Filtered Water Inonizer
CPE-06ALW/B
•
•
•
This product can not be used if the voltage is different from
that mentioned in the rating plate.
For your safety and proper use of the product, please read this
User’s Manual before use.
Warranty card is included in this User’s Manual.
Download from Www.Somanuals.com. All Manuals Search And Download.
DEAR CUSTOMERS
Thank you for using our Filtered Water Inonizer.
Please read this Users’ Manual to use and maintain the product correctly. If you encounter a
problem while using the product, you may solve the problem referring to the User’s Manual.
As this manual contains the product warranty card, please keep it in a safe place.
This system (CPE-06AL) conforms to NSF/ANSI 42 for aesthetic chlorine and NSF/ANSI 53 for VOC
as verified and substantiated by test data.
See performance data sheet for individual contaminants and reduction performance.
CONTENTS
FOR INFORMATION
HOW TO USE
SAFETy iNFORmATiON. . . . . . . . . . . . . . . . . . . 3
Electricity safety . . . . . . . . . . . . . . . . . . . . . . . 3
Installation safety. . . . . . . . . . . . . . . . . . . . . . 4
Operation safety. . . . . . . . . . . . . . . . . . . . . . . 5
Others. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
iNSTAllATiON PRECAUTiONS . . . . . . . . . . .10
OPERATiON / iNdiCATiON PART . . . . . . . . .12
HOW TO USE. . . . . . . . . . . . . . . . . . . . . . . . . . . .15
To drink the cold ion water . . . . . . . . . . . . 15
To drink the ion water. . . . . . . . . . . . . . . . . 15
To drink the ambient water. . . . . . . . . . . . 15
To extract continuosly . . . . . . . . . . . . . . . . 16
PARTS NAmE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
WATER FilTRATiON PROCESS. . . . . . . . . . . . . 8
MAINTENANCE
OTHERS
iNSTAllATiON . . . . . . . . . . . . . . . . . . . . . . . . . .17
TROUblESHOOTiNG . . . . . . . . . . . . . . . . . . . .25
SPECiFiCATiON . . . . . . . . . . . . . . . . . . . . . . . . .27
WATER FlOW diAGRAm . . . . . . . . . . . . . . . . .28
PERFORmANCE dATA SHEET . . . . . . . . . . . .29
WARRANTy CARd. . . . . . . . . . . . . . . . . . . . . . .33
ClEANiNG mETHOd . . . . . . . . . . . . . . . . . . . .19
Storage tank. . . . . . . . . . . . . . . . . . . . . . . . . . 19
Gutter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
FilTER REPlACEmENT. . . . . . . . . . . . . . . . . . .22
FilTER REPlACEmENT mETHOd . . . . . . . . .23
2
- Please keep the User’s manual where it can be readily reached or found -
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETy INFORMATION
Be careful to keep this safety information.
Please read this information to prevent property loss and ensure your safety.
If not observed,
serious injury or
even death could
occur.
If not observed,
serious injury or
property damage
could occur.
If not observed, slight
injury or property
damage could occur.
Danger
Warning
Caution
Electricity safety
do not use a damaged
power cord or plug, and
loose outlet.
Otherwise, electric shock or
fire may occur as a result.
do not pull the power
cord.
Otherwise, electric shock or
fire may occur as a result.
do not carry the unit by
its power cord.
do not touch the power
plug with a wet hand.
Otherwise, electric shock or
fire may occur as a result.
Otherwise, electric shock or
fire may occur as a result.
do not forcefully bend
the power cord or put
it under a heavy object
to prevent it from being
damaged or deformed.
do not connect and
pull out the power plug
repeatedly.
Otherwise, electric shock or
fire may occur as a result.
Otherwise, electric shock or
fire may occur as a result.
if the electric outlet is
wet, carefully unplug the
unit and let the electric
outlet completely dry
before subsequent use.
Unplug the product
before repair, inspection,
or parts replacement.
Otherwise, electric shock or
fire may occur as a result.
Otherwise, electric shock or
fire may occur as a result.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Remove any dust or
water off in the pin and
contacts of the power
plug.
do not plug into an
outlet that is being
used by several other
appliances.
Otherwise, electric shock or
fire may occur as a result.
Use an electrical outlet
dedicated.
Otherwise, fire may occur as
a result.
When you don’t use for a
long time, close the main
water supply valve and
unplug.
Otherwise, electric shock or
fire may occur as a result.
do not attempt to repair
or modify the power cord
at your discretion.
Otherwise, electric shock or
fire may occur as a result.
in the case the power
cord is damaged, do
not replace the cord
yourself. Call Coway
Service Center to have it
replaced.
Otherwise, electric shock or
fire may occur as a result.
Installation safety
do not install near a
heating device.
Otherwise, fire may occur as
a result.
do not install the
product on a sloped
floor.
Injury to the user or damage
to the unit may result.
do not press the product
by constraint or impact.
Injury to damage to the unit
may result.
The filtration device installation shall
comply with applicable state and local
regulations.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETy INFORMATION
If not observed,
serious injury or
even death could
occur.
If not observed,
If not observed, slight
injury or property
damage could occur.
serious injury or
property damage
could occur.
Danger
Warning
Caution
Operation safety
When the water is
coming inside of the
product or there is a
puddle on the product,
call Service Center after
closing the supplying
valve and unplugging.
if our product produces a
strange noise or odd
smell, immediately
unplug from the
electrical outlet and call
our Service Center.
