Regulatory Compliance and Safety Information
for the Cisco AS5400 and Cisco AS5400XM
Universal Gateways
Read this document before installing or servicing the following systems:
•
•
Cisco AS5400 universal gateway
Cisco AS5400XM universal gateway
Note
Only trained and qualified service personnel (as defined in IEC 60950 and AS/NZS 3260) should install,
replace, or service the equipment. Install the system in accordance with the U.S. National Electric Code
if you are in the United States.
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this device.
Statement 1071
SAVE THESE INSTRUCTIONS
This document contains the following sections:
•
•
•
•
•
•
Corporate Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Copyright © 2004 Cisco Systems, Inc. All rights reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintaining Safe Installation Distances
Maintaining Safe Installation Distances
Except at the edge connector that plugs into the host chassis expansion slot, clearance and creepage
distances of x millimeters (mm) and y mm as listed in Table 1 must be maintained between the cards and
other parts of the host, including any other expansion cards fitted.
Table 1
Creepage and Clearance Distances Based on Voltage
Voltage Used or Generated by Other Parts of the
Host or Expansion Card (Vrms1 or VDC2)
Creepage
(y mm)3
Clearance
(x mm)
Up to 50
2.4 (3.8)
3.0 (4.8)
5.0 (8.0)
6.4 (10.0)
2.0
2.6
4.0
4.0
Up to 125
Up to 250
Up to 300
1. Vrms = root mean square voltage.
2. VDC = volts direct current
3. The creepage distances not in parentheses apply when the equipment is installed in a normal office
environment. The larger dimensions, in parentheses, must be applied when the equipment is installed in an
environment in which dust and other types of pollution could conduct electricity because of the effects of
dampness and condensation. This applies to locations subject to high humidity.
Clearance distances are defined as the minimum distance measured in air between two points (that
is, line of sight).
Creepage distances are defined as the minimum distance measured across the surface of an insulator
between two points (that is, following the contour of the insulator).
Figure 1
Creepage and Clearance Distances between BRI WAN Interface Card and Components
Host
y
Card
Adjacent card
x
x
Component
components, and “y” shows the creepage path across the surface of an insulator and between the two
points indicated by “x.”
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Translated Safety Warnings
This section includes translations in multiple languages of the warnings that may appear in your product
documents.
Statement 1—Power Disconnection Warning
Warning
Before working on a system that has an on/off switch, turn OFF the power and unplug the power cord.
Waarschuwing
Voordat u aan een systeem werkt dat een aan/uit schakelaar heeft, dient u de stroomvoorziening UIT
te schakelen en de stekker van het netsnoer uit het stopcontact te halen.
Varoitus
Attention
Warnung
Ennen kuin teet mitään sellaiselle järjestelmälle, jossa on kaksiasentokytkin, katkaise siitä virta ja
kytke virtajohto irti.
Avant de travailler sur un système équipé d'un commutateur marche-arrêt, mettre l'appareil à l'arrêt
(OFF) et débrancher le cordon d'alimentation.
Bevor Sie an einem System mit Ein/Aus-Schalter arbeiten, schalten Sie das System AUS und ziehen
das Netzkabel aus der Steckdose.
Avvertenza
Advarsel
Prima di lavorare su un sistema dotato di un interruttore on/off, spegnere (OFF) il sistema e staccare
il cavo dell’alimentazione.
Slå AV strømmen og trekk ut strømledningen før det utføres arbeid på et system som er utstyrt med
en av/på-bryter.
Aviso
Antes de começar a trabalhar num sistema que tem um interruptor on/off, DESLIGUE a corrente
eléctrica e retire o cabo de alimentação da tomada.
¡Advertencia!
Varning!
Antes de utilizar cualquier sistema equipado con interruptor de Encendido/Apagado (ON/OFF),
cortar la alimentación y desenchufar el cable de alimentación.
Slå AV strömmen och dra ur nätsladden innan du utför arbete på ett system med strömbrytare.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 2—Disconnecting Telephone-Network Cables
Warning
Waarschuwing
Varoitus
Before opening the chassis, disconnect the telephone-network cables to avoid contact with
telephone-network voltages.
Voordat u het frame opent, dient u de verbinding met het telefoonnetwerk te verbreken door de
kabels te ontkoppelen om zo contact met telefoonnetwerk-spanningen te vermijden.
Vältä joutumista kosketuksiin puhelinverkostojännitteiden kanssa irrottamalla puhelinverkoston
kaapelit ennen asennuspohjan aukaisemista.
Attention
Avant d'ouvrir le châssis, débrancher les câbles du réseau téléphonique afin d'éviter tout contact
avec les tensions d'alimentation du réseau téléphonique.
Warnung
Bevor Sie das Chassis öffnen, ziehen Sie die Telefonnetzkabel aus der Verbindung, um Kontakt mit
Telefonnetzspannungen zu vermeiden.
Avvertenza
Advarsel
Prima di aprire il telaio, scollegare i cavi della rete telefonica per evitare di entrare in contatto con
la tensione di rete.
Før kabinettet åpnes, skal kablene for telenettet kobles fra for å unngå å komme i kontakt med
spenningen i telenettet.
Aviso
Antes de abrir o chassis, desligue os cabos da rede telefónica para evitar contacto com a tensão da
respectiva rede.
¡Advertencia!
Varning!
Antes de abrir el chasis, desconectar el cableado dirigido a la red telefónica para evitar contacto
con voltajes de la propia red.
Koppla loss ledningarna till telefonnätet innan du öppnar chassit så att kontakten med
telefonnätsspänningen bryts.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 4—Power Supply Warning
Warning
Do not touch the power supply when the power cord is connected. For systems with a power switch,
line voltages are present within the power supply even when the power switch is off and the power
cord is connected. For systems without a power switch, line voltages are present within the power
supply when the power cord is connected.
Waarschuwing
U dient de voeding niet aan te raken zolang het netsnoer aangesloten is. Bij systemen met een
stroomschakelaar zijn er lijnspanningen aanwezig in de voeding, zelfs wanneer de
stroomschakelaar uitgeschakeld is en het netsnoer aangesloten is. Bij systemen zonder een
stroomschakelaar zijn er lijnspanningen aanwezig in de voeding wanneer het netsnoer aangesloten
is.
Varoitus
Älä kosketa virtalähdettä virtajohdon ollessa kytkettynä. Virrankatkaisimella varustetuissa
järjestelmissä on virtalähteen sisällä jäljellä verkkojännite, vaikka virrankatkaisin on
katkaistu-asennossa virtajohdon ollessa kytkettynä. Järjestelmissä, joissa ei ole virrankatkaisinta,
on virtalähteen sisällä verkkojännite, kun virtajohto on kytkettynä.
Attention
Ne pas toucher le bloc d'alimentation quand le cordon d'alimentation est branché. Avec les
systèmes munis d'un commutateur marche-arrêt, des tensions de ligne sont présentes dans
l'alimentation quand le cordon est branché, même si le commutateur est à l'arrêt. Avec les systèmes
sans commutateur marche-arrêt, l'alimentation est sous tension quand le cordon d'alimentation est
branché.
Warnung
Berühren Sie das Netzgerät nicht, wenn das Netzkabel angeschlossen ist. Bei Systemen mit
Netzschalter liegen Leitungsspannungen im Netzgerät vor, wenn das Netzkabel angeschlossen ist,
auch wenn das System ausgeschaltet ist. Bei Systemen ohne Netzschalter liegen
Leitungsspannungen im Netzgerät vor, wenn das Netzkabel angeschlossen ist.
Avvertenza
Non toccare l’alimentatore se il cavo dell’alimentazione è collegato. Per i sistemi con un
interruttore di alimentazione, tensioni di linea sono presenti all’interno dell’alimentatore anche
quando l’interruttore di alimentazione è en posizione di disattivazione (off), se il cavo
dell’alimentazione è collegato. Per i sistemi senza un interruttore, tensioni di linea sono presenti
all’interno dell’alimentatore quando il cavo di alimentazione è collegato.
Advarsel
Berør ikke strømforsyningsenheten når strømledningen er tilkoblet. I systemer som har en
strømbryter, er det spenning i strømforsyningsenheten selv om strømbryteren er slått av og
strømledningen er tilkoblet. Når det gjelder systemer uten en strømbryter, er det spenning i
strømforsyningsenheten når strømledingen er tilkoblet.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Aviso
Não toque na unidade abastecedora de energia quando o cabo de alimentação estiver ligado. Em
sistemas com interruptor, a corrente eléctrica estará presente na unidade abastecedora, sempre
que o cabo de alimentação de energia estiver ligado, mesmo quando o interruptor se encontrar
desligado. Para sistemas sem interruptor, a tensão eléctrica dentro da unidade abastecedora só
estará presente quando o cabo de alimentação estiver ligado.
¡Advertencia!
Varning!
No tocar la fuente de alimentación mientras el cable esté enchufado. En sistemas con interruptor de
alimentación, hay voltajes de línea dentro de la fuente, incluso cuando el interruptor esté en
Apagado (OFF) y el cable de alimentación enchufado. En sistemas sin interruptor de alimentación,
hay voltajes de línea en la fuente cuando el cable está enchufado.
Vidrör inte strömförsörjningsenheten när nätsladden är ansluten. För system med strömbrytare finns
det nätspänning i strömförsörjningsenheten även när strömmen har slagits av men nätsladden är
ansluten. För system utan strömbrytare finns det nätspänning i strömförsörjningsenheten när
nätsladden är ansluten.
Statement 8—DC Power Connection Warning
Warning
After wiring the DC power supply, remove the tape from the circuit breaker switch handle and
reinstate power by moving the handle of the circuit breaker to the ON position.
Waarschuwing
Nadat de bedrading van de gelijkstroom voeding aangebracht is, verwijdert u het plakband van de
schakelaarhendel van de stroomverbreker en schakelt de stroom weer in door de hendel van de
stroomverbreker naar de AAN positie te draaien.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Varoitus
Attention
Warnung
Yhdistettyäsi tasavirtalähteen johdon avulla poista teippi suojakytkimen varresta ja kytke virta
uudestaan kääntämällä suojakytkimen varsi KYTKETTY-asentoon.
Une fois l'alimentation connectée, retirer le ruban adhésif servant à bloquer la poignée du
disjoncteur et rétablir l'alimentation en plaçant cette poignée en position de marche (ON).
Nach Verdrahtung des Gleichstrom-Netzgeräts entfernen Sie das Klebeband vom Schaltergriff des
Unterbrechers und schalten den Strom erneut ein, indem Sie den Griff des Unterbrechers auf EIN
stellen.
Avvertenza
Advarsel
Dopo aver eseguito il cablaggio dell’alimentatore CC, togliere il nastro adesivo dall’interruttore
automatico e ristabilire l’alimentazione spostando all'interruttore automatico in posizione ON.
Etter at likestrømsenheten er tilkoblet, fjernes teipen fra håndtaket på strømbryteren, og deretter
aktiveres strømmen ved å dreie håndtaket på strømbryteren til PÅ-stilling.
Aviso
Depois de ligar o sistema de fornecimento de corrente contínua, retire a fita isoladora da manivela
do disjuntor, e volte a ligar a corrente ao deslocar a manivela para a posição ON (Ligado).
¡Advertencia!
Después de cablear la fuente de alimentación de corriente continua, retirar la cinta de la palanca
del interruptor automático, y restablecer la alimentación cambiando la palanca a la posición de
Encendido (ON).
Varning!
När du har kopplat ledningarna till strömförsörjningsenheten för inmatad likström tar du bort tejpen
från överspänningsskyddets omkopplare och slår på strömmen igen genom att ställa
överspänningsskyddets omkopplare i TILL-läget.
Statement 12—Power Supply Disconnection Warning
Warning
Before working on a chassis or working near power supplies, unplug the power cord on AC units;
disconnect the power at the circuit breaker on DC units.
Waarschuwing
Voordat u aan een frame of in de nabijheid van voedingen werkt, dient u bij wisselstroom toestellen
de stekker van het netsnoer uit het stopcontact te halen; voor gelijkstroom toestellen dient u de
stroom uit te schakelen bij de stroomverbreker.
Varoitus
Kytke irti vaihtovirtalaitteiden virtajohto ja katkaise tasavirtalaitteiden virta suojakytkimellä, ennen
kuin teet mitään asennuspohjalle tai työskentelet virtalähteiden läheisyydessä.
Attention
Avant de travailler sur un châssis ou à proximité d'une alimentation électrique, débrancher le
cordon d'alimentation des unités en courant alternatif ; couper l'alimentation des unités en courant
continu au niveau du disjoncteur.
Warnung
Bevor Sie an einem Chassis oder in der Nähe von Netzgeräten arbeiten, ziehen Sie bei
Wechselstromeinheiten das Netzkabel ab bzw. schalten Sie bei Gleichstromeinheiten den Strom am
Unterbrecher ab.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Avvertenza
Advarsel
Prima di lavorare su un telaio o intorno ad alimentatori, scollegare il cavo di alimentazione sulle
unità CA; scollegare l'alimentazione all’interruttore automatico sulle unità CC.
Før det utføres arbeid på kabinettet eller det arbeides i nærheten av strømforsyningsenheter, skal
strømledningen trekkes ut på vekselstrømsenheter og strømmen kobles fra ved strømbryteren på
likestrømsenheter.
