IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234  
Telephone (800) 238-3600 Facsimile (800) 535-4231  
INSTALLATION INSTRUCTIONS, BIN STAT KIT, P/N 631500074,  
631500099, 631500108, 631500109, AND 631500116  
These Bin Stat kits apply to all “X” Series Ice makers  
Table 1. Loose–Shipped Parts  
Item No.  
Part No.  
630000837  
07578  
630460162  
630900895  
620045454 or  
620045455 or  
620045456 or  
620045457 or  
620050327  
Name  
Thermostat Asy  
Screw TC 08–32  
Installation Instruction, Thermostat  
Hex Nut 8–32 SS Keps  
Bin Stat Support  
Qty.  
1
2
1
1
1
2
3
4
5
1
1. Disconnect power.  
2. Remove front cover of the unit and the electrical box cover plate. For 22” wide units you will need to  
remove the Grill from the right side of the unit.  
3. To mount bin thermostat in electrical box:  
A. Route wires and connector through grommet in electrical box (see Figure 1).  
B. Attach bin thermostat to electrical box with two 08–32 TC screws provided (see Figure 1).  
4. Connect the bin thermostat lead to the circuit board (see Figure 2).  
5. Straighten approximately 12” of capillary tube to go through hole in chassis base. Re–coil the re-  
mainder. Do not disturb the tightly coiled end.  
6. Insert the “1/4” diameter wire Bin Stat support into the coiled end of capillary tube. Carefully wrap 5  
turns of free capillary tube tightly around the Bin Stat support. Insert the assembly through the hole  
in the chassis base. Route capillary tube to follow the Bin Stat support as closely as possible (see  
Figure 3).  
7. Slip eye of Bin Stat support over the 8–32 weld stud in the chassis base. If a nut exists on this weld  
stud remove before assembling the Bin Stat support. Secure the Bin Stat support with the 8–32  
Keps nut provided in the kit (see Figure 3).  
8. Any excess capillary tubing must be carefully pulled back into the compressor compartment to pre-  
vent ice from damaging it during dispenser operation.  
October 9, 2003  
IMI CORNELIUS INC. 2001–2003  
1
630460162  
Rev C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(White Lead)  
Condenser Sensor  
See note 1  
PRESSURE Transducer  
DELAY  
CLEAN  
ERROR  
J9  
Harvest  
RD  
Bridge  
Thickness  
pot.  
Off  
2 1  
3
Unit  
Selection  
Switch  
On  
Valve  
#8  
#7  
Micro  
FILL VALVE  
Processor  
(Manufacturing Date)  
36430001  
Off  
On  
GR  
Dump  
S31  
DUMP VALVE  
S32  
#6  
#5  
#4  
#3  
#2  
#1  
FAN MOTOR (AIR COOLED)  
GR  
Fan  
COMPRESSOR  
WATER PUMP  
HOT GAS  
GR  
Comp  
GR  
Pump  
NEUTRAL  
GR  
Gas  
POWER  
RH Evap.  
Switch  
GR  
YL  
YL  
YL  
YL  
N
S
5
4
3
2
N
S
Bin  
Switches  
LH Evap.  
Switch  
Transformer  
In  
Out  
Com  
Triac  
Stack  
Plug Bin Thermostat on Top  
Two Pins of Stacking Cable Plug  
1
Figure 2  
October 9, 2003  
630460162  
Rev C  
IMI CORNELIUS INC. 20012003  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DETAIL A  
SCALE 1:2  
BIN STAT SUPPORT  
INSERT COIL AROUND  
832 HEX  
NUT  
BIN STAT  
SUPPORT  
CAPILLARY TUBE  
SEE DETAIL  
A
BIN STAT SUPPORT  
Figure 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Conair Hair Dryer 141F User Manual
Cooper Lighting Indoor Furnishings C510R User Manual
Craftsman Automobile Parts 50136 User Manual
Creative Labs Portable Radio 500DAB User Manual
Dukane Projector 8925H RJ User Manual
DXG Technology Camcorder DXG 517V HD User Manual
Eaton Electrical Power Supply 10640205 User Manual
Everpure Water System HTS 11 User Manual
Frigidaire Air Conditioner FRP12PTT2R User Manual
Garland Range C0836 10 User Manual