Cres Cor Photo Scanner 120PH User Manual

Proof/Hot  
Cabinets  
FL-2306  
Rev. 7 (6/08)  
Page 1 of 4  
5925 Heisley Road • Mentor, OH 44060-1833  
OPERATING and MAINTENANCE INSTRUCTIONS  
Model: 120PH and 121PH “D” Series Proof/Hot Cabinets  
Model No.  
Volts  
Watts  
Amps  
Hertz  
Phase  
NEMA  
120PH1836D  
121PHUA11D  
121PH1818D  
120  
1920  
16.6  
60  
1
5-20P  
120PH1836D208  
121PHUA11D208  
121PH1818D208  
208  
240  
2000  
2000  
9.6  
8.6  
60  
60  
1
1
6-15P  
6-15P  
120PH1836D240  
121PHUA11D240  
121PH1818D240  
All are designed for AC service.  
HOW TO INSTALL UNIT:  
1. Place cabinet near warm ovens. Do NOT put in  
drafty areas or near ventilating systems.  
2. Plug cord end into proper wall outlet.  
Use of treated or  
soft water may be  
CONTROL PANEL PARTS IDENTIFICATION  
CAUTION  
required for proper  
operation and to maintain warranty.  
1. Switch - Power  
5. Yellow Light - Proof  
6. Red Light - Heat  
2. Yellow Light - Power  
3. Thermostat - Humidity  
4. Thermostat - Air  
3. Fill with 2 qts. (1.8 liters) of clean, hot water.  
7. Switch - Mode Selection  
8. Thermometer  
HOW TO PROOF:  
1. Fill water pan (See “How to Install”)  
2. Push “POWER” switch to “ON.” The yellow light  
will come on.  
NOTE: No. 8 setting will give you an approximate  
temperature of 95°F (35°C), and 90-95%  
humidity. Experiment with different  
“HUMIDITY” and “AIR” settings to get the  
exact temperature and humidity you need. The  
thermometer shows the temperature inside the  
cabinet.  
3. Push “MODE SELECTION” switch to “PROOF”.  
The yellow light will come on.  
4. Turn “HUMIDITY” dial to No. 8.  
5. Turn “AIR” dial to “OFF”.  
6. Preheat for 30 minutes.  
7. Put fresh or fully thawed dough into cabinet.  
NOTE: The cabinet temperature will drop temperature NOTE: Check water level in water pan if you are  
inside cabinet if cold dough is added.  
proong longer than 90 minutes. Fill with  
clean, hot water.  
Do NOT put frozen dough into cabinet  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Proof/Hot  
Cabinets  
FL-2306  
Rev. 7 (6/08)  
Page 3 of 4  
5925 Heisley Road • Mentor, OH 44060-1833  
OPERATING and MAINTENANCE INSTRUCTIONS  
Model: 120PH and 121PH “D” Series Proof/Hot Cabinets  
HOW TO CLEAN THE CABINET:  
The door is a polycarbonate panel in a powder coated frame.  
Use mild detergent and water, rinse and wipe dry with a soft cloth.  
The cabinet body (inside and outside) is aluminum.  
THIS CABINET BODY IS INTENDED TO BE CLEANED USING HIGH PRESSURE CLEANING METHODS.  
Wipe up spills as soon as possible and clean cabinet regularly to avoid heavy dirt build-up.  
Detergents will assist in removing dirt, grease and stains. Only use detergents recommended for pressure washers.  
Empty water pan at least once a week.  
TROUBLE-SHOOTING CHART:  
FAILURE  
POSSIBLE CAUSE  
1. Indicator lights do NOT light.  
1a. Circuit breaker/fuse to wall outlet is blown.  
1b. Cord is unplugged from wall outlet or cabinet.  
1c. Switch is “OFF”.  
2. Unit does not heat.  
2a. Thermostat set too low or is “OFF”.  
2b. Switch is “OFF”.  
3. Unit gets too hot or won’t shut off.  
4. Humidity is low  
3a. Defective electrical parts.  
UNPLUG UNIT FROM WALL OUTLET.  
4a. Water in pan may be low  
4b. Theremostat set too low  
5. Blower does not work or makes noise.  
5a. Defective blower.  
NOTE: Optional digital thermometer will ash if cabinet temperature is below 140°F or above 250°F.  
Call the factory if you need different settings.  
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Proof/Hot  
Cabinets  
FL-2306  
Rev. 7 (6/08)  
Page 4 of 4  
5925 Heisley Road • Mentor, OH 44060-1833  
OPERATING and MAINTENANCE INSTRUCTIONS  
Model: 130 and 131 “D” Series Hot Cabinets  
REPLACEMENT PARTS:  
DESCRIPTION  
Proof/Hot Unit (121PH)  
Proof/Hot Unit (120PH)  
Heater (Reservoir)  
Pan (Reservoir)  
120 VOLT  
PHU-747-071  
PHU-747-077  
0811-285  
208 VOLT  
PHU-747-072  
PHU-747-078  
0811-286  
240 VOLT  
PHU-747-073  
PHU-747-079  
0811-287  
1017-097  
1017-097  
1017-097  
Heater (Air)  
0811-214  
0811-250  
0811-215  
Thermostat Kit  
Thermometer Kit (Analog)  
Power Cord  
Proof & Heat Lights  
Power Light  
0848-062-K  
5238-030-K  
0810-065-1  
0766-093  
0848-062-K  
5238-030-K  
0810-039  
0766-093-1  
0766-095  
0848-062-K  
5238-030-K  
0810-039  
0766-093-1  
0766-095  
0766-094  
Switch (Power)  
0808-116  
0808-116  
0808-116  
Switch (Mode Selection)  
Blower Kit  
Drip Pan Kit  
0808-117  
0769-180-K  
1017-058  
0808-117  
0769-182-K  
1017-058  
0808-117  
0769-182-K  
1017-058  
Download from Www.Somanuals.com. All Manuals Search And Download.  

CompuSTAR Remote Starter CM4200DX User Manual
Craftsman Lawn Mower Accessory 61024610 User Manual
Cypress Computer Hardware CY62148ESL User Manual
Dacor Convection Oven ACTK27 User Manual
Danby Microwave Oven DMW111KSSDD User Manual
Dynex Network Card DX WGPUSB User Manual
Electro Voice Microphone N D468 User Manual
Fitness Quest Home Gym NBP01060 2 User Manual
GE Monogram Ice Maker ZDI15CBB User Manual
GE Monogram Refrigerator ZS48N User Manual