTS: Connect input wiring to both channels.
Set the back panel stereo/mono switch to
Parallel-Mono.
OUTPUTS: Maintain proper polarity (+/–) on
output connectors.
INPUTS: Connect input wiring to Channel 1
only.
Connect Channel 1 positive (+) speaker load to
Channel 1 positive terminal of amp; repeat for
negative (–). Repeat Channel 2 wiring as for
Channel 1.
OUTPUTS: Add a 14 AWG gauge (or larger)
jumper between the red(+) Channel 1 and Chan-
nel 2 binding posts. Connect the speaker posi-
tive (+) lead to the Channel 1 red (+) terminal.
Connect the speaker negative (–) lead to the
Channel 1 black (–) terminal.
3.6.2 Bridge-Mono Mode
Set the back panel stereo/mono switch to
Bridge-Mono.
INPUTS: Connect input wiring to Channel 1
only.
NOTE: Use only the Channel 1 level con-
trol.
OUTPUTS: Connect the speaker across the posi-
tive terminals of each channel. Do not use the
negative terminals when the amp is being oper-
ated in Bridge-Mono mode.
NOTE: Crown provides a reference of wiring pin
assignments for commonly used connector
types in the Crown Amplifier Application Guide,
NOTE: The Channel 2 level control should
be set fully counter-clockwise when oper-
ating the amplifier in Bridge-Mono mode.
Figure 3.6 Three System Connection Methods
page 8
Operation Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
3 Setup
3.8 Connect to AC Mains
3.7 Set Input Sensitivity
4 Operation
4.1 Precautions
Your amplifier is protected from internal and
external faults, but you should still take the fol-
lowing precautions for optimum performance
and safety:
Connect your amplifier's power cord to the AC
mains power source (power outlet).
The input sensitivity switch inside the amplifier
is set to 0.775 volt RMS at the factory. (Factory
setting for international models is 1.4V). It can
be changed to 1.4 volts or a voltage gain of 26
dB. The 26 dB gain setting is equivalent to a
sensitivity of 2.1 volts for the Power-Tech 1.1,
2.6 volts for the Power-Tech 2.1 and 3.3 volts
for the Power-Tech 3.1.
WARNING: The third prong of this con-
nector (ground) is an important safety
feature. Do not attempt to disable this
ground connection by using an adapter
or other methods.
1. Before use, configure your amplifier for
proper operation as described in the Setup sec-
tion of this manual. Improper wiring can result
in serious operating difficulties. For advanced
setup techniques, consult Crown's Amplifier
Application Guide available online at
Amplifiers don't create energy. The AC mains
voltage and current must be sufficient to deliver
the power you expect. You must operate your
amplifier from an AC mains power source with
not more than 10% variation above or below
the amplifier's specified line voltage and within
the specified frequency requirements (indicated
on the amplifier's back panel label). If you are
unsure of the output voltage of your AC mains,
please consult your electrician.
To change the input sensitivity:
1. Turn off and unplug the amplifier from the
AC source.
2. Remove the input module on the back panel.
3. Locate the labeled access hole for the sensi-
tivity switch (Figure 3.7). The sensitivity switch
will not be visible because it is mounted below
the hole. Use your little finger to reach it.
2. Use care when making connections, select-
ing signal sources and controlling the output
level. The load you save may be your own!
3. Do not short the ground lead of an output
cable to the input signal ground. This may form
a ground loop and cause oscillations.
4. Set the switch to the desired position.
5. Replace the input module.
3.9 Startup Procedure
Use the following procedure when first turning
on your amplifier:
4. Never connect the output to a power supply,
battery or power main. Electrical shock may
result.
1. Turn down the level of your audio source.
2. Turn down the Level controls of the amplifier.
5. Tampering with the circuitry, or making
unauthorized circuit changes may be hazardous
and invalidates all agency listings.
3. Turn on the Power switch. The Enable indica-
tor next to the Power switch should glow.
6. Do not operate the amplifier with the IOC
LED constantly flashing yellow.
4. Turn up the level of your audio source to an
optimum level.
7. Do not overdrive the mixer, which will cause
clipped signal to be sent to the amplifier. Such
signals will be reproduced with extreme accu-
racy, and loudspeaker damage may result.
5. Turn up the Level controls on the amplifier
until the desired loudness or power level is
achieved.
6. Turn down the level of your audio source to
its normal range.