Aviso
¡Advertencia!
Varning!
Antes de trabalhar num chassis, ou antes de trabalhar perto de unidades de fornecimento de
energia, desligue o cabo de alimentação nas unidades de corrente alternada; desligue a corrente
no disjuntor nas unidades de corrente contínua.
Antes de manipular el chasis de un equipo o trabajar cerca de una fuente de alimentación,
desenchufar el cable de alimentación en los equipos de corriente alterna (CA); cortar la
alimentación desde el interruptor automático en los equipos de corriente continua (CC).
I
nnan du arbetar med ett chassi eller nära strömförsörjningsenheter skall du för växelströmsenheter
dra ur nätsladden och för likströmsenheter bryta strömmen vid överspänningsskyddet.
Statement 13—Circuit Breaker (15A) Warning
Warning
This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure
that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on
the phase conductors (all current-carrying conductors).
Waarschuwing
Dit produkt is afhankelijk van de installatie van het gebouw voor kortsluit- (overstroom) beveiliging.
Controleer of er een zekering of stroomverbreker van niet meer dan 120 Volt wisselstroom, 15 A voor
de V.S. (240 Volt wisselstroom, 10 A internationaal) gebruikt wordt op de fasegeleiders (alle
geleiders die stroom voeren).
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Varoitus
Attention
Warnung
Tämä tuote on riippuvainen rakennukseen asennetusta oikosulkusuojauksesta
(ylivirtasuojauksesta). Varmista, että vaihevirtajohtimissa (kaikissa virroitetuissa johtimissa)
käytetään Yhdysvalloissa alle 120 voltin, 15 ampeerin ja monissa muissa maissa 240 voltin,
10 ampeerin sulaketta tai suojakytkintä.
Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit dépend de
l'installation électrique du local. Vérifier qu'un fusible ou qu'un disjoncteur de 120 V alt., 15 A U.S.
maximum (240 V alt., 10 A international) est utilisé sur les conducteurs de phase (conducteurs de
charge).
Dieses Produkt ist darauf angewiesen, daß im Gebäude ein Kurzschluß- bzw. Überstromschutz
installiert ist. Stellen Sie sicher, daß eine Sicherung oder ein Unterbrecher von nicht mehr als 240 V
Wechselstrom, 10 A (bzw. in den USA 120 V Wechselstrom, 15 A) an den Phasenleitern (allen
stromführenden Leitern) verwendet wird.
Avvertenza
Questo prodotto dipende dall’installazione dell’edificio per quanto riguarda la protezione contro
cortocircuiti (sovracorrente). Verificare che un fusibile o interruttore automatico, non superiore a
120 VCA, 15 A U.S. (240 VCA, 10 A internazionale) sia stato usato nei fili di fase (tutti i conduttori
portatori di corrente).
Advarsel
Aviso
Dette produktet er avhengig av bygningens installasjoner av kortslutningsbeskyttelse (overstrøm).
Kontroller at det brukes en sikring eller strømbryter som ikke er større enn 120 VAC, 15 A (USA)
(240 VAC, 10 A internasjonalt) på faselederne (alle strømførende ledere).
Este produto depende das instalações existentes para protecção contra curto-circuito (sobrecarga).
Assegure-se de que um fusível ou disjuntor não superior a 240 VAC, 10A é utilizado nos condutores
de fase (todos os condutores de transporte de corrente).
¡Advertencia!
Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) deló propio
edificio. Asegurarse de que se utiliza un fusible o interruptor automático de no más de 240 voltios
en corriente alterna (VAC), 10 amperios del estándar internacional (120 VAC, 15 amperios del
estándar USA) en los hilos de fase (todos aquéllos portadores de corriente).
Varning!
Denna produkt är beroende av i byggnaden installerat kortslutningsskydd (överströmsskydd).
Kontrollera att säkring eller överspänningsskydd används på fasledarna (samtliga strömförande
ledare) för internationellt bruk max. 240 V växelström, 10 A (i USA max. 120 V växelström, 15 A).
Statement 14—Power Cord Warning
Warning
This unit might have more than one power cord. To reduce the risk of electric shock, disconnect the
two power supply cords before servicing the unit.
Waarschuwing
Dit toestel kan meer dan één netsnoer hebben. Om het risico van een elektrische schok te
verminderen, dient u de stekkers van de twee netsnoeren uit het stopcontact te halen voordat u het
toestel een servicebeurt geeft.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Varoitus
Attention
Warnung
Tässä laitteessa saattaa olla useampi kuin yksi virtajohto. Irrota molemmat virtalähteestä tulevat
johtimet ennen laitteen huoltamista, jotta vältät sähköiskun vaaran.
Il est possible que cette unité soit munie de plusieurs cordons d'alimentation. Pour éviter les risques
d'électrocution, débrancher les deux cordons d'alimentation avant de réparer l'unité.
Diese Einheit hat möglicherweise mehr als ein Netzkabel. Zur Verringerung der Stromschlaggefahr
trennen Sie beide Netzgerätekabel ab, bevor Sie die Einheit warten.
Avvertenza
Questa unità potrebbe essere dotata di più di un cavo di alimentazione. Per ridurre il rischio di
scossa elettrica, scollegare i due cavi di alimentazione prima di procedere alla manutenzione
dell’unità.
Advarsel
Aviso
Denne enheten kan være utstyrt med mer enn én strømledning. Koble fra de to strømledningene før
det utføres reparasjonsarbeid på enheten for å redusere faren for elektriske støt.
Esta unidade poderá ter mais do que um cabo de alimentação. Para reduzir o risco de choque
eléctrico, desligue os dois cabos de alimentação antes de efectuar reparações na unidade.
¡Advertencia!
Varning!
Puede ser que este equipo posea más de un cable de alimentación. Para reducir el riesgo de
descarga eléctrica, desenchufar los dos cables antes de proceder al mantenimiento de la unidad.
Denna enhet kan vara försedd med mer än en nätsladd. För att minska risken för elektriska stötar
skall båda nätsladdarna dras ur innan du utför underhållsarbete på enheten.
Statement 19—TN Power Warning
Warning
The device is designed to work with TN power systems.
Waarschuwing
Varoitus
Het apparaat is ontworpen om te functioneren met TN energiesystemen.
Koje on suunniteltu toimimaan TN-sähkövoimajärjestelmien yhteydessä.
Ce dispositif a été conçu pour fonctionner avec des systèmes d'alimentation TN.
Attention
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Warnung
Avvertenza
Advarsel
Das Gerät ist für die Verwendung mit TN-Stromsystemen ausgelegt.
Il dispositivo è stato progettato per l’uso con sistemi di alimentazione TN.
Utstyret er utfomet til bruk med TN-strømsystemer.
Aviso
O dispositivo foi criado para operar com sistemas de corrente TN.
El equipo está diseñado para trabajar con sistemas de alimentación tipo TN.
Enheten är konstruerad för användning tillsammans med elkraftssystem av TN-typ.
¡Advertencia!
Varning!
Statement 23—ISDN Connection Warning
Warning
The ISDN connection is regarded as a source of voltage that should be inaccessible to user contact.
Do not attempt to tamper with or open any public telephone operator (PTO)-provided equipment or
connection hardware. Any hardwired connection (other than by a nonremovable,
connect-one-time-only plug) must be made only by PTO staff or suitably trained engineers.
Waarschuwing
De verbinding met ISDN (Integrated Services Digital Network = Digitaal netwerk met geïntegreerde
faciliteiten) wordt beschouwd als een spanningsbron die ontoegankelijk dient te zijn voor
gebruikers. Gebruikers dienen geen poging te doen om door de openbare telefoondienst (PTT)
verstrekte apparatuur of aansluitingshardware te openen of ermee te knoeien. Alle vastbedrade
verbindingen (behalve die verbindingen die gemaakt zijn door een niet-verwijderbare, slechts
eenmaal te verbinden stekker) dienen slechts door PTT-personeel of door daartoe opgeleide
ingenieurs gemaakt te worden.
Varoitus
ISDN-liitäntää pidetään jännitelähteenä, jonka kanssa käyttäjän ei tulisi päästä kosketuksiin.
Käyttäjien ei tulisi yrittää peukaloida tai avata laitteita tai liittimiä, jotka kuuluvat yleiselle
puhelinlaitokselle (PTO). Ainoastaan yleisen puhelinlaitoksen henkilökunnan tai ammattitaitoisten
teknikoiden tulee tehdä kaapeliliitännät (lukuun ottamatta kiinteitä pistokkeita, jotka yhdistetään
ainoastaan yhden kerran).
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Attention
Warnung
La connexion du réseau numérique intégré (Integrated Services Digital Network ou ISDN) constitue
une source de tension qui ne doit pas être accessible à l'utilisateur. Les utilisateurs ne doivent
jamais tenter de modifier ni même d'ouvrir un matériel fourni par une compagnie de téléphone
public, ou le matériel de connexion. Toute connexion câblée (autre que celles établies par une prise
non démontable à connexion unique) ne doit être effectuée que par le personnel de la compagnie de
téléphone ou par des techniciens proprement formés.
Die ISDN-Verbindung gilt als eine Spannungsquelle, die dem Anwender unzugänglich sein sollte.
Anwender sollten nicht versuchen, sich an der von den Anbietern öffentlicher TK-Dienste
gelieferten Ausstattung oder Verbindungs-Hardware zu schaffen zu machen oder sie zu öffnen. Alle
festverdrahteten Verbindungen (mit Ausnahme der Verbindungen mit einem nicht abnehmbaren, nur
einmal anzuschließenden Stecker) sind von Mitarbeitern des TK-Anbieters oder von entsprechend
geschulten Technikern herzustellen.
Avvertenza
Il collegamento ISDN (Integrated Services Digital Network - Rete digitale a servizi integrati) viene
considerato come una fonte di tensione che dovrebbe essere inaccessibile al contatto dell’utente.
Gli utenti non devono né manomettere né provare ad aprire le apparecchiature o i dispositivi di
collegamento forniti dalla società telefonica. Qualsiasi collegamento cablato (ad eccezione di una
spina non rimovibile, da installare una sola volta) deve essere eseguito esclusivamente da un
dipendente della società telefonica o da tecnici specializzati.
Advarsel
Aviso
ISDN-koblingen betraktes som en spenningskilde som bør være utilgjengelig for brukeren. Brukere
bør ikke klusse med eller åpne utstyr eller tilkoblingsmateriale som er utstyrt av Telenor. Eventuelle
faste installasjoner (bortsett fra koblinger som er foretatt med et støpsel for engangsbruk og som
ikke kan fjernes) må kun utføres av Telenor-montører.
A conexão RDIS (Rede Digital com Integração de Serviços) é interpretada como uma fonte de tensão
que deverá ser inacessível ao utilizador. Os utilizadores não deverão tentar violar qualquer
equipamento ou conexão de serviço telefónico público. Qualquer conexão de rede de fios (para
além daquela estabelecida por uma ficha não-removível de ligação única), deverá apenas ser
efectuada por pessoal dos serviços telefónicos ou engenheiros devidamente treinados.
¡Advertencia!
La conexión al circuito RDSI (Red Digital de Servicios Integrados) se considera como una fuente de
voltaje con la cual el usuario no debe entrar en contacto. Los usuarios deberán evitar manipular
indebidamente, o abrir, los equipos o hardware de conexión proporcionados por cualquier
compañía operadora de la red pública de telefonía. Las conexiones de cable rígido que sean
necesarias (excepto las de clavija no desmontable de un solo uso) deberán ser realizadas
exclusivamente por personal de la entidad operadora de la red pública de telefonía, o por personal
técnico adecuadamente capacitado.
Varning!
ISDN-anslutningen betraktas som en spänningskälla och bör inte vara åtkomlig för användaren
(ISDN: Integrated Services Digital Network = digitalt flertjänstnät). Användare får inte manipulera
eller söka öppna utrustning eller anslutningsdon som tillhandahållits av telefonbolag
(PTO-produkter). Anslutning av ledningar (med undantag av en icke löstagbar propp för
engångsanslutning) får endast utföras av PTO-anställda eller lämpligt utbildade tekniker.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 39—Grounded Equipment Warning
Warning
Waarschuwing
Varoitus
This equipment is intended to be grounded. Ensure that the host is connected to earth ground during
normal use.
Deze apparatuur hoort geaard te worden Zorg dat de host-computer tijdens normaal gebruik met
aarde is verbonden.
Tämä laitteisto on tarkoitettu maadoitettavaksi. Varmista, että isäntälaite on yhdistetty maahan
normaalikäytön aikana.
Attention
Cet équipement doit être relié à la terre. S’assurer que l’appareil hôte est relié à la terre lors de
l’utilisation normale.
Warnung
Dieses Gerät muß geerdet werden. Stellen Sie sicher, daß das Host-Gerät während des normalen
Betriebs an Erde gelegt ist.
Avvertenza
Questa apparecchiatura deve essere collegata a massa. Accertarsi che il dispositivo host sia
collegato alla massa di terra durante il normale utilizzo.
Advarsel
Aviso
Dette utstyret skal jordes. Forviss deg om vertsterminalen er jordet ved normalt bruk.
Este equipamento deverá estar ligado à terra. Certifique-se que o host se encontra ligado à terra
durante a sua utilização normal.
