Chief Manufacturing TV Mount JWP V User Manual

IN STAL LA TIO N I NST RUCT IONS  
Medium Flat Panel  
Pivot/Pitch Wall Mount  
Model JWP-V  
The JWP Pivot/Pitch wall mount is designed for  
mounting a medium sized flat panel display. The mount  
can be tilted up and down to 15° of center as well as  
pivot left and right.  
The JWP is shipped with the VESA® 100mm/100mm  
Centris™ interface which is compatible with most  
medium flat panels.  
To accommodate other mounting patterns in displays,  
the JWP comes with a VESA Plate that accommodates  
other VESA mounting patterns.  
By design, the JWP can be configured to fit your medium  
flat panel display, providing that your display does not  
exceed the specified weight rating.  
JWP-V  
BEFORE YOU BEGIN  
x
CAUTION: To prevent damage to your display and/or the JWP, which could affect or void factory  
warranty, thoroughly study all instructions and illustrations before you begin to install the mount. Pay  
particular attention to ALL Warnings and Cautions in this document.  
x
x
The maximum weight allowable for use with the JWP wall mount is 75 lbs (34 kg).  
The JWP wall mount is designed to be installed using wall studs or supporting framework. The structure to which  
the JWP wall mount is anchored must be capable of supporting five times the total weight of the mount and all  
attached equipment.  
x
If you have any questions about this installation, contact Chief Manufacturing at 1-800-582-6480.  
CHIEF MANUFACTURING INC.  
8832-000134 Rev B  
©2006 Chief Manufacturing  
12/06  
1-800-582-6480 952-894-6280 FAX 952-894-6918  
8401 EAGLE CREEK PARKWAY, STE. 700  
SAVAGE, MINNESOTA 55378 USA  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
CONTENTS  
TOOLS REQUIRED FOR  
INSTALLATION  
DIMENSIONAL DRAWING ..................................... 2  
TOOLS REQUIRED FOR INSTALLATION............ 3  
INSPECT UNIT BEFORE INSTALLING................. 3  
SPECIFICATIONS ................................................... 3  
INTRODUCTION...................................................... 4  
PARTS....................................................................... 5  
PARTS (Continued).................................................. 6  
SECURE WALL BRACKET..................................... 7  
INSTALLATION........................................................ 7  
x
x
x
x
Electric drill and bit set  
Hex wrench set  
Phillips screwdriver  
Level  
NOTE: Other tools may be required depending on your  
display, JWP configuration and method of  
installation.  
100mm x 100mm Flush and Recessed Mount  
Installation.............................................................. 7  
INSPECT UNIT BEFORE  
INSTALLING  
Flush Mount Installation ....................................... 7  
Recess Mount Installation.................................... 8  
Interface Bracket Installation................................ 9  
200mm x 100mm Pattern..................................... 10  
300mm x 100mm Pattern..................................... 10  
300mm x 200mm Pattern..................................... 11  
400mm x 200mm Pattern..................................... 11  
200mm x 200mm Pattern..................................... 12  
Attach Display to Mount (Centris Bracket).......... 13  
ATTACH MOUNT TO WALL BRACKET............. 13  
CABLE MANAGEMENT .......................................... 14  
ADJUSTMENTS....................................................... 14  
Lateral Tension Adjustment ................................. 14  
Pitch Tension Adjustment .................................... 14  
WARNING: Watch for pinch points. Do not put  
your fingers between movable parts.  
1. Carefully inspect mount for shipping damage. If any  
damage is apparent, call your carrier claims agent  
and do not continue with installation until carrier has  
reviewed damage.  
NOTE: Read all instructions before starting  
installation.  
2. Lay out components to ensure you have all required  
parts before proceeding (see PARTS on page 6). If  
you are missing any listed parts, contact Customer  
Service at: 1-800/582-6480.  
SPECIFICATIONS  
Table 1. JWP Specifications  
Depth from  
Wall  
3.35” (85.07mm)  
Maximum  
Extension  
Not Applicable  
6.0” x 8.32” x 3.35”  
Dimensions  
W x H x D  
(152 x 211.43 x 85.07mm)  
Weight  
75 lbs (34kg)  
Capacity  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
200mm x 200mm  
INTRODUCTION  
200mm x 100mm  
There are 3 main steps in the JWP-V installation  
process. These steps are:  
x
x
x
Selecting an appropriate mounting configuration.  