8. Do not operate the amplifier with less than
the rated load impedance. Due to the amplifier's
output protection, such a configuration may
result in premature clipping and speaker
damage.
If you ever need to make any wiring or installa-
tion changes, don't forget to disconnect
the power cord.
Figure 3.7 Input Sensitivity Switch
For help with determining your system's opti-
mum gain structure (signal levels) please refer
to the Crown Amplifier Application Guide,
Crown is not liable for damage that results from
overdriving other system components.
Operation Manual
page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
4 Operation
4.2 Front Panel Controls and Indicators
C. Enable Indicator
Enable indicator shows the on/off status of the low-
voltage supply.
The diagram below explains the controls and indicators
on the front panel of the Power-Tech .1 Series.
D. Power Switch
A. Level Controls
Power switch (and circuit breaker for the Power-Tech
1.1, Power-Tech 2.1 and 220/240 VAC Power-Tech
3.1).
Continuously variable level controls for each channel.
B. SPI/IOC Indicator
Dual-function indicator for each channel flashes green
for signal presence (SPI) and yellow if any distortion
exceeds 0.05% (IOC).
E. Ventilation Grille
Removable grille and dust filter.
Figure 3.8 Power-Tech .1 Series Front Panel Controls and Indicators
page 10
Operation Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
CTs Multi-Channel Power Amplifiers
4 Operation
4.3 Back Panel Controls and Connec-
tors
G. Reset Switch
Circuit breaker reset switch (100/120 VAC Power-Tech
3.1 only)
The diagram below explains the controls and connec-
tors on the back panel of the Power-Tech .1 Series.
H. Power Cord
F. Stereo/mono Switch
Stereo/mono switch for selecting Stereo, Bridge-Mono
or Parallel-Mono modes.
I. XLR Input Connectors
Balanced XLR connectors for input.
J. 1/4-inch Input Connectors
1/4-inch balanced phone jacks for input.
Figure 3.9 Power-Tech .1 Series Back Panel Controls and Connectors
Operation Manual
page 11
Download from Www.Somanuals.com. All Manuals Search And Download.
CTs Multi-Channel Power Amplifiers
This page intentionally left blank.
page 12
Operation Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
5 Advanced Features
and Options
5.1.4 Transformer Thermal
Protection
5.1.2 Ultrasonic and Radio Fre-
quency Protection
NOTE: For detailed information about
these Crown amplifier features, please
consult the Crown Amplifier Application
Guide, available on the Crown website
This activates in the rare case where the unit's
transformer temperature rises to unsafe levels.
Then the amplifier will remove power to the
high-voltage transformer. The fan will continue
to run in all units except those with 220/240
VAC transformers. The amplifier will return to
normal after it cools to a safe temperature.
An amplifier's slew rate only needs to be large
enough to deliver the maximum voltage at the
highest required frequency. Higher slew rates
actually let the amplifier reproduce undesirable
frequencies. By design, Power-Tech .1 Series
amplifiers have a controlled slew rate to put a
frequency limit on the highest frequencies that
they reproduce. This limit occurs well above 20
kHz, so there is no audible effect on perfor-
mance. This approach protects the amplifier
from radio frequencies and can even protect
some sensitive loads (including some tweet-
ers).
5.1 Protection Systems
Your Crown amplifier provides extensive pro-
tection systems, including ODEP, ultrasonic/RF
protection, drive protection, transformer ther-
mal protection and fuses or circuit breakers to
protect the power supplies.
Your amplifier is designed to keep working
under conditions where other amplifiers would
fail. But even when you exceed the limits of a
Power-Tech .1 Series amplifier, it still protects
itself — and your investment — from damage.
5.1.1 ODEP
Crown invented ODEP to prevent amplifier
shutdown during demanding operation, and to
increase the efficiency of the output circuitry.
5.1.5 Fuses and Circuit Breakers
5.1.3 Drive Protection
Your amplifier's low-voltage power supply is
protected by an internal fuse, and its high-volt-
age power supplies are protected by a circuit
breaker. The circuit breaker is built into the
power switch for all Power-Tech 1.1, Power-
Tech 2.1 and 220/240 VAC Power-Tech 3.1
amplifiers. The circuit breaker is located on the
back panel of 100/120 VAC Power-Tech 3.1
amplifiers.