Otherwise, electric shock or
fire may occur as a result.
Otherwise, electric shock may
occur as a result.
do not put the candle, a
light for cigarette on the
products.
Otherwise, fire may occur as
a result.
do not place any
containers with water,
medicine, food, small
metallic objects, or any
flammable material on
the top of the product.
In the case foreign material
gets inside the product,
electric shock, fire, product
damage may occur as a result.
Use after closing the
water tank cover
completely inside of the
product.
To drink the filtered
water, change the filter
according to the filter
replacement cycle.
The buck or the foreign body
can be entered.
If you use the expired filter,
the filter performance is
lowered.
When you don’t use for
a long time, use after
draining the saved
water completely and
emptying the newly
ambient water once
again.
The saved water can be
polluted.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Danger Warning Caution
Others
Clean after unplugging.
Otherwise, electric shock or
fire may occur as a result.
do not clean by spraying
the water directly or
don’t wipe the product
using the benzene and
thinner.
Otherwise, electric shock or
fire may occur as a result.
do not repair,
do not use filtered water
for the water exchange
of an aquarium or a
fishbowl.
The ambient water through
the membrane isn’t suitable
for the fish’s life environment
as it removed the ionic
disassemble, or modify.
Otherwise, electric shock or
product damage may occur
as a result.
material. In some cases, fishes
might even die.
After moving the product
or replacing the inno-
sense filter, the black
powder can be remained
in the inner bottom of
the water tank.
do not use with water
that is microbiologically
unsafe or of unknown
quality without adequate
disinfection before or
after the ststem.
It is quiet harmless as the
powder of the activated
carbon used in the inno-sense
filter was flowed out for
improving the water tastes .
6
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS NAME
Front
Operation Part
Indication Part
Continuous Extraction Button
Ambient Water Extraction Lever
Front Draining Door
Ion Water Extraction Lever
Rear
Top Cover
Wire Condenser
Power Cord
Inlet(Orange) Tubing
Outlet(Blue) Tubing
7
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER FILTRATION PROCESS
The filter is the core technology of the filtration system.
If you don’t use qualifying filter or if you use an old filter that has expired, the system
performance may degrade.
The 5-step Water Filtering System(CPE-06AL)
Step 1 : PlUS SEdimENT FilTER
This plus sediment filter has the functions to reduce infusible particles from feed water and to
protect membrane and pre-carbon filter from being plugged.
Step 2 : PRE-CARbON FilTER
This pre-carbon filter has the function to reduce aesthetic chlorine, odor, volatile organic
compounds(VOC’s).
Step 3 : NF mEmbRANE FilTER
Step 4 : iNNO-SENSE FilTER
This inno-sense filter has the functions to reduce smell induction material and to improve taste of
water. It also has the function to reduce aesthetic chlorine, volatile organic compounds(VOC’s).
Step 5 : CERAmiC FilTER
PLUS SEDIMENT
FILTER
PRE-CARBON
FILTER
NF MEMBRANE
FILTER
INNO-SENSE
FILTER
CERAMIC
FILTER
CERAMIC
FILTER
Disposed
Water
Outlet
Uses of disposed water
-
The daily life water should be used for cleaning the restroom, the house, clothes, or
purposes other than drinking.
Tips
-
Never use the daily life water for a drinking water or a cook.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER FILTRATION PROCESS
The filter is the core technology of the filtration system.
If you don’t use qualifying filter or if you use an old filter that has expired, the system
performance may degrade.
The 6-step Water Filtering System(CPE-06AL)
Step 1 : PlUS SEdimENT FilTER
This plus sediment filter has the functions to reduce infusible particles from feed water and to
protect membrane and pre-carbon filter from being plugged.
Step 2 : PRE-CARbON FilTER
This pre-carbon filter has the function to reduce aesthetic chlorine, odor, volatile organic
compounds(VOC’s).
Step 3 : NF mEmbRANE FilTER
Step 4, 5 : FiNE POST-CARbON FilTER
This fine post-carbon filter has the functions to reduce smell induction material and to improve taste
of water. It also has the function to reduce aesthetic chlorine, volatile organic compounds(VOC’s).
Step 6 : CERAmiC FilTER
PLUS SEDIMENT
FILTER
PRE-CARBON
FILTER
NF MEMBRANE FINE POST-CARBON CERAMIC
FILTER FILTER FILTER
CERAMIC
FILTER
Disposed
Water
Outlet
Uses of disposed water
-
The daily life water should be used for cleaning the restroom, the house, clothes, or
purposes other than drinking.
Tips
-
Never use the daily life water for a drinking water or a cook.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION PRECAUTIONS
The summary for the proper installation of the water filtration device
1. Close main water supply valve to separate the faucet.
2. Wind the teflon tape on the adaptor and fit it to the
pipe.
do not turn the water pipe.
3. Connect the faucet with the adaptor.
Shall install the adaptor with connector on the cold water
pipe.
4. Connect 1/4 inch orange tubing with the connector
on the adaptor.
Flush water through each filter at least 5 minutes before
Connection.
5. Open the feed valve to supply water to the filtration
system.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION PRECAUTIONS
Please check before use!
This product is for 120 V~ 60 Hz only.
