1. BEFORE YOU BEGIN  
What is included  
1 x Hurricane1300  
1 x FC-T wired timer remote  
1 x Warranty Card  
1 x User Manual  
Unpacking Instructions  
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that  
all parts are present, and have been received in good condition. Notify the shipper immediately and  
retain packing material for inspection if any parts appear damaged from shipping or the carton itself  
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture  
must be returned to the factory, it is important that the fixture be returned in the original factory box  
and packing.  
AC Power  
To determine the power requirements for a particular fixture, see the label affixed to the back plate of  
the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average  
current draw under normal conditions. All fixtures must be powered directly off a switched circuit and  
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer  
channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the  
source voltage matches the fixture’s requirement. Check the fixture or device carefully to make sure  
that if a voltage selection switch exists that it is set to the correct line voltage you will use.  
Hurricane™ 1300 User Manual  
3
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Instructions  
Please read these instructions carefully, which includes important  
information about the installation, usage and maintenance of this  
product.  
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that  
they also receive this instruction booklet.  
Always make sure that you are connecting to the proper voltage, and that the line voltage you are  
connecting to is not higher than that stated on the decal or rear panel of the fixture.  
This product is intended for indoor use only! (If applicable)  
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no  
flammable materials close to the unit while operating.  
The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent  
surfaces. Be sure that no ventilation slots are blocked.  
Always disconnect from power source before servicing or replacing lamp or fuse and be sure to  
replace with same lamp source.  
Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use  
its carrying handles.  
Maximum ambient temperature (Ta) is 104°F (40°C). Do not operate fixture at temperatures higher  
than this.  
In the event of a serious operating problem, stop using the unit immediately. Never try to repair the  
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please  
contact the nearest authorized technical assistance center. Always use the same type spare parts.  
Never connect the device to a dimmer pack.  
Make sure the power cord is never crimped or damaged.  
Never disconnect the power cord by pulling or tugging on the cord.  
Avoid direct eye exposure to the light source while it is on.  
Caution!  
There are no user serviceable parts inside the unit. Do not open the housing or  
attempt any repairs yourself. In the unlikely event your unit may require service,  
please contact CHAUVET at: 954-929-1115.  
Hurricane™ 1300 User Manual  
4
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. INTRODUCTION  
Features  
Output: 20,000cfm  
3.3L tank capacity  
Uses 1L every 8min (continuous use at full output)  
5 minute heat up  
Manual fog button  
Low fluid indicator and auto shut down  
Wired timer remote included  
Water-based fogger  
Product Dimensions  
Hurricane™ 1300 User Manual  
5
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Overview  
Hanging  
bracket  
Safety  
eyebolt  
Fluid  
container  
Handle  
Tilt  
Adjustment  
knob  
Heater  
Nozzle  
Low Fluid  
indicator  
Manual  
controller  
Fluid level  
indicator  
Power  
switch  
Fuse holder  
Power input  
(hardwired)  
Manual Fog  
button  
Wireless  
Controller  
Hurricane™ 1300 User Manual  
6
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disconnect the power cord before replacing a fuse and always  
replace with the same type fuse.  
Fuse Replacement  
With a flat head screwdriver wedge the fuse  
holder out of its housing. Remove the damaged  
fuse from its holder and replace with exact  
same type fuse. Insert the fuse holder back in  
its place and reconnect power.  
The fuse is located  
inside this  
compartment.  
Remove using a flat  
head screwdriver.  
Mounting  
ORIENTATION  
This fixture should only be mounted/used on a flat surface. This fixture may not be tilted.  
RIGGING  
It is important never to obstruct the vents pathways. Mount the fixture using, a suitable “C” or “O” type  
clamp.  
When selecting installation location, take into consideration the fluid reservoir access and routine  
maintenance.  
Safety cables must always be used, utilizing the provided safety eye bolt.  
Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature  
changes or restricted ventilation.  
Hanging Clamp  
Angled Down  
Angled Up  
Note!  
Clamp is sold separately.  
Hurricane™ 1300 User Manual  
7
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. OPERATING INSTRUCTIONS  
Operation  
Manual Remote Operation (FC-M) (Optional)  
1. Plug in the fog machine to power and turn the power switch to the fixture on.  
2. Plug in the wired manual remote to the Manual Controller socket on the rear of the fog machine.  
3. Press the single button located on the remote to trigger the fog output.  
Note: The button is momentary, which means that the fog machine will only output while the  
button is pressed. Once the button is released, the fog will stop outputting.  
