Coway Air Cleaner AP 1503CHE User Manual

Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INFORMATION  
Read All Instructions Before Using.  
WARNING  
For your safety, the information in this manual must be followed  
to minimize the risk of property damage or personal injury.  
Electricity Safety  
To avoid fire or shock hazard, plug the air  
cleaner directly into a electrical outlet. And  
be sure the unit is in a room to protect it  
from the moisture.  
Always unplug the air cleaner before  
moving it, replacing the filter, cleaning  
it or whenever the air cleaner is not in  
use.  
Do not plug in or unplug the power  
cord with wet hands or get the plug  
wet to avoid electric shock.  
Never operate the air cleaner if it has  
a damaged cord or plug, if it is not  
working properly, or if it has been  
damaged. Have the unit serviced by  
a qualified man.  
Do not repeatedly plug in or unplug the  
power cord.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
03  
04  
Periodically remove dust from the power  
plug with a dry cloth. Dust lay on the unit  
can cause bad insulation and a fire may  
occur due to it.  
When unplugging the power cord,  
never pull the cord to plug out.  
Please carry the unit by using a  
handle in the back of it.  
Do not use to connect or transform  
an electric wire without permission.  
Be sure the power cord not to be  
bend by force and do not put a heavy  
object on it to avoid any electric  
leakage or damage.  
Don’t plug in a number of electrical  
goods in an outlet at the same time.  
Just use the outlet for only the air  
cleaner.  
Please plug out, if you are not use the  
unit for long time.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation & Use Safety  
Never splash the air cleaner with water  
to avoid the risk of electric shock.  
To avoid fire hazard, never put the cord  
under rugs and near heat resistors,  
radiator, stoves, or heaters.  
Keep the air cleaner out of direct  
sunlight. The sun's heat may distort  
non-metallic parts and may damage  
the electric components.  
It should be installed more than  
20away from walls or objects,  
and more than 30 ~ 60low  
from the ceiling. If it is too close to  
walls or objects, it could cause  
contamination in the  
surroundings.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
05  
06  
Do not install the air cleaner on the  
inclined place and let it fall or impact.  
It may cause a breakdown by an  
electric shock.  
Please have the unit serviced by the A/S  
center if it makes smoke or a noise.  
Do not put glasses, metals, others on the  
unit.  
Do not block the filter cover, the  
ventilation inlet or outlet with a  
paper or a cloth. It may cause the  
lower performance of the product,  
or the fire.  
Do not let kids climb and hang on  
the air cleaner.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Do not put acute objects such as  
a gimlet in sensors of the unit.  
Never use and put the flammable  
gas or inflammable materials near  
the air cleaner.  
Never soak the unit in the water.  
Do not modify, disassemble, or  
repair this appliance by yourself.  
Do not wipe this appliance with  
benzene or paint thinner. Do not  
use aerosol sprays near this  
appliance.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
07  
08  
FEATURES OF AIR CLEANER  
AIR CLEANER AP-1503CHE  
1. Powerful Air Cleaner  
The filter system is optimized to remove  
quickly pollutants. The unit contains the  
HEPA filter made of Nano Silver and  
Catechins which can be helpful for  
removal of bacteria, minute particles.  
2. Advanced Deodorizing Ability  
The deodorizing ability is improved by using  
AC deodorizing filter and RBD plasma  
antibacterial catalysis system which can  
eliminate not only harmful gases such as  
volatile organic compounds(VOCs),  
Ammonia, Aldehyde, but food and cigarette  
odors and so on.  
3. Rhythm Cleaning System by Turbo Fan  
Turbo fan increases the air flow rate  
and treats Indoor pollutants very quickly  
by rhythm cleaning system.  
