INSTALLATION INSTRUCTIONS  
V90229-1T  
COMBOLIGHT  
R
TRIMMED  
Avoid Fire or Electric Shock  
  
Page 1 of 3  
THIS PRODUCT MUST BE INSTALLED IN  
ACCORDANCE WITH THE APPLICABLE  
INSTALLATION CODE BY A PERSON  
FAMILIAR WITH THE CONSTRUCTION AND  
OPERATION OF THE PRODUCT AND THE  
HAZARDS INVOLVED.  
*Installation Instructions for qualified electricians only.  
*Install per National Electrical Code and local regulations.  
*Read Installation Instructions completely before installation.  
*Failure to follow Installation Instructions may void warranties.  
FIXTURE MOUNTING:  
1. Fixture must be mounted using either BUTTERFLY MOUNTING  
BRACKETS or HANGER BARS (Contact RSA Dealer for HANGER BARS).  
INSTALLATION NOTE:  
DO NOT install insulation within 3in of any part of the Luminaire.  
Blinking light of this thermally protected Luminaire may indicate overheating.  
BUTTERFLY MOUNTING:  
2. Fixture comes equipped with universal BUTTERFLY MOUNTING  
BRACKETS that can take common 1" or 1-1/2" black iron or galvanized  
MOUNTING CHANNELS (supplied by others). See Fig 1.  
SCREW  
JBOX COVER  
JBOX  
3. Position fixture so the MOUNTING CHANNELS lie on top of the ceiling  
runners.  
Figure 2  
4. Fasten MOUNTING CHANNELS securely to ceiling runners.  
9. A clean, square hole in the CEILING MATERIAL must be cut. Install the  
ceiling material below housing as seen in Fig 4.  
5. Secure MOUNTING CHANNELS to universal BUTTERFLY MOUNTING  
BRACKETS with wire tie downs.  
10. Replace the TRIM into the HOUSING by connecting the TORSION  
SPRINGS to the HOUSING. Push the TRIM into the HOUSING until flush  
with the CEILING MATERIAL as seen in Fig 4.  
6. The BUTTERFLY MOUNTING BRACKETS are height-adjustable and  
should be set so that the APERTURE COLLAR will be flush with the  
finished ceiling plane.  
HOUSING  
MOUNTING  
CHANNEL  
TORSION  
SPRING  
BUTTERFLY  
MOUNTING  
BRACKETS  
TRIM  
Figure 3  
HEX  
SCREW  
Figure 1  
ELECTRICAL:  
7. Remove the JBOX COVER from the JBOX by removing the four SCREWS.  
Connect supply lead wires to junction box lead wires in accordance with  
your local electrical code(s) or N.E.C. Replace JBOX COVER onto JBOX,  
securing with SCREWS. See Fig 2.  
CEILING MATERIAL INSTALLATION:  
HOUSING  
8. Pull the TRIM away from the HOUSING. The TORSION SPRINGS will hold  
the TRIM onto the HOUSING. Compress the TORSION SPRINGS on each  
end of the TRIM, releasing the TRIM from the HOUSING. See Fig 3.  
TRIM  
CEILING  
MATERIAL  
Figure 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
V90229-3  
COMBOLIGHT  
R
LAMPHOLDER  
Avoid Fire or Electric Shock  
  
Page 3 of 3  
THIS PRODUCT MUST BE INSTALLED IN  
ACCORDANCE WITH THE APPLICABLE  
INSTALLATION CODE BY A PERSON  
FAMILIAR WITH THE CONSTRUCTION AND  
OPERATION OF THE PRODUCT AND THE  
HAZARDS INVOLVED.  
*Installation Instructions for qualified electricians only.  
*Install per National Electrical Code and local regulations.  
*Read Installation Instructions completely before installation.  
*Failure to follow Installation Instructions may void warranties.  
19. To replace the COVER RING:  
Push the COVER RING onto the BACK RING by lining up the  
BAYONET SLOTS (see Fig. 11) with the two (2) PINs in the BACK RING.  
GIMBAL BRACKET  
(Standard Position)  
PIN  
BACK RING  
BAYONET  
SLOTS  
GIMBAL BRACKET  
(Rotated 180° to  
"Down" Position)  
COVER  
RING  
Figure 9  
Figure 11  
17. Once removed, flip the two (2) GIMBAL BRACKETs around (180°) and  
tighten the joint if necessary. See Fig. 9.  
If necessary, please see Step 21 for gimbal tightening instructions.  
20. Once lined up, push straight back until the COVER RING stops, then  
while keeping the COVER RING pushed back, turn clockwise until it  
pushes forward again slightly. See Fig. 12.  
18. Reinsert the lamp ring assembly by turning it counter-clockwise into the  
SLOTs on the GIMBAL BLOCKs. Re-tighten the two (2) SET SCREWs  
in the GIMBAL BLOCKs. The lamp ring assy should now be oriented in  
the "up position". See Fig. 10.  
GIMBAL RING  
GIMBAL  
BLOCK  
SNOOT  
COVER RING  
(AS INSTALLED)  
Figure 12  
21. Gimbal tightening instructions:  
The lamp ring is intended to give positive tension at the PIVOT JOINTS  
so the lamp ring can be aimed by hand and held in place by tension.  
*If a stronger, more secure lock is required then the PIVOT JOINTS (hex  
screws) may be tightened clockwise with a hex wrench tool. See Fig. 6.  
*Please note that in some conditions the COVER RING will need to be  
removed to gain access to the inner PIVOT JOINTS.  
SLOT  
SET SCREW  
Figure 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Craftsman Lawn Mower 48624586 User Manual
Craftsman Sander 31527984 User Manual
Craftsman Snow Blower 53688502 User Manual
Cres Cor Convection Oven CO 151 FUA 12B User Manual
CyberData Microphone VoIP Multicast Microphone User Manual
Dual Marine Radio AM400W User Manual
Dual Speaker DC265 User Manual
Electro Voice Speaker MB500 User Manual
Garland Convection Oven MCO E 25 C User Manual
GE Monogram Trash Compactor ZCG3100VBB User Manual