¡Advertencia!
Varning!
Este equipo debe conectarse a tierra. Asegurarse de que el equipo principal esté conectado a tierra
durante el uso normal.
Denna utrustning är avsedd att jordas. Se till att värdenheten är jordad vid normal användning.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 43—Jewelry Removal Warning
Warning
Before working on equipment that is connected to power lines, remove jewelry (including rings,
necklaces, and watches). Metal objects will heat up when connected to power and ground and can
cause serious burns or weld the metal object to the terminals.
Waarschuwing
Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief
ringen, kettingen en horloges) verwijderen. Metalen voorwerpen worden warm wanneer ze met
stroom en aarde zijn verbonden, en kunnen ernstige brandwonden veroorzaken of het metalen
voorwerp aan de aansluitklemmen lassen.
Varoitus
Attention
Warnung
Avvertenza
Advarsel
Ennen kuin työskentelet voimavirtajohtoihin kytkettyjen laitteiden parissa, ota pois kaikki korut
(sormukset, kaulakorut ja kellot mukaan lukien). Metalliesineet kuumenevat, kun ne ovat
yhteydessä sähkövirran ja maan kanssa, ja ne voivat aiheuttaa vakavia palovammoja tai hitsata
metalliesineet kiinni liitäntänapoihin.
Avant d’accéder à cet équipement connecté aux lignes électriques, ôter tout bijou (anneaux,
colliers et montres compris). Lorsqu’ils sont branchés à l’alimentation et reliés à la terre, les objets
métalliques chauffent, ce qui peut provoquer des blessures graves ou souder l’objet métallique aux
bornes.
Vor der Arbeit an Geräten, die an das Netz angeschlossen sind, jeglichen Schmuck (einschließlich
Ringe, Ketten und Uhren) abnehmen. Metallgegenstände erhitzen sich, wenn sie an das Netz und die
Erde angeschlossen werden, und können schwere Verbrennungen verursachen oder an die
Anschlußklemmen angeschweißt werden.
Prima di intervenire su apparecchiature collegate alle linee di alimentazione, togliersi qualsiasi
monile (inclusi anelli, collane, braccialetti ed orologi). Gli oggetti metallici si riscaldano quando
sono collegati tra punti di alimentazione e massa: possono causare ustioni gravi oppure il metallo
può saldarsi ai terminali.
Fjern alle smykker (inkludert ringer, halskjeder og klokker) før du skal arbeide på utstyr som er
koblet til kraftledninger. Metallgjenstander som er koblet til kraftledninger og jord blir svært varme
og kan forårsake alvorlige brannskader eller smelte fast til polene.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Aviso
¡Advertencia!
Varning!
Antes de trabalhar em equipamento que esteja ligado a linhas de corrente, retire todas as jóias que
estiver a usar (incluindo anéis, fios e relógios). Os objectos metálicos aquecerão em contacto com
a corrente e em contacto com a ligação à terra, podendo causar queimaduras graves ou ficarem
soldados aos terminais.
Antes de operar sobre equipos conectados a líneas de alimentación, quitarse las joyas (incluidos
anillos, collares y relojes). Los objetos de metal se calientan cuando se conectan a la alimentación
y a tierra, lo que puede ocasionar quemaduras graves o que los objetos metálicos queden soldados
a los bornes.
Tag av alla smycken (inklusive ringar, halsband och armbandsur) innan du arbetar på utrustning som
är kopplad till kraftledningar. Metallobjekt hettas upp när de kopplas ihop med ström och jord och
kan förorsaka allvarliga brännskador; metallobjekt kan också sammansvetsas med kontakterna.
Statement 49—Qualified Personnel Warning
Warning
Only trained and qualified personnel should be allowed to install or replace this equipment.
Waarschuwing
Varoitus
Installatie en reparaties mogen uitsluitend door getraind en bevoegd personeel uitgevoerd worden.
Ainoastaan koulutettu ja pätevä henkilökunta saa asentaa tai vaihtaa tämän laitteen.
Avertissement
Tout installation ou remplacement de l'appareil doit être réalisé par du personnel qualifié et
compétent.
Achtung
Gerät nur von geschultem, qualifiziertem Personal installieren oder auswechseln lassen.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Avvertenza
Solo personale addestrato e qualificato deve essere autorizzato ad installare o sostituire questo
apparecchio.
Advarsel
Aviso
Kun kvalifisert personell med riktig opplæring bør montere eller bytte ut dette utstyret.
Este equipamento deverá ser instalado ou substituído apenas por pessoal devidamente treinado e
qualificado.
¡Atención!
Varning
Estos equipos deben ser instalados y reemplazados exclusivamente por personal técnico
adecuadamente preparado y capacitado.
Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal.
Statement 61—Power Supply Wiring Warning
.
Warning
The illustration shows the DC power supply terminal block. Wire the DC power supply using the
appropriate wire terminations at the wiring end, as illustrated. The proper wiring sequence is
ground to ground, positive to positive (line to L), and negative to negative (neutral to N). Note that
the ground wire should always be connected first and disconnected last.
Waarschuwing
De figuur toont de aansluitstrip van de gelijkstroomvoeding. Breng de bedrading aan voor de
gelijkstroomvoeding met behulp van de juiste draadaansluitingen aan het draadeinde zoals
aangegeven. De juiste bedradingsvolgorde is aarde naar aarde, positief naar positief (lijn naar L) en
negatief naar negatief (neutraal naar N). Let op dat de aarddraad altijd het eerst verbonden en het
laatst losgemaakt wordt.
Varoitus
Kuva esittää tasavirran pääterasiaa. Liitä tasavirtalähde johdon avulla käyttäen sopivia
johdinliitäntöjä johdon päässä kuvan esittämällä tavalla. Oikea kytkentäjärjestys on maajohto
maajohtoon, positiivinen positiiviseen (johto L:ään) ja negatiivinen negatiiviseen (nollajohto N:ään).
Ota huomioon, että maajohto on aina yhdistettävä ensin ja irrotettava viimeisenä.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Attention
Warnung
La figure illustre le bloc de connexion de l'alimentation en courant continu. Câbler l'alimentation
en courant continu en fixant les extrémités de fil qui conviennent aux extrémités câblées
conformément au schéma. La séquence de câblage à suivre est terre-terre, positif-positif (ligne sur
L), et négatif-négatif (neutre sur N). Noter que le fil de masse doit toujours être connecté en premier
et déconnecté en dernier.
Die Abbildung zeigt den Terminalblock des Gleichstrom-Netzgeräts. Verdrahten Sie das
Gleichstrom-Netzgerät unter Verwendung von geeigneten Kabelschuhen am Verdrahtungsende
(siehe Abbildung). Die richtige Verdrahtungsfolge ist Erde an Erde, positiv an positiv (Leitung an L)
und negativ an negativ (neutral an N). Beachten Sie bitte, daß der Erdungsdraht immer als erster
verbunden und als letzter abgetrennt werden sollte.
Avvertenza
Advarsel
Aviso
L’illustrazione mostra la morsettiera dell alimentatore CC. Cablare l’alimentatore CC usando i
connettori adatti all’estremità del cablaggio, come illustrato. La corretta sequenza di cablaggio è
da massa a massa, da positivo a positivo (da linea ad L) e da negativo a negativo (da neutro a N).
Tenere presente che il filo di massa deve sempre venire collegato per primo e scollegato per ultimo.
Figuren viser likestrømforsyningsenhetens tilkoplingsterminal. Likestrømforsyningsenheten
tilkoples ved hjelp av ledningsavslutningene, slik som vist i figuren. Riktig tilkoplingssekvens er
jord til jord, positiv til positv (linje til L), og negativ til negativ (nøytral til N). Husk at
jordingsledningen alltid bør tilkoples først og frakoples sist.
A figura mostra o bloco do terminal de fornecimento de corrente contínua. Ligue o fornecimento de
corrente contínua recorrendo aos terminadores localizados na extremidade do cabo, conforme
ilustrado. A sequência correcta de instalação é terra-a-terra, positivo-positivo (linha para L), e
negativo-negativo (neutro para N). Note que o fio de terra deverá ser sempre o primeiro a ser ligado,
e o último a ser desligado.
¡Atención!
Varning!
La figura muestra la caja de bornes de la fuente de alimentación de corriente continua. Cablear la
fuente de alimentación de corriente continua, usando los terminales apropiados, en el extremo del
cable tal como se muestra. Las conexiones deben realizarse en el siguiente orden: tierra con tierra,
positivo con positivo (la línea con la L) y negativo con negativo (el neutro con la N). Tenga en cuenta
que el conductor de tierra siempre tiene que conectarse el primero y desconectarse el último.
Illustrationen visar anslutningsplinten för likströmförsörjningsenheten. Koppla ledningarna till
strömförsörjningsenheten med lämpliga ledningsavslutningar som bilden visar. Korrekt
kopplingssekvens är jord till jord, positiv till positiv (linje till L) och negativ till negativ (neutral till
N). Observera att jordledningen alltid skall anslutas först och kopplas bort sist.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 77—Hazardous Voltages in WAN Ports
Warning
Hazardous network voltages are present in WAN ports regardless of whether power to the router is
OFF or ON. To avoid electric shock, use caution when working near WAN ports. When detaching
cables, detach the end away from the router first.
Waarschuwing
Er is gevaarlijke netwerkspanning aanwezig in WAN poorten ongeacht of de stroom naar de router
INGESCHAKELD of UITGESCHAKELD is. Om elektrische schokken te vermijden, dient u voorzichtig te
werk te gaan wanneer u in de nabijheid van WAN poorten werkt. Wanneer u kabels losmaakt, dient
u eerst het uiteinde dat zich het verst van de router vandaan bevindt, te verwijderen.
Varoitus
WAN-porteissa on vaarallisia verkkojännitteitä riippumatta siitä, onko reitittimen virta kytketty vai
ei. Välttyäksesi sähköiskulta ole varovainen työskennellessäsi WAN-porttien lähettyvillä. Kun
irrotat kaapeleita, irrota reitittimestä kauempana sijaitseva pää ensiksi.
Attention
Les ports de réseau longue distance (WAN) gèrent des tensions de réseau dangereuses, que le
routeur soit sous tension ou pas. Pour éviter tout risque d’électrocution, prenez toutes les
précautions nécessaires avant de travailler à proximité des ports WAN. Pour déconnecter les
câbles, commencez par débrancher l’extrémité la plus éloignée du routeur.
Warnung
Avvertenza
Advarsel
In WAN-Ports sind gefährliche Netzspannungen vorhanden, auch wenn der Strom zum Router
abgeschaltet wurde. Zur Vermeidung von Elektroschock Vorsicht bei der Arbeit in der Nähe von
WAN-Ports. Beim Abtrennen von Kabeln zuerst das vom Router entfernte Ende lösen.
Nelle porte WAN sono presenti tensioni di rete pericolose, sia che il router sia acceso o meno (ON
od OFF). Per evitare scosse elettriche, fare attenzione quando si lavora in prossimità di porte WAN.
Quando si scollegano cavi, staccare per primo il connettore collegato al router.
Det er livsfarlig nettverksspenning i WAN-utganger, uavhengig av om strømmen til
fordelingsenheten er slått av (OFF) eller på (ON). Vær forsiktig når du jobber nær WAN-utganger slik
at du unngår elektrisk støt. Hvis du skal løsne kabler, må du først løsne den enden som er lengst
borte fra fordelingsenheten.
Aviso
¡Advertencia!
Varning!
Existem sempre tensões de rede perigosas nas portas WAN, independentemente da corrente para o
dispositivo repartidor de mensagens estar ligada (ON) ou desligada (OFF). Para evitar choques
eléctricos, tenha o devido cuidado ao trabalhar perto das portas WAN. Ao desconectar os cabos,
separe primeiro a extremidade que se encontra ligada ao dispositivo repartidor de mensagens.
Hay tensiones de red peligrosas en los puertos de redes de área extendida (WAN), tanto con la
alimentación al router conectada como desconectada. Para evitar la sacudida eléctrica, proceda
con precaución cuando trabaje en las proximidades de puertos WAN. Para desconectar los cables,
desconecte primero el extremo que va al router.
Farlig nätverksspänning föreligger i WAN-portarna oavsett om strömförsörjningen till distributören
är bruten eller ej. För att undvika elektriska stötar ska du vara försiktig vid arbete i närheten av
dessa portar. När du kopplar bort en kabel ska du först koppla bort den ände som inte är ansluten till
distributören.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 87—Incorrect Connection Warning
Warning
Waarschuwing
Varoitus
Incorrect connection of this or connected equipment to a general purpose outlet could result in a
hazardous situation.
Incorrecte aansluiting van deze of aangesloten apparatuur op een stopcontact voor algemene
doeleinden kan een gevaarlijke situatie tot gevolg hebben.
Tämän laitteen tai siihen liitettyjen laitteiden virheellinen kytkentä yleispistorasiaan voi aiheuttaa
vaaratilanteen.
Attention
Un branchement incorrect de cet équipement ou de l’équipement branché à une prise d’usage
général peut créer une situation dangereuse.
Warnung
Inkorrektes Anschließen von diesem oder damit verbundenen Geräten an einer Allzwecksteckdose
kann eine Gefahrensituation verursachen.
