IN STAL LA TIO N I NST RUCT IONS
Medium Flat Panel
Pivot/Pitch Wall Mount
Model JWP-V
The JWP Pivot/Pitch wall mount is designed for
mounting a medium sized flat panel display. The mount
can be tilted up and down to 15° of center as well as
pivot left and right.
The JWP is shipped with the VESA® 100mm/100mm
Centris™ interface which is compatible with most
medium flat panels.
To accommodate other mounting patterns in displays,
the JWP comes with a VESA Plate that accommodates
other VESA mounting patterns.
By design, the JWP can be configured to fit your medium
flat panel display, providing that your display does not
exceed the specified weight rating.
JWP-V
BEFORE YOU BEGIN
x
CAUTION: To prevent damage to your display and/or the JWP, which could affect or void factory
warranty, thoroughly study all instructions and illustrations before you begin to install the mount. Pay
particular attention to ALL Warnings and Cautions in this document.
x
x
The maximum weight allowable for use with the JWP wall mount is 75 lbs (34 kg).
The JWP wall mount is designed to be installed using wall studs or supporting framework. The structure to which
the JWP wall mount is anchored must be capable of supporting five times the total weight of the mount and all
attached equipment.
x
If you have any questions about this installation, contact Chief Manufacturing at 1-800-582-6480.
CHIEF MANUFACTURING INC.
8832-000134 Rev B
©2006 Chief Manufacturing
12/06
1-800-582-6480 952-894-6280 FAX 952-894-6918
8401 EAGLE CREEK PARKWAY, STE. 700
SAVAGE, MINNESOTA 55378 USA
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
CONTENTS
TOOLS REQUIRED FOR
INSTALLATION
DIMENSIONAL DRAWING ..................................... 2
TOOLS REQUIRED FOR INSTALLATION............ 3
INSPECT UNIT BEFORE INSTALLING................. 3
SPECIFICATIONS ................................................... 3
INTRODUCTION...................................................... 4
PARTS....................................................................... 5
PARTS (Continued).................................................. 6
SECURE WALL BRACKET..................................... 7
INSTALLATION........................................................ 7
x
x
x
x
Electric drill and bit set
Hex wrench set
Phillips screwdriver
Level
NOTE: Other tools may be required depending on your
display, JWP configuration and method of
installation.
100mm x 100mm Flush and Recessed Mount
Installation.............................................................. 7
INSPECT UNIT BEFORE
INSTALLING
Flush Mount Installation ....................................... 7
Recess Mount Installation.................................... 8
Interface Bracket Installation................................ 9
200mm x 100mm Pattern..................................... 10
300mm x 100mm Pattern..................................... 10
300mm x 200mm Pattern..................................... 11
400mm x 200mm Pattern..................................... 11
200mm x 200mm Pattern..................................... 12
Attach Display to Mount (Centris Bracket).......... 13
ATTACH MOUNT TO WALL BRACKET............. 13
CABLE MANAGEMENT .......................................... 14
ADJUSTMENTS....................................................... 14
Lateral Tension Adjustment ................................. 14
Pitch Tension Adjustment .................................... 14
WARNING: Watch for pinch points. Do not put
your fingers between movable parts.
1. Carefully inspect mount for shipping damage. If any
damage is apparent, call your carrier claims agent
and do not continue with installation until carrier has
reviewed damage.
NOTE: Read all instructions before starting
installation.
2. Lay out components to ensure you have all required
parts before proceeding (see PARTS on page 6). If
you are missing any listed parts, contact Customer
Service at: 1-800/582-6480.
SPECIFICATIONS
Table 1. JWP Specifications
Depth from
Wall
3.35” (85.07mm)
Maximum
Extension
Not Applicable
6.0” x 8.32” x 3.35”
Dimensions
W x H x D
(152 x 211.43 x 85.07mm)
Weight
75 lbs (34kg)
Capacity
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
200mm x 200mm
INTRODUCTION
200mm x 100mm
There are 3 main steps in the JWP-V installation
process. These steps are:
x
x
x
Selecting an appropriate mounting configuration.
Connect display cables
Making required adjustments
Before starting the installation process, determine the
correct mounting hole configuration for your display by
reviewing the information located within Table 2 at right.
NOTE: If the displays mounting hole configuration does
not match those identified at right, a custom MSB
interface is required. Refer to a Chief Mfg. cross
the appropriate MSB for your display.
100mm x 100mm
Figure 1. Typical VESA Mounting Hole
configurations
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
PARTS
Centris Bracket
(See notes)
10
Set Screw (see notes)
BAG A
BAG B
BAG C
BAG D
BAG E
Figure 2. JWP-V Components
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
PARTS (Continued)
Table 2 shows the individual part and parts bags shipped with JWP parts.
Table 2. JWP Parts List
Item
10
Bag
—
Description
Qty Notes
MSP-MA MOUNT (with Centris bracket)
Interface Bracket
1
1
20
—
30
—
Wall Bracket
1
2
Use with 40
40
—
Lag Screws, 3/8” x 3”
Use with 30
No spacers needed for
100mm x 100mm flush
mounted Centris
bracket.