Timer Remote Operation (FC-T) (Standard)  
This mode will allow you to control the fogger manually, set the fog machine to run continuously, or to set the fog  
machine to run off bursts with adjustable interval and duration settings.  
1. Plug in the fog machine to power and turn the power switch to the fixture on.  
2. Plug in the timer remote to the Manual Controller socket on the rear of the fog machine.  
3. Press the TIMER ON/OFF button on the timer remote. The LED above the button should light, indicating  
activation of function.  
4. You may now set the INTERVAL & DURATION adjustment knobs to the desired position.  
Note: The INTERVAL is the time in between bursts of fog.  
Note: The DURATION is the time that the fog machine will run during the burst.  
Duration  
Interval  
Adjustment  
Adjustment  
Timer LED  
Indicator  
Manual  
Momentary  
LED  
Manual/Power LED  
Indicator  
Manual control  
momentary button  
Timer latching  
button  
Continuous  
latching button  
Hurricane™ 1300 User Manual  
8
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wireless Controller (FC-W) (Optional)  
This mode will allow you to control the fogger using the optional wireless controller. This consists of the  
transmitter and the receiver. You may control up to 4 independent fog machines or many more if you run them  
simultaneously. See the below instructions on setting up your fogger to operate with the FC-W.  
1. Plug the wires receiver into the fog machine 5-pin port labeled “Wireless Controller”.  
2. There are 4 buttons on the wireless remote transmitter which act as triggers. Each button can be assigned to a  
different fog machine. You may only choose 1 dipswitch on each receiver. See the below configuration for  
setting the receivers to operate with the transmitter remote.  
Mode  
Dipswitches  
CH1  
1 = On, 2-4 = Off  
CH2  
CH3  
CH4  
2 = On, 1,3,4 = Off  
3 = On, 1,2,4 = Off  
4 = On, 1,2,3 = Off  
3. Press the fog button, and the fog machine will output fog momentarily for as long as you hold down the button.  
LED indicator  
LED indicator  
(ready)  
(heating)  
Dipswitches  
Wireless  
Transmitter  
Fog  
Triggers  
Wireless  
Receiver  
Hurricane™ 1300 User Manual  
9
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hurricane™ 1300 General Troubleshooting  
Symptom  
No Power  
Solution(s)  
Check mains power.  
Check external fuse.  
Check internal fuse.  
Check fluid level.  
No fog output  
Check remote.  
If using wireless, check batteries.  
If using wireless, check dipswitches on receiver.  
Possible electrical short. Contact Chauvet or a Chauvet Dealer/distributor for  
further instruction.  
Breaker/Fuse keeps  
blowing  
Low fog output  
Run a cleaning solution through the fog machine.  
Check that the fog machine is plugged into the correct voltage.  
Check to replace the external fuse.  
Fog machine is not  
heating up  
Check to replace the internal fuse.  
Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor for further  
instruction.  
Remote does not  
work  
Make sure connector is firmly connected to device.  
Try using another controller. Possible bad controller.  
Check the internal fuse.  
Check the external fuse.  
Fluid indicator states Try resetting the fog machine by turning the power off, and then on again.  
no fog, but the  
container if full.  
Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor for further  
instruction.  
If you still have a problem after trying the above solutions, please contact CHAUVET Technical  
Support at the location listed below.  
Contact Us  
World Wide  
General Information  
CHAUVET  
3000 North 29th Court  
Hollywood, FL 33020  
voice: 954.929.1115  
fax:  
954.929.5560  
toll free: 800.762.1084  
Technical Support  
CHAUVET  
3000 North 29th Court  
Hollywood, FL 33020  
voice: 954.929.1115 (Press 4)  
fax:  
954.929.5560 (Attention: Service)  
World Wide Web  
Hurricane™ 1300 User Manual  
10  
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. APPENDIX  
General Maintenance  
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage  
and environment are contributing factors in determining frequency. As a general rule, fixtures should  
be cleaned at least twice a month. Dust build up reduces light output performance and can cause  
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off  
fixture before conducting maintenance.  
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust  
collected on external vents and internal components. Clean all glass when the fixture is cold with a  
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply  
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical  
surfaces until they are free of haze and lint.  
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to  
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:  
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s  
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean  
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.  
Returns Procedure  
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.  
Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #).  
Products returned without a RMA # will be refused. Call CHAUVET and request a RMA # prior to  
shipping the fixture. Be prepared to provide the model number, serial number and a brief description  
of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from  
inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own  
discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is  
always a safe method to use.  