Avvertenza
Un collegamento errato di questo apparecchio, o dell’apparecchiatura a esso collegato, a una presa
di uso generale può causare una situazione pericolosa.
Advarsel
Aviso
Feil kobling av dette utstyret eller tilhørende utstyr til et vanlig uttak kan føre til farlige situasjoner.
Uma conexão incorrecta a uma ficha de alimentação eléctrica normal, deste ou de qualquer
equipamento a este conectado, poderá resultar numa situação potencialmente perigosa.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
¡Advertencia!
Varning!
La conexión incorrecta de este equipo, o del equipo conectado, a una toma o receptáculo de tipo
general podría resultar en una situación peligrosa.
Felaktig koppling av denna eller ansluten utrustning till ett universaluttag kan orsaka riskfylld
situation.
Statement 88—Service Personnel Warning
Warning
Waarschuwing
Varoitus
This equipment is to be installed and maintained by service personnel only as defined by AS/NZS
3260 Clause 1.2.14.3 Service Personnel.
Deze apparatuur mag slechts geïnstalleerd en onderhouden worden door servicepersoneel conform
de definitie van AS/NZS 3260 Clausule 1.2.14.3 Service Personnel.
Tämän laitteen saa asentaa tai huoltaa ainoastaan Australiassa ja Uudessa Seelannissa
sovellettavan AS/NZS 3260 -standardin kohdan 1.2.14.3 Service Personnel määrittelemä
huoltohenkilöstö.
Attention
Warnung
Cet équipement ne doit être installé et entretenu que par du personnel d’entretien comme défini par
la réglementation AS/NZS 3260 Clause 1.2.14.3 Service Personnel.
Dieses Gerät darf nur von Wartungspersonal gemäß AS/NZS-Definition 3260, Paragraph 1.2.14.3,
"Service Personnel", installiert und gewartet werden.
Avvertenza
Questo apparecchio deve essere installato e mantenuto in efficienza esclusivamente da personale
tecnico che soddisfi i requisiti specificati nella sezione 1.2.14.3 sul ‘Service Personnel’ contenuta
nelle norme AS/NZS 3260.
Advarsel
Aviso
Installasjon og vedlikehold av dette utstyret skal kun foretas av vedlikeholdspersonell som definert
i AS/NZS 3260, klausul 1.2.14.3 Service Personnel.
Este equipamento deverá ser instalado e reparado apenas por pessoal de manutenção qualificado,
conforme estipulado em AS/NZS 3260 Cláusula 1.2.14.3 Service Personnel.
¡Advertencia!
Varning!
Este equipo se debe instalar y mantener solamente por personal de servicio, según definido por
AS/NZS 3260 Cláusula 1.2.14.3 Service Personnel.
Installation och underhåll av denna utrustning får endast utföras av servicepersonal enligt
definition i AS/NZS 3260 klausul 1.2.14.3 Service Personnel.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 89—Telecommunications Lines Warning
Warning
Waarschuwing
Varoitus
The telecommunications lines must be disconnected 1) before unplugging the main power connector
and/or 2) while the housing is open.
De telecommunicatielijnen moeten verbroken worden 1) voordat de hoofdvoedingsconnector
uitgeschakeld wordt en/of 2) terwijl de behuizing nog open is.
Tietoliikennelinjat on kytkettävä irti 1) ennen kuin päävirtaliitin irrotetaan pistorasiasta ja/tai 2) kun
suojus on auki.
Attention
Les lignes de télécommunications doivent être déconnectées 1) avant de débrancher le connecteur
d’alimentation principal et/ou 2) lorsque le boîtier est ouvert.
Warnung
Die Fernmeldeleitungen müssen getrennt werden, 1) bevor der Netzstecker abgezogen wird
und/oder 2) während das Gehäuse geöffnet ist.
Avvertenza
Advarsel
Le linee di telecomunicazione vanno scollegate sia prima di scollegare la spina dell’alimentazione
di rete sia prima di aprire l’involucro (non ricollegarle finché non si chiude l’involucro).
Telekommunikasjonsledningene må være frakoblet 1) før hovedstrømskoblingen kobles ut og/eller
2) når huset er åpent.
Aviso
As linhas de telecomunicações têm de ser desligadas: 1) antes de desligar o conector de corrente
principal; e/ou 2) enquanto a cobertura estiver aberta.
¡Advertencia!
Varning!
Las líneas de telecomunicaciones deben desconectarse 1) antes de desenchufar el conector
principal de energía y 2) mientras la caja esté abierta.
Telekommunikationslinjerna måste vara urkopplade 1) innan huvudströmskontakten tas ur och/eller
2) medan kåpan är öppen.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 90—Customer Equipment Warning
Warning
The E1 interface card may only be installed in an ACA-permitted customer equipment or a Data
Terminal Equipment (DTE) that is exempted from ACA’s permit requirements. The customer
equipment must only be housed in a cabinet that has screw-down lids to stop user access to
overvoltages on the customer equipment. The customer equipment has circuitry that may have
telecommunications network voltages on them.
Waarschuwing
De E1-interfacekaart mag slechts geïnstalleerd worden in door ACA toegestane apparatuur van de
klant of in Data Terminal Equipment (DTE) die vrijgesteld is van de vergunningsvereisten van ACA.
De apparatuur van de klant moet in een kastje geplaatst worden met sluitplaten die dichtgeschroefd
kunnen worden om te voorkomen dat de gebruiker toegang verkrijgt tot overspanning op de
apparatuur van de klant. De apparatuur van de klant heeft een schakelsysteem waarop
telecommunicatienetwerkspanning kan staan.
Varoitus
E1-liitäntäkortin saa asentaa ainoastaan ACA:n hyväksymiin asiakaslaitteisiin tai Data Terminal
Equipment -laitteisiin (DTE), jotka eivät kuulu ACA:n lupavaatimusten piiriin. Asiakaslaitteet on
sijoitettava koteloon, jossa on kiinni ruuvattavat kannet, jotta käyttäjä ei altistu asiakaslaitteiden
ylijännitteille. Asiakaslaitteissa on virtapiiri, jossa voi olla tietoliikenneverkkojännitteitä.
Attention
La carte d’interface E1 ne peut être installée que dans un équipement de l’utilisateur autorisé par
ACA ou dans un DTE (Data Terminal Equipment) pour lequel l’autorisation de ACA n’est pas exigée.
L’équipement de l’utilisateur ne doit être placé que dans une enceinte munie de couvercles à vis qui
empêchent l’utilisateur d’accéder aux surtensions présentes. L’équipement de l’utilisateur est muni
de circuits qui peuvent avoir des tensions de réseau de télécommunications.
Warnung
Die E1-Schnittstellenkarte darf nur in einer von der Australian Communications Authority (ACA)
zugelassenen Teilnehmereinrichtung oder einer von den ACA-Zulassungsanforderungen
ausgenommenen Datenendeinrichtung (DEE) installiert werden. Die Teilnehmereinrichtung muß in
einem Gehäuse untergebracht sein, das mit Aufschraubdeckeln versehen ist, um den Zugang der
Benutzer zu Überspannungen an der Teilnehmereinrichtung zu verhindern. In der
Teilnehmereinrichtung befinden sich Schaltkreise, an denen möglicherweise
Fernmeldenetzspannungen anliegen.
Avvertenza
Advarsel
La scheda d’interfaccia E1 può essere installata solo in un’apparecchiatura con autorizzazione ACA
o in un ‘Data Terminal Equipment (DTE)’ esente dai requisiti per l’autorizzazione ACA. La suddetta
apparecchiatura deve essere contenuta in un armadio con coperchi bloccabili con viti, per impedire
l’accesso alle sovratensioni in essa presenti; i suoi circuiti possono essere a tensioni di rete di
telecomunicazioni.
Grensesnittkortet E1 kan kun installeres i kundeutstyr som er godkjent av ACA, eller i
dataterminalutstyr (DTE) som er unndratt ACAs krav til tillatelse. Kundeutstyret må kun være
plassert i et kabinett som har lokk som er skrudd fast, for å hindre brukertilgang til overspenning på
kundeutstyret. Kundeutstyret inneholder kretser som kan ha nettverksspenning for
telekommunikasjon.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Aviso
O cartão de ligação E1 apenas poderá ser instalado em equipamento dos clientes que possuam
autorização da ACA (Australian Communications Authority) ou num DTE (Data Terminal Equipment),
que esteja isento dos requisitos de autorização da ACA. O equipamento dos clientes deverá ser
somente colocado numa caixa com tampas de aparafusar, para impossibilitar o acesso do utilizador
às altas tensões deste mesmo equipamento. O equipamento do cliente possui circuitos que poderão
ter tensões de rede de telecomunicações.
¡Advertencia!
Varning!
La tarjeta de interfaz E1 sólo se puede instalar en un equipo de cliente permitido por ACA o en un
equipo de terminal de datos (DTE) que no requiera el permiso de ACA. El equipo del cliente sólo debe
estar instalado en un armario con cubiertas atornilladas, para evitar el acceso del usuario a los
sobrevoltajes presentes en dicho equipo. El equipo del cliente tiene circuitos donde pueden estar
presentes voltajes de la red de telecomunicaciones.
E1-gränssnittskortet får endast installeras i en av ACA tillåten kundutrustning eller en Data Terminal
Equipment (DTE) som är undantagen ACA:s licenskrav. Kundutrustningen måste vara i ett skåp med
igenskruvade lock som hindrar användaren från att komma åt överspänning på kundutrustningen.
Det finns kretsar i kundutrustningen som kan ha nätverksspänning.
Statement 96—Circuit Breaker (15A) Warning
Warning
This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure
that a UL Listed and Certified fuse or circuit breaker no larger than 60 VDC, 15 A is used on all
current-carrying conductors.
Waarschuwing
Dit product is afhankelijk van de in het gebouw gebruikte installatie voor kortsluit-
(overstroom)beveiliging. Controleer of er een (UL-keurmerk) Listed en Certified zekering of
stroomverbreker van niet meer dan 60 Volt gelijkstroom, 15 A gebruikt wordt op alle leidingen die
stroom voeren.
Varoitus
Tämä tuote on riippuvainen rakennukseen asennetusta oikosulkusuojauksesta
(ylivirtasuojauksesta). Varmista, että kaikissa virroitetuissa johtimissa käytetään Yhdysvaltain
UL-testilaboratorion luetteloimaa (Underwriters Laboratory Listed) ja sertifioitua korkeintaan 60
voltin tasavirralle ja 15 ampeerin jännitteelle sopivaa sulaketta tai suojakytkintä.
Attention
Warnung
Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit dépend de
l’installation du local. Vérifier qu’un fusible ou un disjoncteur homologué et classé UL de 60 V cc, 15
A maximum est utilisé sur les conducteurs de charge.
Dieses Produkt ist darauf angewiesen, daß im Gebäude ein Kurzschluß- bzw. Überstromschutz
installiert ist. Stellen Sie sicher, daß eine Sicherung oder ein Unterbrecher (von der UL registriert
und zertifiziert) von nicht mehr als 240 V Wechselstrom, 10 A (bzw. in den USA 120 V Wechselstrom,
15 A) an allen stromführenden Leitern verwendet wird.
Avvertenza
La protezione di questo prodotto contro il cortocircuito (sovracorrente) dipende dall’impianto
dell’edificio. Accertarsi che tutti i conduttori di fase siano protetti da fusibili o interruttori UL
automatici di portata non superiore a 60 V c.c., 15 A.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Advarsel
Aviso
Dette produktet er avhengig av bygningens installasjoner av kortslutningsbeskyttelse (overstrøm).
Kontroller at det brukes en registrert (av Underwriters Laboratory) og godkjent sikring eller
strømbryter som ikke er større enn 60 VDC, 15 A på alle de strømførende lederne.
Este produto depende da instalação existente para obter protecção contra curto-circuito
(sobrecarga). Certifique-se de que um fusível ou disjuntor listado e certificado (de acordo com os
requisitos UL), não superior a 60 VAC, 15A, é utilizado em todos os condutores de transporte de
corrente.
¡Advertencia!
Varning!
Este producto depende de la protección contra cortocircuitos (sobrecorrientes) de la instalación
eléctrica del edificio. Asegurarse de que todos los conductores portadoresde corriente estén
protegidos por un fusible o interruptor automático aprobado por Underwriters Laboratory (UL) y
certificado por una agencia local de seguridad, y que tenga una capacidad no mayor de 60 voltios
de corriente directa y 15 amperios.
Denna produkt är beroende av i byggnaden installerat kortslutningsskydd (överströmsskydd).
Kontrollera att säkring eller överspänningsskydd som är "Listed" av Underwriters Laboratory samt
certifierad för bruk med max. 60 V likström, 15 A används på samtliga strömförande ledare.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 140—Chassis Power Connection
Warning
Before connecting or disconnecting ground or power wires to the chassis, ensure that power is
removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel
board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch
handle of the circuit breaker in the OFF position.
Waarschuwing
Voordat u aarddraden of elektriciteitsdraden op het frame aansluit of van het frame neemt, dient u
te controleren of de stroom naar het gelijkstroomcircuit uitgeschakeld is. Om u ervan te verzekeren
dat alle stroom UIT is geschakeld, kiest u op het schakelbord de stroomverbreker die het
gelijkstroomcircuit bedient, draait de stroomverbreker naar de UIT positie en plakt de
schakelaarhendel van de stroomverbreker met plakband in de UIT positie vast.