This system temporarily removes output drive
to protect the amplifier and its loads. Drive pro-
tection can be activated in two situations. First,
if dangerous subsonic frequencies or direct
current (DC) is detected in the amplifier's out-
put, drive protection will activate. The amplifier
resumes normal operation when it no longer
detects dangerous output. Activating this pro-
tection is very unlikely, but improper source
signals like infrasonic square waves or a
severely clipped input signal can activate this
system.
To do this, Crown measured the safe operating
area (SOA) of each output transistor before
installing it in an amplifier. Next, Crown
designed intelligent circuitry to simulate the
instantaneous operating conditions of those
output transistors. Its name describes what it
does: Output Device Emulation Protection or
ODEP. In addition to simulating output transis-
tor operating conditions, it compares their
operation to their known SOA. If ODEP sees
that more power will be asked of the output
devices than they can deliver, ODEP immedi-
ately limits the drive level until it falls within the
SOA. Limiting is proportional and kept to an
absolute minimum—only what is required to
prevent output transistor damage. Under nor-
mal conditions, no limiting is required and
ODEP is transparent to the audio signal.
With rated loads and output levels, the circuit
breaker will shut down the amplifier only in the
rare instance of a catastrophic amplifier failure.
Other protection systems such as ODEP keep
the amplifier operational under most other
severe conditions. The breaker can also shut
down the amplifier if extremely low-impedance
loads and high output levels result in current
draw that exceeds the breaker rating.
Second, the amplifier's fault protection system
puts the affected channel into drive protection
mode in rare situations where heavy common-
mode current is detected in its output. The
amplifier should never output heavy common-
mode current unless its circuitry is damaged.
Activating drive protection helps prevent further
damage.
Operation Manual
page 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
5 Advanced Features
and Options
Again, this should be possible only when oper-
ating outside rated conditions, as when the
amplifier is used to drive a 1-ohm load, or
when driving a severely clipped signal.
A Power-Tech .1 Series amplifier will not blow
its fuse or trip its breaker unless something is
wrong. In the rare event that an internal fuse
blows, please refer the unit to a qualified tech-
nician. If a breaker trips, try to identify and cor-
rect the problem before resetting the breaker.
The breaker for the Power-Tech 1.1 and 2.1 can
be reset using the front panel power switch. The
circuit breaker for a Power-Tech 3.1 can be
reset using the back panel reset switch. If the
problem persists, refer the unit to an authorized
Crown Service Center.
5.2 Option
5.2.1 MT-BB
The MT-BB is an accessory panel that provides
barrier strip input connectors. An MT-BB
accessory might be desirable in applications
requiring bare wire or spade lug connections.
Like other unused input connectors on your
Power-Tech .1 Series amplifier, these barrier
strip connectors can be used to daisy chain an
input signal from one amplifier to another.
-
C H - 2 I N P U T
C H - 1 I N P U T
MT BB
–
+
–
+
Important: The MT-BB must be installed
at a Crown Factory Service Center or the
Crown factory.
page 14
Operation Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
6 Troubleshooting
CONDITION: No power to the
amplifier.
CONDITION: No sound.
POSSIBLE REASON:
POSSIBLE REASON:
•
The amplifier has just been turned on and is
still in the 4-second turn-on delay.
•
•
The amplifier's Power switch is off.
The amplifier is not plugged into the power
receptacle.
•
The amplifier is in drive protection mode. This
can occur with improper source signals like
infrasonic square waves or input overloads
that excessively clip the input signal.
•
The amplifier's low-voltage power supply fuse
has blown. Return amp to Crown or an autho-
rized Crown Service Center for servicing.
•
The breaker has tripped. First disconnect your
speakers from the affected channel(s) one by
one to determine if one of the loads is shorted.
Reset the breaker and apply an input signal. If
the signal presence indicator flashes, then try a
different speaker or cable to determine where
the short is occurring. If no short can be found,
turn off the amp and allow the amp to cool. If
indicators do not return to normal after restart-
ing your amp, return amp to Crown or an
CONDITION: Distorted sound.
POSSIBLE REASON:
authorized Crown Service Center for servicing.
•
Input signal level is too high. Turn down your
amplifier level controls. NOTE: Your amplifier
should never be operated at a level which
causes the IOC LEDs to flash yellow con-
stantly.
•
•
•
Input signal level is very low.
Level controls are turned down.
Input cables are not connected.