Connect display cables  
Making required adjustments  
Before starting the installation process, determine the  
correct mounting hole configuration for your display by  
reviewing the information located within Table 2 at right.  
NOTE: If the displays mounting hole configuration does  
not match those identified at right, a custom MSB  
interface is required. Refer to a Chief Mfg. cross  
reference or visit to www.chiefmfg.com to identify  
the appropriate MSB for your display.  
100mm x 100mm  
Figure 1. Typical VESA Mounting Hole  
configurations  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
PARTS  
Centris Bracket  
(See notes)  
10  
Set Screw (see notes)  
BAG A  
BAG B  
BAG C  
BAG D  
BAG E  
Figure 2. JWP-V Components  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
PARTS (Continued)  
Table 2 shows the individual part and parts bags shipped with JWP parts.  
Table 2. JWP Parts List  
Item  
10  
Bag  
Description  
Qty Notes  
MSP-MA MOUNT (with Centris bracket)  
Interface Bracket  
1
1
20  
30  
Wall Bracket  
1
2
Use with 40  
40  
Lag Screws, 3/8” x 3”  
Use with 30  
No spacers needed for  
100mm x 100mm flush  
mounted Centris  
bracket.  
50  
Phillips Head Cap Screw, M4 X 12mm  
4
For 200mm x 100mm  
and 300mm x 100mm  
60  
70  
Phillips Flat Head Machine Screw, M4 X 16mm  
Phillips Head Cap Screw, M4 X 20mm  
6
4
A
For 100mm x 100mm  
recess mounted Centris  
bracket. Use with 120.  
Used to mount display  
with Interface bracket to  
Centris bracket  
80  
90  
Phillips Head Cap Screw, M4 X 8mm  
Phillips Head Cap Screw, M6 X 20mm  
4
8
For 300mm x 200mm  
and 400mm x 200mm  
B
C
100  
110  
Phillips Head Cap Screw, M6 X 30mm  
Phillips Head Cap Screw, M6 X 45mm  
4
4
Use 4 of the 8 spacers  
for 100mm x 100mm  
recess mounted Centris  
bracket.  
120  
Nylon Spacer, .75 x .25 x .25  
8
130  
140  
150  
180  
190  
200  
Nylon Spacer, .625 x .194 x .125  
Hex Key, 5/32”  
6
1
1
4
4
4
For Set Screw  
For Tension Adjust.  
Use with 120  
D
E
Hex Key, 3/16”  
Phillips Head Cap Screw, M5 X 20mm  
Phillips Head Cap Screw, M5 X 30mm  
Phillips Head Cap Screw, M5 X 45mm  
Use with 130  
Use with 130  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
SECURE WALL BRACKET  
WARNING: It is the responsibility of the  
installer to verify that the surface to which the mount  
is anchored will safely support the combined load of  
all attached components and equipment.  
Install wall bracket as follows:  
1. Determine exact mounting location prior to  
installation, considering unit’s swing arm and  
extension radius.  
Pilot Holes  
2. Using wall bracket (30) as a template, mark two pilot  
holes. (See Figure 1)  
30  
3. Drill two ¼” pilot holes a minimum depth of 2” into  
wood stud.  
40  
NOTE: Make sure wall bracket is level before installing  
lag bolts.  
4. Using a 9/16” socket wrench, install two lag bolts (40)  
to wall. Do not over-tighten the lag bolts.  
IMPORTANT: Over-tightening lag bolts may cause  
bracket to compress into soft wall surface, resulting in  
difficult mount installation or improper engaging of set  
screw (Ref. “Attach Mount to Wall Bracket,” page 13,  
step 2). If this occurs, remove bracket, install 3/8”  
steel washers as required between bracket and wall  
surface, and reinstall bracket.  
Figure 1. Secure Wall Bracket  
60  
INSTALLATION  
100mm x 100mm Flush and Recessed Mount  
Installation  
Flush Mount Installation  
To flush mount Centris Bracket:  
1. Start two M4 x 12mm screws (60) into top mounting  
holes (not shown) on display.  
2. Align mounting holes on Centris Bracket with screws  
installed on display. Hang display on Centris Bracket  
(see Figure 2).  
