Chief Manufacturing Indoor Furnishings FHP 110 User Manual

I N S T A L L A T I O N I N S T R U C T I O N S  
Small Flat Panel Ceiling Mount  
with Adjustable Column (FHP-110)  
The FHP is a sleek, Centris™ mounting system designed for all  
VESA® 75mm/100mm compliant displays. The mount includes  
an adjustable column, cable management, and a variety of  
screen positioning options. The all-metal mount is available in  
either silver, black or white.  
The slender column on the mount is finely finished with easy  
adjustment between 23 inches and 42 inches in 1 inch incre-  
ments. The snap on cable management cover, fitting snugly  
against the column, conceals unsightly cabling.  
The mount rotates 360 degrees, allowing portrait or landscape  
mounting of your display. The friction-adjustable pivot points  
include 15 degrees of up and down tilt for customized move-  
ment.  
BEFORE YOU BEGIN  
Caution: To prevent damage to the FHP, which could affect or void the Factory warranty, and to the equip-  
ment that will be attached to it, thoroughly study all instructions and illustrations before you begin the  
installation. Pay particular attention to the “Important Warnings and Precautions” on Page 1.  
• The maximum weight to be installed on the FHP ceiling mount is 40 pounds (18.1 Kg)  
• The FHP ceiling mount is designed to be installed using supporting framework. The structure to which the FHP  
ceiling mount is anchored must be capable of supporting five times the total weight of the mount and all attached  
equipment.  
• If you have any questions about this installation, contact Chief Manufacturing at 1-800-582-6480.  
PART NO. 8804-000153  
2006 Chief Manufacturing  
CHIEF MANUFACTURING INC.  
1-800-582-6480 952-894-6280 FAX 952-894-6918  
8401 EAGLE CREEK PARKWAY, STE.700  
SAVAGE, MINNESOTA 55378 USA  
Printed in USA 12-06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
FHP  
DRAWINGS  
Ceiling Plate  
Set Screw  
Outer Column  
Socket Head Cap Screw  
Nylon Washer  
Cable Management Cover  
Inner Column  
Lock Nut  
M4 X .7 X 12mm Phillips pan head screws  
M4 X .7 X 20mm or M4 X .7 X 30mm  
Phillips pan head screws  
(optional)  
Phillips Pan Head Screw  
(Adjustment Screw)  
Spacers  
Phillips Pan Head Screw  
(Adjustment Screw)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
FHP  
INSPECT THE UNIT BEFORE INSTALLING  
WARNING: Watch for pinch points. Do not put your fingers  
between movable parts.  
1. Carefully inspect the FHP for shipping damage. If any damage  
is apparent, call your carrier claims agent and do not continue  
with the installation until the carrier has reviewed the damage.  
NOTE: Read all instructions before starting installation.  
2. Lay out components to ensure you have all the required parts  
before proceeding (see FHP drawing on page 2).  
FHP INSTALLATION  
WARNING: It is the responsibility of the installer to verify that  
the surface to which the FHP is anchored will  
safety support the combined load of all attached  
components and equipment.  
Install the FHP as follows:  
Figure 1. Outer Column Installation  
1. Determine the exact mounting location prior to installation,  
considering the unit’s swing radius.  
WARNING: Improper installation can result in serious per-  
sonal injury! Make sure that the structural mem-  
bers can support a redundant weight factor five  
times the total weight of the equipment: if not,  
reinforce the structure before installing the FWP.  
2. Secure the ceiling plate at the desired location.  
3. Thread the outer column with pipe adapter securely into the  
ceiling plate (see Figure 1).  
4. Using the set screw, secure the outer column in the ceiling  
plate.  
5. Install the inner column into outer column at desired height and  
secure using socket head cap screw, Nylon washer, and lock  
nut (see Figure 2).  
Figure 2. Mount on Outer Column  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
FHP  
DISPLAY INSTALLATION  
Install the display as follows:  
VESA Compliant Flush Mounting  
CAUTION: If monitor uses a screw size other than M4, DO NOT  
use the M4 screws provided. Using the wrong screws  
could result in damage to your display.  
1. Start two M4 X .7 X 12mm Phillips pan head screws in the top  
mounting holes of your display.  
2. Matching the hole pattern on your display with the hole pattern  
on the mount, hang the mount from the two screws started in  
Step A (see Figure 3).  
3. Install two remaining Phillips pan head screws through the  
mount and into the mounting holes of your display.  
4. Secure your display to the mount by tightening the four Phil-  
lips pan head screws.  
5. Connect and secure power/audio/video cables, making sure to  
leave sufficient slack to allow for movement of the display.  
VESA Compliant Recessed Mounting  
Figure 3. Install Flush Mount Display on Bracket  
1. Place four 1/2” X 3/8” Nylon spacers or four 1/2” X 3/4”  
Nylon spacers, as necessary, over the mounting holes of your  
display (see Figure 4).  
2. Place the mount over the Nylon spacers, matching the hole pat-  
tern on your display (75mm or 100mm) with the hole pattern  
on the mount.  
3. Using four M4 X .7 X 20mm Phillips pan head screws for 1/2”  
X 3/8” Nylon spacer installation or four M4 X .7 X 30mm  
Phillips pan head screws for the 1/2” X 3/4” Nylon spacer  
installation, secure the mount to your display.  
4. Connect and secure power/audio/video cables, making sure to  
leave sufficient slack to allow for movement of the display.  
Non-VESA Compliant Mounts  
1. Contact Chief Manufacturing for custom interface brackets.  
Figure 4. Install Recessed Mount Display on Bracket  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
FHP  
CABLE MANAGEMENT  
WARNING: Make sure your cables do not run through a pinch  
point.  
1. Route power/audio/video cables against column, allowing suf-  
ficient slack in cables for extension and avoiding pinch points.  
2. Install top cable cover over cables (see Figure 5).  
3. Measure distance of remaining exposed cables and, using a  
saw or appropriate tool, cut lower cable cover to length.  
4. Install bottom cable cover over remaining exposed cables.  
ADJUSTMENTS  
CAUTION: Overtightening adjustment will cause excessive  
wear.  
Rotational Tilt, Pitch, and Roll Adjustment  
1. If necessary, use a Phillips screwdriver to tighten or loosen the  
Phillips pan head screw (see “DRAWINGS” on page 3).  
2. Check for desired tension.  
3. Repeat Steps 1 and 2 until desired tension is obtained.  
Figure 5. Install Cable Cover  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
FHP  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
FHP  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Switch F1DG 102Duk User Manual
Blomberg Washer WMF 8428 A User Manual
Bosch Appliances Washer WFMC6401UC User Manual
Breville Toaster BOV800 User Manual
Bushnell Indoor Furnishings 100400 User Manual
Canon Camera Lens EF 16 User Manual
Carcomm Car Speaker CMPC 98 HTC P4350 User Manual
Casablanca Fan Company Fan C19546K User Manual
Casio Watch GQ 200 User Manual
Cecilware Coffeemaker FE 100G User Manual