Key
Off
Lit
Green Lit
Yellow Lit
Operation Manual
page 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
7 Specifications
Minimum Guaranteed Power
Power-Tech 1.1
Power-Tech 2.1
Power-Tech 3.1
120 VAC, 60 Hz Units, Stereo mode, per channel, both channels driven
1 kHz with 0.1% THD
Stereo, 4 ohms per ch.
Stereo, 8 ohms per ch.
305
220
460
325
760
540
120 VAC, 60 Hz Units, Bridge mono mode
1 kHz with 0.1% THD
8 ohms
16 ohms
605
445
910
660
1,525
1,090
120 VAC, 60 Hz Units, Parallel mono mode
1 kHz with 0.1% THD
2 ohms
4 ohms
605
440
920
655
1,530
1,080
Performance
Power-Tech 1.1
0.1 dB
Power-Tech 2.1
0.1 dB
Power-Tech 3.1
0.1 dB
Frequency Response (at 1 watt, 20Hz - 20 kHz)
Phase Response (at 1 watt, 10Hz - 20 kHz)
10°
10°
10°
Signal to Noise Ratio below rated power (20 Hz to 20 kHz)
Total Harmonic Distortion (THD) at rated power, from 20 Hz to 1 kHz
Total Harmonic Distortion (THD) at rated power, at 20 kHz
>100 dB
< 0.05%
< 0.1%
>100 dB
< 0.05%
< 0.1%
>100 dB
< 0.05%
< 0.1%
Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1,
from 163 milliwatts to full bandwidth power
< 0.05%
< 0.05%
< 0.05%
Damping Factor: 10 Hz to 400 Hz
>1000
> 60 dB
>1000
> 60 dB
>1000
> 60 dB
Crosstalk (below rated power, 20 Hz to 1 kHz)
Controlled Slew Rate
>13 volts/ms
20 k ohms, 10 k ohms
>13 volts/ms
20 k ohms, 10 k ohms
>13 volts/ms
20 k ohms, 10 k ohms
Input Impedance nominally balanced, nominally unbalanced
Load Impedance (Note: Safe with all types of loads)
Stereo
Bridge Mono
Parallel Mono
4-8 ohms
8-16 ohms
2-4 ohms
4-8 ohms
8-16 ohms
2-4 ohms
4-8 ohms
8-16 ohms
2-4 ohms
Voltage Gain (at maximum level setting)
0.775V sensitivity
1.4V sensitivity
35 dB
30 dB
36 dB
31 dB
38 dB
33 dB
Required AC Mains (configured country-specific)
Power Draw at Idle (configured country-specific)
50/60 Hz, 100-240VAC (+10%, -15%)
90 watts or less
50/60 Hz, 100-240VAC (+10%, -15%)
90 watts or less
50/60 Hz, 100-240VAC (+10%, -15%)
90 watts or less
page 16
Operation Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
7 Specifications
Performance (continued)
Power-Tech 1.1
Power-Tech 2.1
Power-Tech 3.1
AC Line Current
100 and 120 VAC units
220 and 240 VAC units
6 A
3 A
10 A
5 A
15 A
7 A
Ventilation
Cooling
Flow-through ventilation from
front to side panels
Flow-through ventilation from
front to side panels
Flow-through ventilation from
front to side panels
Internal heat sinks with forced-air cooling
for rapid, uniform heat dissipation
Internal heat sinks with forced-air cooling for
rapid, uniform heat dissipation
Internal heat sinks with forced-air cooling for
rapid, uniform heat dissipation
Dimensions
Width
EIA Standard 19-inch (48.3 cm) rack mount
(EIA RS-310-B)
EIA Standard 19-inch (48.3 cm) rack mount
(EIA RS-310-B)
EIA Standard 19-inch (48.3 cm) rack mount
(EIA RS-310-B)
Height
Depth
3.5 inches (8.9 cm
16 inches (40.6 cm)
3.5 inches (8.9 cm
16 inches (40.6 cm)
3.5 inches (8.9 cm
16 inches (40.6 cm)
Weight (120VAC, 60 Hz units)
Net Weight
Shipping Weight
30 lb (13.6 kg)
34 lb (15.4 kg)
33 lb (15.0kg)
37 lb (16.8kg)
36 lb 8 oz (16.6 kg)
40 lb 8 oz (18.4 kg)
Weight (International units)
Net Weight
Shipping Weight
31 lb 2 oz (14.1 kg)
34 lb 9 oz (15.7 kg)
35 lb 12 oz (16.9 kg)
38 lb 13 oz (17.6 kg)
37 lb 3 oz (16.6 kg)
40 lb 16 oz (18.6 kg)
Operation Manual
page 17
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
8 Service
shipping pack, however we still recom-
mend using a Crown Supplied Shipping
Container. Minimum recommended
requirements for materials are as follows:
275 P.S.I. burst test Double-Wall carton
that allows for 2-inch solid Styrofoam on
all six sides of unit or 3 inches of plastic
bubble wrap on all six sides of unit;
securely seal the package with an adequate
carton sealing tape. Do not use light boxes
or "peanuts." Damage caused by poor
packing cannot be covered under warranty.