50
Phillips Head Cap Screw, M4 X 12mm
4
For 200mm x 100mm
and 300mm x 100mm
60
70
Phillips Flat Head Machine Screw, M4 X 16mm
Phillips Head Cap Screw, M4 X 20mm
6
4
A
For 100mm x 100mm
recess mounted Centris
bracket. Use with 120.
Used to mount display
with Interface bracket to
Centris bracket
80
90
Phillips Head Cap Screw, M4 X 8mm
Phillips Head Cap Screw, M6 X 20mm
4
8
For 300mm x 200mm
and 400mm x 200mm
B
C
100
110
Phillips Head Cap Screw, M6 X 30mm
Phillips Head Cap Screw, M6 X 45mm
4
4
Use 4 of the 8 spacers
for 100mm x 100mm
recess mounted Centris
bracket.
120
Nylon Spacer, .75 x .25 x .25
8
130
140
150
180
190
200
Nylon Spacer, .625 x .194 x .125
Hex Key, 5/32”
6
1
1
4
4
4
For Set Screw
For Tension Adjust.
Use with 120
D
E
Hex Key, 3/16”
Phillips Head Cap Screw, M5 X 20mm
Phillips Head Cap Screw, M5 X 30mm
Phillips Head Cap Screw, M5 X 45mm
Use with 130
Use with 130
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
SECURE WALL BRACKET
WARNING: It is the responsibility of the
installer to verify that the surface to which the mount
is anchored will safely support the combined load of
all attached components and equipment.
Install wall bracket as follows:
1. Determine exact mounting location prior to
installation, considering unit’s swing arm and
extension radius.
Pilot Holes
2. Using wall bracket (30) as a template, mark two pilot
holes. (See Figure 1)
30
3. Drill two ¼” pilot holes a minimum depth of 2” into
wood stud.
40
NOTE: Make sure wall bracket is level before installing
lag bolts.
4. Using a 9/16” socket wrench, install two lag bolts (40)
to wall. Do not over-tighten the lag bolts.
IMPORTANT: Over-tightening lag bolts may cause
bracket to compress into soft wall surface, resulting in
difficult mount installation or improper engaging of set
screw (Ref. “Attach Mount to Wall Bracket,” page 13,
step 2). If this occurs, remove bracket, install 3/8”
steel washers as required between bracket and wall
surface, and reinstall bracket.
Figure 1. Secure Wall Bracket
60
INSTALLATION
100mm x 100mm Flush and Recessed Mount
Installation
Flush Mount Installation
To flush mount Centris Bracket:
1. Start two M4 x 12mm screws (60) into top mounting
holes (not shown) on display.
2. Align mounting holes on Centris Bracket with screws
installed on display. Hang display on Centris Bracket
(see Figure 2).
Centris Bracket
Figure 2. Flush Mount Centris Bracket to Display
3. Install two remaining M4 x 12mm screws (60) into
bottom mounting holes on display.
4. Tighten four M4 x 12mm screws (60) screws.
5. Proceed to “Attach Mount to Wall Bracket” section of
this manual.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
Recess Mount Installation
60
To recess mount Centris Bracket:
1. Lay display down on a flat surface.
CAUTION: Make sure surface is clean and
free of dirt and debris before laying display down.
100
2. Select four screws M4 x 20mm screws (60) and four
spacers (100) from parts bag.
Display
3. Place four spacers (100) over mounting holes on
back of display (see Figure 3).
4. Align mounting holes on Centris bracket with spacers
installed on display.
5. Install four M4 x 20mm screws (60) to attach Centris
bracket to display (see Figure 3).
6. Tighten four M4 x 20mm screws (60) screws.
7. Proceed to “Attach Mount to Wall Bracket” section of
this manual.
Figure 3. Recess Mount Centris Bracket to Display
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
Interface Bracket Installation
SCREW*
(BAG A OR B)
DISPLAY
The following sections describe how to install the
interface bracket (20) for a specific hole-pattern on
your display.
MOUNTING
HOLE
This procedure provides a general guideline to follow
when installing the interface bracket after selecting the
mounting-hole pattern procedure that matches your
display. For example: To install the interface bracket
using the 200mm x 100mm mounting-hole pattern, use
the procedure on page 10.
SPACER
(BAG C)
20
WARNING: You must use proper attaching
hardware to install the interface bracket. Failure to
use proper attaching hardware may result in
equipment damage or serious personal injury.
Figure 4. Attaching Interface Bracket to Display
1. Lay the interface bracket (20) over the mounting
holes on the back of the display, making sure to
center the interface bracket as much as possible.
NOTE: A typical example of where to place the spacers
between the display and interface bracket is
shown in Figure 4.
2. In general, to install the interface bracket, do the
following:
a. Select the appropriate mounting-hole pattern, as
described in the following sections, to attach
the interface bracket (20) to back of display.
b. Select the appropriate screws from Bag A or B
and spacers from Bag C to mount the interface
bracket to the back of the display.
c. Tighten each screw. To prevent equipment
damage, do not over-tighten the screws.
