Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INFORMATION
Read All Instructions Before Using.
WARNING
For your safety, the information in this manual must be followed
to minimize the risk of property damage or personal injury.
Electricity Safety
To avoid fire or shock hazard, plug the air
cleaner directly into a electrical outlet. And
be sure the unit is in a room to protect it
from the moisture.
●
●
●
Always unplug the air cleaner before
moving it, replacing the filter, cleaning
it or whenever the air cleaner is not in
use.
Do not plug in or unplug the power
cord with wet hands or get the plug
wet to avoid electric shock.
● Never operate the air cleaner if it has
a damaged cord or plug, if it is not
working properly, or if it has been
damaged. Have the unit serviced by
a qualified man.
● Do not repeatedly plug in or unplug the
power cord.
Download from Www.Somanuals.com. All Manuals Search And Download.
03
04
● Periodically remove dust from the power
plug with a dry cloth. Dust lay on the unit
can cause bad insulation and a fire may
occur due to it.
When unplugging the power cord,
never pull the cord to plug out.
Please carry the unit by using a
handle in the back of it.
●
● Do not use to connect or transform
an electric wire without permission.
● Be sure the power cord not to be
bend by force and do not put a heavy
object on it to avoid any electric
leakage or damage.
Don’t plug in a number of electrical
goods in an outlet at the same time.
Just use the outlet for only the air
cleaner.
●
●
Please plug out, if you are not use the
unit for long time.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation & Use Safety
Never splash the air cleaner with water
to avoid the risk of electric shock.
●
●
●
●
To avoid fire hazard, never put the cord
under rugs and near heat resistors,
radiator, stoves, or heaters.
Keep the air cleaner out of direct
sunlight. The sun's heat may distort
non-metallic parts and may damage
the electric components.
It should be installed more than
20㎝ away from walls or objects,
and more than 30 ~ 60㎝ low
from the ceiling. If it is too close to
walls or objects, it could cause
contamination in the
surroundings.
Download from Www.Somanuals.com. All Manuals Search And Download.
05
06
● Do not install the air cleaner on the
inclined place and let it fall or impact.
It may cause a breakdown by an
electric shock.
● Please have the unit serviced by the A/S
center if it makes smoke or a noise.
● Do not put glasses, metals, others on the
unit.
Do not block the filter cover, the
ventilation inlet or outlet with a
paper or a cloth. It may cause the
lower performance of the product,
or the fire.
●
●
Do not let kids climb and hang on
the air cleaner.
Download from Www.Somanuals.com. All Manuals Search And Download.
Do not put acute objects such as
a gimlet in sensors of the unit.
●
●
Never use and put the flammable
gas or inflammable materials near
the air cleaner.
Never soak the unit in the water.
●
●
Do not modify, disassemble, or
repair this appliance by yourself.
Do not wipe this appliance with
benzene or paint thinner. Do not
use aerosol sprays near this
appliance.
●
Download from Www.Somanuals.com. All Manuals Search And Download.
07
08
FEATURES OF AIR CLEANER
AIR CLEANER AP-1503CHE
1. Powerful Air Cleaner
The filter system is optimized to remove
quickly pollutants. The unit contains the
HEPA filter made of Nano Silver and
Catechins which can be helpful for
removal of bacteria, minute particles.
2. Advanced Deodorizing Ability
The deodorizing ability is improved by using
AC deodorizing filter and RBD plasma
antibacterial catalysis system which can
eliminate not only harmful gases such as
volatile organic compounds(VOCs),
Ammonia, Aldehyde, but food and cigarette
odors and so on.
3. Rhythm Cleaning System by Turbo Fan
Turbo fan increases the air flow rate
and treats Indoor pollutants very quickly
by rhythm cleaning system.
4. Automatic Operation by Particle Sensor, Odor Sensor
It allows you to check the status of indoor
pollution through a particle sensor on a
real-time bases. Besides, it minimizes
electric consumption by automatically
adjusting fan speed according to the
indoor pollution degree.
