COOPER LIGHTING - SURE-LITES
DIMENSIONS
DESCRIPTION
The RD Series is a recessed
emergency lighting system
designed for locations where
aesthetics are of utmost
importance. The housing is
fully recessed in dry wall or
grid ceiling installations.
Designer pinchback heads
rotate 358° and swivel 90° to
0°. Ideal for commercial and
institutional environments
where easy recessed
4 5/8"
(118mm)
8 1/4"
(210mm)
3 1/2"
6"
(RD4 Only)
(89mm) (152mm)
7" max.
(178mm)
5 1/8"
(130mm)
10 1/4" (260mm)
12 7/8" (327mm)
6 1/4" (159mm)
9 1/4" (235mm)
RD SERIES
Two Injection Molded
Thermoplastic Heads
installation and minimal
maintenance are desired.
8 1/4"
4 5/8"
(210mm)
(118mm)
The RLM Series is a recessed
system packaged in an
attractive flame-resistant
metal housing. It is the unit
of choice for installations
where a recessed product is
desired and the size and cost
of emergency lighting must
be kept to a minimum
3 1/2"
6"(RLM4 Only)
(89mm) (152mm)
9 1/4"
(235mm)
5 1/8"
(130mm)
6 1/4"
(159mm)
without sacrificing
dependability or light output.
10 1/4" (260mm)
12 7/8" (327mm)
9 1/4" (235mm)
RLM SERIES
Two High-Impact
Thermoplastic Heads
ELECTRICAL RATINGS
Rated Wattage to 87 1/2% of rated D.C. Voltage
Lamp Information
4 hours Type
Model
Battery
DC Voltage
1 1/2 hours
2 hours
3 hours
Wattage
Number
RD1
RD3
RD4
RD6
SLC
SLC
SLC
SNC
SNC
SLC
SLC
SLC
SLC
SNC
SNC
6
6
12
6
6
6
6
6
12
6
18
27
54
15
24
10.8
18
27
54
15
24
15
24
-
12
18
7.2
15
24
-
10
18
-
8
12
-
10
18
-
8
12
8
14
-
6
10
-
8
14
-
-
10
Tungsten Halogen
Tungsten Halogen
Incandescent
Tungsten Halogen
Tungsten Halogen
Incandescent
Incandescent
Incandescent
Incandescent
Incandescent
6
12
9
29-12
29-66
029-86
29-12
29-66
29-121
29-84
29-84
029-86
29-88
29-88
Recessed Housing
EMERGENCY LIGHT
6
RD7
12
5.4
9
9
9
RLM1
RLM2
RLM3
RLM4
RLM8
RLM9
• Dual-voltage input
120/277VAC, 60Hz
12
18
7.2
7.2
6
Incandescent
SLC=Sealed Lead Calcium Battery
SNC=Sealed Nickel Cadmium Battery
• 20 gauge die-formed steel
housing with white powder
coat finish
ORDERING INFORMATION
SAMPLE NUMBER: RD1V
• Heads match housing
finish
• Knockout, conduit or cord
set
Options
Accessories
Model Number
(Add as suffix)
A=Ammeter(2)
(Order separately)
WG2 =Wire Guard
WG7 =Wire Guard
VS=Choose polycarbonate
vandal shield desired
from accessories
sheet
RD1
RD3
RD4
RD6
• Supplied with hanger bars,
T-Bar clips
SD=Self-Diagnostics
TDM=Time Delay Monitor
V=Voltmeter(2)
Alternate Lamps(1)
Other Options(1)
• Single modular electrical
connector
RD7
RLM1
RLM2
RLM3
RLM4
RLM8
RLM9
• Remote capability
• Line-latching, Solid-State
voltage limited charger,
Solid-State switching,
low- voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test
switch/power indicator
light
Energy Data
Input Current (Max.):
Model No.
RD1, RD3
RD4, RLM4
RD6
120V
.12A
.30A
.06A
.07A
.12A
.06A
.07A
277V
.05A
.13A
.03A
.04A
.05A
.03A
.04A
RD7
• UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes
RLM1, RLM2, RLM3
RLM8
RLM9
(1) Consult your Cooper Lighting Representative. (2) Provision for one meter only.
606 COOPER LIGHTING
Download from Www.Somanuals.com. All Manuals Search And Download.
|