FIXEDMOUNTSCANNER
Programming Manual
International Edition, Rev. A5
Download from Www.Somanuals.com. All Manuals Search And Download.
Revision History
Rev. No.
Released Date
Description
Rev. A
May 26, 2010
First Release
ꢀ Page 16
ꢀ Page 38
Add “UPC/EAN Security Level”
Rev. A1
Rev. A2
Jun. 18, 2010
Add “Immediate” parameter (option 5) to "Time Delay to Low Power Mode"
and change the default value from 5 seconds to immediate.
ꢀ Page 19,20
ꢀ Page 21
ꢀ Page 32
Add “Supplement Scan Voting” in Symbology Reading Control
Add “EAN Supplement Control”
Keyboard Layout – Add “Czech (QWERTY)”, remove “Universal”, and rename
Spain (QWERTY) to Spain (Spanish QWERTY), Latin America (QWERTY) to
Spain (Latin America, QWERTY)
Sep. 16, 2010
ꢀ Page 36
ꢀ Page 41
ꢀ Page 45
Cancel” Power On Indicator” and add “Good Read Indicator”.
“Scan Rate Control ”
Add “NG Message Output”
Rev. A3
Rev. A4
Nov 11, 2010
Mar 04, 2011
ꢀ Page 38
ꢀ Page 38
Baud Rate – Cancel Baud Rate 300/600 BPS.
Baud Rate – Revise 57.6K BPS and 115.2K BPS option code from 6.7. to 8.9.
ꢀ Page 17
ꢀ Page 39
Add ”Code 39 Security Level”
Add “NAK Retry Count”
Rev. A5
Mar 22, 2011
Add “ACK/NAK Transmission Indication”
Download from Www.Somanuals.com. All Manuals Search And Download.
© Copyright Cino Group
© Copyright PC Worth Int’l Co., Ltd
Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of
merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental
consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains
proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied,
reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written
permission of Cino. All product information and specifications shown in this document may be changed without prior notice.
Warranty
Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the
product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different
warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident
or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized
representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied
software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino’s control, such as, but
not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA
procedures to return Cino for inspection.
Regulatory
FCC part 15B
EN55022, EN55024, EN61000-3-2, EN61000-3-3
CNS13438
Industry Canada ICES-003
LED Eye Safety
IEC60825-1, EN60825-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Getting Started
Getting Familiar with Your FuzzyScan
Connect to Your Host
1
2
3
4
5
Install Your FuzzyScan
Use the Test Mode
Use Your FuzzyScan
Configure Your FuzzyScan
Bar Code Programming Manual
Programming Procedures
Host Interface Selection
Symbology Reading Control
Keyboard Interface Control
Serial Interface Control
Operation Control
7
8
12
13
32
36
39
46
Condensed DataWizard
Appendix
Symbology ID Table
Keyboard Function Code Table
ASCII Input Shortcut
Host Interface Quick Set
Operation Mode Quick Set
Option Codes
53
54
55
56
56
57
58
59
System Commands
Indications
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Familiar with Your FuzzyScan
Thank you for choosing Cino FuzzyScan FM400 Series Fixed Mount Scanner. Integrated with the innovative FuzzyScan 2.0
Imaging Technology and durable ultra-compact design, FM400 series not only provides outstanding reading performance,
but also meets various demands for both industrial and general purpose applications. This document provides a quick
reference for installation and operation purpose. The complete documentation is available at www.cino.com.tw.
FM400 Series (Front-view Model)
Power Indicator
Status Indicator
OK/NG Indicator
FM400 Series (Side-view Model)
Test Button
Scan Window
M3 Mounting Hole
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Connect to Your Host
Both RS232 and USB interfaces are available in different models of FM400 series. Each model is equipped with
corresponding connector to meet various application demands.
USB Models (FM4xx-11x)
Universal Models (FM4xx-98x)
The USB models provide a plug-and-play solution. Both
USB HID and USB COM Port Emulation interfaces are
available for user’s choice.
The universal models support RS232 and USB interfaces
with OK/NG signal outputs and external trigger input.
Pin No.
Signal
VCC
TXD
RXD
GND
---
Description
5Vdc Power Supply
Transmit Data
Receive Data
Signal Ground
---
I/O Type
Pin No.
Signal
FG
Description
Frame Ground
I/O Type
1
2
3
4
5
6
I
Case
---
I
O
I
1
2
3
4
VCC
Data -
---
USB Data -
I/O
I/O
---
---
---
O
Data + USB Data +
GND ---
4-pin Type A
Connector
15-pin D-sub HD
RTS
Request to Send
Female Connector
OK Signal Output
(3-24Vdc)
7
OK
O
8
Data + USB Data +
I/O
I
RS232 Models (FM4xx-00x)
9
Trigger External Trigger Input
The RS232 models support the standard RS232 interface
equipped a 9-pin D-sub connector with power jack for
external 5Vdc power inlet.
10
11
12
13
CTS
---
Clear to Send
---
I
---
I/O
---
Data -
Shield
USB Data -
Frame Ground
Pin No.
Signal
FG
Description
Frame Ground
I/O Type
NG Signal Output
(3-24Vdc)
Case
---
---
I
14
15
NG
O
1
2
3
4
5
6
7
8
9
---
---
Reserved ---
---
TXD
RXD
---
Transmit Data
Receive Data
---
O
---
---
---
I
GND
---
Signal Ground
---
9-pin D-sub
Female Connector
CTS
RTS
VCC
Clear to Send
Request to Send
5Vdc Power Supply
O
I
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Install Your FuzzyScan
Adjust Reading Angle
Mount Your FuzzyScan
The readability may be impacted by the specular reflection
caused by the perpendicular reading angle. To get the most
optimal reading performance, you are suggested to install
the FM400 at an approximate 15° angle to the
perpendicular line of the target barcode. However, the
reading angle and distance may vary depending on the size
and printing quality of barcodes.
There are two M3 mounting holes on the bottom of the
chassis. Please follow below procedures to mount your
scanner.
Front-view
Side-view
Prepare two appropriate M3 screws (minimal 4mm in
depth) and decide your desired mounting location.
Then adjust the two screws to accommodate 27mm
center width.
Optimize the mounting position by adjusting the
reading angle and distance. Ensure the illumination
envelop is not blocked by any external object.
Use the test mode to verify the actual reading rate. If
the reading rate is not good enough, please adjust the
reading angle and distance to get the optimum
readability.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Use the Test Mode
The FuzzyScan FM400 provides an useful test mode which is helpful for you to quickly identify the best mounting position.
Please refer to the descriptions listed below for details.
Test Button
Under normal operation, the Test Button of FM400 just acts as a normal trigger switch of hand-held scanner. You can press
the Test Button to scan the corresponding barcode commands to configure your scanner with ease.
Please note that if you press the Test button for more than 5 seconds, the FM400 will enter the test mode automatically.
Test Mode
Once determine your desired location to install the scanner, you may use the test mode to optimize the mounting position
with ease. Please follow below procedures to use the test mode.
Reading rate
100%
STATUS Indicator
Steady Green
Steady Red
OK/NG Indicator
Steady Green
Steady Green
Steady Red
Hold the Test Button over 5 seconds until the status
indicator gives one green blink, then release the button
to activate test mode. The scanner will give 2 short
beeps and the power indicator will flash blue blink per 1
second. The scanner will turn on the light source to scan
barcodes continuously before exit the test mode.
80 to 99%
50 to 79%
20 to 49%
0 to 19%
Steady Green
Steady Orange
Steady Red
Steady Orange
Steady Red
If the reading rate is not good enough, please adjust the
reading angle and distance to get the optimum
readability. If you would like to exit the test mode, please
press the Test Button once again.
Keep scanner to read the same test barcode. The
scanner will count the Good Read numbers, then output
the information of reading rate and refresh LED
indications every 100 scans. The format of output
message is listed below.
1. If the scanner is unable to read any barcode during
preset scan input time-out (default is 900ms), the
scanner will count it as a NG reading.
<
Readout data
>
:
<
Reading rate (0 to 100)
>
2. Under test mode, the OK/NG output signals will not be
performed.
At the same time, both Status and OK/NG indicators
will provide the visible reading rate information as well.
