DEAR CUSTOMERS  
Thank you for using our Filtered Water Inonizer.  
Please read this Users’ Manual to use and maintain the product correctly. If you encounter a  
problem while using the product, you may solve the problem referring to the User’s Manual.  
As this manual contains the product warranty card, please keep it in a safe place.  
This system (CPE-06AL) conforms to NSF/ANSI 42 for aesthetic chlorine and NSF/ANSI 53 for VOC  
as verified and substantiated by test data.  
See performance data sheet for individual contaminants and reduction performance.  
CONTENTS  
FOR INFORMATION  
HOW TO USE  
SAFETy iNFORmATiON. . . . . . . . . . . . . . . . . . . 3  
Electricity safety . . . . . . . . . . . . . . . . . . . . . . . 3  
Installation safety. . . . . . . . . . . . . . . . . . . . . . 4  
Operation safety. . . . . . . . . . . . . . . . . . . . . . . 5  
Others. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
iNSTAllATiON PRECAUTiONS . . . . . . . . . . .10  
OPERATiON / iNdiCATiON PART . . . . . . . . .12  
HOW TO USE. . . . . . . . . . . . . . . . . . . . . . . . . . . .15  
To drink the cold ion water . . . . . . . . . . . . 15  
To drink the ion water. . . . . . . . . . . . . . . . . 15  
To drink the ambient water. . . . . . . . . . . . 15  
To extract continuosly . . . . . . . . . . . . . . . . 16  
PARTS NAmE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
WATER FilTRATiON PROCESS. . . . . . . . . . . . . 8  
MAINTENANCE  
OTHERS  
iNSTAllATiON . . . . . . . . . . . . . . . . . . . . . . . . . .17  
TROUblESHOOTiNG . . . . . . . . . . . . . . . . . . . .25  
SPECiFiCATiON . . . . . . . . . . . . . . . . . . . . . . . . .27  
WATER FlOW diAGRAm . . . . . . . . . . . . . . . . .28  
PERFORmANCE dATA SHEET . . . . . . . . . . . .29  
WARRANTy CARd. . . . . . . . . . . . . . . . . . . . . . .33  
ClEANiNG mETHOd . . . . . . . . . . . . . . . . . . . .19  
Storage tank. . . . . . . . . . . . . . . . . . . . . . . . . . 19  
Gutter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
FilTER REPlACEmENT. . . . . . . . . . . . . . . . . . .22  
FilTER REPlACEmENT mETHOd . . . . . . . . .23  
2
- Please keep the User’s manual where it can be readily reached or found -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETy INFORMATION  
Be careful to keep this safety information.  
Please read this information to prevent property loss and ensure your safety.  
If not observed,  
serious injury or  
even death could  
occur.  
If not observed,  
serious injury or  
property damage  
could occur.  
If not observed, slight  
injury or property  
damage could occur.  
Danger  
Warning  
Caution  
Electricity safety  
do not use a damaged  
power cord or plug, and  
loose outlet.  
Otherwise, electric shock or  
fire may occur as a result.  
do not pull the power  
cord.  
Otherwise, electric shock or  
fire may occur as a result.  
do not carry the unit by  
its power cord.  
do not touch the power  
plug with a wet hand.  
Otherwise, electric shock or  
fire may occur as a result.  
Otherwise, electric shock or  
fire may occur as a result.  
do not forcefully bend  
the power cord or put  
it under a heavy object  
to prevent it from being  
damaged or deformed.  
do not connect and  
pull out the power plug  
repeatedly.  
Otherwise, electric shock or  
fire may occur as a result.  
Otherwise, electric shock or  
fire may occur as a result.  
if the electric outlet is  
wet, carefully unplug the  
unit and let the electric  
outlet completely dry  
before subsequent use.  
Unplug the product  
before repair, inspection,  
or parts replacement.  
Otherwise, electric shock or  
fire may occur as a result.  
Otherwise, electric shock or  
fire may occur as a result.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remove any dust or  
water off in the pin and  
contacts of the power  
plug.  
do not plug into an  
outlet that is being  
used by several other  
appliances.  
Otherwise, electric shock or  
fire may occur as a result.  
Use an electrical outlet  
dedicated.  
Otherwise, fire may occur as  
a result.  
When you don’t use for a  
long time, close the main  
water supply valve and  
unplug.  
Otherwise, electric shock or  
fire may occur as a result.  
do not attempt to repair  
or modify the power cord  
at your discretion.  
Otherwise, electric shock or  
fire may occur as a result.  
in the case the power  
cord is damaged, do  
not replace the cord  
yourself. Call Coway  
Service Center to have it  
replaced.  
Otherwise, electric shock or  
fire may occur as a result.  
Installation safety  
do not install near a  
heating device.  
Otherwise, fire may occur as  
a result.  
do not install the  
product on a sloped  
floor.  
Injury to the user or damage  
to the unit may result.  
do not press the product  
by constraint or impact.  
Injury to damage to the unit  
may result.  
The filtration device installation shall  
comply with applicable state and local  
regulations.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETy INFORMATION  
If not observed,  
serious injury or  
even death could  
occur.  
If not observed,  
If not observed, slight  
injury or property  
damage could occur.  
serious injury or  
property damage  
could occur.  
Danger  
Warning  
Caution  
Operation safety  
When the water is  
coming inside of the  
product or there is a  
puddle on the product,  
call Service Center after  
closing the supplying  
valve and unplugging.  
if our product produces a  
strange noise or odd  
smell, immediately  
unplug from the  
electrical outlet and call  
our Service Center.  
Otherwise, electric shock or  
fire may occur as a result.  
Otherwise, electric shock may  
occur as a result.  
do not put the candle, a  
light for cigarette on the  
products.  
Otherwise, fire may occur as  
a result.  
do not place any  
containers with water,  
medicine, food, small  
metallic objects, or any  
flammable material on  
the top of the product.  