4. Automatic Operation by Particle Sensor, Odor Sensor  
It allows you to check the status of indoor  
pollution through a particle sensor on a  
real-time bases. Besides, it minimizes  
electric consumption by automatically  
adjusting fan speed according to the  
indoor pollution degree.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Silent Operation at Night (Sleep Mode)  
It is designed to be automatically switched  
to the silent operation by sensing light to  
provide a quiet and pleasant environment  
at the dark.  
6. Safety Design for Customers  
The operation of the air cleaner stops by  
safety switch when the front cover is opened.  
The ventilation inlet and outlet are designed  
for the sake of safety to prevent the risk of  
accidents.  
7. RBD Plasma System &Antibacterial Catalysis Filtering  
We complexly applies RBD Plasma system  
and antibacterial catalysis filter which can  
remove harmful gas, and the floating  
bacteria. You can save the maintenance  
cost because a regular cleaning can extend  
the average life span of the filter, besides.  
RBD Plasma Catalysis System generates plasma which is the 4th condition of materials.  
RBD plasma system is made of the special silicon barrier for the stable electrical  
discharge, and gives full play to the genius in the removal of the bacteria mold.  
8. Natural Cluster Negative Ions  
This air cleaner can materialize a plenty of  
cluster negative ions which can make the  
inside air more clean by eliminating the  
activated oxygen and the static electricity.  
9. Minimum of Expenses  
You can cut down your expenses by using  
BLDC Motor.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
09  
10  
NAMES OF EACH PART  
Side  
Operation  
Part  
Odor Sensor  
Ventilation  
outlet  
Indication  
Part  
Filter  
Cover  
Particle  
Sensor  
Rear  
Handle  
Power Cord  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INDICATION PART  
Indicator of Auto/Manual  
Indicator of Air Flow Rate  
It indicates whether the unit is operating  
on automatic mode or manual mode.  
Operating mode is selected with the  
Auto/Manual’ button.  
The unit operates automatically  
according to the indoor pollution  
degree on an automatic mode. You  
can select the mode among the rate  
from 1 to 4 step, turbo, and rhythm  
cleaning mode with the ‘Air Flow’  
button on a manual mode.  
Indicator of Sleep Mode  
It indicates the unit is operating on  
sleep mode, and this mode is available  
on automatic mode .  
Rhythm Cleaning Indicator  
It is the mode to efficiently get rid of  
pollutants. The change of the air flow  
can be efficiently controlled by  
rhythmical operation of the unit.  
Indicator of Pollution Degree  
Indicator of Cluster Negative Ions  
It is the mode to remove pollutants  
from the inside air according to the  
rhythmical operation. It efficiently  
controls the change of air flow.  
It indicates the discharges of cluster  
negative ions with the clean air  
together.  
Indicator of Odor  
It indicates the degree of the indoor  
odor pollution.  
Indicator of Air Speed  
You can see the condition of the air  
flow because the revolution speed  
automatically changes according to  
the air flow.  
Indicator of Plasma  
When you push ‘Plasma’ button, it  
indicates the working of ‘Plasma’.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
12  
NAMES OF INTERNAL FILTERS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Filter Cover  
It makes filters safe in front of them. The purification ability can be well because  
the filter cover is designed able to inhale the air from 5 different ways.  
Natural Cluster Negative Ions  
It removes the activated oxygen, the static electricity from the inside air and  
helps to promote health by discharge of the cluster negative ions.  
AC Deodorizing Filter  
It is complexly treated by the light catalysis and the inorganic absorbent,  
so it can control the harmful gas, the bad smell, Formaldehyde which is  
the cause of Sick House Syndrome.  
Antibacterial Turbo Fan  
It generates the pertinent inhalation ability and air flow to the floor space,  
so it can bring not only the efficient control of pollution but also the  
prevention of noise.  
Antibacterial Catalysis Filter  
The filter is handled by the inorganic absorbent, the light catalysis that is  
useful to get rid of Formaldehyde such as bad smells, germs, harmful gas.  
RBD Plasma Filter  
It is the unique plasma system which can be very useful in not only the  
minimum of ozone generation but also the removal of the germ and mold.  