Please connect the power plug to a dedicated grounded electrical
outlet for 120 V~ 60 Hz. The water filtration device works normally
only when the electricity is connected.
• Open the main water supply valve.
• The main water must be supplied to operate the water filtration device normally.
• After installing the product
Get rid of the saved water above the full water in the inner water tank 2 times or more to use.
• When the indicator in the indication part is turned off
When the indicator in the indication part is turned off, check if the power supply was stopped
due to the power failure or other cause.
• Regularly filter replacement
It is important to replace the filter regularly to drink the pure water. If the filter is overused
beyond its service life, the performance of the water filtration device deteriorate, Do not miss the
filter replacement cycle.
• When you didn’t use for a long time
If you saved the water for a long time or you didn’t use, drain the water inside of the water
filtration device completely and remove the newly filtered water one time to use.
• When you don’t want to use for a long time
Close the main water supply valve and unplug.
When you don’t use for a long time, close the main water supply valve and unplug.
Tips
11
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION / INDICATION PART
Indication part/Operation part
Indication Part
Operation Part
Cooling mode
selection button
Ion water
button
Strong alkaline
water button
1
2
3
Weak alkaline
water button
Power
indicator
Cooling
indicator
Cleaning
indicator
4
1
2
4
Cold ion
water button
Continuous
extraction button
Low level
indicator
Check
indicator
5
6
3
5
1
2
4
Power indicator
Cooling indicator
If you connect the power,
the indicator is turned on.
The indicator blinks during
the continuous extraction.
When selecting cooling mode,
the indicator is turned on.
When cooling is complete, the
indicator is turned off.
3
5
low level indicator
If the water level of the
internal water tank is low,
the indicator is turned on.
Cleaning indicator
While cleaning the electrolysis
vessel, the indicator is turned
on.
Check indicator
If a problem occurs with the
product, the indicator is turned
on. In this case, please contact
our after-service center.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION / INDICATION PART
Operation part
1
2
Cooling mode
ion water button
selection button
Press this button to extract
ionized water. If you press
this button, the button is
turned on.
Press this button to select or
deselect cooling mode. This
button is turned on when
cooling mode is selected.
3
4
Strong alkaline water
button
Weak alkaline water
button
Press this button to extract
strong alkaline water. If you
press this button, the button
is turned on.
Press this button to extract
weak alkaline water. If you
press this button, the button
is turned on.
5
6
Cold ion water button
Continuous
Continuous
Extraction
extraction button
Press this button to extract
water continuously.
Press this button to extract
cold ionized water. If you press
this button, the button is
turned on.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
To use the cold water function
Press the cold mode button and confirm that the cold
mode button is turned on. If you want to turn off cold
mode, press and hold the button for about 3 seconds or
more.
You can drink cold ion water in about two hours after
turning the cold mode.
If no key is pressed for 1 minute after ionized
water has been extracted.
▶
Electrolysis vessel cleaning function
The auto electrolysis vessel cleaning function is provided
to keep the vessel clean and protect the product. During
electrolysis vessel cleaning, the cleaning indicator is
turned on.
De
vice
tion
F
iltra
er
Wat
or
requ
nerat
ce Ge
do
bstan
cal Su
Medi
ired.
i
s
a
ctor
n
wit
h
C
onsultatio
1 If no ionized water is extracted 1 minute after ionized
water is extracted, the vessel is cleaned automatically.
2 If the stop period exceeds 7 hours after water is
extracted, the vessel is cleaned automatically.
3 If about 30 minutes has passed after the power is
turned on and then cool mode is turned on, the vessel
If the stop period exceeds 7 hours after water
has been extracted.
▶
▶
is cleaned automatically
.
De
vice
tion
F
iltra
er
Wat
or
is req
nerat
octor
ce Ge
d
bstan
cal Su
Medi
Cons
.
uired
a
on
ultati
w
ith
If about 30 minutes has passed after cool mode
has been turned on.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
HOW TO USE
To drink cold ion water
Push high or low alkaline button. Then push cold ion water button. You can have cold ion water by
push extraction lever of cold ion water.
Devi
ce
ation
r
Filtr
Wate
c
e
G
e
n
erator
ctor is re
n
l
Substa
w
Medica
Consult
quired
.
ith
a
do
ation
Safety interruption feature: extraction stops automatically after 1 minute continuous
extraction.
If low level lamp is on, cold lon water is not extracted.
Tips
Ion water and cold ion water button is canceled automatically 10 seconds after
extraction.
According to environment or user’s drinking habit, the first cup maybe not cold enough.
but it is not product break down. However, you can have cold water from second cup.
To drink ion water
Choose high or low alkaline button. Then push ion water button. You can have ion water by push
extraction lever of ion water.
vice
ion De
Filtrat
Water
e
G
e
n
e
r
ator
c
Substan
Medical
r
e
q
u
i
r
e
d.
i
s
o
n
w
i
t
h
a
doctor
t
i
C
onsulta
Safety interruption feature: extraction stops automatically after 1 minute continuous
extraction.
If low level lamp is on, cold lon water is not extracted.
Tips
Ion water and cold ion water button is canceled automatically 10 seconds after
extraction.
To drink ambient water
You can have ambient water by push ambient water lever.
vice
on De
W
a ter
Filtrati
r
Generato
Medical
S
ubstance
ion with
o
c
t
o
r
i
s
required
.
a
d
C
onsultat
Safety interruption feature : if pushing the lever for 2
minutes continuously, extraction stops automatically.