In the case foreign material  
gets inside the product,  
electric shock, fire, product  
damage may occur as a result.  
Use after closing the  
water tank cover  
completely inside of the  
product.  
To drink the filtered  
water, change the filter  
according to the filter  
replacement cycle.  
The buck or the foreign body  
can be entered.  
If you use the expired filter,  
the filter performance is  
lowered.  
When you don’t use for  
a long time, use after  
draining the saved  
water completely and  
emptying the newly  
ambient water once  
again.  
The saved water can be  
polluted.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danger Warning Caution  
Others  
Clean after unplugging.  
Otherwise, electric shock or  
fire may occur as a result.  
do not clean by spraying  
the water directly or  
don’t wipe the product  
using the benzene and  
thinner.  
Otherwise, electric shock or  
fire may occur as a result.  
do not repair,  
do not use filtered water  
for the water exchange  
of an aquarium or a  
fishbowl.  
The ambient water through  
the membrane isn’t suitable  
for the fish’s life environment  
as it removed the ionic  
disassemble, or modify.  
Otherwise, electric shock or  
product damage may occur  
as a result.  
material. In some cases, fishes  
might even die.  
After moving the product  
or replacing the inno-  
sense filter, the black  
powder can be remained  
in the inner bottom of  
the water tank.  
do not use with water  
that is microbiologically  
unsafe or of unknown  
quality without adequate  
disinfection before or  
after the ststem.  
It is quiet harmless as the  
powder of the activated  
carbon used in the inno-sense  
filter was flowed out for  
improving the water tastes .  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS NAME  
Front  
Operation Part  
Indication Part  
Continuous Extraction Button  
Ambient Water Extraction Lever  
Front Draining Door  
Ion Water Extraction Lever  
Rear  
Top Cover  
Wire Condenser  
Power Cord  
Inlet(Orange) Tubing  
Outlet(Blue) Tubing  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER FILTRATION PROCESS  
The filter is the core technology of the filtration system.  
If you don’t use qualifying filter or if you use an old filter that has expired, the system  
performance may degrade.  
The 5-step Water Filtering System(CPE-06AL)  
Step 1 : PlUS SEdimENT FilTER  
This plus sediment filter has the functions to reduce infusible particles from feed water and to  
protect membrane and pre-carbon filter from being plugged.  
Step 2 : PRE-CARbON FilTER  
This pre-carbon filter has the function to reduce aesthetic chlorine, odor, volatile organic  
compounds(VOC’s).  
Step 3 : NF mEmbRANE FilTER  
Step 4 : iNNO-SENSE FilTER  
This inno-sense filter has the functions to reduce smell induction material and to improve taste of  
water. It also has the function to reduce aesthetic chlorine, volatile organic compounds(VOC’s).  
Step 5 : CERAmiC FilTER  
PLUS SEDIMENT  
FILTER  
PRE-CARBON  
FILTER  
NF MEMBRANE  
FILTER  
INNO-SENSE  
FILTER  
CERAMIC  
FILTER  
CERAMIC  
FILTER  
Disposed  
Water  
Outlet  
Uses of disposed water  
-
The daily life water should be used for cleaning the restroom, the house, clothes, or  
purposes other than drinking.  
Tips  
-
Never use the daily life water for a drinking water or a cook.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER FILTRATION PROCESS  
The filter is the core technology of the filtration system.  
If you don’t use qualifying filter or if you use an old filter that has expired, the system  
performance may degrade.  
The 6-step Water Filtering System(CPE-06AL)  
Step 1 : PlUS SEdimENT FilTER  
This plus sediment filter has the functions to reduce infusible particles from feed water and to  
protect membrane and pre-carbon filter from being plugged.  
Step 2 : PRE-CARbON FilTER  
This pre-carbon filter has the function to reduce aesthetic chlorine, odor, volatile organic  
compounds(VOC’s).  
Step 3 : NF mEmbRANE FilTER  
Step 4, 5 : FiNE POST-CARbON FilTER  
This fine post-carbon filter has the functions to reduce smell induction material and to improve taste  
of water. It also has the function to reduce aesthetic chlorine, volatile organic compounds(VOC’s).  
Step 6 : CERAmiC FilTER  
PLUS SEDIMENT  
FILTER  
PRE-CARBON  
FILTER  
NF MEMBRANE FINE POST-CARBON CERAMIC  
FILTER FILTER FILTER  
CERAMIC  
FILTER  
Disposed  
Water  
Outlet  
Uses of disposed water  
-
The daily life water should be used for cleaning the restroom, the house, clothes, or  
purposes other than drinking.  
Tips  
-
Never use the daily life water for a drinking water or a cook.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION PRECAUTIONS  
The summary for the proper installation of the water filtration device  
1. Close main water supply valve to separate the faucet.  
2. Wind the teflon tape on the adaptor and fit it to the  
pipe.  
do not turn the water pipe.  
3. Connect the faucet with the adaptor.  
Shall install the adaptor with connector on the cold water  
pipe.  
4. Connect 1/4 inch orange tubing with the connector  
on the adaptor.  
Flush water through each filter at least 5 minutes before  
Connection.  
5. Open the feed valve to supply water to the filtration  
system.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION PRECAUTIONS  
Please check before use!  
This product is for 120 V~ 60 Hz only.  
Please connect the power plug to a dedicated grounded electrical  
outlet for 120 V~ 60 Hz. The water filtration device works normally  
only when the electricity is connected.  
• Open the main water supply valve.  
• The main water must be supplied to operate the water filtration device normally.  
• After installing the product  
Get rid of the saved water above the full water in the inner water tank 2 times or more to use.  
• When the indicator in the indication part is turned off  
When the indicator in the indication part is turned off, check if the power supply was stopped  
due to the power failure or other cause.  