You may refer to the table listed below for details.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Use Your FuzzScan
Both FuzzyScan Barcode commands and Serial
commands are available to configure your FM400. The
FuzzyScan barcode commands are a series of proprietary
barcodes which allow you to easily configure the scanner
for most applications. Moreover, the FuzzyScan serial
commands are ideal for precise and complicated reading
control in machine-controllable environments. Please refer
to the relevant documentations for details.
OK/NG Signals
The universal models provide additional OK and NG
outputs for more precise reading control. If the scanner got
a good read, a signal will be outputted through scanner OK
pin. However, if the scanner failed to read the barcode
during a reading cycle or preset scan input time-out, a
signal will be outputted through scanner NG pin.
The OK and NG outputs are designed as NPN signal
outputs and have been preset to active low. If necessary,
you are able to change the active state of OK and NG
outputs to meet your applications.
External Trigger and Serial Trigger
The FM400 provides both external trigger and serial trigger
to activate the scanning processes. Please note that the
external trigger is available for universal models only. The
serial trigger is one of serial commands available for all
models including RS232 serial and USB COM Port
Emulation interfaces.
Operation Modes
The FuzzyScan FM400 series provides five different
operation modes, including trigger, alternative, level,
presentation and force modes to meet various application
demands.
Scan Input Time-out
The scan input time-out is a preset light source on time
available for presentation, alternative and level modes. The
scanner keeps the light source on and continues to scan
until the preset scan input time-out is up. You can adjust the
time-out duration from 100 milliseconds to 99 seconds to
meet various application demands.
Both the presentation and force modes support triggerless
operation, you don’t need to use either external trigger or
serial trigger to activate the scanning. But the trigger,
alternative and level modes have to work with external
trigger or serial trigger to scan barcode.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
is performed or the preset scan input time-out is up. Once
the light source goes off, the scanner is waiting for the next
trigger to activate scanning again.
Trigger mode
Under trigger mode, the scanner will turn on the light source
to read barcode when it receives an external trigger or a
serial trigger ON command. Once the external trigger has
been released, or the scanner gets a good read or a serial
trigger OFF command, the scanner will stop reading and
wait for the next trigger to activate scanning again.
Presentation mode
Under presentation mode, the scanner will automatically
detect the object movement in the scanner field of view.
Once the scanner detects a similar barcode image, the
scanner will turn on the light source to read barcodes until
the preset scan input time-out is up. For dark
environments, you may adjust the setting of “Presentation
Sensitivity” to increase the detection sensitivity.
Alternative mode
When the scanner receives an external trigger or a serial
trigger ON command under alternative mode, the scanner
will turn on the light source to read barcodes until the
preset scan input time-out is up. The scan input time-out
will be reset after each good read. Once the light source
goes off, the scanner is waiting for the next trigger to
activate scanning again.
Force mode
Under force mode, the scanner continues to read barcodes
without using external trigger or serial trigger. Please note
that the scanner will not stop reading until you switch into
another operation mode.
Level mode
When the scanner receives an external trigger or a serial
trigger ON command under level mode, the scanner will
turn on the light source to read barcodes until a good read
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Bar Code Programming Menu
The FuzzyScan bar code commands are specially designed
Proprietary bar code labels which allow you to set the
FuzzyScan internal programming parameters. There are
System Command, Family Code and Option Code for
programming purpose.
System Command
The System Command is the highest level bar code
command which directs FuzzyScan to perform immediate
operations, such as entering programming mode
(PROGRAM), exiting programming mode (EXIT), listing
system information (SYSLIST), recovering to factory
preset configurations (M_DEFAULT), and so on. Please
note that all system commands will take a few seconds to
complete the operations. User must wait for the
completion beeps before scanning another bar code.
Each programmable family and bar code command label is
listed on the same page with major system commands. The
detailed explanations and special programming flowchart are
printed on facing or following pages. You can read the
explanation and set the FuzzyScan concurrently.
A supplemental bar code command menu incorporates the
bar code command labels of System Command and Option
Code. As you set the FuzzyScan, open the bar code
command menu to find the option code page. You may scan
the desired family code and option code to set FuzzyScan. If
you want to change the programming family for multiple
settings, you need only turn over the programming page to
find next desired programming family.
Family Code
The Family Code is scanned to select the user desired
programming family. FuzzyScan has already provided
more than one hundred programming families to meet any
specific requirements.
Option Code
The Option Codes is a set of bar code commands
represented by “0–9”, “A–F” and finishing selection (FIN).
For most setting, you must select at least one option code
following the family code selection to set the desired
parameter for the selected programming family.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Procedures
As you scan the bar code command to select the desired
parameters, information about the final selected parameters
represented by the bar code commands are stored in the
FuzzyScan’s internal Flash Memory ASIC or non-volatile
memory. If you turn off the unit, the Flash Memory ASIC or
non-volatile memory retains all programming options. You
need not re-program the FuzzyScan if you want to keep the
existing configurations in the next power on.
If the programming family must take multiple scans
selection, cycling scan selection, or dual level selection
procedures, the family of the programming menu will be
marked with the matched representing symbol of
Programming Category (P.C.) in bold font listed in the
following table. You can easily find the bold mark in the
programming menu, and refer to their flowcharts for details.
Before setting the FuzzyScan, please also refer to the
“Beeping Indications” listed in Appendix to understand the
details of programming beeping indications. It will be very
helpful for you to know the existing status while you are
programming the FuzzyScan.
The programming procedures of FuzzyScan are designed
as simple as possible for ease of setting. Most
programming families take the Single Scan Selection
programming procedure. But several programming families
have more complex and flexible programmable options,
and you must take Multiple Scans Selection, Cycling
Scan Selection or Dual Level Selection to complete their
programming procedures. Each kind of programming
procedure is listed in the following pages for your reference.
Please give careful attention to become familiar with each
programming procedure.
Conventions of Programming Menu
Conventions
Descriptions
Factory Default Value
Programming Category
ꢁ
P.C.
SS : Signle scan selection
MS : Multiple scans selection
CS : Cycling scan selection
DS : Dual level scan selection
(
[
)
]
Necessary Option Code
Selectable Option Code
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Program & End
System List, Group & Master Default
Scan
Scan
“SYSLIST”
“PROGRAM”
FuzzyScan will list the product information and
revision number to host via selected host interface,
then issue the completion beeping.
FuzzyScan will enter programming mode,
and inhibit all non-programming functions.
Scan
Scan
“M_DEFAULT”
“END”
FuzzyScan will recover all programmable
parameters into factory preset configurations,
then issue the completion beeping.
FuzzyScan will exit programming mode, and store all
parameters in Flash Memory ASIC or non-volatile memory,
then issue the completion beeping.
Please note that the FuzzyScan will take 3-4 seconds to
store parameters in internal Flash Memory ASIC or
non-volatile memory after you scan the “END”. Please
don’t turn off the power before the completion beeping. It
may destroy all configured parameters.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Single scan selection
Multiple scans selection
Scan
Scan
Enter programming mode.
“PROGRAM”
Enter programming mode.
“
”
PROGRAM
Select one of desired
programming families.
Select one of desired
programming families.
Scan
Scan
One of Family Codes
One of
Codes
Family
1. Select one or several
option codes to select
desired parameters.
Select one option code of
desired parameter.
Scan One or
Scan
Several
Codes
Option
One of Option Codes
2. If it’s necessary, scan
“FIN” to terminate
Yes
Want to select another
programming family?
option code selection.
Yes
Repeat
Repeat
Selection
Selection
Want to select another
programming family?
No
No
Scan
Scan
Exit programming mode.
Exit programming mode.
“END”
“
”
END
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Cycling scan selection
Dual level selection
Scan
Scan
Enter programming mode.
“PROGRAM”
Enter programming mode.
“PROGRAM”
Select one of desired
programming families.
Select one of desired
programming families.
Scan
Scan
One of Family Codes
One of Family Codes
Cycling select one or
several option codes of
desired parameters as
“Single” or “Multiple”
scans selection.
Select several option codes
of desired parameters.
(1st) Scan
Scan
Several Option Codes
One of Option Codes
1. Select one or several
option codes of desired
parameters.
(2nd) Scan One or
Scan “FIN”
Several
Codes
Option
2. If it’s necessary, scan
“FIN” to terminate
Finish cycling selection.
(If necessary)
option code selection.
Yes
Yes
Repeat
Repeat
Selection
Selection
Want to select another
programming family?
Want to select another
programming family?