Varoitus
Attention
Warnung
Varmista, että tasavirtapiirissä ei ole virtaa ennen maadoitus- tai virtajohtojen kytkemistä
asennuspohjaan tai ennen niiden irrottamista. Varmistaaksesi, että virta on KATKAISTU täysin,
paikanna tasavirrasta huolehtivassa kojetaulussa sijaitseva suojakytkin, käännä suojakytkin
KATKAISTU-asentoon ja teippaa suojakytkimen varsi niin, että se pysyy KATKAISTU-asennossa.
Avant de connecter ou de déconnecter les câbles d'alimentation (pôles et terre) du châssis, vérifiez
que le circuit de courant continu est hors tension : localisez le disjoncteur sur le panneau de
commande du circuit de courant continu, poussez-le sur la position fermée (OFF) et, à l'aide d'un
ruban adhésif, bloquez sa poignée sur cette position.
Gleichstrom-Unterbrechung Bevor Sie Erdungs- oder Stromkabel an das Chassis anschließen oder
von ihm abtrennen, ist sicherzustellen, daß der Gleichstrom-Stromkreis unterbrochen ist. Um
sicherzustellen, daß sämtlicher Strom AUS ist, machen Sie auf der Schalttafel den Unterbrecher für
die Gleichstromschaltung ausfindig, stellen Sie den Unterbrecher auf OFF, und kleben Sie den
Schaltergriff des Unterbrechers mit Klebeband in der AUS-Stellung fest.
Avvertenza
Advarsel
Aviso
Prima di collegare o distaccare i cavi elettrici o di messa a terra dallo chassis, assicuratevi che il
circuito DC non sia alimentato. Per verificare che tutta l'alimentazione sia scollegata (OFF),
individuare l'interruttore automatico sul quadro strumenti che alimenta il circuito CC, mettere
l'interruttore in posizione OFF e fissarlo con nastro adesivo in tale posizione.
Før til- eller frakobling av jord- og strømledninger til kabinettet, kontroller at strømmen er frakoblet
likestrømkretsen. Sørg for at all strøm er slått AV. Dette gjøres ved å lokalisere strømbryteren på
brytertavlen som betjener likestrømkretsen, slå strømbryteren AV og teipe bryterhåndtaket på
strømbryteren i AV-stilling.
Antes de conectar ou desconectar a ligação à terra ou a alimentação do chassis, certifique-se de
que desligou a fonte de alimentação de energia do circuito de corrente contínua. Para se assegurar
que toda a corrente foi DESLIGADA, localize o disjuntor no painel que serve o circuito de corrente
contínua e coloque-o na posição OFF (Desligado), segurando nessa posição a manivela do
interruptor do disjuntor com fita isoladora.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
¡Advertencia!
Varning!
Antes de conectar o desconectar el circuito de tierra o de alimentación del chasis, asegúrese que
la alimentación del circuito CC esté cortada (OFF). Para asegurarse de que toda la alimentación esté
cortada (OFF), localice el interruptor automático en el panel que alimenta el circuito de corriente
continua, cambie el interruptor automático a la posición de apagado (OFF) y sujete con cinta la
palanca del interruptor automático en posición de apagado (OFF).
Innan du kopplar jord- eller elledningar till eller från chassit måste du kontrollera att
strömförsörjningen till likströmskretsen är bruten. Kontrollera att all strömförsörjning är BRUTEN
genom att slå AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast
överspänningsskyddets omkopplare i FRÅN-läget.
Statement 197—DC Power Supply Warning
Warning
The illustration shows the DC power supply terminal block. Wire the DC power supply using the
appropriate lugs at the wiring end, or with no lugs, as illustrated. The proper wiring sequence is
ground to ground, positive to positive, and negative to negative. Note that the ground wire should
always be connected first and disconnected last.
Waarschuwing
De figuur toont de aansluitstrip van de gelijkstroomvoeding. Breng de bedrading aan voor de
gelijkstroomvoeding met behulp van de juiste aansluitpunten aan het draadeinde zoals aangegeven.
De juiste bedradingsvolgorde is aarde naar aarde, positief naar positief en negatief naar negatief.
Let op dat de aarddraad altijd het eerst verbonden en het laatst losgemaakt wordt.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Varoitus
Kuva esittää tasavirran pääterasiaa. Kytke tasavirtalähde sen kiinnitysalustaan joko korvakkeilla
tai ilman niitä kuvan esittämällä tavalla. Oikea kytkentäjärjestys on seuraava: maajohto
maajohtoon, positiivinen positiiviseen ja negatiivinen negatiiviseen. Muista, että maajohto
yhdistetään aina ensin ja irrotetaan viimeisenä.
Attention
La figure illustre le bloc de connexion de l'alimentation en courant continu. Câblez l'alimentation
en courant continu en fixant les cosses appropriées aux extrémités câblées ou sans utiliser de
cosses, conformément au schéma. La séquence de câblage à suivre est terre-terre, positif-positif, et
négatif-négatif. Notez que le fil de masse doit toujours être connecté en premier et déconnecté en
dernier.
Warnung
Die Abbildung zeigt den Terminalblock des Gleichstrom-Netzgeräts. Verdrahten Sie das
Gleichstrom-Netzgerät unter Verwendung von geeigneten Kabelschuhen am Verdrahtungsende oder
ohne Kabelschuhe (siehe Abbildung). Die richtige Verdrahtungsfolge ist Erde an Erde, positiv an
positiv und negativ an negativ. Beachten Sie bitte, daß der Erdungsdraht immer als erster verbunden
und als letzter abgetrennt werden sollte.
Avvertenza
Advarsel
Aviso
L’illustrazione mostra la morsettiera dell alimentatore CC. Cablare l’alimentatore CC usando i
connettori adatti all’estremità del cablaggio, oppure senza capicorda, come illustrato. La corretta
sequenza di cablaggio è da massa a massa, da positivo a positivo e da negativo a negativo. Tenere
presente che il filo di massa deve sempre venire collegato per primo e scollegato per ultimo.
Figuren viser likestrømforsyningsenhetens tilkoplingsterminal. Likestrømforsyningsenheten
tilkoples ved hjelp av passende kabelsko som festes i enden av ledningene, slik som vist i figuren.
Riktig tilkoplingssekvens er jord til jord, positiv til positv, og negativ til negativ. Husk at
jordingsledningen alltid bør tilkoples først og frakoples sist.
A figura mostra o bloco do terminal de fornecimento de corrente contínua. Ligue o fornecimento de
corrente contínua utilizando os bornes apropriados na extremidade do cabo, ou sem bornes,
conforme ilustrado. A sequência correcta de instalação é terra-a-terra, positivo-positivo, e
negativo-negativo. Note que o fio de terra deverá ser sempre o primeiro a ser ligado, e o último a ser
desligado.
¡Advertencia!
Varning!
La figura muestra la caja de bornes de la fuente de alimentación. Cablee la fuente de alimentación
de corriente continua, utilizando las lengüetas de conexión apropiadas en el extremo del cable, tal
como se muestra, o sin lengüetas. Las conexiones deben realizarse en el siguiente orden: tierra con
tierra, positivo con positivo y negativo con negativo. Tenga en cuenta que el conductor de tierra
siempre tiene que conectarse el primero y desconectarse el último.
Illustrationen visar anslutningsplinten för likströmförsörjningsenheten. Koppla ledningarna till
strömförsörjningsenheten med lämpliga kabelskor, eller utan kabelskor, i ledningsändarna som
bilden visar. Korrekt kopplingssekvens är jord till jord, positiv till positiv och negativ till negativ.
Observera att jordledningen alltid skall anslutas först och kopplas bort sist.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 1001—Work During Lightning Activity
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Waarschuwing
Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan
te sluiten of te ontkoppelen.
Varoitus
Attention
Warnung
Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla.
Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.
Arbeiten Sie nicht am System und schließen Sie keine Kabel an bzw. trennen Sie keine ab, wenn
es gewittert.
Avvertenza
Advarsel
Non lavorare sul sistema o collegare oppure scollegare i cavi durante un temporale con fulmini.
Utfør aldri arbeid på systemet, eller koble kabler til eller fra systemet når det tordner eller lyner.
Não trabalhe no sistema ou ligue e desligue cabos durante períodos de mau tempo (trovoada).
Aviso
¡Advertencia!
No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas
eléctricas en la atmósfera.
Varning!
Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 1003—DC Power Disconnection
Warning
Before performing any of the following procedures, ensure that power is removed from the
DC circuit.
Waarschuwing
Voordat u een van de onderstaande procedures uitvoert, dient u te controleren of de stroom naar het
gelijkstroom circuit uitgeschakeld is.
Varoitus
Varmista, että tasavirtapiirissä ei ole virtaa ennen seuraavien toimenpiteiden suorittamista.
Attention
Avant de pratiquer l'une quelconque des procédures ci-dessous, vérifier que le circuit en courant
continu n'est plus sous tension.
Warnung
Vor Ausführung der folgenden Vorgänge ist sicherzustellen, daß die Gleichstromschaltung
keinen Strom erhält.
Avvertenza
Prima di svolgere una qualsiasi delle procedure seguenti, verificare che il circuito CC non
sia alimentato.
Advarsel
Aviso
Før noen av disse prosedyrene utføres, kontroller at strømmen er frakoblet likestrømkretsen.
Antes de executar um dos seguintes procedimentos, certifique-se que desligou a fonte de
alimentação de energia do circuito de corrente contínua.
¡Advertencia!
Varning!
Antes de proceder con los siguientes pasos, comprobar que la alimentación del circuito de
corriente continua (CC) esté cortada (OFF).
Innan du utför någon av följande procedurer måste du kontrollera att strömförsörjningen till
likströmskretsen är bruten.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Aviso
Antes de executar qualquer um dos procedimentos a seguir, verifique se a energia foi removida do
circuito DC.
Advarsel
Før du udfører nogen af følgende procedurer, skal du sikre dig, at der ikke er strøm til
jævnstrømskredsløbet.
Statement 1004—Installation Instructions
Warning
Waarschuwing
Varoitus
Read the installation instructions before connecting the system to the power source.
Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron aansluit.
Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Attention
Warnung
Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen.
Consultare le istruzioni di installazione prima di collegare il sistema all'alimentatore.
Les installasjonsinstruksjonene før systemet kobles til strømkilden.
Avvertenza
Advarsel
Aviso
Leia as instruções de instalação antes de ligar o sistema à fonte de energia.
¡Advertencia!
Varning!
Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Läs installationsanvisningarna innan du kopplar systemet till strömförsörjningsenheten.
Statement 1015—Battery Handling
Warning
Waarschuwing
Varoitus
There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with
the same or equivalent type recommended by the manufacturer. Dispose of used batteries according
to the manufacturer’s instructions.
Er is ontploffingsgevaar als de batterij verkeerd vervangen wordt. Vervang de batterij slechts met
hetzelfde of een equivalent type dat door de fabrikant aanbevolen is. Gebruikte batterijen dienen
overeenkomstig fabrieksvoorschriften weggeworpen te worden.
Räjähdyksen vaara, jos akku on vaihdettu väärään akkuun. Käytä vaihtamiseen ainoastaan saman-
tai vastaavantyyppistä akkua, joka on valmistajan suosittelema. Hävitä käytetyt akut valmistajan
ohjeiden mukaan.
Attention
Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile
de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées
conformément aux instructions du fabricant.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Warnung
Avvertenza
Advarsel
Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch
den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien
nach den Anweisungen des Herstellers.
Pericolo di esplosione se la batteria non è installata correttamente. Sostituire solo con una di tipo
uguale o equivalente, consigliata dal produttore. Eliminare le batterie usate secondo le istruzioni
del produttore.
Det kan være fare for eksplosjon hvis batteriet skiftes på feil måte. Skift kun med samme eller
tilsvarende type som er anbefalt av produsenten. Kasser brukte batterier i henhold til produsentens
instruksjoner.
Aviso
Existe perigo de explosão se a bateria for substituída incorrectamente. Substitua a bateria por uma
bateria igual ou de um tipo equivalente recomendado pelo fabricante. Destrua as baterias usadas
conforme as instruções do fabricante.
¡Advertencia!
Varning!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Reemplazar la batería
exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante. Desechar las
baterías gastadas según las instrucciones del fabricante.
Explosionsfara vid felaktigt batteribyte. Ersätt endast batteriet med samma batterityp som
rekommenderas av tillverkaren eller motsvarande. Följ tillverkarens anvisningar vid kassering av
använda batterier.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 1017—Restricted Area
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be
accessed only through the use of a special tool, lock and key, or other means of security.
Waarschuwing
Deze eenheid is bestemd voor installatie in plaatsen met beperkte toegang. Toegang tot een
dergelijke plaats kan alleen verkregen worden door middel van een speciaal instrument, een slot
en sleutel of een ander veiligheidsmiddel.
Varoitus
Tämä laite on tarkoitettu asennettavaksi paikkaan, johon pääsy on rajoitettua. Tällaiseen paikkaan
pääsee vain erikoistyökalua, lukkoon sopivaa avainta tai jotakin muuta turvalaitetta käyttämällä.