• Regularly filter replacement  
It is important to replace the filter regularly to drink the pure water. If the filter is overused  
beyond its service life, the performance of the water filtration device deteriorate, Do not miss the  
filter replacement cycle.  
• When you didn’t use for a long time  
If you saved the water for a long time or you didn’t use, drain the water inside of the water  
filtration device completely and remove the newly filtered water one time to use.  
• When you don’t want to use for a long time  
Close the main water supply valve and unplug.  
When you don’t use for a long time, close the main water supply valve and unplug.  
Tips  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION / INDICATION PART  
Indication part/Operation part  
Indication Part  
Operation Part  
Cooling mode  
selection button  
Ion water  
button  
Strong alkaline  
water button  
1
2
3
Weak alkaline  
water button  
Power  
indicator  
Cooling  
indicator  
Cleaning  
indicator  
4
1
2
4
Cold ion  
water button  
Continuous  
extraction button  
Low level  
indicator  
Check  
indicator  
5
6
3
5
1
2
4
Power indicator  
Cooling indicator  
If you connect the power,  
the indicator is turned on.  
The indicator blinks during  
the continuous extraction.  
When selecting cooling mode,  
the indicator is turned on.  
When cooling is complete, the  
indicator is turned off.  
3
5
low level indicator  
If the water level of the  
internal water tank is low,  
the indicator is turned on.  
Cleaning indicator  
While cleaning the electrolysis  
vessel, the indicator is turned  
on.  
Check indicator  
If a problem occurs with the  
product, the indicator is turned  
on. In this case, please contact  
our after-service center.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION / INDICATION PART  
Operation part  
1
2
Cooling mode  
ion water button  
selection button  
Press this button to extract  
ionized water. If you press  
this button, the button is  
turned on.  
Press this button to select or  
deselect cooling mode. This  
button is turned on when  
cooling mode is selected.  
3
4
Strong alkaline water  
button  
Weak alkaline water  
button  
Press this button to extract  
strong alkaline water. If you  
press this button, the button  
is turned on.  
Press this button to extract  
weak alkaline water. If you  
press this button, the button  
is turned on.  
5
6
Cold ion water button  
Continuous  
Continuous  
Extraction  
extraction button  
Press this button to extract  
water continuously.  
Press this button to extract  
cold ionized water. If you press  
this button, the button is  
turned on.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To use the cold water function  
Press the cold mode button and confirm that the cold  
mode button is turned on. If you want to turn off cold  
mode, press and hold the button for about 3 seconds or  
more.  
You can drink cold ion water in about two hours after  
turning the cold mode.  
If no key is pressed for 1 minute after ionized  
water has been extracted.  
Electrolysis vessel cleaning function  
The auto electrolysis vessel cleaning function is provided  
to keep the vessel clean and protect the product. During  
electrolysis vessel cleaning, the cleaning indicator is  
turned on.  
De  
vice  
tion  
F
iltra  
er  
Wat  
or  
requ  
nerat  
ce Ge  
do  
bstan  
cal Su  
Medi  
ired.  
i
s
a
ctor  
n
wit  
h
C
onsultatio  
1 If no ionized water is extracted 1 minute after ionized  
water is extracted, the vessel is cleaned automatically.  
2 If the stop period exceeds 7 hours after water is  
extracted, the vessel is cleaned automatically.  
3 If about 30 minutes has passed after the power is  
turned on and then cool mode is turned on, the vessel  
If the stop period exceeds 7 hours after water  
has been extracted.  
is cleaned automatically  
.
De  
vice  
tion  
F
iltra  
er  
Wat  
or  
is req  
nerat  
octor  
ce Ge  
d
bstan  
cal Su  
Medi  
Cons  
.
uired  
a
on  
ultati  
w
ith  
If about 30 minutes has passed after cool mode  
has been turned on.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO USE  
To drink cold ion water  
Push high or low alkaline button. Then push cold ion water button. You can have cold ion water by  
push extraction lever of cold ion water.  
Devi  
ce  
ation  
r
Filtr  
Wate  
c
e
G
e
n
erator  
ctor is re  
n
l
Substa  
w
Medica  
Consult  
quired  
.
ith  
a
do  
ation  
Safety interruption feature: extraction stops automatically after 1 minute continuous  
extraction.  
If low level lamp is on, cold lon water is not extracted.  
Tips  
Ion water and cold ion water button is canceled automatically 10 seconds after  
extraction.  
According to environment or user’s drinking habit, the first cup maybe not cold enough.  
but it is not product break down. However, you can have cold water from second cup.  
To drink ion water  
Choose high or low alkaline button. Then push ion water button. You can have ion water by push  
extraction lever of ion water.  
vice  
ion De  
Filtrat  
Water  
e
G
e
n
e
r
ator  
c
Substan  
Medical  
r
e
q
u
i
r
e
d.  
i
s
o
n
w
i
t
h
a
doctor  
t
i
C
onsulta  
Safety interruption feature: extraction stops automatically after 1 minute continuous  
extraction.  
If low level lamp is on, cold lon water is not extracted.  
Tips  
Ion water and cold ion water button is canceled automatically 10 seconds after  
extraction.  
To drink ambient water  
You can have ambient water by push ambient water lever.  
vice  
on De  
W
a ter  
Filtrati  
r
Generato  
Medical  
S
ubstance  
ion with  
o
c
t
o
r
i
s
required  
.
a
d
C
onsultat  
Safety interruption feature : if pushing the lever for 2  
minutes continuously, extraction stops automatically.  
Tips  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To extract continuosly  
To extract ionized water continuously  
To extract filtrated water continuously  
Lamp status  
To extract ionized water continuously, press the strong or weak  
alkaline button. Press the Ion water or cold mode button.(Make  
sure to confirm that the required ion water selection button  
is turned on.) If you press and hold the continuous extraction  
button for about 2 seconds, you can receive the selected ion  
water for about 1 minute.  