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Silent Operation at Night (Sleep Mode)
It is designed to be automatically switched
to the silent operation by sensing light to
provide a quiet and pleasant environment
at the dark.
6. Safety Design for Customers
The operation of the air cleaner stops by
safety switch when the front cover is opened.
The ventilation inlet and outlet are designed
for the sake of safety to prevent the risk of
accidents.
7. RBD Plasma System &Antibacterial Catalysis Filtering
We complexly applies RBD Plasma system
and antibacterial catalysis filter which can
remove harmful gas, and the floating
bacteria. You can save the maintenance
cost because a regular cleaning can extend
the average life span of the filter, besides.
※ RBD Plasma Catalysis System generates plasma which is the 4th condition of materials.
RBD plasma system is made of the special silicon barrier for the stable electrical
discharge, and gives full play to the genius in the removal of the bacteria mold.
8. Natural Cluster Negative Ions
This air cleaner can materialize a plenty of
cluster negative ions which can make the
inside air more clean by eliminating the
activated oxygen and the static electricity.
9. Minimum of Expenses
You can cut down your expenses by using
BLDC Motor.
Download from Www.Somanuals.com. All Manuals Search And Download.
09
10
NAMES OF EACH PART
Side
▶
▶
Operation
Part
▶
▶
Odor Sensor
Ventilation
outlet
Indication
Part
▶
Filter
Cover
▶
Particle
Sensor
Rear
▶
Handle
▶
Power Cord
Download from Www.Somanuals.com. All Manuals Search And Download.
INDICATION PART
Indicator of Auto/Manual
Indicator of Air Flow Rate
It indicates whether the unit is operating
on automatic mode or manual mode.
Operating mode is selected with the
‘Auto/Manual’ button.
The unit operates automatically
according to the indoor pollution
degree on an automatic mode. You
can select the mode among the rate
from 1 to 4 step, turbo, and rhythm
cleaning mode with the ‘Air Flow’
button on a manual mode.
Indicator of Sleep Mode
It indicates the unit is operating on
sleep mode, and this mode is available
on automatic mode .
Rhythm Cleaning Indicator
It is the mode to efficiently get rid of
pollutants. The change of the air flow
can be efficiently controlled by
rhythmical operation of the unit.
Indicator of Pollution Degree
Indicator of Cluster Negative Ions
It is the mode to remove pollutants
from the inside air according to the
rhythmical operation. It efficiently
controls the change of air flow.
It indicates the discharges of cluster
negative ions with the clean air
together.
Indicator of Odor
It indicates the degree of the indoor
odor pollution.
Indicator of Air Speed
You can see the condition of the air
flow because the revolution speed
automatically changes according to
the air flow.
Indicator of Plasma
When you push ‘Plasma’ button, it
indicates the working of ‘Plasma’.
Download from Www.Somanuals.com. All Manuals Search And Download.
11
12
NAMES OF INTERNAL FILTERS
Download from Www.Somanuals.com. All Manuals Search And Download.
▶
▶
▶
●
●
●
Filter Cover
It makes filters safe in front of them. The purification ability can be well because
the filter cover is designed able to inhale the air from 5 different ways.
Natural Cluster Negative Ions
It removes the activated oxygen, the static electricity from the inside air and
helps to promote health by discharge of the cluster negative ions.
AC Deodorizing Filter
It is complexly treated by the light catalysis and the inorganic absorbent,
so it can control the harmful gas, the bad smell, Formaldehyde which is
the cause of Sick House Syndrome.
▶
●
Antibacterial Turbo Fan
It generates the pertinent inhalation ability and air flow to the floor space,
so it can bring not only the efficient control of pollution but also the
prevention of noise.
