Cobra Electronics Automobile Battery Charger CJIC 250 User Manual |
CJIC 250
Introduction
1
2
3
Thank you for purchasing the Cobra CJIC 250
jump starter/power pack with built-in air
compressor. Properly used, this Cobra product
will give you many years of reliable service.
Easy-to-use and designed for reliable
service, the 100W Mobile power pack can
run many AC appliances and 12V DC
appliance whenever you need power for
work or play, at home or on the road.
Jump Starter/PowerPack
with Air Compressor
Operating Instructions
The Cobra line of quality products includes:
CB Radios
®
microTALK Radios
Important: Please be sure to read and save
the entire manual before using your mobile
power pack. Any misoperation or misusing
may damage the equipment or create
hazardous conditions for the user. Please
keep this manual for future reference.
Radar/Laser Detectors
®
Safety Alert Traffic Warning Systems
®
HighGear Accessories
®
CobraMarine VHF Radios
What’s Included with Your CJIC 250
Power Inverters
Accessories
1. Power pack with jump start cables with
built-in air compressor
2. 120V AC charging adapter
3. Owner’s operating instructions
4. Inflation nozzles
For more information or to
order any of our products,
please visit our website:
4
©2009 Cobra Electronics Corporation
Version C
®
Printed in China
Nothing Comes Close to Cobra
Part No. 480-549-P
A1
Download from Www.Somanuals.com. All Manuals Search And Download.
How to Use Your
Cobra CJIC 250
Contents
Introduction...........................................................................................A1
Our thanks to you
Features of This Product
• 100W AC output for operating
household appliances
What’s included
Buttons, Switches & Indicators..................................................A2
Customer Assistance......................................................................A3
Conventions ........................................................................................2
Safety Information ............................................................................3
Controls and Indicators...................................................................6
Operation..................................................................................................8
AC appliances......................................................................................8
Operating AC appliances................................................................9
Some devices you can power up.................................................9
Low battery shut down....................................................................9
Overloads & high temperature protection..............................9
High surge appliances......................................................................9
Problem appliances .......................................................................10
12V DC appliances ..........................................................................10
Operating DC appliances..............................................................10
USB devices........................................................................................11
Using the Air Compressor............................................................11
Inflating tires ....................................................................................12
Inflating small sports equipment .............................................13
Jump starting a vehicle’s engine................................................14
Recharging the power pack battery.........................................15
Troubleshooting...................................................................................16
Specifications .......................................................................................18
Product service....................................................................................19
Warranty Information.......................................................................20
• 260 PSI air compressor
• 12 Volt DC power outlet for DC
accessories & appliances
• LED super bright emergency
light
• 5V USB port to power up or
charge cellphones, PDAs or
consumer electronic devices
• 1200 Watt (300A) instant
starting power to start vehicles
• Rechargeable internal battery
• LED display indicates the
battery capacity
• Reverse polarity connection
indication & alarm
• On/off safety switch
• Heavy duty cables and clamps
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Introduction
Important Safety Instructions
WARNING: Charge unit fully prior to use.
Important: Please be sure to read and save the entire manual before using your
mobile power pack. Any misoperation or misusing may damage the equipment
or create hazardous conditions for the user. Please keep this manual for future
reference.
Keep unit clear of fire and water. The 100W mobile power pack is not
intended for use in connection with life support systems or other medical
equipment or devices.
WARNING: Shock hazard.
Keep away from children. The power pack generates the same potentially
lethal AC power as a normal household wall outlet. Do not insert foreign
objects into the AC outlet, the DC power pack socket, the jump start cable
port, or the ventilation hole, do not expose this product to water, rain, snow,
condensation, or spray. Do not open the power pack expect to replace the
internal battery. Have a qualified technician perform any service work.
The following conventions are used in this manual:
WARNING Warnings identify conditions that could result in personal
injury or loss of life.
CAUTION Cautions identify conditions or practices that could result
in damage to the unit or to other equipment.
WARNING: Explosion hazard
Do not use this product where there are flammable fumes or gases, such as
in the bilge of a gasoline-powered boat, or near propane tanks. Do not use
this product in an enclosure containing automotive-type lead-acid batteries.
These batteries, unlike the sealed AGM battery in power pack, vent explosive
hydrogen gas which can be ignited by sparks from electrical connections.