When extracting water continuously, check if the ion water  
and cold mode buttons are turned off. (If you press a button  
that has been turned on again, the button is turned off.)  
If you press and hold the continuous extraction button for  
about 2 seconds, you can receive water for about 2 minutes  
and 30 seconds.  
One more push on continuous extraction button  
stops continuous extraction.  
Ion water and cold ion water button is  
Tips  
automatically canceled after 10 seconds.  
- When the low water level indicator is turned on,  
the ion or cold ion water is not extracted.  
Continuous  
extraction  
Continuous  
extraction botton  
Button status  
on  
Cold ion water  
Medical Substance Generator  
Consultation with  
a
doctor is required.  
Water Filtration Device  
on  
Ion water  
Medical Substance Generator  
Consultation with  
a
doctor is required.  
Water Filtration Device  
Push and hold for 2  
seconds  
DECO Lamp  
flickering  
on  
Ambient water  
Medical Substance Generator  
Consultation with  
a
doctor is required.  
Water Filtration Device  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Follow the instruction for installation  
Main water  
supply valve  
Cooling stopper  
120 V~ 60 Hz Only  
1
Connect the orange color inlet tubing to the tap water  
2
supplying pipe. Connecting the outlet tubing  
.
Inlet tubing (Orange)  
Outlet tubing(Blue)  
1
2
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Be cautious!  
Water filtration device installation place 1  
Please install the water filtration system not at a rough place, a damp  
place, a place where the unit is exposed to the direct sunlight, a  
place where dust is present, or a place that the water drops.  
Water filtration device installation place 2  
Please install at the place where it is 10 cm or more off from the wall  
and the bottom is flat and firm.  
After installing the water filtration system  
Filtered water: Fill the water tank with the filtrated water and remove  
the water twice or more if necessary after installing it.  
Ion water: Fill the water tank with the ionized water and remove the  
water twice or more if necessary after installing it.  
Removing moisture: Remove moisture and dust from the operating,  
display and connecting parts of the front cover.  
Cold water plumbing  
Cold water  
plumbing  
Please connect to the cold water pipe necessarily. (If you connect to  
the warm water pipe, the filter can be damaged.)  
movement and installation  
When the position is moved, connect the power cord when 30  
minutes passes after installing.  
To maintain optimal product performance, consult a Coway engineer for the detailed  
installation methods.  
There may be some water remaining inside of the filter which was used to test the  
product during inspection process at the factory.  
Please feel at easy and use as it isn’t the used product.  
Don’t reuse the main water supply valve and hose that was previously  
used when you install the product.  
Tips  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING METHOD  
Storage tank  
1. Turn it off by pressing the cold mode button  
at the front panel of the product for about 3  
seconds and unplug the power cord. Close the  
main water supply valve.  
Take care that water does not enter the product  
other than through the water hose.  
Tips  
2. Please drain and store the water inside of the  
water filtration device completely using the  
draining hose.  
Please drain and store the water inside of the  
water filtration device completely using the  
draining hose.  
Tips  
3. Slide the top cover of the product backwards, open the fixing latches of the  
internal water tank, and then open the cover.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Separate the ceramic filter from the bottom of the cover of the internal  
water tank and use the stored water to clean it.  
5. Please wipe the surface of the storage tank  
with a soft cloth.  
6. drain the water completely  
using the draining hose after  
washing out the internal water  
tank with the stored water.  
You can drain the water within the internal water tank  
completely by lowering the draining part cover at the  
front and connecting the draining hose (the continuous  
Tips  
extraction hose).  
7. After installing the ceramic filter at the bottom of the cover of the internal  
water tank, close the internal water tank cover. lock the fixing latches of  
the internal water tank and close the cover.  
2
1
Because locking the fixing latch of the internal water tank incorrectly may cause the  
alien substances or bacteria to enter, please make sure that the fixing latches are  
locked correctly.  
Tips  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING METHOD  
8. Close the top cover, plug in the power cord and  
open the water supply valve.  
Close the storage tank cover completely.  
A worm or a foreign body can be entered.  
When you clean the storage tank, don’t use the medicine or the  
detergent.  
If you don’t clean the medicine or the detergent cleanly, it can be  
harmful to the body.  
Tips  
-
Keep the surroundings cleanly and clean the storage tank once  
per two months.  
Gutter  
1. Gutter separation method  
The gutter can be separated easily with lifting up the front  
part of the gutter and taking out.  
2. Gutter assembling methods  
Clean the gutter and then insert it into the groove at the  
bottom of the front of the product slightly to install it..  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FILTER REPLACEMENT  
Filter  
The life of the water filtration system is the filter. It it isn’t the legitimated  
filter or you use too long even if it is the legitimated filter, the filter  
performance can be lowered.  
Please change to the legitimated filter according to the replacement cycle.  
Filter replacement cycle  
If the filter is not regularly replaced, it may degrade the water quality from the product. The filter  
replacement cycle depending on the main water quality can be shortened  
rater than the expected replacement cycle.  
The period for the filter exchange is made based on 10 L use in a day for  
house use(4 people based) and 20 L use for business.  
CPE-06Al  
Part No.  
WJSF11-PLUS  
WJCF8-PRE  
WJMF11-NF  
Names of Filter  
Plus sediment fiter  
Pre-carbon filter  
Usable Period  
6 months  
12 months  
12 months  
NF membrane filter  
WJIF11-S  
/WJFCF11-POST  
Inno-sense filter  
/ Fine post-carbon filter  
18 months  
12 months  
WJCC-02  
Ceramic filter  
About filter replacement cycle  
The filter replacement cycle described above is not the filter quality  
warranty period but the expected cycle (life) that the filter shows its  
original performance.  
Therefore, the filter replacement cycle may be reduced for the area with  
the poor water quality or more application.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FILTER REPLACEMENT METHOD  
1. Close the main water supply valve after unplugging the power cord and  
drain the water inside of the internal water tank of the water filtration  
device (see p19).  