8.2.2 Factory Service
Crown amplifiers are quality units that rarely
require servicing. Before returning your unit for
servicing, please contact Crown Factory Ser-
vice to verify the need for servicing.
To obtain factory service, fill out the service
information page found in the back of this man-
ual and send it along with your proof of pur-
chase and the defective unit to the Crown
factory.
This unit has very sophisticated circuitry which
should only be serviced by a fully trained tech-
nician. This is one reason why each unit bears
the following label:
For warranty service, we will pay for ground
shipping both ways in the United States. Con-
tact Crown Factory Service to obtain prepaid
shipping labels prior to sending the unit. Or, if
you prefer, you may prepay the cost of ship-
ping, and Crown will reimburse you. Send cop-
ies of the shipping receipts to Crown Factory
Service to receive reimbursement.
CAUTION: To prevent electric shock, do
not remove covers. No user serviceable
parts inside. Refer servicing to a quali-
fied technician.
4. Do not ship the unit in any kind of cabinet
(wood or metal). Ignoring this warning
may result in extensive damage to the unit
and the cabinet. Accessories are not
8.1 Worldwide Service
Service may be obtained from an authorized
service center. (Contact your local Crown/
Amcron representative or our office for a list of
authorized service centers.) To obtain service,
simply present the bill of sale as proof of pur-
chase along with the defective unit to an autho-
rized service center. They will handle the
necessary paperwork and repair.
Your repaired unit will be returned via UPS
ground. Please contact us if other arrange-
ments are required.
needed-do not send the product documen-
tation, cables and other hardware.
If you have any questions, please contact
Crown Factory Service.
8.2.3 Factory Service Shipping
Instructions:
Crown Factory Service
1718 W. Mishawaka Rd.,
Elkhart, Indiana 46517 U.S.A.
1. Before sending a Crown product to the
factory for service, first call the Crown
Factory Service for a return authorization
(RA) number.
Remember to transport your unit in the original
factory pack.
Telephone: 574-294-8200
800-342-6939 (North America,
Puerto Rico, and Virgin Islands only)
2. Be sure to fill out the service information
form that follows and enclose it with your
shipment, either inside the box or in a
packing slip envelope securely attached to
the outside of the shipping carton. Do not
send the service information form sepa-
rately. If you are sending the unit from a
Shipping Center, we recommend taping
the form to the product. We also recom-
mend recording the serial number and
model before shipping for your reference.
8.2 US and Canada Service
Service may be obtained in one of two ways:
from an authorized service center or from the
factory. You may choose either. It is important
that you have your copy of the bill of sale as
your proof of purchase.
Facsimile:
574-294-8301 (Technical Support)
574-294-8124 (Factory Service)
Internet:
8.2.1 Service at a US or Canada
Service Center
This method usually saves the most time and
effort. Simply present your bill of sale along
with the defective unit to an authorized service
center to obtain service. They will handle the
necessary paperwork and repair. Remember to
transport the unit in the original factory pack. A
list of authorized service centers in your area
can be obtained from the Crown website at
Factory Service.
3. To ensure the safe transportation of your
unit to the factory, ship it in an original
factory packing container. If you don't have
the original carton, you may obtain a prod-
uct service foam-in-place shipping pack
from the Crown Factory Service at the
number listed below. For non-warranty
service, you may also provide your own
page 18
Operation Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
9 Warranty
UNITED STATES & CANADA
SUMMARY OF WARRANTY
est, insurance, closing costs, and other finance
charges less a reasonable depreciation on the
product from the date of original purchase. War-
ranty work can only be performed at our autho-
rized service centers or at the factory. Warranty
work for some products can only be performed at
our factory. We will remedy the defect and ship
the product from the service center or our factory
within a reasonable time after receipt of the defec-
tive product at our authorized service center or
our factory. All expenses in remedying the defect,
including surface shipping costs in the United
States, will be borne by us. (You must bear the
expense of shipping the product between any for-
eign country and the port of entry in the United
States including the return shipment, and all
taxes, duties, and other customs fees for such for-
eign shipments.)