When working on electrical equipment, always ensure someone is nearby to
help you in an emergency.
NOTE: These notes describe an important action item or an item that you
must pay attention to.
Abbreviations and Acronyms:
A
Ampere
WARNING: Heated surface
AC
Ah
DC
LED
mA
V
Alternating Current
Amp-hours
Direct Current
light-emitting diode
milli-Ampere
Volt
Ensure at least 2”(5cm) air space is maintained on all sides of the power
pack. During operation, keep away from materials that may be affected by
high temperatures such as blankets, pillows and sleeping bags.
WARNING: Fire hazard
Never allow jump start cables’red and black clamps to touch each other or
another common metal conductor. This could cause damage to the unit
and/or create a sparking/explosion hazard. Always disconnect the jump start
cables from the unit after use and clip the plastic guard over the jump start
cable port.
Jump start cable clamps must be connected positive to positive (red clip to
battery“+”) and negative to negative (black clip to battery “-“or engine
ground). A reverse polarity connection (positive to negative) may cause
damage to the unit and/or create a sparking/explosion hazard.
W
Watt
2
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Introduction
7. Someone should be within range of your voice, or close enough to come to
your aid when you work near batteries.
WARNING: Fire hazard
The jump start feature is designed for short term operation only- less than 5
seconds. Operating the jump start feature for more than 5 seconds may
cause damage to the unit. Allow the power pack to cool down for at least 3
minutes after each jump start.
8. Have plenty of fresh water, soap and a supply of baking soda on hand in
the area of the batteries in case of contact with battery acid. Baking soda
neutralizes lead acid battery electrolyte.
WARNING: Risk of explosion, fire or burns
9. The product is supplied with a rechargeable, sealed lead acid battery. This
battery is self contained and not consumer replaceable. Batteries must be
disposed of properly when they no longer hold a charge. Proper charging
practices will increase the life of the batteries.
The battery terminals exposed at the jump start cable port have enough
energy present to cause a spark, creating an explosion hazard, or to cause
burns if a metal object contacts both terminals. Always clip the plastic guard
over the port when not in use.
For information on battery recycling call toll free 800-822-8837.
CAUTION: Equipment damage
Do not expose the power pack to temperatures over 104° F(40° C) or under
14° F(-10° C).
Precautions when working with batteries
WARNING: Explosion and fire hazard
1. Follow all instructions published by the battery manufacturer and the
manufacturer of the equipment in which the battery is installed.
2. Make sure the area around the battery is well-ventilated.
3. Never smoke or allow a spark or flame in vicinity of the engine or
batteries.
4. Be careful not to drop a metal object on the battery or allow a metal tool
to simultaneously touch the positive and negative cable ends or battery
terminals. It might spark or short-circuit the battery or other electrical
parts and cause an explosion.
5. Remove personal metal items such as rings, bracelets, necklaces, and
watches when working with batteries. Batteries produce a short-circuit
current high enough to weld a ring or other similar objects to metal,
causing a severe burn.
6. If you need to remove a battery, always remove the negative terminal
from the battery first. Make sure all accessories are off so you don’t cause
an arc.
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Controls and Indicators:
Introduction
Red LED indicates jump start connection to battery
9. Reverse polarity
indicator
is incorrect.
1. USB power port
Provides 5 volts output for consumer
electronics devices.
10. 120V AC power
switch
When this switch is on, the 120V AC is available at
the 120V AC socket.
2. USB power indicator Illuminates when USB port is in use.
11. 120V AC socket
12. LED lights
Power outlet for AC accessories.
3. USB/LED power switch If the switch is flipped left, the USB port can
provide power. Flipped right, the white LED lamps
illuminate. Center position, the USB port and LED
lamps are off.
Four white LED lights for emergency use.
Easy-access output port to charge 12V accessories.
13. 12V DC socket
Note: The unit contains 15A fuse for over current protection.
Note: It is recommended that you use the unit to power 12V accessories less
4. Charging indicator
2-color LED indicator. When the battery is being
charged, this LED indicator lights red, when the
battery is fully charged, the LED indicator lights
green.
than 8A.
14. Jump start power
switch
Turn this switch after connecting to vehicle to
jump start battery.
15. Red battery clamp
Positive connector for jump starts.
5. Charging jack
Charge the battery in the unit by inserting the
connector from the AC charging adapter into this jack.