Tips
15
Download from Www.Somanuals.com. All Manuals Search And Download.
To extract continuosly
To extract ionized water continuously
To extract filtrated water continuously
Lamp status
▶
▶
To extract ionized water continuously, press the strong or weak
alkaline button. Press the Ion water or cold mode button.(Make
sure to confirm that the required ion water selection button
is turned on.) If you press and hold the continuous extraction
button for about 2 seconds, you can receive the selected ion
water for about 1 minute.
When extracting water continuously, check if the ion water
and cold mode buttons are turned off. (If you press a button
that has been turned on again, the button is turned off.)
If you press and hold the continuous extraction button for
about 2 seconds, you can receive water for about 2 minutes
and 30 seconds.
One more push on continuous extraction button
stops continuous extraction.
Ion water and cold ion water button is
Tips
automatically canceled after 10 seconds.
- When the low water level indicator is turned on,
the ion or cold ion water is not extracted.
Continuous
extraction
Continuous
extraction botton
Button status
on
Cold ion water
Medical Substance Generator
Consultation with
a
doctor is required.
Water Filtration Device
on
Ion water
Medical Substance Generator
Consultation with
a
doctor is required.
Water Filtration Device
Push and hold for 2
seconds
DECO Lamp
flickering
on
Ambient water
Medical Substance Generator
Consultation with
a
doctor is required.
Water Filtration Device
16
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Follow the instruction for installation
Main water
supply valve
Cooling stopper
120 V~ 60 Hz Only
1
Connect the orange color inlet tubing to the tap water
2
supplying pipe. Connecting the outlet tubing
.
Inlet tubing (Orange)
Outlet tubing(Blue)
1
2
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Be cautious!
Water filtration device installation place 1
Please install the water filtration system not at a rough place, a damp
place, a place where the unit is exposed to the direct sunlight, a
place where dust is present, or a place that the water drops.
Water filtration device installation place 2
Please install at the place where it is 10 cm or more off from the wall
and the bottom is flat and firm.
After installing the water filtration system
Filtered water: Fill the water tank with the filtrated water and remove
the water twice or more if necessary after installing it.
Ion water: Fill the water tank with the ionized water and remove the
water twice or more if necessary after installing it.
Removing moisture: Remove moisture and dust from the operating,
display and connecting parts of the front cover.
Cold water plumbing
Cold water
plumbing
Please connect to the cold water pipe necessarily. (If you connect to
the warm water pipe, the filter can be damaged.)
movement and installation
When the position is moved, connect the power cord when 30
minutes passes after installing.
To maintain optimal product performance, consult a Coway engineer for the detailed
installation methods.
There may be some water remaining inside of the filter which was used to test the
product during inspection process at the factory.
Please feel at easy and use as it isn’t the used product.
Don’t reuse the main water supply valve and hose that was previously
used when you install the product.
Tips
18
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING METHOD
Storage tank
1. Turn it off by pressing the cold mode button
at the front panel of the product for about 3
seconds and unplug the power cord. Close the
main water supply valve.
Take care that water does not enter the product
other than through the water hose.
Tips
2. Please drain and store the water inside of the
water filtration device completely using the
draining hose.
Please drain and store the water inside of the
water filtration device completely using the
draining hose.
Tips
3. Slide the top cover of the product backwards, open the fixing latches of the
internal water tank, and then open the cover.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Separate the ceramic filter from the bottom of the cover of the internal
water tank and use the stored water to clean it.
5. Please wipe the surface of the storage tank
with a soft cloth.
6. drain the water completely
using the draining hose after
washing out the internal water
tank with the stored water.
You can drain the water within the internal water tank
completely by lowering the draining part cover at the
front and connecting the draining hose (the continuous
Tips
extraction hose).
7. After installing the ceramic filter at the bottom of the cover of the internal
water tank, close the internal water tank cover. lock the fixing latches of
the internal water tank and close the cover.
2
1
Because locking the fixing latch of the internal water tank incorrectly may cause the
alien substances or bacteria to enter, please make sure that the fixing latches are
locked correctly.
Tips
20
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING METHOD
8. Close the top cover, plug in the power cord and
open the water supply valve.
Close the storage tank cover completely.
A worm or a foreign body can be entered.
When you clean the storage tank, don’t use the medicine or the
detergent.
If you don’t clean the medicine or the detergent cleanly, it can be
harmful to the body.
Tips
-
Keep the surroundings cleanly and clean the storage tank once
per two months.
Gutter
1. Gutter separation method
The gutter can be separated easily with lifting up the front
part of the gutter and taking out.
2. Gutter assembling methods
Clean the gutter and then insert it into the groove at the
bottom of the front of the product slightly to install it..
21
Download from Www.Somanuals.com. All Manuals Search And Download.
FILTER REPLACEMENT
Filter
The life of the water filtration system is the filter. It it isn’t the legitimated
filter or you use too long even if it is the legitimated filter, the filter
performance can be lowered.
Please change to the legitimated filter according to the replacement cycle.
Filter replacement cycle
If the filter is not regularly replaced, it may degrade the water quality from the product. The filter
replacement cycle depending on the main water quality can be shortened
rater than the expected replacement cycle.
The period for the filter exchange is made based on 10 L use in a day for
house use(4 people based) and 20 L use for business.