FROM ANY DEFECT IN THE NEW CROWN
PRODUCT. THIS INCLUDES ANY DAMAGE TO
ANOTHER PRODUCT OR PRODUCTS RESULT-
ING FROM SUCH A DEFECT. SOME STATES DO
NOT ALLOW THE EXCLUSION OR LIMITATIONS
OF INCIDENTAL OR CONSEQUENTIAL DAM-
AGES, SO THE ABOVE LIMITATION OR EXCLU-
SION MAY NOT APPLY TO YOU.
Crown International, 1718 West Mishawaka Road,
Elkhart, Indiana 46517-4095 U.S.A. warrants to
you, the ORIGINAL PURCHASER and ANY SUB-
SEQUENT OWNER of each NEW Crown product,
for a period of three (3) years from the date of
purchase by the original purchaser (the “warranty
period”) that the new Crown product is free of
defects in materials and workmanship. We further
warrant the new Crown product regardless of the
reason for failure, except as excluded in this War-
ranty.
WARRANTY ALTERATIONS
No person has the authority to enlarge, amend, or
modify this Crown Warranty. This Crown War-
ranty is not extended by the length of time which
you are deprived of the use of the new Crown
product. Repairs and replacement parts provided
under the terms of this Crown Warranty shall
carry only the unexpired portion of this Crown
Warranty.
ITEMS EXCLUDED FROM THIS
CROWN WARRANTY
This Crown Warranty is in effect only for failure of
a new Crown product which occurred within the
Warranty Period. It does not cover any product
which has been damaged because of any inten-
tional misuse, accident, negligence, or loss which
is covered under any of your insurance contracts.
This Crown Warranty also does not extend to the
new Crown product if the serial number has been
defaced, altered, or removed.
HOW TO OBTAIN WARRANTY
SERVICE
DESIGN CHANGES
We reserve the right to change the design of any
product from time to time without notice and with
no obligation to make corresponding changes in
products previously manufactured.
You must notify us of your need for warranty ser-
vice within the warranty period. All components
must be shipped in a factory pack, which, if
needed, may be obtained from us free of charge.
Corrective action will be taken within a reason-
able time of the date of receipt of the defective
product by us or our authorized service center. If
the repairs made by us or our authorized service
center are not satisfactory, notify us or our autho-
rized service center immediately.
LEGAL REMEDIES OF PURCHASER
WHAT THE WARRANTOR WILL DO
THIS CROWN WARRANTY GIVES YOU SPECIFIC
LEGAL RIGHTS, YOU MAY ALSO HAVE OTHER
RIGHTS WHICH VARY FROM STATE TO STATE.
No action to enforce this Crown Warranty shall be
commenced after expiration of the warranty
period.
We will remedy any defect, regardless of the rea-
son for failure (except as excluded), by repair,
replacement, or refund. We may not elect refund
unless you agree, or unless we are unable to pro-
vide replacement, and repair is not practical or
cannot be timely made. If a refund is elected, then
you must make the defective or malfunctioning
product available to us free and clear of all liens
or other encumbrances. The refund will be equal
to the actual purchase price, not including inter-
DISCLAIMER OF CONSEQUENTIAL
AND INCIDENTAL DAMAGES
THIS STATEMENT OF WARRANTY SUPERSEDES
ANY OTHERS CONTAINED IN THIS MANUAL
YOU ARE NOT ENTITLED TO RECOVER FROM
US ANY INCIDENTAL DAMAGES RESULTING
FOR CROWN PRODUCTS.
12/01
Operation Manual
page 19
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
9 Warranty
WORLDWIDE EXCEPT USA & CANADA
SUMMARY OF WARRANTY
replacement, or refund. We may not elect refund
unless you agree, or unless we are unable to pro-
vide replacement, and repair is not practical or
cannot be timely made. If a refund is elected, then
you must make the defective or malfunctioning
product available to us free and clear of all liens
or other encumbrances. The refund will be equal
to the actual purchase price, not including inter-
est, insurance, closing costs, and other finance
charges less a reasonable depreciation on the
product from the date of original purchase. War-
ranty work can only be performed at our autho-
rized service centers. We will remedy the defect
and ship the product from the service center
within a reasonable time after receipt of the defec-
tive product at our authorized service center.