2. Open the top cover and loosen the fixing screw at the top of the product.  
Open the front cover and disconnect the connected cable completely.  
- Open the top cover by sliding it backwards.  
- Hold and pull the front cover in the direction of 1. Pull the front cover in the  
Tips  
direction of 3 while sliding the front cover in the direction of 2 to unlock the  
latch in the center on the left. Unlock the latch on the right according to the same  
method. Then the front cover is separated completely.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. After separating the fitting connected to the filter to replace, please  
replace the filter.(Separate the fitting using the proper tool.)  
By changing the filter and connecting the fitting and the hose precisely,  
check that there is no leakage and drain the first filtered water necessarily.  
Tips  
4. Connect all the cables and close the front cover making sure to align the  
groove. Fasten the fixing screw of the top of the product with a screw  
driver and close the top cover.  
1
2
3
Please be sure to use a new filter after cleansing.  
-
-
Plus sediment filter: Install after cleaning with the main water for about 3 minutes.  
Pre-carbon/Fine post carbon/Inno-sense filter: Please assemble it after cleansing  
Tips  
it with the water passed through  
the plus sediment filter for about 3  
minutes.  
-
Membrane filter: Please assemble it after cleansing it with the water passed  
through the plus-sediment filter and the pre-carbon filter for  
about 3 minutes.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
The water filtration device may operate abnormally due to minor causes not because of the  
product malfunction but because of the fact that the user is not familiar with the product use.  
In such a case, problems can be solved easily even without the help from the Service Center by  
checking the following items. If you can’t solve the problem after checking the following items,  
please call the Service Center.  
Symptom  
Check  
Measures to take  
• Did you clean the internal water tank?  
Clean the internal water tank.  
Get rid of the saved water and clean the  
internal water tank.  
The water tastes odd.  
•You didn’t use it for a long time.  
Use ionized water only after extracting and  
disposing of the water more than twice in  
ionized water mode.  
•Is it time to change the filter?  
•The water is flowing slower.  
Request a filter replacement.  
Request a filter replacement.  
Check if the power cord is plugged into a  
120 V~ 60 Hz outlet.  
•Is the power connected?  
The water is flowing  
slower.  
•Did you close the main water supply valve?  
Open the main water supply valve.  
•Did the temperature of the main water drop  
suddenly?  
The amount of filtrated water decreases as  
the temperature of the water drops.  
Press the Cold Mode button so that it is  
turned on.  
•Is the Cold Mode button turned on?  
•Is the Cooling indicator turned on?  
There is no cold  
water.  
Cold Mode is in progress. Please use it in  
1~2 hours.  
•Is the back of the product too close to the  
wall?  
Keep the product away from the wall by at  
least 10 cm.  
• It may be time to change the filter.  
Request a filter replacement.  
• Is the water supply cut or is the water supply  
valve closed?  
Open the main water supply valve.  
Water is not  
In this case, please contact the After-  
Service Center.  
extracted or the  
amount of water is  
not correct.  
•The level is incorrect.  
• Is the draining or feed hose bent or folded?  
• Is the feed hose too long?  
Unfold the hose.  
Keep the length of the feed hose equal to  
or shorter than 5 m.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Symptom  
Check  
Measures to take  
• Do you live in an area where the water  
hardness is high?  
The pH is subject to the region and the  
quality of water.  
Keep the height of the domestic water  
outlet hose equal to or lower than 25 cm  
from the bottom of the product.  
The pH level is  
incorrect.  
• Is the height of the domestic water outlet  
hose too high?  
In this case, please contact the After-  
Service Center.  
• Is the amount of draining water small?  
• Is the water being supplied actively?  
• Is the power connected?  
Check the water supply valve.  
Check if the power cord is plugged into a  
120V~ 60Hz outlet.  
All operations were  
stopped suddenly  
while operating.  
In this case, please contact the After-  
Service Center.  
• Is water overflowing or leaking?  
• In this case, please contact the After-  
Service Center.  
The amount of filtrated water decreases as  
the temperature of the water drops.  
• Did the water flow out of the internal  
water tank cover or from the inside of the  
product?  
Open the top cover to check where the  
water is leaking, close the water supply  
valve and contact the After-Service Center.  
Water leaks.  
Close the water supply valve and contact  
the After-Service Center. The ionized water  
extraction stops automatically.  
• Water leaks when extracting ionized water.  
• Ionized water extraction automatically  
stops after 1 minute to prevent overflowing  
by mistake.  
There is insufficient water in the internal  
water tank. In this case, use the water  
within 1~2 hours.  
Did the extraction time  
exceed 1 minute?  
Is the Low level indicator turned on?  
There is insufficient water in the internal  
water tank. In this case, use the water  
within 1~2 hours.  
• A white substance settles at the bottom  
when ionized water is left over.  
This is because of the separation of the  
calcium mineral in the water depending on  
the quality of the water. Although drinking  
the water is safe, if this symptom continues,  
ask your After-Sales Center how to protect  
the product.  
A white substance  
settles at the bottom  
when ionized water  
is left over.  
• Has the calcium ion in the water combined  
with the carbonic acid in the water?  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATION  
Product  
Product  
The Filtered Water Inonizer  
The Filtered Water Ionizer  
Model  
CPE-06ALW/B  
120 V~ 60 Hz  
Standard power voltage  
Extraction type  
Separate filtrated/ion water extraction type, electronic extraction type  
Cleaning indicator, check indicator, low water level indicator, cooling  
indicator, ion water level display, Ion and cold Ion water display, ion/  
filtrated water extraction display, cooling mode selection display, and  
continuous extraction display  
Display part contents  
An ion and cold ion water generation function and a water filtration  
function  
Major functions  
Filtered water  
6 L  
Water tank  
Cold water  
capacity  
3 L  
Total  
9 L  
Electrode type/quantity  
Electrolysis  
5 white gold-plated titanium electrodes  
62 mm X 110 mm (0.5 t)  
vessel  
Electrode specification  
Dimension  
350 mm(W) X 510 mm(D) X 511mm(H)  
Working Temperature  
5
°C - 35 °C  
Production rate (on the basis of the  
amount of water of the internal water  
tank)  
151 L/d (25 °C, 138 kPa)  
Working Pressure  
Net Weight  
138 kPa – 827 kPa  
24 kg  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER FLOW DIAGRAM  
CPE-06Al  
Notes  
An fine post-carbon filter may be installed instead of a inno-sense filter .  