HEPA Filter  
The HEPA(High Efficiency Particulate Air) filter is used to filter cigarette fumes,  
bacteria, and minute dust.  
Medium Filter  
It is made of special antibacterial medium to filter large substances, mold  
and bacteria bigger than 1㎛  
, and to hold on the ability of the HEPA filter.  
Pre-Filter  
It is made of antibacterial material and filters comparatively large dust,  
hairs, pet dander, mold, and etc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
14  
OPERATION PART  
ON/OFF  
It is used to turn on and off the unit.  
Auto/Manual  
The unit starts to work on the automatic mode by pushing  
Auto/Manual’ button and the air flow rate is automatically adjusted  
through particle & odor sensor depending on the indoor pollution  
degree. You can choose the manual mode by pushing the button  
during the auto mode, control the airflow which you want by ‘Air Flow’  
button.  
AIR FLOW  
You can select the rate of air flow as you push this button.  
(Step1Step2Step4TurboRhythm cleaning. Please use the  
‘Turbo’ operation when the air is highly polluted.  
Plasma  
When the unit is in ‘RBD plasma’ mode, it can remove the odor, the  
germ from the air by pushing ‘Plasma’ button.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRE-OPERATING INSTRUCTIONS  
WARNING  
Install filters on the unit after removing their-packing sheet  
Step1 Open the filter cover by pulling  
the right side of the cover.  
Step2 Please take out the filter by pushing  
the both hooks of the filter, and  
remove its  
packing sheet.  
Step3 Please install filters according to the  
following order. AC deodorizing filter→  
antibacterial catalysis filterRBD plasma  
filterHEPA filtermedium filterpre  
filter(Check the insert direction of filters and  
make the both hooks fixed into the unit.)  
The Insert Direction  
AC Deodorizing filter  
Antibacterial Catalysis filter RBD Plasma filter HEPA filter  
Medium filter  
Pre filter  
Step4 Please close the filter cover.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
16  
HOW TO USE  
In case of manual mode  
Select manual mode with the "Auto/Manual"  
button after turnning on the unit.  
Plug the power cord to the voltage  
rating that matches on the rating plate.  
It operates on automatic mode by pushing  
the ‘ON/OFF’ button.  
Push the ‘Auto/Manual’ button.  
(The ‘Manual’ light is on.)  
Set up the air flow rate by pushing the  
Air Flow’ button.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In case of automatic mode  
The "Auto" light is lighting in the indication  
part after turning on the unit.  
Plug the power cord to the voltage  
rating that matches on the rating plate.  
If you push the ‘ON/OFF’ button, the unit  
operates on automatic mode according to  
the indoor pollution degree.  
(The ‘Auto’ light is on in the  
indication part at first.)  
The silent operation at night  
This function can only operate on automatic mode.  
If the pollution of 1step is lasting over 10 minutes, the air flow is  
lowered to 50% of 1 step.  
It is a function set to be automatically  
transferred to the sleep mode(Air flow rate  
keeps at the ultra low fan speed.) through  
a sensor detecting the luminosity of light  
around the unit.  
If you select a manual mode or the light  
density is strong, sleep mode is  
automatically set off.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
18  
HOW TO USE  
How to adjust the pollution sensitivity  
The unit is set at a standard sensitivity. In case that pollution degree is maintained  
at the highest or the lowest level for over 2 hours after the unit starts to work,  
please adjust the sensitivity of sensor as the following the way below.  
Step1 Push both the ‘Auto/Manual’  
and ‘Air Flow’ just over 2  
seconds.  
Step2 The “Pollution” light is out, and the  
light stick of indication is on as in  
the drawing.  
Step3 You can adjust the sensitivity by  
pushing ‘Auto/Manual’ button.  
stage1:sensible  
stage2,3:standard  
stage4:insensible  
Step4 You can confirm the sensitivity,  
which you did, by pushing the ‘Air  
Flow’ button.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING METHOD  
WARNING  
Unplug power plug before cleaning.  