Attention
Cet appareil est à installer dans des zones d'accès réservé. L'accès à une zone d'accès réservé n'est
possible qu'en utilisant un outil spécial, un mécanisme de verrouillage et une clé, ou tout autre
moyen de sécurité.
Warnung
Avvertenza
Advarsel
Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu
derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer
sonstigen Sicherheitsvorkehrung möglich.
Questa unità è prevista per essere installata in un'area ad accesso limitato, vale a dire un'area
accessibile solo mediante l'uso di un attrezzo speciale, come lucchetto e chiave, o altri dispositivi
di sicurezza.
Denne enheten er beregnet på installasjon i områder med begrenset tilgang. Et begrenset
tilgangsområde kan bare nås ved hjelp av et spesielt verktøy, lås og nøkkel, eller andre
sikkerhetsanordninger.
Aviso
Esta unidade foi concebida para instalação em áreas de acesso restrito. Uma área de acesso restrito
é uma área à qual apenas tem acesso o pessoal de serviço autorizado, que possua uma ferramenta,
chave e fechadura especial, ou qualquer outra forma de segurança.
¡Advertencia!
Varning!
Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse
acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con
llave u otro medio de seguridad.
Denna enhet är avsedd för installation i områden med begränsat tillträde. Ett område med begränsat
tillträde kan endast tillträdas med hjälp av specialverktyg, lås och nyckel eller annan
säkerhetsanordning.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Aviso
Esta unidade deve ser instalada em áreas de acesso restrito. Uma área de acesso restrito só pode
ser acessada com o uso de uma ferramenta especial, cadeado e chave ou outros meios de
segurança.
Advarsel
Denne enhed er beregnet til installation i områder med begrænset adgang. Der kan kun opnås
adgang til et begrænset område ved at bruge et særligt stykke værktøj, lås og nøgle, eller en anden
form for sikkerhed.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 1019—Main Disconnecting Device
Warning
The plug-socket combination must be accessible at all times, because it serves as the main
disconnecting device.
Waarschuwing
De combinatie van de stekker en het elektrisch contactpunt moet te allen tijde toegankelijk zijn
omdat deze het hoofdmechanisme vormt voor verbreking van de aansluiting.
Varoitus
Pistoke/liitinkohta toimii pääkatkaisumekanismina. Pääsy siihen on pidettävä aina esteettömänä.
Attention
La combinaison de prise de courant doit être accessible à tout moment parce qu'elle fait office de
système principal de déconnexion.
Warnung
Avvertenza
Advarsel
Der Netzkabelanschluß am Gerät muß jederzeit zugänglich sein, weil er als primäre
Ausschaltvorrichtung dient.
Il gruppo spina-presa deve essere sempre accessibile, poiché viene utilizzato come dispositivo di
scollegamento principale.
Kombinasjonen støpsel/uttak må alltid være tilgjengelig ettersom den fungerer som
hovedfrakoplingsenhet.
Aviso
A combinação ficha-tomada deverá ser sempre acessível, porque funciona como interruptor
principal.
¡Advertencia!
Varning!
El conjunto de clavija y toma ha de encontrarse siempre accesible ya que hace las veces de
dispositivo de desconexión principal.
Man måste alltid kunna komma åt stickproppen i uttaget, eftersom denna koppling utgör den
huvudsakliga frånkopplingsanordningen.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 1021—SELV Circuit
Warning
To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to
telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain
TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution when
connecting cables.
Waarschuwing
Om elektrische schokken te vermijden, mogen veiligheidscircuits met extra lage spanning
(genaamd SELV = Safety Extra-Low Voltage) niet met telefoonnetwerkspanning (TNV) circuits
verbonden worden. LAN (Lokaal netwerk) poorten bevatten SELV circuits en WAN (Regionaal
netwerk) poorten bevatten TNV circuits. Sommige LAN en WAN poorten gebruiken allebei RJ-45
connectors. Ga voorzichtig te werk wanneer u kabels verbindt.
Varoitus
Jotta vältyt sähköiskulta, älä kytke pienjännitteisiä SELV-suojapiirejä puhelinverkkojännitettä
(TNV) käyttäviin virtapiireihin. LAN-portit sisältävät SELV-piirejä ja WAN-portit
puhelinverkkojännitettä käyttäviä piirejä. Osa sekä LAN- että WAN-porteista käyttää
RJ-45-liittimiä. Ole varovainen kytkiessäsi kaapeleita.
Attention
Pour éviter une électrocution, ne raccordez pas les circuits de sécurité basse tension (Safety
Extra-Low Voltage ou SELV) à des circuits de tension de réseau téléphonique (Telephone Network
Voltage ou TNV). Les ports du réseau local (LAN) contiennent des circuits SELV et les ports du réseau
longue distance (WAN) sont munis de circuits TNV. Certains ports LAN et WAN utilisent des
connecteurs RJ-45. Raccordez les câbles en prenant toutes les précautions nécessaires.
Warnung
Avvertenza
Advarsel
Zur Vermeidung von Elektroschock die Sicherheits-Kleinspannungs-Stromkreise (SELV-Kreise)
nicht an Fernsprechnetzspannungs-Stromkreise (TNV-Kreise) anschließen. LAN-Ports enthalten
SELV-Kreise, und WAN-Ports enthalten TNV-Kreise. Einige LAN- und WAN-Ports verwenden auch
RJ-45-Steckverbinder. Vorsicht beim Anschließen von Kabeln.
Per evitare scosse elettriche, non collegare circuiti di sicurezza a tensione molto bassa (SELV) ai
circuiti a tensione di rete telefonica (TNV). Le porte LAN contengono circuiti SELV e le porte WAN
contengono circuiti TNV. Alcune porte LAN e WAN fanno uso di connettori RJ-45. Fare attenzione
quando si collegano cavi.
Unngå å koble lavspenningskretser (SELV) til kretser for telenettspenning (TNV), slik at du unngår
elektrisk støt. LAN-utganger inneholder SELV-kretser og WAN-utganger inneholder TNV-kretser. Det
finnes både LAN-utganger og WAN-utganger som bruker RJ-45-kontakter. Vær forsiktig når du
kobler kabler.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Aviso
Para evitar choques eléctricos, não conecte os circuitos de segurança de baixa tensão (SELV) aos
circuitos de tensão de rede telefónica (TNV). As portas LAN contêm circuitos SELV e as portas WAN
contêm circuitos TNV. Algumas portas LAN e WAN usam conectores RJ-45. Tenha o devido cuidado
ao conectar os cabos.
¡Advertencia!
Para evitar la sacudida eléctrica, no conectar circuitos de seguridad de voltaje muy bajo (safety
extra-low voltage = SELV) con circuitos de voltaje de red telefónica (telephone network voltage =
TNV). Los puertos de redes de área local (local area network = LAN) contienen circuitos SELV, y los
puertos de redes de área extendida (wide area network = WAN) contienen circuitos TNV. En algunos
casos, tanto los puertos LAN como los WAN usan conectores RJ-45. Proceda con precaución al
conectar los cables.
Varning!
För att undvika elektriska stötar, koppla inte säkerhetskretsar med extra låg spänning
(SELV-kretsar) till kretsar med telefonnätspänning (TNV-kretsar). LAN-portar innehåller
SELV-kretsar och WAN-portar innehåller TNV-kretsar. Vissa LAN- och WAN-portar är försedda med
RJ-45-kontakter. Iaktta försiktighet vid anslutning av kablar.
Statement 1022—Disconnect Device
Warning
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Waarschuwing
Er moet een gemakkelijk toegankelijke, tweepolige stroomverbreker opgenomen zijn in de
vaste bedrading.
Varoitus
Kiinteään johdotukseen on liitettävä kaksinapainen kytkinlaite, johon on helppo päästä käsiksi.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Attention
Warnung
Avvertenza
Advarsel
Aviso
Un disjoncteur bipolaire facile d’accès doit être intégré dans le câblage fixe.
Die feste Verdrahtung muß eine leicht zugängliche, zweipolige Trennvorrichtung enthalten.
Nei cablaggi fissi va incorporato un sezionatore a due poli facilmente accessibile.
En lett tilgjengelig, topolet frakoblingsenhet må være innebygd i det faste ledningsnettet.
Deverá incorporar-se um dispositivo de desconexão de dois pólos de acesso fácil, na instalação
eléctrica fixa.
Advertencia
Varning!
El cableado fijo debe incorporar un dispositivo de desconexión de dos polos y de acceso fácil.
En lättillgänglig tvåpolig frånkopplingsenhet måste ingå i den fasta kopplingen.
Aviso
Um dispositivo de desconexão de dois pólos de fácil acesso deve ser incorporado à fiação fixa.
En to-polet afmonteringsenhed med nem adgang skal integreres i det faste ledningsnet.
Advarsel
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 1023—No. 26 AWG
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Waarschuwing
Om brandgevaar te reduceren, dient slechts telecommunicatielijnsnoer nr. 26 AWG of groter
gebruikt te worden.
Varoitus
Tulipalovaaran vähentämiseksi käytä ainoastaan nro 26 AWG- tai paksumpaa tietoliikennejohdinta.
Attention
Pour réduire le risque d’incendie, n’utiliser que des cordons de lignes de télécommunications de
type AWG nº 26 ou plus larges.
Warnung
Avvertenza
Advarsel
Aviso
Zur Reduzierung der Feuergefahr eine Fernmeldeleitungsschnur der Größe 26 AWG oder
größer verwenden.
Per ridurre il rischio di incendio, usare solo un cavo per linea di telecomunicazioni di sezione
0,12 mm2 (26 AWG) o maggiore.
Bruk kun AWG nr. 26 eller telekommunikasjonsledninger med større dimensjon for å redusere faren
for brann.
Para reduzir o risco de incêndio, utilize apenas terminais de fio de telecomunicações Nº. 26 AWG
ou superiores.
Advertencia
Varning!
Para reducir el riesgo de incendios, usar sólo líneas de telecomunicaciones de calibre No. 26 AWG
o más gruesas.
För att minska brandrisken skall endast Nr. 26 AWG eller större telekommunikationsledning
användas.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 1026—WAN Port Static Shock
Warning
Hazardous network voltages are present in WAN ports regardless of whether power to the unit is
OFF or ON. To avoid electric shock, use caution when working near WAN ports. When detaching
cables, detach the end away from the unit first.
Waarschuwing
Er is gevaarlijke netwerkspanning aanwezig in WAN poorten ongeacht of de stroom naar de router
INGESCHAKELD of UITGESCHAKELD is. Om elektrische schokken te vermijden, dient u voorzichtig te
werk te gaan wanneer u in de nabijheid van WAN poorten werkt. Wanneer u kabels losmaakt, dient
u eerst het uiteinde dat zich het verst van de eenheid vandaan bevindt, te verwijderen.
Varoitus
WAN-porteissa on vaarallisia verkkojännitteitä riippumatta siitä, onko yksikön virta kytketty vai ei.
Välttyäksesi sähköiskulta ole varovainen työskennellessäsi WAN-porttien lähettyvillä. Kun irrotat
kaapeleita, irrota yksiköstä kauimpana sijaitseva pää ensiksi.
Attention
Les ports de réseau longue distance (WAN) gèrent des tensions de réseau dangereuses, que l'unité
soit sous tension ou pas. Pour éviter tout risque d’électrocution, prenez toutes les précautions
nécessaires avant de travailler à proximité des ports WAN. Pour déconnecter les câbles,
commencez par débrancher l’extrémité la plus éloignée du routeur.
Warnung
Avvertenza
Advarsel!
Aviso
In WAN-Ports sind gefährliche Netzspannungen vorhanden, auch wenn der Strom zur Einheit
abgeschaltet wurde. Zur Vermeidung von Elektroschock Vorsicht bei der Arbeit in der Nähe von
WAN-Ports. Beim Abtrennen von Kabeln zuerst das vom Router entfernte Ende lösen.
Nelle porte WAN sono presenti tensioni di rete pericolose, sia che il sistema sia acceso o meno (ON
od OFF). Per evitare scosse elettriche, fare attenzione quando si lavora in prossimità di porte WAN.
Quando si scollegano cavi, staccare per primo il connettore collegato al router.
Det er livsfarlig nettverksspenning i WAN-utganger, uavhengig av om strømmen til enheten er slått
av (OFF) eller på (ON). Vær forsiktig når du jobber nær WAN-utganger slik at du unngår elektrisk støt.
Hvis du skal løsne kabler, må du først løsne den enden som er lengst borte fra fordelingsenheten.
Existem sempre tensões de rede perigosas nas portas WAN, independentemente da corrente para a
unidade estar desligada (OFF) ou ligada (ON). Para evitar choques eléctricos, tenha o devido
cuidado ao trabalhar junto das portas WAN. Ao desconectar os cabos, separe primeiro a
extremidade do cabo que se encontra ligada à unidade.
¡Advertencia!
En los puertos de redes de área extendida (WAN) existen tensiones de red peligrosas, tanto si la
unidad está conectada como si está desconectada. Para evitar descargas eléctricas, proceda con
precaución cuando trabaje cerca de los puertos WAN. Para desconectar los cables, desconecte
primero el extremo que va a la unidad.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Varning!
