IMI CORNELIUS INC.
One Cornelius Place
Anoka. MN 55303-6234
Telephone (800) 238--3600
Facsimile (612) 422--3246
INSTALLATION INSTRUCTIONS
KIT, P/N 2306
For installing Scotsman Model CM450, 500, & 650 Series Ice Makers on Remcort Model DB200 Series Ice/
Drink dispenser.
1. Bin Level Control
A. Locate and drill three (3) 5/16” diameter holes (Ref. Fig. 1).
B. Install mounting clamps.
2. Seal ice maker to top of Dispenser as follows:
A. Run a bead of RTV on the dispenser cover around the outline of the ice maker and inside edge of cov-
er opening.
B. Set ice maker onto cover and install bin level thermostat capillary tube in clamps and tighten screws
(Ref. Fig 1). Position ice maker as shown.
C. Wipe away excess RTV.
3. Secure ice maker to Dispenser with mounting brackets as show. Drill holes and install sheet metal screws
provided into ice maker cabinet and dispenser cover. Screws must not interfere with ice maker compo-
nents.
4. Install adhesive backed gasket strip to removable lid, and install with screw provided.
5. Follow the manufacturer’s instructions to complete the installation of the ice maker. Bin level thermostat
capillary tube must not interfere with agitator.
91933
1
12/9/96
Download from Www.Somanuals.com. All Manuals Search And Download.
ICEMAKER
TOP-
VIEW
FRONT WALL
OF HOPPER
THERMOSTAT
CAPILLARY TUBE
LOCATE AND ADD
CLAMP HOLE IF
NEEDED TO RETAIN
CAPILLARY TUBING
15”
4--5/8
1”
DRILL 5/16 DIA. HOLES FOR 8--32
WELD NUT
INSERT 8-32 WELL NUTS INTO 5/16
DIA. HOLES, TIGHTENING SCREWS
WILL SECURE
1--5/8
CAPILLARY TUB-
ING
6
PLASTIC TUBING
USE AS REQUIRED
LARGE CLAMP
(IF NEEDED)
BIN LEVEL THERMOSTAT CAPILLARY
TUBING ASSEMBLY
91933
3
12/9/96
Download from Www.Somanuals.com. All Manuals Search And Download.
|