No
No
Scan
Scan
Exit programming mode.
Exit programming mode.
“
”
END
“
”
END
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Host Interface Selection
PROGRAM
F_DEFAULT
Family Code Selection
P.C
Parameter Selection
Option Code
MS
MS
MS
MS
Standard/TTL RS-232 peer-to-peer serial
06
09
18
19
USB Com Port Emulation
USB HID standard mode
USB HID turbo mode
Host Interface Selection
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ User Defined Symbol ID ♦
PROGRAM
F_DEFAULT
Family Code Selection
Symbol ID : 1 character
P.C
Parameter Selection
Option Code
2nd Option Code
DS
Code 128 (default=B)
UCC/EAN-128 (default=C)
UPC-A (default=A)
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
26
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
(1 character)
EAN-13 (default=F)
Codabar/NW-7 (default=D)
Code 39/Code 32 (default=G)
Code 93 (default=H)
Standard/Industrial 2 of 5 (default=I)
Interleaved 2 of 5 (default=J)
Matrix 2 of 5 (default=K)
China Postal Code (default=L)
German Postal Code (default=M)
IATA (default=O)
Code 11 (default=P)
MSI/Plessey (default=R)
UK/Plessey (default=S)
Telepen (default=T)
GS1 DataBar (default=X)
UPC-E (default=E)
EAN-8 (default=N)
Trioptic Code 39 (Default=W)
UCC Coupon Extended Code (Default=Z)
PDF417/Micro PDF417 (default=V)
Codablock F (default=Y)
Korea Post Code (default =a)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ Symbology ID Transmission ♦
PROGRAM
F_DEFAULT
Family Code Selection
Symbology ID Transmission
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
SS
SS
SS
Disable symbology ID transmission
0
1
2
3
4
5
6
Enable prefix CINO symbology ID transmission
Enable suffix CINO symbology ID transmission
Enable both prefix and suffix CINO symbology ID transmission
Enable prefix AIM symbology ID transmission
Enable suffix AIM symbology ID transmission
Enable both prefix and suffix AIM symbology ID transmission
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ Readable Bar Code Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Readable Symbology Setting
P.C
Parameter Selection
Option Code
ꢁ
SS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
Auto
00
01
02
03
04
05
06
07
47
08
38
48
58
68
09
10
11
12
13
14
15
17
18
21
Code 128 *
UPC-A *
UPC-E *
EAN-13 *
EAN-8 *
Codabar/NW-7 *
Code 39 *
Trioptic Code 39
Standard/Industrial 2 of 5
Matrix 2 of 5
Interleaved 2 of 5 *
China Postal Code
German Postal Code
Code 93 *
Code 11
MSI/Plessey
UK/Plessey
Telepen
GS1 DataBar (RSS-14) *
IATA
PDF417/Micro PDF417
Codablock F
Korea Post Code
Remember to scan “FIN” to terminate
this selection. But if you select the
“ Auto ”, FuzzyScan will terminate this
selection automatically.
ꢂ
If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add
the “Symbology ID” into the transmitted data is also helpful to identify the specific symbology.
ꢂ
ꢂ
Above symbologies marketed with * are enable as default. When you select “Auto”, the imager only read those symbologies marked with *.
When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/stop characters.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ Code 39/Code 32 Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Code 39 Family Setting
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Disable Code 39
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
ꢁ
Enable Code 39
Select Standard Code 39 as primary format
ꢁ
Select Full ASCII Code 39 as primary format
Select Code 32 (PARAF, Italian Pharmaceutical) as primary format
ꢁ
Disable start/stop symbol transmission
Enable start/stop symbol transmission
ꢁ
Disable Code 32 leading A transmission
Enable Code 32 leading A transmission
Disable MOD 43 check digit verification
Enable MOD 43 check digit verification
ꢁ
ꢁ
Disable check digit transmission
Enable check digit transmission
ꢁ
Disable Code 39 buffering
Enable Code 39 buffering
ꢁ
SS
SS
Disable Trioptic Code 39
Enable Trioptic Code 39
0
1
Trioptic Code 39 Setting
Code 39 Min. Length
Code 39 Max. Length
ꢁ
SS
MS
Default (01)
FIN
(2 digits)
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
Default (98)
98-Minimum
FIN
(2 digits)
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢂ
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ Code 39 Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Code 39 Security Level
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
Level 0
Level 1
Level 2
Level 3
0
1
2
3
ꢁ
ꢂ
Code 39 Security Level
The scanner offers four levels of decode security for Code39 bar codes:
Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.
Level 1: If you are experiencing misread of poorly-printed or out-of-spec. bar codes in level 2, please select level 1.
Level 2: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” Code39 bar codes.
Level 3: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 3. This is the most aggressive setting and may increase the misread.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ Codabar/NW-7 Setting ♦
PROGRAM
Family Code Selection
Codabar Setting
F_DEFAULT
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Disable Codabar
Enable Codabar
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
ꢁ
ꢁ
Select Codabar standard format
Select Codabar ABC format
Select Codabar CLSI format
Select Codabar CX format
ꢁ
Disable start/stop symbol transmission
Enable ABCD/ABCD start/stop symbol transmission
Enable abcd/abcd start/stop symbol transmission
Enable ABCD/TN*E start/stop symbol transmission
Enable abcd/tn*e start/stop symbol transmission
ꢁ
Disable check digit verification
Enable check digit verification
ꢁ
Disable check digit transmission
Enable check digit transmission
ꢁ
SS
MS
Default (04)
FIN
(2 digits)
Codabar Min. Length
Codabar Max. Length
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
Default (98)
98-Minimum
FIN
(2 digits)
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ UPC-A & UPC-E Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
UPC Family Setting
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Disable UPC-A
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
ꢁ
ꢁ
Enable UPC-A
Disable UPC-E
Enable UPC-E
Disable UPC-E expansion
Enable UPC-E expansion
ꢁ
ꢁ
ꢁ
Disable UPC standardization
Enable UPC standardization
Disable UPC numeric system
Enable UPC numeric system
Disable UPC-A check digit transmission
Enable UPC-A check digit transmission
Disable UPC-E check digit transmission
Enable UPC-E check digit transmission
ꢁ
ꢁ
ꢁ
Disable UPC “leading 1” portion
Enable UPC “leading 1” portion
ꢂ
When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric
system, UPC-A check digit transmission.
ꢂ
ꢂ
ꢂ
UPC-E & EAN-8 Expansion
UPC-A Standardization
UPC Lead 1 Numeric System
: Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.
: Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.
: Enable to read UPC leading with the 1 numeric system, you must enable this option.
WPC Selection
(UPC/EAN/CAN)
Disable
Check Digit
Disable
Numeric System
With 2-digit
Addendum
With 5-digit
Addendum
Enable
Standardization
Enable
Expansion
Basic Length
UPC-A
UPC-E
EAN-13
EAN-8
12
8
13
8
- 1
- 1
- 1
- 1
- 1
- 1
NC
NC
+ 2
+ 2
+ 2
+ 2
+ 5
+ 5
+ 5
+ 5
+ 1
+ 1
NC
NC
0
+ 4
0
+ 5
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ UPC-A & UPC-E Setting , Supplement Scan Voting♦
PROGRAM
F_DEFAULT
Family Code Selection
UPC Supplement Setting
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
SS
SS
SS
SS
Select UPC without supplement digits
0
1
2
3
4
5
6
7
Select UPC with only 2 supplement digits
Select UPC with only 5 supplement digits
Select UPC with 2/5 supplement digits
ꢁ
Disable force supplement digits output
Enable force supplement digits output
ꢁ
UPC Family Addenda Separator Off
UPC Family Addenda Separator On
SS
SS
Level 0
Level 1
Level 2
0
1
UPC/EAN Security Level
Supplement Scan Voting
ꢁ
SS
2
Only available for UPC-A & EAN-13
SS
SS
SS
SS
SS
SS
SS
None
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8
Level 9
Level 10
Level 11
Level 12
Level 13
0
1
2
3
4
5
6
7
8
9
A
B
C
D
ꢁ
ꢂ
UPC/EAN Security Level
The scanner offers three levels of decode security for UPC/EAN bar codes:
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this
security level may significantly impair the decoding ability of the scanner.
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may
increase the misread.