▶
▶
●
●
Antibacterial Catalysis Filter
The filter is handled by the inorganic absorbent, the light catalysis that is
useful to get rid of Formaldehyde such as bad smells, germs, harmful gas.
RBD Plasma Filter
It is the unique plasma system which can be very useful in not only the
minimum of ozone generation but also the removal of the germ and mold.
▶
▶
●
●
HEPA Filter
The HEPA(High Efficiency Particulate Air) filter is used to filter cigarette fumes,
bacteria, and minute dust.
Medium Filter
It is made of special antibacterial medium to filter large substances, mold
and bacteria bigger than 1㎛
, and to hold on the ability of the HEPA filter.
▶
●
Pre-Filter
It is made of antibacterial material and filters comparatively large dust,
hairs, pet dander, mold, and etc.
Download from Www.Somanuals.com. All Manuals Search And Download.
13
14
OPERATION PART
ON/OFF
It is used to turn on and off the unit.
Auto/Manual
The unit starts to work on the automatic mode by pushing
‘Auto/Manual’ button and the air flow rate is automatically adjusted
through particle & odor sensor depending on the indoor pollution
degree. You can choose the manual mode by pushing the button
during the auto mode, control the airflow which you want by ‘Air Flow’
button.
AIR FLOW
You can select the rate of air flow as you push this button.
(Step1→Step2→Step4→Turbo→Rhythm cleaning. Please use the
‘Turbo’ operation when the air is highly polluted.
Plasma
When the unit is in ‘RBD plasma’ mode, it can remove the odor, the
germ from the air by pushing ‘Plasma’ button.
Download from Www.Somanuals.com. All Manuals Search And Download.
PRE-OPERATING INSTRUCTIONS
WARNING
Install filters on the unit after removing their-packing sheet
Step1 Open the filter cover by pulling
the right side of the cover.
Step2 Please take out the filter by pushing
the both hooks of the filter, and
remove its
packing sheet.
�
Step3 Please install filters according to the
following order. AC deodorizing filter→
antibacterial catalysis filter→RBD plasma
filter→HEPA filter→medium filter→pre
filter(Check the insert direction of filters and
make the both hooks fixed into the unit.)
The Insert Direction
� AC Deodorizing filter
�
Antibacterial Catalysis filter � RBD Plasma filter � HEPA filter
� Medium filter
� Pre filter
Step4 Please close the filter cover.
Download from Www.Somanuals.com. All Manuals Search And Download.
15
16
HOW TO USE
In case of manual mode
Select manual mode with the "Auto/Manual"
button after turnning on the unit.
Plug the power cord to the voltage
●
rating that matches on the rating plate.
It operates on automatic mode by pushing
●
the ‘ON/OFF’ button.
�
�
Push the ‘Auto/Manual’ button.
(The ‘Manual’ light is on.)
●
Set up the air flow rate by pushing the
●
‘Air Flow’ button.
Download from Www.Somanuals.com. All Manuals Search And Download.
In case of automatic mode
The "Auto" light is lighting in the indication
part after turning on the unit.
Plug the power cord to the voltage
●
rating that matches on the rating plate.
If you push the ‘ON/OFF’ button, the unit
operates on automatic mode according to
the indoor pollution degree.
●
(The ‘Auto’ light is on in the
indication part at first.)
�
The silent operation at night
This function can only operate on automatic mode.
※ If the pollution of 1step is lasting over 10 minutes, the air flow is
lowered to 50% of 1 step.
It is a function set to be automatically
transferred to the sleep mode(Air flow rate
keeps at the ultra low fan speed.) through
a sensor detecting the luminosity of light
around the unit.
●
If you select a manual mode or the light
density is strong, sleep mode is
automatically set off.
●
Download from Www.Somanuals.com. All Manuals Search And Download.
17
18
HOW TO USE
How to adjust the pollution sensitivity
※ The unit is set at a standard sensitivity. In case that pollution degree is maintained
at the highest or the lowest level for over 2 hours after the unit starts to work,
please adjust the sensitivity of sensor as the following the way below.