For the precise specifications of your product, refer to the data plate on the product.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Water Filtration System Performance data Sheet  
brand: Wellion  
model: CPE-06Al  
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, and 53 for  
the reduction of the substances listed below. The concentration of the indicated substances in water entering the  
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as  
specified in NSF/ANSI 42 and 53.  
Max. Allowable  
Concentration  
(mg/L)  
Minimum  
Percent  
Reduction (%)  
Average Influent Average Effluent  
Average Percent  
Reduction (%)  
Substance  
(mg/L)  
(mg/L)  
Aesthetic Chlorine  
INNOSENSE  
≥ 50%  
≥ 50%  
2.07  
1.96  
0.56  
0.53  
54.53  
55.0  
72.8  
72.8  
FINE POST  
CARBON  
VOC*  
INNOSENSE  
FINE POST  
CARBON  
≥ 95% reduction  
≥ 95% reduction  
0.327  
0.317  
0.0052  
0.005  
96.20  
96.2  
98.4  
98.5  
While testing was performed under laboratory conditions, actual performance may vary.  
General Operating information:  
251 gallons (for VOC)  
6,103 gallons (for Aesthetic Chlorine)  
INNOSENSE FILTER  
Rated Capacity  
FINE POST-CARBON  
FILTER  
280 gallons (for VOC)  
1,179 gallons (for Aesthetic Chlorine)  
Min-Max operating pressure:  
Min-Max feed water temperature:  
20 ~ 120 psi (1.4 ~ 8.4 kgf/cm2)  
41 ~ 95 ºF (5 ~ 35 ºC)  
0.07 GPM (for VOC)  
0.5 GPM (for Aesthetic Chlorine)  
Rated Service Flow  
Electrical Requirements:  
120 Vac / 60Hz  
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection  
before or after the system.  
Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user  
responsibility, and parts and service availability.  
For parts and service availability, please contact your local dealer or Coway.  
The product water should be tested every 6 months to ensure that the contaminants are being reduced  
effectively. Please contact your local dealer or Coway to initiate this service.  
The estimated replacement time of filter, which is a consumable part, is not an indication of quality guarantee  
period, but it means the ideal time of filter replacement. Accordingly, the estimated time of filter replacement  
may be shortened in case it is used in an area of poor water quality.  
Model of Filter  
WJSF11-PLUS  
WJCF8-PRE  
Type  
Usable period (months)  
COST US $  
7.84  
PLUS SEDIMENT FILTER  
PRE-CARBON FILTER  
NF MEMBRANE FILTER  
6
12  
12  
7.40  
WJMF11-NF  
30.00  
INNO SENSE FILTER  
/ FINE POST-CARBON  
FILTER  
WJIF11-S  
/WJFCF11-POST  
18  
9.40  
3.60  
WJCC-02  
CERAMIC FILTER  
12  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
* VOC Surrogate Claims  
Drinking water regulatory  
Influent challenge  
Chemical reduction  
percent  
Maximum product water  
concentration mg/L  
Chemical  
level1 (MCL/MAC) mg/L  
concentration2 mg/L  
alachlor  
0.002  
0.003  
0.005  
0.04  
0.005  
0.1  
0.050  
0.100  
0.081  
0.190  
0.078  
0.077  
0.015  
0.110  
0.052  
0.080  
0.040  
0.088  
0.083  
0.170  
0.086  
0.080  
0.079  
0.170  
0.053  
0.088  
0.044  
> 98  
> 97  
> 99  
> 99  
98  
0.0013  
0.0033  
0.0013  
0.0013  
0.00184  
0.0013  
0.00023  
0.00174  
0.000023  
0.0013  
0.0013  
0.00485  
0.0013  
atrazine  
benzene  
carbofuran  
carbon tetrachloride  
chlorobenzene  
> 99  
99  
chloropicrin  
-
2,4-D  
0.07  
0.0002  
0.6  
98  
dibromochloropropane(DBCP)  
o-dichlorobenzene  
p-dichlorobenzene  
1,2-dichloroethane  
1,1-dichloroethylene  
cis-1,2-dichloroethylene  
trans-1,2-dichloroethylene  
1,2-dichloropropane  
cis-1,3-dichloropropylene  
dinoseb  
> 99  
> 99  
> 98  
955  
0.075  
0.005  
0.007  
0.07  
0.1  
> 99  
> 99  
> 99  
> 99  
> 99  
99  
0.00053  
0.0013  
0.0013  
0.005  
-
0.0013  
0.007  
0.002  
0.7  
0.00024  
0.000594  
0.0013  
endrin  
99  
ethylbenzene  
> 99  
> 99  
ethylene dilbromide (EDB)  
0.00005  
0.000023  
haloacetonitriles (HAN)  
bromochloroacetonitrile  
dibromoacetonitrile  
dichloroacetonitrile  
trichloroacetoritrile  
-
-
-
-
0.022  
0.024  
0.0096  
0.015  
98  
98  
98  
98  
0.00053  
0.00063  
0.00023  
0.00033  
haloketones (HK):  
1,1-dichloro-2-propanone  
1,1,1-trichloro-2-propanone  
-
-
0.0072  
0.0082  
99  
96  
0.00013  
0.00033  
heptachlor (H-34,Heptox)  
heptachlor epoxide  
hexachlorobutadiene  
hexachlorocyclopentadiene  
lindane  
0.0004  
0.0002  
-
0.08  
0.01076  