Centris Bracket  
Figure 2. Flush Mount Centris Bracket to Display  
3. Install two remaining M4 x 12mm screws (60) into  
bottom mounting holes on display.  
4. Tighten four M4 x 12mm screws (60) screws.  
5. Proceed to “Attach Mount to Wall Bracket” section of  
this manual.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
Recess Mount Installation  
60  
To recess mount Centris Bracket:  
1. Lay display down on a flat surface.  
CAUTION: Make sure surface is clean and  
free of dirt and debris before laying display down.  
100  
2. Select four screws M4 x 20mm screws (60) and four  
spacers (100) from parts bag.  
Display  
3. Place four spacers (100) over mounting holes on  
back of display (see Figure 3).  
4. Align mounting holes on Centris bracket with spacers  
installed on display.  
5. Install four M4 x 20mm screws (60) to attach Centris  
bracket to display (see Figure 3).  
6. Tighten four M4 x 20mm screws (60) screws.  
7. Proceed to “Attach Mount to Wall Bracket” section of  
this manual.  
Figure 3. Recess Mount Centris Bracket to Display  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
Interface Bracket Installation  
SCREW*  
(BAG A OR B)  
DISPLAY  
The following sections describe how to install the  
interface bracket (20) for a specific hole-pattern on  
your display.  
MOUNTING  
HOLE  
This procedure provides a general guideline to follow  
when installing the interface bracket after selecting the  
mounting-hole pattern procedure that matches your  
display. For example: To install the interface bracket  
using the 200mm x 100mm mounting-hole pattern, use  
the procedure on page 10.  
SPACER  
(BAG C)  
20  
WARNING: You must use proper attaching  
hardware to install the interface bracket. Failure to  
use proper attaching hardware may result in  
equipment damage or serious personal injury.  
Figure 4. Attaching Interface Bracket to Display  
1. Lay the interface bracket (20) over the mounting  
holes on the back of the display, making sure to  
center the interface bracket as much as possible.  
NOTE: A typical example of where to place the spacers  
between the display and interface bracket is  
shown in Figure 4.  
2. In general, to install the interface bracket, do the  
following:  
a. Select the appropriate mounting-hole pattern, as  
described in the following sections, to attach  
the interface bracket (20) to back of display.  
b. Select the appropriate screws from Bag A or B  
and spacers from Bag C to mount the interface  
bracket to the back of the display.  
c. Tighten each screw. To prevent equipment  
damage, do not over-tighten the screws.  
CAUTION: The screw and spacer length must  
not exceed the depth of the mounting-hole. Using  
improper hardware may result in equipment damage  
or serious personal injury.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
200mm x 100mm Pattern  
For the 200mm x 100mm hole pattern, do the  
following:  
1. Select six flat head M4 screws (60) from Bag A and  
six spacers (130) from Bag C.  
2. Attach the interface bracket (20) using the hole-  
pattern on the back of your display as shown in  
Figure 5.  
3. Tighten each screw. To prevent equipment damage,  
do not over-tighten the screws.  
Figure 5. Display with 200mm x 100mm Hole Pattern  
300mm x 100mm Pattern  
For the 300mm x 100mm hole pattern, do the  
following:  
1. Select four flat head M4 screws (60) from Bag A and  
four spacers (130) from Bag C.  
2. Attach the interface bracket (20) using the hole-  
pattern on the back of your display as shown in  
Figure 6.  
3. Tighten each screw. To prevent equipment damage,  
do not over-tighten the screws.  
Figure 6. Display with 300mm x 100mm Hole Pattern  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
300mm x 200mm Pattern  
For the 300mm x 200mm hole pattern, do the  
following:  
1. Select eight Phillips head M6 screws (110) from  
Bag B and eight spacers (120) from Bag C.  
2. Attach the interface bracket (20) using the hole-  
pattern on the back of your display as shown in  
Figure 7.  
3. Tighten each screw. To prevent equipment damage,  
do not over-tighten the screws.  
Figure 7. Display with 300mm x 200mm Hole Pattern  
400mm x 200mm Pattern  
For the 400mm x 200mm hole pattern, do the  
following:  
1. Select six Phillips head M6 screws (90) from Bag B  
and six spacers (120) from Bag C.  
