FAIL-SAFE
Type
DESCRIPTION
The VRVT2 Series is an energy efficient industrial Vaportite fixture that
features rugged and durable construction. The VRVT2 incorporates a full
metal fixture liner inside a reinforced fiberglass housing with a high impact
diffuser. This Vaportite series is suitable for interior and exterior
applications and can be surface or chain mounted.
Catalog #
Project
Date
Comments
Prepared by
The VT2 Series has been designed for maximum operation in commercial
institutional and industrial environments where weathering, high
temperature, humidity and dust or corrosive fumes are present.
SPECIFICATION FEATURES
A ... Construction
B ... Electrical*
C ... Reflectors
Fiberglass housing is reinforced
polyester and self-extinguishing
(ASTM-D635-74) plastic of a
permanent pearl gray color. Top of
housing has thirteen (13)
Unit has full metal liner (channel)
secured by brass internal/external
mounting studs for positive
grounding, maximum protection
and rigidity. Ballasts are CBM/ETL
Class "P" certified suitable to
minus 20°F. Spring loaded
lampholders. Electrical
"DR" - Clear low brightness pattern
acrylic with 15% high impact
additive.
"DR-100" - Clear low brightness
pattern acrylic with 100% high
impact additive.
embossments (8' unit), providing
mounting flexibility on uneven
surfaces. A watertite hub for 1/2"
conduit entry is provided at each
end of housing (standard) for
continuous feed. Polyurethane
gasketing is formed in the housing
providing a continuous seamless
seal for the diffuser. Twelve (8'
unit) sturdy cam latches with
integral stainless steel TORX
screws clamp diffuser tightly for a
positive seal between housing,
gasket and diffuser.
Example: VRVT2-296HODR-100
"LEX" - High impact clear low
brightness pattern polycarbonate.
LEXAN
components and fixtures are
UL/CUL listed for Wet Locations.**
Example:VRVT2-296HOLEX.
A
B
C
VRVT2
196HO
196T8HO
296HO
5-7/8"
[149mm]
296T8HO
8' INDUSTRIAL
1 or 2 LAMPS
HIGH OUTPUT, 800MA
Vandal Resistant Luminaire
7" [178mm]
LAMP CONFIGURATIONS
Z
Y
Z
Y
5-7/8"
[149mm]
5-7/8"
[149mm]
ENERGY DATA
X
X
X=3"
Z=1-1/2"
[38mm]
X=3"
Z=1-1/2"
[38mm]
W=2-5/8"
[67mm]
W
6-5/8"
[168mm]
7"
Input Watts:
[76mm]
Y=3-3/16"
[81mm]
[76mm]
Y=3-3/16"
[81mm]
6-5/8"
[168mm]
7"
EB Ballast & STD Lamps
[178mm]
296HO (208)
[178mm]
296HOT8 (160)
STD Ballast & STD Lamps
MOUNTING DATA
196HO (82)
248HO (145)
89-1/2" [2273mm]
Optional Back Hub
Locations
STD Ballast & STD Lamps
296HO (237)
87-1/16" [2211mm]
1/4" x 28" Stud
(4 Places)
Luminaire Efficacy Rating
LER = FI-50
Catalog Number: VRVT2-296HO DR-WL
6-5/8"
[168mm]
X=5-17/32"
X
40-13/16"
[1037mm]
5-1/8"
[130mm]
97-13/16" [2484mm]
40-13/16"
[1037mm]
Y
[141mm]
Yearly Cost of 1000 lumens,
Y=5-17/32"
[141mm]
3000 hrs at .08 KWH= $4.80
INSTALLATION DATA
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
** Not Suitable for Wet Locations if EL4
Option is added. Consult Pre Sales Technical
Support.
OPTIONAL CHAIN HANGING SET
(VT2-CHAIN/SET-U)
MOUNTING BRACKETS
Includes 6 ft. of chain, 4 large S-Hooks and
4 small S-Hooks
Furnished
Two per 2' and 4' Unit
Four per 8' Unit
Order One (1) Kit for each 2' or 4' Fixture
Two (2) Kits Recommended For 8' Fixture
Specifications and Dimensions subject to change without notice.
ADC041525
04/18/2007 7:55:33 AM
Consult your representative for additional options and finishes.
Download from Www.Somanuals.com. All Manuals Search And Download.
VRVT2
PHOTOMETRICS
Coefficients of Utilization
Effective floor cavity reflectance
Candela
20%
50%
Angle
0
Along II
45o
2279
2260
2229
2155
2034
1834
1529
1209
952
697
644
477
249
87
Across
2279
2329
2354
2361
2322
2182
1902
1596
1320
1043
1027
868
588
291
87
rc
rw
RCR
0
80%
70%
30%
10%
0%
0
2279
2260
2144
1958
1697
1360
935
496
176
23
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
10
20
80 80 80 80
71 66 63 59
63 57 51 47
57 49 43 38
52 43 37 32
48 38 32 27
44 34 28 23
41 31 24 20
38 28 22 18
35 26 20 16
33 23 18 14
76 76 76 76
67 64 60 57
60 55 50 45
55 47 42 37
50 41 35 31
45 37 31 26
42 33 27 22
39 30 24 20
36 27 21 17
33 25 19 15
31 23 17 14
71 71 71
59 56 54
50 46 43
44 39 35
38 33 29
34 29 25
31 25 21
28 22 19
25 20 17
23 18 15
21 17 13
65 65 65
54 52 50
46 43 40
40 36 33
35 31 28
31 27 23
28 24 20
26 21 18
23 19 16
21 17 14
20 16 13
60 60 60
50 48 47
43 40 37
37 34 31
33 29 26
29 25 22
26 22 19
24 20 17
22 18 15
20 16 13
19 15 12
58
44
35
29
24
20
18
15
13
12
11
30
1
40
2
50
3
60
||
4
70
5
80
6
90
7
20
100
110
120
130
140
150
160
170
180
VRVT2-296HO DR-WL
Energy Saving Ballast
8
9
9
4
10
F96T12/CW/HO/EW
Lamps
8000 Lumens
3
4
24
Zonal Lumen Summary
4
7
21
4
3
4
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.6 x
mounting height
Zone
0-30
Lumens
1873
%Lamp
11.7
%Fixture
16.9
3
3
3
0
0
0
0-40
3187
19.9
28.8
0-60
6152
38.4
55.6
0-90
9276
58.0
83.9
Efficiency 69.1%
90-180
0-180
1783
11.1
16.1
Test Report
#ITL44181
11059
69.1
100.0
LER = FI-50
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.80
ORDERING INFORMATION
SHIPPING INFORMATION
Catalog No.
Wt.
20 lbs.
VRVT2-196T8HO DR-WL
VRVT2-296T8HO DR-WL
20 lbs.
Specifications and Dimensions subject to change without notice.
Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADC041525
04/18/2007 7:55:33 AM
Download from Www.Somanuals.com. All Manuals Search And Download.
|