16. Black battery clamp Negative connector for jump starts.
Note: Be sure that the jump start switch is in off position prior to connecting
clamps to vehicle’s battery. Attach clamps properly to battery (red to positive post,
and black to negative chassis ground) before turning jump start switch to on.
6. Battery level indicators:
Battery Value
U<12.2V
Display Mode
Only red LED indicator lights.
Red and yellow LED light.
17. Portable handle
For convenient handling of unit.
12.2V<U<12.4V
12.4V<U<12.6V
U>12.6V
18. AC charging adapter: Input voltage: 120V AC
Output voltage: 13.5V DC
Red, yellow and one green LED light.
Red, yellow and two green LED all light.
Input current: 0.3A
19. 260 PSI air
compressor
Use to inflate tires and small sports equipment.
Note: It is recommended that you should check the battery voltage every 30
minutes during charging.
Note: It is recommended that you charge the interior battery using the AC
charging adapter, which offers charge protection.
7. Battery level button When pressed, indicates the battery charge levels.
8. Battery connection Green LED indicates connection to a battery
indicator
is correct.
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Operation
Some devices you can power up:
CAUTION: Read all operating instructions before operating the power pack.
The power pack is not intended for use as a UPS (Uninterruptible Power
Supply). The unit should be operated only in locations that meet the
following requirements:
• 13”TV
• Video Game System (20W)
• Weather Radio (10W)
(80W)
Dry
Don’t allow water or other liquids to drop or splash on the unit.
Operating AC appliances
1. Check battery status to ensure the battery is fully charged.
Cool
Ambient air temperature should be between -10° and 40° C
(14° and 104° F) – the cooler the better within this range.
Ventilated
Safe
Leave at least 2”(5 cm) clearance around the unit for air flow.
Ensure that the ventilation openings are not obstructed.
2. Open the AC Outlet cover.
3. Turn the AC socket switch ON.
Do not operate the unit in the same compartment as batteries
or in any compartment capable of storing flammable liquids
like gasoline.
4. Plug the AC appliance into AC outlets.
5. Turn the AC appliance ON.
Protect from Do not operate the unit where it will be exposed to battery
battery gases gases. These gases are very corrosive and prolonged exposure
will damage the power pack
6. Recharge the power pack immediately after use. See “recharging the
power pack battery”(page 12).
Low battery shut down
Unit will automatically shutdown when the battery reaches 10.0V DC. You must
turn off the AC power switch and charge the battery.
AC appliances
The power pack has one grounded AC power outlet for use with AC
appliance. You can either plug the appliance directly into the AC outlet or you
can use an AC power bar to increase the number of outlets available.
Overload and high temperature protection
In the event of an overload (>100W) or overheating, the power pack
automatically shuts down power to the AC outlets. If, after a while the audible
warning is ignored and a manual reset is not performed, the unit will do a
complete shutdown automatically.
However, for continuous operations, the combined loads must be less than
80W. The less wattage used, the longer the power pack will operate before
recharging is required.
Operating range:
• 80 watts or less for continuous operation
• 100 watts for 5-minute operation
Some appliance may be difficult or impossible to operate from the power
pack. They may have high surge requirements or may be incompatible with
the output waveform of the power pack. See “High Surge Appliances”and
“Trouble Appliances”(page 10).
NOTE: To determine required wattage for a device, look up required Amps a
device is rated. This Amperage is found on device I.D. tag in back of the unit.
Multiply Amps X Volts = Watts.
High surge appliances
The wattage rating of AC appliance is the average power used by the appliance.
Appliances such as televisions, computer monitors and appliances with motors
consume much more power than their average rating when they are first
switched on.
Although power pack can supply momentary surge power up to 400W, some
appliances may exceed the capabilities of the power pack and trigger the
inverter’s safety overload shutdown circuit.
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Operation
Problem appliances
USB Devices
The output of the power pack inverter is non-sinusoidal. Some equipment may
be damaged by the inverter’s modified sine wave output (non-sinusoidal).
Some appliance, including the types listed below, may be damaged if they are
connected to the inverter.
The power pack can charge or power one USB-chargeable device through its
USB port. Compatible devices include most MP3 players, PDAs, digital
cameras, and camcorders that have internal batteries which can be charged
via the USB port of a desktop/laptop computer.