Cleaning a Particle Sensor & Odor Sensor(Every 2 months)  
Please clean the ventilation inlet and outlet  
of sensors with a soft brush, or a vacuum  
cleaner.  
Please wipe the lens with a  
cotton swab soaked with  
water and get rid of moisture  
by using dry one.  
Filter Cover Cleaning  
Please remove the dust clung to surface  
with a soft brush. Clean the unit with a wet  
cloth, if the unit is severely contaminated.  
(Do not use an abradant.)  
Body Cleaning  
Please wipe it with a soft and dry cloth. In  
case that it is severely contaminated, wipe  
it with a little bit wet cloth.  
(Do not use an abradant.)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
20  
CLEANING METHOD  
Cluster Ion Electrode Part Cleaning(Every 2months)  
Please get rid of dirties on the charged body and the electric discharge pin of  
the cluster with soft brush of cotton swab ion after opening a ventilation grill  
with a screw driver.  
Pre-Filter Cleaning(Every 2~4 Weeks)  
Please open the filter cover by pulling forward  
the right side.  
Please pull the pre-filter up as in the drawing.  
Please remove dust with a vacuum cleaner  
or water.  
Please install the filter to make the both  
hooks fixed into the unit, and then close  
the filter cover after complete dry of the  
filter.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
Unplug power plug before cleaning.  
Install the RBD Plasma filter and the Antibacterial Catalysis filter  
in the unit after complete dry.  
RBD Plasma Antibacterial Catalysis Filter  
Please open the filter cover by pulling the  
right side of the cover.  
Please take out the plasma antibacterial  
catalysis filter, and then divide the filter  
into two pieces by pushing both hooks  
of the filter.  
When you clean the RBD plasma filter,  
please wipe the tungsten wire, the dirties  
on the electrode with a wet cloth and then  
make it dry with a dry cloth.  
Never splash the water in the unit or  
soak it in water.  
Be careful about the down of the tungsten wire.  
Please completely dry, in case that the water gets  
into the inside of the filter. (If the inside is taken by  
water, please use after dry over 12 hours.)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
22  
CLEANING METHOD  
Please clean the antibacterial filter with  
the brush or the vacuum cleaner after  
the division from the RBD Plasma filter.  
Be careful of damage to the filter.  
Even though the filter may get  
damaged such as a transformation  
and minor breaks, there is no  
problem for use.  
Please put the antibacterial catalysis  
filter together with RBD plasma filter.  
Please close the filter cover after putting  
the filter in the unit.  
Please check the lnstalling Direction  
of RBD plasma filter.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FILTER REPLACEMENT  
WARNING  
Unplug power plug before filter replacement.  
WARNING  
The period time of filter replacement should be different according  
to the surrounding pollution degree of pollution, time of using.  
Step1 Open the filter cover by pulling the  
right side of the cover.  
Step2 Separate filter that you want to  
replace from the filter case.  
Step3 Please put the filters in the unit with  
the opposite direction, and then  
close the cover after filter  
replacement.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
24  
FILTER REPLACEMENT  
Estimated Time of Filter Replacement and Cleaning  
Item  
Pre-filter  
Period Time  
Every 2~4 weeks  
Every 2months  
Every year  
Method  
Cleaning  
Medium filter  
HEPA filter  
Replacement  
Replacement  
Cleaning  
RBD Plasma filter  
Every 2months  
Every 6months  
Every 2 years  
Cleaning  
Replacement  
Antibacterial Catalysis  
filter  
AC Deodorizing filter  
Every 2 years  
Replacement  
The period time of filter of replacement is based on the use of 24hours a  
day at step 1 mode. And it could be different accordirg to the surroundings.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BEFORE ASKING A/S  
Check the followings before requesting for A/S.  
