VAPOR-TIGHT
WALL MOUNT
INSTALLATION INSTRUCTIONS
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
Warning:
5/01
IMI-447
• FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN
SERIOUS INJURY OR DEATH
• This fixture is not suitable for Hazardous
or Classified Locations. Disconnect all
electrical power before installation or
servicing.
• This product must be installed in
accordance with the applicable installation
code by a person familiar with the
construction and operation of the product
and the hazards involved. Consult a
qualified electrician to ensure correct
branch circuit conductor.
• Not for use above cooking equipment.
For Models:
ICVW1 Series
FIXTURE
(200 Watt / 120 Volt) 1/2 NPS
ICVW2 Series
(300 Watt / 120 Volt) 3/4 NPS
BLACK
LINE (HOT)
WHITE
NEUTRAL
GROUND
GREEN/GROUND
Ground Screw
Instructions:
•
Disconnect all electrical power from the source as per the
NEC.
Mounts to Standard
J -Boxes when
Desired.
➔
Turn off and lock circuit breakers and remove fuses
protecting the circuit.
•
•
•
Complete connections as per the diagram and the NEC
using approved methods and devices. Proper grounding
must include ground screw and ground wire.
A surface mounted fixture requires the use of caulking
compounds to provide a moisture tight seal. Use RTV
silicone sealant.
Ground Screw
Connection when
Standard J -Box
Desired
Not Required in
Som e Applications
Relamp with proper wattage lamp only -- allow fixture to
cool for relamping.
➔ Lamps: (Sizes vary by manufacturer, so caution must
be taken with Max Lamp Sizes stated.)
ICVW1: 200W MAX; A21 MAX; 120V MIN
ICVW2: 300W MAX; PS25 MAX; 120V MIN
Min Supply Conductor Requirements.
ICVW1: 75ºC
•
ICVW2: 90ºC
Applications:
• Suitable for operation in Ambients not exceeding 40ºC.
• Suitable for Wet Locations.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.
LUMARK
1121 HIGHWAY 74 SOUTH PEACHTREE CITY, GEORGIA 30269
5/01
IMI-447
ADH010709
Download from Www.Somanuals.com. All Manuals Search And Download.
|