•
Electronics that modulate RF (radio frequency) signals on the AC line will
not work and may be damaged.
USB-chargeable devices usually include a special USB cable (not supplied)
that attaches one end to the USB port and the other end to the device.
•
Speed controllers found in some fans, power tools, kitchen appliance, and
other loads may be damaged.
Using the Air Compressor
Warning: Fire Hazard
The compressor is designed for short-term operation only. Operating the
compressor over an extended period of time will cause the compressor unit
to overheat, which could lead to fire. Allow the compressor to cool down for
10 minutes after each 10 minutes of continuous operations.
•
•
Some chargers for small rechargeable batteries can be damaged.
Metal halide arc (MHI) lights can be damaged.
Note: If you are unsure about powering any device with the power pack,
contact the manufacturer of the device to determine whether it is compatible
with the modified sine wave output.
Warning: Fire Hazard
Do not leave the compressor unattended while in operation. Keep out of
reach of children.
12V DC appliances
Warning: Risk of personal injury or damage of equipment
The power pack can operate one 12V DC auto, RV, marine, or other portable DC
appliance that draws 10 amps or less from its DC socket. The combined load
must not exceed 120 W, The less combined wattage used, the longer the power
pack will operate before recharging is required.
Do not exceed the recommended pressure of either the compressor or the
object being inflated. The compressor is capable of inflating to 260 PSI.
If the recommended pressure is exceeded, an explosion may result.
Warning: Risk of personal injury or damage of equipment
Operating DC appliances:
If the power pack with air compressor shuts off due to an over-temperature
condition, turn OFF the compressor switch and allow the compressor to cool
for 15 minutes before re-starting. If the power switch is not turned off, the
compressor will automatically turn itself on when it reaches an acceptable
operating temperature. If left unattended, it is possible that the unit can over-
inflate the object being inflated and create an explosion hazard.
1. Check battery status to ensure the battery is fully charged.
2. Open the DC socket.
3. Plug the DC appliance into the DC socket.
4. Turn the DC appliance ON.
Caution: Equipment damage
5. Recharge the power pack immediately after use.
The power pack with air compressor cannot be used to inflate large capacity
inflatables such as float tubes, large air mattresses, transport truck tires, and
inflatable boats. These types of products require extended inflating times,
which may damage the compressor.
Download from Www.Somanuals.com. All Manual1s1Search And Download.
10
Operation
Inflating tires
Operation
Inflating small sports equipment
Caution:
You can use the compressor to inflate small sports equipment such as balls
If the pressure gauge on the compressor indicates more than twice the
recommended pressure for the object you are inflating and you have only
started to inflate the object, the valve connector is incorrectly connected to
the valve stem. This may damage the power pack with air compressor.
Remove and reattach the valve connector to the valve stem.
(soccer balls and footballs.)
Caution:
The unit cannot be used to inflate large capacity inflatables such as float
tubes, large air mattresses, transport truck tires, and inflatable boats. These
types of products require extended inflating times, which may damage the
compressor.
To inflate your vehicle, motorcycle, or bicycle tires:
1. Locate valve connector.
To inflate small sports equipment:
1. Choose the appropriate nozzle adapter.
2. Remove from storage and uncoil hose.
3. Remove valve stem cap from tire to be inflated.
4. Put the thumb latch in the OPEN position.
2. If an adapter is required, insert the nozzle adapter into the valve
connector, turning it clockwise to tighten, and close the thumb latch.
3. Place the valve connector fully on the valve stem or into the valve
receptacle on the item to be inflated.
5. Insert the desired adapter into the valve connector.
6. Place valve connector firmly and completely over valve stem on the tire.
4. Turn the compressor ON and inflate to appropriate pressure.
7. Press the thumb latch toward the house until it locks into the
closed position.
5. Turn the compressor OFF before removing valve connector from the
valve stem.
8. Insert into the valve receptacle on the item to be inflated.
9. Press the compressor switch to turn the compressor ON.
10. Inflate to desired pressure.
6. Remove nozzle adapter from the valve connector and store in storage
compartment of Accessory Bag.
Caution:
Allow the compressor to cool down for 10 minutes after each 10 minutes of
11. Press the compressor switch to turn the compressor OFF.
12. Remove the valve connector from the valve receptacle.
13. Put the thumb latch in the OPEN position.
14. Remove the adapter.
continuous operation. Repeat if necessary.