CPE-06Al
Part No.
WJSF11-PLUS
WJCF8-PRE
WJMF11-NF
Names of Filter
Plus sediment fiter
Pre-carbon filter
Usable Period
6 months
12 months
12 months
NF membrane filter
WJIF11-S
/WJFCF11-POST
Inno-sense filter
/ Fine post-carbon filter
18 months
12 months
WJCC-02
Ceramic filter
About filter replacement cycle
The filter replacement cycle described above is not the filter quality
warranty period but the expected cycle (life) that the filter shows its
original performance.
Therefore, the filter replacement cycle may be reduced for the area with
the poor water quality or more application.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
FILTER REPLACEMENT METHOD
1. Close the main water supply valve after unplugging the power cord and
drain the water inside of the internal water tank of the water filtration
device (see p19).
2. Open the top cover and loosen the fixing screw at the top of the product.
Open the front cover and disconnect the connected cable completely.
- Open the top cover by sliding it backwards.
- Hold and pull the front cover in the direction of 1. Pull the front cover in the
Tips
direction of 3 while sliding the front cover in the direction of 2 to unlock the
latch in the center on the left. Unlock the latch on the right according to the same
method. Then the front cover is separated completely.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
3. After separating the fitting connected to the filter to replace, please
replace the filter.(Separate the fitting using the proper tool.)
By changing the filter and connecting the fitting and the hose precisely,
check that there is no leakage and drain the first filtered water necessarily.
Tips
4. Connect all the cables and close the front cover making sure to align the
groove. Fasten the fixing screw of the top of the product with a screw
driver and close the top cover.
1
2
3
Please be sure to use a new filter after cleansing.
-
-
Plus sediment filter: Install after cleaning with the main water for about 3 minutes.
Pre-carbon/Fine post carbon/Inno-sense filter: Please assemble it after cleansing
Tips
it with the water passed through
the plus sediment filter for about 3
minutes.
-
Membrane filter: Please assemble it after cleansing it with the water passed
through the plus-sediment filter and the pre-carbon filter for
about 3 minutes.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
The water filtration device may operate abnormally due to minor causes not because of the
product malfunction but because of the fact that the user is not familiar with the product use.
In such a case, problems can be solved easily even without the help from the Service Center by
checking the following items. If you can’t solve the problem after checking the following items,
please call the Service Center.
Symptom
Check
Measures to take
• Did you clean the internal water tank?
Clean the internal water tank.
Get rid of the saved water and clean the
internal water tank.
The water tastes odd.
•You didn’t use it for a long time.
Use ionized water only after extracting and
disposing of the water more than twice in
ionized water mode.
•Is it time to change the filter?
•The water is flowing slower.
Request a filter replacement.
Request a filter replacement.
Check if the power cord is plugged into a
120 V~ 60 Hz outlet.
•Is the power connected?
The water is flowing
slower.
•Did you close the main water supply valve?
Open the main water supply valve.
•Did the temperature of the main water drop
suddenly?
The amount of filtrated water decreases as
the temperature of the water drops.
Press the Cold Mode button so that it is
turned on.
•Is the Cold Mode button turned on?
•Is the Cooling indicator turned on?
There is no cold
water.
Cold Mode is in progress. Please use it in
1~2 hours.
•Is the back of the product too close to the
wall?
Keep the product away from the wall by at
least 10 cm.
• It may be time to change the filter.
Request a filter replacement.
• Is the water supply cut or is the water supply
valve closed?
Open the main water supply valve.
Water is not
In this case, please contact the After-
Service Center.
extracted or the
amount of water is
not correct.
•The level is incorrect.
• Is the draining or feed hose bent or folded?
• Is the feed hose too long?
Unfold the hose.
Keep the length of the feed hose equal to
or shorter than 5 m.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Symptom
Check
Measures to take
• Do you live in an area where the water
hardness is high?
The pH is subject to the region and the
quality of water.
Keep the height of the domestic water
outlet hose equal to or lower than 25 cm
from the bottom of the product.
The pH level is
incorrect.
• Is the height of the domestic water outlet
hose too high?
In this case, please contact the After-
Service Center.
• Is the amount of draining water small?
• Is the water being supplied actively?
• Is the power connected?
Check the water supply valve.
Check if the power cord is plugged into a
120V~ 60Hz outlet.
All operations were
stopped suddenly
while operating.
In this case, please contact the After-
Service Center.
• Is water overflowing or leaking?
• In this case, please contact the After-
Service Center.
The amount of filtrated water decreases as
the temperature of the water drops.
• Did the water flow out of the internal
water tank cover or from the inside of the
product?
Open the top cover to check where the
water is leaking, close the water supply
valve and contact the After-Service Center.
Water leaks.
Close the water supply valve and contact
the After-Service Center. The ionized water
extraction stops automatically.
• Water leaks when extracting ionized water.
• Ionized water extraction automatically
stops after 1 minute to prevent overflowing
by mistake.
There is insufficient water in the internal
water tank. In this case, use the water
within 1~2 hours.
Did the extraction time
exceed 1 minute?
Is the Low level indicator turned on?
There is insufficient water in the internal
water tank. In this case, use the water
within 1~2 hours.
• A white substance settles at the bottom
when ionized water is left over.