Farlig nätverksspänning föreligger i WAN-portarna oavsett om strömförsörjningen till enheten är
bruten eller ej. För att undvika elektriska stötar ska du vara försiktig vid arbete i närheten av dessa
portar. När du kopplar bort en kabel ska du först koppla bort den ände som inte är ansluten
till enheten.
Statement 1040—Product Disposal
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations.
Waarschuwing
Het uiteindelijke wegruimen van dit product dient te geschieden in overeenstemming met alle
nationale wetten en reglementen.
Varoitus
Tämä tuote on hävitettävä kansallisten lakien ja määräysten mukaisesti.
Attention
La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives
de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
Warnung
Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes
erfolgen.
Avvertenza
Advarsel
Lo smaltimento di questo prodotto deve essere eseguito secondo le leggi e regolazioni locali.
Endelig kassering av dette produktet skal være i henhold til alle relevante nasjonale lover og
bestemmelser.
Aviso
Deitar fora este produto em conformidade com todas as leis e regulamentos nacionais.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
¡Advertencia!
Varning!
Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
Vid deponering hanteras produkten enligt gällande lagar och bestämmelser.
Aviso
O descarte definitivo deste produto deve estar de acordo com todas as leis e regulamentações
nacionais.
Advarsel
Endelig bortskaffelse af dette produkt skal ske i henhold til gældende love og regler.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 1041—Disconnecting Telephone-Network Cables
Warning
Waarschuwing
Varoitus
Before opening the unit, disconnect the telephone-network cables to avoid contact with
telephone-network voltages.
Voordat u de eenheid opent, dient u de verbinding met het telefoonnetwerk te verbreken door de
kabels te ontkoppelen om zo contact met telefoonnetwerk-spanning te vermijden.
Vältä joutumista kosketuksiin puhelinverkkojännitteiden kanssa irrottamalla puhelinverkoston
kaapelit ennen yksikön aukaisemista.
Attention
Pour éviter tout risque de choc électrique (tensions présentes dans l'unité), débranchez les câbles
du réseau téléphonique AVANT d'ouvrir l'unité.
Warnung
Bevor Sie das Gerät öffnen, ziehen Sie die Telefonnetzkabel aus der Verbindung, um Kontakt mit
Telefonnetzspannungen zu vermeiden.
Avvertenza
Advarsel
Prima di aprire l'unità, scollegare i cavi della rete telefonica per evitare di entrare in contatto con
la tensione di rete.
Før enheten åpnes, skal kablene for telenettet kobles fra for å unngå å komme i kontakt med
spenningen i telenettet.
Aviso
Antes de abrir a unidade, desligue os cabos da rede telefónica para evitar contacto com a tensão da
respectiva rede.
¡Advertencia!
Varning!
Antes de abrir la unidad, desconectar el cableado dirigido a la red telefónica para evitar contacto
con voltajes de la propia red.
Koppla loss ledningarna till telefonnätet innan du öppnar enheten så att kontakten med
telefonnätsspänningen bryts.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 1046—Installing or Replacing the Unit
Warning
Waarschuwing
Varoitus
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Bij installatie of vervanging van het toestel moet de aardverbinding altijd het eerste worden
gemaakt en het laatste worden losgemaakt.
Laitetta asennettaessa tai korvattaessa on maahan yhdistäminen aina tehtävä ensiksi ja
maadoituksen irti kytkeminen viimeiseksi.
Attention
Lors de l’installation ou du remplacement de l’appareil, la mise à la terre doit toujours être
connectée en premier et déconnectée en dernier.
Warnung
Der Erdanschluß muß bei der Installation oder beim Austauschen der Einheit immer zuerst
hergestellt und zuletzt abgetrennt werden.
Avvertenza
In fase di installazione o sostituzione dell'unità, eseguire sempre per primo il collegamento a massa
e disconnetterlo per ultimo.
Advarsel
Aviso
Når enheten installeres eller byttes, må jordledningen alltid tilkobles først og frakobles sist.
Ao instalar ou substituir a unidade, a ligação à terra deverá ser sempre a primeira a ser ligada, e a
última a ser desligada.
¡Advertencia!
Varning!
Al instalar o sustituir el equipo, conecte siempre la toma de tierra al principio y desconéctela
al final.
Vid installation eller utbyte av enheten måste jordledningen alltid anslutas först och kopplas
bort sist.
Aviso
Ao instalar ou substituir a unidade, a conexão terra sempre deve ser executada primeiro e
desconectada em seguida.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Advarsel
Ved installation og genmontering af enheden, skal jordforbindelsen altid installeres først og
afinstalleres sidst.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 1071—Warning Definition
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this
device.
SAVE THESE INSTRUCTIONS
Waarschuwing
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan
veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij
elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard
praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de
waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt
raadplegen.
BEWAAR DEZE INSTRUCTIES
Varoitus
TÄRKEITÄ TURVALLISUUSOHJEITA
Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin
käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu
onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen
mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien
lausuntonumeroiden avulla.
SÄILYTÄ NÄMÄ OHJEET
Attention
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant
entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez
conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures
couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des
avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la fin de chaque avertissement.
CONSERVEZ CES INFORMATIONS
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Warnung
Avvertenza
Advarsel
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen
kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und
den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder
Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
IMPORTANTI ISTRUZIONI SULLA SICUREZZA
Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle
persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli
relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti.
Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le
traduzioni delle avvertenze riportate in questo documento.
CONSERVARE QUESTE ISTRUZIONI
VIKTIGE SIKKERHETSINSTRUKSJONER
Dette advarselssymbolet betyr fare. Du er i en situasjon som kan føre til skade på person. Før du
begynner å arbeide med noe av utstyret, må du være oppmerksom på farene forbundet med
elektriske kretser, og kjenne til standardprosedyrer for å forhindre ulykker. Bruk nummeret i slutten
av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne
enheten.
TA VARE PÅ DISSE INSTRUKSJONENE
Aviso
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você está em uma situação que poderá ser causadora de
lesões corporais. Antes de iniciar a utilização de qualquer equipamento, tenha conhecimento dos
perigos envolvidos no manuseio de circuitos elétricos e familiarize-se com as práticas habituais de
prevenção de acidentes. Utilize o número da instrução fornecido ao final de cada aviso para
localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo.
GUARDE ESTAS INSTRUÇÕES
¡Advertencia!
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular
cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los
procedimientos estándar de prevención de accidentes. Al final de cada advertencia encontrará el
número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña
a este dispositivo.
GUARDE ESTAS INSTRUCCIONES
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Varning!
VIKTIGA SÄKERHETSANVISNINGAR
Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada.
Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och
känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av
varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna
anordning.
SPARA DESSA ANVISNINGAR
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Aviso
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões
corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os
circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o
número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de
segurança traduzidos que acompanham o dispositivo.
GUARDE ESTAS INSTRUÇÕES
Advarsel
VIGTIGE SIKKERHEDSANVISNINGER
Dette advarselssymbol betyder fare. Du befinder dig i en situation med risiko for
legemesbeskadigelse. Før du begynder arbejde på udstyr, skal du være opmærksom på de
involverede risici, der er ved elektriske kredsløb, og du skal sætte dig ind i standardprocedurer til
undgåelse af ulykker. Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de
oversatte advarsler, der fulgte med denne enhed.
GEM DISSE ANVISNINGER
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Warnings
Statement 1074—Comply with Local and National Electrical Codes
Warning
Installation of the equipment must comply with local and national electrical codes.
Waarschuwing
Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale
elektriciteitsvoorschriften.
Varoitus
Attention
Warnung
Avvertenza
Advarsel
Aviso
Laitteisto tulee asentaa paikallisten ja kansallisten sähkömääräysten mukaisesti.
L'équipement doit être installé conformément aux normes électriques nationales et locales.
Die Installation der Geräte muss den Sicherheitsstandards entsprechen.
L'installazione dell'impianto deve essere conforme ai codici elettrici locali e nazionali.
Installasjon av utstyret må samsvare med lokale og nasjonale elektrisitetsforskrifter.
A instalação do equipamento tem de estar em conformidade com os códigos eléctricos locais e
nacionais.
¡Advertencia!
La instalación del equipo debe cumplir con las normativas de electricidad locales y nacionales.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
52
Download from Www.Somanuals.com. All Manuals Search And Download.
United States
Varning!
Installation av utrustningen måste ske i enlighet med gällande elinstallationsföreskrifter.
United States
The channelized T3 trunk card meets the United States requirements for T3 support as specified in FCC
Part 68 standards.
FCC Rules, Part 68
1. FCC Part 68 Registration
The Cisco AS5400, Cisco AS5400HPX, and Cisco AS5400XM systems comply with FCC Rules,
Part 68. On the cover of this equipment is a label that contains, among other information, the FCC Part
68 registration number.
2. Service
In the event of equipment malfunction, all repairs should be performed by Cisco Systems or an
authorized agent. It is the responsibility of users requiring service to report the need for service to
Cisco Systems or to one of our authorized agents.
Service can be facilitated through our office at:
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-4567
Telephone: 408 526-4000
The telephone company can ask you to disconnect the equipment from the network until the problem is
corrected or until you are sure that the equipment is not malfunctioning.
3. Facility Interface Information
In order to connect registered terminal equipment to the telephone company lines, the terminal
equipment must utilize FCC registered jacks. Standardized jacks are used for this equipment. Table 2
contains Digital Interface Code (DIC), Service Order Code (SOC), and network information for the
equipment.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
53
Download from Www.Somanuals.com. All Manuals Search And Download.
United States
Table 2
DIC, SOC, and Network Jack Information
Manufacturer
Port Identifier
Digital Interface Code Service Order Code
(DIC)
(SOC)
6.0Y
6.0Y
6.0Y
6.0Y
Network Jack
RJ-48C
T1 DFC
04DU9-BN
04DU9-DN
04DU9-1KN
04DU9-1SN
RJ-48C
RJ-48C
RJ-48C
4. Disruption of the Network
If the Cisco AS5400, Cisco AS5400HPX, or Cisco AS5400XM system disrupts the telephone network,
the telephone company can discontinue your service temporarily. If possible, the telephone company will
notify you in advance. If advance notice is not practical, they will notify you as soon as possible. You
are also informed of your right to file a complaint with the FCC.
5. Telephone Company Facility Changes
The telephone company can make changes in its facilities, equipment, operations, or procedures that can
affect the operation of your equipment. If they do, you should be notified in advance so you have an
opportunity to maintain uninterrupted telephone service.
6. Electrical Safety Advisory
While the Cisco AS5400, Cisco AS5400HPX, and Cisco AS5400XM systems are fully compliant with
FCC rules and regulations. It is recommended that an alternating current (AC) surge arrestor of the form
and capability suitable for the model purchased be installed in the AC outlet to which the Cisco AS5400,
Cisco AS5400HPX, or Cisco AS5400XM system is connected. Consult with your distributor as to the
surge protector requirements for your equipment.
7. Terminal Attachments
The Cisco AS5400, Cisco AS5400HPX, and Cisco AS5400XM systems with the interface cards
AS535-DFC-2CT1, AS535-DFC-4CT1, and AS54-DFC-8CT1 bearing labeling identification number
5B1USA-34966-DD-T complies with the Federal Communications Commission’s (“FCC”) Rules and
Regulations 47 CFR Part 68, and the Administrative Council on Terminal Attachments (“ACTA”)
adopted technical criteria: TIA/EIA/IS-968, Technical Criteria for Terminal Equipment to Prevent
Conformity. This document is also available online at:
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Canada
Canada
The channelized T3 trunk card meets Canadian requirements for T3 support as specified in CP-01
standards.
Industry Canada Compliance
The following are notices required by Industry Canada Terminal Attachment Program Certification
Procedure CP-01, Part I, Section 14.
Equipment Attachment Limitations
The Industry Canada label identifies certified equipment. This certification means that the equipment
meets certain telecommunications network protective operational and safety requirements. The
Department does not guarantee the equipment will operate to the user’s satisfaction.
Before installing the equipment, users should ensure that it is permissible to be connected to the facilities
of the local telecommunications company. The equipment must also be installed using an acceptable
method of connection. In some cases, the company’s inside wiring associated with a single line
individual service may be extended by means of a certified connector assembly (telephone extension
cord). The customer should be aware that compliance with the above conditions may not prevent
degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility
designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment
malfunctions, may give the telecommunications company cause to request the user to disconnect the
equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility,
telephone lines and internal metallic water pipe system, if present, are connected together. This
precaution may be particularly important in rural areas.
Australia
This customer equipment is to be installed and maintained by service personnel as defined by
AS/NZ3260 clause 1.2.14.3 Service Personnel. Incorrect connection of connected equipment to the
General Purpose Outlet could result in a hazardous situation.
Safety requirements are not fulfilled unless the equipment is connected to a wall socket outlet with
protective earth contact.
Europe (EU)
This apparatus complies with EN55022 Class B and EN55024 standards when used as ITE/TTE
equipment, and EN 300 386-2 (with EN55022 class B non-central office equipment) for
Telecommunications Network Equipment (TNE).
The channelized E1 trunk card meets United Kingdom (UK) requirements for E1 support as specified in
607122 standards.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
56
Download from Www.Somanuals.com. All Manuals Search And Download.