0.044  
0.060  
0.055  
0.050  
0.096  
0.120  
0.150  
0.081  
0.081  
0.078  
0.270  
0.042  
0.160  
0.084  
0.150  
0.180  
> 99  
98  
0.0004  
0.00026  
0.0013  
0.0000023  
0.000013  
0.00013  
0.0013  
0.0043  
0.00053  
0.0013  
> 98  
> 99  
> 99  
> 99  
> 99  
> 97  
> 99  
> 99  
> 99  
> 99  
99  
0.05  
0.0002  
0.04  
0.001  
0.004  
0.1  
methoxychlor  
pentachlorophenol  
simazine  
styrene  
1,1,2,2-tetrachloroethane  
tetrachloroethylene  
toluene  
-
0.005  
1
0.0013  
0.0013  
2,4,5-TP (silvex)  
0.05  
-
0.00164  
0.0013  
0.00053  
0.00464  
0.00053  
0.00103  
tribromoacetic acid  
1,2,4-trichlorobenzene  
1,1,1-trichloroethane  
1,1,2-trichloroethane  
trichloroethylene  
trihalomethanes (includes):  
> 98  
> 99  
95  
0.07  
0.2  
0.005  
0.005  
> 99  
> 99  
chloroform (surrogate chemical)  
bromoform  
bromodichloromethane  
chlorodibromomethane  
0.080  
10  
0.300  
0.070  
95  
0.015  
xylenes (total)  
> 99  
0.0013  
1. These harmonized values were agreed upon by representatives of USEPA and Health Canada for the purpose of evaluating products to the requirements  
of this Standard.  
2. Influent challenge levels are average influent concentrations determined in surrogate qualification testing.  
3. Maximum product water level was not observed but was set at the detection limit of the analysis.  
4. maximum product water level is set at a value determined in surrogate qualification testing.  
5. Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough point as determined in surrogate qualification  
testing.  
6. The surrogate test results for heptachlor epoxide demonstrated a 98% reduction. These data were used to calculate an upper occurrence concentration  
which would produce a maximum product water level at the MCL.  
Woongjin Coway.,Ltd.  
658, Yugu-Ri, Yugu Eub, Gongju-Si, Choongchungnam-Do, Korea  
Tel.: 82-41-850-7879 Fax.: 82-41-841-7816  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
State of California  
Department of Public Health  
Water Treatment device  
Certificate Number  
08-1929  
Date Issued: June 20, 2008  
Trademark/model designation  
Replacement Element(s)  
Woongjin Coway Co. LTD Wellion CPE-06AL  
WJSF11-PLUS  
WJCF8-PRE  
WJMF11-NF  
WJIF11-S  
WJCC-02  
Manufacturer: Woongjin Coway Co LTD  
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health  
and Safety Code for the following health related contaminants:  
microbiological Contaminants and Turbidity  
None  
inorganic/Radiological Contaminants  
None  
Organic Contaminants  
VOCs  
Alachlor  
Endrin  
Simazine  
Atrazine  
Benzene  
Carbofuran  
Carbon Tetrachloride  
Chlorobenzene  
Chloropicrin  
2,4-D  
DBCP  
o-Dichlorobenzene  
p-Dichlorobenzene  
1,2-Dichloroethane  
1,1-Dichloroethylene  
cis-1,2-Dichloroethylene  
trans-1,2-Dichloroethylene  
1,2-Dichloropropane  
cis-1,3-Dichloropropylene  
Dinoseb  
Ethylbenzene  
EDB  
Styrene  
1,1,2,2-Tetrachloroethane  
Tetrachloroethylene  
Toluene  
Haloacetonitriles (HAN)  
Bromochloroacetonitrile  
Dibromoacetonitrile  
Dichloroacetonitrile  
Trichloroacetonitrile  
Haloketones (HK)  
1,1-Dichloro-2-Propanone  
1,1,1-Trichloro-2-Propanone  
Heptachlor  
Heptachlor Epoxide  
Hexachlorobutadiene  
Hexachlorocyclopentadiene  
Lindane  
2,4,5-TP (Silvex)  
Tribromoacetic Acid  
1,2,4-Trichlorobenzene  
1,1,1-Trichloroethane  
1,1,2-Trichloroethane  
Trichloroethylene  
Trihalomethanes (THMs)  
Bromodichloromethane  
Bromoform  
Chloroform  
Chlorodibromomethane  
Xylenes  
Methoxychlor  
Pentachlorophenol  
Rated Service Capacity: 251 gal  
Rated Service Flow: 0.07 gpm  
do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection before or  
after the system.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MEMO  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTy CARd OR WARRANTy lETTER  
ONE yEAR limiTEd WARRANTy  
WATER FiRTRATiON dEViCE CPE-06AlW/b (“PROdUCT”)  
Model:  
Serial Number:  
Customer Name:  
Date of Purchase:  
(“OWNER”)  
What This Warranty Covers:  
Limitations and Exclusions:  
Commencing with the date of purchase of the  
Product and continuing for a period of one year,  
if manufacturing defects in the Product cause the  
Product to not operate properly for its intended  
use, then subject to the exclusions, conditions, and  
limitations contained herein, COWAY at its sole  
option will repair or replace the Product.  