This is because of the separation of the
calcium mineral in the water depending on
the quality of the water. Although drinking
the water is safe, if this symptom continues,
ask your After-Sales Center how to protect
the product.
A white substance
settles at the bottom
when ionized water
is left over.
• Has the calcium ion in the water combined
with the carbonic acid in the water?
26
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATION
Product
Product
The Filtered Water Inonizer
The Filtered Water Ionizer
Model
CPE-06ALW/B
120 V~ 60 Hz
Standard power voltage
Extraction type
Separate filtrated/ion water extraction type, electronic extraction type
Cleaning indicator, check indicator, low water level indicator, cooling
indicator, ion water level display, Ion and cold Ion water display, ion/
filtrated water extraction display, cooling mode selection display, and
continuous extraction display
Display part contents
An ion and cold ion water generation function and a water filtration
function
Major functions
Filtered water
6 L
Water tank
Cold water
capacity
3 L
Total
9 L
Electrode type/quantity
Electrolysis
5 white gold-plated titanium electrodes
62 mm X 110 mm (0.5 t)
vessel
Electrode specification
Dimension
350 mm(W) X 510 mm(D) X 511mm(H)
Working Temperature
5
°C - 35 °C
Production rate (on the basis of the
amount of water of the internal water
tank)
151 L/d (25 °C, 138 kPa)
Working Pressure
Net Weight
138 kPa – 827 kPa
24 kg
27
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER FLOW DIAGRAM
CPE-06Al
Notes
•
An fine post-carbon filter may be installed instead of a inno-sense filter .
For the precise specifications of your product, refer to the data plate on the product.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Water Filtration System Performance data Sheet
brand: Wellion
model: CPE-06Al
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, and 53 for
the reduction of the substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42 and 53.
Max. Allowable
Concentration
(mg/L)
Minimum
Percent
Reduction (%)
Average Influent Average Effluent
Average Percent
Reduction (%)
Substance
(mg/L)
(mg/L)
Aesthetic Chlorine
INNOSENSE
≥ 50%
≥ 50%
2.07
1.96
0.56
0.53
54.53
55.0
72.8
72.8
FINE POST
CARBON
VOC*
INNOSENSE
FINE POST
CARBON
≥ 95% reduction
≥ 95% reduction
0.327
0.317
0.0052
0.005
96.20
96.2
98.4
98.5
While testing was performed under laboratory conditions, actual performance may vary.
General Operating information:
251 gallons (for VOC)
6,103 gallons (for Aesthetic Chlorine)
INNOSENSE FILTER
Rated Capacity
FINE POST-CARBON
FILTER
280 gallons (for VOC)
1,179 gallons (for Aesthetic Chlorine)
Min-Max operating pressure:
Min-Max feed water temperature:
20 ~ 120 psi (1.4 ~ 8.4 kgf/cm2)
41 ~ 95 ºF (5 ~ 35 ºC)
0.07 GPM (for VOC)
0.5 GPM (for Aesthetic Chlorine)
Rated Service Flow
Electrical Requirements:
120 Vac / 60Hz
•
•
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user
responsibility, and parts and service availability.
•
•
For parts and service availability, please contact your local dealer or Coway.
The product water should be tested every 6 months to ensure that the contaminants are being reduced
effectively. Please contact your local dealer or Coway to initiate this service.
The estimated replacement time of filter, which is a consumable part, is not an indication of quality guarantee
period, but it means the ideal time of filter replacement. Accordingly, the estimated time of filter replacement
may be shortened in case it is used in an area of poor water quality.
•
Model of Filter
WJSF11-PLUS
WJCF8-PRE
Type
Usable period (months)
COST US $
7.84
PLUS SEDIMENT FILTER
PRE-CARBON FILTER
NF MEMBRANE FILTER
6
12
12
7.40
WJMF11-NF
30.00
INNO SENSE FILTER
/ FINE POST-CARBON
FILTER
WJIF11-S
/WJFCF11-POST
18
9.40
3.60
WJCC-02
CERAMIC FILTER
12
29
Download from Www.Somanuals.com. All Manuals Search And Download.