ꢂ
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding
a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5
supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,
low contrast or damage barcode labels.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ EAN Setting , Supplement , Supplement Scan Voting♦
PROGRAM
Family Code Selection
EAN Setting
F_DEFAULT
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Disable EAN-13
Enable EAN-13
Disable EAN-8
0
1
2
3
4
5
6
7
8
9
A
B
ꢁ
ꢁ
Enable EAN-8
ꢁ
Disable EAN-8 expansion
Enable EAN-8 expansion
Disable EAN-13 check digit transmission
Enable EAN-13 check digit transmission
Disable EAN-8 check digit transmission
ꢁ
ꢁ
Enable EAN-8 check digit transmission
ꢁ
Disable ISBN/ISSN Conversion reading check
Enable ISBN/ISSN Conversion reading check
ꢁ
SS
SS
SS
SS
SS
SS
SS
SS
Select EAN without supplement digits
0
1
2
3
4
5
6
7
EAN Supplement Setting
Select EAN with only 2 supplement digits
Select EAN with only 5 supplement digits
Select EAN with 2/5 supplement digits
ꢁ
Disable force supplement digits output
Enable force supplement digits output
ꢁ
EAN Addenda Separator Off
EAN Addenda Separator On
SS
SS
SS
SS
SS
SS
SS
None
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8
Level 9
Level 10
Level 11
Level 12
Level 13
0
1
2
3
4
5
6
7
8
9
A
B
C
D
Supplement Scan Voting
ꢁ
ꢂ
The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding
a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5
supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,
low contrast or damage barcode labels.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ UPC/EAN Security Level Setting ,
EAN Supplement Control♦
PROGRAM
F_DEFAULT
Family Code Selection
UPC/EAN Security Level
P.C
Parameter Selection
Option Code
SS
SS
Level 0
Level 1
Level 2
0
1
ꢁ
SS
2
Only available for UPC-A & EAN-13
ꢁ
SS
SS
SS
SS
SS
SS
SS
SS
Disable all specific prefix supplement digital output
Enable all specific prefix supplement digital output
Enable 491 Supplement Digit Output
Enable 978/979 Supplement Digit Output
Enable 977 Supplement Digit Output
Enable 378/379 Supplement Digit Output
Enable 414/419 Supplement Digit Output
Enable 434/439 Supplement Digit Output
0
1
2
3
4
5
6
7
EAN Supplement Control
ꢂ
UPC/EAN Security Level
The scanner offers three levels of decode security for UPC/EAN bar codes:
Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this
security level may significantly impair the decoding ability of the scanner.
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may
increase the misread.
ꢂ
EAN Supplement Control
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5 or 2/5 supplement
digits bar codes starting with 491 prefix. The EAN without supplement digit will not be transmitted.
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable the other except 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5, or 2/5
supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ UCC Coupon Extended Code Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
UCC Coupon Extended Code
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
Disable UCC Coupon Extended Code
Enable UCC Coupon Extended Code
0
1
ꢂ
UCC Coupon Extended Code
When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and UCC/EAN-128
Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ IATA & Interleaved 2 of 5 Setting ♦
PROGRAM
Family Code Selection
IATA Setting
F_DEFAULT
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Disable IATA
Enable IATA
0
1
2
3
4
5
6
7
8
9
A
B
C
ꢁ
Select 15-digit fixed length IATA checking
Select variable length IATA
ꢁ
Disable check digit verification
Enable check digit automatic verification
Enable S/N checking digit verification only
Enable CPN checking digit verification only
Enable CPN, Airline and S/N check digit verification
ꢁ
Disable check digit transmission
Enable check digit transmission
ꢁ
Disable start/stop symbol transmission
Enable start/stop symbol transmission
SS
SS
SS
SS
SS
SS
SS
SS
SS
Disable Interleaved 2 of 5
0
1
2
3
4
5
6
7
8
Interleaved 2 of 5 Setting
ꢁ
Enable Interleaved 2 of 5
Select Interleaved 2 of 5 as primary format
Select German Postal Code as primary format
ꢁ
ꢁ
No check character
Validate USS check digit
Validate OPCC check digit
Disable check digit transmission
Enable check digit transmission
ꢁ
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ Code 25 Family Setting ♦
PROGRAM
Family Code Selection
Code 25 Setting
F_DEFAULT
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Disable Standard/Industrial 2 of 5
Enable Standard/Industrial 2 of 5
0
1
2
3
4
5
6
7
8
9
ꢁ
Disable Matrix 2 of 5
Enable Matrix 2 of 5
ꢁ
Disable China Postal Code
Enable China Postal Code
ꢁ
Disable check digit verification
Enable check digit verification
ꢁ
Disable check digit transmission
Enable check digit transmission
ꢁ
SS
MS
Default (04)
FIN
(2 digits)
Code 25 Family Min. Length
Code 25 Family Max. Length
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
Default (98)
98-Minimum
FIN
(2 digits)
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢂ
For Code25 setting, we recommend you to select only one type of Code 25 or set the maximum/minimum bar code length. To decode all types of Code 25 or to variable
length of Code 25 will increase the possibility of reading error.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ Code 11 & Code 93 Setting ♦
PROGRAM
Family Code Selection
Code 11 Setting
F_DEFAULT
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
SS
SS
SS
Disable Code 11
Enable Code 11
0
1
2
3
4
5
6
ꢁ
Disable check digit verification
Select 1-check digit verification
Select 2-check digit verification
ꢁ
Disable check digit transmission
Enable check digit transmission
ꢁ
SS
MS
Default (04)
FIN
(2 digits)
Code 11 Min. Length
Code 11 Max. Length
Code 93 Setting
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
Default (98)
98-Minimum
FIN
(2 digits)
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
SS
SS
SS
SS
Disable Code 93
Enable Code 93
Disable check digit transmission
Enable check digit transmission
0
1
2
3
ꢁ
ꢁ
ꢁ
SS
MS
Default (01)
FIN
(2 digits)
Code 93 Min. Length
Code 93 Max. Length
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
Default (98)
98-Minimum
FIN
(2 digits)
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ MSI/Plessey Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
MSI/Plessey Setting
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
SS
SS
SS
Disable MSI/Plessy
Enable MSI/Plessy
0
1
2
3
4
5
6
ꢁ
Select MOD 10 check digit
Select MOD 10-10 check digit
Select MOD 11-10 check digit
Disable check digit transmission
Enable check digit transmission
ꢁ
ꢁ
SS
MS
Default (04)
FIN
(2 digits)
MSI/Plessey Min. Length
MSI/Plessey Max. Length
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
Default (98)
98-Minimum
FIN
(2 digits)
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ Code 128 & UCC/EAN 128 Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Code 128/EAN-128 Setting
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
SS
SS
Disable Code 128 and UCC/EAN-128
0
1
2
3
4
5
ꢁ
Enable Code 128 and UCC/EAN-128
ꢁ
Disable function code conversion
Enable function code conversion
ꢁ
ISBT Concatenation Off
ISBT Concatenation On
ꢁ
SS
MS
Default (01)
FIN
(2 digits)
Code 128/EAN-128 Min. Length
Code 128/EAN-128 Max. Length
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
Default (98)
98-Minimum
FIN
(2 digits)
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ UK/Plessey Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
UK/Plessey Setting
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
SS
SS
SS
SS
Disable UK/Plessey
Enable UK/Plessey
0
1
2
3
4
5
6
7
ꢁ
Select UK/Plessey Standard Format
Select UK/Plessey CLSI Format
ꢁ
Disable Convert X to A-F
Enable Convert X to A-F
ꢁ
Disable check digit transmission
Enable check digit transmission
ꢁ
SS
MS
Default (04)
FIN
(2 digits)
UK/Plessey Min. Length
UK/Plessey Max. Length
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
Default (98)
98-Minimum
FIN
(2 digits)
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ Telepen Setting ♦
PROGRAM
Family Code Selection
Telepen Setting
F_DEFAULT
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
SS
SS
Disable Telepen
Enable Telepen
0
1
2
3
4
5
ꢁ
Select Telepen Numeric mode
Select Telepen Full ASCII mode
Disable check digit transmission
Enable check digit transmission
ꢁ
ꢁ
SS
MS
Default (04)
FIN
(2 digits)
Telepen Min. Length
Telepen Max. Length
01-Maximum
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
Default (98)
98-Minimum
FIN
(2 digits)
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ GS1 DataBar Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
GS1 DataBar Setting
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
SS
SS
Disable GS1 DataBar (RSS-14)
0
1
2
3
4
5
ꢁ
Enable GS1 DataBar (RSS-14)
Disable GS1 DataBar Limited
ꢁ
Enable GS1 DataBar Limited
Disable GS1 DataBar Expanded
Enable GS1 DataBar Expanded
ꢁ
ꢁ
SS
MS
Default (04)
FIN
(2 digits)
GS1 DataBar Min. Length
GS1 DataBar Max. Length
01-Maximum
Only available for Expanded GS1 Databar.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
Default (74)
74-Minimum
FIN
(2 digits)
Only available for Expanded GS1 Databar.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology Reading Control
♦ Linear-stacked & Korea Post Code Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Composite Codes Setting
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
Disable composite codes
Enable composite codes
0
1
2
3
ꢁ
UPC Composite Mode: UPC never linked
UPC Composite Mode: UPC always linked
SS
SS
SS
SS
Disable PDF417
Enable PDF417
Disable MicroPDF417
Enable MicroPDF417
0
1
2
3
PDF417/MicroPDF417 Setting
Codablock F Setting
ꢁ
ꢁ
ꢁ
SS
SS
Disable
Enable
0
1
ꢁ
SS
SS
Disable
Enable
0
1
Korea Post Code Setting
Length fixed in 6 characters.