Note: Leave the thumb latch in the open position for storing to relieve
pressure on the internal mechanism.
15. Double-check the air pressure with a pressure gauge.
16. Replace valve stem cap.
17. Store the valve connector.
13
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Operation
To jump start a vehicle continued:
7. Switch off the jump start power switch.
8. Remove the red positive (+) clamp and then the black negative (-) clamp.
Jump starting a vehicle’s engine
You can use the power pack to jump start a vehicle (or boat engine) that has
a 12V starting battery using the jump start cables supplied with the unit.
WARNING: Fire Hazard
Recharging the power pack battery
A reverse polarity connection may cause damage to the unit and/or create a
sparking/explosion hazard. Never allow cables’red and black clamps to touch
each other or another common metal conductor. The connection of the
cables to the vehicle’s battery terminals must be positive to positive (red
clamp to battery“+”) and negative to negative (black clamp to battery“-“ or
vehicle chassis).
CAUTION: Do not operate AC or DC appliance while the power pack is
being charged.
Charging with the AC charging adapter
Using the AC charging adapter is the simplest method for recharging the
battery. While charging from an AC source, the charging status LED indicator
will light red. When the battery has reached capacity, the indicator will light
orange. Charging when the battery is fully discharged takes around 23 hours.
NOTE: Carefully follow these instructions for jump starting your vehicle as
they may be different from the instructions supplied with other jump start
products or cables.
NOTE: Recharge the 100W mobile power pack as soon as possible after each
use. When not used the power pack, it should be recharged every 3 months!
To jump start a vehicle:
1. Turn off the vehicle and all accessories.
To recharge with AC charger:
1. Turn the rotary switch to the “OFF”position.
2. Place the unit on a flat and stable surface near the battery which need to be
started. Ensure that the unit’s jump start power switch is“OFF”.
3. Connect the red positive (+) clamp of the cables to the positive (+)
terminal of the engine battery.
4. Connect the black negative (-) clamp of the cables to the engine block,
cylinder head, or other stationary heavy metal part of the motor. If the red
“Reverse Polarity”LED illuminates, then reverse polarity has been detected.
Correct polarity must be established before proceeding. Disconnect the
jump starting clamps from the vehicle’s battery and repeat steps (3) and (4).
5. Switch on the jump start power switch. Before starting the engine, make
sure the jumpstarter pack and the cables are clear of the metal parts and
other moving things.
2. Plug AC charging adapter into charging jack on the front of the unit.
3. Plug AC charging adapter into 120V AC electrical outlet.
4. Continually charge until the battery is fully charged; for about 23 hours.
CAUTION: The 23-hour charging time for the unit assumes that there is 120V
at the AC wall outlet. If the voltage is less than 120V AC, it may take more
than 23 hours to fully recharging. Once fully charged, the charging current
automatically reduces to a floating charge mode, and the unit may be left
permanently connected to the AC charger.
6. Crank the engine for 5 seconds or until it starts, whichever is first.
WARNING: Fire hazard
Do not try to start the engine for more than 5 seconds. The jump start
feature is designed for short term operation only. Operating the jump
starting feature for more than 5 seconds may cause damage to the unit.
Allow the unit to cool down for at least 3 minutes after each start attempt.
14
Download from Www.Somanuals.com. All Manual1s 5Search And Download.
Troubleshooting
Solution
Troubleshooting
Problem
Cause
Buzzing in audio systems and radios
Some inexpensive stereo systems and AM-FM radios have inadequate internal
power supply filtering and “buzz”slightly when powered by the power pack.
Generally, the only solution is an audio product with a higher quality filter.
The power pack can not jump The battery in the power pack Charge it for at 23 hours
start vehicle
is not fully charged
The engine start capacity
exceeds the power pack jump
start capacity.
Television interference
The power pack is shielded to minimize its interference with TV signals.
However, with weak TV signals interference may be visible in the form of lines
scrolling across the screen. The following should minimize or eliminate the
problem:
The power pack’s battery has Replace the power pack’s
been damaged
battery (consult service
technician).
The charging status LED
indicator does not light.
No AC power at the AC wall
outlet.
Ensure power is available at the
AC wall outlet.
•
•
•
Increase the distance between the inverter and the TV, antenna and cables.
Adjust the orientation of the inverter television, antenna and cables.