* VOC Surrogate Claims
Drinking water regulatory
Influent challenge
Chemical reduction
percent
Maximum product water
concentration mg/L
Chemical
level1 (MCL/MAC) mg/L
concentration2 mg/L
alachlor
0.002
0.003
0.005
0.04
0.005
0.1
0.050
0.100
0.081
0.190
0.078
0.077
0.015
0.110
0.052
0.080
0.040
0.088
0.083
0.170
0.086
0.080
0.079
0.170
0.053
0.088
0.044
> 98
> 97
> 99
> 99
98
0.0013
0.0033
0.0013
0.0013
0.00184
0.0013
0.00023
0.00174
0.000023
0.0013
0.0013
0.00485
0.0013
atrazine
benzene
carbofuran
carbon tetrachloride
chlorobenzene
> 99
99
chloropicrin
-
2,4-D
0.07
0.0002
0.6
98
dibromochloropropane(DBCP)
o-dichlorobenzene
p-dichlorobenzene
1,2-dichloroethane
1,1-dichloroethylene
cis-1,2-dichloroethylene
trans-1,2-dichloroethylene
1,2-dichloropropane
cis-1,3-dichloropropylene
dinoseb
> 99
> 99
> 98
955
0.075
0.005
0.007
0.07
0.1
> 99
> 99
> 99
> 99
> 99
99
0.00053
0.0013
0.0013
0.005
-
0.0013
0.007
0.002
0.7
0.00024
0.000594
0.0013
endrin
99
ethylbenzene
> 99
> 99
ethylene dilbromide (EDB)
0.00005
0.000023
haloacetonitriles (HAN)
bromochloroacetonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetoritrile
-
-
-
-
0.022
0.024
0.0096
0.015
98
98
98
98
0.00053
0.00063
0.00023
0.00033
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
-
-
0.0072
0.0082
99
96
0.00013
0.00033
heptachlor (H-34,Heptox)
heptachlor epoxide
hexachlorobutadiene
hexachlorocyclopentadiene
lindane
0.0004
0.0002
-
0.08
0.01076
0.044
0.060
0.055
0.050
0.096
0.120
0.150
0.081
0.081
0.078
0.270
0.042
0.160
0.084
0.150
0.180
> 99
98
0.0004
0.00026
0.0013
0.0000023
0.000013
0.00013
0.0013
0.0043
0.00053
0.0013
> 98
> 99
> 99
> 99
> 99
> 97
> 99
> 99
> 99
> 99
99
0.05
0.0002
0.04
0.001
0.004
0.1
methoxychlor
pentachlorophenol
simazine
styrene
1,1,2,2-tetrachloroethane
tetrachloroethylene
toluene
-
0.005
1
0.0013
0.0013
2,4,5-TP (silvex)
0.05
-
0.00164
0.0013
0.00053
0.00464
0.00053
0.00103
tribromoacetic acid
1,2,4-trichlorobenzene
1,1,1-trichloroethane
1,1,2-trichloroethane
trichloroethylene
trihalomethanes (includes):
> 98
> 99
95
0.07
0.2
0.005
0.005
> 99
> 99
chloroform (surrogate chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.080
10
0.300
0.070
95
0.015
xylenes (total)
> 99
0.0013
1. These harmonized values were agreed upon by representatives of USEPA and Health Canada for the purpose of evaluating products to the requirements
of this Standard.
2. Influent challenge levels are average influent concentrations determined in surrogate qualification testing.
3. Maximum product water level was not observed but was set at the detection limit of the analysis.
4. maximum product water level is set at a value determined in surrogate qualification testing.
5. Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough point as determined in surrogate qualification
testing.
6. The surrogate test results for heptachlor epoxide demonstrated a 98% reduction. These data were used to calculate an upper occurrence concentration
which would produce a maximum product water level at the MCL.
Woongjin Coway.,Ltd.
658, Yugu-Ri, Yugu Eub, Gongju-Si, Choongchungnam-Do, Korea
Tel.: 82-41-850-7879 Fax.: 82-41-841-7816
30
Download from Www.Somanuals.com. All Manuals Search And Download.
State of California
Department of Public Health
Water Treatment device
Certificate Number
08-1929
Date Issued: June 20, 2008
Trademark/model designation
Replacement Element(s)
Woongjin Coway Co. LTD Wellion CPE-06AL
WJSF11-PLUS
WJCF8-PRE
WJMF11-NF
WJIF11-S
WJCC-02
Manufacturer: Woongjin Coway Co LTD
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health
and Safety Code for the following health related contaminants:
microbiological Contaminants and Turbidity
None
inorganic/Radiological Contaminants
None
Organic Contaminants
VOCs
Alachlor
Endrin
Simazine
Atrazine
Benzene
Carbofuran
Carbon Tetrachloride
Chlorobenzene
Chloropicrin
2,4-D
DBCP
o-Dichlorobenzene
p-Dichlorobenzene
1,2-Dichloroethane
1,1-Dichloroethylene
cis-1,2-Dichloroethylene
trans-1,2-Dichloroethylene
1,2-Dichloropropane
cis-1,3-Dichloropropylene
Dinoseb
Ethylbenzene
EDB
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethylene
Toluene
Haloacetonitriles (HAN)
Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloroacetonitrile
Haloketones (HK)
1,1-Dichloro-2-Propanone
1,1,1-Trichloro-2-Propanone
Heptachlor
Heptachlor Epoxide
Hexachlorobutadiene
Hexachlorocyclopentadiene
Lindane
2,4,5-TP (Silvex)
Tribromoacetic Acid
1,2,4-Trichlorobenzene
1,1,1-Trichloroethane
1,1,2-Trichloroethane
Trichloroethylene
Trihalomethanes (THMs)
Bromodichloromethane
Bromoform
Chloroform
Chlorodibromomethane
Xylenes
Methoxychlor
Pentachlorophenol
Rated Service Capacity: 251 gal
Rated Service Flow: 0.07 gpm
do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection before or
after the system.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
MEMO
32
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTy CARd OR WARRANTy lETTER
ONE yEAR limiTEd WARRANTy
WATER FiRTRATiON dEViCE CPE-06AlW/b (“PROdUCT”)
Model:
Serial Number:
Customer Name:
Date of Purchase:
(“OWNER”)
What This Warranty Covers:
Limitations and Exclusions:
Commencing with the date of purchase of the
Product and continuing for a period of one year,
if manufacturing defects in the Product cause the
Product to not operate properly for its intended
use, then subject to the exclusions, conditions, and
limitations contained herein, COWAY at its sole
option will repair or replace the Product.
