Cooper Lighting Indoor Furnishings 1487 User Manual

®
FAIL-SAFE  
DESCRIPTION  
DIMENSIONS  
The Fail-Safe SCF Series is  
designed for use in horizontal  
or non-laminar air flow clean  
rooms and features the added  
convenience of field retrofitting  
for flange or grid  
installations.The enclosed and  
gasketed housing and outside  
flanged door protect against  
infiltration of airborne bacteria.  
Fixture tested to 100 PSI hose  
down. Higher ratings available  
(consult factory). The mitered  
edges on the door frame and  
the hole-free design of the  
housing prevent air exchange  
between the fixture and  
plenum, allowing re-lamping  
without contamination of the  
clean areas. UL Listed Wet  
Location. These luminaires are  
manufactured in accordance  
with U.S.D.A., F.D.A., N.S.F. and  
Federal Standard 209E. The  
SCFSeries is suitable for use in  
I.E.S. Class 10 (M2.5), 100 (M  
3.5) 1,000 (M 4.5), 10,000 (M  
5.5) and 100,000 (M 6.5) clean  
room environments.  
A
B
CEILING OPENING  
DOOR FRAME  
SCF  
C  
1 7 W - 1 6 0 W  
One piece stainless steel  
door frame and housing  
trim flange with extruded  
closed cell silicone  
Extruded aluminum mitered  
door frame and housing trim  
flange with extruded silicone  
rubber perimeter gasketing  
D
Fluorescent  
1' x 2', 1' x 4', 2' x 2', 2' x 4'  
perimeter gasketing  
SPECIFICATION GRADE  
FLUORESCENT FLANGE  
OUTSIDE FLANGED DOOR  
A
B
C
D
SCF/12  
1' x 2'  
SCF/12  
1' x 4'  
SCF/24  
2' x 2'  
SCF/24  
2' x 4'  
3 7/16"  
(87mm)  
3 7/16"  
(87mm)  
3 11/16"  
(94mm)  
3 11/16"  
(94mm)  
11 11/16"  
(297mm)  
11 11/16"  
(297mm)  
25 1/2"  
(648mm)  
25 1/2"  
(648mm)  
12 1/4"  
(311mm)  
12 1/4"  
(311mm)  
24 1/4"  
(616mm)  
24 1/4"  
24 1/2"  
(622mm)  
48 1/2"  
(1232mm)  
24 1/2"  
(622mm)  
48 1/2"  
(1232mm)  
• Lens is clear extruded  
with prisms positioned  
inside fixture and smooth  
surface on the outside for  
easy cleaning  
(616mm)  
• Flush mounted, stainless  
steel machine screws  
ORDERING INFORMATION  
SAMPLE NUMBER: SCF-12-340-277-IK12-LE3-ALP-GLR  
• Nominal 5” deep  
recessed one-piece 20 ga.  
CRS housing  
Width  
12=12"  
24=24"  
Voltage  
Lens Type  
IK12=K-12 Prismatic  
Acrylic  
IP12=K-12 Prismatic  
Polycarbonate  
KSH251=Bat Wing  
Distribution  
Ballast  
LE3=Energy  
Saving  
Door/Finish  
Options  
ALP=Aluminum  
Door & Trim/ GLR=Fuse and  
Polyester Holder  
Powder Finish RIF=Radio  
ALX=Extruded Frequency  
Options  
EBP=Emergency  
Battery Pack  
Series  
SCF=Specification  
Grade  
• Unique, Particulock™  
lens retention system.  
Lens is hermetically  
sealed to door frame  
120=120V  
277=277V  
347=347V  
UNV=120V  
Ballast  
Cleanroom  
Flange Type  
Electronic  
Ballast2  
EB81=(1) Ballast  
for use  
with T8  
Lamp  
EB82=(2) Ballasts  
for use  
with T8  
Lamp  
EB21=(1) Ballast  
for use  
with T12  
Lamp  
EB22=(2) Ballasts  
for use  
through  
277V  
Lamp Type  
2' Fixture Length  
T8 Fluorescents  
117=(1) 17W Lamp  
217=(2) 17W Lamps  
317=(3) 17W Lamps  
417=(4) 17W Lamps  
93=Prismatic  
Tempered Glass  
Aluminum  
Door &  
Trim/Clear  
Anodized  
Interference  
Filter  
• Optional extruded  
aluminum, mitered, fully  
gasketed, outside flanged  
door; or one-piece, die-  
formed stainless steel  
door and housing trim  
flange  
Housing Options  
SHN=Stainless  
Finish  
Steel, Brushed  
ALXP=Extruded  
Aluminum  
Door & Trim/  
Polyester  
304 Finish  
SHP=Stainless Steel,  
Polyester  
T12 Fluorescents  
120=(1) 20W Lamp  
220=(2) 20W Lamps  
320=(3) 20W Lamps  
420=(4) 20W Lamps  
Powder Finish  
Powder Coat  
Finish  
(Standard)  
• Standard Class P,  
CBM/ETL ballast  
ALH=Aluminum,  
Polyester  
Powder Finish  
U Lamps  
• MicroSealTM gasketing  
system features silicone  
RTV sealant sealing lens  
to door frame and  
extruded silicone rubber  
gasketing seals door to  
housing and housing to  
ceiling  
with  
2U 1 5/8=(2)31WT8 Lamps  
3U 1 5/8=(3) 31WT8 Lamps  
2U6T8=(2)32WT8 Lamps  
2U6=(2)40WT12Lamps  
T12Lamp  
EBX1=(1) Ballast  
for use  
with  
Biaxial  
Lamp  
Biaxial Fluorescents  
140BX=(1) 40W Lamp  
240BX=(2) 40W Lamps  
340BX=(3) 40W Lamps  
EBX2=(2) Ballasts  
for use  
with  
Biaxial  
Lamp  
Accessories  
4' Fixture Length  
T8 Fluorescents  
132=(1) 32W Lamp  
232=(2) 32W Lamps  
332=(3) 32W Lamps  
432=(4) 32W Lamps  
(Order Separately)  
MFCF12-4FT=Mounting  
Frame  
• Gasketed access plate  
with two flattened, 7/8"  
diameter knockouts  
(not required  
for installation)  
MFCF24-4FT=Mounting  
Frame (not  
• Lamps by others  
T12 Fluorescents  
required for  
installation)  
140=(1) 40W Lamp  
240=(2) 40W Lamps  
340=(3) 40W Lamps  
440=(4) 40W Lamps  
Notes: For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change  
without notice.  
1 The KSH25 provides improved visual performance and wide angle distribution. This lens has an integral prism pattern designed so that  
prisms face the lamp cavity and still supply superior photometrics. Highly recommended for all high tech manufacturing environments. 2  
For specific electronic ballast, specify brand and catalog number.  
1487  
COOPER LIGHTING  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cuisinart Blender MP 14C User Manual
Cuisinart Water System IB 8895A User Manual
Curtis Network Card AR B1682 User Manual
Delta Electronics Power Supply SI54 User Manual
Ducane Gas Grill 27010357 User Manual
Elation Professional Landscape Lighting Q7 IP User Manual
Fisher Marine GPS System 00275 8026 0001 User Manual
GE Dishwasher GHDA300 User Manual
GE TV Video Accessories WJRR4170G User Manual
Glen Dimplex Home Appliances Ltd Microwave Oven 82757900 User Manual