ꢂ
Composite Codes Setting
If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected.
If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyboard Interface Control
♦ Keyboard Layout (Language) Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Keyboard Layout
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
USA (QWERTY)
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
France (AZERTY)
Germany (QWERTZ)
United Kingdom - UK (QWERTY)
Canadian French (QWERTY)
Spain (Spanish, QWERTY)
Sweden/Finland (QWERTY)
Portugal (QWERTY)
Norway (QWERTY)
Spain (Latin America, QWERTY)
Italy (QWERTY)
Netherlands (QWERTY)
Denmark (QWERTY)
Belgium (AZERTY)
Switzerland-Germany (QWERTY)
Iceland (QWERTY)
Japan (DOS/V)
Czech (QWERTY)
ꢂ
ꢂ
ꢂ
Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as preamble or postamble.
To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first.
Keyboard Interface Message String :
Preamble
Data Length
2-3 digits
Prefix Symbol ID
1 or 2 characters
Scanned Data
Suffix Symbol ID
1 or 2 characters
Postamble
Record Suffix
1 character
1-15 characters
Variable length
1-15 characters
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyboard Interface Control
♦ Record Suffix, Preamble, Postamble & Caps Lock ♦
PROGRAM
Family Code Selection
Record Suffix
F_DEFAULT
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
SS
SS
None
RETURN
TAB
0
1
2
3
4
ꢁ
SPACE
ENTER (Numeric Key Pad)
User defined character (1 character)
5, (00-7F)
ꢁ
SS
MS
None
FIN
[00-7F], [FIN]
Preamble
Postamble
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
ꢁ
SS
MS
None
FIN
[00-7F], [FIN]
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
ꢁ
SS
SS
SS
“Caps Lock Off” State
“Caps Lock On” State
0
1
2
Caps Lock Control
Caps Lock Release Control
Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)
ꢁ
SS
SS
“Caps Lock On, Caps Off”
“Caps Lock On, Shift Off”
0
1
ꢂ
ꢂ
The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines.
While selecting the other host interfaces, these selections don’t perform the above functions for you.
Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then FuzzyScan will
perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect”, FuzzyScan will perform special transmission
handshaking without changing the status of Caps Lock switch.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyboard Interface Control
♦ Delay Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Intermessage Delay
P.C
Parameter Selection
Option Code
ꢁ
SS
MS
None
FIN
(2 digits)
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
None
FIN
(2 digits)
Intercharacter Delay
Interfunction Delay
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
None
FIN
(2 digits)
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢂ
ꢂ
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data
transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)
various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two
parameters.
ꢂ
Interfunction Delay is a time delay between the transmission of each segment of the message string.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyboard Interface Control
♦ Emulation Setting & Upper/Lower Case Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Function Key Emulation
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
Enable ASCII 00-31 code as keyboard function code output
Ctrl-Output
0
1
Refer to Appendix – Keyboard Function Code Table for details.
ꢁ
SS
SS
Disable key pad emulation
0
1
Key Pad Emulation
Upper/Lower Case
Enable numeric output as key pad (Num Lock On) output
ꢁ
SS
SS
SS
SS
Normal case (neglect the upper/lower case control)
0
1
2
3
Inverse case (change all characters output to inverse case)
Upper case (force all characters output as upper case)
Lower case (force all characters output as lower case)
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Interface Control
♦ Record Suffix, Preamble, Postamble Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
STX/ETX Control
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
Disable STX/ETX transmission
Enable STX/ETX transmission
0
1
STX/ETX are two characters used to indicate the starting and ending of the total
data frame transmitted via serial interface.
SS
SS
SS
SS
SS
SS
MS
None
CR (0DH)
LF (0AH)
CRLF (0D0AH)
TAB (09H)
0
1
2
3
4
5
Record Suffix
ꢁ
SPACE (20H)
User defined character (1 character)
6, (00-7F)
ꢁ
SS
MS
None
FIN
[00-7F], [FIN]
Preamble
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
ꢁ
SS
MS
None
FIN
[00-7F], [FIN]
Postamble
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
ꢂ
Serial Interface Message String (RS232, USB COM) :
STX
Preamble
Data Length
2-3 digits
Prefix Symbol ID Scanned Data
Suffix Symbol ID
Postamble
ETX
Record Suffix
1 character
1 character
1-15 characters
1 or 2 characters Variable length 1 or 2 characters 1-15 characters
1 character
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Interface Control
♦ Delay Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Intermessage Delay
P.C
Parameter Selection
Option Code
ꢁ
SS
MS
None
FIN
(2 digits)
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
None
FIN
(2 digits)
Intercharacter Delay
Interfunction Delay
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢁ
SS
MS
None
FIN
(2 digits)
1-99 (x5) msec.
Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate
this selection automatically.
ꢂ
ꢂ
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.
Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data
transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)
various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two
parameters.
ꢂ
Interfunction Delay is a time delay between the transmission of each segment of the message string.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Interface Control
♦ Protocol, ACK/NAK Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Handshaking Protocol
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
None (free running mode)
0
1
2
3
RTS/CTS (hardware handshaking)
ACK/NAK (software handshaking)
Xon/Xoff (software handshaking)
ꢁ
SS
SS
3 times
FIN
(3 digits)
NAK Retry Count
0~255 times
SS
SS
Disable
Enable
0
1
ACK/NAK Transmission Indication
ꢁ
ꢂ
USB COM doesn’t support RTS/CTS handshaking protocol.
ꢂ
When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after
each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK.
ꢂ
NAK Retry Count
After transmitting data, the scanner expects a NAK response from the host up to the preset “Serial Response Time-out”. If the scanner doesn’t get a response, the scanner
will issue an error indication and discard the data. When a NAK is received, the scanner transmits the same data again and waits for either an ACK or NAK. The scanner
issues an error indication and discards the data under following two conditions:
1) After preset NAK retry counts is received within the preset serial response time-out.
2) If the preset time-out is up but the preset NAK retry counts haven’t come to the end.
The default retry counts are three times. If you program “0 time”, the scanner won’t resend the data to the host when the scanner receives a NAK. The scanner will discard
the data. If you program “255 times”, the scanner can receive unlimited NAKs from the host within the pre-set serial response time-out.
This function is not available for batch mode. When you enable this function in on-line mode, the out-of-range function will be disable automatically.
ꢂ
ACK/NAK Transmission Indication:
Disable: There’s neither LED nor beeping indication for this setting.
Enable: There’s a specific LED and beeping indication for this setting.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Interface Control
♦Time Out Setting, Baud Rate, Data Frame♦
PROGRAM
F_DEFAULT
Family Code Selection
Serial Response Time-out
P.C
Parameter Selection
Option Code
SS
SS
SS
MS
None
200 mseconds
500 mseconds
1 second
2 seconds
5 seconds
User defined value (seconds)
0
1
2
3
4
5
ꢁ
6, (2 digits)
SS
SS
SS
SS
38.4K BPS
19.2K BPS
2400 BPS
1200 BPS
57.6K BPS
115.2K BPS
0
1
2
3
4
5
8
9
Baud Rate (BPS)
Data Frame
ꢁ
9600 BPS
4800 BPS
ꢁ
SS
SS
SS
SS
SS
SS
SS
SS
8, None, 1
8, Odd, 1
8, Even, 1
8, Space, 1
8, Mark, 1
8, None, 2
7, Odd, 1
7, Space, 1
7, Mark, 1
7, None, 2
7, Odd, 2
7, Even, 2
7, Space, 2
7, Mark, 2
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
7, Even, 1
ꢂ
ꢂ
When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data
communication. This option is very helpful to ensure the reliability of data communication.