Scandinavia
E1 Dial Feature Card Independent of Host
The Cisco Systems E1 dial feature card (DFC) is a chassis-mounted processor/interface card for use
within a range of data communication (gateway and router) chassis supplied by Cisco Systems. The
Cisco Systems E1 DFC is a self-contained product that provides all of the hardware and software
necessary to allow connection of the Cisco AS5400, Cisco AS5400HPX, and Cisco AS5400XM to
structured digital leased line circuits (point to point) using CTR12 operating at 2 Mbps. The card can
also be used on an open structured leased line; however, the framing cannot be disabled. The Cisco
Systems E1 DFC is also ICTR4-compliant for use on Primary Rate ISDN circuits operating at 2 Mbps.
The Cisco Systems E1 DFC is fully transportable between compatible host chassis. The choice of each
compatible chassis has no effect on capabilities, functionality, or performance of the Cisco Systems E1
DFC.
Directives Compliance
This equipment complies with the following European Directives: 89/336/EEC (electromagnetic
compatibility), 73/23/EEC (low voltage), and 92/59/EEC (general product safety). The CE marking (see
Figure 3) signifies that this product meets the telecommunications directive 91/263/EEC.
Figure 3
CE Marking
Scandinavia
The channelized T1/E1 trunk card meets Sweden requirements for E1 support as specified in 98031130
standards.
Japan
The channelized T3 trunk card meets Japan requirements for T3 support as specified in JATE
T98-6304-0 standards.
The channelized E1 trunk card meets Japan requirements for E1 support as specified in JATE
N98-N019-0 standards.
Singapore
The channelized E1 trunk card meets Singapore requirements for E1 support as specified in
ISDN2-IPTA-AE 0345-98 and DLCN1-MBPS-AO-0344-98 standards.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
57
Download from Www.Somanuals.com. All Manuals Search And Download.
MII (China)
MII (China)
EMC Class A Notices and Warnings
This section includes the EMC Class A warnings for the Cisco AS5400XM universal gateway.
Note
Class A Notice for FCC
Modifying the equipment without Cisco’s authorization may result in the equipment no longer
complying with FCC requirements for Class A digital devices. In that event, your right to use the
equipment may be limited by FCC regulations, and you may be required to correct any interference to
radio or television communications at your own expense.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case users will be
required to correct the interference at their own expense.
Class A Notice for Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
58
Download from Www.Somanuals.com. All Manuals Search And Download.
EMC Class A Notices and Warnings
Statement 191—VCCI Class A Warning for Japan
Warning
This is a Class A product based on the standard of the Voluntary Control Council for Interference by
Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio
disturbance may arise. When such trouble occurs, the user may be required to take corrective
actions.
Statement 256—Class A Warning for Hungary
Warning
This equipment is a class A product and should be used and installed properly according to the
Hungarian EMC Class A requirements (MSZEN55022). Class A equipment is designed for typical
commercial establishments for which special conditions of installation and protection distance are
used.
Statement 294—Class A Warning for Korea
Warning
This is a Class A Device and is registered for EMC requirements for industrial use. The seller or
buyer should be aware of this. If this type was sold or purchased by mistake, it should be replaced
with a residential-use type.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
59
Download from Www.Somanuals.com. All Manuals Search And Download.
EMC Class B Notices and Warnings
EMC Class B Notices and Warnings
This section includes the EMC Class B warnings for the Cisco AS5400 and AS5400HPX universal
gateways.
Note
Class B Notice for FCC
Modifying the equipment without Cisco’s authorization may result in the equipment no longer
complying with FCC requirements for Class B digital devices. In that event, your right to use the
equipment may be limited by FCC regulations, and you may be required to correct any interference to
radio or television communications at your own expense.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Class B Notice for Canada
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Statement 295—Class B Warning for Korea
Warning
This is a Class B Device and is registered for EMC requirements for residential use. This device can
be used not only in residential areas but in all other areas.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
60
Download from Www.Somanuals.com. All Manuals Search And Download.
Related Documentation
Statement 157—VCCI Compliance for Class B Equipment
Warning
This is a Class B product based on the standard of the Voluntary Control Council for Interference from
Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a
domestic environment, it may cause radio interference. Install and use the equipment according to
the instruction manual.
Related Documentation
Use this document with the following publications:
•
•
•
•
Cisco AS5400 Universal Gateway Chassis Installation Guide
Cisco AS5400XM Universal Gateway Chassis Installation Guide
Cisco AS5350 and Cisco AS5400 Universal Gateway Card Installation Guide
Cisco AS5350XM and Cisco AS5400XM Universal Gateway Card Installation Guide
Obtaining Documentation
Cisco documentation and additional literature are available on Cisco.com. Cisco also provides several
ways to obtain technical assistance and other technical resources. These sections explain how to obtain
technical information from Cisco Systems.
Cisco.com
You can access the most current Cisco documentation at this URL:
You can access the Cisco website at this URL:
You can access international Cisco websites at this URL:
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
61
Download from Www.Somanuals.com. All Manuals Search And Download.
Obtaining Documentation
Documentation DVD
Cisco documentation and additional literature are available in a Documentation DVD package, which
may have shipped with your product. The Documentation DVD is updated regularly and may be more
current than printed documentation. The Documentation DVD package is available as a single unit.
Registered Cisco.com users (Cisco direct customers) can order a Cisco Documentation DVD (product
number DOC-DOCDVD=) from the Ordering tool or Cisco Marketplace.
Cisco Ordering tool:
Cisco Marketplace:
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
62
Download from Www.Somanuals.com. All Manuals Search And Download.
Documentation Feedback
Ordering Documentation
You can find instructions for ordering documentation at this URL:
You can order Cisco documentation in these ways:
•
Registered Cisco.com users (Cisco direct customers) can order Cisco product documentation from
the Ordering tool:
•
Nonregistered Cisco.com users can order documentation through a local account representative by
calling Cisco Systems Corporate Headquarters (California, USA) at 408 526-7208 or, elsewhere in
North America, by calling 1 800 553-NETS (6387).
Documentation Feedback
You can submit comments by using the response card (if present) behind the front cover of your
document or by writing to the following address:
Cisco Systems
Attn: Customer Document Ordering
170 West Tasman Drive
San Jose, CA 95134-9883
We appreciate your comments.
Cisco Product Security Overview
Cisco provides a free online Security Vulnerability Policy portal at this URL:
From this site, you can perform these tasks:
•
•
•
Report security vulnerabilities in Cisco products.
Obtain assistance with security incidents that involve Cisco products.
Register to receive security information from Cisco.
A current list of security advisories and notices for Cisco products is available at this URL:
If you prefer to see advisories and notices as they are updated in real time, you can access a Product
Security Incident Response Team Really Simple Syndication (PSIRT RSS) feed from this URL:
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
63
Download from Www.Somanuals.com. All Manuals Search And Download.
Obtaining Technical Assistance
Reporting Security Problems in Cisco Products
Cisco is committed to delivering secure products. We test our products internally before we release them,
and we strive to correct all vulnerabilities quickly. If you think that you might have identified a
vulnerability in a Cisco product, contact PSIRT:
•
•
Tip
We encourage you to use Pretty Good Privacy (PGP) or a compatible product to encrypt any sensitive
information that you send to Cisco. PSIRT can work from encrypted information that is compatible with
PGP versions 2.x through 8.x.
Never use a revoked or an expired encryption key. The correct public key to use in your correspondence
with PSIRT is the one that has the most recent creation date in this public key server list:
In an emergency, you can also reach PSIRT by telephone:
•
•
1 877 228-7302
1 408 525-6532
Obtaining Technical Assistance
For all customers, partners, resellers, and distributors who hold valid Cisco service contracts, Cisco
Technical Support provides 24-hour-a-day, award-winning technical assistance. The Cisco Technical
Support Website on Cisco.com features extensive online support resources. In addition, Cisco Technical
Assistance Center (TAC) engineers provide telephone support. If you do not hold a valid Cisco service
contract, contact your reseller.
Cisco Technical Support Website
The Cisco Technical Support Website provides online documents and tools for troubleshooting and
resolving technical issues with Cisco products and technologies. The website is available 24 hours a day,
365 days a year, at this URL:
Access to all tools on the Cisco Technical Support Website requires a Cisco.com user ID and password.
If you have a valid service contract but do not have a user ID or password, you can register at this URL:
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
64
Download from Www.Somanuals.com. All Manuals Search And Download.
Obtaining Technical Assistance
Note
Use the Cisco Product Identification (CPI) tool to locate your product serial number before submitting
a web or phone request for service. You can access the CPI tool from the Cisco Technical Support
Website by clicking the Tools & Resources link under Documentation & Tools. Choose Cisco Product
Identification Tool from the Alphabetical Index drop-down list, or click the Cisco Product
Identification Tool link under Alerts & RMAs. The CPI tool offers three search options: by product ID
or model name; by tree view; or for certain products, by copying and pasting show command output.
Search results show an illustration of your product with the serial number label location highlighted.
Locate the serial number label on your product and record the information before placing a service call.
Submitting a Service Request
Using the online TAC Service Request Tool is the fastest way to open S3 and S4 service requests. (S3
and S4 service requests are those in which your network is minimally impaired or for which you require
product information.) After you describe your situation, the TAC Service Request Tool provides
recommended solutions. If your issue is not resolved using the recommended resources, your service
request is assigned to a Cisco TAC engineer. The TAC Service Request Tool is located at this URL:
For S1 or S2 service requests or if you do not have Internet access, contact the Cisco TAC by telephone.
(S1 or S2 service requests are those in which your production network is down or severely degraded.)
Cisco TAC engineers are assigned immediately to S1 and S2 service requests to help keep your business
operations running smoothly.
To open a service request by telephone, use one of the following numbers:
Asia-Pacific: +61 2 8446 7411 (Australia: 1 800 805 227)
EMEA: +32 2 704 55 55
USA: 1 800 553-2447
For a complete list of Cisco TAC contacts, go to this URL:
Definitions of Service Request Severity
To ensure that all service requests are reported in a standard format, Cisco has established severity
definitions.
Severity 1 (S1)—Your network is “down,” or there is a critical impact to your business operations. You
and Cisco will commit all necessary resources around the clock to resolve the situation.
Severity 2 (S2)—Operation of an existing network is severely degraded, or significant aspects of your
business operation are negatively affected by inadequate performance of Cisco products. You and Cisco
will commit full-time resources during normal business hours to resolve the situation.
Severity 3 (S3)—Operational performance of your network is impaired, but most business operations
remain functional. You and Cisco will commit resources during normal business hours to restore service
to satisfactory levels.
Severity 4 (S4)—You require information or assistance with Cisco product capabilities, installation, or
configuration. There is little or no effect on your business operations.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
65
Download from Www.Somanuals.com. All Manuals Search And Download.
Obtaining Additional Publications and Information
Obtaining Additional Publications and Information
Information about Cisco products, technologies, and network solutions is available from various online
and printed sources.
•
Cisco Marketplace provides a variety of Cisco books, reference guides, and logo merchandise. Visit
Cisco Marketplace, the company store, at this URL:
•
Cisco Press publishes a wide range of general networking, training and certification titles. Both new
and experienced users will benefit from these publications. For current Cisco Press titles and other
information, go to Cisco Press at this URL:
•
•
Packet magazine is the Cisco Systems technical user magazine for maximizing Internet and
networking investments. Each quarter, Packet delivers coverage of the latest industry trends,
technology breakthroughs, and Cisco products and solutions, as well as network deployment and
troubleshooting tips, configuration examples, customer case studies, certification and training
information, and links to scores of in-depth online resources. You can access Packet magazine at
this URL:
iQ Magazine is the quarterly publication from Cisco Systems designed to help growing companies
learn how they can use technology to increase revenue, streamline their business, and expand
services. The publication identifies the challenges facing these companies and the technologies to
help solve them, using real-world case studies and business strategies to help readers make sound
technology investment decisions. You can access iQ Magazine at this URL:
•
•
Internet Protocol Journal is a quarterly journal published by Cisco Systems for engineering
professionals involved in designing, developing, and operating public and private internets and
intranets. You can access the Internet Protocol Journal at this URL:
World-class networking training is available from Cisco. You can view current offerings at
this URL:
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
66
Download from Www.Somanuals.com. All Manuals Search And Download.
Obtaining Additional Publications and Information
This document is to be used in conjunction with the documents listed in the “Related Documentation” section.
CCVP, the Cisco logo, and Welcome to the Human Network are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is
a service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco, the Cisco
Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity,
Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, Follow Me Browsing, FormShare, GigaDrive, HomeLink, Internet Quotient, IOS,
iPhone, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick Study, LightStream, Linksys, MeetingPlace, MGX, Networkers,
Networking Academy, Network Registrar, PIX, ProConnect, ScriptShare, SMARTnet, StackWise, The Fastest Way to Increase Your Internet Quotient,
and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a
partnership relationship between Cisco and any other company. (0711R)
Copyright © 2005 Cisco Systems, Inc. All rights reserved.
Printed in the USA on recycled paper containing 10% postconsumer waste.
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
67
Download from Www.Somanuals.com. All Manuals Search And Download.
Obtaining Additional Publications and Information
Regulatory Compliance and Safety Information for the Cisco AS5400 and Cisco AS5400XM Universal Gateways
OL-10264-01
68
Download from Www.Somanuals.com. All Manuals Search And Download.
|