It can not operate properly because of trivial problems or a lack of user's  
experience even if it is not out of order. In those cases, please check the  
followings carefully to solve problems. Please call A/S center if you have any  
problems except the followings.  
Points to be  
checked  
Troubles  
Troubleshooting  
Plug the power cord to the  
voltage rating that matches on  
the rating plate.  
Is the plug inserted?  
No air comes out  
Turn the power on and select  
the function which you want.  
Are the indication lights off?  
Is the electric power off?  
Operate it after the power is on.  
In the automatic mode, the air  
flow rate could not selected by  
hand-operating.  
Is the ‘Auto/Manual’ light of  
the indication part on?  
The air fiow rate  
does not change.  
In the sleep mode, you can not  
operate an air flow rate.  
Is the room dark?  
The output of the  
airflow is  
considerably  
weakened.  
Clean the filters or replace them  
after checking the period for  
replacement.  
Is the time of the pre-filter  
cleaning passed?  
Download from Www.Somanuals.com. All Manuals Search And Download.  
25  
26  
BEFORE ASKING A/S  
Points to be  
Troubles  
Troubleshooting  
checked  
Is there dust around the particle  
sensor lens?  
Remove the dust. ( Refer to  
Page 18)  
Is the degree of pollution  
The degree of  
Adjust the sensitivity of particle  
sensor to the low. (Refer to Page  
18)  
indicated to the high for a long  
pollution does  
time?  
not change.  
Is the degree of pollution  
indicated to the low for a long  
time?  
Adjust the sensitivity of particle  
sensor to the high. (Refer to  
Page 18)  
Has the period of filter  
replacement and cleaning  
passed?  
There is a bad  
smell in a  
ventilation outlet.  
Clean filters or replace them.  
Install the RBD Plasma filter on  
the unit after checking its  
formation.  
Is the RBD Plasma filter  
systematically put in the unit?  
Is the tungsten wire down?  
is twinkling  
Please request for A/S.  
Is the particle  
sensor or the  
odor sensor  
is twinkling  
Please request for A/S  
In case other  
functional  
After checking problems, pull out the electric plug and request for A/S.  
defects occur.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY INFORMATION  
Product Guarantee  
Parts and components shall be replaced free of charge within the guarantee period if  
the defects occur due to manufacturing defects in normal operation.  
Contact us in case of breakdown.  
In the following cases, repair work shall be charged even within the guarantee period.  
Breakdown caused by careless operation or unreasonable repair and renovation.  
Breakdown caused by nonperformance of the instructions specified in the manual.  
Even after the expiration of guarantee period, it is possible to apply for charged repair.  
Present this Letter of Guarantee whenever repair is needed.  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
This Letter of Guarantee is valid only in domestic where you buy this product.  
Keep this Guarantee carefully as it is not re-issued.  
Guarantee Period  
Product Name  
Model  
Coway Air Cleaner  
AP-1503CHE  
Serial No.  
Date of Purchase  
Guarantee Period  
Customer’s Address  
Customer’s Name  
From  
To  
Tel.  
Please contact our customer's service center in case you are not satisfied with our A/S service.  
Nationwide A/S Call :  
Customer counselling Center Call:  
Fax :  
In case any other filters or parts which are not genuine  
products of Coway are used, Coway is not responsible for  
any problems related to air quality.  
Coway Co., Ltd  
658 Yoogoo-Ri, Yoogoo-Eub, Gongju-Si, Choongnam Province, Korea  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Code Alarm Remote Starter CA 411 User Manual
Compaq Personal Computer D510 e pc User Manual
Conair Electric Shaver GMT7CS User Manual
Creda Cooktop X152 User Manual
Dynex Home Theater System DX SB114 User Manual
EarthStone Indoor Fireplace BV400C 2 User Manual
Elation Professional Work Light Eled Light User Manual
Fostex Car Speaker FW187 User Manual
GE TV Converter Box IC697VAL348 User Manual
GE Washer GFWS3500L User Manual