TO THE EXTENT PERMITTED BY APPLICABLE LAW,  
COWAY DISCLAIMS ANY OTHER WARRANTY  
EXPRESS OR IMPLIED, THAN THAT PROVIDED  
FOR HEREIN. THIS WARRANTY IS IN LIEU OF AND  
EXCLUDES ALL OTHER WARRANTIES, GUARANTEES,  
CONDITIONS AND REPRESENTATIONS, EXPRESS  
OR IMPLIED, ORAL OR WRITTEN, STATUTORY OR  
OTHERWISE, INCLUDING BUT NOT LIMITED TO  
ANY IMPLIED CONDITIONS OR WARRANTIES AS  
TO THE MERCHANTABILITY OR FITNESS FOR A  
PARTICULAR PURPOSE OF THE COWAY PRODUCT.  
SOME STATES DO NOT ALLOW LIMITATIONS ON  
HOW LONG AN IMPLIED WARRANTY LASTS, SO  
THE ABOVE LIMITATION MAY NOT APPLY TO YOU.  
COWAY DOES NOT AUTHORIZE ANY PERSON  
INCLUDING ITS REPRESENTATIVES, TO MAKE ANY  
REPRESENTATION OR TO OFFER ANY WARRANTY,  
CONDITION OR GUARANTY IN RESPECT OF THE  
PRODUCT OTHER THAN THIS WARRANTY. THIS  
LIMITED WARRANTY SHALL BE THE OWNER’S  
SOLE AND EXCLUSIVE REMEDY AGAINST  
COWAY AND COWAY SHALL NOT BE LIABLE FOR  
ANY CONSEQUENTIAL, EXEMPLARY, SPECIAL,  
INCIDENTAL OR OTHER DAMAGES INCLUDING,  
BUT NOT LIMITED TO, LOSS OF PROFITS, AND  
LOSS OF USE. INCIDENTAL, CONSEQUENTIAL  
AND EXEMPLARY DAMAGES SHALL NOT BE  
RECOVERABLE EVEN IF THE REMEDIES OR THE  
ACTIONS PROVIDED FOR IN THIS WARRANTY FAIL  
OF THEIR ESSENTIAL PURPOSE. SOME STATES DO  
NOT ALLOW THE EXCLUSION OR LIMITATION OF  
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO  
THE ABOVE LIMITATION OR EXCLUSION MAY NOT  
APPLY TO YOU. COWAY SHALL NOT BE LIABLE  
FOR ANY DAMAGES WHICH ARE BASED UPON  
NEGLIGENCE, BREACH OF WARRANTY, STRICT  
LIABILITY OR ANY OTHER LEGAL THEORY OF  
LIABILITY OTHER THAN THE EXCLUSIVE LIABILITY  
SET FORTH IN THIS WARRANTY  
Decisions as to the extent of repair or replacement  
required will be made solely by COWAY.  
The remedy under this Warranty is available only  
for that portion of the Product exhibiting defects  
at the time of the warranty claim. The replacement  
Product as well as any remaining original Product  
will be warranted only for the original one year  
warranty period. This limited warranty applies  
only to Product used for an application specified  
by COWAY for the Product and applied in strict  
accordance with COWAY published specifications  
in effect at the time of application. IF PRODUCT IS  
USED FOR OTHER THAN ITS INTENDED PURPOSE,  
IT IS SOLD AS IS AND WITHOUT ANY EXPRESS  
OR IMPLIED WARRANTIES, INCLUDING OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE.  
What This Warranty Does Not Cover:  
This Warranty warrants that the Product will be  
free from manufacturing defects which affect the  
ability of the Product to operate for its intended  
use; it is not a warranty that the Product will never  
require repairs or to undertake responsibilities,  
liabilities or obligations other than those  
specifically identified in the preceding section.  
COWAY is not responsible or liable for personal  
injury or property damage of any kind, even if  
arising from a breach of this Warranty.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Limitations on Implied Warranties:  
Waiver:  
Any implied warranty of merchantability or  
fitness for a particular purpose or use, shall be  
limited to the duration of the foregoing express  
written warranty.  
COWAY’s failure at any time to enforce or rely  
upon any of the terms or conditions stated  
herein shall not be construed to be a waiver of  
its rights hereunder.  
Conditions of Warranty:  
Obtaining Warranty Service and OWNER’S  
Duties:  
COWAY’s continuing liability under this  
Warranty is conditioned upon the following :  
a) The defect or damage is not caused  
by or is the result of : abnormal use or  
If the Product fails to operate for its  
intended purpose, then notify Coway or its  
Representative Agency within 48 hours or  
within the next business day after discovery  
of any defect in the Product. The OWNER must  
give written notice to COWAY no later than  
thirty (30) days after a defect is discovered or  
should by reasonable diligence have been  
discovered. Claims under this Warranty will  
require proof of purchase by the OWNER.  
conditions; improper storage, unauthorized  
modifications or repair; misuse, neglect,  
accident, alteration, improper installation or  
other acts that are not the fault of Coway or  
the manufacturer of the product or that are  
not covered by the manufacturer’s warranty;  
b) The Product has not been altered, modified  
or repaired without prior written approval of  
COWAY;  
c) The OWNER has notified COWAY in writing  
of any failure of the Product covered by this  
Warranty within thirty (30) days following  
such failure;  
d) There has been no misuse, abuse or  
negligence with respect to the Product on  
the part of the OWNER.  
USA  
Add  
: WOONGJIN COWAY USA, INC.  
695 SOUTH VERMONT, STE. 110(SOUTH TOWER) LOS ANGELES, CA 90005, USA  
Call center. : (213) 386-9900 / (213) 480-1600  
Fax.  
: (213) 386-3990  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MADE IN KOREA  
003  
1005760  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Clarion CD Player DXZ448R User Manual
Compaq Network Card PC CARD User Manual
Conair Electric Toothbrush WJ2B User Manual
Conair Iron GS11RH User Manual
Continental Electric Blender CP42148 User Manual
Digi Switch Hubport 4 User Manual
Duracell Battery Charger Ultra CR2 User Manual
Electro Voice Microphone RE500 User Manual
Garmin All in One Printer PRO 4900 User Manual
Global Technology Associates Network Card GB 800 User Manual