Note:  
If you are given a RMA #, please include the following information on a piece of  
paper inside the box:  
1) Your name  
2) Your address  
3) Your phone number  
4) The RMA #  
5) A brief description of the symptoms  
Claims  
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be  
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and  
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim  
for items such as missing component/part, damage not related to shipping, and concealed damage,  
must be made within seven (7) days of receiving merchandise.  
Hurricane™ 1300 User Manual  
11  
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Blow-out Diagram.  
7
6
2
3
1
4
8
9
Description  
Master PCB  
Heater  
Part Number  
P170-F3MSPCB  
P120-HT13  
1
2
3
4
5
6
7
8
9
Pump  
P200-F3PUMP  
P170-F3FLC  
Fluid container  
Fluid sensor (not shown)  
Thermal switch 115° Celsius  
Bracket Knob  
Fuse holder  
Manual fog button  
P170-F1FLOS  
P170-THEF11  
P111-F3BKNOB  
P170-FUSEHOL  
P111-F3FOGB  
P170-FUSE013  
10 Fuse 13A 250V (not shown)  
11 Fluid filter (not shown)  
12 Fluid hose with fittings (not shown)  
13 Copper tubing with fittings (not shown)  
P110-F1FLAS  
P170-F3RUB  
P170-F3COP  
Hurricane™ 1300 User Manual  
12  
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connections Drawing  
In the event that any part(s) may need to be replaced/repaired, you may use the below diagram  
to assist in this operation.  
Warning: All repairs should only be performed by Authorized Service Personnel.  
Hurricane™ 1300 User Manual  
13  
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specifications  
WEIGHT & DIMENSIONS  
Length .............................................................................................................................. 16.5 in (419 mm)  
Width................................................................................................................................ 12.3 in (313 mm)  
Height............................................................................................................................... 12.1 in (306 mm)  
Weight...................................................................................................................................21 lbs (9.5 kg)  
POWER  
AC Power.....................................................................................................120V 60Hz AC or 230V 50Hz  
Fuse .............................................................................................................................................13A 250V  
Power Consumption .................................................................................... 1,328W (11.2A) max at 120V  
Inrush Power...................................................................................................................... (11.2A) at 120V  
Power Factor........................................................................................................................... 0.99 at 120V  
Fuse ...............................................................................................................................................7A 250V  
Power Consumption .......................................................................................1,325W (5.8A) max at 230V  
Inrush Power...................................................................................................................... (1.83A) at 230V  
Power Factor........................................................................................................................... 0.99 at 230V  
THERMAL  
Maximum ambient temperature .............................................................................................104°F (40°C)  
CONTROL & PROGRAMMING  
Data input............................................................................................5-pin & ground DIN5 female socket  
Data pin configuration......pin1(LED), pin2(control), pin3(+5V), pin4(ground), pin5(none), ground(none)  
ORDERING INFORMATION  
Hurricane1300...............................................................................................................................F1300  
Wired manual remote (optional).........................................................................................................FC-M  
Wired timer remote (included).............................................................................................................FC-T  
Wireless manual remote (optional) ....................................................................................................FC-W  
SPARE PARTS ORDERING INFORMATION  
Master PCB.......................................................................................................................P170-F3MSPCB  
Heater ...................................................................................................................................... 1P20-HT13  
Pump................................................................................................................................... P200-F3PUMP  
Fluid container ........................................................................................................................P170-F3FLC  
Fluid sensor ........................................................................................................................ P170-F1FLOS  
Thermal switch......................................................................................................................P170-THEF11  
Bracket knob.....................................................................................................................P111-F3BKNOB  
Fuse holder ......................................................................................................................P170-FUSEHOL  
Manual fog button................................................................................................................P111-F3FOGB  
WARRANTY INFORMATION  
Warranty..................................................................................................................1-year limited warranty  
Hurricane™ 1300 User Manual  
14  
3/26/2009 3:18 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Decker Power Hammer BPHR223K User Manual
Bose Speaker System 15 10 User Manual
Bravetti Microwave Oven K5345H User Manual
Broil King Smoker 911770 4000 SERIES User Manual
Brother All in One Printer MFC J625W User Manual
Bush Hog Compact Excavator 665H User Manual
Bushnell Indoor Furnishings 100400 User Manual
Casio Watch HS 50W User Manual
Century Car Seat 44892L User Manual
Chicago Electric Portable Generator 67561 User Manual