CAUTION: The screw and spacer length must
not exceed the depth of the mounting-hole. Using
improper hardware may result in equipment damage
or serious personal injury.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
200mm x 100mm Pattern
For the 200mm x 100mm hole pattern, do the
following:
1. Select six flat head M4 screws (60) from Bag A and
six spacers (130) from Bag C.
2. Attach the interface bracket (20) using the hole-
pattern on the back of your display as shown in
Figure 5.
3. Tighten each screw. To prevent equipment damage,
do not over-tighten the screws.
Figure 5. Display with 200mm x 100mm Hole Pattern
300mm x 100mm Pattern
For the 300mm x 100mm hole pattern, do the
following:
1. Select four flat head M4 screws (60) from Bag A and
four spacers (130) from Bag C.
2. Attach the interface bracket (20) using the hole-
pattern on the back of your display as shown in
Figure 6.
3. Tighten each screw. To prevent equipment damage,
do not over-tighten the screws.
Figure 6. Display with 300mm x 100mm Hole Pattern
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
300mm x 200mm Pattern
For the 300mm x 200mm hole pattern, do the
following:
1. Select eight Phillips head M6 screws (110) from
Bag B and eight spacers (120) from Bag C.
2. Attach the interface bracket (20) using the hole-
pattern on the back of your display as shown in
Figure 7.
3. Tighten each screw. To prevent equipment damage,
do not over-tighten the screws.
Figure 7. Display with 300mm x 200mm Hole Pattern
400mm x 200mm Pattern
For the 400mm x 200mm hole pattern, do the
following:
1. Select six Phillips head M6 screws (90) from Bag B
and six spacers (120) from Bag C.
2. Attach the interface bracket (20) using the hole-
pattern on the back of your display as shown in
Figure 8.
3. Tighten each screw. To prevent equipment damage,
do not over-tighten the screws.
Figure 8. Display with 400mm x 200mm Hole Pattern
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
200mm x 200mm Pattern
For the 200mm x 200mm hole pattern, do the
following:
1. Select the applicable screws as follows:
a. If using square hole on interface bracket (20),
select four Phillips head M4 screws from Bag A.
OR
b. If using round hole on interface bracket (20),
select four Phillips head M6 screws from Bag B.
c. Select spacers (120) or (130) from Bag C.
2. Attach the interface bracket (20) using the hole-
pattern on the back of your display as shown in
Figure 9 and Figure 10 .
3. Tighten each screw. To prevent equipment damage,
do not over-tighten the screws.
Figure 9. Display with 200mm x 200mm Hole Pattern
For round hole,
use M6 screws
For square hole,
use M4 screws
Figure 10. Select Round Hole or Square Hole
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
Attach Display to Mount (Centris Bracket)
Display
After attaching the interface bracket onto the
display, the next step is to attach the display to the
mount (Centris bracket).
Centris
Bracket
To attach the display to the Centris bracket, do the
following:
1. Select four Phillips head M4 x 8mm screws (80) from
Bag A.
2. Start two M4 x 8mm screws (80, Bag A) into top
mounting holes on display (see Figure 11)
80
3. Align mounting holes on Centris bracket with screws
installed on display. Hang display on Centris bracket.
20
4. Install two remaining M4 x 8mm screws (80) from
Bag A into the bottom mounting holes on the display.
Figure 11. Attach Display to Mount
5. Tighten four screws.
6. Proceed to the “Cable Management” procedure.
ATTACH MOUNT TO WALL BRACKET
10
To attach mount to wall bracket:
1. Align top of mount (10) with top of wall bracket (30).
Push bottom of mount against bottom of wall bracket
until mount fits snugly in place. (seeFigure 12)
2. Using 5/32” hex wrench (140), secure mount to wall
bracket by tightening set screw (see Figure 13).
Ensure set screw engages back side of bracket to
properly secure mount.
30
Figure 12. Attach Mount to Wall Bracket
10
Set Screw
Figure 13. Tighten Set Screw
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
JWP-V
CABLE MANAGEMENT
Lateral Tension Adjustment Bolt
WARNING: Make sure your cables do not run
through a pinch points. Do not put your fingers
between movable parts.
For cable management (not shown), connect and
secure power/audio/video cables, making sure to
leave sufficient slack to allow for movement of the
display.
ADJUSTMENTS
Lateral Tension Adjustment
To adjust Lateral Tension:
1. Move arms laterally to check for desired tension.
2. Using a 3/16” hex wrench slightly tighten or loosen
lateral tension adjustment bolts (seeFigure 14).
Figure 14. Adjust Lateral Tension
3. Repeat Steps 1 and 2 until desired tension is
obtained.
Pitch Tension Adjustment
To adjust Pitch Tension:
1. Tilt display to check for desired tension.
2. If pitch tension in Centris Bracket requires
adjustment, perform the following steps:
d. Remove Display from Centris Bracket.
e. Using a 3/16” hex wrench, slightly tighten or
loosen pitch adjustment bolt to adjust Centris
Bracket as needed (see Figure 15).
Pitch Adjustment Bolt
f. Reinstall display.
Figure 15. Adjust Pitch Tension
3. Repeat Steps 1 and 2 until desired tension is
obtained.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
|