The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Control
♦ Operation Mode Setting ♦
PROGRAM
Family Code Selection
Operation Mode
F_DEFAULT
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
SS
Trigger mode
1
2
3
5
8
Presentation mode
Alternative mode
Force mode
Level mode
ꢂ
ꢂ
ꢂ
Trigger Mode (External Triggering) When the scanner receives an external trigger or a serial trigger ON command under trigger mode, the scanner will turn on the light
source to read barcode until gets a good read, a serial trigger OFF command or a release of external trigger. Once the light source goes off, the scanner is waiting for the
next trigger to activate scanning again.
Presentation Mode (Auto Detection) Under presentation mode, the scanner will automatically detect the object movement in the scanner field of view. Once the scanner
detected a similar barcode image, the scanner will turn on the light source to read barcodes until the preset scan input time-out is up. For dark environments, you may
adjust the setting of “Presentation Sensitivity” to increase the detection sensitivity
Alternative Mode (Periodic Power Off) When the scanner receives an external trigger or a serial trigger ON command under alternative mode, the scanner will turn on the
light source to read barcodes until the preset scan input time-out is up. The scan input time-out will be reset after each good read. Once the light source goes off, the
scanner is waiting for the next trigger to activate scanning again.
ꢂ
ꢂ
Force Mode (Continued Power On) Under force mode, the scanner continues to read barcodes without using external trigger or serial trigger. Please note that the scanner
will not stop reading until you switch into another operation mode.
Level Mode (Auto Power Off) When the scanner receives an external trigger or a serial trigger ON command under level mode, the scanner will turn on the light source to
read barcodes until a good read is performed or the preset scan input time-out is up. Once the light source goes off, the scanner is waiting for the next trigger to activate
scanning again.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Control
♦ Buzzer, Indicator, Inverse Reading♦
PROGRAM
F_DEFAULT
Family Code Selection
Buzzer Tone Adjust
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
SS
SS
SS
Buzzer tone – mute
Buzzer tone – low
Buzzer tone – medium
Buzzer tone – high
0
1
2
3
4
5
6
ꢁ
Buzzer tone - extremely high
ꢁ
Power-on beep
No power-on beep
SS
SS
Disable (LED off)
0
1
2
Power On Indicator
Good Read Indicator
Inverse Reading
ꢁ
LED steady on
LED flash
SS
SS
Disable
0
1
ꢁ
ꢁ
Enable
SS
SS
Disable
Enable
0
1
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Control
♦Dollar Sign, Redundancy, Scan Rate Control ♦
PROGRAM
F_DEFAULT
Family Code Selection
Dollar Sign Control
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
SS
Dollar sign output as “ $ “
0
1
2
3
4
Dollar sign output as “
“
Dollar sign output as “ € “
Dollar sign output as “ £ “
Dollar sign output as “ ¢ “
SS
SS
SS
SS
SS
SS
None
0
1
2
3
4
5
Redundancy
ꢁ
Level 1
Level 2
Level 3
Level 4
Level 5
To prevent potential miss reading.
ꢁ
SS
SS
Dynamic
Fixed
0
1
Scan Rate Control
ꢂ
ꢂ
The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted.
Scan Rate Control: The scanner will have better motion tolerance when you select “Fixed” scan rate. It’s suitable for application which needs higher motion tolerance on
the move. But this may impact to the reading distance.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Control
♦ Delay Setting ♦
PROGRAM
Family Code Selection
Reread Delay
F_DEFAULT
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
SS
SS
Disable
0
1
2
3
4
5
ꢁ
Immediate time out
Short time out
Medium time out
Long time out
Force verification
(DoubleSanVerification)
ꢁ
SS
SS
SS
SS
SS
SS
SS
None
0
1
2
3
4
5
6
Good Read Delay
200 msec.
500 msec.
1 sec.
1.5 sec.
2 sec.
3 sec.
ꢂ
ꢂ
The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification
will not allow reading of the same bar code twice.
This Good Read Delay is the minimum amount of time before the imager can read another bar code.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Control
♦ Time-out and Duration Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Scan Input Time-out
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
SS
MS
100 msec.
200 msec.
300 msec.
400 msec.
500 msec.
600 msec.
700 msec.
800 msec.
0
1
2
3
4
5
6
7
8
ꢁ
900 msec.
User define: 1-99 sec.
9, (2digits)
ꢁ
Medium
SS
SS
SS
SS
SS
Short
0
1
2
3
4
Hands Free Time-out
Good Read Duration
Long
Extremely long
Disable
SS
SS
SS
SS
SS
Short
0
1
2
3
4
ꢁ
Medium
Long
Extremely long
Extremely short
ꢂ
ꢂ
The Scan Input Time-out is a preset light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on till the
preset light source on time is up. You can adjust this parameter to meet your own application requirement.
The presentation mode and force mode will be automatically changed to manual trigger mode when you activate the trigger. You can remain the scanner in manual trigger
mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there’s no any trigger operation), the imager will revert to the original presentation or force
mode.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Control
♦ Presentation Scanning Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Presentation Sensitivity
P.C
Parameter Selection
Option Code
SS
SS
SS
SS
SS
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
0
1
2
3
4
5
6
ꢁ
ꢂ
The presentation sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting
the barcode.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation Control
♦ OK/NG Signal and Beeping Control ♦
PROGRAM
F_DEFAULT
Family Code Selection
OK/NG Signal Active State
P.C
Parameter Selection
Option Code
ꢁ
SS
SS
SS
SS
OK low/NG low
0
1
2
3
OK low/NG high
OK high/NG low
OK high/NG high
SS
SS
SS
SS
Disable OK and NG output
Enable NG output
Enable OK output
0
1
2
3
OK/NG Signal Output Control
ꢁ
Enable OK and NG output
SS None
SS Message “NG”
0
1
NG Message Output
SS User defined message (1~15 characters)
2, 00- 7F
Maximum 15-character input ; scan “FIN” to terminate this section.
SS
SS
SS
SS
SS
MS
10 msec.
20 msec.
30 msec.
40 msec.
50 msec.
60 msec.
70 msec.
80 msec.
90 msec.
100 msec.
0
1
2
3
4
5
6
7
8
OK/NG Signal Duration
ꢁ
9
User define: 1-99 (x50) msec.
A, (2 digits)
SS
SS
SS
SS
Disable OK and NG beep
Enable OK and NG beep
Enable OK beep and disable NG beep
Enable NG beep and disable OK beep
0
1
2
3
OK/NG Beeping Control
ꢁ
47
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢂ
ꢂ
ꢂ
The OK/NG Signal Active State can control the logic level in digit circuits design, you can adjust the active-high or active-low state for OK and NG signal outputs. The OK
and NG signals are NPN outputs.
The OK/NG Signal Output Control can control the OK/NG signal outputs and OK/NG indications of the scanner. If you disable OK or NG signal output, the scanner OK or
NG indication will be disabled.
The OK/NG Signal Duration can control the OK/NG signal duration and OK/NG indication duration of the scanner.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Condensed DataWizard
♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦
PROGRAM
Family Code Selection
Preamble
F_DEFAULT
P.C
Parameter Selection
Option Code
ꢁ
SS
MS
None
FIN
[00-7F], [FIN]
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
ꢁ
SS
MS
None
FIN
[00-7F], [FIN]
Postamble
1-15 characters
Maximum 15-character input; scan “FIN” to terminate this selection.
ꢁ
SS
SS
Disable
0
1
Data Length Transmission
Symbology ID Transmission
Enable 2 digits data length transmission
If data length exceeds 99, 3-digit data length will be transmitted.
ꢁ
SS
SS
SS
SS
SS
SS
SS
Disable symbology ID transmission
Enable prefix symbology ID transmission
Enable suffix symbology ID transmission
Enable both prefix and suffix symbology ID transmission
Enable prefix AIM symbology ID transmission
Enable suffix AIM symbology ID transmission
Enable both prefix and suffix AIM symbology ID transmission
0
1
2
3
4
5
6
ꢂ
DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard,
you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help
you to arrange the transmission of scanned data to any specific format without software modification.