Step1 Push both the ‘Auto/Manual’
and ‘Air Flow’ just over 2
seconds.
Step2 The “Pollution” light is out, and the
light stick of indication is on as in
the drawing.
Step3 You can adjust the sensitivity by
pushing ‘Auto/Manual’ button.
stage1:sensible
stage2,3:standard
stage4:insensible
�
Step4 You can confirm the sensitivity,
which you did, by pushing the ‘Air
Flow’ button.
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING METHOD
WARNING
Unplug power plug before cleaning.
Cleaning a Particle Sensor & Odor Sensor(Every 2 months)
●
Please clean the ventilation inlet and outlet
of sensors with a soft brush, or a vacuum
cleaner.
● Please wipe the lens with a
cotton swab soaked with
water and get rid of moisture
by using dry one.
�
Filter Cover Cleaning
● Please remove the dust clung to surface
with a soft brush. Clean the unit with a wet
cloth, if the unit is severely contaminated.
(Do not use an abradant.)
Body Cleaning
● Please wipe it with a soft and dry cloth. In
case that it is severely contaminated, wipe
it with a little bit wet cloth.
(Do not use an abradant.)
Download from Www.Somanuals.com. All Manuals Search And Download.
19
20
CLEANING METHOD
Cluster Ion Electrode Part Cleaning(Every 2months)
●
Please get rid of dirties on the charged body and the electric discharge pin of
the cluster with soft brush of cotton swab ion after opening a ventilation grill
with a screw driver.
�
�
Pre-Filter Cleaning(Every 2~4 Weeks)
● Please open the filter cover by pulling forward
the right side.
● Please pull the pre-filter up as in the drawing.
● Please remove dust with a vacuum cleaner
or water.
● Please install the filter to make the both
hooks fixed into the unit, and then close
the filter cover after complete dry of the
filter.
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
Unplug power plug before cleaning.
Install the RBD Plasma filter and the Antibacterial Catalysis filter
in the unit after complete dry.
RBD Plasma Antibacterial Catalysis Filter
Please open the filter cover by pulling the
right side of the cover.
●
●
●
Please take out the plasma antibacterial
catalysis filter, and then divide the filter
into two pieces by pushing both hooks
of the filter.
�
When you clean the RBD plasma filter,
please wipe the tungsten wire, the dirties
on the electrode with a wet cloth and then
make it dry with a dry cloth.
※
Never splash the water in the unit or
soak it in water.
※
Be careful about the down of the tungsten wire.
※ Please completely dry, in case that the water gets
into the inside of the filter. (If the inside is taken by
water, please use after dry over 12 hours.)
Download from Www.Somanuals.com. All Manuals Search And Download.
21
22
CLEANING METHOD
Please clean the antibacterial filter with
the brush or the vacuum cleaner after
the division from the RBD Plasma filter.
●
●
●
※
※
Be careful of damage to the filter.
Even though the filter may get
damaged such as a transformation
and minor breaks, there is no
problem for use.
Please put the antibacterial catalysis
filter together with RBD plasma filter.
Please close the filter cover after putting
the filter in the unit.
※
Please check the lnstalling Direction
of RBD plasma filter.
Download from Www.Somanuals.com. All Manuals Search And Download.
FILTER REPLACEMENT
WARNING
Unplug power plug before filter replacement.
WARNING
The period time of filter replacement should be different according
to the surrounding pollution degree of pollution, time of using.
Step1 Open the filter cover by pulling the
right side of the cover.
Step2 Separate filter that you want to
replace from the filter case.
Step3 Please put the filters in the unit with
the opposite direction, and then
close the cover after filter
replacement.
�
Download from Www.Somanuals.com. All Manuals Search And Download.