2. Attach the interface bracket (20) using the hole-  
pattern on the back of your display as shown in  
Figure 8.  
3. Tighten each screw. To prevent equipment damage,  
do not over-tighten the screws.  
Figure 8. Display with 400mm x 200mm Hole Pattern  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
200mm x 200mm Pattern  
For the 200mm x 200mm hole pattern, do the  
following:  
1. Select the applicable screws as follows:  
a. If using square hole on interface bracket (20),  
select four Phillips head M4 screws from Bag A.  
OR  
b. If using round hole on interface bracket (20),  
select four Phillips head M6 screws from Bag B.  
c. Select spacers (120) or (130) from Bag C.  
2. Attach the interface bracket (20) using the hole-  
pattern on the back of your display as shown in  
Figure 9 and Figure 10 .  
3. Tighten each screw. To prevent equipment damage,  
do not over-tighten the screws.  
Figure 9. Display with 200mm x 200mm Hole Pattern  
For round hole,  
use M6 screws  
For square hole,  
use M4 screws  
Figure 10. Select Round Hole or Square Hole  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
Attach Display to Mount (Centris Bracket)  
Display  
After attaching the interface bracket onto the  
display, the next step is to attach the display to the  
mount (Centris bracket).  
Centris  
Bracket  
To attach the display to the Centris bracket, do the  
following:  
1. Select four Phillips head M4 x 8mm screws (80) from  
Bag A.  
2. Start two M4 x 8mm screws (80, Bag A) into top  
mounting holes on display (see Figure 11)  
80  
3. Align mounting holes on Centris bracket with screws  
installed on display. Hang display on Centris bracket.  
20  
4. Install two remaining M4 x 8mm screws (80) from  
Bag A into the bottom mounting holes on the display.  
Figure 11. Attach Display to Mount  
5. Tighten four screws.  
6. Proceed to the “Cable Management” procedure.  
ATTACH MOUNT TO WALL BRACKET  
10  
To attach mount to wall bracket:  
1. Align top of mount (10) with top of wall bracket (30).  
Push bottom of mount against bottom of wall bracket  
until mount fits snugly in place. (seeFigure 12)  
2. Using 5/32” hex wrench (140), secure mount to wall  
bracket by tightening set screw (see Figure 13).  
Ensure set screw engages back side of bracket to  
properly secure mount.  
30  
Figure 12. Attach Mount to Wall Bracket  
10  
Set Screw  
Figure 13. Tighten Set Screw  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
JWP-V  
CABLE MANAGEMENT  
Lateral Tension Adjustment Bolt  
WARNING: Make sure your cables do not run  
through a pinch points. Do not put your fingers  
between movable parts.  
For cable management (not shown), connect and  
secure power/audio/video cables, making sure to  
leave sufficient slack to allow for movement of the  
display.  
ADJUSTMENTS  
Lateral Tension Adjustment  
To adjust Lateral Tension:  
1. Move arms laterally to check for desired tension.  
2. Using a 3/16” hex wrench slightly tighten or loosen  
lateral tension adjustment bolts (seeFigure 14).  
Figure 14. Adjust Lateral Tension  
3. Repeat Steps 1 and 2 until desired tension is  
obtained.  
Pitch Tension Adjustment  
To adjust Pitch Tension:  
1. Tilt display to check for desired tension.  
2. If pitch tension in Centris Bracket requires  
adjustment, perform the following steps:  
d. Remove Display from Centris Bracket.  
e. Using a 3/16” hex wrench, slightly tighten or  
loosen pitch adjustment bolt to adjust Centris  
Bracket as needed (see Figure 15).  
Pitch Adjustment Bolt  
f. Reinstall display.  
Figure 15. Adjust Pitch Tension  
3. Repeat Steps 1 and 2 until desired tension is  
obtained.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Decker Microwave Oven MY23PG User Manual
Bosch Appliances Oven HBA36B60W User Manual
Bosch Appliances Universal Remote 2400ES User Manual
Braun Electric Shaver EP 50 User Manual
Brother Fax Machine fax560 User Manual
Bryant Furnace 313AAV User Manual
Bushnell GPS Receiver 364000 User Manual
Chamberlain Garage Door Opener Series 1200 User Manual
Char Broil Gas Grill 463250811 User Manual
Christie Digital Systems Flat Panel Television FP400 User Manual