ꢂ
ꢂ
Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool. Through the PowerTool, all settings and configurations can be done
on-screen, under Windows 95/98/NT/2000/XP environment.
A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with
ease.
ꢂ
ꢂ
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Condensed DataWizard
♦ Data Formatter Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Formatter Control
P.C
Parameter Selection
Option Code
2nd Option Code
ꢁ
SS
MS
MS
Disable
FIN
(2 digits)
00
Select one bar code symbology
Select all bar code symbologies
automatic termination
automatic termination
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
1st Insertion
2nd Insertion
3rd Insertion
4th Insertion
[1-3 characters], [FIN]
[1-3 characters], [FIN]
[1-3 characters], [FIN]
2-digits identified position; max. 3 insertion characters
position
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
2-digits identified position; max. 3 insertion characters
position
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
2-digits identified position; max. 3 insertion characters
position
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
[1-3 characters], [FIN]
2-digits identified position; max. 3 insertion characters
position
ꢂ
ꢂ
The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code
symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position.
While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.
All of the above programmable parameters perform the same function depending on your setting.
ꢂ
ꢂ
Regarding the “Bar Code Selection” and “Position Calculation” of data formatter, please refer to page 49 for details.
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Condensed DataWizard
♦ Data Verifier Setting ♦
PROGRAM
Family Code Selection
Verifier Control
F_DEFAULT
P.C
Parameter Selection
Option Code
2nd Option Code
ꢁ
SS
MS
MS
Disable
FIN
(2 digits)
00
Select one bar code symbology
Select all bar code symbologies
automatic termination
automatic termination
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
Identified Data Length
1st Identified Character
2nd Identified Character
3rd Identified Character
Determine the identified data length for verification.
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
[00-7F]
[00-7F]
[00-7F]
2-digits checking position; 1 identified character
position
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
2-digits checking position; 1 identified character
position
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
2-digits checking position; 1 identified character
position
ꢂ
ꢂ
The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter.
All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the
FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data.
ꢂ
ꢂ
ꢂ
The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.
Regarding the “Bar Code Selection” and “Position Calculation” of Data Verifier, please refer to page 49 for details.
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Condensed DataWizard
♦ Data Replacer Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Replacer Control
P.C
Parameter Selection
Option Code
2nd Option Code
ꢁ
SS
MS
MS
Disable
FIN
(2 digits)
00
Select one bar code symbology
Select all bar code symbologies
automatic termination
automatic termination
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
1st Replacement
2nd Replacement
3rd Replacement
[00-7F]
[00-7F]
[00-7F]
2-digits identified position; 1 replacement character
position
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
2-digits identified position; 1 replacement character
position
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
2-digits identified position; 1 replacement character
position
ꢂ
ꢂ
The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code
symbologies for replacer control, and provides Multiple Position Replacement in the identified position.
All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it
arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.
ꢂ
ꢂ
Regarding the “Bar Code Selection” and “Position Calculation” of Data Replacer, please refer to page 49 for details.
Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Condensed DataWizard
♦ Data Organizer Setting ♦
PROGRAM
F_DEFAULT
Family Code Selection
Organizer Control
P.C
Parameter Selection
Option Code
2nd Option Code
ꢁ
SS
MS
MS
Disable
FIN
(2 digits)
00
Select one bar code symbology
Select all bar code symbologies
automatic termination
automatic termination
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
1st Organization
2nd Organization
ꢁ
0 (Forward)
1 (Backward)
2-digits identified position;
Forward/backward data transmission setting
position
direction
ꢁ
SS
DS
Disable
Enable
FIN
(2 digits)
ꢁ
0 (Forward)
1 (Backward)
2-digits identified position;
Forward/backward data transmission setting
position
direction
ꢁ
SS
DS
Transmitted data excluded the data of identified position
Transmitted data included the data of identified position
0
1
Include/Exclude Control
ꢂ
ꢂ
The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code
symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data
including or excluding the data of identification position. Please refer to the application example listed in page 37 for details.
While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record
Suffix.
ꢂ
ꢂ
Regarding the “Bar Code Selection” and “Position Calculation” of Data Organizer, please refer to page 49 for details.
Please note that all “Character” input should be referred to the ASCII/HEX Table.
53
Download from Www.Somanuals.com. All Manuals Search And Download.
[Data Verifier, Data Replacer, Data Organizer]
Select a Bar Code Symbology
If there is a 11-character data string, please refer to the
following to calculate the actual position for identification.
You can select one or all types of bar code symbologies to
use Condensed DataWizard for advanced transmission
arrangement. If you scan “00” to select all types, the
FuzzyScan will arrange all incoming data to meet your
pre-defined format. If you want to select only one type bar
code, please select one of the option code listed below.
X
X
X
X
X
X
X
X
X
X
X
00
01
02
03
04
05
06
07
08
09
10
Application Example
Code 128 : 01
EAN-8 : 05
Code 93 : 09
If your bar code label is a 16-digit Interleaved 2 of 5 which
includes the information of 6-digit date code, 6-digit serial
number and 4-digit unit price, you want the FuzzyScan do
the following for you without software modification:
UCC/EAN 128 : 31
UPC-A : 02
EAN-8 with 2 supple : 35
EAN-8 with 5 supple.: 45
Codabar/NW-7 : 06
Code 39 : 07
Code 11 : 10
MSI/Plessey : 11
UK/Plessey : 12
Telepen : 13
UPC-A with 2 supple.: 32
UPC-A with 5 supple.: 42
UPC-E : 03
Code 32 : 37
GS1 Data Bar : 14
IATA : 15
ꢂ Apply only Interleaved 2 of 5 to the condensed
UPC-E with 2 supple.: 33
UPC-E with 5 supple.: 43
EAN-13 : 04
Trioptic Code 39: 47
Matrix 2 of 5 : 38
Interleaved 2 of 5 : 48
DataWizard.
Coupon Code : 16
PDF417/MicroPDF417: 22
Codablock: 23
ꢂ Check bar code is actually with 16-digit length.
EAN-13 with 2 supple. : 34 China Postal Code : 58
EAN-13 with 5 supple. : 44 German Postal Code : 68
ꢂ Allow bar code output whose date code is leading with
Korea Post Code: 26
“9”.
Position Calculation
[Data Formatter]
ꢂ Three outputs with “TAB” suffix.
ꢂ The date code output should skip “9” and replaced it by
“A”.
If there is a 5-character input data string, refer to the following
to calculate the actual position for insertion:
ꢂ The serial number output should be led with “SN”.
X
X
X
X
X
ꢂ The unit price output should be skipped the first 2
00
01
02
03
04
05
digits.
ꢂ Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6
ꢂ Actual Output : A81025[TAB]SN123456[TAB]76[TAB]
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Procedure
[Data Verifier]
[Data Replacer]
ꢂ Scan “Program” to enter the programming mode.
ꢂ Scan “Replacer Control” and set bar code symbology
to “48”.
ꢂ Scan “Verifier Control” and set bar code symbology to “48”
(Interleaved 2 of 5).
ꢂ
Scan “1st Replacement” and set the identified position
to “00”, then replaced character to “41” (Hex Code of
ꢂ Scan “Identified Data Length” and set the length to “16”.
A).
ꢂ Scan “1st Identified Character” and set the identified
position to “00”, then set the identified character to “39”
(Hex Code of 9).
[Data Organizer]
ꢂ Scan “Organizer Control” and set bar code symbology
to “48”.
[Data Formatter]
ꢂ Scan “Formatter Control” and set bar code symbology to ꢂ Scan “1st Organization” and set the identified position
“48”. to “16”, then set the data transmission to “0” (forward).
ꢂ Scan 1st Insertion” and set the identified position to “06”, ꢂ Scan “2nd Organization” and set the identified position
then inserted characters to “09” (Hex Code of TAB), “53”
(Hex Code of S), “4E” (Hex Code of N).
to “17”, then set the data transmission to “1”
(backward).
ꢂ Scan “2nd Insertion” and set the identified position to “12”,
then inserted character to “09”. In the final, you must scan
“FIN” (Finish) code to terminate this selection.