23
24
FILTER REPLACEMENT
Estimated Time of Filter Replacement and Cleaning
Item
Pre-filter
Period Time
Every 2~4 weeks
Every 2months
Every year
Method
Cleaning
Medium filter
HEPA filter
Replacement
Replacement
Cleaning
RBD Plasma filter
Every 2months
Every 6months
Every 2 years
Cleaning
Replacement
Antibacterial Catalysis
filter
AC Deodorizing filter
Every 2 years
Replacement
※
The period time of filter of replacement is based on the use of 24hours a
day at step 1 mode. And it could be different accordirg to the surroundings.
Download from Www.Somanuals.com. All Manuals Search And Download.
BEFORE ASKING A/S
Check the followings before requesting for A/S.
It can not operate properly because of trivial problems or a lack of user's
experience even if it is not out of order. In those cases, please check the
followings carefully to solve problems. Please call A/S center if you have any
problems except the followings.
Points to be
checked
Troubles
Troubleshooting
Plug the power cord to the
voltage rating that matches on
the rating plate.
Is the plug inserted?
No air comes out
Turn the power on and select
the function which you want.
Are the indication lights off?
Is the electric power off?
Operate it after the power is on.
In the automatic mode, the air
flow rate could not selected by
hand-operating.
Is the ‘Auto/Manual’ light of
the indication part on?
The air fiow rate
does not change.
In the sleep mode, you can not
operate an air flow rate.
Is the room dark?
The output of the
airflow is
considerably
weakened.
Clean the filters or replace them
after checking the period for
replacement.
Is the time of the pre-filter
cleaning passed?
Download from Www.Somanuals.com. All Manuals Search And Download.
25
26
BEFORE ASKING A/S
Points to be
Troubles
Troubleshooting
checked
Is there dust around the particle
sensor lens?
Remove the dust. ( Refer to
Page 18)
Is the degree of pollution
The degree of
Adjust the sensitivity of particle
sensor to the low. (Refer to Page
18)
indicated to the high for a long
pollution does
time?
not change.
Is the degree of pollution
indicated to the low for a long
time?
Adjust the sensitivity of particle
sensor to the high. (Refer to
Page 18)
Has the period of filter
replacement and cleaning
passed?
There is a bad
smell in a
ventilation outlet.
Clean filters or replace them.
Install the RBD Plasma filter on
the unit after checking its
formation.
Is the RBD Plasma filter
systematically put in the unit?
Is the tungsten wire down?
is twinkling
Please request for A/S.
Is the particle
sensor or the
odor sensor
is twinkling
Please request for A/S
In case other
functional
After checking problems, pull out the electric plug and request for A/S.
defects occur.
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY INFORMATION
Product Guarantee
Parts and components shall be replaced free of charge within the guarantee period if
the defects occur due to manufacturing defects in normal operation.
Contact us in case of breakdown.
In the following cases, repair work shall be charged even within the guarantee period.
▶Breakdown caused by careless operation or unreasonable repair and renovation.
▶Breakdown caused by nonperformance of the instructions specified in the manual.
Even after the expiration of guarantee period, it is possible to apply for charged repair.
Present this Letter of Guarantee whenever repair is needed.
1.
2.
3.
4.
5.
6.
7.
This Letter of Guarantee is valid only in domestic where you buy this product.
Keep this Guarantee carefully as it is not re-issued.
Guarantee Period
Product Name
Model
Coway Air Cleaner
AP-1503CHE
Serial No.
Date of Purchase
Guarantee Period
Customer’s Address
Customer’s Name
From
To
Tel.
Please contact our customer's service center in case you are not satisfied with our A/S service.
●
●
Nationwide A/S Call :
Customer counselling Center Call:
Fax :
In case any other filters or parts which are not genuine
products of Coway are used, Coway is not responsible for
any problems related to air quality.
☞
Coway Co., Ltd
658 Yoogoo-Ri, Yoogoo-Eub, Gongju-Si, Choongnam Province, Korea
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
|