Maximize TV signal strength by using a better antenna and use shielded
antenna cable where possible.
AC charging adapter is faulty. Replace 120V AC charger
The AC charger’s output is too Replace the AC charger
The charging status LED
indicator still lights red and has low.
not charged to steady after 50
hours of charging.
WARNING: Electric shock hazard
The AC appliance does not
operate; audible alarm is not
sounding.
AC appliance rated more than Use AC appliance with a power
Do not remove the cover of the unit or disassemble. The unit does not contain
any internal user-serviceable parts and attempting to service the unit yourself
could result in electrical shock or burn.
80W, the safety overload has rating less than 80W.
tripped.
AC appliance rated less than AC appliance may exceed the
80W, high starting surge has power pack’s surge capability.
tripped the safety overload.
Use an AC appliance with a
starting surge within the power
pack surge rating.
Battery has discharged to 10V Recharge the battery.
Inverter has overheated due to Allow the power pack to cool for
poor ventilation or excessively 15 minutes or more. Clear
warm environmental condition. blocked fan opening or remove
objects covering the unit, then
restart the power pack. Move to
a cooler environment.
Run time for appliance is less Internal battery is not fully
Recharge using the AC charger,
until the charging status LED
indicator light green.
than expected.
charged,
AC appliance power
consumption is higher than
expected.
Check AC appliance power or
wattage rating (or current draw
for 12V DC appliance).
17
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
12 DC Power:
Internal battery (Capacity/Type)
DC power socket (maximum continuous load) 8A with automatic reset
Product Service
For any questions about operating this new Cobra product, or if parts are
missing…PLEASE CALL COBRA FIRST…do not return this product to the store.
See customer assistance on page A3.
7Ah/12V sealed lead-acid battery
DC fuse
15A
If your product should require factory service, please call Cobra first before
sending your unit. This will ensure the fastest turn-around time on your repair.
You may be asked to send your jumpstarter/power pack to the Cobra factory.
AC Power:
Output power
• Continuous AC output power
• Five minute AC output power
• AC output surge capacity
80W
100W
400W
It will be necessary to furnish the following to have the product serviced and
returned.
1. For warranty repair include some form of proof-of-purchase, such as a
mechanical reproduction or carbon copy of a sales receipt. If you send the
original receipt, it cannot be returned.
Output voltage
Output frequency
104V-125V
58Hz-62Hz
Output wave form
No load current draw
Input voltage range
Low battery shutdown
Low battery shutdown resume
High battery voltage shutdown
Over temperature shutdown
Overload shutdown
Modified sine wave
<0.5A
2. Send the entire product.
3. Enclose a description of what is happening with the jump starter/power
pack. Include a typed or clearly printed name and address of where the unit
is to be returned.
10.5V-15.5VDC
10.0 0.3VDC
12.0 0.3VDC
15.5V 0.3VDC
Yes
4. Pack unit securely to prevent damage in transit. If possible, use the original
packing material.
5. Ship prepaid and insured by way of a traceable carrier such as United Parcel
Service (UPS) or Priority Mail to avoid loss in transit to:
Yes
Operating temperature range
Storage temperature range
14°F~104°F (-10°C~40°C)
-4°F~158°F (-20°C~70°C)
Cobra Factory Service
Cobra Electronics Corporation
6500 West Cortland Street
Chicago, Illinois 60707 USA.
Internal battery charging controller system:
AC charging bulk charging current
Peak charging voltage (nominal)
300mA
14.2V 0.2V
12.9V 0.2V
6. If the jumpstarter/power pack is in warranty, upon receipt of your unit, it
will either be repaired or exchanged depending on the model. Please allow
approximately three to four weeks before contacting Cobra for status. If the
unit is out of warranty, a letter will automatically be sent informing you of
the repair charge or replacement charge.
Charging restart voltage (nominal)
Air compressor:
Inflation pressure
260 PSI
Physical Specifications:
Jumpstarter cables (size/length)
Dimensions H*W*D
If you have any questions, please call 773-889-3087 for assistance.
8.37mm2/(460 19.5)mm
13.25” H x 12” W x 5.5” D
(330.2mm x 309mm x 114.3mm)
10 lbs., 5.6 oz. (4.7g)
Weight
18
Download from Www.Somanuals.com. All Manual1s 9Search And Download.
|