ꢂ
Scan “END” (Exit) to terminate the programming.
[Important Notice]
ꢂ
Scan “3rd Insertion” and set the identified position to “16”,
then inserted character to “09”. In the final, you must scan
“FIN” (Finish) code to terminate this selection.
Please note that Condensed DataWizard will follow the
preset working flow as below:
Verifier
ꢀ
Formatter
ꢀ
Replacer
ꢀ
Organizer
So when you set the identified position in Data Organizer,
you must consider the inserted data which you already set
via Data Formatter.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbology ID Table
Each AIM Code Identifier contains the three-character string ]cm where:
] = Flag Character
c = Code Character
m = Modifier Character
Cino ID
AIM ID
Cino ID
AIM ID
Code Family
Primary Format
Code Family
Primary Format
Code
Code
Modified
Code
Code
Modified
Character
Character
Character
Character
Character
Character
UPC-A
m
1
EAN/JAN-8
4
1
A
E
N
F
E
UPC-A with 2 supple.
UPC-A with 5 supple.
UPC-E
EAN/JAN-8 with 2 supple.
EAN/JAN-8 with 5 supple.
EAN/JAN-13
2
2
E
m
1
m
1
UPC
EAN/JAN
E
UPC-E with 2 supple.
UPC-E with 5 supple.
EAN/JAN-13 with 2 supple.
EAN/JAN-13 with 5 supple.
2
2
Example: A UPC-A bar code 012345678950 with 2 supplement 12 is
transmitted as ]E0012345678950]E112
Example: A EAN/JAN-8 bar code 49123562 with 5 supplement 12345 is
transmitted as ]E449123562]E212345
Code 128
B
C
D
I
m
1
Code 93
Code 93
H
P
R
S
T
G
H
M
P
m
m
m
0
Code 128
Codabar
C
UCC/EAN-128
Codabar/NW-7
Standard/Industrial 2 of 5
Matrix 2 of 5
Code 11
Code 11
F
S
X
I
m
0
MSI/Plessey
UK/Plessey
Telepen
MSI/Plessey
UK/Plessey
Telepen
K
J
0
B
m
Interleaved 2 of 5
m
GS1 DataBar GS1 Databar
Code 25
X
e
0
Composite
Composite Code
Code 39
China Postal Code
L
X
0
G
W
G
V
A
X
A
L
m
0
0
0
0
0
Code 39
German Postal Code
IATA
M
O
Z
I
3
Code 39 Trioptic
Code 32
IATA
R
m
UCC Coupon Code
PDF417
PDF417/Micro PDF417
Codablock F
Example : A UPC-A 512345678900 + UCC/EAN-128 81010123451297
bar code is transmitted as]E0512345678900]C181010123451297
Example: A EAN-13 9923456789019 + UCC/EAN-128 81010123451297
bar code is transmitted as ]E09923456789019]C181010123451297
Codablock
Korea Post
Y
O
X
UCC Coupon
Korea Post Code
a
Remark: Above examples are given for the transmission of AIM ID.
56
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyboard Function Code Table
No.
00
01
02
03
04
05
06
07
08
09
10
11
ANSI
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
ASCII
00H
01H
02H
03H
04H
05H
06H
07H
08H
09H
0AH
0BH
0CH
0DH
0EH
0FH
Key Function
No.
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
ANSI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
ASCII
10H
11H
Key Function
RESERVED
CTRL (Left)
ALT (Left)
SHIFT
F7
F8
12H
13H
14H
15H
16H
17H
18H
19H
1AH
1BH
1CH
1DH
1EH
1FH
F9
F10
F11
F12
CAPS LOCK
NUM LOCK
ESC
INS (Insert) (Edit)
DEL (Delete) (Edit)
HOME (Edit)
F1
BACK SPACE
HT
TAB
END (Edit)
LF
F2
SUB
ESC
FS
PAGE UP (Edit)
PAGE DOWN (Edit)
UP (Edit)
VT
F3
12
13
14
15
FF
F4
CR
ENTER (CR)
GS
DOWN (Edit)
LEFT (Edit)
SO
F5
F6
RS
SI
US
RIGHT (Edit)
To emulate the keyboard function key input for user definable parameters, user must configure actual content using the
Reserved ASCII 0 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl output will be done
by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP,
COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines.
57
Download from Www.Somanuals.com. All Manuals Search And Download.
ASCII Input Shortcut
To configure the user definable parameters of FuzzyScan via
programming menu, FuzzyScan will ask you to scan your
desired ASCII value in HEX form. You have to refer to the
“HEX/ASCII Table” for details.
HEX/ASCII Reference Table
H
0
1
2
3
4
5
6
7
L
0
1
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
DLE SPACE
0
1
2
3
4
5
6
7
8
9
:
@
A
B
C
D
E
F
P
Q
R
S
T
U
V
W
X
Y
Z
[
`
a
b
c
d
e
f
p
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
!
"
q
Example:
2
r
If you want the scanned data output leading with a Dollar
Sign, you have to set the “Preamble” to “$”. The configuration
procedure is listed below for reference.
3
#
$
%
&
'
s
4
t
5
u
ꢂ Scan the system command – PROGRAM listed on page
6
v
3-24 to enter programming mode.
7
G
H
I
g
h
i
w
ꢂ Scan family code – PREAMBLE to select this family.
8
(
x
9
HT
)
y
ꢂ Refer to the Hex/ASCII Table, you will find the HEX value
of “$” is 24.
A
B
C
D
E
F
LF
SUB
ESC
FS
*
J
j
z
VT
+
,
;
K
L
k
l
{
ꢂ Scan the option code – 2 listed on the fold out back cover.
ꢂ Scan the option code – 4 listed on the fold out back cover.
FF
<
=
>
?
\
|
}
CR
GS
-
M
N
O
]
m
n
o
ꢂ Scan the system command – FIN (Finish) to terminate
SO
RS
.
^
~
Preamble setting.
SI
US
/
_
DEL
ꢂ Scan the system command – End to exit the programming
Example : ASCII “A” → HEX “41”; ASCII “a” → “61”
: High Byte of HEX Value
mode for normal operation.
: Low Byte of HEX Value
58
Download from Www.Somanuals.com. All Manuals Search And Download.
Host Interface Quick Set
RS232 Serial
USB Com Port Emulation
USB HID Standard Mode
USB HID Turbo Mode
Operation Mode Quick Set
ꢁTrigger Mode
Force Mode (Continued power on)
Alternative Mode (Periodic power off)
Presentation Mode (Auto sensing)
Level Mode (Auto power off)
59
Download from Www.Somanuals.com. All Manuals Search And Download.
Option Codes
0
1
2
3
8
9
4
5
6
7
C
D
E
F
A
B
FIN (Finish)
END (Exit)
60
Download from Www.Somanuals.com. All Manuals Search And Download.
System Commands
PROGRAM
(Enter Programming Mode)
System Information List
(SYSLIST)
Save User Default
FIN (Finish)
PowerTool Host Link
User Default
END
(Exit Programming Mode)
Factory Default
Master Default
ꢂ
ꢂ
Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value.
Master Default: After scanning “Master Default” command, the scanner will remain the pre-set parameters of Host Interface Selection, Keyboard Interface
Control (except Record Suffix; Preamble; Postamble), Serial Interface Control (except Record Suffix; Preamble; Postamble), and Wand/Laser Emulation
Control, the rest of parameters will be returned to default value.
ꢂ
User Default: After scanning” Save User Default” command, all current parameters will be stored to the flash memory. Once you change the parameter and
would like to return to previous setting, please scan “User Default”.
61
Download from Www.Somanuals.com. All Manuals Search And Download.
Indications
Power Indicator
Status Indicator
OK/NG Indicator
Normal Operation
Indicators
Status
Descriptions
Beeper
Power on beep
Power
Steady blue
OK/NG
Power on
Off
Off
Off
Off
Good read (OK reading)
No read (NG reading)
Off
Off
1 green blink
1 red blink
1 good read beep
1 no read beep
Test Mode Reading Rate Information
Indicators
Status
Reading Rate
Power
Beeper
OK/NG
Steady Green
Steady Green
Steady Red
100%
Steady Green
Steady Red
80 to 99%
50 to 79%
20 to 49%
0 to 19%
1 blue blink per 1 sec.
One short beep
Steady Green
Steady Orange
Steady Red
Steady Orange
Steady Red
62