TO THE EXTENT PERMITTED BY APPLICABLE LAW,
COWAY DISCLAIMS ANY OTHER WARRANTY
EXPRESS OR IMPLIED, THAN THAT PROVIDED
FOR HEREIN. THIS WARRANTY IS IN LIEU OF AND
EXCLUDES ALL OTHER WARRANTIES, GUARANTEES,
CONDITIONS AND REPRESENTATIONS, EXPRESS
OR IMPLIED, ORAL OR WRITTEN, STATUTORY OR
OTHERWISE, INCLUDING BUT NOT LIMITED TO
ANY IMPLIED CONDITIONS OR WARRANTIES AS
TO THE MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE OF THE COWAY PRODUCT.
SOME STATES DO NOT ALLOW LIMITATIONS ON
HOW LONG AN IMPLIED WARRANTY LASTS, SO
THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
COWAY DOES NOT AUTHORIZE ANY PERSON
INCLUDING ITS REPRESENTATIVES, TO MAKE ANY
REPRESENTATION OR TO OFFER ANY WARRANTY,
CONDITION OR GUARANTY IN RESPECT OF THE
PRODUCT OTHER THAN THIS WARRANTY. THIS
LIMITED WARRANTY SHALL BE THE OWNER’S
SOLE AND EXCLUSIVE REMEDY AGAINST
COWAY AND COWAY SHALL NOT BE LIABLE FOR
ANY CONSEQUENTIAL, EXEMPLARY, SPECIAL,
INCIDENTAL OR OTHER DAMAGES INCLUDING,
BUT NOT LIMITED TO, LOSS OF PROFITS, AND
LOSS OF USE. INCIDENTAL, CONSEQUENTIAL
AND EXEMPLARY DAMAGES SHALL NOT BE
RECOVERABLE EVEN IF THE REMEDIES OR THE
ACTIONS PROVIDED FOR IN THIS WARRANTY FAIL
OF THEIR ESSENTIAL PURPOSE. SOME STATES DO
NOT ALLOW THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO
THE ABOVE LIMITATION OR EXCLUSION MAY NOT
APPLY TO YOU. COWAY SHALL NOT BE LIABLE
FOR ANY DAMAGES WHICH ARE BASED UPON
NEGLIGENCE, BREACH OF WARRANTY, STRICT
LIABILITY OR ANY OTHER LEGAL THEORY OF
LIABILITY OTHER THAN THE EXCLUSIVE LIABILITY
SET FORTH IN THIS WARRANTY
Decisions as to the extent of repair or replacement
required will be made solely by COWAY.
The remedy under this Warranty is available only
for that portion of the Product exhibiting defects
at the time of the warranty claim. The replacement
Product as well as any remaining original Product
will be warranted only for the original one year
warranty period. This limited warranty applies
only to Product used for an application specified
by COWAY for the Product and applied in strict
accordance with COWAY published specifications
in effect at the time of application. IF PRODUCT IS
USED FOR OTHER THAN ITS INTENDED PURPOSE,
IT IS SOLD AS IS AND WITHOUT ANY EXPRESS
OR IMPLIED WARRANTIES, INCLUDING OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
What This Warranty Does Not Cover:
This Warranty warrants that the Product will be
free from manufacturing defects which affect the
ability of the Product to operate for its intended
use; it is not a warranty that the Product will never
require repairs or to undertake responsibilities,
liabilities or obligations other than those
specifically identified in the preceding section.
COWAY is not responsible or liable for personal
injury or property damage of any kind, even if
arising from a breach of this Warranty.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Limitations on Implied Warranties:
Waiver:
Any implied warranty of merchantability or
fitness for a particular purpose or use, shall be
limited to the duration of the foregoing express
written warranty.
COWAY’s failure at any time to enforce or rely
upon any of the terms or conditions stated
herein shall not be construed to be a waiver of
its rights hereunder.
Conditions of Warranty:
Obtaining Warranty Service and OWNER’S
Duties:
COWAY’s continuing liability under this
Warranty is conditioned upon the following :
a) The defect or damage is not caused
by or is the result of : abnormal use or
If the Product fails to operate for its
intended purpose, then notify Coway or its
Representative Agency within 48 hours or
within the next business day after discovery
of any defect in the Product. The OWNER must
give written notice to COWAY no later than
thirty (30) days after a defect is discovered or
should by reasonable diligence have been
discovered. Claims under this Warranty will
require proof of purchase by the OWNER.
conditions; improper storage, unauthorized
modifications or repair; misuse, neglect,
accident, alteration, improper installation or
other acts that are not the fault of Coway or
the manufacturer of the product or that are
not covered by the manufacturer’s warranty;
b) The Product has not been altered, modified
or repaired without prior written approval of
COWAY;
c) The OWNER has notified COWAY in writing
of any failure of the Product covered by this
Warranty within thirty (30) days following
such failure;
d) There has been no misuse, abuse or
negligence with respect to the Product on
the part of the OWNER.
USA
Add
: WOONGJIN COWAY USA, INC.
695 SOUTH VERMONT, STE. 110(SOUTH TOWER) LOS ANGELES, CA 90005, USA
Call center. : (213) 386-9900 / (213) 480-1600
Fax.
: (213) 386-3990
34
Download from Www.Somanuals.com. All Manuals Search And Download.
MADE IN KOREA
003
1005760
Download from Www.Somanuals.com. All Manuals Search And Download.
|