DISCLAIMER OF CONSEQUENTIAL AND
INCIDENTAL DAMAGES
Crown International, 1718 West Mishawaka Road,
Elkhart, Indiana 46517-4095 U.S.A. warrants to
you, the ORIGINAL PURCHASER and ANY SUB-
SEQUENT OWNER of each NEW Crown1 product,
for a period of three (3) years from the date of pur-
chase by the original purchaser (the “warranty
period”) that the new Crown product is free of
defects in materials and workmanship, and we
further warrant the new Crown product regardless
of the reason for failure, except as excluded in this
Warranty.
YOU ARE NOT ENTITLED TO RECOVER FROM US
ANY INCIDENTAL DAMAGES RESULTING FROM
ANY DEFECT IN THE NEW CROWN PRODUCT.
THIS INCLUDES ANY DAMAGE TO ANOTHER
PRODUCT OR PRODUCTS RESULTING FROM
SUCH A DEFECT.
WARRANTY ALTERATIONS
No person has the authority to enlarge, amend, or
modify this Crown Warranty. This Crown Warranty
is not extended by the length of time which you are
deprived of the use of the new Crown product.
Repairs and replacement parts provided under the
terms of this Crown Warranty shall carry only the
unexpired portion of this Crown Warranty.
1
Note: If your unit bears the name “Amcron,” please substitute
it for the name “Crown” in this warranty.
ITEMS EXCLUDED FROM THIS CROWN-
WARRANTY
HOW TO OBTAIN WARRANTY SERVICE
You must notify your local Crown importer of
your need for warranty service within the warranty
period. All components must be shipped in the
original box. Corrective action will be taken within
a reasonable time of the date of receipt of the
defective product by our authorized service center.
If the repairs made by our authorized service cen-
ter are not satisfactory, notify our authorized ser-
vice center immediately.
This Crown Warranty is in effect only for failure of
a new Crown product which occurred within the
Warranty Period. It does not cover any product
which has been damaged because of any inten-
tional misuse, accident, negligence, or loss which
is covered under any of your insurance contracts.
This Crown Warranty also does not extend to the
new Crown product if the serial number has been
defaced, altered, or removed.
DESIGN CHANGES
We reserve the right to change the design of any
product from time to time without notice and with
no obligation to make corresponding changes in
products previously manufactured.
LEGAL REMEDIES OF PURCHASER
No action to enforce this Crown Warranty shall be
commenced after expiration of the warranty
period.
WHAT THE WARRANTOR WILL DO
We will remedy any defect, regardless of the rea-
son for failure (except as excluded), by repair,
THIS STATEMENT OF WARRANTY SUPERSEDES
ANY OTHERS CONTAINED IN THIS MANUAL FOR
CROWN PRODUCTS.
7/01
page 20
Operation Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
Crown Factory Service Information
Shipping Address: Crown International, Factory Service, 1718 W. Mishawaka Rd., Elkhart, IN 46517
Phone: 1-800-342-6939 or 1-574-294-8200 Fax: 1-574-294-8124
Owner’s Name : __________________________________________________________________________________________________________________________________________________________________
Shipping Address: ________________________________________________________________________________________________________________________________________________________________
Phone Number: ____________________________________Fax Number: _______________________________ Email:______________________________________________________________________________
Model: ____________________________________________________________________________________ Serial Number: _______________________________________________________________________
Purchase Date : __________________________________________________________________________________________________________________________________________________________________
NATURE OF PROBLEM
(Be sure to describe the conditions that existed when the problem occurred and what attempts were made to correct it.)
____________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________
Other equipment in system: ______________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________________________________________
If warranty has expired, payment will be:
Cash/Check
VISA
MasterCard
C.O.D.
Purchase Order for Crown Dealer
Card Number:______________________________________ Exp. Date:___________________
Signature:______________________________________________________________________
ENCLOSE THIS PORTION WITH THE UNIT. DO NOT MAIL SEPARATELY.
Operation Manual
page 21
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
page 22
Operation Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-Tech .1 Series Power Amplifiers
Operation Manual
page 23
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
|